GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
SPECIAL REPAIRS REPLACEMENT OF OF LT PANELS OF VARIOUS SIZES CAPACITIES AND CONNECTED WORKS AT SW ZONE
2026_MES_786788_1
9050/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RANGAPAHAR
Class D Category b(i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹90,000
28 Aug 2026
28 Aug 2026
19 Sept 2026
28 Aug 2026
17 Sept 2026
11 Sept 2026
28 Aug 2026 - 3 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation, erecting, commissioning and testing new factory made LT panel board cubical out door type in repairs/replacement of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following complete all as specified and as directed. | 1 | Each Job | - | - |
| 1.01 | Item 01 Contdd...
INCOMING MCCB
(a) 400 Amp 4 pole, 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu- 01 Nos.
OUTGOING MCCB
(a) 100 Amp 4 pole MCCB 36 KA breaking capacity ,microprocesser LCI type, Ics is 100% of Icu - 03 Nos.
(b) 160 Amp 4 pole MCCB 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 02 Nos.
(c) Spare space for MCCB - 01 No
(d) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
(e) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set.
(f) LED Indicating lamps RYB set of three -01 Sets
Note :
(a) Cable Entery should be Incoming/outgoing from seperate cable galley.
(b) All Incoming/Outgoing MCCBs provide suitable size of copper connection plates.
(c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each.
(d) Provision of gland hole, brass glands as per direction of Engr-in-Charge.
(e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc
(f) Main busbar/link bus bar should be full covered back size also. | - | - | - | - |
| 2 | Supply, installation, erecting, commissioning and testing new factory made LT panel board cubical out door type in repairs/replacement of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following complete all as specified and as directed. | 2 | Each Job | - | - |
| 2.01 | Item 02 Contdd...
INCOMING MCCB
(a) 250 Amp 4 pole, 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 01 Nos.
OUTGOING MCCB
(a) 100 Amp 4 pole MCCB 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 02 Nos.
(b) 125 Amp 4 pole MCCB 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 01 Nos.
(c) 63 Amp 4 pole MCCB 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 02 Nos.
(d) Spare space for MCCB - 01 No
(e) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
(f) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set.
(g) LED Indicating lamps RYB set of three -01 Sets
Note :
(a) Cable Entery should be Incoming/outgoing from seperate cable galley.
(b) All Incoming/Outgoing MCCBs provide suitable size of copper connection plates.
(c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each.
(d) Provision of gland hole, brass glands as per direction of Engr-in-Charge.
(e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc
(f) Main busbar/link bus bar should be full covered back size also. | - | - | - | - |
| 3 | Supply, installation, erecting, commissioning and testing new factory made LT panel board cubical out door type in repairs/replacement of suitable size for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 45 cm height for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating not less than 1.5 times the rated capacity of the incomer MCCB. The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators. All interconnections between the main bus bar as well as outgoing feeders shall be carried out with TPN Aluminium bus bar of rating not less than 1.5 times rated capacity of of individual outgoing feeders. All control wiring shall be with FRLS PVC insulated 6 sqmm multi-stranded copper conductor and shall be properly bunched. The panel board shall have bottom channel of size 75 x 40 mm and complete mounted or fixed on PCC foundation above 0.45 mtr on floor and cable connection with suitable size of copper lugs and suitable size chrome plated glands provided for incoming and out-going cables comprising the following complete all as specified and as directed. | 6 | Each Job | - | - |
| 3.01 | Item 03 Contdd...
INCOMING MCCB
(a) 200 Amp 4 pole, 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 01 Nos.
OUTGOING MCCB
(a) 100 Amp 4 pole MCCB 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 02 Nos.
(b) 63 Amp 4 pole MCCB 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu- 03 Nos.
(c) Spare space for MCCB - 01 No
(d) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
(e) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set.
(f) LED Indicating lamps RYB set of three -01 Sets
Note :
(a) Cable Entery should be Incoming/outgoing from seperate cable galley.
(b) All Incoming/Outgoing MCCBs provide suitable size of copper connection plates.
(c) All Incoming/Out going MCCBs provide spreader Links - 04 Nos Each.
(d) Provision of gland hole, brass glands as per direction of Engr-in-Charge.
(e) All Incoming/out goings MCCBs should be Marking label/End plate/End clams/suitable size of Terminal Block Stud/screwless type etc
(f) Main busbar/link bus bar should be full covered back size also. | - | - | - | - |
| 4 | Supply, installation, erecting, commissioning and testing new factory made Bus Bar panel board cubical out door type in repairs/replacement of size 1200 MM X 600 MM X 500 MM for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 60 cm legs & bottom channel of size 75 x 40 mm for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating 250A, 4Pole The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators comprising the following complete all as specified and as directed.
INCOMING MCCB
(a) 250 Amp 4 pole, 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu - 01 Nos.
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set.
c) LED Indicating lamps RYB set of three -01 Sets
Note : Bus bar should be fixed on PCC and its rate included in quoted rate. | 2 | Each Job | - | - |
| 5 | Supply, installation, erecting, commissioning and testing new factory made Bus Bar panel board cubical out door type in repairs/replacement of size 1200 MM X 600 MM X 500 MM for housing of all equipments & proper heat dissipation, CPRI approved weather/dust proof, made out of 3.15 mm thick CRCA sheet powder coated with front and back side openable with suitable cable chamber and front side shutters with locking arrangement panel base of angle iron 50x50x6 mm upto 60 cm legs & bottom channel of size 75 x 40 mm for 433 volts, 3 phase, 4 wire system including TPN Aluminium bus bar of rating 200A, 4Pole The TPN bus bar shall be insulated with colour coded heat shrinkable sleeves and shall be mounted on F class insulators comprising the following complete all as specified and as directed.
INCOMING MCCB
(a) 200 Amp 4 pole, 36 KA breaking capacity, microprocesser LCI type, Ics is 100% of Icu- 01 Nos.
Metering: a) AC digital voltmeter 0-500 volts Size 4"X4" with 3 Ph selector switch-01 Nos
b) 0-500 digital Amp meter with suitable Size 4"X4" with 3 Ph selector switch- 01 Set.
c) LED Indicating lamps RYB set of three -01 Sets
Note : Bus bar should be fixed on PCC and its rate included in quoted rate. | 2 | Each Job | - | - |
| 6 | M & L for Earthing complete with GI earth plate 60cm x 60cm x 3mm thick electrode, burried directly in ground (earth pit not less than 2.70 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper strip 32X6mm size up to test point by means of nuts, bolts, check nuts and washers of copper including excavation and earth work, PCC (1:3:6) type C-1 pit, medium grade pipe for watering arrangement and 15mm bore dia GI pipe, medium grade GI pipe of 40 mm dia for protection of earth lead, 50mm thick RCC (1:2:4) type B-1 cover reinforced with 8mm dia TMT bars @ 15cm C/C both ways and with handle made out of 10mm dia bars, funnel, wire mesh etc. as shown in electrical Plate No. 03 of SSR Part-I connected to earthing test point including taking down old unserviceable material and testing on completion complete all as specified and as directed. | 18 | Set | - | - |
| 7 | S&F in repairs/replacement Weather Proof thermo plastic (Polysterene) Cable Junction box , having protection class IP-54 and of overall size min (450 x 375 x 200) mm duly fixed with the pole/wall with terminal (25x3mm) clamp, GI bolts, nuts, washers and 2 Nos polymade weather proof cable glands of suitable size cable (Complete with check nut) and including 04 Nos Aluminium bus bar with colour coded heat shrinkable sleeves and shall be mounted on F class insulators of capacity 200 amps complete all as specifed and as directed . | 22 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.53 MB
Tender9050.pdf
Tender Documents • 1.47 MB
BOQ_881717.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .