Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Sh Sachin Jaiswal, IDSE, CWE Chandimandir
HQ CWE Chandimandir
CA NO. CWE/CHM(U)-61/2022-23 DAY TO DAY MAINT OF ESSENTIAL ELECTRIC SERVICES OF HT/ LT POWER SUPPLY SYSTEM AT CHANDIMANDIR MIL STN.
2023_MES_574204_1
CWE/CHM(U)-61/2022-23
Open Tender
Miscellaneous Works
Item Rate
330 days
HQ CWE Chandimandir
Class C Category b(ii)
8 documents required · 8 mandatory
₹1,000
Yes
GE (U) Chandimandir
₹1.2 L
Yes
12 Apr 2023
10 Jan 2023
24 Feb 2023
10 Jan 2023
20 Feb 2023
6 Feb 2023
11 Jan 2023 - 21 Jan 2023
Amount
Excavation in trenches in soft/loose of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth, for laying of cable, poles, stay etc. and getting out complete all as specified and directed.
All as item No.01 above but depth exe 1.5 mtr and not exe 3.0 mtr complete all as specified and directed.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified and directed.
Removing excavated soil to a distance not exceeding 100 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, class HPV, type 1 flat , size 300mm x 180mm x 40mm including taking out damaged cable cover complete all as specified and directed.
M & L dry sand filling under and around UG cable and in cable ducts to provide cushioning complete all as specified and directed.
Finding of fault to 11 KV UG cable with suitable fault locator equipment & pin point the fault in the faulty cable including putting a TMT bar of length not exc 80 cm (atleast 40 cm below ground level and remaining portion exposed) and wrapping red colour cloth on the top portion of the TMT bar complete all as specified and directed.
M&L for rectification of the fault located by fault locator equipment by excavating the affected area upto a certain length , width and depth , cutting and if required, replacing the faulty part of the cable with new XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cable as per exisitng size and jointing with HT straight through heat shrinkable type cable jointing kit for 11 KV grade of suitable size and making the surface good as existing by relaying the rectified cable , sand cushioning, laying of cable cover, returning filling , removal of surplus soil etc. complete all as specified and as directed. Note - (a) Excavation work, returning filling work, removal of surplus soil, sand cushioning, laying of HT grade cable cover shall be measured and paid separately under respective items of the BOQ. (b) Cable jointing kit and XLPE cable of required length, if any shall be measured and paid separaetly under respective items. (c) Cost of necessary T&P shall be deemed to be included in the quoted rates.
Supply only HT straight through heat shrinkable type cable jointing kit for 11 KV grade, XLPE cable of size 95 sqmm 3 core complete all as specified and directed.
All as per item No 9 above but cable of size 120 to 185 Sqmm, 3 core. complete all as specified and directed.
All as per item No 9 above but cable of size 240 Sqmm, 3 core. complete all as specified and directed.
Material and labour for E-watch online EMS with annual subscription charges paid having features of 1, 3, 5, 15, 30, 60 minutes data reading / pooling frequency, real time personalized dashboards, historical graphs and trends views, alarms, downloadable reports via e-mail or spreadsheet reports, carbon monitoring, mobile app/alerts, on demand reports, open access / scheduled demand analysis, 03 Nos simultaneous users complete all as specified and directed.
M&L for Annual Maintenance contract for eleven months skyline gateway communication module, with 2 No's RS 485 input port with half duplex, screw terminals & upto 115200 bps, cellular 4G/3G/2G fall back with dual Nano SIM port, 1 No. Ethernet port with 10/100 Mbps, PVV4/PV6, over RJ-45, WiFi support IEEE 802.11 b & 2.4 GHz- 03 Nos for 10 Nos meters complete all as specified and directed. Note :- Cost of spare parts incorporated shall be deemed to be included in the quoted rate.
Supply and fixing in repairs only electrical panel doors fabricated from MS sheet as per existing size and shape and fixed with hinges by properly welding and checking for proper closing and opening complete all as specified and directed. Note:- Repairing and refixing of one door panel fitted with 2/3 hinges shall be considered as one job. Any small piece of MS sheet of thickness 2/3 mm required for repairing the portion of the door to be fixed with hinges and replacing any damaged MS hinge shall be deemed to be included in the unit rate quoted.
Disconnecting and taking out old unserviceable panel of any type and size complete all as specified and directed.
Disconnecting and taking out defective HT cable of any size complete including joints/protection pipes etc from trenches/ducts/poles etc complete all as specified and directed.
Taking out old damaged PCC pole of any size incl breaking PCC foundation and clearing the site complete all as specified and directed.
M & L GI pipe 100 mm bore light grade fixed for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
M & L PCC 1:4:8 type D-2 using 40 mm graded crushed stone aggregate as in pole foundations etc complete all as specified and directed.
M & L PCC 1:3:6 type C-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including necessary form work complete all as specified and directed.
M & L PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate in pole / strut coping complete all as specified and directed.
S & F in trenches, ducts or fixing along the poles or passing through pipes or laid under floors etc and testing XLPE insulated , screened PVC bedded, galvanised steel strip armoured, heavy duty HT power cables ISI marked with aluminium conductor, size 95 sqmm 3 core, 11 KV earthed, complete all as specified and directed.
All as per item No 22 here-in-before but 120 Sqmm 3 core complete all as specified and directed.
All as per item No 22 here-in-before but 150 Sqmm 3 core complete all as specified and directed.
M & L in replacement cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts , washers, welding, bending ( cold or hot ) drilling holes for bolts bent to any shape or size as indicated or directed inclusive of one primer coat of red oxide primer and aplying two coats of aluminium paint complete all as specified and directed.
S & F in replacement outdoor gang operated air break switches 12 insultors vertical isolation type, triple pole, manually operated, mounted on insulators and steel frame complete with all accessories & drop out fuse unit, with operating mechanism worked from ground level for rating 400 Amps, 11000 volts complete with GI operating pipe of heavy duty grade of suitable length complete all as specified and directed.
All as per item No 26 here in before but of capacity 200 amps complete all as specified and directed.
S & F steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-55 (11 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified and directed. NOTE: Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
M & L GI pipe 80 mm bore light grade fixed for cable protection on poles/walls/under road/culvert etc complete all as specified and directed.
Supply, install, commissioning and testing of CPRI approved make out door type double door floor mounting feeder pillar box , fabricated out of 3.15 mm thick MS sheet and MC 75 channel for base frame work & angle iron 50 x 50 x 6 mm for legs , 04 nos legs 750 mm long ,all surfaces duly powder coated , with and incl locking arrangement on front and rear side doors, dust / vermin and water proof , suitable for 3 phase 4 wire 415 volts 50 Hz AC supply comlete with and incl the followings :-
M&L for rectification of faults in outdoor type 11 KV HT panels by carrying out necessary reapir work like setting up the protection relays , checking for and clearing the fault on Fault Level Indicator meter, tripping the RMU with the help of handle, opening the panel doors by properly earthing the internal circuit, decarbonizing the conducting parts with CRC power spray, dehumidifying the RMU panel by setting up the heating elemment and thermostat in the panel, cleaning the carbon out with dry cotton and making the HT panel ready for re-operation by resetting the relays and completing the internal circuit of the RMU, complete all as specified and as directed. Note - Spares shall be measured and paid in respective items.
Supply and fixing in replacement steel tubular swaged poles complete with mild steel base plate, closed at top as specified, type 410 SP-31 (9 metre long) including painting with two coats of black bitumonous paint externally up to the planted depth and internally through out and remaining external portion with two coats of aluminium paint , over a coat of red oxide primer complete all as specified and directed. NOTE: Excavation & earthwork, foundation concrete will be meaured & paid for separately under respective item(s).
M&L for Earthing complete with galvanised steel earth plate electrode 60x60cmx6 mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised earth lead strip 32x6mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point panel all as specified or indicated and testing on completion including necessary excavation & earth work in any type of soil, funnel, PCC chamber (1 : 3 : 6) type C1, CI pit cover and frame , charcol, salt including earth lead protected by 40 mm dia medium grade GI pipe and 20mm dia medium grade GI Pipe for watering complete. Note :- Earth lead strip 32 x 6 mm and GI 40 mm dia protecion pipe upto 7.5 mtr length will be deemed to include in the unit rate quoted complete all as specified and directed.
Supply, installation and testing of ICT (Inter Connecting Transformer) for connecting between the main CTs and protection relays in the control & relay panels of MES HT 11 KV feeders at main 11 KV feeders control panel at main grid sub station including taking out unserviceable having the following specifications:- Ratio-0.387/0.577A , VA-15, Class-5P20, Type-BPL R/C, Frequency- 50 Hz, LV-660 volt
Excavation in trenches in hard/ dense soil of any depth and width, for laying /taking down of cables, poles, stay etc. with earth excavator, completing the specified job, returning filling including well ramming of soil, removal of surplus soil to a distance not more than 100 m as directed complete all as specified and directed by Engineer-in-Charge Note- 1. The excavation work shall be carried out in the presence of contractor or his supervisor. 2. The cost of any damage to existing underground electric cable, OFC, water pipeline etc. shall be borne by the contractor.
M&L for Shifting of transformers/ PCC Poles/ Steel Tubular Poles using hydra/crane etc of suitable size from existing position/site and fixing on another site/pole structure/plinth/store yard including necessary connections /disconnections complete all as specified and directed. Note- Excavation work , PCC Work if required shall be measured and paid separately in respective items of BOQ.
Supply and installation in replacement incl connecting and testing of AC/DC back up system for HT 11 KV panel boards comprising of 1500 VA or nearest higher size capacity, single phase 220/240 volts, 50 Hz microprocessor control invertor system with overload/overcharge/deep discharge protection system, LED display, fitted with relays and other controls, DC charging system, two nos 12 volt 180 AH lead acid batteries connected with heavy duty copper leads and brass terminals. System having input AC 240 volt single phase or DC 24 Volt and output 220/240 volts AC single phase complete including suitable trolley/cabin for housing the entire system, input AC supply leads & output AC supply leads copper conductor of appropriate size and making all connections with the control wiring terminals of HT 11 KV VCB panels complete all as specified and directed.
Supply and fix LED Flood Light luminaire in replacement high power with Maximum system wattage of 150 Watt, system lumen efficacy not less than 95 lumens per watt, total system lumens not less than 14250 lumens, PF>0.90, CRI not less than 70, THD not more than 10 %, surge protection not less than 5 KV, colour temp 5700k to 6500k, operating voltage ranging from less than 120V to more than 270 V at 50 Hz AC frequency, glare free elagently designed highly efficient Pressure die cast aluminium housing in powder coated finish heat resistant toughened glass , gasket provides high degree of protection, Delivers high light output, Fins provided on housing for better dessipation luminaire IP 65 Class -I complete all as specified and directed.
Taking down fire fighting extinguishers cylinder from the fire stand / wall and refilling of Gas cylinder with multi purpose dry powder suitable for class ABC cylinder of any capacity including hydraulic pressure testing of cylinder complete all as specified and directed.
Supply and fixing in repair HT heat shrinkable type outdoor end termination cable jointing kit suitable for 11 KV (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed.
All as per item No 40 above but cable of size 120 to 185 Sqmm, 3 core. complete all as specified and directed.
All as per item No 40 above but cable of size 240 Sqmm, 3 core complete all as specified and directed.
Supply and fixing in reapair HT heat shrinkable type indoor end termination cable jointing kit suitable for 11000 volt (Earthed) grade XLPE cable of size 95 Sqmm, 3 core complete all as specified and directed.
All as per item No 43 above but cable of size 120 to 185 Sqmm, 3 core complete all as specified and directed.
All as per item No 43 above but cable of size 240 Sqmm, 3 core complete all as specified and directed.
M&L for repair of any type of breakdown in HT four pole / two pole structure by carrying out necessary rectification work and ensuring the availabilty of electric supply in the affected area, including taking down the old defective parts like HT jumpers, moving/ fixed contact blades , MS jumper carriers , tinned copper flexible wires woven connecting jumpers etc. of GOAB switch of cap 400 A/ 200 A, HT pin type / disc type porcelain insulators, HT fuse wires off size, HT barrel fuse etc. and replacing the same with new ones in stipulated period of time complete all as specified and as directed. Note :- (a) The items required for the repair shall be measured and paid separately under respective items. The cost of taking down of old unserviceable/burnt material shall be deemed to be included in the quoted rates. (b) Conveyance and necessary T&P , ladders etc for maintaining the services shall be provided by the contractor and unit rate quoted will be deemed to include the cost of the same. (c) Repair work shall be initiated within an hour of receipt of intimation of breakdown by JE/ Engineer-in-charge otherwise a penalty of Rs 500 per hour per event shall be levied to the contractor.
Supply only jumpers in red/yellow/blue colour for HT lines/connections made from aluminium conductor single core PVC insulated cable of suitable size complete including winding wires, aluminium tapes etc. complete all as specified and directed.
Supply only moving contact blade (male contact) suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 200 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only moving contact blade (male contact) suitable for 400 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only spring loaded fixed contacts (female contact jaw) suitable for 400 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only tinned copper flexible wires woven connecting jumper suitable for 400 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only MS jumper carrier for 400 amps 11000 volts outdoor GOAB switch complete all as specified and as directed.
Supply only copper tinned fuse wire complete all as specified and directed.
Supply only LT insulation tape ( FR PVC electrical insulation tape ) 0.125 mm thick , 1.80 cm width and 25 mtr length. complete all as specified and directed. Make - Steelgrip/Anchor or as approved by GE.
Supply only HT insulation tape FR, 0.75 mm thick , 1.90 cm width and 9.0 mtr length packed in box. complete all as specified and directed. Make- Kappa/3M Scotch/Gemini or as approved by GE
Supply only GI nuts/bolts/washers
Supply only HT 11 KV barrel fuse of capacity 10A to 100A
Supply and fixing in repair wall mounting indoor type 200 amps capacity 8 way TPN busbar chamber 415 volts in sheet steel enclosure complete including making all incoming and outgoing cable connections complete all as specified and directed.
Supply and fixing in repair main switch with rewireable fuses in sheet steel enclosure capacity 200 amps TPN 415 volts with and including porcelain fuses complete including making all incoming and outgoing cable connections complete all as specified and directed.
Supply and fixing in repair changeover switch off load type in sheet steel enclosure capacity 250 amps FP 415 volts including making all incoming and outgoing cable connections complete all as specified and directed.
M&L for repair of any type of breakdown in LT Panel / pillar box box of any size by carrying out necessary rectification work including disconnecting the LT cable, taking down any burnt/ unserviceable parts like MCCBs of any rating, onload changeover switch of any rating, aluminium lug eye type of any size, decarbonizing and cleaning the conducting parts of the panel with CRC power spray, replacing the unserviceable parts with new one, dressing the cable properly with LT insulation tape and restoring back the electric supply including ensuring the availabilty of electric supply in the affected area complete all as specified and as directed. Note :- (a) The items required for the repair shall be measured and paid separately under respective items. The cost of taking down of old unserviceable/burnt material shall be deemed to be included in the quoted rates. (b) Conveyance and necessary T&P for maintaining the services shall be provided by the contractor and unit rate quoted will be deemed to include the cost of the same. (c) Repair work shall be initiated within an hour of receipt of intimation of breakdown by JE/ Engineer-in-charge otherwise a penalty of Rs 500 per hour per event shall be levied to the contractor.
Supply only heavy duty aluminium lugs eye type of size 16 to 35 sqmm. complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 50 to 95 sqmm. complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 120 to 185 sqmm. complete all as specified and directed.
Supply only heavy duty aluminium lugs eye type of size 240 to 400 sqmm. complete all as specified and directed.
Supply only on load type changeover switch without enclosure 630 amps capacity four pole 415 volts complete all as specified and directed.
Supply only on load type changeover switch without enclosure 800 amps capacity four pole 415 volts complete all as specified and directed.
Supply only MCCB 63 amps to 100 amps four pole 27 KA breaking capacity 415 volts with adjustable thermal and fixed magnetic release and Icu = 100 % Ics complete all as specified and directed.
All as item no. 71 above but of capacity 125 to 160 Amps 27 KA breaking capacity complete all as specified and directed.
All as item no. 71 above but of capacity 200 to 250 Amps 36 KA breaking capacity complete all as specified and directed.
All as item no. 71 above but of capacity 320 to 400 Amps 36 KA breaking capacity complete all as specified and directed.
All as item no. 71 above but of capacity 630 Amps 36 KA breaking capacity complete all as specified and directed.
M&L for repair of any type of breakdown in LT electric supply due to fault in LT cable of any size , by carrying out the rectification work including location of fault in LT cable, disconnecting the electric supply of the cable, cutting the affected cable and making arrangements for joining the cable ends with aluminum inline connectors complete all as specified and as directed. Note - Spares shall be measured and paid in respective items. complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 16 to 35 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 50 to 95 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 120 to 185 sqmm complete all as specified and directed.
Supply only heavy duty aluminium in line connector of size 240 to 400 sqmm complete all as specified and directed.
Supply and fixing in repair chequred rubber mat for electrical purpose ISI marked of size 1 mtr X 2 mtr and 19 mm thickness complete all as specified and directed.
M&L for rectification of faults in indoor type 11 KV HT panels by carrying out necessary repair work like setting up the protection relays , clearing the fault on Fault Level Indicator meter, tripping the VCB, taking the trolley out, decarbonizing the conducting parts with CRC power spray, dehumidifying the VCB panel by setting up the heating element and thermostat in the panel, cleaning the carbon out with dry cotton and making the HT panel ready for re-operation by resetting the relays and mount the VCB trolley in, complete all as specified and as directed. Note - Spares shall be measured and paid in respective items.
Supply only CRC 2-26 power spray 500 ml bottle complete all as specified and directed.
Supply and fixing in repair bare copper conductor of any size complete all as specified and directed.
Supply and fixing in repair HT cable boots for HT end termination suitable for 11 KV HT RMU of any make and type complete all as specified complete all as specified and directed.
Bharat Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .