Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.4 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹40.2 L+₹1.4 L (3.70%)Rejected-Finance 21 9TH MAIN 4TH CROSS GOWDAKEHOLA BAGALAKUNTE NAGASANDRA POST BANGALORE 560073 | BENGALURU URBAN | KARNATAKA | 560073 | L2 | Rejected-Finance Rejected | |
| 3 | L3₹40.6 L+₹1.8 L (4.63%)Rejected-Finance | L3 | Rejected-Finance Rejected | |
| 4 | L4₹40.8 L+₹2.1 L (5.33%)Rejected-Finance NO 64 5TH C MAIN 7TH CROSS AGROGYAPPA LAYOUT KAMMANAHALLI NEAR RAJ KUMAR PARK BANGALORE 560084 | BENGALURU URBAN | KARNATAKA | 560084 | L4 | Rejected-Finance Rejected | |
| 5 | L5₹41.3 L+₹2.5 L (6.47%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | L5 | Rejected-Finance Rejected |
Tender Value
Refer Docs
EMD Value
₹70,000
Closing Date
24 Jan 2022, 6:00 pmClosed
PRTC BANGALORE
GARRISON ENGINEER NORTH BANGALORE T 64 MEANEE LINES MEG AND CENTRE BANGALORE 560042
CLEANING AND REMOVAL OF VEGETATIONS FROM ROOFS CHAJJA OVER HEAD SERVICE TANKS AND OTHER MISC WORK UNDER BUILDINGS IN MD ACCN OF ZONE A1 REPAIRS TO BRICK WORK PLASTERING FLOORING ROOFS AND OTHER MISC WORKS IN OTM ACCN OF PRTC AND OTHER AREAS IN THE
2022_MES_499238_1
8274
Open Tender
Civil Works
Item Rate
150 days
PRTC BANGALORE
Class D Category a(i)
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER NORTH BANGALORE
₹70,000
Yes
31 Jan 2022
4 Jan 2022
26 Jan 2022
4 Jan 2022
24 Jan 2022
11 Jan 2022
4 Jan 2022 - 10 Jan 2022
Amount
Taking down chowkat or frames with shutters (without taking of shutter from the frame) area not exc 1.5 sqm each all as specified and as directed.
All as per Sl Item No. 1.001 above but area exc. 1.5 sqm and n exc 4 sqm each.
Taking down shutters of any descriptionarea n.exc. 1 Sqm each all as specified and as directed.
Taking down shutters of any description area exc. 1 sqm but not exc. 2 Sqm each all as specified and as directed.
Second class hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid rounded or chamfered, put together with glue pinned at joints complete all as specified and as directed.
Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube fixed in opening as per specification & drawing all as specified and as directed.
Factory made solid PVC moulded door shutters, 28 to 30mm thick (stiles) with 2, 4 or 6 raised panel design with 2mm thick moulded PVC sheet on the front face & 2mm plain colour PVC sheet on back face supplying and fixing in frame at site as per specification & drawing all as specified and as directed.
Second class hardwood 35mm thick plain framed, panelled shutters (two panel) of with lock rail and panel of 9mm BWP commercial ply or 12mm venereed particle board with commercial veneering on both faces. rail and style all as per IS:1003 (Part-I), kiln seasoned and chemically pressure treateds fixed to chowkhat all as specified and as directed.
Flush door shutters 35mm thick, factory made as per IS:2202 (Part-I 1999) solid core construction, with block board core and plywood face panels, commercial type on both sides including providing teak wood beading as per drawing and painted to match the door fixed to chowkhats all as speified and directed.
Second class hard wood 35mm thick glazed and skeleton shutters open rabated and prepared to receive glass gauge etc (without sash bars), edges of framing plain chamfered or rounded, fitted with cut and mitred beads for securing glass, etc, size of shutters as specified in SSR Pt-I, Section 8, clause 8.24(a); made out of for door shutter fitted to chowkhats all as specified and as directed.
Steel windows of box type frame (80x60x1.25mm profile sheet for frame) with box type shutter inside glazed shutters and out side gauged shutter with steel handle, telephonic peg stay complete with glazing bars and 08 Nos of 10 x 10 mm square guard bars in equal spacing, devotailed or welded as per TD drg no 539 sheet 1/3 to 3/3 including one coat of red oxide primer all as specified and directed. NOTE :- PCC in frame, glass pane & wire mesh shall be meausured and paid separately under relevant items.
Steel ventilators top hung with double shutter including peg stay complete with glazing bars all as specified and as directed.
Mild Steel work as in bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 complete all as directed.
Rolled Mild steel framed work as in doors or gates of angle or other sections with gusset plates, rails braces, etc complete drilled for fixing of steel sheeting or other covering, doors etc, to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings(exclusive of steel sheeting or other covering, running rails and guides) and hanging ; also fastening and fixing complete including painted with one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop/factory before fabrication complete all as specied and directed
Plain Cement Concrete, (1:2:4), type B0, using 12.5mm graded stone aggregate as incopings, hold fast, in steel frame of window back filling and in roof kerbs of mud stops, rounded or chamfered on edges cills, steps etc; all as specified and directed.
Butt hinges medium weight, cold rolled mild steel 100mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed
Butt hinges medium weight, cold rolled mild steel 75mm long and fixed to door frame and shutter duly welded/screwed complete all as specified and as directed
Aluminium anodised barrel tower bolt of extruded section of size 200mm long complete all as specified and as directed.
Aluminium anodized barrel tower bolt of extruded section of size 150mm long complete all as specified and as directed.
Aluminium anodized barrel tower bolt of extruded section of size 100mm long complete all as specified and directed.
Aluminium alloy anodised, length of bolt 300 mm sliding door bolt with hasp, staple(bolt type) and fixing clips of sheets, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium and fixed all as specified and directed.
Extruded Aluminum handles 150mm size, fabricated type, anodised all as specified and as directed.
Extruded Aluminum handles 100mm size, fabricated type, anodised all as specified
Mortice lock with four lever brass body,100mm size suitable for 25 to 60mm thick doors including screwing and fixed in repairs all as specified and as directed.
150 mm floor door stopper of aluminium alloy powder coated, with hard down steel spring all as specified and as directed.
Magnet door catcher made of stainless steel complete all as specified and directed.
Rubber door buffer 125mm size fixed with brass screws complete all as specified and directed.
Eye viewer (Magic eye) suitable fro doors made of stainless steel complete all as specified and directed.
Mild steel sliding door bolts 300mm long, plate type, stove enamelled black, with bright bolt not less than 12mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed to steel door complete all as specified and directed.
MS pressed handles oval type stove enameled black 150mm size complete all as specified and as directed
Door closer hydraulically regulated designation No.3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg of aluminium (Die cast body) fixed in repairs complete all as specified and as directed.
Mild steel 300mm long, ordinary rat tail rod pattern springs, including roller and roller plate complete all as specified and directed.
PTMT butt hinges, 100 mm long and fixed with steel screws complete all as specified and as directed.
PTMT tower bolts, 150 mm long and fixed with steel screws complete all as specified and as directed.
PTMT door handle, 150 mm long and fixed with steel screws complete all as specified and as directed.
Galvanised mild steel wire cloth 0.56mm nominal dia and average width of aperture 1.18mm and fixed with tinned tack or galvanised wire staples including necessary putty or beading all as specified and as directed.
All as per Sl Item No 1.036 above but fixed in repairs.
Hacking out old broken glass (any thickness, size, quality or description) from wooden surface concrete or brick surrounds. Glazed with putty or fixed with beads all as specified and as directed.
4 mm thick sheet glass, ordinary quality and glazing with oil putty and glazing clips in metal frame and second class hard wood beading in wooden frames in squares not exceeding 0.5 Sqm in each pane all as specified and as directed.
Figured glass, pin head type 4mm thick ordinary quality and glazing with oil putty/beading in square not exceeding 0.5 Sqm in each pane all as specified and as directed.
19 mm thick ( 7 Nos of ply) plywood grade BWP, type BB and decorative laminate type 1 of surface finish having 0.9 mm thick, colour and pattern as approved, fixed with approved adhesive as per manufactures instructions fixed with screws to timber frame work, alround 6mm thick teak fillets fixed in kitchen Cabinet or cupboards all as specified and as directed.
100 mm size hasp and staple, safety type, aluminium anodized with mild steel hinge pin including bolt to hinge plate and fixed with screws /fixed in repairs all as specified and as directed.
Continuous (piano) hinges, 30mm width of flaps (when open) , mild steel bright finish or electroganised fixed to wooden or angle iron frame complete all as specified and as directed.
40 mm dia, cupboard knobs of Aluminum anodised with nut, screw and washer, polished /fixed in repairs all as specified and as directed.
Drapery rods, 25 mm dia, having corrugated PVC extrusion on electric resistance welded MS pipe with fancy type 02 nos knob and 02 nos brackets for each door/windows etc complete all as specified directed Make : soffio II of Vista all as specified and as directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coveringscomplete all as specified and directed.
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Rolled Mild steel work as in joist, channel, angle, or tee sections, as in purlins fixed independently, without connecting plates, etc. of grade Fe 410-W complete all as specified and as directed.
Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick (colour on +)of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixd with self tapping screws all as specified and as directed.
All as per Sl item No. 1.049 above but plain sheet for ridge.
Powder coated anodised aluminium frame for doors, windows ventilators with one or more rebates including jointing cleat for fixing etc.complete all as specified and directed.
Powder coated anodised aluminium door shutters, aluminium section weighing 0.55kg/m including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, anodised alumnium snap beading, screws etc. complete all as specified and directed.
Powder coated anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.) hinge type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified and directed.
Aluminium Deco grill of (Indal/ Hindalco) including necessary 'U' clips and necessary fixing arrangements all as specified and as directed.
4.8mm thick Sheet glass, ordinary quality and glazing with oil putty in square exc. 0.5 sq.m in each pane not exc. 0.50 sqm in each pane complete all as specified and directed.
Demolition of brick work or stone/boulder masonry/precast concrete articles and precast concrete block walling built in cement mortar, incl all quoins, arches, pillars complete all as specified and directed.
Pre-cast cement concrete block masonry, type C1 1:3:6(using 20mm graded aggregate) in CM 1:6 with solid blocks,exc 10cm in width and setting in mortar, complete all as specified and directed.
Precast cement concrete 1:3:6, type C1(using 20mm graded stone aggregate) as solid building blocks or slabs 10cm thick (with plain or interlocking joints as directed) setting in cement mortar 1:4 complete in walls complete all as specified and directed.
Dismantling of ceiling boards any description fixed in any thickness and in any position with screws/nails including cover fillets/battens all as specified and as dircted.
E grid suspended false ceiling grid system of size 600x600 mm with main runner 32x24x6 mm , cross Tee 25x24x6 mm and wall angle 22.2x22.2x6 mm .ceiling suspended with 3 mm dia GI wire hanger fixed with steel fasteners, butterfly clips, hold down clips etc incl 6 mm thick HPSC self textured design preprimered non asbestos fibre cement building board fixed to false ceiling complete all as specified and directed.
Taking down cement plaster on brick or stone wall etc any description including taking out joints hacking for key scrubbing down with water etc complete all as specified and directed.
Forming jambs etc to openings (to forgoing item) including cutting toothing and properly bonding in to old work also facing jointing and pointing to match the existing work in Cement mortar (1:4) complete all as specified and directed.
15mm thick rendering in CM 1:6 on brick or concrete surface finishing the plastered surfaces even and smooth with out using extra cement complete all as specified and directed.
Rendering 15mm thick in CM(1:4) mixed with water proofing compound as per manufacturers instructions finishing the surfaces even and smooth without using extra cement including necessary scaffolding complete all as specified and directed. NOTE:- WPC will be measured and paid separately under relevant items.
Extra over rendering or plastering for work in isolated widths or in widths not forming part of general plastering such as in bands, sunk panels, cornices, skirtings, drip moulds and similar work n exc 15 cm in width or girth; including cutting to edges, all mitres and stopped ends
Preparation of new plastered wall surfaces and applying two coat of oil bound distemper over a coat of alkali resistent primer complete all as specified and directed
Preparation of newly plastered wall surfaces and applying three coats of white wash complete all as specified and directed.
Preparation of newly plastered surface of wall and applying two coats of cement base paint over one coat of alkali resistant primer complete all as specified and as directed.
Preparation of new or previously untreated steel and iron surfaces of any description not other wise described over 10cm width or girth and applying two coats of synthetic enamel paint, complete all as specified and directed.
Dismantling of floor, hearth or wall tiling incl cement mortar bedding (but not backing) and removing rubbish off from premises complete all as specified and as directed.
Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl Screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes all as specified and as directed.
Non Skid ceramic tiles 7 to 8 mm thick (square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl screed bed or bedding layer of mortar 15 mm thick in CM 1:4 for laying floor finishes all as specified and as directed.
Glazed ceramic tiles in vertical surfaces 350 x 250x 7 mm/ 450 x 350 x 7 mm/ 300x450x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface over and including 10mm thick backing coat CM (1:3) on brick work or concrete surfaces to receive wall tiles all as specified and as directed.
Taking up or down 15 mm dia existing steel tubing and connections all as specified and as directed.
Taking up or down 20 mm dia existing steel tubing and connections all as specified and as directed.
20 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials complete all as specified.
25 mm outer dia CPVC pipes SDR 11 ( Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors including all fittings and specials complete all as specified.
Vitreous china white wash down water closet (pedestal pattern) including PVC seat cover and connection to drain or out going pipe and to flushing pipe anti-syphonage pipe etc, fixed as in repairs, complete all as specified and as directed.
Vitreous china squatting pan orissa pattern of size 580x440mm white with integral foot rest including P or S trap and for necessary fixing including making good to floor complete all as specified and as directed.
PVC valveless, syphonic action type, flushing cistern, 10ltr capacity,low level, white, with inlet, ball valve, float and handle including brackets, connections to pipes and fixing of chain and pull, or lever, fixed in repairs complete all as specified and directed.
Vitreous china wash basin white flat back size 630 X 450 mm excluding taps,chain and plug and porcelain stopper but incl CI bracket. etc complete fixed in repairs all as specified and as directed.
PVC connections 15mm dia size with PTMT nuts of length 450mm all as specified and as directed.
Grating doom 100mm dia of PTMT (Minimum weight 25gms) complete all as specified and as directed.
15mm bore Bib taps, cast copper chromium plated alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed in repairs complete all as specified and as directed.
Two way bib cock with angle valve combination brass chromium plated, fixed in repairs complete all as specified and as directed.
Chromium plated long body bib tap 15mm dia with CP flange all as per Prayag Cat No 7808 URBONA series or techno commercially equivalent makes specified in PS fixed in repairs all as specified and as directed.
Pillar taps, fancy type, 15mm dia cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly nuts, screwed for iron pipe and fixed in repairs complete all as specified and as directed.
PTMT waste coupling of 32 mm dia (half or full threaded) including taking down old coupling of any description complete all as specified and directed [Minimum weight for 32 mm – 45 gms].
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 500 ltrs complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 1000 ltrs capacity complete all as specified and as directed.
Rotational moulded polythene water storage tank (cylindrical vertical with closed top) with ISI mark embosed on it, hoisted and fixed in position complete all as specified in SSR part I capacity of tank 2000 ltrs capacity complete all as specified and as directed.
20mm bore dia Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed.(Minimum weight 2 0mm - 210 gms) all as specified and as directed.
Brass CP wall mixer for mixing hot & cold water screwed down for iron pipe 15 mm and fixed in repairs complete all as specified and as directed.
15mm dia angle cock, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions all as per Prayag Cat No PIS-7810 URBONA series or techno commercially equivalent makes specified in PS fixed in repairs all as specified and as directed.
15mm dia stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repairs complete all as specified and as directed.
125mm dia brass chromium plated shower rose with swivel joints fixed in repairs complete all as specified and as directed.
Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed. (Minimum weight 15mm-90gms) fixed in repairs complete all as specified and as directed.
Concussive push button taps of cast copper alloy, for 15mm dia of pipe, screwed for iron pipe and fixed in repairs fixed in repairs complete all as specified and as directed.
32 mm dia waste fittings, brass,chromium plated for sinks, basins,etc with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed
40 mm dia waste fittings,brass,chromium plated for sinks,basins,etc with long screwed shanks and flynuts, flange end fixed in repairs complete all as specified and as directed.
PVC corrugated waste pipe 40mm dia, 800mm long fixed in repairs complete all as specified and as directed.
PVC corrugated waste pipe 32mm dia, 800mm long fixed in repairs complete all as specified and as directed.
Health faucet, brass body with 1mtr SS braided rubber hose pipe & wall hook complete fixed in repairs all as specified and as directed(Cat log No: BEA -41 & 7812 of Prayag and equivalent make hindware and Cera)
Taking down existing bib taps, Pillar taps, stop cock or angle valve of any size and re fixing in old or new position including replacing one nylon washer complete all as specified and as directed.
All as per Sl Item No. 1.104 here-in-before but replacing brass spindle.
75 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
110 mm bore PVC (SWR) pipes, type 'B' single socketed in any length with rubber ring joints fixed to wall including PVC clamps and necessary fittings fixed in repairs complete all as specified and as directed.
75mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
110mm bore PVC (SWR) bends, type 'B' with access door complete all as specified and as directed.
75 mm bore PVC (SWR) junction single (single T), type 'B' equal or unequal complete all as specified and as directed.
110mm bore PVC (SWR) junction single (single T), type 'B' equal or unequal complete all as specified and as directed.
Water proofing treatment to sunken portion of WCs, bathroom and kitchen etc by applying cement slurry mixed with two component elastomeric acrylic based polymer modified cementitious composite compound coating of make as approved in TI 5/2003 including demolition and removal of existing treatment of any type with the following procedure in sequence all as specified and as directed:- (i) Demolition of existing treatment of any type including cleaning and removal of debris from site to outside MD land. (ii) First layer of cement slurry @ 0.488 kg/sqm of cement mixed with acrylic based polymer modified cementitious composite compound @ 0.253 kg/sqm, the layer will be allowed to air cure for 4 hours. (iii) Second layer of cement slurry @ 0.242 kg/sqm of cement mixed with with acrylic based polymer modified cementitious composite compound @ 0.126 kg/sqm, the layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. (iv) 20mm thick screed in cement mortar (1:3) mixed with including supply of liquid water proofing compound as per manufacturers instructions.
Contd/--1.112 (v) Ponding the treated portion atleast 48 hours, if any leakage / seepage observed the entire procedures will be repeated without any extra cost. (vi) Provide 40mm dia light grade GI spout at the lowest point with 30cm projection beyond the out face of the wall. (vi) A coat of 85/25 grade bitumen conforming to IS 702 : 1988 at the rate of l-5 kg/m should be applied. (vii) Sunken portion shall be filled with lean cement concrete(1:5:10), type E-2 using 40mm graded stone aggregate/brick bats concrete (1:5:10). NOTE :- (i) The sunken slab sloped towards outer face to drain the water in to GI spout pipe. (ii) Coving shall be provided at the junction of slab with the wall. (iii) Nahni trap shall be 10mm below finished floor level and drain pipe dia is larger than the nahni trap size. (iv) The outer end of the spout should be chamfered, Made of measure of measurement: floor/plan area willbe measured and paid.
Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples etc complete all as specified and as directed.
Demolition of cement concrete and paving not exc 15 cm thick (below or above ground level) complete all as specified and as directed.
Supply only liquid water proofing compound complete all as specified and as directed.
Rendering 5 mm thick on ceiling /RCC surfaces in cement mortar (1:3), finishing the surfaces even and smooth without using extra cement complete all as specified and as directed.
Preparing newly plastered ceiling surfaces of any description and applying three coats of white wash complete all as specified and as directed.
Plain Cement Concrete (1:2:4), type B-0 using 12.5 mm graded stone aggregate as in floors 25mm thick, as in sub base to floor complete all as specified and as directed.
Pre-polished machine cut Granite stone slab 18-20mm thick with edge rounded one side laid over and including 15mm thick cement mortar (1:4) screed laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
Kitchen sink made of stainless steel 1mm thick sheet with plugs, washers and wastes: including bedding in cement mortar to dwarf wall or including fixing cantilever brackets or fixing in granite slab and connecting union to pipe overall size 495mm x 420mm bowl size 410mmx 330mm x 160mm complete all as specified and as directed.
Stainless steel plate rack made out of of 0.63mm thick stainless steel sheet, over all size 800mm x 600mm with shape, capacity of utensiles and pattern complete fixed in repairs all as specified and as directed.
Bib taps, chromium plated sink cock regular spout (W/M) with flange 15mm dia fixed all as per Cat No-7816 URBONA series of Prayag or techno commercially equivalent make specified in PS fixed in repairs all as specified and as directed.
Cleaning of PVC/RCC over head water tanks at any height (on accessable / inaccessable roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus and any other bacterial material from sides/bottom of tank, cleaning shall be done by draining / pumping out water / sludge from bottom, by high pressure water jet of pressure rating not less than 120 PSI for removing clogged mud/scales etc and cleaning the same again with self priming pumped fresh water and disinfecting the water tank by using UV radiator and approved chemical (chlorite), after cleaning writing letters / figures (Date of cleaning and next Date of cleaning) on black back ground with white synthetic enamel paint including removing the existing letters/ figures complete all as specified and as directed for capacity of water tank exc. 250 litre and n.exc. 500 ltr capacity complete all as specified and as directed. NOTE FOR SL ITEM NO. 1.123 to 1.125 :- (i) Contractor has to ensure that there is no damage / leakage in tank after cleaning . (ii) Any air lock /blockage of water flow after cleaning will be made good immediately.
All as per Sl Item No. 1.123 above but capacity exc. 500 litre and n..exc. 1000 litre.
All as per Sl Item No. 1.123 above but capacity exc. 1000 litre and n..exc. 2000 litre.
Spraying antiweed / non toxic solution / chemicals containing Glyphosate as per manufacturer's instructions and removing the weed including the roots after ensuring complete de-germification of palnt / weed and cutting down the plant/trees off from roof/top sides of external walls of bldgs, in chajjas, wall junctions, junctions of GI/CI/AC/PVC pipes and taking out roots entered in wall/slabs, including making good the surface using PCC 1:2:4 type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface and repairing the pipes and joints which was affected by cutting down/taking out process all as specified and as directed for plants / trees located in the buildings upto first floor with necessary scaffolding, complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to execute the work of de-generated plant/weeds as per the prior approval and directions of Engineer-in-charge.
All as per Sl Item No. 1.127 above but from first floor to second floor.
All as per Sl Item No. 1.127 above but from second floor to third floor.
All as per Sl Item No. 1.127 above but from fourth floor and above.
Cleaning the roof /terrace of surface area exceeding 200 sqm but not exceeding 400 sqm at any height up to first floor (on accessible/inaccessible roofs) by removing all scale, dirt, mud, any foreign material, accumulated silt, other dirty substance, algae, fungus, leaves etc deposited over slab and making good the distrubed surfaces if any, with and including making good the surface using PCC (1:2:4), type B1 or cement mortar (1:2) or brick work in CM(1:4) plastered with CM(1:4) to match with existing surface and removing the material so obtained out side MD land complete all as specified and directed by Engineer-in-charge. NOTE:- Contractor has to submit the phtographic record of work done (before and after the work done duly noted the building No along with location) at the time of claiming the payment (RAR/final bill). No payments shall be be made without submiting the photographic records.
All as per Sl Item No. 1.131 above but upto second floor.
All as per Sl Item No. 1.131 above but upto third floor.
All as per Sl Item No. 1.131 above but upto fourth floor and above.
Taking down eaves gutters and rainwater pipes (any size or pattern), including all fittings, heads, shoes, bends, swan-necks, etc.,including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fitting and accessories)
Stainless steel pipe holding clamp 150 mm long for PVC pipe upto 110 mm dia pipe fixed with stainless screw including removing and refixing of pipe/new pipe including necessary scaffolding up to four story building complete all as specified and as directed.
Preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds , moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or Plaster of Paris and applying one coat distemper oil emulsion, white or tinted etc complete all as specified and as directed
Preparation of plastered or un plastered old decorated surfaces of walls by brooming down or with steel wire brushing, scraping down smoke soot’s, moulds, moss & efflorescent salts & treating oily & greasy spots & filling holes & cracks with suitable material like white cement or plaster of paris and applying two coats distemper oil emulsion, white or tinted over two coats of wall care putty over a coat of primer complete all as specified and as directed.
Preparing of old painted surfaces of wood and wood based surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Preparation of old painted steel surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
FRP pre fabricated chajja up to 600 mm width & 1.20 m long including cutting of old renforced RCC chajja with making surfaces good and smooth by making throting and water cutter up to four story building with necessary scaffolding complete all as specified and as directed.
SRI MAHALAKSHMI CONSTRUCTIONS
kamadhenu Electricals
K V RAJANNA
ANAND REFRIGERATION
Suneetha Engineers and Contractors
ASCEND INFRA
DHANUSH CONSTRUCTIONS CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .