| Sl No | Description | Qty | Unit | M/s Sharada Electricals L3 | NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER L2 | SINLESS ELECRICAL CO. PVT. LTD. L1 |
|---|---|---|---|---|---|---|
| 1.00(A) Safe loading & carriage including Loading-unloading & proper stacking of following store materials from ESC Tripula to site of work. | ||||||
| 1.01 | S.T. Pole 11 Mtr. Long | 429 | No | 650 ₹2,78,850 | 500 ₹2,14,500 Lowest | 500 ₹2,14,500 Lowest |
| 1.02 | 11 KV M.S. Top Channel (100x50x6) 2240 mm | 118 | No | 70 ₹8,260 | 50 ₹5,900 Lowest | 50 ₹5,900 Lowest |
| 1.03 | 11 KV M.S. Dropper Channel (100x50x6) 2240 mm | 110 | No | 70 ₹7,700 | 50 ₹5,500 Lowest | 50 ₹5,500 Lowest |
| 1.04 | 11 kV Disc Insulator 45 KN | 519 | No | 10 ₹5,190 Lowest | 10 ₹5,190 Lowest | 10 ₹5,190 Lowest |
| 1.05 | 11 kV Disc fitting 45 KN | 519 | No | 10 ₹5,190 Lowest | 10 ₹5,190 Lowest | 10 ₹5,190 Lowest |
| 1.06 | Earthing Complete | 396 | No | 25 ₹9,900 Lowest | 50 ₹19,800 | 50 ₹19,800 |
| 1.07 | 11 kV (3 x 185) sqmm XLPE cable | 13,300 | Mtr. | 35 ₹4,65,500 | 10 ₹1,33,000 Lowest | 10 ₹1,33,000 Lowest |
| 1.08 | H.S. Cable jointing kit for 11 KV (3 x 185) sqmm cable Outdoor/Indoor type. | 140 | No | 65 ₹9,100 | 50 ₹7,000 Lowest | 50 ₹7,000 Lowest |
| 1.09 | 11 KV (3 x 185) sq mm straight through cable Jointing Kit. | 42 | No | 65 ₹2,730 | 50 ₹2,100 Lowest | 50 ₹2,100 Lowest |
Tender Value
₹4.5 Cr
EMD Value
₹4.5 L
Closing Date
4 Apr 2022, 3:00 pmClosed
SE EDC-II RAEBARELI
SE EDC-II RAEBARELI
WORK MENTIONED IN BOQ
2022_MVVNL_682683_1
164/EDC-II,R/2021-22
Open Tender
Electrical Works
Item Wise
60 days
UNDER EDD- UNCHAHAR, RAEBARELI
Please refer Tender documents.
2 documents required · 2 mandatory
₹5,900
EX ENGINEER ETD-II GORA BAZAR RAEBARELI
₹4.5 L
Yes
SE EDC-II, GORA BAZAR RAEBARELI
7 Apr 2022
29 Mar 2022
5 Apr 2022
29 Mar 2022
4 Apr 2022
29 Mar 2022
2 Apr 2022
Amount
(A) Safe loading & carriage including Loading-unloading & proper stacking of following store materials from ESC Tripula to site of work.
S.T. Pole 11 Mtr. Long
11 KV M.S. Top Channel (100x50x6) 2240 mm
11 KV M.S. Dropper Channel (100x50x6) 2240 mm
11 kV Disc Insulator 45 KN
11 kV Disc fitting 45 KN
Earthing Complete
11 kV (3 x 185) sqmm XLPE cable
H.S. Cable jointing kit for 11 KV (3 x 185) sqmm cable Outdoor/Indoor type.
11 KV (3 x 185) sq mm straight through cable Jointing Kit.
11 kV Fuse set
11 KV V type cross arm
H.S. Cable jointing kit for 33 kV (3 x 300) sqmm cable Outdoor/Indoor type
11 KV Pin insulator
11 KV GI pin with nut
T off channel (100 x 50 x 6) 1300 mm
M.S. Angle (65 x 65 x 6) for brassing with 04 clamp
T/F Base angle set
ACSR Dog conductor
33 KV disc insulator B&S type 70 KN
Disc fitting 70 KN
33 KV Stay set (20 X 1800) mm with stay wire, stay clamp, insulator , nut & bolt etc.
11 KV Stay set (16 X 1800) mm with stay wire, stay clamp, insulator , nut & bolt etc.
33 kV (3 x 300) sq mm XLPE cable
33 KV (3 x 300) sq mm straight through cable Jointing Kit.
33 KV M.S. Top Channel (125x65x6) 3200 mm
33 KV M.S. Dropper Channel (125x65x6) 3000 mm
33 KV Pin insulator
33 KV GI pin with nut
LT Cable 4x120 sqmm
F Clamp
11 KV TPMO SET
G.I. wire 8/10/16 SWG
33 kV (3 x 300) sq mm XLPE cable
guarding angle
LT Cable 3.5x70 sqmm
LT Cable 3.5x400 sqmm
(B) Work
Fabrication, erection & painting of S.T. Pole 11 Mtr long of Single pole on ST pole 11 M long with fixing of necessary clamps and other accessories required for erection.
Fabrication, erection & painting of Double pole cable exposure on S.T. Pole 11 Mtr long with fixing of channel , angle pin & pin insulator,D.O set and making bus bar complete work with earthing by earth rod 20x2500 mm for 11 KV Line as per RESSPO drawings.
Grouting & Plinthing of single ST pole as per RESPO Norms (0.268 Cum)
Installation of cable box 11 KV (3 x 185) sq mm Outdoor/Indoor
Installation of cable box 33 KV (3 x 300) sq mm Outdoor/Indoor
Installation of cable box 11 KV straight through (3 x 300) sq mm
Installation of cable box 33 KV straight through (3 x 300)/ (3x400) sq mm
Laying of 11 KV (3 x 185) sq. mm double circuit XLPE Cable in HDPE pipe PN-6, 6" dia by horizontal deep with drilling method (All materials will be suppllied by the contractor at his own cost except XLPE cable.) (Total length of cable =4020x2 (double circuit)=8040 Mtr.)
Laying of 11 KV (3 x 185) sq. mm XLPE Cable by digging of trench 1.2 mtr deep vide as per ISS in HDPE pipe PN-6, 6" dia including providing bricks, sand, stone slab the inter exel spacing bettween to cable shoulde be in between 0.25 m to 0.40 m as required at site as per RESPO Norms.
Stringing & sagging of three phase 11 KV line on ACSR Dog conductor as per RESSPO Norms.
Stringing & sagging of three phase 33 KV line on ACSR Dog conductor as per RESSPO Norms.
Fixing of earth rod (2500 x 20) mm as per norms. For earthing support of old existing poles of LT lines including 6 SWG GI/Earth wire . (All Materials provided by contractor)
Nozeling & grouting of 11 KV stay set complete.(All the civil material will be be provided by Contractor)
Nozeling & grouting of 33 KV stay set complete.(All the civil material will be be provided by department.)
Placement of 11/0.4 KV T/Fs on S/S Type D/P &installation, commissioning of 25 KVA to 100 KVA T/F including cost of L-pieces and lugs jumpering with the system with painting as per RESSPO norms. ( All the required martial for above job shall be provided by contractor except T/Fs)
High Pressure testing of 33 KV & 11 KV XLPE cable. Testing equipment will be arranged by the contractor.
33 KV cable
11 KV cable
Dismantling of 11KV line, L.T. lines & distribution boxes and its dump at suitable place on site up to completion of work and its safe loading/unloading/weighing carriage from dump site to je"s store/ESC Raebareli (Except broken PCC Pole).
ST Pole 11 Mt Long/PCC pole
ACSR mix conductor
Steel scrape
Stringing & sagging of three phase 4 wire LT line on ACSR Dog conductor as per RESSPO Norms.
Laying of 33 KV (3 x 300)sq. mm double circuit XLPE Cable in HDPE pipe PN-6, 6" dia by horizontal deep with drilling method (All materials will be suppllied by the contractor at his own cost except XLPE cable.) (Total length of cable =1600x2 (double circuit)=3200 Mtr.)
Laying of LT Cable (3.5 x 400)sq. mm double circuit XLPE Cable in HDPE pipe PN-6 6" dia by horizontal deep with drilling method (All materials will be suppllied by the contractor at his own cost except XLPE cable.) (Total length of cable =1635x2 (double circuit)=3270 Mtr.)
(C) Following Metarials to be supplied by contractor:-
Nut and bolt off size
PG clamp
Stone Pad
Number Plate
Danger Board with clamp
G.I. barbed wire
Alumineum Binding wire 6 SWG
Aluminium Paint
Red Oxide paint
G.I. Pipe 8 inch
G.I. Pipe 6 inch
Earthwire clamp with Nut and bolt
LT Shackle Insulator
Loop Guard complete 3 Phase
Aluminium Jointing Sleevs for conductor
LT PVC Spacer
LT incomming panel with metering equipment and fixing arrangment
LT Shackle Insulator strip with nut and bolt
X-arm holding clamp/ LT clamp/Top/Dropper/T Off with bolt & nut for STP
HDPE Pipe PN-6, 6" dia. (Purchased from the approved venders of UPPCL)
NATIONAL CONTRACTOR & GENERAL ORDER SUPPLIER
M/s Sharada Electricals
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.06 MB
164unchahar.pdf
Tender Documents • 1.36 MB
BOQ_1088796.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .