Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹17.5 L+₹1.1 L (6.98%)Rejected-Finance | L2 | Rejected-Finance Other than lowest quoted. | |
| 3 | L3₹19.8 L+₹3.4 L (20.6%)Rejected-Finance SHANTI KUNJ CHESIRE HOME ROAD BARIATU RANCHI 834009 JHARKHAND | RANCHI | JHARKHAND | 834009 | L3 | Rejected-Finance Other than lowest quoted. | |
| 4 | L4₹20.2 L+₹3.8 L (23.4%)Rejected-AOC | L4 | Rejected-AOC Other than lowest bidder | |
| 5 | Rejected-Technical VILL MAHULLYA PS PATAN NAWA KHAS DIST PALAMU JHARKHAND 822123 | NAWA KHAS | PALAMU | JHARKHAND | 822123 | - | Rejected-Technical Not enlisted in requisite cat as per NIT |
| Sl No | Description | Qty | Unit | M/S Sahib N Sahiba Enterprises L4 | BHARATI ENTERPRISES L3 | M/S RANKWAR CONSTRUCTION L1 | JAYSHREE ENTERPRISES L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as specified and directed. | 15 | Cum | 440 ₹6,600 | 450 ₹6,750 | 400 ₹6,000 | 200 ₹3,000 Lowest |
| 2.00 | Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) , complete all as specified and directed. | 31.5 | Cum | 550 ₹17,325 | 500 ₹15,750 | 420 ₹13,230 | 150 ₹4,725 Lowest |
| 3.00 | Dismantling of Stone sett paving laid dry and dry pointing of any description or thickness | 52.5 | 10 Sqm | 630 ₹33,075 | 300 ₹15,750 | 70 ₹3,675 Lowest | 100 ₹5,250 |
| 4.00 | M&L PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in benching, coping, kerbs etc | 1.5 | Cum | 5,500 ₹8,250 | 5,000 ₹7,500 | 350 ₹525 Lowest | 4,500 ₹6,750 |
| 5.00 | M&L for 100 mm thich PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed | 300 | Sqm | 390 ₹1,17,000 | 425 ₹1,27,500 | 120 ₹36,000 Lowest | 380 ₹1,14,000 |
| 6.00 | M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand , complete all as specified and directed. | 525 | Sqm | 830 ₹4,35,750 | 800 ₹4,20,000 | 450 ₹2,36,250 Lowest | 700 ₹3,67,500 |
| 7.00 | Material & labour for chequered cement concrete tiles factory made pre polished glossy finished 30cmx30cmx20-25mm thick set, jointed and pointed in neat cement slurry in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified & directed. | 150 | Sqm | 690 ₹1,03,500 Lowest | 745 ₹1,11,750 | 950 ₹1,42,500 | 750 ₹1,12,500 |
| 8.00 | M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 complete all as specified and directed. | 12 | Cum | 4,900 ₹58,800 | 5,100 ₹61,200 | 6,000 ₹72,000 | 4,800 ₹57,600 Lowest |
| 9.00 | Description all as per ser item No 8 above, but except bricks complete all as specified and directed. | 3 | Cum | 650 ₹1,950 Lowest | 1,500 ₹4,500 | 4,000 ₹12,000 | 1,500 ₹4,500 |
| 10.00 | Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete all as specified and directed. | 750 | Sqm | 40 ₹30,000 | 20 ₹15,000 Lowest | 40 ₹30,000 | 25 ₹18,750 |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
23 Feb 2026, 6:00 pmClosed
Shri Manjul Kumar Tripathi, GE
Garrison Engineer Ranchi, 7th Club Road Ranchi, PIN-834001
REPAIR MAINT INCL PLASTERING AND PAINTING OF COMPOUNDS WALLS AT KHOJATOLI AREA AND REPAIR MAINT TO LT PANELS STARTOR, PUMP CONTROL PANELS AT PUMP HOUSE NAMKUM AND LPH AREA ENGR LINE AND RO FLT UNDER GE RANCHI
2026_MES_750973_1
8200/1674/E8
Open Tender
Civil Works
Item Rate
180 days
GE Ranchi
Class E Cat a (i) b (i)
7 documents required · 7 mandatory
₹500
GE Ranchi
₹48,000
Yes
15 Apr 2026
2 Feb 2026
2 Mar 2026
2 Feb 2026
23 Feb 2026
16 Feb 2026
Demolition of brick work build in cement mortar including all quoins, arches, pillars, complete all as specified and directed.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) , complete all as specified and directed.
Dismantling of Stone sett paving laid dry and dry pointing of any description or thickness
M&L PCC 1:2:4 type B1 using 20 mm grade stone aggregate as in benching, coping, kerbs etc
M&L for 100 mm thich PCC 1:4:8 type D-2 using 40mm graded stone aggregate as in sub base of floor complete all as specified and directed
M&L Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc.,of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand , complete all as specified and directed.
Material & labour for chequered cement concrete tiles factory made pre polished glossy finished 30cmx30cmx20-25mm thick set, jointed and pointed in neat cement slurry in floor over and including 15mm thick screed bed in CM (1:6) complete all as specified & directed.
M&L brick work with sub class 'B' brick straight or curved on plan exc 6m means radius build in cement mortar 1:6 complete all as specified and directed.
Description all as per ser item No 8 above, but except bricks complete all as specified and directed.
Taking down cement plaster on wall of any description incl racking out joints hacking for key and scrubbing down with water complete all as specified and directed.
M&L 15mm thick rendering on fair faces of bk /concrete surfaces in cm (1:6), finished even and smooth (Without using extra cement ) complete all as specified and directed.
M&L three coat of cement paint on newly prepared surfaces on wall , etc complete all as specified and directed.
M&L two coat of cement paint on Complete removal of existing old surfaces on wall , etc complete all as specified and directed.
M&L finishing walls on newly prepared surfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
M&L finishing walls on Complete removal of old prepared surfaces with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) complete all as specified and directed.
Taking out defective submersible pump set installed at 200-400 feet depth including disconnecting electric connections, removing submersible cable, GI column pipe, safety rope, and all accessories using tripod/winch/chain pulley/Hydra arrangement, servicing and repair of submersible pump capacity upto 15 HP including dismantling of pump and motor, cleaning of impellers, shaft alignment, greasing, replacement of gasket set, gland packing, minor hardware, and reassembly and transporting the defective borewell to workshop. after repair lowering and re-installation of repaired submersible pump set back to 200–400 feet depth including lowering of GI pipe column/PVC pipe, submersible cable, clamp arrangement and reconnection of starter suitable for the rating of existing submersible pump, including wiring connections. After installation, the system shall be tested including megger test of cable and motor, running and load current check, leak testing, discharge verification and handing over the system in fully satisfactory operational condition complete as directed by Engineer-in-Charge. Note: (a) Unit rate quoted shall deemed to include only labour for taking up & lowering the submersible pump from bore well along with delivery pipe complete (b) Repairs/rewinding of submersible pump shall be measured & paid for separately under relevant items. (c) Replacement of colummn pipe will be measured and paid for separately as supply only, under relevants items. (d) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing, metal filling, machining and transportation from site to work shop and back are deemed to be included in rate quoted
M&L for rewinding the Submersible pump Motor with PVC insulated, super enamelled copper conductor with ‘F’ class heavy grade insulation weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly including taking down old existing copper winding complete all as specified and directed for Submersible pump motor of following capacity :-
Description all as per ser item No 17 here-in-before but of submersible Motor above 5 HP and upto and including 5 HP.
Description all as per ser item No 17 here-in-before but of submersible Motor above 5 HP and upto 10 HP.
Supply, installation, commissioning and testing of submersible pump & motor set, electric driven, 415V, TP suitable for 200 mm dia borewell (casing pipe size 200 mm) supplied and installed complete 7.5 HP, complete all as specified and directed.
Supply and fix 1HP booster pump single phase maximum head 42 meter discharge section and delivery 25mm copper winding maximum recommended pressure 3.8 bar complete all as specified and as directed.
M & L in replacement for GI pipe heavy grade 50mm dia, cut into 3.0 mtr length including providing of threading on both sides and lowering into the existing bore well along with existing GI pipe for increasing the length of the borewell pipe as in repairs complete all as specified and directed.
Supply and fixing in replacement and water proof submersible cable 3 core copper conductor, PVC insulated 1100 volts grade 2.5 Sqmm protected by means of metal clip alongwith the pump body and connected to pump motor through water tight sealing joints including taking out old unserviceable submersible cable complete all as specified and as directed.
Dismantling and taking out the centrifugal pumping set with motor from the existing foundation for carring necessary repair/ servicing by replacing the unservicable parts including overhauling the pump set, renewal of gasket to pump, suction and delivery lines, gland packing, greasing nuts, bolts and washers, re-connecting up of the electric / water connections, including fixing of new coupling (CI/rubber) as per existing all as required at site of work of capacity upto 25 HP, including re-fixing at same location including aligning and commissioning complete all as specified and directed. Notes:- (i) Expendable stores like cotton waste / cleaning materials, lubricants, gland packing etc., and transportation from site to work shop and back are deemed to be included in unit rate quoted. (ii) Labour element is deemed to be included in unit rate quoted.
M&L Dismantling and strip opening the motor completely including disconnecting the cable connections and coupling of the motor removing the starter and rotor units, bearings complete servicing the motor assembly including cleaning the carbon deposits with carbon tetra chloride, greasing the bearings etc., heat varnishing the motor windings by applying varnish and keeping the windings into the hot air oven till the moisture evaporates complete at authorized workshop including transportation and refit the same after repairs and re-connecting up of the electric connections including testing and commissioning complete all as specified and directed for the following capacities:-
Description all as per item No 23 for Induction Motor 10 to 20 HP capacity.
Description all as per item No 23 for Induction Motor upto 10 HP capacity.
M&L cutting and taking out the unserviceable / burnt out copper winding from the electric motor, preparation of the surface and rewinding the same with super enamelled copper conductor with ‘F’ class heavy grade insulation, weight and turns to achieve its full efficiency including tying the winding and connecting the coils and brining the connections as that of existing one including applying insulating varnish, heating and backing the windings thoroughly with necessary insulating materials complete all as specified for the capacities upto 25 HP motor
Supply and fix Ball bearing in replacement for electric motor of capacity 10 to 25 HP, 3 Phase as per existing make and model complete all as specified and directed. Make : Hindustan Brown Breware or equivalent as approved by GE
Supply and fix Ball bearing in replacement for electric motor of capacity upto 10 HP, 3 Phase as per existing make and model complete all as specified and directed. Make : Hindustan Brown Breware or equivalent as approved by GE
Supply and fixing in replacement of power contactor type ML-3 complete all as specified and directed.
Supply and fixing in replacement of power contactor type ML-1 complete all as specified and directed.
Taking down MCCB by disconnecting all connections very carefully of any size and capacity and complete all as specified and directed at site by Engr-in-charge.
Supply and fix in replacement MCCB TPN 415 volts 250 Amps 50 Hz Thermal magnetic adjustable type, with breaking capacity 36 KA complete all as specified and directed at site. Make : legrand/Schenider/siemens
Supply and fix in replacement MCCB TPN 415 volts 125 Amps 50 Hz Adjustable type, with breaking capacity 25 KA complete all as specified and directed at site. Make : legrand/Schenider/siemens
Taking down/disconnecting the existing Star Delta starter of Centrifugal / submersible pump from motor control panels of various pump houses and replace with new Star delta starter of capacity 10 HP to 25 HP, three phase, including making electric connection, complete all as specified and directed. Make L&T/Schneider/ABB
S&F in replacement 3 phase 415 Volts, submersible pump controller MU-G6 (5 HP - 7.5 HP DOL) or 3 seat enclosure with over load, short circuit, under current, unbalance, phase reversal, phase loss,locked rotar, eath fault, stall ,CB failure with fault record with date and time, having feature of fail safe operation, and over load characterstic rating 14 Amps, relay range 9 to 14 Amps, including connecting up of incoming and outgoing connections and testing commissioning, including removing the existing unserviceable one complete all as specified and directed.
M&L for spray painting (two coat of synthetic enamel paint) on centrifugal pump & motor of any capacity rating upto 10 HP, scratching the rusted and suction/delivery pipe line including NRV and sluice valve, MS Base chanel complete all as specified and as directed.
M &L for GI Earthing complete with GI earth plate electrode 60cm x 60cm x6 mm buried directly in ground verticvally to size of earth pit not less than 0.90x 0.90 x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32 x 6 mm, 7.5 mtr long (Min) by means of brazing nuts, bolts, check nuts, & washers ,testing of completion (drawn in earth strip protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I filling with charcoal dust , and common salt , including necessary excavation and earth work in any type of soil ,perforated watering pipeof size 15 mm dia,funnel with wire mesh,earth strip protection pipe light grade PCC chamber 1:3:6 type C1 (for even finish on both the faces) and RCC cover 1:2:4 Type B1,450 x450 x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc all as specified and directed by EIC Note : (i) 7.5 RM GI earth wire deemed to be included in quoted rates beyond 7.5 RM wire shall be measured and paid separately. (ii) Earth resistance of earth pit should be not more than 02 Ohms on testing after completion if the desired earth resistance is not obtained the earthing will be redone at no extra cost. (iii) Rate quoted by the tenderer is deemed to included salt & Charcoal upto & above 450 mm (Min) top of GI Plate.
S&F GI earth strip (32x6) mm strip with and including necessary clamps, nut bolts laid in ground complete all as specified and as directed.
S&F of steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia (Multi wire stainless steel) for holding of submersible pump motor set all as directed by Engineer-in-Charge.
S&F monoblock pump (tullu pump) set 0.5 HP fixing the same on its position/new position electrically operated 240 volts, 50 Hz fixed to 15/20 mm dia or 20/25mm dia including necessary electrical connections and GI fittings including removal of old unsv one complete all as specified and as directed. Make – Kirloskar, KSB, Crompton.
stage.html
html • 0.05 MB
technical_841083.pdf
techsummary_841083.pdf
finance_841083.pdf
BOQ Comparative Chart
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.14 MB
Tender1674.pdf
Tender Documents • 0.69 MB
BOQ_841083.xls
BOQ • 0.86 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .