Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.3 LAccepted-AOC | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹26.0 L+₹1.8 L (7.54%)Rejected-Finance RZ 382 3RD FLOOR GALI NO 11B KAILASH PURI EXTN PALAM COLONY PALAM VILLAGE NEW DELHI 110045 | SOUTH WEST | DELHI | 110045 | L2 | Rejected-Finance Not Being Lowest | |
| 3 | L3₹27.0 L+₹2.9 L (11.9%)Rejected-Finance | L3 | Rejected-Finance Not Being Lowest | |
| 4 | L4₹29.7 L+₹5.5 L (22.8%)Rejected-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance Not Being Lowest | |
| 5 | L5₹29.7 L+₹5.5 L (22.8%)Rejected-Finance | L5 | Rejected-Finance Not Being Lowest |
Tender Value
₹32.5 L
EMD Value
₹64,900
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (West) Delhi Cantt-10
GE (West) Delhi Cantt-10
Balance work of Spl Repair of 05x OR Bathrooms at 629 TPT Coy ASC in the area of AGE B/R-III under GE (West) Delhi Cantt-10
2024_MES_663885_1
GE/DW-56 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
DELHI
Class D Category a (I)
8 documents required · 8 mandatory
₹500
GE (West) Delhi Cantt
₹64,900
Yes
5 Oct 2024
4 Jul 2024
6 Sept 2024
4 Jul 2024
3 Sept 2024
20 Jul 2024
Amount
Dismantling floor, hearth tiles including cement mortar bedding (but not backing) removing serviceable tiles and rubbish out of premises, complete all as specified.
Demolition of brickwork or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and as directed.
M&L for brick work with sub class 'B' old size bricks in cement mortar 1:6, straight or curved on plan exceeding 6m mean radius complete all as specified and as directed.
M&L for Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 on wall surface complete all as specified and as directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) for plinth protection laid in bays and finished even and fair including filling the joint with bitumen mastic all as specified and directed over rammed earth complete all as specified and as directed.
S&F joint free coloured Non-skid ceramic tiles 6 to 7 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
Fixing only joint free coloured Non-skid ceramic tiles 6 to 7 mm thick (square/ rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for Glazed ceramic tiles of size 300X450X7mm on vertical surface, set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles over 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Fixing only for Glazed ceramic tiles of size 300X450X7mm on vertical surface, set and jointed in neat cement slurry and pointed in white or colour cement to match coloured tiles over 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces complete all as specified and as directed.
Taking down cement or cement lime plaster, any description, on brick or stone walls incl racking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster in cement 1:4 on brick work or concrete surfaces finished even and fair complete all as specified and as directed.
M&L for rendering 15mm thick cement plaster in cement 1:6 on brick work or concrete surfaces finished even and fair complete all as specified and as directed.
M&L for rough cast plaster, applying the under coat of cement and sand mortar 1:3 not less than 10 mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone of size between 6 to 12 mm mixed with coarse sand and cement in the ratio of 1: 1: 1 shall be applied and finished even complete all as specified and directed.
M&L for providing keyed pointing in cement mortar 1:4 including raking out joints/ pointing to brick work in walls or to bricks on edge in floors, surface channels, roofs, etc complete all as specified and directed.
M & L for 10 mm thick rendering in cement mortar 1:3 on concrete surfaces of ceiling, chajja and like surface finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of new surfaces (plastered or un-plastered) on ceiling and applying three coats of white lime wash, complete all as specified and directed.
M&L for complete removal of existing treatment on old ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for complete removal of old decorated surfaces on walls/brick surface and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparing newly plastered/rough cast surfaces on walls and applying two coats of cement base paint over a coat of primer complete all as specified and directed.
M&L for preparing newly plastered surfaces on walls and applying three coats of white washing (undecorated surface) complete all as specified and directed.
M&L for complete removal of existing treatment on walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of syntethic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of new steel & iron surfaces of any description over 10cm in width or girth not otherwise described and applying two coats of syntethic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frame) exceeding 1.5 sqm but not exceeding 4 sqm each complete all as specified and directed.
All as per item No. 24.00 here-in-before but not exceeding 1.5 sqm each.
S&F mild steel framed work in doors/windows frames or gates of angle or other section conforming to Fe-250 with rail, braces, holdfast, etc complete incl fixing of hinges and fixing in position complete all as specified and directed.
S&F 35mm thick second class hard wood (Hollock) plain framed panelled shutters (Minimum two panels) with lock rail and panels of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The sizes of rail and stiles as per IS:1003 ( Part I), kiln seasoned and chemically pressure treated and fixed in position complete all as specified and directed.
Fixing only 35mm thick second class hard wood (Hollock) plain framed panelled shutters (Minimum two panels) with lock rail and panels of 9mm thick BWP commercial ply or 12mm thick veneered particle board with commercial veneering on both faces. The sizes of rail and stiles as per IS:1003 ( Part I), kiln seasoned and chemically pressure treated and fixed in position complete all as specified and directed.
S&F 35mm thick 2nd class hard wood (Hollock) glazed / gauged shutters, open, rebated prepared to receive glass , guage etc W/O sash bars for doors as specified in SSR Part I complete all as specified and directed.
S&F PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S&F factory made solid panel PVC door shutters 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail, MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheet for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement complete all as specified and directed.
S&F steel window with side hung shutter including box type hinges with steel handle and steel peg stay complete with glazing bar complete all as specified and directed.
All as per item No. 32.00 here-in-before but without glazing bars.
S&F Butt hinges, extruded aluminium alloy with galvanised, mild steel hinge pin, anodised and fixed, type B-21 100mm size complete all as specified and directed.
S&F for MS Butt hinges, medium, cold rolled mild steel, and fixed of 100 mm size
S&F aluminum anodized barrel tower bolts of extruded section of size 150 mm complete all as specified and directed.
Fixing only aluminum anodized barrel tower bolts of extruded section of size 150 mm complete all as specified and directed.
S&F aluminum handles cast type anodised of size 150mm complete all as specified and directed.
S&F aluminium alloy, anodised, sliding door bolt (length of bolt 250 mm) with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
M&L for 3mm thick sheet glass, ordinary quality and glazing with oil putty in squares n exc 0.5 sqm in each pane complete all as specified and directed.
M&L for 3mm thick figured glass, pin head type and glazing with oil putty in squares n exc 0.5 sq. m in each pane complete all as specified and directed.
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed to tinned tacks or wire staples to wooden frames complete all as specified and directed.
S&F steel ventilator with top hung shutter including friction hinges, steel peg stay, complete all as specified and directed.
S&F in repairs vitreous china squatting pan 'Orissa' pattern,size 580X440mm, including 'P' of 'S' trap, white, with intergral foot rests (excluding flushing cistern and flush pipe) including connection to trap & to flushing pipe,anti syphonage pipe etc incl making good to floor to match with adjoining area complete all as specified and directed.
S&F in repair PVC low level white flushing cistern, valveless syphonic action type 10 ltr capacity with inlet, ball valve, float and handle including PVC flush pipe 32mm dia bend and a pair of mild steel iron brackets of suitable size incl making necessary connection to water supply pipeline complete all as specified and directed.
M&L for Black Granite slab 18 to 20 mm thick rubbed and polished machine cut, set in cement mortar jointed with white cement complete including bedding layer 15mm thick in cement mortar 1:6 over platform incl rounding of exposed edges and polishing, complete all as specified and directed.
S&F in repair tubular towel rail 20mm dia, aluminium anodised, D type, 60cm long between flanges complete all as specified and directed.
Taking up or down 15mm dia steel tubing and connection incl cleaning or removal from the site of work complete all as spd & directed.
All as per item No. 49.00 here-in-before but 20mm dia.
S&F galvanized steel tubing, 15mm bore, medium grade including all fittings and short pieces, fixed complete to walls and ceiling or laid in floors, complete all as specified and directed.
All as per item No. 51.00 here-in-before but 20mm dia.
Fixing only 20mm bore tubes, any grade, to walls and ceilings or laying in floors complete all as specified and directed.
S&F in repair for PVC connection 450mm long with 2 nos PTMT check nuts, suitable for 15mm dia bore complete all as specified and directed.
Fixing only in repair for PVC connection 450mm long with 2 nos PTMT check nuts, suitable for 15mm dia bore complete all as specified and directed.
S&F in repair ball brass valves 20mm dia high pressure with polythene float and fly nut complete screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F in repair gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed for 20mm dia pipe complete all as specified and directed.
S&F in repair CP grating 125mm dia, complete all as specified and directed.
S&F 15mm bore chromium plated fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
Fixing only 15mm bore chromium plated fancy type Bib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed.
S&F in repair Vitreous China urinals, (back or corner wall type), size of 375 x 390 x 590 mm white or ivory colour , complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing to angle valve, grating and union for discharge pipe complete all as spd & directed by Engr-in-Charge.Make -Hindware Cat NO - 60002 or equivalent.
S&F in repairs 15mm dia pillar taps swan neck pattern brass with capstan head chromium plated screwed down high pressure with or without lettered “hot/cold” with long screwed shank and flynut screwed complete all as specified
S&F in repair vitreous china wash down water closet pan (pedestal pattern) european type white including plastice seat cover and connection with cistern including S or P trap complete all as specified and directed.
S&F 15mm bore dia pipe stope valve/angle valve chromium plated fancy type,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed with long shank and cup complete all as specified and directed.
S&F 15mm bore dia pipe concealed type stope valve/angle valve chromium plated fancy type,cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed with long shank and cup complete all as specified and directed.
S&F for Brass Chromium plated shower rose 125mm size with arm with or without swivel joints, any size, including fixing to steel pipe or union suitable for 15mm GI pipe complete all as specified and directed.
S&F in repair vitreous china oval shape WHB white size 560x410mm and pair of C.I. brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe complete all as spd & directed by Engr-in-charge.Make:Hindware ,Cat No : 10017
Fixing only in repair vitreous china oval shape WHB white size 560x410mm and pair of C.I. brackets including cutting for and pinning in ends of brackets or erecting stand with waste pipe complete all as spd & directed by Engr-in-charge.Make:Hindware ,Cat No : 10017
Dismantling of 100mm bore cast iron or PVC drain pipes, jointed in cement mortar and taking out of wall/trenches, if required complete all as specified and directed.
S&F 100mm bore cast iron soil waste and vent pipe (Cast type) in any length with or without ears with cement joints fixed to walls or laid in floor etc complete all as spd & directed.
M&L cast iron floor trap 100mm out let diameter including jointing to waste pipe with lead joints fixed in cement concrete type B-1 (1:2:4) complete all as spd & directed.
S&F for 100mm CI Branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S&F 100mm CI plain bends (any radius) complete all as specified and directed.
S&F 100mm CI bends (any radius) with acess doors complete all as specified and directed.
S&F 100mm CI vent cowl complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft / loose soil complete all as specified and directed.
Demolition and breaking up drain pipes (salf glazed stone ware AC or reinforced concrete) set in cement mortar incl bedding and haunching of 150 mm dia pipe complete all as specified and directed.
M&L cement concrete bed to 150mm dia drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D-2 complete all as specified and directed.
M&L for 150mm internal dia Reinforced concrete pipes, class NP 2 with one collar per length of pipe, laid in trenches and lead jointed complete all as specified and directed.
M&L cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished, and re-forming benching as required for 100mm dia pipe complete all as specified and directed.
M&L providing precast cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) as in manhole covers slab/platform set in cement mortar 1:6 complete all as specified and directed.
Removing excavated soil to a distance not exc 50 Mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
S&F in repair rotational moulded ploythelene water storage tank (cylindrical, vertical with closed top) three layered 1000 ltrs capacity (ISI Marked), incl cover, hoisted and fixed in position complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 (20mm graded agg) as in foundation of manholes complete all as specified and directed.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone agg as in coping, kerbs, bed plates, benching incl weathering, slightly rounded or chamfered angle and throating complete all as specified and directed.
Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) including removal of rubbish outside complex ( MOD land), complete all as specified and directed.
M&L for Reinforced cement concrete (Design Mix) M-25, (using 20mm graded stone aggregate) as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like
M&L for reinforced cement concrete (Design Mix) M-25, (using 20mm graded stone aggregate) as in Beams, cantilevers, bressummers, lintels over 1.5m span and the like complete all as specified and directed.
Use & waste for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors andbeams, etc. complete all as specified and directed.
Use and waste for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as specified and directed.
M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for Mild steel TMT bars 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 (using 20 mm graded stone aggregate) on roof padding with water proofing compound surface finished even and smooth without using extra cement complete all as spd and directed. (Rate of WPC shall be included in unit rate)
M&L for water proofing treatment to roof surface with APP water proofing membrane 3mm thick & weighing not less than 3.0 kg/sqm of approved make black finish & reinforced with non woven polyester matt of min 150 gm/sqm laid over a coat of bitumen primer conforming to IS-3384 @ 0.4 Ltr/sqm over prepared roof surfaces, forcing overlap with a propane or a butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing as per manufacturer's instructions complete all as spd and directed. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make/manufacturer. 3. The APP Membrane to be inserted in the parapet wall/wall by cutting chases of atleast 65X50mm size & making good in CM 1:3.
Fixing only for water proofing treatment to roof surface with APP water proofing membrane 3mm thick & weighing not less than 3.0 kg/sqm of approved make black finish & reinforced with non woven polyester matt of min 150 gm/sqm laid over a coat of bitumen primer conforming to IS-3384 @ 0.4 Ltr/sqm over prepared roof surfaces, forcing overlap with a propane or a butane gas torch with a overlap of 75mm at sides & 100mm at ends & sealing as per manufacturer's instructions complete all as spd and directed. Note :- 1. Water proofing treatment shall be got carried out by the manufacturer or their authorised applicator only. 2. Bitumen primer, bitumen and membrane shall be of same make/manufacturer. 3. The APP Membrane to be inserted in the parapet wall/wall by cutting chases of atleast 65X50mm size & making good in CM 1:3.
M&L for 10 mm thick cement plaster on brick/ concrete surface in CM 1:3, finished even and smooth surface with out using extra cement but mixing water proofing compound at the rate of 2% of cement by weight (WPC shall be paid separately).
Supply only Liquid water proofing compound complete all as specified and directed.
M&L for 40mm thick brick tiles laid on screed bed jointed, grouted in CM 1:3 mixed with 5% crude oil by weight of cement including 15mm thick screed bed in CM 1:4 including dismantling damaged brick tiles in pach work complete all as specified and directed.
All as per item no 99.00 here-in-before but except bricks tiles complete all as specified and directed.
M&L for providing cement concrete 1:2:4 type B-I (20mm graded agg) in roof kerb or mud slops, rounded or chamfered on edges, plinth courses, coping, kneelers, apex stone, kerb water tough and the like including weathering, slightly rounded or chamfered angles and throating as directed incl necessary formwork complete all as specified and directed.
S&F framed work such as grills, grating etc. with ends of bars shouldered and /or riveted , or forged into spikes ;framed guard bars; barred iron doors; ladders; framed balusters; walkways; railings; framework of water tanks and similar works con-forming to Fe290. Gde-E-165 complete all as specified & directed.
M&L for repairing of spalled concrete from ceiling/chajjas/drop in the following stages:- 1. Prepration of existing surfaces like chipping of unsound weak / loose concrete with electric hammer or manually including tapering all edges, making square shoulders of cavities etc. n.exc 50 mm thickness removal of debries, complete all specified and directed by the Engineer-in-charge. 2. Applying rust remover cum passivator Sika rustoff 100 @ 0.20kg/Sqm/per coat or as per manufacturer's specifications to remove rust from existing reinforcement (Make : Sika or equivalent) 3. Applying a epoxy based zinc rich rebar corrosion protection system of product : Fiazin (R) R @ 0.15Kg/Sqm/coat or as per manufacturer's specifications (Make ; Sika or equivalent) 4. Mixing & applying two component Epoxy resin concrete Bonding coat of Sikadur(R)-32 LP A & B @ 0.40 Kg/Sqm(Mixing proportion as per manufacturer's instructions) on prepared RCC surfaces as per manufacture specification including prepartaion of surface by chipping and throughly cleaning of surface complete whereever required over new reinforcement (if required) and as directed by the Engineer-in-charge.(Make : Sika) (Reinforcement will be measured and paid separatley). 5. Apply a pre-batched one component polymer modified cementious patch repair mortar of average thickness 40mm and not exceeding 50mm in layer of 15mm thick each of Product: Sika Mono Top®-122 F as per manufacturer insturctions and as directed by the Engr-in-Charge. 6. Apply aluminised synthetic resin Concrete curing compounds for the prevention of premature water loss from concrete of product: Antisol®-E(WP) @ 0.10 to 0.20 kg/m2 as manufacturers instructions and as directed by the Engr-in-Charge.
S & F TMT bars 8 to 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for beams, columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips as specified and directed.Providing extra reinforcement with TMT bars as per site design requirement including straightening, cutting, bending, placing in position, binding with G.i. wire of 18 gauge etc. complete in all respects. Additional reinforcement with adequate lap length & rings at required spacing shall be tied with existing reinforcement using binding wire or welded complete as per site requirement and directions of Engineer-incharge.
M & L for providing rebar of required length & dia with Sika Anchor Fix ® -3/Mungo/Fischer FISV 390/Hilti RE-500 epoxy resin whereever required in RCC members including power drilling for holes (of size 8 to 10mm of length 80mm to100mm ), cleaning of holes, filled with epoxy to ensure the bond as per manufacturers instructions, complete all as specified and directed by the Engr-in-Charge.
M&L for repairing of cracked slab, columns and beams in the following stages:- Making "V" groove of 5mm wide and 5mm deep over crack line by electrically operated angle grinder with diamond concrete saw blade and cleaning it by air blower and sealing it with polymer modified mortar as directed by the Engineer-in-charge.
Drilling and fixing NRV injection packers in RC members including, (a) Drilling Holes: Drilling holes in structural members at the intervals as per recommendation of engineer in charge. (b) Cleaning of holes: Clean the holes by air blower prior to fixing nozzles. Fixing of Packers: Insert 12 mm dia., 50~75 mm long injection packers in cleaned holes with solvent free, moisture insensitive epoxy resin based putty or equivalent. (c) Cutting of Packers: Cut the packers by cut of wheel after completion of grouting without damaging structural elements complete all as specified and directed.
M & L for shrinkage free low viscous epoxy resin based injection grout. Product: Sikadur®-52 as per manufacturers instructions and as directed by the Engr-in-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n exc 15cm thickness (below or above ground level) all as spd & directed by Engr-in-Charge.
M&L for Cement concrete 1:5:10 type E2 using 40mm graded stone aggregate as in foundations, filling and mass concrete in filling sunken floor all as specified and directed.
M&L for providing 25mm thick cement concrete 1:2:4 type B-0 using 12.5mm graded stone aggregate as in sub base using WPC complete all as specified and as directed.
M & L for protection plaster15mm thick reinforced with virgin polypropylene mono filament fibres with admixture: Sika® Plastocrete Plus @ 0.10 kg per bag of cement, reinforcement: Sika® Fibre h 150 @ 0.9 kg/cum complete all as specified and directed by the Engr-in-Charge. (Product requirements admixture: conforms to IS 2645. Product requirements reinforcement: conforms to ISO 9001-2000 and ASTM C 1116 type III4.1.3; specific gravity: 0.91 kg/ltr; fine monofilament; alkali proof; containing no reprocessed olefin materials).
M&L for 40mm bore GI steel tubes medium grade for spout pipe complete all as specified and as directed.
Prepration of surface of sunken portion and M & L for glass fibre reinforced acrylic modified cementitious coating system as Top coat: SikaTop® Seal-107 @ 1.5 kg/m2 over reinforcement: Sika® Fab-1 over base coat: SikaTop® Seal-107 @ 1.5 kg/m2 etc all as specified and directed.
M&L for water proofing treatment in following stages:- 1. Taking down and rendering in CM 1:3 with waterproofing liquid as per manufacturer's instruction over concrete surface finished even and smooth without using extra cement. 2. One coat of bitumen primer confirming to IS-3384@ 0.30 Kg/Sqm over plastered surface.(Bitumen primer shall be Sika WP shield primer of M/s Sika Ltd or Equivalent). 3. Atatic Polypropylene (APP) water proofing membrane, minimum 3mm thick mineral finish and weighing not less than 4.0 Kg/Sqm with conforming to EN 12311-1, ASTMD 5147, ASTM D6, ASTM D5, EN 1928-1, EN1849-1; elongation at break: (L x T): 40 % ; tear strength(L x T): 150 x 200 N, Impact resistance of 600mm as per EN 12691, Cold Flexibility of -5 °C, manufactured by M/s SikaBit T-130 MG or equivalent as approved by GE, complete all as specified and as directed.
Taking down and refixing gI tubing 40 mm bore medium grade fixed to wall and ceiling including necessary fittings and fixture complete all as specified and as directed.
S&F in repair gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed for 40mm dia pipe complete all as specified and directed.
M&L for marble work, table rubbed and polished both face for urinal partition/wall lining (veneering to wall) 15-18 mm thick in cement mortar 1:3 and pointing with white cement 1:2 using marblr dust with admixture of pigment to match with shade including fixing to wall by cutting chase complete all as specified and as directed.
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete (fitting such as switches, ceiling roses, pendent, regulator socket etc to be measured separately) and making good disturbed surfaces of wall floor etc complete all as specified and directed.
M&L point wiring for normal switches with 1.5 sqmm , single core , multi stranded copper conductor PVC insulated and unsheathed (FRLS) cable 1100 Volts grade, confirming to IS:694, drawn into and including concealed PVC rigid conduits 20 mm including cutting of chases for laying conduit making good the surface as per existing surfaces aas per directed with concealed sunk in pressed steel terminal boxes of 1.6 mm thick factory made and painted with stove enameled black paint covered with 3 mm thick plastic laminated sheet of white colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 sqmm PVC insulated unsheathed cable as earth wire to common earth and connected to earth dolly drawn in same concealed conduit complete all as specified for one light/fan/bell point controlled by 1 one way switch 5 Amps.
All as per item No. 120 above but one three pin 6 Amps socket out let on independent board complete all as specified and directed.
All as per item No. 120 above but one three pin 6 Amps socket out let on same board complete all as specified and directed.
All as per item No. 120.00 above but point wiring of copper cable multi stranded 2.5 Sqmm size for 15 Amps socket outlet on independent board with 2.5 Sqmm size of earth conductor complete all as specified and directed.
Supply and fix in repair switch piano flush button type, single pole, one way 6 amp, 230 V, including connecting complete all as specified and directed.
Supply and fix in repair switch piano flush button type, single pole, one way 15 amp, 230 V, including connecting complete all as specified and directed.
Supply and fix in repair socket outlet multipurpose 2/3 pin, 5 amp flush type, including connecting complete all as specified and directed.
Supply and fix in repair socket outlet 2 in 1, 5 and 15 amp flush type, including connecting complete all as specified and directed.
M & L Sub main wiring using two single core PVC insulated FRLS cable 6 sqmm copper conductor multi stranded and 6.0 sqmm copper conductor insulated cable using as earth wire and drawing in to PVC conduit complete all as specified and directed. Note: Two runs of 6 sqmm copper FRLS cable & one run of 6.0 sqmm copper cable in and including 32mm PVC conduit medium grade will be measured as one unit.
S & F in repair MCB SP 240 Volts, 6-32 Amps 'B' curve, 10 Ka complete all as specified and directed.
S & F in repair MCB double pole, 240 Volts, 40 Amps 'B' curve, 10 Ka complete all as specified and directed.
S & F in repair factory made epoxy polyester powder coated distribution board SPN 8 way fabricated from min 1.6 mm thick CRCA sheet with metal double door (IP-43 protection) fixed flush to wall and suitable for universal mounting and including 200 Amp bus bar, neutral bar, standard DIN rail, earth and cable ties for cable managment, top and bottom removable gland plates with knockouts and suitable for one DP MCB as incomer and 6 SP MCBs as outgoings complete all as specified and confirming to IS8623 alongwith cable end box fror DB all as specified and as directed. Note: MCBs shall be measured and paid separately.
S&F in replacement for building security light fitting LED 35/40 W 230 volts AC outdoor cast aluminium housing, toughened glass, silicon gasket, high power LED with lens for uniform distribution pre-wired and electric connection with suitable size of stranded copper flexible cable including GI bracket 1.5 m with clamps and bolts complete all as specified and directed.
S&F surface mounting 20W LED tube light fitting of 4 feet length connected with 23/0.0076 twin core PVC flexible cable complete all as specifed and as directed.
S&F lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
S&F LED bulbs retrofit pin type 9/10 W 240 V AC 50 Hz complete all as specified and directed.
S & F in repair Ceiling rose, PVC/ polycarbonate, isolated body type three terminal, 240 volt complete all as specified and directed.
S& F exhaust fan 300 mm dia sweep, 1000 RPM, 240 Volt heavy duty with louver shutter and brackets, connection with flexible PVC copper cable 3 core of size 1.5 Sqmm of length from ceiling rose to exhaust fan including nut bolt and washers of suitable size complete all as specified and directed.
Supply and Fixing of five star rated Geysers of cap. 25 Ltr, Electric Driven, Single phase, 240 V, Storage vertical type and heating element 2 KW, inner shell made up of copper, automatic cutoff , including electrical and water connection with hot and cold water connection pipe (PVC type) and fixed on the wall with mild steel fastner 150 mm long and 10 mm dia with pin and bolts complete all as specified and directed.
Cutting of existing water supply main any size upto 25 mm for taking branch connection for taking branch connection of size 15 mm including insertion of tee unequal as required at site or directed.
S & F factory made epoxy polyster coated distribution board( fabtricated from min 1.6 mm thick CRCA sheet) and one metal plug socket and neutral link fixed to wall/column suitable for lexic MCB and including 20Amps MCB single pole suitable for 'C' curve, 10 Ka breaking capacity complete all as specified.
A S CONSTRUCTION CO. (BID ID -3074817)
SHRI JI ENTERPRISES (BID ID -3079761)
SHIVA ENTERPRISES (BID ID -3074935)
UNIQUE BUILDERS (BID ID -3072701)
ABHIMANYU LAMBA (BID ID -3079358)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .