| 1 | L1₹21.3 LAccepted-AOC H NO 309 REHARI COLONY JAMMU DISTT JAMMU J K 180005 | JAMMU | JAMMU AND KASHMIR | 180005 | ₹21.3 L Quoted ₹22.2 L | L1 | Accepted-AOC Being L1 bidder |
| 2 | L2₹23.8 LRejected-Finance SCHEME NO 07 BLOCK NO 22 FLAT NO 03 NEW GURDASPUR DISTT GURDASPUR PB 143521 | GURDASPUR | PUNJAB | 143521 | ₹23.8 L | L2 | Rejected-Finance Being other than L1 bidder |
| 3 | L3₹24.1 LRejected-Finance S 17 77 1 CHARAN NAGAR COLONY NADESAR VARANASI UTTAR PRADESH PIN 221002 | VARANASI | UTTAR PRADESH | 221002 | ₹24.1 L | L3 | Rejected-Finance Being other than L1 bidder |
| 4 | L4₹24.7 LRejected-Finance | ₹24.7 L | L4 | Rejected-Finance Being other than L1 bidder |
| 5 | L5₹25.1 LRejected-Finance NO 354 2ND CROSS VARADARAJNAGAR VIDYARANYAPURA POST BANGALORE 5600 097 | 5600097 | ₹25.1 L | L5 | Rejected-Finance Being other than L1 bidder |
| Sl No | Description | Qty | Unit | Top Mind Industries Pvt Limited L4 | R B TRADERS L7 | PADMA ENTERPRISES L10 | S S BUILDERS L5 | M/S A K ENGINEERS & CO. L1 | HARPAL ENGINEERS AND BUILDERS L2 | SUMEET TRADING CORPORATION L9 | Horizon Construction Company L6 | Charan sales and Service L3 | Sona Enterprises L11 | Ms Salaria Builders L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge. | 1,530 | Point | 10 ₹15,300 | 10 ₹15,300 | 20 ₹30,600 | 1 ₹1,530 | 20 ₹30,600 | 20 ₹30,600 | 10 ₹15,300 | 5 ₹7,650 | 10 ₹15,300 | 1 ₹1,530 | 3 ₹4,590 |
| 2.00Point wiring complete with 1.5 Sq.mm nominal area of copper conductor (FRLSH) multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed multistranded 1.5 Sqmm copper conductor (FRLSH) cable as continuous earth lead all as specified and directed for the followings:- | ||||||||||||||
| 2.01 | One light/exhaust fan point controlled by one way switch | 950 | Per Point | 450 ₹4.3 L | 550 ₹5.2 L | 300 ₹2.9 L | 620 ₹5.9 L | 610 ₹5.8 L | 550 ₹5.2 L | 450 ₹4.3 L | 375 ₹3.6 L | 500 ₹4.8 L | 720 ₹6.8 L | 475 ₹4.5 L |
| 2.02 | One bell point controlled by one bell push on independent board. | 20 | Per Point | 450 ₹9,000 | 550 ₹11,000 | 325 ₹6,500 | 620 ₹12,400 | 610 ₹12,200 | 550 ₹11,000 | 450 ₹9,000 | 400 ₹8,000 | 500 ₹10,000 | 720 ₹14,400 | 495 ₹9,900 |
| 2.03 | One 3 pin switch socket combination 5 Amp on independent board complete all as specified and directed. | 240 | Per Point | 450 ₹1.1 L | 550 ₹1.3 L | 280 ₹67,200 | 620 ₹1.5 L | 610 ₹1.5 L | 550 ₹1.3 L | 450 ₹1.1 L | 350 ₹84,000 | 500 ₹1.2 L | 720 ₹1.7 L | 475 ₹1.1 L |
| 2.04 | One 3 pin socket out let 5 Amp on the same board with other switches complete all as specified and directed. | 80 | Per Point | 450 ₹36,000 | 150 ₹12,000 | 325 ₹26,000 | 620 ₹49,600 | 610 ₹48,800 | 250 ₹20,000 | 200 ₹16,000 | 100 ₹8,000 | 500 ₹40,000 | 630 ₹50,400 | 220 ₹17,600 |
| 3.00 | All as item No 2 above, but using cables 2.5 Sq mm size for 15 Amps socket point. | 240 | Per Point | 750 ₹1.8 L | 800 ₹1.9 L | 350 ₹84,000 | 750 ₹1.8 L | 610 ₹1.5 L | 350 ₹84,000 | 670 ₹1.6 L | 500 ₹1.2 L | 500 ₹1.2 L | 1,260 ₹3.0 L | 650 ₹1.6 L |
| 4.00 | Supply and replacement of lamp holder insulated body with back plate. | 150 | Each | 60 ₹9,000 | 40 ₹6,000 | 100 ₹15,000 | 40 ₹6,000 | 45 ₹6,750 | 45 ₹6,750 | 30 ₹4,500 | 50 ₹7,500 | 50 ₹7,500 | 27 ₹4,050 | 55 ₹8,250 |
| 5.00 | Supply and fix of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed. | 1,030 | Each | 50 ₹51,500 | 22 ₹22,660 | 40 ₹41,200 | 30 ₹30,900 | 25 ₹25,750 | 20 ₹20,600 | 30 ₹30,900 | 70 ₹72,100 | 24 ₹24,720 | 15 ₹15,450 | 22 ₹22,660 |
| 6.00 | Supply and fix of switch Socket combination 5 pin 5 & 15 Amps flush type.230 volts complete all as directed. | 240 | Each | 200 ₹48,000 | 170 ₹40,800 | 300 ₹72,000 | 150 ₹36,000 | 90 ₹21,600 | 175 ₹42,000 | 220 ₹52,800 | 200 ₹48,000 | 170 ₹40,800 | 100 ₹24,000 | 210 ₹50,400 |
Updated dates
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
30 Mar 2026, 6:00 pmClosed
GE 865 EWS
GE 865 EWS PIN-913865 c/o 56 APO
REPAIR REPLACEMENT OF INTERNAL ELECTRIFICATION AND ALLIED WORKS AT SECTOR B UNDER AGE EM II OF GE 865 EWS
2026_MES_754499_1
865/EWS(NIT-14)/2026-27
Open Tender
Civil Works
180 days
GE 865 EWS Leh
Please refer Tender Documents
9 documents required · 9 mandatory
₹500
GE 865 EWS
₹83,000
Yes
18 May 2026
28 Feb 2026
2 Apr 2026
28 Feb 2026
30 Mar 2026
14 Mar 2026
Taking down carefully copper/aluminium point wiring (light, fan, socket and power point) complete fittings such as switches, ceiling rose, regulators, socket etc and removing material from site and making good disturbed surfaces of walls, floors/ceiling to match the existing surface all as spfd and directed by Engr-in-Charge.
Point wiring complete with 1.5 Sq.mm nominal area of copper conductor (FRLSH) multi stranded PVC insulated and unsheathed 1100 volts cable drawn through & including PVC Casing & caping with standard accessories such as elbows, tees, junctions etc. and PVC moulded terminal box with top cover of including PVC insulated unsheathed multistranded 1.5 Sqmm copper conductor (FRLSH) cable as continuous earth lead all as specified and directed for the followings:-
One light/exhaust fan point controlled by one way switch
One bell point controlled by one bell push on independent board.
One 3 pin switch socket combination 5 Amp on independent board complete all as specified and directed.
One 3 pin socket out let 5 Amp on the same board with other switches complete all as specified and directed.
All as item No 2 above, but using cables 2.5 Sq mm size for 15 Amps socket point.
Supply and replacement of lamp holder insulated body with back plate.
Supply and fix of Switch piano flush button single pole 6 Amps 230 volts one way complete all as directed.
Supply and fix of switch Socket combination 5 pin 5 & 15 Amps flush type.230 volts complete all as directed.
Supply and fix of switch Socket combination flush type 3/5 pin 5/6 Amps 230 volts complete all as directed.
Supply and fix of Ceiling rose, surface Bakelite three terminals complete all as directed.
Supply and fix of bell push single pole 230 volt complete all as directed.
M & L in repair for bell ding-dong single pole complete all as directed.
Supply and fix in replacement of Modular Switch 1 way 6 Amps 230 volts, 1 Module complete all as directed.
Supply and fix in replacement of Modular switch Socket combination out let 5 pin 6 Amps flush type.230 volts complete all as directed.
Supply and fix in replacement of Modular switch Socket combination out let multi purpose 5 pin 6 Amps and 16 Amps 230 volts complete all as directed.
Supply and fix in replacement of modular white cover plate with frame of 3 Module suitable for 3 pin 6 Amps and 16 Amps 230 volts complete all as directed.
Supply and fix in replacement of modular white cover plate with frame of 6 Module suitable for 5 pin 6 Amps and 16Amps 230 volts complete all as directed.
Supply and fix in replacement of modular metal flush box of 03 Module suitable for 5 pin 6 Amps and 16 Amps 230 volts complete all as directed.
Supply and fix in replacement of modular metal flush box of 06 Module suitable for 5 pin 6 Amps and 16 Amps 230 volts complete all as directed.
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 4 Ways all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volts 8 Ways all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used single pole & neutral 240 Volt 12 Ways all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of sheet metal enclosure for DBs double door when MCB's to be used tripple pole & neutral 440 Volt 4 Ways all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB TPN 63 Amp 440 Volts AC ISI marked all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB SPN 63 Amp 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB SPN 40 Amp 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of MCB SP 6-32 Amps. 240 Volts AC ISI marked all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Air circulator made of sturdy Engineering plastic complete with louvers, shutter, voltage 230 volt, 50 Htz RPM 1200, copper winding of sweep 300mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Air circulator made of sturdy Engineering plastic complete with louvers, shutter, voltage 230 volt, 50 Htz RPM 1200, copper winding of sweep 250mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Air circulator made of sturdy Engineering plastic complete with louvers, shutter, voltage 230 volt, 50 Htz RPM 1200, copper winding of sweep 200mm complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Supply and fix exhaust fan, steel body AC single Phase. 230V of size 380m sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement Supply and fix exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete all as specified and directed by Engr-in-Charge.
Supply and fixing in replacement electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity, 25 Ltrs 5 star rating incl all accessories such as safety valve, thermostat, NRV, connection piece etc complete all as specified and directed by Engr-in-Charge.
M&L for Earthing complete with galvanized steel earth plate electrode 600mm x600mmx 6mm thick buried directly in ground. (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5m below normal ground level, connected to galvanized earth lead wire 4mm dia by GI watering pipe with funnel and wire mesh and 15mm dia protection pipe earth work etc complete all as shown in electrical plate No 5 of MES plate No. 6 and all as specified.
M & L in replacement of submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x4.0 sq. mm + 1x4.0 sq. mm earth wire complete all as specified
M & Lin replacement of submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x6.0 sq. mm + 1x6.0 sq. mm earth wire complete all as specified
M & L in replacement of submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x10.0 sq. mm + 1x10.0 sq. mm earth wire complete all as specified.
Supply and replacement of Havells DBOXx MCB protected Socket plastic base model white with one single pole 20 Amp MCB complete all as specified and directed by Engr-in-Charge.
M & L for submain wiring alongwith earth wire with the following sizes of FRLSH PVC insulated copper conductor, single core cable in surface/recessed as required in PVC casing Caping wire size 2x2.5 sq. mm + 1x2.5 sq. mm earth wire complete all as specified
S & F in replacement of old U/S decorative durable LED batten fitting of 18/20W , 4 feet long with decorative and caps, powder coated CRCA decorative for LED tube of any capacity, 4 feet long (white colour) tube having driver ,connector block etc complete with all accessories prewired and connecting electrically to ceiling rose using PVC insulated and overall sheathed flexible copper conductor cable of size 0.75 Sqmm 3 core all as required at site or directed by Engr in Charge.
S&F in replacement of old U/S LED Mirror light fitting of 9/10 W and type 230 volts box type , with standard specification etc complete withh all accessories pre wired twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge.
S&F in replacement of LED Bulk head luminaire of any capacity 10/11 Watts with all accessories pre wired twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by Engr in Charge.
S&F LED Post top made in cast aluminium spigot housing with decorative opal polycarbonate diffser and IP 65 protection of capacity 25 watt LED white colour including suitable size of GI pipe for fixing of light on post and elecrical connection complete all as specified and directed by Engr in Charge.
S&F 1100 V gde heavy duty cable pvc insulated aluminium conductor served with inner sheathing of pvc tape and over all pvc sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistrand conductor size10.0 sqmm
S&F 1100 V gde heavy duty cable pvc insulated aluminium conductor served with inner sheathing of pvc tape and over all pvc sheathed in service connection suspended by insulating hangers not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat of stranded multistrand conductor size16.0 sqmm
S&F in replacement of old unsv Single core copper conductor of size 1.5 Sqmm (FRLSH) all as specified and directed by Engr in Charge.
S&F in replacement of old unsv Single core copper conductor of size 2.5 Sqmm (FRLSH) all as specified and directed by Engr in Charge.
S&F in replacement of old unsv Single core copper conductor of size 4.0 Sqmm(FRLSH) all as specified and directed by Engr in Charge.
S&F in replacement of old unsv Single core copper conductor of size 6.0 Sqmm(FRLSH) all as specified and directed by Engr in Charge.
S&F in replacement of plug top 3 pin of capacity 5/6 Amp complete all as specified and directed by Engr in Charge.
S&F in replacement of plug top 3 pin of capacity 15/16 Amp complete all as specified and directed by Engr in Charge.
S&F in replacement of LED Driver unit ISI marked suitable for recessed mounting fitting of 24 Watts complete all as specified and directed.
S&F in replacement of LED Driver unit ISI marked suitable for recessed mounting fitting of 36 Watts complete all as specified and directed.
S&F in replacement of LED Aviation light ISI marked suitable for mounting on top of hangers/Chimnies of oil fire incinator etc complete all as specified and directed.
S&F in replacement of old UNSV 2'x2' Recess mounting low depth (white/ warm) LED Luminaires white powder coated CRCA sheet housing LEDs front frame with translucent cover fixed to the housing fixed in front frame 36w LED extruded alluminium heat sink projected in false ceiling .
S&F in replacement of old UNSV 1'x1' Recess mounting low depth white LED Luminaires white powder coated CRCA sheet housing LEDs front frame with translucent cover fixed to the housing fixed in front frame 24w LED extruded alluminium heat sink projected in false ceiling .
S&F in replacement of Old U/S Lamp LED 7/9 Watt, 230 volts 50 Hz AC complete all as specified.
S&F in replacement of Old U/S Lamp LED 5 Watt, 230 volts 50 Hz AC complete all as specified.
M&L replacement of louvers made out of metal sheets suitable for up to 450 mm sweep exhaust fans complete all as specified and directed by Engr in Charge.
S&F in replacement of old unsv Gang box suitable or and including of 2 in 1, 5 Pin 5/15 Amp flush type complete all as specified and directed.
S&F in replacement of old unsv Gang box suitable or and including of 3 Pin 5 Amp flush type universal complete all as specified and directed.
Taking down water heater storage any type & Capacity of any make Vertical / horizontal type after disconnecting the electric/ water connections and dismantling the heating elements /geyser assy and descaling complete with de scaling solutions and replacement of gaskets suitable for resisting 98 degree temp /nut bolts etc all as directed and testing the safety devices and reinstalling at same location complete all as specified and directed by Engr in Charge.
S &F in replacement of water inlet/outlet assy suitable for storage water heater of 25/50 Ltrs capacity having provn of housing thermostate, heating element including providing rubber gaskets and holding nut bolts etc complete all as specified and directed by Engr in Charge.
S &F in replacement of thermostate switch for water storage heater suitable for any type 220/240V 50HzAC temperature range 32 - 88 degree centigde ISI marked complete all as specified and directed by Engr in Charge.
S&F in replacement of Heating elements suitable for water storage heater vertical type of any make 220/240 V AC 1500W and making connections and testing complete all as specified and directed by Engr in Charge.
S&F in replacement of heating elements suitable for water storage heater vertical type of any make 220/240 V AC 2000W and making connections and testing complete all as specified and directed by Engr in Charge.
S&F in replacement of heavy duty PVC connections armored type with brass union ,nut, heat resistance type rubber washer for hot water complete all as specified and directed by Engr in Charge.
S&F in replacement of PVC connections with brass union ,nut, rubber washer for cold water complete all as specified and directed by Engr in Charge.
S&F in replacement of Indicating lamps suitable for storage water heater any type & cap complete all as specified and directed by Engr in Charge.
S&F in replacement of PVC insulated and sheathed flexible cable 3 core with copper conductor of size 2.5 sqmm complete all as specified and directed by Engr in Charge.
S&F stainless steel tank of capacity 25 ltr as per sample complete all as specified and directed by Engr in Charge.
S&F stainless steel tank of capacity 15 ltr as per sample complete all as specified and directed by Engr in Charge.
Deduct Schedule of Credit of Rs (-) 92193.00 (Minus) as listed in Schedule 'A' (Contd). Contract Sum shall be arrived after deducting the credit amount. Note :- Tenderers will not quote against this item being a firm amount.
Please Enable Macros to View BoQ information
stage.html
html • 0.07 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx