Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance GROUND FLOOR 72 BUSINESS PARK CROSS ROAD C MAROL INDUSTRIAL AREA MIDC ANDHERI EAST MUMBAI MUMBAI MAHARASHTRA 400093 | MUMBAI SUBURBAN | MAHARASHTRA | 400093 | Admitted-Finance |
| 2 | Admitted-Finance 49 2 BANGUR AVENUE BLOCK C KOLKATA 700055 | KOLKATA | KOLKATA | WEST BENGAL | 700055 | Admitted-Finance |
| 3 | Admitted-Finance GF 22 GROUND FLOOR OMAXE SQUARE JASOLA DISTRICT CENTRE NEW DELHI SOUTH DELHI DELHI 110025 | SOUTH EAST DELHI | DELHI | 110025 | Admitted-Finance |
| 4 | Admitted-Finance B 10 KRISHNA INDUSTRIAL ESTATE OPP B I D C GORWA ESTATE VADODARA 390016 GUJARAT | VADODARA | GUJARAT | 390016 | Admitted-Finance |
| 5 | Admitted-Finance SHOP NO 2 KAMOTHE ANIRRUDHA HEIGHT KAMOTHE PLOT NO 168 VILLAGE TOWN SECTOR 34 CITY NAVI MUMBAI RAIGAD MAHARASHTRA 410209 INDIA | RAIGAD | MAHARASHTRA | 410209 | Admitted-Finance |
Tender Value
₹47.2 L
EMD Value
₹94,440
Closing Date
16 Oct 2024, 3:00 pmClosed
Chief Executive BRIT
BRIT Opp APMC Gate no.2, Sector 20, Vashi, Navi Mumbai-400703
Geotechnical Investigation for proposed under EIPS building at BRIT Vashi Complex, Navi Mumbai
2024_BRIT_825611_1
BRIT/ES/CIVIL PH/2024-2025/08 Dated 06/09/2024
Open Tender
Civil Works
Item Rate
270 days
BARC/BRIT Vashi Complex
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹94,440
BARC/BRIT Vashi Complex, Sec 20, Vashi
21 Jan 2025
17 Sept 2024
18 Oct 2024
17 Sept 2024
16 Oct 2024
3 Oct 2024
17 Sept 2024 - 24 Sept 2024
27 Sept 2024
Amount
(I) Field Tests on Rock/ Soils 'Clearing Jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings and removal of rubbish up to a distance of 50 m / outside the periphery of the area cleared as per specifications to facilitate geotechnical investigation and as directed by the Engineer-in-charge. (Note : Area required for investigation alone to be cleared and will be measured for payment)
Mobilisation and demobilisation of suitable boring plant and all other allied equipments like Minimum 2 boring rigs or as required number of boring rigs to complete the job in time, survey equipments and all other insitu tests equipments and manpower required to complete the scope of this work.
Setting up of boring rig at each location, only once for each borehole location including moves between borehole position greater than 5 M locating and marking the location on the ground by actual survey, setting up all field test equipments and bringing all personal to the location, making area good for setting up rig etc. complete.
Boring vertically through all kinds of soils, weathered rock and soft rock, boulders, if any met during drilling with suitable and adequate equipment as required for the depth as measured below existing ground level. 'Notes:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4) Bore holes, location, depth as specified in the drawing no. A&SED/ST/4011/00/TD/A1-001/R-A sheet 1 of 1 or as specified by Engineer incharge. '0 m to 10 m. From G.L
Boring vertically through all kinds of soils, weathered rock and soft rock, boulders, if any met during drilling with suitable and adequate equipment as required for the depth as measured below existing ground level. 'Notes:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4) Bore holes, location, depth as specified in the drawing no. A&SED/ST/4011/00/TD/A1-001/R-A sheet 1 of 1 or as specified by Engineer incharge. '10 m to 20 m. From G.L
Boring vertically through all kinds of soils, weathered rock and soft rock, boulders, if any met during drilling with suitable and adequate equipment as required for the depth as measured below existing ground level. 'Notes:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4) Bore holes, location, depth as specified in the drawing no. A&SED/ST/4011/00/TD/A1-001/R-A sheet 1 of 1 or as specified by Engineer incharge. '20 m to 30 m. From G.L
Drilling vertically through bedrock strata (Hard rock), using Nx size diamond bit, using double tube core barrel with suitable core catcher, including collection and logging of cores, placing them in approved wooden core boxes made up of 25mm thick planks with partitions of 12mm thick as per relevant IS with a coat of Anti Termite chemical in a proper sequence, numbering each core, noting the lithology, colour photographs (100X150mm size) of rock cores, locking arrangements, labeling and transporting the boxes to core store/laboratory as directed by EIC etc., all as per specifications for the following depths measured from existing ground level : 'Notes:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4)Bore holes, location, depth as specified in the drawing no. A&SED/ST/4011/00/TD/A1-001/R-A sheet 1 of 1 or as specified by Engineer incharge. '0 m to 20 m. From G.L
Drilling vertically through bedrock strata (Hard rock), using Nx size diamond bit, using double tube core barrel with suitable core catcher, including collection and logging of cores, placing them in approved wooden core boxes made up of 25mm thick planks with partitions of 12mm thick as per relevant IS with a coat of Anti Termite chemical in a proper sequence, numbering each core, noting the lithology, colour photographs (100X150mm size) of rock cores, locking arrangements, labeling and transporting the boxes to core store/laboratory as directed by EIC etc., all as per specifications for the following depths measured from existing ground level : 'Notes:(1) RQD of 10% and less will be considered as weathered/soft rock. (2) The soft or weathered rock underlying hard rock with thickness greater than 0.5 M will be considered as soft or weathered rock. (3) Core recovery of 20% and less also considered as soft rock at appropriate depth. 4)Bore holes, location, depth as specified in the drawing no. A&SED/ST/4011/00/TD/A1-001/R-A sheet 1 of 1 or as specified by Engineer incharge. '20 m to 40 m. From G.L
Obtaining 90 mm diameter, 450 mm long undisturbed soil samples (UDS ) from boreholes WITH JARRING LINK in soil, soft and weathered rock and collecting packaging and labeling.
Conducting Standard Penetration Tests (SPT) in soil, soft and weathered rock and collecting, packaging and labelling disturbed soil/rock samples there from all as per IS:2131-1981(reaffirmed in 2002).
Conducting Standard Penetration Tests (SPT) as in Item No. 7 above but with part of the distrubed soil samples of medium stiff to hard cohesive soils to be coated with paraffin wax and sealed immediately on collection to completely retain all moisture within the sample, and part of the sample to be collected, packaged and sealed as in item No. 7 above.
Conducting SPT in rock with RQD greater than 10% and less than 25% all as per specifications, including replacement of SPT shoe by a new SPT shoe for each SPT as per specifications.
Collection of ground water samples for evaluation of ground water level and their variation as per IS:1892-1979(reaffirmed in 2002), IS:6935-1973(reaffirmed in 2012) from each borehole at specified depths (minimum 1 litre) including all provisions of sampling, packing, sealing and labeling as specified and including handling charges etc. all as per specifications.
Conducting cross borehole test comprising of five boreholes, one source and four receiver bore holes (two in X-direction and two in Y-direction) for evaluation of Dynamic modulli ,dynamic Poisson's ratio,shear and compression wave velocity variation with depth . The test shall be conducted as per IS 13372(Part 2):1992 (reaffirmed in 2001),ASTM:D4428,ASTM:D7400 at specified location and depth as per drawing no. A&SED/ST/4011/00/TD/A1-001/R-A sheet 1 of 1 excluding cost of drilling of appropriate size bore holes required for test upto 50 m depth, which will be paid under relevant Item No.4 and 5 of this bill of quantity, PVC/Aluminum pipe casing, grouting and backfilling complete as per specifications and as directed by Engineer-in-charge.
Backfilling of boreholes with 1:1 cement : bentonite/ mud grout as per specification. Operating of this item is must for satisfactory completion of work.
Conducting Plate Load Test ( asper IS: 1888-1982 reaffirmed 2007) at foundation level using 600mm x 600mm test plate including cost of excavation, dewtering, all arrangement for reaction loading, all as per the specifications and as directed by Engineer in Charge. Testing depth level as recommended by Geotech consultant 'At 3.00 Metre depth level
Carrying Electrical resistivity test for evaluating ground water level and its variation along with subsurface stratification,ground profiling by Schlumberger four electrode method including submission of comprehensive report with interpreted results for layer thickness and resistivities in triplicate. The test is to be conducted as per IS:1892 -1979(Reaffirmed in 2002), IS:15736-2007(Reaffirmed in 2012) covering whole plan area of building upto depth of exploration as specified & recommended by Engineer in charge below existing ground level.
Carrying out Core cutter method (CCM) test (for fine grained cohesive soils) as per IS:2720(Part XXIX)-1975 (Reaffirmed 2005) to evaluate Bulkdensity,dry density.The test is to be conducted on one or more UDS(undisturbed sample) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC.
Carrying out Sand replacement method test (for medium&coarse grained soil) as per IS:2720(Part XXVIII)-1974 (Reaffirmed 2010) to evaluate Bulkdensity,dry density.The test is to be conducted on one or more DS(disturbed sample )collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC.
Static Cone Penetration Test (SCPT) as per IS:4968(Part-III) - 1976 (Reaffirmed in 2002). To evaluate safe bearing capacity and settlement of cohessionless soil for undrained cohession clays. 'Note: SCPT to be conducted at specified locations as specified in drawing or as directed by Engineer in charge
Conducting Field Pumping ( Pumpin/ Pumpout method) test as per IS: 5529 (Part-1)-2013 as per specification. 'Note: This test to be conducted at BH5 & BH12. or as specified by Engineer in Charge.
Conducting Cyclic plate load test (CPLT) as per IS : 5249 :1992 to determine the value of Coefficient of Elastic uniform compression(Cu).
Conducting Pressure meter test in NX size borehole in soft rock & hard rock with electronic probe for pressure up to 200 bar or failure which occures earlier and submitting the test data and computed parameters (like Em,PL,Creep etc.)as per IS12955(Part-2)1990 reaffirmed in 2001. at specified bore holes .( One set of test consistes of testing at 4 elevations in boreholes) 'At depth corresponding to RQD-25%
Conducting Pressure meter test in NX size borehole in soft rock & hard rock with electronic probe for pressure up to 200 bar or failure which occures earlier and submitting the test data and computed parameters (like Em,PL,Creep etc.)as per IS12955(Part-2)1990 reaffirmed in 2001. at specified bore holes .( One set of test consistes of testing at 4 elevations in boreholes) 'At depth corresponding to RQD-50%
Conducting Pressure meter test in NX size borehole in soft rock & hard rock with electronic probe for pressure up to 200 bar or failure which occures earlier and submitting the test data and computed parameters (like Em,PL,Creep etc.)as per IS12955(Part-2)1990 reaffirmed in 2001. at specified bore holes .( One set of test consistes of testing at 4 elevations in boreholes) 'At depth corresponding to RQD-75%
Carrying out Sand bath method Alcohol Method test as per IS:2720 (Part II)-1973 (Reaffirmed 2010) to evaluate Water content .The test is to be conducted on one or more DS (disturbed sample )collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'NOTE: Bore holes and Rocky strata where test to be conducted shall be location as specified in drawings. Level as per RQD./Borelog details and specified by Engineer in Charge.
(II) Laboratory tests on Soil 'Determination of Grain size distrubtion,percent fines of soil sample by conducting Grain Sieve analysis & Hydrometer analysis as per IS:2720(PART 4) -1985(Reaffirmed in 2006) . The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'Sieve analysis.
(II) Laboratory tests on Soil 'Determination of Grain size distrubtion,percent fines of soil sample by conducting Grain Sieve analysis & Hydrometer analysis as per IS:2720(PART 4) -1985(Reaffirmed in 2006) . The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'Hydrometer or Pipette analysis
Determination of soil classification,identification, evaluating percent fines as per IS:1498-1970(Reaffirmed in 2007). The test is to be conducted on one or more DS(disturbed sample) & UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC, submission of test result as directed by EIC.
Determination of Specific gravity, natural moisture content, voids ratio by conducting Density bottle method , Pycnometer method test as per IS2720(Part III/Sec1 or Sec2 )-1980 (reaffirmed in 2002)along with submission of test result as directed by EIC. The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC.
Water content from UDS by oven drying method as per IS : 2720(Part II) - 1973.
Determination of Liquid limit, plastic limit atterberg limits and plasticity index of soil sample as per IS: 2720 (part5)-1985 Reaffirmed in 2006. The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC.
Determination of Shrinkage limit and shrinkage ratio of soil sample as per IS: 2720 (part-VI)-1972 Reaffirmed in 2001. The test is to be conducted on one or more DS(disturbed sample ) &UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Carrying out Chemical analysis of sub soil samples to evaluate chemical characteristics of soil including pH,Sulphates(SO3&SO4),chloride and nitrate contents,organic matter, chemicals salinity and any other chemicals harmful to the foundation material as per IS: 2720 (Part 23,24,25,26 and 27) in an approved laboratory, complete as per specifications, including submission of test report .The test is to be conducted on one or more DS(disturbed sample) &UDS(undisturbed sample) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Same as in Item No. 28 above, but on 2:1 water:soil extract of the soil samples, giving sulphates as SO3 only.
Chemical analysis of sub-soil, ground water&soil-water mixture as per relevant IScodes for determining chemical characteristics of water&soil such as colour,odour,turbidity ,pHvalueand specific conductivity at 25deg.Cand chemical contents such as carbonates,sulfates (both SO3and SO4), chlorides,nitrates,organic matter and any other chemical harmful to the foundation material . The test is to be conducted on one or more water samples collected from each borehole. water samples, including alkalinity sulphates as SO3 & SO4, chlorides, Nitrates, pH, turbidity, flouride, free and saline ammonia content, hardness etc., organic content ,soluble salt content and any other chemical & harmful chemicals . etc
Constant head & falling head permeability test as per IS : 2720(Part 17& Part36) Reaffirmed in 2002.
Carrying out Direct Shear Test (UU,CU,CD) (for cohesionless soil) as per IS:2720 (Part 13)-1986 (Reaffirmed 2002) to evaluate Cohesion and Angle of internal friction (CD test), Shear Strength, Shear Modulus (Static), ELastic Modulus (Static) Coeficient of Consolidation (for CD test) .The test is to be conducted on one or more UDS (undisturbed sample ) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'Cohesion and Angle of internal friction
Carrying out Direct Shear Test (UU,CU,CD) (for cohesionless soil) as per IS:2720 (Part 13)-1986 (Reaffirmed 2002) to evaluate Cohesion and Angle of internal friction (CD test), Shear Strength, Shear Modulus (Static), ELastic Modulus (Static) Coeficient of Consolidation (for CD test) .The test is to be conducted on one or more UDS (undisturbed sample ) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'Shear Strength
Carrying out Direct Shear Test (UU,CU,CD) (for cohesionless soil) as per IS:2720 (Part 13)-1986 (Reaffirmed 2002) to evaluate Cohesion and Angle of internal friction (CD test), Shear Strength, Shear Modulus (Static), ELastic Modulus (Static) Coeficient of Consolidation (for CD test) .The test is to be conducted on one or more UDS (undisturbed sample ) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'Shear Modulus
Carrying out Direct Shear Test (UU,CU,CD) (for cohesionless soil) as per IS:2720 (Part 13)-1986 (Reaffirmed 2002) to evaluate Cohesion and Angle of internal friction (CD test), Shear Strength, Shear Modulus (Static), ELastic Modulus (Static) Coeficient of Consolidation (for CD test) .The test is to be conducted on one or more UDS (undisturbed sample ) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'Elastic Modulus
Carrying out Direct Shear Test (UU,CU,CD) (for cohesionless soil) as per IS:2720 (Part 13)-1986 (Reaffirmed 2002) to evaluate Cohesion and Angle of internal friction (CD test), Shear Strength, Shear Modulus (Static), ELastic Modulus (Static) Coeficient of Consolidation (for CD test) .The test is to be conducted on one or more UDS (undisturbed sample ) collected from each borehole or alternate&staggered boreholes and representative of each soil stratum as directed by the EIC. 'Coeficient of Consolidation
Triaxial compressive Strength Test on undisturbed soil samples or on soil samples compacted to specified density. Tests to be conducted asper IS:2720 (Part11)-1993 (Reaffirmed in 2002) 'Unconsolidated Undrained
Triaxial compressive Strength Test on undisturbed soil samples or on soil samples compacted to specified density. Tests to be conducted asper IS:2720 (Part11)-1993 (Reaffirmed in 2002) 'Consolidated Undrained, including bore water pressure measurement
Unconfined compressive strength test as per IS: 2720 (Part10) 1991 (Reaffirmed in 2006) on undisturbed soil samples or soil samples compacted to specified density to determin safe bearing capacity, compressive & shear strength of soil.
Consolidation tests on undisturbed soil samples or on soil samples compacted to specified density, giving full test results including unit weights, specific gravity, e-log p curve, virgin curve, P0, eo, Cc, Cv and mv for all pressure increments etc. (Tests without presentation of these results will not be paid for.)
Carrying out Proctor Density Test as per IS:2720 (Part 7)-1980 to evaluate Bulk density, Dry Density, Optimum Moisture Content. The test is to be conducted on one or more DS (undisturbed sample ) collected from each borehole or alternate & staggered boreholes and representative of each soil stratum as directed by the EIC.
Evaluation of Liquefaction Potential based on the other tests conducted in laboratory on undisturbed or remoulded samples of soil. ' NOTE: The UDS shall correspond to each soil stratum. Hence can be decided only after receipt of borelog data. Test to be done in each or alternate boreholes and 2 samples assumed per borehole.and as decided by the design Engineer.
(III) Laboratory tests on Rock 'Carrying out petrographic examination of rock sample as per ASTM: C-295 for determination of core recovery, rock quality designation and rock mass rating in each borehole, for each rock stratum and submission of test result as directed by EIC.
Determination of water content,Porosityand density [saturated surface dry &wet condition], specific gravity by conducting Caliper,Buoyancy,Mercury Displacement techniques as per IS: 13030-1991(Reaffirmed 2001) . The test is to be conducted on one or more rock sample representative of each rocky stratum collected from each borehole.
Conducting Water absorption test as per IS: 1124-1974( Reaffirmed 2003) to evaluate water absorption . The test is to be conducted on one or more RS representative of each rocky stratum collected from each/alternate borehole.
Conducting test of Chemical analysis of rock cores .
Carrying out Unconfined compression strength (UCS) test on soaked & unsoaked samples for determination of Poisson's ratio,modulus of elasticity ,shear modulus as per IS:9221-1979(reaffirmed 2001)along with unconfined compressive strength,safe bearing pressure of rock sample as per IS: 9143-1979(reaffirmed2001)in each borehole (BH-1to 21) and submission of test result as directed by EIC. 'without saturation
Carrying out Unconfined compression strength (UCS) test on soaked & unsoaked samples for determination of Poisson's ratio,modulus of elasticity ,shear modulus as per IS:9221-1979(reaffirmed 2001)along with unconfined compressive strength,safe bearing pressure of rock sample as per IS: 9143-1979(reaffirmed2001)in each borehole (BH-1to 21) and submission of test result as directed by EIC. 'with atleast 7 days saturation
Brazilian test on rock core as per IS:10082-1981 (Reaffirmed 2001)to evaluate tensile strength, in boreholeand submission of test result as directed by EIC.
Detremination of Safe bearing pressure by conducting Point load strength test of rock sample as per IS:8764 - 1998 (reaffirmed 2008) & IS:10082 - 1981 (reaffirmed 2001) in each borehole (BH-1 to 21) at 3.0m,6.0m,9.0m,12.0m,15.0m, 18.0m,21.0m,24.0m,27.0m,30.0m and submission of test result as directed by EIC.
Construction of pillars at as directed in Brick work in CM 1:5 of size 345 mm X 345 mm with plain cement concrete of 1:5:10 base coarse of 100 mm thick. Brick work shall be 200 mm height below ground level and 400 mm height above ground level .Top surface of the pillar shall be plaster with CM 1:5 12 mm thick with floating coat of neat cement slurry and marking the co-orinates in paint. The rate includes required earth work etc complete .The work shall be as per specification and as per direction of Engineer in charge
(IV) Report 'Preparation and submission of Three (3) hard & soft copies(on DVD) of Draft reports as specified followed by Five (5) hard copies of Final report of Geotechnical Investigations as detailed in specifications along with 6 soft copies of the same on the DVD. 'Note: 1. Final Report to be submitted shall include recommendations for the geotechnical investigation consisting of deliverables as per FORMAT - 2 which will be issued to the successful bidders. '2. Geotech Investigations for Soils and Rock will be carried out to evaluate the different type of test values as per FORMAT - 1 which will be issued to the successful bidders.
Gaveshana Geosciences Pvt Ltd (BID ID -3103843)
M/s. S and R Geotechniques Pvt.Ltd. (BID ID -3104724)
Renuka Consultants (BID ID -3101463)
SKW SOIL AND SURVEY CO (BID ID -3101557)
Bureau Veritas (India) Pvt. Ltd (BID ID -3103815)
Geo Designs and Research Pvt Ltd (BID ID -3105095)
MYRTLE PROJECT AND CONSULTANCY PRIVATE LIMITED (BID ID -3104727)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .