| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 CrAccepted-AOC | ₹3.2 Cr Quoted ₹3.3 Cr | L1 | Accepted-AOC LOWEST BIDDERER. |
| 2 | L2₹3.4 Cr+₹12.5 L (3.83%)Rejected-AOC | ₹3.4 Cr+₹12.5 L (3.83%) | L2 | Rejected-AOC NOT LOWEST BIDDERER. |
| 3 | L3₹3.4 Cr+₹14.1 L (4.32%)Rejected-AOC | ₹3.4 Cr+₹14.1 L (4.32%) | L3 | Rejected-AOC NOT LOWEST BIDDERER. |
Tender Value
₹3.1 Cr
EMD Value
₹3.9 L
Closing Date
12 Jun 2020, 6:00 pmClosed
CHIEF ENGINEER AF NAGPUR
HQ CHIEF ENGINEER AF, VAYUSENA NAGAR, NAGPUR 440007
PROVISION OF GASTRO ENTROLOGY CENTRE WITH PROCEDURE AND INTERVENTION LAB AT 7 AF HOSPITAL, KANPUR
2020_MES_343003_1
CA NO. CE (AF)/NGP/CHK/ OF 2019-20 800131/E
Open Tender
Civil Works
Lump-sum
GE AF BR CHAKERI
Class A cat a i
8 documents required · 8 mandatory
₹2,000
Yes
GE AF BR CHAKERI
₹3.9 L
Yes
10 Jul 2020
8 May 2020
15 Jun 2020
8 May 2020
12 Jun 2020
22 May 2020
Amount
Lumpsum price worked out by the contractor for “BUILDINGS AND STRUCTURES” as listed in Sch 'A' part I above/below the lumpsum price of Rs. 11290000.00 as inserted by MES for Sch ‘A’ part I on srl page No. 28.
Lumpsum price worked out by the contractor for “SITE CLEARANCE/DEVELOPMENT AND EARTHWORK” as listed in Sch '‘A” part II above/below the lumpsum price of Rs. 4,82,333.78 as inserted by MES for Sch ‘A’ part II on srl page No.30.
Lumpsum price worked out by the contractor for “INTERNAL WATER SUPPLY” as listed in Sch '‘A” part III above/below the lumpsum price of Rs. 33,244.50 as inserted by MES for Sch ‘A’ part III on srl page No.31.
Lumpsum price worked out by the contractor for “INTERNAL ELECTRIFICATION” as listed in Sch '‘A” part IV above/below the lumpsum price of Rs. 77173.50 as inserted by MES for Sch ‘A’ part IV on srl page No.32
Lumpsum price worked out by the contractor for “ROAD/PATH/HARDSTANDING" as listed in Sch ‘A” part V representing above/below the lumpsum price of Rs. 228666.25 inserted by MES for Sch ‘A’ Part V on srl page No.33.
Lumpsum price worked out by the contractor for “EXTERNAL WATER SUPPLY" as listed in Sch ‘A” part VI representing above/below the lumpsum price of Rs. 25850.30 inserted by MES for Sch ‘A’ Part VI on srl page No.34
Lumpsum price worked out by the contractor for “EXTERNAL ELECTRIC SUPPLY" as listed in Sch ‘A” part VII representing above/below the lumpsum price of Rs. 381642.60 inserted by MES for Sch ‘A’ Part VII on srl page No.35
Lumpsum price worked out by the contractor for “AIR CONDITIONING" as listed in Sch ‘A” part VIII representing above/below the lumpsum price of Rs.464320.00 inserted by MES for Sch ‘A’ Part VIII on srl page No.36
Lumpsum price worked out by the contractor for “FIRE DETECTION & ALARM SYSTEM” as listed in Sch ‘A” part IX representing above / below the lumpsum price of Rs. 433816.00 as inserted by MES for Sch ‘A’ Part IX on srl page No.37
Lumpsum price worked out by the contractor for “SEWAGE DISPOSAL” as listed in Sch ‘A” part X representing above / below the lumpsum price of Rs.97420.46 as inserted by MES for Sch ‘A’ Part X on srl page No.38
Lumpsum price worked out by the contractor for “AREA DRAINAGE” as listed in Sch ‘A” part XI representing above / below the lumpsum price of Rs.68564.30 as inserted by MES for Sch ‘A’ Part XI on srl page No. 39
SCH 'A' PART XII(MISC B/R & E/M ITEMS) Note:- Excavation and earthwork to the extent required for execution of relevant item under this schedule unless otherwise specified shall be measured and paid under relevant items of Sch 'A' Part-II.
(A) INTERNAL ELECTRIFICATION
Material and labour for point wiring concealed, including rigid non-metallic PVC medium grade conduit ISI marked, 20 mm dia, with FRLS 1.5 Sqmm PVC insulated unsheathed multi stranded copper conductor cable with flush type metal boxes modular type suitable for fixing modular switches sockets fan regulator etc with inner and cover plate and including FRLS PVC insulated unsheathed copper conductor cable of 1.5 sqmm as an earth wire connected to common earth and earth dolly as per IS Specification for one light/fan/bell point controlled by one switch.
All as per item no. 12 here-in-above but for One 3 pin 6 Amp switch socket outlet point on independent board.
All as per item no. 12 here-in-above but for socket outlet 3 pin 16 Amps on independent board with cable size of 2.5 sqmm and earth continuity conductor cable of size 2.5 sqmm.
Supply and fixing surface & wall mounted LED fitting 4' (feet) long with extruded aluminium housing and robust construction 18W to 20W, system lumen (NOM) not less than 1800, complete with electronic driver, suitable for 180 to 240volts AC inputs, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed.
Supply and fixing surface & wall mounted LED fitting with extruded aluminium housing and robust construction 5/6W, system lumen (NOM) not less than 380, complete with electronic driver, suitable for 180 to 240volts AC inputs, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed.
Supply and fixing surface & wall mounted LED fitting with extruded aluminium housing and robust construction 9/10W, system lumen (NOM) not less than 900, complete with electronic driver, suitable for 180 to 240volts AC inputs, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed .
Supply and fixing LED wall light 9 to 12W round/square shaped, suitable for mounting on surface of wall/ceiling with ABS plastic housing and white finish with white powder coat finish, milky white diffuser including complete with electronic driver, suitable for 180 to 240volts AC inputs, system lumen (NOM) not less than 1000, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed.
Supply and fixing LED wall light 18 to 20W round/square shaped, suitable for mounting on surface of wall/ceiling with ABS plastic housing and white finish with white powder coat finish, milky white diffuser including complete with electronic driver, suitable for 180 to 240volts AC inputs, system lumen (NOM) not less than 1580, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements with all accessories all as specified and directed.
Supply and fixing building security LED light 25W aesthetically designed IP65 protection complied to IEC 60598 and IS 10322, system lumen (NOM) not less than 2500, high power LED cool day white, with integral driver, pressure die cast aluminium body including reduced glare, impact resistance, polycarbonate cover complete with suitable for 180 to 240volts AC inputs, Color Temperature is not less than 6000K, THD less than 10%, PF greater than 0.90, CRI greater than 80, not less than IP 2X protection, overall efficiency should be more than 90%, protection from open loop, short circuit, surge protection not less than 2.0 kV and prewired with copper wire complete with hanging/fixing arrangements like street light bracket made out of GI pipe 32mm dia medium grade, 2 sets of clamps nut bolts, washer etc complete with all accessories all as specified and directed.
Supply and Fixing of Ceiling fan efficient 5 star rating 1200 mm sweep 240 V, and connecting up complete including provision of flexible cord 3 core multi stranded copper conductor of size minimum 1.0 sqmm from connector block to fan including connection to earthing point and connecting to complete all as specified and directed.
Supply and Fixing of Exhaust fan with louver shutter 300mm sweep 900RPM, Single phase 240 Volts, 50 Hz complete with all acessories internally pre-wired and including necessary opening on wall for fixing of exhaust fan and make a connection from ceiling rose with 3 core 1.0 sqmm PVC insulated copper conductor cable to connect Exhaust Fan to ceiling rose including making hole, grouting bolts finishing etc. complete all as specified and directed.
Supply and Fixing sheet metal enclosure for DBs suitable for incoming as SPN and outgoing as MCB SP Double door IP43 protection 240volts with bus bar 4 way complete all as specified and directed.
Supply and Fixing sheet metal enclosure for DBs when MCBs to be used SPN Double door IP43 protection 240volts with bus bar 6 way complete all as specified and directed.
Supply and Fixing sheet metal enclosure for vertical type DB for incorporating MCBs , MCCB 4 pole, 8way IP 43 with metal double door with 200Amps rated bus bar 415volts including MCCB/MCB of capacity 63 Amps, 16 KA(TPN) as a incomers complete all as specified and directed.
Supply and fixing MCB SPN 6 to 32 Amps breaking capacity 10 KA C series single phase 240 volts including making connection complete all as specified and as directed.
Supply and fixing MCB SP 6 to 32 Amps breaking capacity 10 KA C series single phase 240 volts including making connection complete all as specified and as directed.
M&L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC-FRLS insulated and unsheathed multi stranded copper conductor cable LT 1100 V grade drawn in and PVC conduit of size 20 mm dia concealed in wall with all necessary fittings and accessories and run of FRLS insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through PVC conduit and connected to common earth dolly ,complete all as specified and directed. Note :- (i)Two run of cable and one run of PVC conduit and one run of earth continuity wire for connections to DBs/dolly shall be deemed to be included in this item and shall be as one run complete all as specified and directed. (ii) Strictly follow the proper colour code as a red, yellow, blue for phase, black for neutral and green for earth.
M&L for sub main wiring with 4.0 single core PVC FRLS insulated unsheathed stranded copper conductor cable of size 4 Sqmm drawn in including rigid non metallic PVC conduit ISI marked not less than 25mm dia all fitting such as Tee,bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock , nuts, saddlers , pipe hooks etc fixed properly on as in concealed position on wall and surface position on ceiling/Roof/Trusses including cutting chasing and making good to disturbed surfaces and matching with the existing colour of wall/floor etc two runs of 4 Sqmm PVC FRLS insulated unsheathed stranded copper conductor as a continous earth wire complete all as specified and directed. Note:- (i) Four runs of cable and one run of PVC conduit and two runs earth continuity wires for connection to DB's/Dolly shall be deemed to be included in this item and shall be as one run complete all as specified. (ii) Strictly follow the proper colour code as a red, yellow, blue for phase, black for neutral and green for earth.
M&L for sub main wiring with 6.0 single core PVC FRLS insulated unsheathed stranded copper conductor cable of size 6 Sqmm drawn in including rigid non metallic PVC conduit ISI marked not less than 32mm dia all fitting such as Tee,bends, reducer, elbow, bell mouth, tube ends and all fixing accessories such as couplers lock , nuts, saddlers , pipe hooks etc fixed properly on as in concealed position on wall and surface position on ceiling/Roof/Trusses including cutting chasing and making good to disturbed surfaces and matching with the existing colour of wall/floor etc two runs of 6 Sqmm PVC FRLS insulated unsheathed stranded copper conductor as a continous earth wire complete all as specified and directed. Note:- (i) Four runs of cable and one run of PVC conduit and two runs earth continuity wires for connection to DB's/Dolly shall be deemed to be included in this item and shall be as one run complete all as specified. (ii) Strictly follow the proper colour code as a red, yellow, blue for phase, black for neutral and green for earth.
M&L for Earthing complete with Galvanised steel earth plate electrode of size 600 mm x 600 mm x 6mm thick, buried directly to ground (vertically to a depth not less than 2.25 metres below the ground level) with top edge of earth plate not less than 1.5 metres below normal ground level, connected to Galvanised iron wire of 4.00 mm diametre earth lead by means of bolts, nuts, washer and check nut of galvanised steel earth wire protected by and including GI pipe 15mm bore (medium grade) and connected to main switch/ MCB DBs box point as directed and including cement concrete pit with CI cover 10mm thick hinged to CI frame all as shown under electrical plate no 3 SSR part I 2009 including painting the external surface of chamber & cover with enamel paint in different colour as directed and wiremesh funnel, 20mm bore GI pipe (medium grade)for watering, charcoal and salt in alternative layers of 15cm thick all around the electrode (90cmx90cm) including necessary excavation and earth work in any type of soil complete all as shown in electrical plate of SSR part - I and testing on completion all as specified and directed.
supply and fix shadow less light fitting complete with power unit & battery back up for min 30 minutes (maximum 5 KVA) having dome of not less than 500 mm dia, fully counter balanced and fixed on suspension rod, capable of having axial rotation of 360 deg. The unit to be suitable for minor OT and Capable for operation on 230 V single phase 50 cycles mains supply having Lux level > 1,20,000 lux light head dia maximum 67cm. Technical specifications (a) Make : (i)Meditech(INDIA)- Model No: Z 400 + 300 (ii) STAR LED 5 NX- Model No. EN 60601-2-41 (iii) Dr, Med LED - Model No. LED, 70 single Dome LED (b) No of Dome : 1 No (c) Input Supply voltage : 110V-230V AC + 10%. (d) Diameter of Dome : not less than 500mm. (e) Rated life of LED : >50,000 hours. (f) Light outlet : >1,20,000 Lux (g) Illumination depth : >140 cm. (h) Working distance : 50 – 180 cm. (j) Color Temperature : 4300 + 5000K. (k) CRI : 95. (l) Red Color Index : 97. (m) Ceiling & Arm rotation : 3600. (n) Intensity Control : By Control Panel. (o) Focusing : By Serializable Handle. (p) Multi position Spring Arm for comfortable Surgery. (q) CE Certified (IEC 60601/1/2/41, EN 1041/980, EN ISO9001:2008, EN ISO 14971).
Supply & fix MCB protected modular socket (Modular AC Box) 25 Amps, heavy duty 230V, AC complete all as specified and directed.
Supply & fix 25 Amps modular motor starter switches 230V AC complete all as specified and directed.
(C) EXTERNAL WATER SUPPLY
M&L for fitting for DI socket/spigot socketed pipe upto 150mm bore as bends (any type radius and angle) tapers any type (straight, bend increasing, decreasing or double socket etc) tea pieces single branch Y junction, double branch cross (all sockets or socket and spigot ) collar cap and plug complete all as specified and directed.
M&L for construction of brick masonry valve pit chamber including necessary excavation and earth work and MS sheet cover 3mm thick and angle iron 40x40x6mm frame incluidng locking arrangements with 50mm pad lock and duplicate keys, duly painting the steel surfaces in two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified for size 600x600x600mm (Internal dimension).
(D) EXTERNAL ELECTRIC SUPPLY
M& L for boring through existing road for passing of UG cable all as specified and directed.
Supply ,installation, testing and commissioning of vaccum circuit breaker (VCB) indoor type, HT 11KV, 3 Phase, 50 Hz floor mounted standalone totally enclosed metal clad switchgear horizontal isolation and horizontal drawing out type with rupturing capacity of 350 MVA, 630A capacity having protection of IP4X conforming to IS13118, motor charged independent spring closing/tripping, trip free operating mechanism with normal closing and tripping push button and spring charge / discharge indication and including the following:-
Supply ,installation , testing and commissioning (outdoor type) platform mounted step down transformer of capacity 100 KVA, 11KV/415 Volts (at no load),AC 3 phase, 50 Hz of following capacity core type copper wound, oil immersed, oil natural- Air natural (ONAN) with external cooling tube, delta connection on primary side (HV) and star connected on secondary side (LV) in accordance with vector group DYN- 11 with neutral brought out on secondary side (LV side) and having off load tapping's at 4 Nos with steps of 2.5% from + 2.5% to (-) 5% and confirm to IS 1180 part-I: 2014 level 3/ IS 2026 ISI mark and Star rate BEE on HV side to be changed by means of hand operated OFF load tap changer gear . The maximum temprature rise should not exceed 30 degree celsius in oil and 40 degree celsius in HV/LV winding when measured by resistance method after continuous full load run on and ambient temprature of 40 degree celsius. Transformer shall comprises of the following:-
(a)One cable HT end box (Primary side) consisting of three Nos. porcelain bushings complete with nut & washers complete. (b) One cable box LT side (secondary side) consisting of four Nos porcelain bushing complete with nut & washers with one No cable gland, material etc complete. (c) Oil conservator with filter type drain valve and of level gauge complete. (d) De-hydrating breather with first fill of dehydrating agent (Silica gel). (e) Explosive vent & thermometer pocket on tank cover, oil level gauge, oil drain filter valve, lifting lugs, oil filling hole with cap/plug with connection plate complete, Air relase vlave plug and four Nos solid cast steel detachable rollers (f) One 100mm dia, dial type thermometer, vapour pressure type having range 0-120 degree celsius with metal guard having maximum perimeter temprature reading indicator with re-setting device (g) Two earthing terminals to facillitate fixing of 50x6mm galvanised iron earth strip for earthing of neutral & body. (h) Rating plate and terminal marking plate (j) Extra bushing for neutral in the LT cable box for providing independent set of earthing for neutral. (k) first filling of new and unused transformer oil confirm to IS-335 marked filtered and tested as per IS-335 air gap between testing electrodes. Note: Cost of construction of PCC platform (of size 1.5mx1.5m and height 0.9m above the GL) with brick work in CM (1:6), 15mm thick plaster in CM (1:6) & white wash on exposed surface and 150 mm thick PCC flooring (1:3:6) type CI over 100mm PCC 1:5:10 over filling with approved earth in layers n. exc 25 cm thick and 02 Nos MS Channels of requisite size with fixing arrangement for mounting transformer shall be deemed to be included in the unit rate quoted for above item.
M&L for earthing complete with copper earth plate electrode 600×600×3 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to copper earth lead strip of 32x6 mm by means of bolts, nuts, check nuts and washers of brass complete all connected to earthing test point complete all as specified or indicated including testing on completion including necessary excavation, earthwork returning filling, remove) of extra soil etc, filling adequate qty of charcoal dust, common salt,PCC work in (1:3:6) type C-1 (using 20mm graded stone aggregate) cover slab 40mm thick reinforced with 8mm dia TMT bars @ 75mm C/C both way with two no's lifting handle, GI pipe 20mm dia medium grade with funnel & wire mesh for watering and 40mm dia GI pipe tubing medium grade for earth strip protection complete all as spedified and directed.
Supply & fixing street light fittings LED type 72 Watts complete with LED dirvers etc. Inculding street light bracket made out of GI pipe medium grade 25mm outer dia, 0.80m long bent to shape fixed with 2 sets of clamps , nuts, bolts, washers, etc. for LED light and making the connection of LED light to junction box with copper conducting wire complete all as specified and directed. Make: C&S Product code INDUS/90W/LS or equivalent.
Supply & fixing steel tubular swaged poles 9.0 metres long (straight) type 410 SP-31 complete with CI base plate nuts, bolts top cover and screws making two nos holes on pole for cable protection inside of pole for connection including PCC foundation in (1:4:8) type C-2 using 40mm graded stone aggregate and PCC 1:3:6 type B-1 using 20mm graded stone aggregate as in coping for poles including necessary formwork(straight curve) and finishing to all exposed surfaces of concrete including necessary earth work and excavation including applying two coat of aluminium paint over a coat of red oxide primer on pole and painting 03Nos band/strip with fluorscent sky blue synthetic enamel paint (30 cm wide each at distance of 30 cm from plinth block including writing numbers with white paint above 1.5 mtr above ground level over black painted surfaces complete all as specified and directed.
Supply and fixing stylish,robust and reliable post top lantern using LEDs, 43 Watt having good light distribution, limited upward light component that avoid light pollution complete with all suitable size GI pipe (medium grade) of required length alongwith all accessories and making connection all as specified and directed. Make philips product code BGP151 LED300/NW PSU 220-240V 7043 or equivalent.
S&F junction box of size 200mm x 140mm x 95mm readymade polycarbonate made out of pilferage proof with 200 amp aluminium bus bar fixed on SMC/DMC insulator and pole box fixed on pole by suitable clamp with nut, washers and made incoming and outgoing connection, complete all as specified and directed. Make : Model - GSJB-2014 of sintex or equivalent
M&L for floor mounted LT panel board outdoor type factory made and tested (CPRI approved) 415 volts 3 phase 4 wire 50 Hz AC supply having busbar chamber 200 Amps Aluminium strip 4 Nos., installed on SMC/DMC insulators, and copper conductor wiring, the panel shall be dust and vermin proof and made up of 3.15mm CRCA mild steel sheet and 40x40x6mm thick angle iron frame work, power coated finish over one coat of red oxide of primer outside and inside, front and rear opening type, with aprons for cable entry with double door shutter and locking arrangement, internal wiring with PVC insulated solid copper conductor FRLS cables, IS-694 marked of adequate size but not less than 4Sqmm and suitable to accomodate and including the following accessories:-
Supply ,installation , testing and commissioning of silent, diesel engine driven factory assembled floor mounted generating set of capacity 62.5 KVA, 3phase, 4 wire 50 Hz, 1500 RPM as per IS 10001/10002 complete with safety control and metering equipment mounted on and inducing common base frame on new PCC foundation as recmmended by manufacurer all as specified and comprising the following:-
(a) Prime mover:- Directly coupled diesel engine, water cooled suitably de-ratea of matching BHP for driving 62.5 KVA capacity, alternator electric start, four stroke confirming to Iciest IS-10001/10002 for continuous running and capable for taking 10 percent overload for 10 hours complete with following accessories:- (i) Fly wheel to suit flexible coupling (ii) Flexible coupling with guards (iii) Air cleaner with fillers (iv) Lubricating oil filters (v) Anti vibrating pad as recommended by manufacturers. (vi) PT pump with electronic governor of suitable capacity. (vii) Self starter 12 volt DC (viii) Necessary arrangement for charging battery. (ix) Lead acid storage battery 12 volt - 01No as recommend by manufactrurer alongwith flexible copper battery lead and connector (x) Battery rack made out of MS angle iron 40mmx40mm x5mm and 150mm height -01No (xi) Standard safety device (xii) Daily services fuel tank for full running capacity of DG set for minimum 08 hrs enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain plug, air vent and locking arrangenment etc. including fuel pipe connections from fuel tank to DG set and overflow form DG set to fuel tank complete with gate valve. (xiii) Exhaust system shall be provided with thermal insulation by using fire retardant/non igniting foam conforming to BS 4735 to prevent excess heat radiation on the engine and safe for operator (xiv) Mechanical panel having following accessories:-
(aa) Lubrication oil pressure gauge - 01 No (ab) water temprature gauge-01No (ac)Starting switch with key - 01No (ad)Battery voltmeter (ae) Indicator lamp etc. (af) Safety measures. (i) Low lubricant oil pressure trip. (ii) High coolant temprature trip. (iii) Engine over speed trip. (iv) Battery charging alternator. (v) Emergency stop pressed.
(B)ALTERNATOR:- 62.5 KVA at 0.8 power factor, self regulated 3 phase with neutral 415volts 50Hz 1500RPM as per IS: 13364 complete with automatic voltage regulator and foot mounted including making cable connection. The salient feature of alternator are as under:- (i)Voltage regulation under static condition + 1.5% (ii)Class 'H' insulation (iii) Permanently lubricating bearing (iv) Capable to take 10% overload for 30 min for every 12 hours Control AMF Panel:- AMF control panel factory made cubical type floor mounted totally enclosed fabricated out CRCA sheet 14 SWG over on angle iron frame made out of 50x50x6mm angle with removable side cover hinged front panel and rear panel for easy accessibility epoxy powder coated complete with internal wiring with suitable size copper conductor cable and cable gland for external connection complete suitable for 62.5 KVA DG set with by pass assesment including all necessary operating and control device (to meet the rquirement of above capacity plus 25% over load ) such as contactors MCCB's, CT's voltmeter, Ammeter,Indicating lamp, frequency meter, energy meter with protection fuses for panel instrument battery charging system with indicator and cut off relays low and high oil pressure, high speed overload and earth fault protection, reverse current protection duly wired with flexible copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufacturers and as directed.
(c) Tool kit to be supplied with DG set are as under :- (i) Ring spanner set of 10 - 1set (ii) Screw driver 6"x8" and 12"x14" - 01No each (iii) Adjustable spanner 12" - 01No (iv) Double end spanner set 10 - 01No (v) Cutting pliers 10" - 01No (vi) Tool box -01No (D) Acoustic enclousers:- floor mounted acoustic enclosures suitable for 62.5KVA DG set as per CPCB norms of the make as that of DG set be provided.
AIR CONDITIONING
S&F wall mounted Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of + 2.5% and of capacity 5.0 KVA complete all as specified and directed. Note: Item should be under one year gurantee period and any defect in the item should be rectified by the contractor without any cost.
FIRE DETECTION AND ALARM SYSTEM
Supply , installation, testing and commissioning of intelligent addressable isolator module, automatic device mapping, electronic addressing, ground fault detection by address, mimic panel Self-restoring . Make : Edwards Cat No ( SIGA-IM) all as specified and directed as in standard schedule of rates-2009 Part-1 Specification, Para 27.5.1
Supply and fix 2X 1.5 sqmm copper PVC FRLS cable (in meters) including clamping on wall passing through pipe etc. all as specified and directed.
GAS MANIFOLD SYSTEM
Supply installation, tasting and commissioning of 6 + 6 oxygen manifold system extendable type with 12 Nos non return valves (without cylinder) to an uninterrupted supply during change over complete all as specified and directed.
Supply installation, testing and commissioning of 1 + 1 emergency manifold for oxygen supply with Double Stage ISI Marked. Make- ESAB regulator & NRV
Supply, installation, testing of flexible tail pipe to connect cylinder with manifold NRV made of Taflon tube breaded with stainless steel Wire and covered by S.S Spring complete all as specified and directed.
S&F back pressure compensated flow meter with flow range 0-15 ltr/m, high quality brass body with unbreakable humidifier bottle complete all as specified and directed.
Supply, installation, testing and commissioning of fully automatic control panel CE marked digital display type to indicate just before manifold switches from bank in use to reserve without fluctutation in delievery line pressure the panel shall be fitted with standby regulators besides line I regulator and the control panel with three coloured LEDs complete all as specified and directed.
Supply, installation, testing and commissioning of probe adaptor for outlet point terminal unit complete all as specified and directed.
M&L for central vacuum system with vacuum pump model V 255 5 HP electrical motor V-belt drive, vacuum reservoir of 1200 ltrs, 1 No non- return valve and on line bacterial filter complete all as specified and directed.
Supply, installation, testing and commissioning of bed head panel for ICU 4ft size. The bed head panel made of high strength extruded aluminium profile with powder coating with choice of colour to suit the interior décor of the hospital complete all as specified & directed. Each bed head panel shall be provided with the following:- (i) oxygen outlet point-02 Nos. (ii) suction outlet point - 02 Nos. (iii) 5/15 amps electrical socket 03 Nos. aluminium railing to accommodate IV stand ward vaccum unit and infusion pump stand complete all as specified & directed.
Supply, installation, testing and commissioning of mobile floor suction unit for operation theatre made of stainless steel having one vaccum regulator and suction jar of 1000ml capacity complete all as specified and directed.
Supply, installation & testing of isolation valve 12mm size complete with brass connectors all as specified and directed.
Supply, installation & testing of isolation valve 15mm size complete with brass connectors all as specified and directed.
Supply, installation & testing isolation valve 22 mm size complete with brass connector all as specified and directed.
Supply, installation & testing isolation valve 28 mm size complete with brass connectors all as specified and directed.
Supply, installation & testing isolation valve 42 mm size complete with brass connectors all as specified and directed.
Supply, installation, testing and commissioning of copper pipe, seamless, deoxidized, non arsenical, half hard, tempered and degrees manufatured as per BS 2871 Pt. I table-X of 1971 chemical composition as per BS 6017 of 1981 table 2, Gu-DHP complete all as specified & directed.
(a) 12 mm dia OD X 0.7 mm thick
(b) 15 mm dia OD X 0.9 mm thick
(c) 22 mm dia OD X 0.9 mm thick
(d) 28 mm dia x 0.9 mm thick
(e) 42 mm x 1.2 mm thick
Supply, installation and testing of electric control panel with cascading and duple xing for vaccum pump and compressor complete all as specified and directed.
Supply, installations testing and commissioning of area alarm system pneumatically four channel micro processor control alarm for two gases and vaccum services with digital display of line pressure for all the services with factory calibrated pressure sensors. colour coded LED % I display of line pressure status (high-> caution->normal->caution->low). it has audible alarm for high & low pressure condition for facility of alarm limit for all four gases operates on 230 volt AC supply complete all as specified & directed.
Supply, installations testing and commissioning of zonal valve boxes with lockable box & front covered with glass for two gases complete all as specified & directed.
Supply, installations testing and commencing of 4” dial pressure gauge for oxygen & suction line complete all as specified & directed.
supply, installations testing and commissioning for low pressure tube (transparent)for suction units complete all as specified and directed.
M& L for Stainless steel clamps to hold suction assembly complete all as specified and directed Note: Monthly/yearly maintenance and monthly serviceability test to be carried out by equipment installed system contractor after installation and commissioning of the complete system.
PROVISION OF LIFT
supply and fix lift electrically operated 415 Volts, 3 Phase AC Microprocessor controlled complete with power driven automatic stainless steel (SS) sliding doors and having SS car enclosure of size 1000x2400 mm, suitable for hospital stretcher, suitable to carry 15 passangers (1020 kgs) at a speed of 0.5 Mtr/sec to serve upto 02 floor (G+1) including automatic rescue device and have a rise of 4 mtr and traction media flat coated steel belt, car finish should be of SS for rear mid panel, rear corner panel, side mid panel, side corner panel, front panel, false ceilling finish should be SS finish, type CD 41 and including the overload device, emergency fire man service emergency car light unit, infrared curtain door protection, doortime protection emergency alarm button, door open and close button, manual rescue operation, belt inspection drive, autofan cutoff etc. The description of lift is as below (a) Number of stops: 2 stop with all opening on the same size (b)Machine specification: TM Genrless (located in shafton top of guide rails (c) Ventilation: Cross flow fan
(d) Flooring: Granamite (20 mm recess be provided) (e) Car door finish: Stainless steel (Hairline) (f) Landing door finish: Stainless steel (Hairline) (g)Fire rating : 120 min (h) Pit depth 1350 (j) Overhead: 4000 (k) Hoist way dimensions: 1900mm W x 2750mm D (l) Car dimensions : 1000mm W x2400mm D x2200mm H (m) Car and Hoist way door type : Telescopic 2 speed door (n)Door Opening :900mm W X 2750mm D (o)Door operator: DC Door Operator (p) Car Position Indicator: dot matrix (led)scrolling display (q)Hall fixture/hall fixture fare plate:Pan type fixture/stainless steel (Hairline) (r)Standard features : Anti-nusiance car call protection, Independent service (for duplex only),Overload device,Nudging,Emergency firemen,s service Emergency car light unit, Infrared curtain door protection, Door time protection, Emergency alarm button, Extra door time of lobby & parking,Door open/close button,Manual rescue operation,Belt inspection device,auto fan cut off. (s)Option included: Automatic restore operation complete all as specified and directed.
COMPREHENSIVE MAINTENANCE & OPERATION OF LIFT
(i) Qualification of the operator must obtain ITI certificate of particular field or five years of experience in operation of lift. (ii) Attendance in Biometric attendance system shall be marked twice during the duty hrs. Firstly at the start of duty hrs and secondly at the completion of duty hrs before leaving the assigned duty place. (iii) Payment to the contractor shall be issued as per attendance of workmen, registered in the designated biometric attendance machine. (iv) Monthly printout of attendance, duly verified by contractor and Engineer-in-Charge, shall be kept in record for payment purpose. (v) Contractor shall regularly monitor and verify the attendance being market in the biomentric attendance machine and bring any absence or change of workmen to the notice of Engr-in-Charge in writing immediately. (vi) Employment of workmen and payment thereof shall be regulated by EPF & MP Act 1952 as amended time to time by GOI. (vii) PAYMENT OF WORKERS :- Contractor shall arrange to open bank account in any Nationalised Bank of all labour/workers employed for execution of work and wages paid to workers through bank transation i.e. NEFT, cheque etc. The proof of the same shall be produced to the Engr-in-Charge for verification. (viii) UNIFORM/CLOTHING :- The duty staff/operator should be in proper uniform, uniform to be provided by contractor after getting approval of GE/EIC . (ix) Contractor will carryout routine maintenance of the lift as per the manufacturer norms or instructions give by GE/Eng-in-Chrge. (x) Penalty :- If the operator found absent from the duty double the amount of the pay shall be recovered from the work done. (xi) Minimum wages :- While dropping the tender for the subject work it is advised to the contractor that the minimum wages for the technicians must not be lower than the Govt rates under the minimum wages act-1948 IX Vol). As per the directions of the HQ CE (AF) Nagpur, contractors must not be quote below the prescribed rates issued by the Govt if so they will be disqualify for the bid automatically). (xii) Any minor/major repair/replacement in the plant/lift if required will be carried out by the contractor without any extra payment within the defect liability period and after defect liability period will be carried out under the AMC.
MAINTENANCE AND OPERATIONS FOR FIRST YEAR :- Providing services for OEM trained techanician for round 'o' clock duties (03 shift in a day by deploying one trained technician in a each shift including Sunday and holiday) for lift for attending/monitoring the breakdown and preventive maintenance of entire system installed under above schedule during first year of defect liability period. The technician shall be competent in following field:- (a) Trouble shooting, repairs and maintenance of lift control pannels. (b) Uploading and downloadig of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as cabin, doors control panel, drives, pulley, chain,gears system, electric motor, sensors etc. and maintain proper log sheets of the work carried out. Note :- (i) Contractor shall provide required T&P for technician so employed. (ii) Manpower so provided shall also be responsible for operation of lift. (iii) The contractor shall enter a MOU with OEMs for the provision of the lift and further maintenance. The MOU for the post warranty/post defect liability period between the contractor and OEM shall be submitted at least six months prior to the issue of completion certificate of the main contract. (iv) Contractor shall provide mobile to operator for communication.
MAINTENANCE AND OPERATIONS FOR SECOND YEAR :- Providing services for OEM trained techanician for round 'o' clock duties (03 shift in a day by deploying one trained techanician in a each shift including Sunday and holiday) for lift for attending/monitoring the breakdown and preventive maintenance of entire system installed under above schedule during first year of defect liability period. The technician shall be competent in following field :- (a) Trouble shooting, repairs and maintenance of lift control panels. (b) Uploading and downloadig of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be resposible for all short of periodical servicing required for the system like as cabin, doors control panel, drives, pulley, chain,gears system, electric motor, sensonrs etc. and maintain proper log sheets of the work carried out. Note :- (i) Contractor shall provide required T&P for technician so employed. (ii) Manpower so provided shall also be responsible for operation of lift. (iii) The contractor shall enter a MOU with the OEMs for the provision of the lift and further maintenance. THe MOU for the post warranty/post defect liabilty period between the contractor and OEM shall be submitted at least six months prior to the issue of completion certificate of the main contract. (iv) Contractor shall provide mobile to operator for communication.
MAINTENANCE AND OPEARATIONS AND AMC FOR THIRD YEAR (AFTER DEFECT LIABILITY PERIOD):- Annual comprehensive maintenance and outsourcing for monitoring management and operations of lift system installed under Sch 'A' Part -I i.e. upto 12 months from actual date of completion of defect liability period including all necessary spares for lift. It includes providing the following manpower :- Three company trained technician (ITI holder in mechanical/lift operation) (OEM based lift system) for attending/monitoring the breakdown and preventive maintanence in the three shifts including sunday and holiday (One technician in each shift). The trained technician shall possess a certificate from the lift manufacturer clearly stating that he/she has been trained in :- (a) Trouble shooting, repairs and maintenance of lift control panels. (b) Uploading and downloadig of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as LT control panels, electric motor, sensors etc and maintain proper log sheets of the work carried out. Note :- (i) Contractor shall provide provide required T&P for technician so employed. (ii) Manpower so provided shall also be responsible for operatin of lift. (iii) All spares required for smooth and efficient working of the system. The technician shall carry out the above preventive maintenance and maintain proper log sheet. (iv) Contractor shall provide mobile to operator for communication.
MAINTENANCE AND OPERATIONS AND AMC FOR FOURTH YEAR (AFTER ONE YEAR OR DEFECT LIABILITY PERIOD) :- Annual comprehensive maintenance and outsourcing for monitoring management and operation of lift system insatalled under Sch 'A' Part - I i.e. upto 12 months from one year of completion of defect liability period including all necessary spares for lift. It includes providing the following manpower : Three company trained technician (ITI holder in mechanical/lift operation) (OEM based lift system) for attending/monitoring the breakdown and preventive maintenance in the three shifts including sunday and holiday (One technician in each shift). The trained technician shall pssess a certificate from the lift manufacturer clearly stating that he/she has been trained in :- (a) Trouble shooting, repairs and maintenance of lift control panels. (b) Uploading and downloadig of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Technician shall be responsible for all short of periodical servicing required for the system like as LT control panels, electric motor,sensors etc. and maintain proper log sheets of the work carried out. Note :- (i) Contractor shall provide required T&P for technician so employed. (ii) Manpower so provided shall also be responsible for operation of lift. (iii) All spares required for smooth and efficient working of the system. The technician shall carry out the above preventive maintenance and maintain proper log sheet. (iv) Contractor shall provide mobile to operator for communication.
MAINTENANCE AND OPERATIONS AND AMC FOR FIFTH YEAR (AFTER TWO YEARS OF DEFECT LIABILITY PERIOD):- Annual comprehensive maintenance and outsourcing for monitoring management and operation of lift system installed under Sch 'A' Part -I i.e upto 12 months from two years of completion of defect liability period inluding all necessary spares for lift. It includes providing the following manpower :- Three company trained technician (ITI holder in mechanical/lift operator) (OEM based lift system) for attending/montoring the breakdown and preventive maintenace in the three shifts including sunday and holiday (One technician in each shift). The trained technician shall possess a certificate from the lift manufacturer clearly stating that he/she has been trained in :- (a) Trouble shooting, repairs and maintenance of lift control panels. (b) Uploading and downloadig of ladder logic based programs. (c) Manual/Remote operation of lift and act as assistant for rescue in case of any failure of lift. (d) Tecnician shall be responsible for all short of periodical servicing required for the system like as LT control panels, electric motor, sensors etc. and maintain proper log sheets of the work carried out. Note :- (i) Contractor shall provide required T&P for technicia so employed. (ii) Manpower so provided shall also be responsible for operation of lift. (iii) All spares required for smooth and efficient working of the system. The technician shall carry out the above preventive maintenance and maintain proper log sheet. (iv) Contractor shall provide mobile to operator for communication.
Note: The amount against Schedule of Credit on Page No. 58 shall be deducted from the total amount quoted against Sch 'A' while deriving the Contract Sum for Acceptance.
B.K.ASSOCIATES
MD BUILDER
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .