| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.7 CrAccepted-AOC 11 SANJIV BAUG SOCIETY NEW SHARDA MANDIR ROAD PALDI AHMEDABAD GUJARAT 380007 | AHMADABAD | GUJARAT | 380007 | ₹2.7 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹2.7 Cr+₹1.7 L (0.65%)Rejected-Finance | ₹2.7 Cr+₹1.7 L (0.65%) | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹3.0 Cr+₹32.8 L (12.2%)Rejected-Finance COLABA MUMBAI | YAVATMAL | MAHARASHTRA | 445001 | ₹3.0 Cr+₹32.8 L (12.2%) | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹4.9 Cr+₹2.2 Cr (82.4%)Rejected-Finance 2 LETTER OF A W ARD N O N B C C E D CPG 2022 11 05 DATED 04 02 2022 3 LETTER N O N B C C E D CPG 2022 11 06 DATED 04 02 2022 | ₹4.9 Cr+₹2.2 Cr (82.4%) | L4 | Rejected-Finance Other than lowest bidder |
| 5 | Rejected-Technical 184 MAIN STREET NASIRABAD AJMER RAJASTHAN 305601 | - | - | Rejected-Technical Not admitted being not enlisted in eligible category |
Tender Value
₹3.7 Cr
EMD Value
₹4.4 L
Closing Date
30 Jul 2022, 6:00 pmClosed
CHIEF ENGINEER UDHAMPUR ZONE
HQ CHIEF ENGINEER UDHAMPUR ZONE PIN 182121
PROVN OF LIFTS FOR NEW COMMAND HOSPITAL UNDER GE (P) CH UDHAMPUR
2022_MES_531100_1
87782/E8
Open Tender
Civil Works
Item Rate
180 days
udhampur
as per tender documents
9 documents required · 9 mandatory
₹2,000
GE (P) CH UDHAMPUR
₹4.4 L
Yes
28 Sept 2022
15 Jun 2022
6 Aug 2022
15 Jun 2022
30 Jul 2022
16 Jul 2022
Amount
Design, Supply, installation, testing and commissionning of 08 passengers Gearless lifts with machine room to serve G+1 upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, full collective simplex controlled operation, centre opening power doors with door drive (Electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue device system and built in intercom system without hand set & infra red curtain, all as specified herein under:- Note: 1. The Lifts shall be installed by the original eqpt manufacturer only. 2. The Lifts shall be tested by IEM at the time of installation in the attendance of manufacturer. 3. The contractor will carry out telephone wiring from all the lifts to the control room as suggested by the GE/Engr-in-charge and installed telephone with any additional exchage/communication equipment if required. This control room should be able to communicate with all the lifts through telephone 24 hrs unintrupted necessary UPS etc will be provided by the contractor without any additional cost to the department. 4. The lift well is ready for installations of the lift ,drgs of lift well shall be provided by the deptt and designing of the lift shall be as per existing lift well. 5. The contractor shall clear all the debris/mud/dewatering of already constructed lift well before installation of lift and rate for the same shall be deemed to be included in quoted item rate.
(i) Type and capacity of Lift : 08 Passengers.-544kgs (ii) Speed: 1.0 m/sec with single speed motor (iii) Type of Drive : AC variable voltage & variable frequency (iv) Machine room : Located above the hoist way (v) Travel - 4.35 Mtrs (Approx) (vi)Serving : ground to 1st Floor( Floor designations will be 0,1) (vii) No of stop : 2 (viii) Lift to be adjusted in RCC constructed clear hoist way ofsize 1950mm(W) x 1850mm(D) (After plaster in plum) (ix) Power supply: 415 Volts, 3 phase, AC, 50 Hz (x) Auxiliary : Single phase 220 volt 50 C/s AC (xi) Car size (inside): 1100mm (W)x 1300mm(D)x2200mm(H) (xii) Pit depth : 1600 mm (xiii) Head room : 5000 mm (xiv) Car enclosure: Car ceiling : SS hairline finish ceiling with fan(CT002), Car panels : SS hairline finish panels, Car Flooring : Aluminium chequered plate flooring, Car Illumination : LED lights (xv) No of entrance -Front opening in all landings (xvi) Car entrance : Centre opening, power doors in stainless steel hairline finish. (xvii) Door safety : Full height infra red curtain (xviii) Landing Entrance: Centre opening, power doors in stainless steel hairline finish for car & landing at all floors (xix) Clear opening : 800mm(W) x 2000mm (high) (xx) Control : Full collective simplex (xxi) Indicators: (a) Car: KDS300 COP-Partial height with seven segment Red indicator and round surface mounted butttons. (b) Landing : KDS300LCI-seven segment Red indicator and round surface mounted buttons
FEATURES : (a) Direction and position indicator in car . (b) Emergency Alarm. (c) Facia Plate (d ) 2 phase fire man drive (e) Two way hands free press & speak intercom (f) Full height Infra red safety curtains with criss cross beams (g) Pit ladder (h) Emergency light with rechargeable battery (j) Adjustable guide shoes (k) Micro movement LED based buttons (l) + 10% To - 10 % volt fluct with stand capacity (m) Mirror on rear side (half height) (n) Over speed governer (o) Load weighing device (p) Automatic phase reversal (q) Manual rescue Operation. (r) Pressure limiter in doors (s) Car door lock (t) Automatic rescue device/automatic landing device to be operated with maintenance free batteries for safe landing as specified.
Design, Supply, installation, testing and commissionning of 08 passengers Gearless lifts with machine room to serve Basement, Ground+4th upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, full collective simplex controlled operation, centre opening power doors with door drive (Electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue device system and built in intercom system without hand set & infra red curtain, all as specified herein under. Note: 1. The Lifts shall be installed by the original eqpt manufacturer only. 2. The Lifts shall be tested by IEM at the time of installation in the attendance of manufacturer. 3. The contractor will carry out telephone wiring from all the lifts to the control room as suggested by the GE/Engr-in-charge and installed telephone with any additional exchage/communication equipment if required. This control room should be able to communicate with all the lifts through telephone 24 hrs unintrupted necessary UPS etc will be provided by the contractor without any additional cost to the department. 4. The lift well is ready for installations of the lift ,drgs of lift well shall be provided by the deptt and designing of the lift shall be as per existing lift well. 5. The contractor shall clear all the debris/mud/dewatering of already constructed lift well before installation of lift and rate for the same shall be deemed to be included in quoted item rate.
(i) Type and capacity of Lift : 08 Passengers.-544kgs (ii) Speed: 1.0 m/sec with single speed motor (iii) Type of Drive : AC variable voltage & variable frequency (iv) Machine room : Located above the hoist way (v) Travel - 21.750 Mtrs (Approx) (vi)Serving : Basement,ground to 4th Floor( Floor designations will be -1,0,1,2,3,4) (vii) No of stop : 6 (viii) Lift to be adjusted in RCC constructed clear hoist way of size 1950mm(W) x 1850mm(D) (After plaster in plum) (ix) Power supply: 415 Volts, 3 phase, AC, 50 Hz (x) Auxiliary : Single phase 220 volt 50 C/s AC (xi) Car size (inside): 1100mm (W)x 1300mm(D)x2200mm(H) (xii) Pit depth : 1600 mm (xiii) Head room : 5000 mm (xiv) Car enclosure: Car ceiling : SS hairline finish ceiling with fan(CT002), Car panels : SS hairline finish panels, Car Flooring : Aluminium chequered plate flooring, Car Illumination : LED lights (xv) No of entrance -Front opening in all landings (xvi) Car entrance : Centre opening, power doors in stainless steel hairline finish. (xvii) Door safety : Full height infra red curtain (xviii) Landing Entrance: Centre opening, power doors in stainless steel hairline finish for car & landing at all floors (xix) Clear opening : 800mm(W) x 2000mm (high) (xx) Control : Full collective duplex-Adjacent (xxi) Indicators: (a) Car: KDS300 COP-Partial height with seven segment Red indicator and round surface mounted butttons. (b) Landing : KDS300LCI-seven segment Red indicator and round surface mounted buttons
FEATURES : (a) Direction and position indicator in car . (b) Emergency Alarm. (c) Facia Plate (d ) 2 phase fire man drive (e) Two way hands free press & speak intercom (f) Full height Infra red safety curtains with criss cross beams (g) Pit ladder (h) Emergency light with rechargeable battery (j) Adjustable guide shoes (k) Micro movement LED based buttons (l) + 10% To - 10 % volt fluct with stand capacity (m) Mirror on rear side (half height) (n) Over speed governer (o) Load weighing device (p) Automatic phase reversal (q) Manual rescue Operation. (r) Pressure limiter in doors (s) Car door lock (t) Automatic rescue device/automatic landing device to be operated with maintenance free batteries for safe landing as specified.
Design, Supply, installation, testing and commissionning of 26 passengers Gearless lifts without machine room to serve Ground+2nd upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, full collective simplex(1 No) full coolective duplex (Adjacent) -02 Nos controlled operation, side opening power doors with door drive (Electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue device system and built in intercom system without hand set & infra red curtain, all as specified herein under. Note: 1. The Lifts shall be installed by the original eqpt manufacturer only. 2. The Lifts shall be tested by IEM at the time of installation in the attendance of manufacturer. 3. The contractor will carry out telephone wiring from all the lifts to the control room as suggested by the GE/Engr-in-charge and installed telephone with any additional exchage/communication equipment if required. This control room should be able to communicate with all the lifts through telephone 24 hrs unintrupted necessary UPS etc will be provided by the contractor without any additional cost to the department. 4. The lift well is ready for installations of the lift ,drgs of lift well shall be provided by the deptt and designing of the lift shall be as per existing lift well. 5. The contractor shall clear all the debris/mud/dewatering of already constructed lift well before installation of lift and rate for the same shall be deemed to be included in quoted item rate.
(i) Type and capacity of Lift : 26 Passengers.-1768kgs (ii) Speed: 1.0 m/sec with single speed motor (iii) Type of Drive : AC variable voltage & variable frequency (iv) Machine room : Machine room less (v) Travel - 8.70 Mtrs (Approx) (vi)Serving : ground to 2nd Floor( Floor designations will be 0,1,2) (vii) No of stop : 3 (viii) Lift to be adjusted in RCC constructed clear hoist way of size 1950mm(W) x 1850mm(D) (After plaster in plum) (ix) Power supply: 415 Volts, 3 phase, AC, 50 Hz (x) Auxiliary : Single phase 220 volt 50 C/s AC (xi) Car size (inside): 1600mm (W)x 2400mm(D)x2200mm(H) (xii) Pit depth : 1600 mm (xiii) Head room : 5000 mm (xiv) Car enclosure: Car ceiling : SS hairline finish ceiling with fan(CT002), Car panels : SS hairline finish panels, Car Flooring : Aluminium chequered plate flooring, Car Illumination : LED lights (xv) No of entrance -Front opening in all landings (xvi) Car Entrance- Side opening, power doors in stainless steel hairline finish. (xvii) Door safety : Full height infra red curtain (xviii) Landing Entrance: Side opening, power doors in stainless steel hairline finish for car & landing at all floors. (xix) Clear opening : 1000mm(W) x 2000mm (high) (xx) Control : Full collective duplex (adjacent) -02 Nos (xxi) Indicators: (a) Car: KDS300 COP-Partial height with seven segment Red indicator and round surface mounted buttons. (b) Landing : KDS300LCI-seven segment Red indicator and round surface mounted buttons
FEATURES : (a) Direction and position indicator in car . (b) Emergency Alarm. (c) Facia Plate (d ) 2 phase fire man drive (e) Two way hands free press & speak intercom (f) Full height Infra red safety curtains with criss cross beams (g) Pit ladder (h) Emergency light with rechargeable battery (j) Adjustable guide shoes (k) Micro movement LED based buttons (l) + 10% To - 10 % volt fluct with stand capacity (m) Mirror on rear side (half height) (n) Over speed governer (o) Load weighing device (p) Automatic phase reversal (q) Manual rescue Operation. (r) Pressure limiter in doors (s) Car door lock (t) Automatic rescue device/automatic landing device to be operated with maintenance free batteries for safe landing as specified.
Design, Supply, installation, testing and commissionning of 26 passengers Gearless lifts with machine room to serve Ground+2nd upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, full collective simplex(1 No) full coolective duplex (Adjacent) -02 Nos controlled operation, side opening power doors with door drive (Electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue device system and built in intercom system without hand set & infra red curtain, all as specified herein under Note: 1. The Lifts shall be installed by the original eqpt manufacturer only. 2. The Lifts shall be tested by IEM at the time of installation in the attendance of manufacturer. 3. The contractor will carry out telephone wiring from all the lifts to the control room as suggested by the GE/Engr-in-charge and installed telephone with any additional exchage/communication equipment if required. This control room should be able to communicate with all the lifts through telephone 24 hrs unintrupted necessary UPS etc will be provided by the contractor without any additional cost to the department. 4. The lift well is ready for installations of the lift ,drgs of lift well shall be provided by the deptt and designing of the lift shall be as per existing lift well. 5. The contractor shall clear all the debris/mud/dewatering of already constructed lift well before installation of lift and rate for the same shall be deemed to be included in quoted item rate.
(i) Type and capacity of Lift : 26 Passengers.-1768kgs (ii) Speed: 1.0 m/sec with single speed motor (iii) Type of Drive : AC variable voltage & variable frequency (iv) Machine room : Located above the hoist way (v) Travel - 8.70 Mtrs (Approx) (vi)Serving : ground to 2nd Floor( Floor designations will be 0,1,2) (vii) No of stop : 3 (viii) Lift to be adjusted in RCC constructed clear hoist way ofsize 2250mm(W) x 3050mm(D) (After plaster in plum) (ix) Power supply: 415 Volts, 3 phase, AC, 50 Hz (x) Auxiliary : Single phase 220 volt 50 C/s AC (xi) Car size (inside): 1600mm (W)x 2400mm(D)x2200mm(H) (xii) Pit depth : 1600 mm (xiii) Head room : 5000 mm (xiv) Car enclosure: Car ceiling : SS hairline finish ceiling with fan(CT002), Car panels : SS hairline finish panels, Car Flooring : Aluminium chequered plate flooring, Car Illumination : LED lights (xv) No of entrance -Front opening in all landings (xvi) Car Entrance- Side opening, power doors in stainless steel hairline finish. (xvii) Door safety : Full height infra red curtain. (xviii) Landing Entrance: Side opening, power doors in stainless steel hairline finish for car & landing at all floors. (xix) Clear opening : 1000mm(W) x 2000mm (high). (xx) Control : Full collective Simplex (adjacent) -01 No (xxi) Indicators: (a) Car: KDS300 COP-Partial height with seven segment Red indicator and round surface mounted buttons. (b) Landing : KDS300LCI-seven segment Red indicator and round surface mounted buttons
FEATURES : (a) Direction and position indicator in car . (b) Emergency Alarm. (c) Facia Plate (d ) 2 phase fire man drive (e) Two way hands free press & speak intercom (f) Full height Infra red safety curtains with criss cross beams (g) Pit ladder (h) Emergency light with rechargeable battery (j) Adjustable guide shoes (k) Micro movement LED based buttons (l) + 10% To - 10 % volt fluct with stand capacity (m) Mirror on rear side (half height) (n) Over speed governer (o) Load weighing device (p) Automatic phase reversal (q) Manual rescue Operation. (r) Pressure limiter in doors (s) Car door lock (t) Automatic rescue device/automatic landing device to be operated with maintenance free batteries for safe landing as specified.
Design, Supply, installation, testing and commissionning of 20 passengers Gearless lifts with machine room to serve Ground+4 th upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, full collective duplex (Adjacent) controlled operation, side opening power doors with door drive (Electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue device system and built in intercom system without hand set & infra red curtain, all as specified herein under. Note: 1. The Lifts shall be installed by the original eqpt manufacturer only. 2. The Lifts shall be tested by IEM at the time of installation in the attendance of manufacturer. 3. The contractor will carry out telephone wiring from all the lifts to the control room as suggested by the GE/Engr-in-charge and installed telephone with any additional exchage/communication equipment if required. This control room should be able to communicate with all the lifts through telephone 24 hrs unintrupted necessary UPS etc will be provided by the contractor without any additional cost to the department. 4. The lift well is ready for installations of the lift ,drgs of lift well shall be provided by the deptt and designing of the lift shall be as per existing lift well. 5. The contractor shall clear all the debris/mud/dewatering of already constructed lift well before installation of lift and rate for the same shall be deemed to be included in quoted item rate.
(i) Type and capacity of Lift : 20 Passengers.-1360kgs (ii) Speed: 1.0 m/sec with single speed motor (iii) Type of Drive : AC variable voltage & variable frequency (iv) Machine room : Located above the hoist way (v) Travel - 17.35 Mtrs (Approx) (vi)Serving : ground to 4th Floor( Floor designations will be 0,1,2,3,4) (vii) No of stop : 5 (viii) Lift to be adjusted in RCC constructed clear hoist way ofsize 2250mm(W) x 3050mm(D) (After plaster in plum) (ix) Power supply: 415 Volts, 3 phase, AC, 50 Hz (x) Auxiliary : Single phase 220 volt 50 C/s AC (xi) Car size (inside): 1300mm (W)x 2400mm(D)x2200mm(H) (xii) Pit depth : 1600 mm (xiii) Head room : 5000 mm (xiv) Car enclosure: Car ceiling : SS hairline finish ceiling with fan(CT002), Car panels : SS hairline finish panels, Car Flooring : Aluminium chequered plate flooring, Car Illumination : LED lights (xv) No of entrance -Front opening in all landings (xvi) Car Entrance- Side opening, power doors in stainless steel hairline finish. (xvii) Door safety : Full height infra red curtain (xviii) Landing Entrance: Side opening, power doors in stainless steel hairline finish for car & landing at all floors. (xix) Clear opening : 1000mm(W) x 2000mm (high) (xx) Control : Full collective group control (adjacent)- 04 nos. (xxi) Indicators: (a) Car: KDS300 COP-Partial height with seven segment Red indicator and round surface mounted buttons. (b) Landing : KDS300LCI-seven segment Red indicator and round surface mounted buttons
FEATURES : (a) Direction and position indicator in car . (b) Emergency Alarm. (c) Facia Plate (d ) 2 phase fire man drive (e) Two way hands free press & speak intercom (f) Full height Infra red safety curtains with criss cross beams (g) Pit ladder (h) Emergency light with rechargeable battery (j) Adjustable guide shoes (k) Micro movement LED based buttons (l) + 10% To - 10 % volt fluct with stand capacity (m) Mirror on rear side (half height) (n) Over speed governer (o) Load weighing device (p) Automatic phase reversal (q) Manual rescue Operation. (r) Pressure limiter in doors (s) Car door lock (t) Automatic rescue device/automatic landing device to be operated with maintenance free batteries for safe landing as specified.
Design, Supply, installation, testing and commissionning of 26 passengers Gearless lifts with machine room to serve Basement, Ground+4th upper floors with AC variable voltage & variable frequency (VVVF) drive complete with all standard accessories, full collective duplex (Adjacent) controlled operation, side opening power doors with door drive (Electric motor driven mechanism) sliding stainless steel doors, Automatic Rescue device system and built in intercom system without hand set & infra red curtain, all as specified herein under. Note: 1. The Lifts shall be installed by the original eqpt manufacturer only. 2. The Lifts shall be tested by IEM at the time of installation in the attendance of manufacturer. 3. The contractor will carry out telephone wiring from all the lifts to the control room as suggested by the GE/Engr-in-charge and installed telephone with any additional exchage/communication equipment if required. This control room should be able to communicate with all the lifts through telephone 24 hrs unintrupted necessary UPS etc will be provided by the contractor without any additional cost to the department. 4. The lift well is ready for installations of the lift ,drgs of lift well shall be provided by the deptt and designing of the lift shall be as per existing lift well. 5. The contractor shall clear all the debris/mud/dewatering of already constructed lift well before installation of lift and rate for the same shall be deemed to be included in quoted item rate.
(i) Type and capacity of Lift : 26 Passengers.-1768kgs (ii) Speed: 1.0 m/sec with single speed motor (iii) Type of Drive : AC variable voltage & variable frequency (iv) Machine room : Located above the hoist way (v) Travel -21.750 Mtrs (Approx) (vi)Serving : Basement, ground to 4th Floor( Floor designations will be-1, 0,1,2,3,4) (vii) No of stop : 6 (viii) Lift to be adjusted in RCC constructed clear hoist way ofsize 2250mm(W) x 3050mm(D) (After plaster in plum) (ix) Power supply: 415 Volts, 3 phase, AC, 50 Hz (x) Auxiliary : Single phase 220 volt 50 C/s AC (xi) Car size (inside): 1600mm (W)x 2400mm(D)x2200mm(H) (xii) Pit depth : 1600 mm (xiii) Head room : 5000 mm (xiv) Car enclosure: Car ceiling : SS hairline finish ceiling with fan(CT002), Car panels : SS hairline finish panels, Car Flooring : Aluminium chequered plate flooring, Car Illumination : LED lights (xv) No of entrance -Front opening in all landings (xvi) Car Entrance- Side opening, power doors in stainless steel hairline finish. (xvii) Door safety : Full height infra red curtain (xviii) Landing Entrance: Side opening, power doors in stainless steel hairline finish for car & landing at all floors. (xix) Clear opening : 1000mm(W) x 2000mm (high) (xx) Control : Full collective group control (adjacent)- 04 nos. (xxi) Indicators: (a) Car: KDS300 COP-Partial height with seven segment Red indicator and round surface mounted buttons. (b) Landing : KDS300LCI-seven segment Red indicator and round surface mounted buttons
FEATURES : (a) Direction and position indicator in car . (b) Emergency Alarm. (c) Facia Plate (d ) 2 phase fire man drive (e) Two way hands free press & speak intercom (f) Full height Infra red safety curtains with criss cross beams (g) Pit ladder (h) Emergency light with rechargeable battery (j) Adjustable guide shoes (k) Micro movement LED based buttons (l) + 10% To - 10 % volt fluct with stand capacity (m) Mirror on rear side (half height) (n) Over speed governer (o) Load weighing device (p) Automatic phase reversal (q) Manual rescue Operation. (r) Pressure limiter in doors (s) Car door lock (t) Automatic rescue device/automatic landing device to be operated with maintenance free batteries for safe landing as specified.
Point wiring with 1.5sqmm PVC insulated FRLS unsheather copper conductor single core multi strand flexible cable and 1.5 sqmm PVC insulated unsheathed copper conductor single core cable (green colour) as earth lead in, surface type, drawing in and including steel conduit 25 mm dia, having wall thickness not less than 2 mm for one light/ fan point/bell point controlled by one switch , complete all as specified and directed by Engr-in-Charge.
All as per Item No. 07 above, but for one socket outlet 3 pins 5 amps controlled by one switch on independent board, complete all as specified and directed
Modular switch, one way 6 Amp, 240 volts, Complete all as specified and directed.
Modular socket, 6A 2/3 Pin combined 2 module ,230 V, complete all as specified and directed.
Metal flush box,1 module, complete all as specified and directed.
Metal flush box, 3 module, complete all as specified and directed.
White cover plate with frame, 1 module, complete all as specified and directed.
White cover plate with frame, 3 module, complete all as specified and directed.
Sheet Metal enclosures MCB distribution board single pole and neutral 240 volts 4 way with IP-43 IK-09 protection double door complete with 200 amps size bus bar and neutral link, Complete all as specified and directed.
Sheet Metal enclosures MCB distribution board single pole and neutral 240 volts 2 way with IP-43 IK-09 protection double door complete with 200 amps size bus bar and neutral link, Complete all as specified and directed.
C curve MCB SPN 240 Volts any rating from 32 to 63 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and as directed by Engr-in-Charge.
C curve MCB SP 240 Volts any rating from 5 to 32 amps, with rupturing capacity 10 KA, including providing thimble for out going cables, complete all as specified and as directed by Engr-in-Charge.
Bulk head light fitting ENDURA RUGBY Energy saving new generation 10 W LED IP 65 bulkhead luminaire with opal diffuser including connecting electricity to ceiling rose using 3 core PVC insulated overall sheathed stranded copper conductor of size 0.75 sqmm , complete all as specified and as directed by Engr-in-Charge. Make Havells/CG/Bajaj/Surya/Philips.
Ceiling rose, 3 Phase PVC/polycarbonate isolated body , complete all as specified and as directed by Engr-in-Charge.
Sub main wiring complete with two runs of 6 Sqmm single core FRLS PVC insulated unsheathed cable 1100 volts grade, multistranded with copper conductor fire retardant drawn thorugh and including 20 mm dia size steel conduit having wall thickness not less than 2mm, including band accessories surface in walls, roofs, etc with and incl one run of 6 sqmm multi stranded copper conductor single core PVC insulated unshetahed cable 1100 volts grade FRLS for earth continuity conductor, complete all as specified and directed by Engr-in-Charge. Note:- 2 runs of 6 Sqmm (2x6sqmm ) ,one run of 6 Sqmm (1x6 sqmm ) cable and one metre of conduit will be measured as one unit.
N K BUILDERS
Escon Elevators Pvt Ltd
Varindera Constructions Limited
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .