Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹31.6 L+₹3.6 L (13.0%)Rejected-AOC 7 MULLAI NAGAR MAIN ROAD WEST TAMBARAM CHENNAI 600045 | CHENGALPATTU | TAMIL NADU | 600045 | L2 | Rejected-AOC Rejected | |
| 3 | L3₹35.0 L+₹7.0 L (25.1%)Rejected-AOC | L3 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹72,000
Closing Date
23 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (NAVY) CHENNAI
Commander Works Engineers Navy Military Engineer Services INS Adyar Old Building Fort St George Rajaji Salai Chennai 600 009
REPAIRS/ REPLACEMENT/ OVERHAULING/SERVICING OF HT 11 KV INFRASTRUCTURE, CABLES AND JOINTS IN VARIOUS LOCATIONS AT ARAKKONAM
2021_MES_477468_1
CWE/NAVY/ARK/87654 OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
365 days
ARAKKONAM
As Per Tender Documents
9 documents required · 9 mandatory
₹500
GE MAINT NAS ARAKKONAM
₹72,000
Yes
23 Dec 2021
24 Sept 2021
25 Oct 2021
24 Sept 2021
23 Oct 2021
9 Oct 2021
25 Sept 2021 - 6 Oct 2021
60 days
Amount
Material and labour for collecting the transformer oil from the site locations under GE (Maint) NAS Arakkonam, sending the same for testing to approved lab for testing of BDV and ACIDITY, submission of certificates/reports to Deptt complete all as specified and as directed.
Material and labour for de-hydration and filtration of transformer oil through on load mobile stream liner transformer oil filtration plant at various site and various capacity installed at pole, floor, plinth mounted with all accessories connected to transformer to carrying out filtration of oil for desired dielectric strength all as per IS-335 i.e not less than 60 KVA at 25mm gap including testing after filtration and recording before and after testing results, complete all as specified and directed.
Note : a) Oil only to be filtered after getting recommendation alongwith BDV as per IS. 335. b) After filtration of oil the following points have to be ensured:- i) Oil level at the conservator tank should be in maximum limit. ii) After filtration process, samples of oil to be collected from all pertaining transformers/HT switch gear and the following parameters to be got checked from lab:- (aa) Moisture content (ab) Tan Delta (ac) Specific Resistivity (ad) Interfacial Tension (ae) Sludge/Sediment (af) Flash point in Celsius iii) Test result for IR value for primary and secondary windings and die electric strength of transformer oil to be submitted for record.
Material and labour for servicing, overhauling HT RMU 11 KV (two incoming and one outgoing) of various make/type including servicing to Manual operated Load Break Switch-02nos & VCB-01 no, including checking door lock system, mechanical and electrical interlocking system, complete wiring checking and tightening all the mechanical and electrical joints and replacement of unserviceable spare parts complete and writing with paint the Feeder name and checking the functionality in position after servicing complete all as specified and as directed
Material and labour for servicing, overhauling HT VCB panel complete 11 KV 400-800 Amps, upto 500 MVA of various make/type and checking door lock system, checking for phase sequence, mechanical and electrical interlocking system, complete wiring checking of relays, trip coil, spring charge motor, closing coil etc, tightening all the mechanical and electrical joints complete and writing with paint the Feeder name and checking the functionality in position after servicing complete all as specified and as directed. Including recording the results. Note: (i) Quoted rate includes Supply and Fix all minor spares and wires required during servicing. (ii) Replacement of unserviceable major spare parts shall be measured and paid separately as supply only under relevant items here-in-after however fixing charges/labour cost for the spares to be included in the quoted rate.
Supply only the following spare parts for HT VCB panel complete 11 KV 400-800 Amps, upto 500 MVA of various make/type all as specified and as directed. NOTE : (i) Labour cost for taking down old u/s item and fixing of following new items deemed to be included in rate quoted for Item No.4 above.
Vacuum interrupter (bottle type)
Emergency push button
8 window alarm enunciator with RS 485 PORT
spring charging motor any type
Anti-condensation space heater
Thermostat
Hooter
Digital Multifunction meter Class 1.0. with RS-485 port
Battery for Power pack, 12 V,7AH
Material and labour for calibration of HT VCB panel complete 11 KV 400-800 Amps, upto 500 MVA of various make/type including relay, tripping mechanism etc as per standard/ specified/directed by OEM certified agency and submitting report all as specified and as directed.
Dismantling and taking down unserviceable mild steel cross arms, bracings, supports, channels, angles, clamps etc complete all as specified and as directed.
Supply and fix cross arms, bracings, supports clamps and back plates fabricated from structural steel sections incl. nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of two coat of aluminium paint over a coat of red oxide primer including preparing the surface all as specified and as directed.
Supply and fix danger notice plate of 1.6mm thick size HT 25 x 20 cm of mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved of size including taking down rusted danger plates complete all as specified and as directed
Supply and fix replacement cable jointing kit for 11 KV grade (Earthed) cable for indoor type end termination through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq. mm including taking up old unserviceable cable, cutting/taking out joint etc complete all as specified and as directed
Supply and fix replacement cable jointing kit for 11 KV grade (Earthed) cable for outdoor type end termination through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sq mm including taking up old unserviceable cable, cutting/taking out joint etc complete all as specified and as directed
Surface dressing upto 15cm deep in and around transformer yard , four pole, two pole, three pole structure vicinity and clearing of vegetation/soil to a distance not exceeding 50m complete all as specified and as directed
Material and labour for loose filling and spreading with aggregates/broken stone or boulders 40mm gauge complete all as specified and as directed
Supply and fixing switch air break, gang operated, triple pole, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, having current rating upto 400 Amps for working pressure 11000 Volts suitable for horizontal mounting fixed type complete with 9 insulators including taking down old existing, complete all as specified and as directed
Supply and fixing air break (switch) insulator for 11000 volts single pole outdoor type suitable for horizontal/vertical switch air break, gang operated, having current rating upto 400 Amps including necessary bolts, nuts and taking down old unserviceable one complete all as specified and as directed.
Material and labour for Precast concrete (PCC) cable route indicator of size 350mm x 200mm x 200mm with slanting top duly embossed' HT CABLE' or 'HT LOOP' including and planted on PCC foundation 1:3:6 type C2(40mm aggregate) 450x450x100mm complete including taking out old damaged indicators and demolition of PCC near old indicators, necessary earth work, site clearance, painting and preparation of surface complete all as directed.
Supply and fix replacement cable jointing kit for 11 KV grade (Earthed) cable for indoor type end termination through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq. mm including taking up old unserviceable cable, cutting/taking out joint etc complete all as specified and as directed
Supply and fix in replacement cable jointing kit for 11 KV grade (Earthed) cable for outdoor type end termination through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 sq mm including taking up cable, cutting/taking out old unserviceable joint etc complete all as specified and as directed
Material and labour to carryout test and identify exact location and nature of defect in 11 KV HT UG cable any size/type using cable fault locator/equipment including finding of cable route as per site requirement including transportation, testing after rectification and restoring of the supply in all respects and commissioning etc complete all as specified and as directed. Note: Earth work, cable joints as per site requirement shall be measured and paid separately under relevant item of the schedule.
Taking up old /existing unserviceable defective HT 11000V UG Cable of size 185 sqmm 3 core from the existing trenches/ near panels and keep a side carefully and segregating serviceable portion of cable for reuse incorporating in the site complete all as specified and as directed Note: Earth work shall be measured and paid separately.
All as per item no 20 here-in-before but for 95 sqmm 3 core
Supply, laying, testing for replacement against unserviceable part of item No 21 here-in-before XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sqmm 3 core complete all as specified and directed
Supply, laying, testing for replacement against unserviceable part of item No 22 here-in-before XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 95 sqmm 3 core complete all as specified and directed
Relaying of serviceable portion XLPE insulated 11000V HT heavy duty aluminium conductor, 11000 volts grade cable 185 sqmm 3 core size taken up from item 22 here-in-before all as per site requirement complete all as specified and directed
Relaying of serviceable portion XLPE insulated 11000V HT heavy duty aluminium conductor, 11000 volts grade cable 95 sqmm 3 core size taken up from item 23 here-in-before all as per site requirement complete all as specified and directed
Cutting the existing road for 0.30M width , 0.60M depth for laying cable incl excavation in any type of soil, returning filling , removal and including Material and labour PCC 1:4:8 type D2 (40mm graded aggregate) of 15 cm thick for making good the disturbed road portion all as directed and specified. (Note: Gl pipe with all fittings shall be measured and paid under the respective item)
Supply and fix for replacement cable jointing kit for 11KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm including taking up old unserviceable cable, cutting / taking out joint etc complete all as specified and as directed Note:- Earth work shall be measured and paid separately.
Supply and fix replacement cable jointing kit for 11KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 Sqmm including taking up old unserviceable cable, cutting/taking out joint etc complete all as specified and as directed Note - Earth work shall be measured and paid separately
Material and labour for PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) in floors for ducts/floors/ road etc all as per site requirement complete all as specified and directed
Material and labour for disconnecting the HT & LT supply from transformer, removing of top cover along with vent pipe joints, clean/flushing the core assembly by applying new oil through filtration plant and checking for loose connections, tap changer point HT/LT, connecting terminals and oil leakage at all joints, replacing of gaskets, oil seal, HT & LT insulator bushings, HT terminal studs and acrylic sheet indicator alongwith rubber gasket after checking the insulation resistance value by 1000 mV megger and recording the IR value of HT to earth and LT to earth, reconnecting HT & LT supply line, commissioning in all respects complete all as specified and directed for the following transformers :- Note : Spares such as HT/LT insulator, bush, HT/LT terminal, brass studs, gasket, transformer oil for cleaning the core and shell shall be measured and paid separately under relevant items of the schedule
Pole mounted (Sub station E & F) 63 KVA Transformer
Floor mounted ( Sub station 1) 100 KVA Transformer & Localizer.
Floor/Pole mounted ( Sub station at TS, Thirumalpur pump house, Poigaipakkam Defence qtrs and IOC) 160 KVA Transformer.
200 KVA to 250 KVA Transformer at Sub station at Magazine and ATH Storage Accommodation.
315 KVA to 400 KVA Transformer at Sub station at D & Maint Hangar.
500 KVA Transformer at Sub station at A, C, G, H & 4 Hangar, Sub stn J & Sub stn N
630 KVA Transformer (1+2) Floor mounted at Sub station at E & F.
800 KVA transformer at Sub station N
Supply and filling for toping up of transformer oil for transformer of various capacity (floor/plinth mounted etc), BDV should as per IS 335 of complete all as specified and as directed
Supply and replacement of silica gel of superior quality of 5 to 10 mm grade complete all as specified and directed.
Dismantling insulators of any type / lightning arrestors of any type of any size each complete all as specified and directed
Material and labour for replacement disc type insulator, porcelain, vitreous 145 mm high and 255 mm dia, ball and socket type, white, brown or green single disc assembly of 11000 volts complete all as specified and as directed
Material and labour for replacement pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade complete all as specified and as directed
Servicing the 11 KV GOD by cleaning the contacts, disc / pin insulator with CTC and applying the petroleum jelly at the contact point / down rod links for smooth operation including replacing the rusted / corroded bolts & nuts and defective insulator of GOD as required at site. Note:- (i) Insulator, male & female contacts ,copper strip shall be measured and paid separately as supply only. (ii) labour cost for taking down old u/s component and fixing of following new items deemed to be included in the quoted rate
Supply only Male / Moving contacts ( set of 3 Nos )
Supply only Female / Fixed contacts ( set of 3 Nos )
Supply only Copper tinned strip / Belt (set of 3 Nos )
Material and labour for replacement of GI tube light grade 100 mm with all fittings complete for cable protection near poles, installations, trenches and road crossing complete including taking up old GI Pipe complete all as specified and as directed
Material and labour for galvanized iron tubing 50 mm bore light grade with all fitting laid in wall / floor / under road/culvert/on pole for protection of earth strip including providing fixing clamps, bolts and nuts of suitable size as required complete all as specified and as directed.
Supply and fix on pole/ buried in ground Earth continuity conductor GI strip 32mm x 6mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles. complete all as specified and as directed
Supply and replacement of old and unserviceable phase indication lamps with LED 110 Volts suitable for HT VCBs as per site requirement complete all as specified and directed
Material and labour for painting of HT two pole structure of 11.0 meter length after preparing / scraping the metal surface with emery sheet in all respect for making smooth surface and painted with two coats of aluminium paint including cross arms / MS channels etc complete all as specified and directed
Material and labour for painting of HT four pole structure of 11.0 meter length after preparing / scraping the metal surface with emery sheet in all respect for making smooth surface and painted with two coats of aluminium paint including cross arms / MS channels etc complete all as specified and directed. Note for SI No 44 & 45 :- The poles shall be painted with yellow and black colour anti corrosive enamel paint alternatively at the interval of 50 cm, upto 1.5 mtr above the ground level and writing the pole No & Feeder No complete all as specified and directed
Material and labour for spray painting the following transformer complete by removing existing oil traces, paint by scraping and applying two coats of approved colour synthetic enamel paint and writing lettering SM / MES No and date of oil tested etc complete all as specified and directed
Transformer of capacity upto 160 KVA
Transformer of capacity upto 400 KVA
Transformer of capacity 500 KVA to 630 KVA
Transformer of capacity 800 KVA
Material and labour for Set of 3 HV rods along with oil gasket & oil seal and set of 4 LT terminal rod along with gasket and oil seal, transformer of capacity upto 160 KVA complete all as specified and as directed
Material and labour for Set of 3 HV rods along with oil gasket & oil seal and set of 4 LT terminal rod along with gasket and oil seal, transformer of capacity upto 400 KVA all as specified and directed.
Material and labour for Set of 3 HV rods along with oil gasket & oil seal and set of 4 LT terminal rod along with gasket and oil seal, transformer of capacity 500 KVA to 630 KVA all as specified and directed
Material and labour for replacement of breather assembly transparent PVC body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia as per site requirement/capacity of transformer upto 160 KVA complete all as specified and directed
Material and labour for replacement of breather assembly transparent MS body with top and bottom portion pressed with metallic cover, filled with silica gel blue in colour and suitable for fixing on existing pipe of size 15/20/25 mm dia as per site requirement /capacity of transformer upto 1000 KVA complete all as specified and directed.
Supply and fix gun metal glob or gate valve iron wheel head, GM ISI marked suitable for 25 mm dia bore of pipe screwed both ends for iron pipe or for socket or union of various capacity transformer drain valve complete all as specified and directed.
Material and labour for replacement the explosion vent diaphragm suitable size as per sample complete all as specified and approved
Material and labour for disconnecting the LT / HT connection from transformer and dismantling from pole / foundation and removing separate and opening of transformer for rewinding with super enamelled copper conductor of existing gauge including varnishing drying by electric furnace method refixing the same commissioning and testing the same in existing load and shifting of transformer one place to another capacity of transformer upto 600 KVA complete all as specified and directed
Taking out burnt primary winding rewinding the same with super enamelled copper wire with existing gauge of capacity of transformer 63 KVA to 160 KVA including new insulation complete all as specified and directed
Taking out burnt primary winding rewinding the same with super enamelled copper wire with existing gauge of capacity of transformer 200 KVA to 315 KVA including new insulation complete all as specified and as directed
Taking out burnt primary winding rewinding the same with super enamelled copper wire with existing gauge of capacity of transformer 400 KVA to 500 KVA including new insulation complete all as specified and directed
Taking out burnt secondary winding rewinding the same with super enamelled copper wire with existing gauge of capacity of transformer 63 KVA to 160 KVA including new insulation complete all as specified and directed
Taking out burnt secondary winding rewinding the same with super enamelled copper wire with existing gauge of capacity of transformer 200 KVA to 315 KVA including new insulation complete all as specified and directed
Taking out burnt-secondary winding rewinding the same with super-enamelled copper wire with existing gauge of capacity of transformer 400 KVA to 500 KVA including new insulation complete all as specified and directed by Engr-in-Charge
Material and labour for Earthing complete with GI earth plate electrode of size 600mm x 600mm x 6 mm thick buried directly in ground vertically to a depth of not less than 2.25 m deep below normal ground level, with top edge of the earth plate at a depth of not less than 1.5 mtr below ground connected to Gl earth strip 32 x 6mm by means of GI bolts and nuts, washers and Gl earth strip protected by Gl pipe light grade 50mm bore upto 7.5 mtr and connecting to HT/ LT switch gear etc as per site requirement including necessary excavation, earth work in any type of soil, PCC 1:3:6 type C-1 earth chamber, 40mm thick RCC cover with 6mm dia MS bars 10cm C/C on both ways as reinforcement complete all as shown in electrical plate No 3 of MES Schedule Part 1 (2009) connected to earthing test points complete all as specified and as directed by Engineer-in-Charge. Note:- (i) Quoted rate deemed to include necessary earth work, PCC chamber, RCC cover, reinforcement, removal of surplus soil, site clearance etc. (ii) GI earth strip 32 x 6mm, GI tubing light grade 50mm dia upto 7.5 mtr deemed to be included the rate quoted by the contractor. (iii) Beyond 7.5 mtr the Gl earth strip 32 x 6mm & Gl pipe light grade 50mm dia shall be measured under relevant item of the schedule.
Supply and Fix Danger notice plate of 1.6mm thick size LT 25 x 20 cm of mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved of size including taking down rusted danger plates complete all as specified and as directed
Material and labour for synthetic insulating mat of size 2m x 1m x 25 mm including taking unserviceable mats complete all as specified and directed
Material and labour for MS Chequered plate of thickness not less than 4 mm and size/area as per site requirement to cover cable duct openings including repairing works to edges of Duct with appropriate PCC to place MS Chequered plate equally on the duct in the installations complete including painting with two coat of synthetic enamel paint of approved tint over a coat of red oxide primer and taking out the broken PCC duct covers all ac certified and directed
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 m in depth for taking out /for laying under ground cables/pipes etc and getting out in soft/loose soil complete all as specified and directed
Supply and laying unreinforced pre cast concrete cable cover class HV type 1 flat size 300 x 180 x 40 mm for cable protection complete all as specified and as directed
Supply and spreading riddled earth in trenches, including levelling, punning for cushioning of cables all as specified. NOTE: Punned thickness of sand cushioning shall be measured.
Returning filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and directed
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed
Relaying in trenches serviceable un-reinforced precast concrete cable cover, retrieved from item no 66 complete all as specified and as directed
Raju Builders
HASINI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .