Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.4 LAccepted-AOC NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹70.1 L+₹1.2 L (1.76%)Rejected-Finance SR NO 281 3 7 ANAND NAGAR NEAR DHANORI JAKAT NAKA LOHEGAON PUNE 411047 | PUNE | PUNE | MAHARASHTRA | 411047 | L2 | Rejected-Finance NOT BEING LOWEST | |
| 3 | L3₹77.3 L+₹8.4 L (12.2%)Rejected-Finance 26 3 3RD CROSS GANESHA BLOCK SULTANPALYA RT NAGAR POST BANGALORE 560 032 | BANGALORE | BANGALORE | KARNATAKA | 560032 | L3 | Rejected-Finance NOT BEING LOWEST | |
| 4 | L4₹86.9 L+₹18.0 L (26.1%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BENGALURU URBAN | KARNATAKA | 560085 | L4 | Rejected-Finance NOT BEING LOWEST |
| Sl No | Description | Qty | Unit | Lucky Enterprises L4 | G K CONSTRUCTIONS L3 | VP DEVELOPERS AND CONTRACTOR L2 | M/S SIRI BUILDERS L1 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sqm and below complete all as specified and as directed | 6 | EACH | 350 ₹2,100 | 400 ₹2,400 | 110 ₹660 Lowest | 380 ₹2,280 |
| 2.00 | Supply and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer in charge | 27 | RUNNING METRE | 580 ₹15,660 | 400 ₹10,800 | 389 ₹10,503 Lowest | 460 ₹12,420 |
| 3.00 | Supply and fixing factory made panel PVC door shutter 30mm thick consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail and bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles and rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading Code Description Unit Rate No. SUB HEAD : 9.0 WOOD AND P.V.C. WORK 201 on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge and manufacturer's specification and drawing | 10 | SQUARE METRE | 4,250 ₹42,500 | 3,900 ₹39,000 | 3,110 ₹31,100 Lowest | 3,450 ₹34,500 |
| 4.00 | Taking down, easing, adjusting and refixing door shutters after laying of tiles, any description exc 1 Sqm but n. exc 2 Sqm each in the same opening complete all as specified and as directed. | 6 | EACH LEAF | 450 ₹2,700 | 400 ₹2,400 Lowest | 400 ₹2,400 Lowest | 470 ₹2,820 |
| 5.00 | Supply and fixing aluminium tower bolt 150X 10 mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and as directed | 12 | EACH | 180 ₹2,160 | 150 ₹1,800 | 110 ₹1,320 Lowest | 126 ₹1,512 |
| 6.00 | Supply and fixing aluminium handles 125mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and as directed | 12 | EACH | 100 ₹1,200 | 150 ₹1,800 | 95 ₹1,140 Lowest | 180 ₹2,160 |
| 7.00 | Supply and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws of size 100x58x1.90 mm complete all as specified and as directed | 18 | EACH | 140 ₹2,520 | 100 ₹1,800 | 75 ₹1,350 Lowest | 85 ₹1,530 |
| 8.00 | Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) aluminium frame work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. | 370 | KILO GRAM | 690 ₹2,55,300 | 670 ₹2,47,900 | 630 ₹2,33,100 Lowest | 640 ₹2,36,800 |
| 9.00 | Supply and fixing for shutters of doors, windows and ventilators Powder coated aluminium (minimum thickness of powder coating 50 micron) including Supply and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) complete all as specified and as directed | 210 | KILO GRAM | 680 ₹1,42,800 | 690 ₹1,44,900 | 650 ₹1,36,500 Lowest | 680 ₹1,42,800 |
| 10.00 | Supply and fixing for 4mm thick Figured glass, pin head type and glazing area n exc 0.5 sq. m in each pane fixing to Aluminium ventilators complete all as specified and directed. | 25 | SQUARE METRE | 1,100 ₹27,500 | 999 ₹24,975 | 1,000 ₹25,000 | 920 ₹23,000 Lowest |
Tender Value
₹85.5 L
EMD Value
₹1.5 L
Closing Date
18 Aug 2025, 6:00 pmClosed
GE I RnD East Bangalore
GE I RnD East Bangalore DRDO complex CV raman Nagar Bangalore 93
ADDITION ALTERATION TO BLDG P 71 P 10 P 8 AT RTC AND 11 NOs UG SUMP AT ADE PROVN OF SHED FOR DG SET AND ENTRY GATE AT RTC UNDER GEI RnD EAST BANGALORE
2025_MES_693744_3
8570/E8
Open Tender
Civil Works
Item Rate
150 days
BANGALORE
Class C Category a(i)
8 documents required · 8 mandatory
₹1,000
Yes
GE I RnD East Bangalore
₹1.5 L
Yes
12 Sept 2025
29 Jul 2025
25 Aug 2025
29 Jul 2025
18 Aug 2025
6 Aug 2025
29 Jul 2025 - 4 Aug 2025
Amount
Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead of area 3 sqm and below complete all as specified and as directed
Supply and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer in charge
Supply and fixing factory made panel PVC door shutter 30mm thick consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top and bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail and bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles and rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading Code Description Unit Rate No. SUB HEAD : 9.0 WOOD AND P.V.C. WORK 201 on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge and manufacturer's specification and drawing
Taking down, easing, adjusting and refixing door shutters after laying of tiles, any description exc 1 Sqm but n. exc 2 Sqm each in the same opening complete all as specified and as directed.
Supply and fixing aluminium tower bolt 150X 10 mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and as directed
Supply and fixing aluminium handles 125mm, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete all as specified and as directed
Supply and fixing ISI marked M.S. pressed butt hinges bright finished with necessary screws of size 100x58x1.90 mm complete all as specified and as directed
Supply and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) aluminium frame work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.
Supply and fixing for shutters of doors, windows and ventilators Powder coated aluminium (minimum thickness of powder coating 50 micron) including Supply and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) complete all as specified and as directed
Supply and fixing for 4mm thick Figured glass, pin head type and glazing area n exc 0.5 sq. m in each pane fixing to Aluminium ventilators complete all as specified and directed.
Supply and fixing 20 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings and fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge.
Supply and fixing 25 mm nominal dia Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fitting with one step CPVC solvent cement, trenching, refilling and testing of joints complete as per direction of Engineer in Charge.
Supply and fixing on wall face unplasticised Rigid PVC rain water pipes 110 mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes complete all as specified and as directed
Taking down rainwater pipes (any size or pattern) , including all fittings, heads, shoes, bends, swan-necks,etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed
Supply and fixing on wall face unplasticised Rigid PVC rain water pipes 75 mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, Single socketed pipes complete all as specified and as directed
Supply and fixing Rigid PVC(SWR) bend, type 'B' 75 mm dia all as specified and directed.
Supply and fixing Rigid PVC junction single 'T' equal or unequal 75 mm bore with access door complete all as specified and directed.
Supply and fixing Rigid PVC(SWR) junction single 'T' equal or unequal 110 mm bore with access door type 'B' complete all as specified and directed.
Supply and fixing PVC(SWR) vent cowl type 'B' 75mm bore all as specified and as directed.
Supply and fixing PVC (SWR) branch piece, single (single Y) equal or unequal type 'B' 110mm dia with access door complete all as specified and directed.
Supply and fixing Rigid PVC(SWR) Shoe 75 mm dia type 'B' all as specified and directed.
Supply and fixing Rigid PVC(SWR) Shoe 110 mm dia type 'B' all as specified and directed.
Demolishing cement concrete in roof padding,terrazo flooring, sunken floor etc in any situation manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge
Material and labour for PCC 1:2:4 (1 Cement : 2 coarse sand derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) in roof padding, kerbs etc complete all as specified and as directed
Material and labour for cleaning the surface by use of wire brush, Water jet and grinding etc to remove all loose dust, Fungus oils grease etc.All the existing membrane and primer and other foreign particles shall be removed by Grinding and other mechanicals means completely to reach base slab, complete all as specified and directed.
Material and labour for cutting V shaped groove over the cracks and filling the same with Dr. Fixit PU sealant and Pidiprime A , for deeper cracks suitable backerrod shall be provided complete all as specified and as directed
Material and labour for priming with 1 coat of Dr. Fixit Prime seal diluted with clear water at a ratio of 2:1 and allowing it to dry got a minimum of 6 hours. (Dr Fixit Roofseal Ultra plus for Terrace) complete all as specified and directed.
Material and labour for PCC 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) in sunken floors etc and work above plinth level complete all as specified and directed.
Material and labour for PCC 1:2:4 (1 Cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources complete all as specified and directed.
Supply only liquid water proofing compound of approved and as directed
Supply and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry etc complete all as specified and as directed
Supply and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc including dismantling of old tiling work complete all as specified and as directed.
Supply and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados etc over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade including dismantling of old tiling work complete all as specified and as directed.
Material and labour for 50 mm thick cement concrete type C2, 1:3:6 ,using 40mm graded aggregate as in flooring etc finishing cement concrete surface even and smooth without using extra cement complete all as specified and directed.
Supply and fixing Corner glass shelf assembly consisting of 5.5mm thick sheet glass of 25cm wide with chromium plated bracket guard and fixed with CP screws and wood cleats with wall complete all as specified and directed.
Supply and fixing for Powder coated Stainless steel 6 hook peg stay fixing with screws complete all as specified and directed.
Supply and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete all as specified and directed.
Supply and fixing in repair cabinet mirror moulding theremoset litron formaldehyde of plientil formaldehyde with chromium plated frame openable type and mirror colour white complete all as specified and directed.
Supply and fixing 15 mm nominal bore with 45 cm length unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour, complete fixed in repair complete all as specified and directed.
Supply and fixing 75mm dia outlet PVC multi floor trap with grating including dismantling the damaged trap all as specified and as directed.
Supply and fixing in repairs PVC floor trap with plain/single hole CP grating including jointing to waste pipe of outlet 75 mm.dia in cement joint, complete all as specified and directed.
Supply and fixing in repairs 75mm dia outlet PVC Nahani trap with grating complete all as specified and as directed.
Supply and fixing in repair Chromium plated wall mixer four way with single lever telephonic shower as fixed to 15 mm bore pipe all as specified and as directed,
Material and labour for precast cement concrete cover slab for sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand),cost of required Centering complete with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural source) complete size derived from natural sources coarse sand) complete all as specified and directed.
Supply and fixing Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding with Thermo-Mechanically Treated bars of grade Fe-500D or more complete all as specified and directed.
Supply and fixing stainless steel ( Grade 304) railing/grills made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories and stainless steel dash fasteners , stainless steel bolts etc., of required size with suitable arrangement as per approval of Engineer-in?chargcomplete all as specified and as directed. Note: for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.
Supply and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required for gratings, frames, guard bar, ladder, railings, brackets, gates and similar works complete all as specified and as directed
Supply and placing on terrace (at all floor levels) 500 ltrs capacity polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support complete all as specified and directed.
Supply and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats 20 mm nominal bore complete all as specified and directed
Supply and fixing in repairs 20mm dia Gun metal Gate valves with iron wheel head, screwed both ends for iron pipe and fixed including cutting the old pipes complete all as specified and directed
Supply and fixing 15 mm nominal bore C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931 complete all as specified and directed.
Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge.
Material and labour for Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5, straight or curved in plan exc 6m mean radius in superstructure above plinth level up to floor V level with Cement r mortar 1:6 (1 cement :6 coarse sand) complete all as specified and directed.
Material and labour for Salt glazed stone ware gully traps square or round mouthed type 'P' of size 150 x 150 mm including taking roviding and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design including 180x150 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 complete all as specified and as directed
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed.
Material and labour for 15mm thick rendering on brick, solid block or concrete surface in cement mortar 1:4 (1 cement: 4 fine sand) and finishing the surface with even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately
Material and labour for 15mm thick rendering on brick or concrete surface in cement mortar 1:6 and finishing the surface with even and smooth without using extra cement all as specified of cement of mix 1:6 (1 cement: 6 fine sand) complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately
Material and labour for 5mm thick rendering on ceilings in cement mortar 1:3 and finishing the surface with even and smooth without using extra cement all as specified and as directed.
Material and labour for Distempering with oil bound washable distemper of approved brand, tint and manufacture to give an even shade on new work of ceiling surface (two or more coats) over and including water thinnable priming coat with cement primer complete all as specified and as directed.
Material and labour for Distempering with oil bound washable distemper of approved brand, tint and manufacture to give an even shade on new work of wall surface (two or more coats) over and including water thinnable priming coat with cement primer and 2 mm thick putty of approved complete all as specified and directed.
Material and labour for finishing walls with Premium Acrylic Smooth exterior paint of approved tint with Silicone additives of required shade over old surfaces (Two or more coats applied @ 1.43 ltr/ 10 sqm) including preparation of surface and 1mm average thickness wall putty to prepare the surface even and smooth complete all as specified and as directed
Material and labour for Painting with synthetic enamel paint of approved brand, tint and manufacturer to give an even shade of two or more coats on new work of steel surface over a coat of approved primer including preparation of surface complete all as specified and directed.
Material and labour for Painting with synthetic enamel paint of approved brand, tint and manufacturer of required colour to give an even shade of one or more coats on steel surface of old work including preparation of surface complete all as specified and directed.
Material and labour Washing, rubbing down and stopping of distempered and painted surfaces of old distempered surfaces and applying two coat of distemper oil emulsion of approved tint on ceiling surfaces complete all as specified and as directed by Engineer-in-Charge.
Material and labour Washing, rubbing down and stopping of distempered and painted surfaces of old distempered surfaces and applying two coat of distemper oil emulsion of approved tint on wall surfaces complete all as specified and as directed by Engineer-in-Charge.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete and applying white cement based putty of average thickness 1 mm, of approved brand, tint and manufacturer, over the plastered wall/ ceiling surface to prepare the surface even and smooth complete and apply two coats of distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacturer, including applying additional coats wherever required, to achieve even shade and colour complete all as specified and as directed
Material and labour for plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth complete all as specified and as directed
Material and labour for mild steel rolled structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete all as specified and directed
Excavating holes more than 0.10 cum and upto 0.5 cum including getting out the excavated soil, then returning the soil as required in layers not exceeding 20cm in depth, including consolidating each deposited layer by ramming, watering etc, disposing of surplus excavated soil, as directed within a lead of 50 m and lift upto 1.5 m complete all as specified and directed
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m complete all as specified and directed
Supply and providing precoated galvalume corrugated G.S. sheet roofing 0.63 mm thickness with zinc coating not less than 275 gm/sqm including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and as directed
Material and labour for painting for steel work with synthetic enamel paint of approved tint to give an even shade, two or more coat applied @ 0.90 ltr/10 Sqm over an under coat of primer applied @ .80 ltr/ 10 Sqm of approved brand and manufacture complete all as specified and directed.
Material and labour for White washing with lime to give an even shade on wall surface (two or more coats) including preparation of surfaces complete all as specified and directed.
Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 metres lead of area 3 sqm and below complete all as specified and directed.
Supply and fixing G.I. pipes 15mm nominal dia of bore with G.I. fittings and clamps, incl. cutting and making good the walls etc complete all as specified and as directed
Supply and fixing G.I. pipes 20mm nominal dia of bore with G.I. fittings and clamps, incl. cutting and making good the walls etc complete all as specified and as directed
Material and labour for Cutting holes in brick walls or stone walls built in cement mortar for inserting holdfasts and making good dismantled portion with cement mortar 1:3 or cement concrete 1:2:4 Type B-1 as required complete all as specified and as directed
Material and labour for Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level with Cement mortar 1:4 (1 cement :4 coarse sand) including extra for providing and placing in position 2 Nos of 6mm dia. M.S. bars at every third course of half brick masonry complete all as specified and as directed
Material and labour for 15 mm thick rendering in CM 1 : 4 on rough faces of brick work or concrete surfaces mixed with water proofing compound complete all as specified and directed
Material and labour for removing the existing finishes and applying two coat of Multi faceted texture metallic finishes, royale play pastels special effects paints finishes, base coat as royal luxury emulsion, top coat royale play / royale play metallic special effects after 3mm thick wall care putty complete all as specified and directed.
Material and labour for 25mm thick Kota stone slab in flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) including dismantling of old tiling work complete all as specified and as directed.etc all as specified and as directed
Supply and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab is over 0.50 sqm , Granite stone slab colour black, Cherry/Ruby red complete all as specified and as directed
Material and labour for edge moulding to 18 mm thick granite stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars in slabs and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge.
Material and labour for 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources complete all as specified and as directed
Material and labour for RCC M25 grade (Design Mix) Concrete of M25 grade as in wall/slab/raft etc with minimum cement content of 300 kg /cum Providing and laying in position ready mixed or site batched design mix cement concrete using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland / Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting using 20mm graded stone aggregate as in foundations, including rafts footings etc; complete. of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the Engineer-in-charge NOTE : Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement
Material and labour for centering and shuttering including strutting, propping etc. and removal of form work for Foundations, footings, bases for columns complete all as specified and as directed
Material and labour for centering and shuttering including strutting, propping etc. and removal of form for Suspended floors, roofs, landings, balconies and access platform complete all as specified and as directed
Material and labour for centering and shuttering including strutting, propping etc. and removal of form work for Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc.complete all as specified and as directed
Material and labour for centering and shuttering including strutting, propping etc. and removal of form for Edges of slabs and breaks in floors and walls etc. for under 20 cm wide complete all as specified and as directed
Removing excavated material exc. 1.50 km but n exc. 5 km and depositing where directed
Material and labour for 75mm thick plinth protection of cement concrete 1:3:6 (1 cement: 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling and dressing and finishing the top smooth complete all as specified and as directed
Supply of integral water proofing compound .
Material and labour for filling with available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m complete all as specified and as directed
Dismantling G.I. pipes of dia above 40mm (external work) including excavation and refilling trenches after taking out the pipes, manually/ by mechanical means including stacking of pipes within 50 metres lead as per direction of Engineer-in-charge
Material and labour for refixing of old dismantled GI pipe line, of dia above 40mm in same opening/location including necessary fittings as well as thread/tape/sealant and as directed by EIC.
Material and labour for ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 50 mm nominal bore complete all as specified and as directed
Material and labour for finishing walls with water proofing epoxy tri block cementious coating paint of required shade on new plastered surface work (Two or more coats applied @ 3.84 kg/10 sqm)all as per manufacturer instructions complete all as specified and as directed
Material and labour for preparation of new plastered surface of walls including Washing, rubbing down and stopping of painted surfaces and applying two coat of cement base paint, complete all as specified and directed.
Material and labour for Point wiring complete with multi stranded copper conductor size 1.5 Sqmm PVC insulated, sheathed FRLS cable 1100 volts grade conforming to IS 694 multistranded , drawn in and including cutting wall /surface with rigid PVC conduit flushed on walls/floors / ceiling etc with and including metal flush boxes of suitable size and modular white plate with frame for mounting of fittings, modular type switches , regulator and also including 1.5 Sqmm PVC insulated sheathed copper cable green in colour as continuous earth continuity conductor and connecting to earth dolly, cutting chasis to the walls /floors/ceilings and repairing with existing surface after work complete all as specified and directed by Engr in charge. (a) One light/fan point controlled by one 5 Amps one way switch using cable (1.5 Sq mm for phase and neutral and 1.5 sqmm for earthing).
Material and labour for Wiring for light/ power plug with 2X1.5 sq. mm FRLS PVC insulated copper conductor single core cable in concealed/surface/ recessed medium class PVC conduit alongwith 1 No. 1.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required for 5 A socket on independent board complete all as specified and directed.
Material and labour for Wiring for light/ power plug with 2X4 Sq mm FRLS PVC insulated copper conductor single core cable in concealed/surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 15 A power plug complete all as specified and directed.
Supply and fix suitable size GI box with modular plate and cover in front on surface or recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 modular switch connections etc are required complete all as directed by Engr-in-charge.
Supply and fix suitable size GI box with modular plate and cover in front on surface or recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 modular switch connections etc are required complete all as directed by Engr-in-charge.
Supply and fix ceiling rose surface backelite two to three terminal complete all as directed.
Supply and fix stepped electronic fan regulator modular type 100 watt, 230 volt including removing old regulator any type complete all as directed.
Material and labour for sub main wiring complete with 2 runs of 10 Sqmm PVC insulated and sheathed cable with multistranded copper conductor confirming to IS-649, 1100 volts grade and drawn through and including PVC non metallic rigid conduits/Existing conduit and conduit accessories concealed / run on surface of wall/floors/ ceiling etc and connecting terminal ends including 1 run of 6 Sqmm of PVC insulated sheathed copper conductor cable green colour as continuous earth continuity conductor and connecting to earth dolly including removing unserviceable sub main wiring complete all as directed and specified by Engr in charge.
Supply and fix in replacement MCB DB SPN 8 Way 240 volts single phase double door with 200 amps rated aluminium bus bar complete all as specified and directed.
Supply and fix in replacement MCB SPN 63 Amps 10kA 415 Volts three phase complete all as specified and directed.
Supply and fix in replacement MCB SP 6 to 32Amps 10kA 240 Volts single phase complete all as specified and directed..
Supply and fix recessed mounted 2' X 2', 36 W soft glow flat panel including all accessories and fixing arrangement for fixing the light fitting to ceiling including taking down existing fitting all as specified and directed.
Supply and fix LED batten fitting surface mounted of 20 Watts, 4 feet, extruded aluminium housing high lumen output with accessories complete all as specified and directed .
Supply and fix LED mirror light fitting surface mounted of capacity of 10W with plastic body and accessories complete all as specified. including connecting to ceiling rose with twin copper conductor of size 0/0.24 complete all as specified and directed
Supply and fix in repair Ceiling fan of size 1200 mm sweep, energy saving model, AC single phase, 240 V including down rod,necessary connection with flexible copper cable from ceiling rose complete all as specified and as directed.
Supply and fix heavy duty exhaust fan,metal body, AC single phase, 240 V of size 300 mm sweep,1400 RPM with louvers including necessary connection and replacement of flexible copper cable from ceiling rose complete all as specified and as directed.
Material and labour for making hole on wall for 300 mm exhaust fan 300 mm incl plastering and painting to match with existing colour complete all as specified and directed
Material and labour for Wiring for light/ power plug with 2X2.5 Sq mm FRLS PVC insulated copper conductor single core cable in concealed/surface/ recessed medium class PVC conduit alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 15 A power plug complete all as specified and directed
Supply and fix energy efficient LED Batten fitting 22 Watts surface mounted with extruded aluminium housing with diffuser complete all as specified and directed by Engr in Charge.
VP DEVELOPERS AND CONTRACTOR (BID ID -3389966)
G K CONSTRUCTIONS (BID ID -3396726)
Lucky Enterprises (BID ID -3390036)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .