Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.4 LAccepted-AOC | L1 | Accepted-AOC FOUND LOWEST | |
| 2 | L2₹42.8 L+₹1.0 L (2.43%)Rejected-AOC | L2 | Rejected-AOC NOT LOWEST | |
| 3 | L3₹46.8 L+₹5.0 L (12.0%)Rejected-AOC | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹43.1 L
EMD Value
₹86,200
Closing Date
7 Apr 2022, 6:00 pmClosed
SHRI MAHAVIR SINGH, IDSE, GE (SOUTH)
GARRISON ENGINEER (SOUTH), MUDFORT, SECUNDERABD
SPL REPAIRS TO GUEST ROOM OF OFFR MESS AND SEEPAGE OF WALL OF BLDG NO P-54, INCL PROVN OF CERTAIN SECURITY ARNGS, OPEN SHED, GALVANIZED SHEET WITHOUT WALL, ERECTION OF 10 X PRECAST CONCRETE BOARDS UNDER AGE B/R (S) NO. I,II,AGE E/M (S) OF GE (S) SEC
2022_MES_513065_1
GE (S)/SEC/TOKEN - 71 OF 2021 - 22
Open Tender
Civil Works
Item Rate
240 days
SECUNDERABD
For Enlisted contractors class D and above category a (i) and b (i) and for unenlisted contractors meeting the eligibility criteria of above class and category for along eligible class with EMD
5 documents required · 5 mandatory
₹500
GE SOUTH, MUDFORT, SECUNDERABAD
₹86,200
Yes
18 Jun 2022
10 Mar 2022
9 Apr 2022
10 Mar 2022
7 Apr 2022
25 Mar 2022
11 Mar 2022 - 24 Mar 2022
Amount
Excavating in post holes (or similar holes) each n exc 0.5 cu.m, getting out, in hard dense soil all as specified and directed.
M&L for Hard core of gauge not exc 63mm deposited, spread and leveled in layers not exc. 15 cm thick, watered and rammed to a true surface of 100mm thick with broken/stone/boulders.
Excavation in trenches, not exceeding 1.5 m wide or not exceeding 10 sq m on plan and not exceeding 1.5 m in depth for foundation of manhole etc and getting out as in soft/loose soil complete all as specified & directed.
Returning , filling in hard/dense soil including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick , including watering ,ramming complete all as specified and as directed .
Removing of soil to distance n.exc 50 mtr and depositing at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed .
Material and Labour for PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in foundation filling complete all as specified and as directed .
M & L for PCC (1:2:4) type B-2 (using 40 mm graded stone aggregate) as in Foundation filling,mass concrete complete all as specified and as directed.
Use and waste of Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed.
Material & Labour for PCC 1:3:6 type C2 using 40mm graded aggregate as in foundation and mass concrete all as specifed and directed.
Material & Labour for providing, cement concreteusing PCC 1:2:4 type B1 using 20mm graded aggregate in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item , water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed.
Supply only water proofing compound ISI marked all as specifed and directed.
Taking down chowkats of frames with shutters (without taking of shutters from the frame) n.exc 1.50 Sqm each all as specified and directed.
S & F factory made solid panel PVC door shutter 30mm thick (style), consisting of frame, made out of MS tubes for top and bottom rails MS frame shall be covered with heat moulded plain colour PVC, 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for to rail & bottom rail, paneling of plain of colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed to getter with solvent cement, s & F in the frame at site as per specification and drawing for item No. 08080 on page No.l 156 of SSR 2010 (Part-II) all as specified and directed.
S & F solid PVC door frame of size 50 x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tales complete all as specified and directed.
S & F Alluminium anodised barrel tower bolts 150mm of extruded section and fixed all as specified and directed.
S&F Butt hinges of 100 mm extruded aluminium alloy with galvanised mild steel hinge pin anodised and fixed all as specified and directed.
S & F extruded aluminium alloy handles, fabricated type anodised 125mm size complete all as specified and directed.
S & F 60 cm long brass chromium plated towel rail 20mm dia with two brackets fixed in repairs all as specified and directed
S & F Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed.
Supply & Fix angle iron posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165
S&F Mild steel bolts purpose made with hexagonal or square head one end and screwed the other, or screwed both ends; each screwed end to be fitted with washers and one hexagonal or square nut. exc 30cm long.
S & F for mild steel plates (plain or chequired) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410-W (Gde E-250) Quality -A all as specifed and directed.
S&F for roof trusses (framed), trussed, purlines, heavy brackets framing (beam, tee, angle, channel or flats section) including distance pieces, cleat etc conforming to Fe-410 (Gde-E250) quality -A all as specifed and directed.
S&F Steel work in tubular column/trusses including special shaped washer, etc complete using ERW tubes conforming to IS 1161-1979 grade St.-240 all as specifed and directed.
S&F pre painted galvalume aluminium zinc coating GI based steel sheet trapezoidal profile 0.50mm thick of an colour having tensile strength of 550Mpa as in roof coverings/cladding to wall,fixed with self tapping screws as specified.
M&L for PCC (1:2:4) type B-2 (using 40mm graded aggregates) as in floor 100mm thick all as specified and directed.
M&L for PCC (1:3:6) type D-2 (using 40mm graded aggregates) as in sub base 75mm thick all as specified.
M & L for 25 mm thick PCC (1:2:4) ype B0 by using 12.50 mm graded stone aggregate as in sub base, roof, where required over slabs including necessary form work and finishing the exposed surfaces fair even without using extra cement complete all as specified and as directed.
M&L Glass dividing strips, 3mm thick, inserted in position, confirm to design, 38mm wide all as specified and directed
M & L glazed ceramic coloured tiles in vertical surface 350x250x7mm ) thick set and jointed in neat cement slurry including 10mm thick for backing coat for tiles in CM 1:4 all as specified and as directed
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises all as specified and directed.
M & L 10mm thick rendering in CM 1:4 using water proofing compound at the rate of 3% weight of cement over concrete surfaces complete all as specified and as directed.
Taking down plastering on brick wall& ceiling etc including racking out joints, hacking for key, scrubbing down with water etc all as specified and directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty in squares n exc 0.5 sqm in each pane all as specified and directed
M & L for preparation of old wooden surface and applying two coats of synthetic enamel paint over 10cm width or girth complete all as specified.
Material & Labour for preparation of new steel surface of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer.
S & F, 15mm dia. steel water tubing 'medium grade' galvanised, with all fittings & fixed complete to walls & ceilings or laid in floors all as specified and directed.
S & F, 20mm dia. steel water tubing 'medium grade' galvanised, with all fittings & fixed complete to walls & ceilings or laid in floors all as specified and directed.
Taking up & down steel tubing & connections, inc. cleaning for refixing or removal to store 15 mm dia all as specified and directed.
Taking up & down steel tubing & connections, inc. cleaning for refixing or removal to store 20 mm dia all as specified and directed.
Disconnecting existing tanks setting aside (or laying if required) for carry out the roof repairs cleaning and removing all scale & dirts etc from tanks & hoisting reconnecting & refixing in position of the tank capacity exc 250 Ltrs & n.exc 500 ltrs complete all as specified and as directed.
Disconnecting existing tanks setting aside (or laying if required) for carry out the roof repairs cleaning and removing all scale & dirts etc from tanks & hoisting reconnecting & refixing in position of the tank capacity exc 500 Ltrs & n.exc 1000 ltrs complete all as specified and as directed.
S&F Gun metal gate valve with iron wheel head screwed both ends for iron pipe 20mm bore all as specified and directed.
S&F 450 mm long PVC connections, hot and cold, 15 mm dia with PTMT nuts, complete all as specified and as directed.
S & F 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints fixed to walls or laid in trenches/floors with necessary fittings such as clamps etc complete all as specified and directed.
All as per item No 45 here-in-before but 75mm bore.
S & F PVC (SWR) bends of 110mm bore dia complete all as specified and directed.
Demolition of brickwork or stone/boulder mansonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles.
Demolition of cement concrete in roof incl existing roof teratement (other than ground floor) and removing debris to a distance of n.exc 100M away from the bldg. all as specified and as directed.
Demolition and breaking up drains pipes (salt glazed ware, AC, PVC or Reinforced concrete etc) of any description and any size.
M & L Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, in floors incl 15mm thick screed bed in CM 1:6 etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all as specified and directed.
M&L for Chequered cement concrete tiles with grey cement and pigments of size 300cmx300cmx20-25mm thick set, jointed and pointed in neat cement slurry over and including 15mm thick CM 1:6 screed bed in flooring complete all as specified & directed.
M&L Rendering 10 mm thick cement plaster in CM 1:3 on concrete surfaces on ceiling incl finishing even & smooth w/o using extra cement all as specified and directed.
M&L Rendering 15 mm thick cement plaster in CM 1:6 on faces of brick works / concrete surfaces on wall incl finishing even & fair w/o using extra cement all as specified and directed.
M&L for 15mm thick rendering on brick wall or concrete surface in cement mortar 1:4, surfaces finished even and smooth without using extra cement complete all as specified and directed.
M&L Preparation of plastered or unplastered old decorated surfaces and applying two coats of oil bound distemper on walls. complete all as specified and directed.
M & L for applying 2 coats of OBD on new surface over one coat of priming paint including wall care putty on walls and complete removal of existing treatment all as specified and directed.
M & L for preparation of new plastered or un pastered surfaces of walls and applying two coats of cement base paint over one coat of primer complete all as specified and directed.
M&L for two coats of cement based paint on old plastered surfaces of walls including preperation
M & L for three coats of white wash including preparation of new plasted ceiling all as specified and directed
Taking down existing water tanks exc 500 & n.exc 1000 ltrs capacity and removing to store and S & F 1000 ltrs capacity rotational moulded polythene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in positiion all as specified in SSR Part-I
S&F in repairs wash down water closet (pedestal pattern) complete white with plastic water closet seat black closed pattern with flat bottom anc cover and mild steel chromium plated or aluminised hinging device and flush pipe of polythelene of low or density or PVC 32mm dia for low level flushing cistern complete all as specified and directed
S & F in repair Wash Basin with Pedestal Complete set incl all fitting & fixtures complete all as specified (Make : Hindware Cat no : 10098)
Supply and fixed in repairs CP WHB mixtuer cast coper alloy with central hole for WHB and long shank fancy type 15 mm bore complete all as directed.(Make-Jaquar Cat. No. Con-167KNB) or its Equivalent.
S & F in repair Wall Mixture cromium plated incl all fitting & fixtures complete all as specified (Make : Hindware Cat no : F320011)
Supply and fixed in repair Concealed stop cock with wall flange including all fittings complete all as specified and directed (Make-Jaquar CON-083KN) .or equivalent.
S&F CP angle cock with wall flange copper alloy, fancy type bore 15mm fixed in repairs. (Make : Jaquar Cat part No FON-40053) complete all as specified and directed.
S&F CP two way bib taps with wall flange dia 15mm, fancy type fixed in repairs. (Make : Jaquar Cat part No LYR-38041) complete all as specified and directed.
S&F CP health faucet fixed in repair (Make : Jaquar Cat part No ALD-565) complete all as specified and directed.
S&F in repair CP overhead shower dia 105 rounded with revolving joints (With Body Rotation) & 115 mm long arm shower with rabit cleaing system and all Complete all as directed.Make : Jaquar Cat No OHS 1709 or equivalent.
S&F CP toilet roll holder with flap fancy type (Make : Jaquar Cat part No CAN - 1153N) complete all as specified and directed.
S&F soap dispenser with metallic bottle long fancy type chromium plated (Make : Jaquar Cat part No CAN-1137N) complete all as specifed and directed.
S&F corner glass shelf (with bracket) fancy type chromium plated (Make : Jaquar Cat part No CAN-1173) complete all as specified and directed
S&F CP towel ring round with flange (Make : Jaquar Cat part No CAN-1121N) complete all as specified and directed
M&L priming the plastered roof surfaces with bitumenous primer @ 0.30 Kg per sqm, apply hot bitumen VG - 30 @ 1.20 Kg/Sqm and applying APP based polymeric membrane minimum weighing 3.5 Kg per Sqm and minimum 3mm thick reinforced with polyster non wove fabric (Wt not less than 150 gms/per Sqm) and on primed surface by forced application and apply bitumen base Aluminium paint @ 0.20 Kg/ Sqm complete all as specified.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified & directed by Engg in Charge.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as per existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
M & L for Point wiring in Concealed conduit in wall with 1.5 Sq mm copper conductor single core PVC insulated cable FRLS type 1100 V grade multistranded drawn through conduit and including rigid PVC conduit and conduit accessories of suitable dia medium grade and pressed steel terminal boxes of 1.6 mm thick MS, duly painted with red oxide metal primer including fixing/grouting sunken/ surface as per site requirement covered with 3 mm thick laminated sheet including running up of 1.5 Sq mm copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc all as specified for: (a) One light point controlled by one, one way switch 5A, SP
(b) One ceiling / exhaust fan point controlled by one, one way switch
(c) One 2/3 pin 5 Amps socket outlet point controlled by one switch on the same board
(d) One 3 Pin 5 Amps switch socket Independt board
(e) One bell point controlled by one bell push
Description all as per item No 79 here-in-before but using 4 Sq mm single core copper conductor cable multistranded PVC insulated FRLS 1100 Volts grade for 6/16 Amps switch socket combination point including running of 4.00 Sq mm copper conductor PVC wire as earth continuity conductor along with wiring and connecting to the common earth dolly.
S & F Switch piano type single pole one way flush type 5 Amps capacity 230 volts.
Supply and fix switch socket combination flush type multipurpose 2/3 pin 5 Amps, 230 Volts complete all as specified.
Supply and fix socket outlet flush type multipurpose 2/3 pin 5 amps, 230 volts all as specified
Supply and fix switch socket combination flush type multipurpose 5 in 1, 5/16 Amps, 230 Volts complete all as specified.
S&F bell ding dong working on 230 volts AC supply
S&F Ceiling fan regulator step type AC 240 volts suitable for 1200/1400 mm sweep
S&F Bell push one way flush type 5 Amps capacity 230 volts
S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 Volts of size 65 x 50 mm complete all as specified.
S&F angle/lamp holder insulated body surface bakelite including LED lamp of 7 watt with back plate suitable for angle/batten fittings fixed with PVC round blocks all specified
S&F wall mounted box type fitting suitable for LED of 18/22 watt extruded aluminium heat sink provided for efficent heat dissipation including LED lamp complete all as specified and directed by Engr-in-Charge.
Supply and fix 9/10 W LED batten along with integrated driver complete all as specified and directed by Engr-in-Charge.
S&F Security Lights of 1x15 watt LED light with high power LED and unique peanut lens to ensure uniform distribution and including provision of 1.5 sqmm 3 core multistranded copper conductor cable from light fitting to junction box complete all as specified and directed by Engg-in-Charge
M&L bracket made out of GI pipe of suitable dia for Sr No 96, not less than 1.2 mtr long and fixed on walls with 2 nos MS clamps made out of MS flat of suitable size thickness complete with MS nuts, bolts and washers etc bent to required shape complete all as specified and directed by Engg-in-Charge.
S&F Metal Clad socket 3 pin 20 Amps industrial type with plug top and MCB SP 32 Amps all enclosed in sheet metal enclosure.
S & F Vertical type TPN DB 4 way double door with 200 Amps rated bus bar 415 volts AC 3 phase 50 Hz suitable for and including 100 Amps TPN 25 KA as incomer and 12 outgoing SP MCB's with fixed magnetic setting with locking arrangement complete all as specified and directed
S & F Sheet metal enclusure MCB DB SPN 8 way double door with 200A rated bus bar 240V double door with flush type locking system complete all as specified
S & F MCB SP 6 to 32 Amps 240 volts for fixing in MCB DB's all as specified.
S & F MCB SPN 40 Amps 240 volts for fixing in MCB DB's all as specified
M & L for Submain wiring with two single core 6 Sq mm PVC insulated cable FRLS type copper conductor multistranded 1100 Volts grade drawn through and including rigid PVC conduit and conduit accessories of 25 mm dia medium grade including running up two one of 6 Sq mm copper conductor multistranded PVC insulated FRLS cable as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing unserviceable sub main wiring and making good the disturbed surface to match with the existing all as specified. Note:-two runs of cable, one run of earth contuinity conductor and one run of conduit shall be measured and paid as one unit length.
Earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground to a depth not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 m below normal ground level connected to GI earth lead wire 4 mm dia by means of bolts, nut, check nuts and washers etc of galvanised iron and earth lead protected by provision of GI pipe 15 mm bore of medium grade from earth electrode to DBs/Main switch all as shown in Electrical Plate No 3 of SSR Part I and connected to main switch board including excavation and earth work in any type of soil, PCC chamber in 1:2:4 Type B-1 using 20 mm graded stone aggregate 75 mm thick RCC cover in 1:2:4 type B-1 reinforced with 6mm dia bars at 75mm c/c both ways with 12mm dia MS bar handle made to shape, 20 mm dia medium grade GI watering pipe perforated at bottom of required length with funnel and wire mesh, common salt and charcoal filling complete including testing on completion all as specified (Note: GI pipe 15mm dia & GI earth lead 4mm dia upto 7.5 m length is deemed to be included in quoted rate)
Disconnecting and removing ceiling fan of 1200/1400 mm sweep from any height bringing down, dismantling, cleaning internally and externally, thoroughly examine, replacement of split pins, cotter pins and check nuts etc overhauling, lubricating with approved lubricants, reassembling, including replacement of wornout/defective parts, refixing in original position including minor repairs for the smooth functioning and provision of new flexible wire of size 23/0.0076 multistranded copper conductor cable from ceiling rose to fan
M & L Rewinding of burnt ceiling fan motor of 1200 / 1400mm sweep with supper enameled copper wire of suitable size of any make, type, model incl transportation (inclusive of material & labour) complete all as specified and directed by Engineer -in-charge.
Supply only Capacitor 2.5 Mfd capacity 240 Volts.
Supply only Sealed ball bearing
Supply only Rubber bushes
M&L spray painting of fan of any size with two coat of synthetic enamelled copper wire os suitable size for 1200 to 1400 mm sweep of any make ,type,model including necessary transportation complete all as specified and as directed.
S&F exhaust fan metal body with louvers of 300mm sweep and connectiong up with PVC insulated copper conductor multistranded cable of suitable size and specification as provided by the manufacturer/company from ceiling rose to connector complete all as specified and as directed by Engr-in-Charge
Cutting of wall in square shape and making opening suitable for mouting of 300 mm dia exhaust fan and making good distrurbed surface matching with existing colour and all including grouting of nuts and bolts all as specified and directed
KOGANTI CONSTRUCTION COMPANY
BEEGEE DESIGN SYSTEMS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .