Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 LAccepted-Finance RZ 14D 2ND FLOOR GALI NO 5 SYNDICATE ENCLAVE NEAR DABRI MORE NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L1 | Accepted-Finance Lowest bidder | |
| 2 | L2₹2.4 L+₹2,550 (1.06%)Rejected-Finance RZ 40 PALAM VIHAR DWARKA SECTOR 6 NEW DELHI 75 | NEW DELHI | DELHI | 75 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹2.4 L+₹3,970 (1.66%)Rejected-Finance WZ 831 NANGAL RAYA PANKHA ROAD NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹2.5 L+₹6,380 (2.66%)Rejected-Finance C 26 NEW MULTAN NAGAR DELHI NORTH WEST DELHI DELHI 110056 | NORTH WEST DELHI | DELHI | 110056 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹2.5 L+₹7,060 (2.94%)Rejected-Finance WZ 109 PLOT NO 327 CHAND NAGAR NEW DELHI | L5 | Rejected-Finance Other than lowest bidder |
| Sl No | Description | Qty | Unit | DUBEY ENTERPRISES L1 | Tushar engineers L3 | Suman Uni Controllers L5 | sudarshan trading co. L4 | BUSINESS TEK INDIA L2 | R.K.TRADING CO. L6 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | (a) Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc. keeping
the AC unit in satisfactory working condition after necessary servicing as requiredand refixing the same in existing position complete all as specified and as directed, (Qty-80 No)
(b) All as per srl item No 1.00 here-in-before but window type AC of capacity 1.5/
2 TR complete all as specified and as directed, (Qty-30 Nos)
(c) S & F in replacement Running capacitor 36+6 MFD complete all as specified and as directed (Qty-08
(d) S & F in replacement Running capacitor 45+5 MFD complete all as specified and as directed (Qty-08
(e) S & F in replacement Running capacitor 50+6 MFD complete all as specified and as directed, (Qty- 12
(f) S & F in replacement Starting capacitor 80-100 MFD complete all as specified and as directed (Qty-10
(g) S & F in replacement Starting capacitor 100-120 MFD complete all as specifiedand as directed (Qty- 10
(h) S & F in replacement Starting Relay 1622 complete all as specified and as directed . (Qty- 12 )
(j) S & F in replacement Starting Relay 2000 complete all as specified and as directed (Qty- 10 Nos)
(k) S & F in replacement Thermostat switch 2059/2064/205 complete all as specified and as directed (Qty-08 Nos)
(l) Material & Labour for rectifying electrical wiring fault of any capacity & type of
AC and make them functional and also carry out the required repair complete all
as specified and as directed (Qty- 25 Nos)
(m) M & L for Carryout the pressure test with nitrogen gas of refrigeration system
detecting leakage including soldering and brazing of leaking copper tubing for any
type of ACs complete all as specified and directed (Qty- 46 Nos)
(n) M & L for complete topping up the refrigerant gas ( R22/R32/R410A) in split/
window type 1.5 TR & testing and commissioning complete in satisfactory working
condition complete all as specified & as directed. (Qty- 24 Nos)
(o) M & L for complete topping up the refrigerant gas ( R22/R32/R410A) in split/
window type 2.0 TR & testing and commissioning complete in satisfactory working
condition complete all as specified & as directed. (Qty- 22 Nos)
(p) Taking down, repairing and re-fixing PCB, suitable for inverter type, split type
AC of any capacity and model complete all as specified and as directed.(Qty-08 Nos)
(q) Taking down, repairing and re-fixing PCB, suitable for split type AC of any
capacity and model complete all as specified and directed. (Qty- 12 Nos) | 1 | Job | 2,39,800 ₹2,39,800 Lowest | 2,43,770 ₹2,43,770 | 2,46,860 ₹2,46,860 | 2,46,180 ₹2,46,180 | 2,42,350 ₹2,42,350 | 2,54,231 ₹2,54,231 |
Tender Value
Refer Docs
Closing Date
16 Aug 2025, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR MAINTENANCE OF WINDOW SPLIT ACS INSTALLED AT CRO OFFICE DCN PALAM RAINBOW MESS ALL MES OFFICES AUDIT OFFICES AND VARIOUS CERTAIN UNITS UNDER GE U P M DELHI CANTT
2025_MES_725128_1
GE(U)/PM/3011/B/JO/58/E3
Limited
Miscellaneous Works
Piece-work
Delhi CAntt
PLEASE REFER NOTICE INVITING QUOTATION
1 document required · 1 mandatory
₹0
Exempted
20 Aug 2025
8 Aug 2025
18 Aug 2025
9 Aug 2025
16 Aug 2025
9 Aug 2025
Amount
(a) Taking down for servicing of split type AC 1.5/2 TR Capacity including cleaning of cooling coil, air filters/plasma filters etc, (Indoor unit), condenser, compressors fan motor etc,(Out door unit) with vacuum cleaner or cleaning solution including checking the serviceability of electrical/electronic circuits relays, wiring kit, thermostat switches knobs, Remote control unit including PCB, fan, blower, etc. keeping the AC unit in satisfactory working condition after necessary servicing as requiredand refixing the same in existing position complete all as specified and as directed, (Qty-80 No) (b) All as per srl item No 1.00 here-in-before but window type AC of capacity 1.5/ 2 TR complete all as specified and as directed, (Qty-30 Nos) (c) S & F in replacement Running capacitor 36+6 MFD complete all as specified and as directed (Qty-08 (d) S & F in replacement Running capacitor 45+5 MFD complete all as specified and as directed (Qty-08 (e) S & F in replacement Running capacitor 50+6 MFD complete all as specified and as directed, (Qty- 12 (f) S & F in replacement Starting capacitor 80-100 MFD complete all as specified and as directed (Qty-10 (g) S & F in replacement Starting capacitor 100-120 MFD complete all as specifiedand as directed (Qty- 10 (h) S & F in replacement Starting Relay 1622 complete all as specified and as directed . (Qty- 12 ) (j) S & F in replacement Starting Relay 2000 complete all as specified and as directed (Qty- 10 Nos) (k) S & F in replacement Thermostat switch 2059/2064/205 complete all as specified and as directed (Qty-08 Nos) (l) Material & Labour for rectifying electrical wiring fault of any capacity & type of AC and make them functional and also carry out the required repair complete all as specified and as directed (Qty- 25 Nos) (m) M & L for Carryout the pressure test with nitrogen gas of refrigeration system detecting leakage including soldering and brazing of leaking copper tubing for any type of ACs complete all as specified and directed (Qty- 46 Nos) (n) M & L for complete topping up the refrigerant gas ( R22/R32/R410A) in split/ window type 1.5 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. (Qty- 24 Nos) (o) M & L for complete topping up the refrigerant gas ( R22/R32/R410A) in split/ window type 2.0 TR & testing and commissioning complete in satisfactory working condition complete all as specified & as directed. (Qty- 22 Nos) (p) Taking down, repairing and re-fixing PCB, suitable for inverter type, split type AC of any capacity and model complete all as specified and as directed.(Qty-08 Nos) (q) Taking down, repairing and re-fixing PCB, suitable for split type AC of any capacity and model complete all as specified and directed. (Qty- 12 Nos)
BUSINESS TEK INDIA (BID ID -3395658)
Tushar engineers (BID ID -3390038)
sudarshan trading co. (BID ID -3390555)
Suman Uni Controllers (BID ID -3390061)
R.K.TRADING CO. (BID ID -3396069)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
finance_811650.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .