Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.3 Cr+₹28.9 L (28.1%)Admitted-Finance | ₹1.3 Cr+₹28.9 L (28.1%) | L2 | Admitted-Finance |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| Sl No | Description | Qty | Unit | M S Electricals L2 | Shiva Electricals Company L1 |
|---|---|---|---|---|---|
| 1.00fctusl Iyku 2025&26 ds vUrZxr fo|qr uxjh; forj.k e.My & f}rh;] uks,Mk ds {ks= 11@0-4 dsoh midsUnzksa dh {kerko`f) en esa 50 ua0 vfrHkkfjr ifjorZdksa dh {kerko`f) djus ls lEcfU/kr dk;ZA | |||||
| 2.00Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 21 | |||||
| 3.00 | PCC Pole 11 Mtr Long | 1 | Nos. | 1,500 ₹6,000 | 650 ₹2,600 Lowest |
| 4.00 | PCC Pole 8.5 Mtr Long | 1 | Nos. | 650 ₹3,900 Lowest | 650 ₹3,900 Lowest |
| 5.00 | Stone Pad | 1 | Nos. | 10 ₹100 Lowest | 100 ₹1,000 |
| 6.00 | ACSR Weasel Conductor | 1 | Mtr. | 4 ₹360 Lowest | 10 ₹900 |
| 7.00 | Dropper Channel | 1 | Nos. | 100 ₹400 | 20 ₹80 Lowest |
| 8.00 | T Channel 125x65x1300 mm | 1 | Nos. | 100 ₹600 | 20 ₹120 Lowest |
| 9.00 | Top Channel | 1 | Nos. | 100 ₹100 | 20 ₹20 Lowest |
| 10.00 | Pin Insulator | 1 | Nos. | 50 ₹2,750 | 5 ₹275 Lowest |
Tender Value
Refer Docs
EMD Value
₹1.4 L
Closing Date
25 Sept 2025, 12:00 pmClosed
Superintending Engineer
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
Work related to increasing the capacity of 50 Nos. overloaded transformers under the capacity enhancement item of area 11 0.4 kV substations of Electricity Urban Distribution Division - II, Noida under Business Plan 2025-26.
2025_PVVNL_1072473_1
E-Tender No. 32/2025-26, EUDC-II, Noida
Open Tender
Electrical Works
Item Rate
30 days
Office of the S.E., EUDC-II, Sec-18 (Ansal) Noida
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
S.E., EUDC-II, Noida.
₹1.4 L
6 Oct 2025
8 Sept 2025
25 Sept 2025
8 Sept 2025
25 Sept 2025
8 Sept 2025
Amount
fctusl Iyku 2025&26 ds vUrZxr fo|qr uxjh; forj.k e.My & f}rh;] uks,Mk ds {ks= 11@0-4 dsoh midsUnzksa dh {kerko`f) en esa 50 ua0 vfrHkkfjr ifjorZdksa dh {kerko`f) djus ls lEcfU/kr dk;ZA
Safe Cartage of following centralised stock material from any of the Store Center of PVVNL Discom to work site including Loading from Store and safe unloading at site for Item No. 3 to 21
PCC Pole 11 Mtr Long
PCC Pole 8.5 Mtr Long
Stone Pad
ACSR Weasel Conductor
Dropper Channel
T Channel 125x65x1300 mm
Top Channel
Pin Insulator
EARTHING
Disc Insulator
STAY SET
Connecting Lead 1x16 Sq mm
11 KV Fuse Set
11 KV Disc Fitting
LT PVC Cable Al 1x240 Sq mm
LT ABC (3x120+1x95+1x16) Sq mm
LT XPLE CABLE ALU. 3.5X400SQMM
Distribution Box with clamp
250 KVA T/F
Errection of above Centralised material and Supply and errection of the below De-Centralised material for completing the works as per RESPO.
Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connections with complete work in all respects.
The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, 'E' bracket 75x10mm, and other accessories as per RESPO. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule. Double Pole Structures (a) PCC/ST - 11 Mtr. Long Pole and 8.5 Mtr Lon
Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming. Road Restoration charges shall be inclusive in quoted rates. Single Pole and Double Pole (a) 11M Long ST/PCC Pole
Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement.
Laying Fixing of LT XLPE Alu. Cable 3.5x400 sqmm at different locations of T/F as per site requirement. as per site requirement.
Installation and Fixing of 11 KV Fuse Set: Assembling and installation of fuse set on the fuse set structure of the T/F. The work includes fabrication for proper fixing, if required. Complete work in all respect.
Laying, spreading, lifting and final sagging of 3 OR 4 phases ACSR Weasel conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement.
Fixing of Stone Pad as per site requirement with complete work in all respect as per RESPO.
Fixing of Dropper channel as per site requirement with complete work in all respect as per RESPO.
Fixing of T channel as per site requirement with complete work in all respect as per RESPO.
Fixing, tightening & nozzling of stay wire with stay rod with the poles including providing & fixing of Stay Insulators of 11KV and Stay Clamps AND Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc.
Fixing of Top channel as per site requirement with complete work in all respect as per RESPO.
Fixing of 11KV Disc Insulator with Fitting as per site requirement with complete work in all respect as per RESPO.
Fixing of 11KV Pin Insulator with Pin as per site requirement with complete work in all respect as per RESPO.
Driving of MS earth rod of size 20x2500 mm in earth and jointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballast in ration 1:4:8 in Block 600*600*300 mm with binding & nuzzling including providing & fixing of stay insulator complete in all respect with grouting
Fixing of Lead 1x16 Sq mm at Distribution T/F with complete work in all respect.
Fixing of LT PVC Cable Al 1x240 Sq mm at Distribution T/F with complete work in all respect.
Fixing of LT XPLE CABLE ALU. 3.5X400SQMM at Distribution T/F with complete work in all respect.
Fixing of Distribution Box with clamp at Pole or site requirement with complete work in all respect.
Chemical Earthing of T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mm terminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.
Construction of New Plinth for 250KVA & above capacity Distribution Transformers, The size of plinth shall be 2M long 2m wide and the height of the plinth shall be 1.50 M with 20 cm. thick top slab with 02 no. 125x65mm MS channel 2 M long embedded in it. The repairing work includes excavation of earth, laying of brick ballast pad for foundation brickwork, CC and plastering and proper curing. The ratio of cement/course sand/fine sand/brick ballast/stone grit as per RESPO schedule including unloading and Loading of the transformer with complete work in all respect. (All work and material in the scope of the Contractor)
Construction of New Fencing of Transformer. The fencing shall be frame of size 1.5mt x1.80 mt fabricated out of MS angle iron of size 40x40x5 mm having 2 Nos. legs of 45 Cm. long in each frameduly welded and fixed with wire mesh of size 75mm 25mm, 10 SWG within the frame, pressed under MS flat of size 25x5 mm inside the angle iron on all four sides with the help of approx. 20 Nos. bolts and nuts. of 10 mm dia along with cross bracing of 25x5 mm MS flat on every frame will be grouted in 1:2:4 cement mortar with cement, coarse sand 20 mm gauge stone ballast in the size 0.22x0.22x0.45 Mtrs. Every frame after repairing will be painted with one coat of red oxide and two coats of blue synthetic enamel paint of approved make after proper cleaning. The above mentioned frame will be jointed with each other with 70 mm long MS flat of size 25x5mm by first class welding as per site. Fabrication and providing of wire mesh fencing frame for gate of size 1.5x180 Mtrs. Fabricated as items no. 2 and fixing of gate frame at each S/S as per site requirement with grouted frame providing 3 Nos. 100 mm size heavy duty hinges duly welded and having suitable locking arrangment and proper painting.
Supply and Installation and Commissioning of Horizontal 11KV TPMO for Distribution T/F with complete work in all respect..
Supply of Red Oxide Paint best quality for painting of structure and paint the structure as per site requirement.
Supply of Alu. Paint best quality for painting of structure and paint the structure as per site requirement.
Supply and Fixing of Clamps for LT T off with Bolts & Nut as per site requirement.
Supply and Fixing of Holding Clamps as per site requirement.
Supply and Fixing of Suspention Clamp with 1 Hook as per site requirement.
Supply and Fixing of Dead & Clamp with 1 Hook as per site requirement.
Supply and Fixing of Peircing Clamp as per site requirement.
Supply and Fixing of All. Lug 400 Sq mm as per site requirement.
Supply and Fixing of All. Lug 120 Sq mm as per site requirement.
Supply and Fixing of All. Lug 35 Sq mm as per site requirement.
Supply and Fixing of LT Incomming Pannel with metering as per site requirement.
Supply and Fixing of Cooper L-Piece 62x225x12 mm as per site requirement.
Supply and Fixing of Cooper L-Piece 50X225X10MMmm as per site requirement.
Supply and Fixing of Al. Leg Long Barrel off size (LS) as per site requirement.
Supply and Fixing of 4 Core LT MCB with Box (LS) as per site requirement.
Supply and Fixing of Danger Board with clamps as per site requirement.
Dismentaling of old and used 49 Nos. 100KVA T/F and 1 Nos. 160KVA T/F from the different sites under EDD-Dadri, Greater Noida and Jewar and its Safe Carriage to any Store Centre of PVVNL including loading and unloading from both sides.
M S Electricals (BID ID -5551201)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .