Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAdmitted-Finance | ₹27.0 L | L1 | Admitted-Finance |
| 2 | L2₹28.8 LAdmitted-Finance | ₹28.8 L | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | M/S BILAL AHMAD SOFI L2 | M/S Noor Mohammad Shalla L1 |
|---|---|---|---|---|---|
| 1.00Comprehensive Maintenance of DG Sets with AMF Panel of Make: Greaves/TATA/Cummins/ Kirloskar (KOEL) including preventive maintenance checks of engine and alternator for trouble free function as per recommendation and one qualified DG mechanic for attending break down/ complaint as and when required basis to rectify breakdown immediately,monthly maintenance are regular basis complete with Preventive maintenance'B' check once a 250 hrs or 3 months inclusive replacement of required necessary spares Fuel filter, by pass filter , lube oil filter and Air filter complete sets along with rectification of minor defects and cleaning of coolant tank with blower and tuning of engine for DG set as listed below all as specified and directed by Engr-in-charge. | |||||
| 1.01 | 125 KVA DG Set -06 Nos ( Location:- ADM Block, Record office, 33/11 KV MRS, Pump house, Server Room & MT Inst) | 36 | Each Month | 700 ₹25,200 Lowest | 2,000 ₹72,000 |
| 1.02 | 100 KVA - 01 No ( Location :- OTM STP) | 6 | Each Month | 500 ₹3,000 Lowest | 1,900 ₹11,400 |
| 1.03 | 52.5 to 82.5 KVA DG Set -04 No ( Location:- Auditorium, Conference Hall, Shooting Range & M I Room ) | 24 | Each Month | 500 ₹12,000 Lowest | 1,800 ₹43,200 |
| 1.04 | 30 to 40 KVA DG SET-03 Nos ( Location:- Tathwade Gym, Edg Block, STP) | 18 | Each Month | 500 ₹9,000 Lowest | 1,700 ₹30,600 |
| 1.05NOTE FOR ITEM NOs: 1.01 to 1.04 (a) Cost of materials and labour as mentioned in Section-2 are not included with Comprehensive Maintanance, i.e. item No. 1.1 to 1.104 here-in-before. (b) Contractor has to carry out monthly maintenance with examination of suction and exhaust valves for smooth operation of DG Sets. (i) Examination of fuel injection, nozzles. (ii) Check clearnce of suction and exhaust valves and adjust if required, (iii) Checking of oil filters, fuel filters screen filters assy. (iv) Maintenance of coolant level all as directed by the Engineer-in-charge. (v) Change of Hydraulic governor oil (vi) Change of anerold oil | |||||
| 1.06Notes Contd.../ (vii) Clean alternator winding in position by forced air and internal surfaces lubricate DE & NDE bearings (viii) Tightining of all nut bolts.(ix) Greasing of all parts. (x) Test IR value of alternator winding and recording the readings (xi) Checking of any leaking in fuel & oil lines and rectification of the same. (xii) Any other check as reqd for efficient running of equipment all as specified & directed by Engr-in-Charge. (xiii) The rates quoted against the above mentioned Items is deemed to be included for cost of labour, cost of T & P required for replacement of unserviceable parts and cost of handling / transportation of defective item to & from civil workshop for repair if required. (e) The contractor shall carry out routine checking of the complete DG Sets and rectify the minor/major defects noticed immediately. If complaints were not attended within 4 hrs the following penalties will be imposed and deducted from contractors. | |||||
| 2.00 | Supply and fixing in repairs of Rubber hose set for DG set of capacity 30 to 125 KVA complete all as specified and directed by Engr-in-charge. Make: As Per OEM Recommendation all as specified and directed by Engr-in-charge. | 5 | Each set | 600 ₹3,000 Lowest | - |
| 3.00 | Dismantling/ taking out old unserviceable self starter assembly 24/12 volts from the DG set. Material and labour for rewinding with super enamelled copper wire of existing size & insulating the field coil assy, replacing bentec assy of the self starter assembly 24 Volts and refixing the same after repairs and testing complete all as specified & directed by Engr-in-Charge. | 3 | Each Job | 500 ₹1,500 Lowest | - |
| 4.00 | Supply and fixing in replacement of battery charger capacity 6 Amp, 12 Volts for DG set complete all as specified and directed by Engr-in-Charge. | 2 | Each | 3,000 ₹6,000 Lowest | - |
Tender Value
₹41.3 L
EMD Value
₹83,000
Closing Date
23 Jul 2026, 6:00 pmClosed
Lt Col Sanjay Siwach, GE
GE 970 EWS C/o 56 APO PIN-913970
REPAIR /MAINT OF DG SETS, AMF PANELS, LT SERVO STABILIZERS, AIR HEATING AND HOT WATER PLANTS AND CONNECTED WORKS AT JAK LI RC UNDER GE 970 EWS
2026_MES_773843_1
GE 970 EWS-67(T)/2026-27
Open Tender
Civil Works
Item Rate
JAK LI RC SRINAGAR
As per tender documents
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹83,000
Yes
14 Aug 2026
20 Jun 2026
25 Jul 2026
20 Jun 2026
23 Jul 2026
6 Jul 2026
20 Jun 2026 - 11 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Comprehensive Maintenance of DG Sets with AMF Panel of Make: Greaves/TATA/Cummins/ Kirloskar (KOEL) including preventive maintenance checks of engine and alternator for trouble free function as per recommendation and one qualified DG mechanic for attending break down/ complaint as and when required basis to rectify breakdown immediately,monthly maintenance are regular basis complete with Preventive maintenance'B' check once a 250 hrs or 3 months inclusive replacement of required necessary spares Fuel filter, by pass filter , lube oil filter and Air filter complete sets along with rectification of minor defects and cleaning of coolant tank with blower and tuning of engine for DG set as listed below all as specified and directed by Engr-in-charge. | |||||
| 1.01 | 125 KVA DG Set -06 Nos ( Location:- ADM Block, Record office, 33/11 KV MRS, Pump house, Server Room & MT Inst) | 36 | Each Month | - | - |
| 1.02 | 100 KVA - 01 No ( Location :- OTM STP) | 6 | Each Month | - | - |
| 1.03 | 52.5 to 82.5 KVA DG Set -04 No ( Location:- Auditorium, Conference Hall, Shooting Range & M I Room ) | 24 | Each Month | - | - |
| 1.04 | 30 to 40 KVA DG SET-03 Nos ( Location:- Tathwade Gym, Edg Block, STP) | 18 | Each Month | - | - |
| 2 | Supply and fixing in repairs of Rubber hose set for DG set of capacity 30 to 125 KVA complete all as specified and directed by Engr-in-charge. Make: As Per OEM Recommendation all as specified and directed by Engr-in-charge. | 5 | Each set | - | - |
| 3 | Dismantling/ taking out old unserviceable self starter assembly 24/12 volts from the DG set. Material and labour for rewinding with super enamelled copper wire of existing size & insulating the field coil assy, replacing bentec assy of the self starter assembly 24 Volts and refixing the same after repairs and testing complete all as specified & directed by Engr-in-Charge. | 3 | Each Job | - | - |
| 4 | Supply and fixing in replacement of battery charger capacity 6 Amp, 12 Volts for DG set complete all as specified and directed by Engr-in-Charge. | 2 | Each | - | - |
| 5 | ditto- all as per item no 4 above but capacity of 15 Amp, 24 Volts for DG set. complete all as specified and directed by Engr-in-Charge. | 2 | Each | - | - |
| 6 | Supply and fixing in replacement aganist repairs of stop solenoid/ shut off valve of capacity 30 to 125 KVA DG Sets of existing make along with screen Filter including wiring connecting to panel circuit, starting and testing on load complete all as specified and directed.Make: As Per OEM Recommendation all as specified and directed by Engr-in-charge. | 3 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
Tender67T_merged.pdf
Tender Documents • 2.32 MB
BOQ_866492.xls
BOQ • 13.19 MB
Corrigundam67T.pdf
PDF • 0.32 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].