SE Const. Circle Mahi Project Banswara
SE Const. Circle Mahi Project Mahi Colony Banswara
Supply, Installation and Maintenance of SCADA system for Mahi Sagar Dam, District- Banswara, Rajasthan
2020_WRDAS_177468_1
02/2019-20 SE MAHI Banswara
Open Tender
Surveillance Equipments
Item Rate
270 days
Banswara
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,000
EE Dam Dn. I Mahi Project Banswara
Exempted
Jaipur
2 Nov 2020
15 Feb 2020
17 Jul 2020
15 Feb 2020
17 Jul 2020
15 Feb 2020
24 Feb 2020
Supply of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up of minimum2 hours, 7” or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification. (Inclusive all taxes)
Supply of Shaft Encoder based rotary position sensor with digital Display Type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU as per technical specifications.(Inclusive all taxes)
Supply of 3 Phase VFD Starter panel of 7.5KW for each motor of Dam gates which shall consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Indicator complete as per technical specifications.(Inclusive all taxes)
Supply of LTE Surveillance IP based 3G/4G Bullet Camera with Sim Card Slot, 2 Mega Pixel 2 OR4 Array/ 72 LED Colour camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24-hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, for monitoring the gates operation at dam & head regulators complete as per Technical Specifications.(Inclusive all taxes)
Supply of Pan Tilt Zoom (PTZ) 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP based (DIGITAL) camera, 500 mtrs. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling required for monitoring. As per technical specifications.(Inclusive all taxes)
Supply of Water Level transmitter non-contact RADAR type having 70m range for measuring upstream dam level including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.(Inclusive all taxes)
Supply of Water Level transmitter non-contact RADAR type having 35m range for measuring upstream level & downstream discharge of Dam including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.(Inclusive all taxes)
Supply of Water Level transmitter non-contact RADAR type having 20m range for measuring upstream level of Head regulators of Kagdi pick up weir, LMC & RMC including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.(Inclusive all taxes)
Supply of Water Level transmitter non-contact Ultrasonic type having 10m range for measuring upstream level & downstream discharge of head regulator of LMC, RMC & Kagdi Pickup Weir. Including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.(Inclusive all taxes)
Supply of Ultrasonic clamp on type flow meter for pipe discharge measurement of 1500mm MS pipe, including GPRS/GSM modem & SIM along with required necessary mounting hardware complete as per technical specifications. (Inclusive all taxes)
Supply of 1KVA UPS with Batteries for 2 hours power backup to Flow meter & GPRS/GSM modem fitted in MS cabinet along with modem, flow transmitter, Surge protection, MCB & lightning arrestors and other accessories as per technical specifications.(Inclusive all taxes)
Monitoring station for inflow discharge measurement to Mahi Bajaj Sagar Dam
Supply of Water Level transmitter non-contact RADAR type having 15m range for measurement discharge of river on U/S of Mahi Bajaj Sagar dam, which is includes all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.(Inclusive all taxes)
Supply of Data logger of 2 channel input type with GPRS/GSM telemetry for data logging & transmission of real time data from level transmitters at river in the upstream of dam, to SCADA system, with all relevant mounting accessories. As per technical specifications.(Inclusive all taxes)
Supply of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply to monitoring station, as per technical specifications. (Inclusive all taxes)
Flood Alarming Station’s
Supply of intelligent field controller/ RTU with software development with metallic front door opening cabinet, fitted with GPRS/GSM modem, siren at Pipalkhunt bridge, sabla bridge, and Narwali Bridge along with industrial grade electrical fitting & cabling with suitable conduits complete, as per technical specification.(Inclusive all taxes)
Supply of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply to Flood alarming station technical specifications.(Inclusive all taxes)
Mahi Dam Control Room Equipment’s
Supply of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. All the Electrical fittings will be Industrial type. Including suitable switch mode power supply (SMPS) ,12” display & interconnection with related remote PLC/RTU’s, complete as per technical specification.(Inclusive all taxes)
Supply, engineering and development of customized SCADA software for complete System and head regulators at Kagdi Pickup Weir, LMC & RMC system with life time licensed version as per technical specifications.(Inclusive all taxes)
Supply of Master server which includes Server with server Rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications.(Inclusive all taxes)
NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format. With HDD along with dedicated server with sufficient Hard Drive to have memory of at least 30 days as per technical Specifications.(Inclusive all taxes)
Supply of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 colour printer as per technical specifications.(Inclusive all taxes)
Supply of 80” LED Display/ Video wall DLP based System for monitoring of SCADA & surveillance system at Control Room as per technical specifications. (Inclusive all taxes)
Supply of online 3 KVA UPS with Battery system for power back up of dam control room equipment’s including all necessary cabling & electrical fittings complete as per the technical specifications. (Inclusive all taxes)
Supply of laptops & internet connection (4G/3G) along with Client SCADA software for remote viewing & monitoring of Dam automation as per technical specifications.(Inclusive all taxes)
Supply of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing along with accessories complete as per technical specifications.(Inclusive all taxes)
Supply of Air cooled Cassette Type Air conditioners complete with indoor (IDU), Outdoor unit (ODU), surface/concealed copper refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDU to ODU), copper power cable upto 10 Mtr (IDU to ODU), R-22 Refrigerant wireless remote, drain pump, suitable for 400/230V + 10% of 50Hz, 1/3 phase AC supply capable of performing cooling, dehumidification, air circulation, filtration & ventilation of following capacity with scroll/ reciprocating/ rotary compressor as specified with requisite furniture for establishment of Control rooms at Mahi Sagar Dam & kagdi pick weir along with necessary electrical fittings. E271802 (2Ton) (Excluding Labour Charges)
Kagdi Control Room
Supply of Master server which includes sever with sever rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to client SCADA System complete as per technical specifications with Work station ( overall height of work station partition 12mm size of drawer unit (widthXdepthXheight)-390X440X147mm), depth table top-750mm,length of table top 1200mm. (inclusive all taxes)
Supply of online 3 KVA UPS with Battery system for power back up of Kagdi control room equipment’s including all necessary cabling & electrical fittings complete as per the technical specifications. (Inclusive all taxes)
Supply, installation, testing and commissioning of 55” LED Display system for monitoring of SCADA & surveillance system at Kagdi Control Room, Mahi Rest house & Divisional office as per technical specifications. (Inclusive all taxes)
Installation
Installation, testing & Commissioning of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up of minimum 2 hours, 7 inches or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification.
Installation, testing & commissioning of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU, datalogger as per technical specifications.
Installation, testing & commissioning of 3 Phase VFD Starter panel of 7.5KW for each motor of Dam gates which consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Indicator complete as per technical specifications.
Installation, testing and Commissioning & integration of LTE Surveillance IP based 3G/4G Bullet Camera with Sim Card Slot, 2 Mega Pixel 2 OR4 Array/ 72 LED Colour camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24-hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, communication with NVR located at Master control room for monitoring the gates operation complete as per Technical Specifications.
Installation, Testing & Commissioning & integration with NVR Located at Master Control Room of Pan Tilt Zoom (PTZ) Cameras, 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP (DIGITAL) Camera, 500 mtrs. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling & conducting required for dam monitoring. As per technical specifications.
Installation, testing & Commissioning of Water Level transmitter non-contact RADAR type having 70m range for measuring Upstream Dam level. including all necessary cabling, conduits, electrical fitting & mast complete, as per technical specifications.
Installation, testing & Commissioning of Water Level transmitter non-contact RADAR type having 35m range for measuring Upstream level & downstream discharge of Dam. Including all necessary cabling, conduits, electrical fitting & mast complete, as per technical specifications.
Installation, testing & Commissioning of Water Level transmitter non-contact RADAR type having 20m range for measuring Upstream level of Head Regulators of kagdi pick up weir, LMC & RMC. Including all necessary cabling, conduits, electrical fitting & mast complete, as per technical specifications.
Installation, testing & Commissioning of Water Level transmitter non-contact Ultrasonic type having 10m range for measuring downstream discharge of head regulator of LMC, RMC & Kagdi pickup weir. Including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.
Installation, testing, Commissioning of Ultrasonic clamp on type flowmeter for pipe discharge measurement of 1500mm MS pipe, including GPRS/GSM modem & SIM along with associated Civil works, laying of signal cables, providing necessary fixtures for mounting flow sensors & required necessary mounting hardware as per technical specifications.
Installation testing and commissioning of 1KVA UPS with Batteries for 2 hours power backup to Flowmeter & GPRS/GSM modem fitted in MS cabinet along with modem, flow transmitter, Surge protection, MCB & lightning arrestors, cabling and other accessories as per technical specifications.
Monitoring station for inflow discharge measurement to Mahi Bajaj Sagar Dam
Installation testing and commissioning of Water Level transmitter non-contact RADAR type having 15m range for measuring discharge of river in the upstream of Mahi Bajaj Sagar dam, which includes all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications.
Installation testing and commissioning of Data logger of 2 channel input type with GPRS/GSM telemetry for data logging & transmission of real time data from level transmitters at river in the upstream of dam, to SCADA system, with all relevant mounting accessories, NEMA 4X housing enclosures. As per technical specifications.
Installation testing and commissioning of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply to data logger, as per technical specifications.
construction of 1m high wire fencing of (3m x3m plot size) along with 1mX1m MS gates with locking arrangements for external protection of Monitoring station for inflow discharge measurement all respect including material as per drawing.
Flood Alarming Station’s
Installation testing and commissioning of intelligent field controller/ RTU with software development with metallic front door opening cabinet, fitted with GPRS/GSM modem, siren at Pipalkhunt bridge, sabla bridge, and Narwali Bridge along with industrial grade electrical fitting & cabling with suitable conduits complete, as per technical specification.
Installation testing and commissioning of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing un interrupted power supply to Flood alarming station as per technical specifications.
construction of 1m high wire fencing of (3m x3m plot size) along with 1mX1m MS gates with locking arrangements for external protection of Flood alarming station complete in all respect including material as per drawing.
Barrage Control Room Equipment’s
Installation, Testing & Commissioning of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. Including suitable switch mode power supply (SMPS) ,12” display & cabling with Industrial grade type electrical fittings for related remote PLC/RTU’s, as per technical specification.
Installation, testing & Commissioning of customized SCADA software for complete Dam automation and specified canal head regulators with life time licensed version as per technical specifications
Installation, Testing & Commissioning of Master server with SCADA Software which includes Server with server Rack and industrial grade PC with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications
Installation, testing & commissioning of NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format. With HDD along with dedicated Hard Drive to have memory of at least 30 days as per technical Specifications.
Installation, Testing & Commissioning of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 colour printer as per technical specifications
Installation, Testing & Commissioning 80” LED Display/ Video wall DLP based System for monitoring of SCADA & surveillance system at Control Room as per technical specifications
Charges for high speed synchronous internet connection (min. 8 mbps upload and download speed) & Static IP for Five years.
Installation, Testing & Commissioning of Online 3 KVA UPS with Battery system for power back up of dam control room equipment’s as per the technical specifications
Installation, Testing and Commissioning of Diesel Generator Set 10.0 KVA with 04 Earth Pits for earthing, Starter Panel, Energy meter & cabling Complete in all respects as per technical specifications.
Installation, Testing & Commissioning of Air cooled Cassette Type Air conditioners complete with indoor (IDU), Outdoor unit (ODU), surface/concealed copper refrigerant piping with insulation (EP foam pipe section) upto 10 Mtr (IDU to ODU), copper power cable upto 10 Mtr (IDU to ODU), R-22 Refrigerant wireless remote, drain pump, suitable for 400/230V + 10% of 50Hz, 1/3 phase AC supply capable of performing cooling, dehumidification, air circulation, filtration & ventilation of following capacity with scroll/ reciprocating/ rotary compressor as specified with requisite furniture for establishment of Control rooms at Mahi Sagar Dam & kagdi pick weir along with necessary electrical fittings. ( Labour Charge) E271802 (2Ton)
Kagdi Control Room
Installation, Testing & Commissioning of master server with SCADA software with work station enabled for LMC, RMC and Kagdi pickup weir operations, which includes Server rack and industrial grade PC with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to client SCADA System complete as per technical specifications.
Installation, Testing & Commissioning of online 3 KVA UPS with Battery system for power back up of dam control room equipment’s including all necessary cabling & electrical fittings complete as per the technical specifications
Charges for high speed synchronous internet broadband connection (min. 8 mbps upload and download speed) & static IP for Five years at Kagdi Control room.
Five Years Operation & Maintenance and Comprehensive Warranty for Mahi Bajaj Sagar Dam, Kagdi pickup weir & head regulators SCADA based system as per Price schedule after final acceptance of SCADA & Surveillance system. This includes replacement of material & consumable as & when required at bidders’ cost. The cost of Communication for GPRS & SIM charges for data transmission, maintenance and other related charges. Minimum one Service Engineer shall be placed at each Control room for Operation of SCADA & Surveillance system.
Training of the purchaser's personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC/RTU & SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies.
Indexel Engineering Pvt. Ltd.
YOKOGAWA INDIA LIMITED
M/S GA INFRA PVT LTD
bips systems ltd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .