| 1 | L1₹7.6 LAccepted-Finance 38A PHASE II RAVINDRA ENCLAVE BALTANA PB | ₹7.6 L | L1 | Accepted-Finance L1 |
| 2 | L2₹7.8 LRejected-Finance 6 GURU GOBIND SINGH NAGAR DHAKOLI ZIRAKPUR | S A S NAGAR | PUNJAB | 140103 | ₹7.8 L | L2 | Rejected-Finance not L1 |
Tender Value
₹7.8 L
EMD Value
₹15,513
Closing Date
3 Jun 2026, 11:00 amClosed
Executive Engineer, Electrical Division, M.C., Chd
Executive Engineer, Electrical Division, M.C., Chd
Special Repair Renovation of Fish Market, Sector 41, Chandigarh
2026_MCC_91918_3
56/E/MCC/2026
Open Tender
Electrical Works
30 days
Special Repair Renovation of Fish Market, Sector 4
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹15,513
12 Jun 2026
26 May 2026
3 Jun 2026
26 May 2026
3 Jun 2026
26 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount | Item Code |
|---|---|---|---|---|---|---|
| 1 | Providing and fixing of front doors in place of missing or broken door of existing pedestal of size 1200x900x350 mm. The door is to be fixed by welding hinges at site with the help of welding set. The job also includes the cost of painting of the complete pedestal to the entire satisfaction of Engineer in charge. | - | Mtrs. | 2,470 | - | BI01010001010000000000000515BI0100001113 |
| 2 | S/F DP MCB isolator: Supplying & fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make of Anchor, Havells, Legrand, ABB, L&T, Siemens. The work shall be executed to the entire satisfaction of Engineer in charge. 63 amps | - | Mtr | 512 | - | BI01010001010000000000000515BI0100001114 |
| 3 | Supply & Erection of PVC Insulated sheathed) Copper Conductor Cable ISI marked size 2 core 6 mm2.
Supply & Erection of ISI Marked PVC insulated 2 core 6 mm2 cable of Copper Conductor (Sheathed) make Finolex/ Lapp/ Polycab/ Havell's/ left bare in pipe of suitable size excluding cost and erection of pipe/pole etc. (i) Cable size 2 core 6 mm2 Copper Conductor 1100 Volts Grade. The work shall be executed to the entire satisfaction of Engineer-in-charge. | - | Mtr | 233 | - | BI01010001010000000000000515BI0100001115 |
| 4 | S/F’C series, SP MCB
Supply and fixing 6 amps to 32 amps rating, 240 volts ‘C’ series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB Complete with connections testing and commissioning etc as required. Single pole 16 Amps “C” series Make of Anchor, Havells, Legrand, ABB, Siemens, L&T. The work shall be executed to the entire satisfaction of Engineer in charge. | - | Sets | 235 | - | BI01010001010000000000000515BI0100001116 |
| 5 | Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminium armoured cable loose in trench/pipe:-
Supply & laying of ISI marked 4 core 16 mm sq PVC Insulated Aluminum conductor armoured cable of make Havells/ Finolex/ Ecko/ Lapp/ Cirtina/ Sunhome/ Polycab/ KEI/ conforming IS:1554 (Pt.1) amended. The cable to be laid in trench/ pipe as per DSR Code 7.5.1/2018 MV CB PIP-25 Part-II (External). Material Testing report to be submitted and material to be supplied at site after confirmation from Engineer-in-charge. The specification of the cable as below:-
i) Conductor – Aluminum
ii) Core – 4
iii) Working Voltage – 1100 V
iv) Nominal Cross Section – 16mm2 v) Minimum No. of Wire – 7/6
vi) Insulation Thickness – 1.0mm (Nominal)
vii) Inner Sheath Minimum Thickness – 0.3mm
viii) Outer Sheath Minimum Thickness – 1.40mm
ix) Nominal size of Armoured Wire/Strip – 4x0.8mm
x) Approximate O.D. – 22mm
Maximum d.c. Resistance at 20 Deg. C – 1.91 ohm/km
The work shall be executed to the entire satisfaction of Engineer-in-Charge. | - | Nos | 248 | - | BI01010001010000000000000515BI0100001117 |
| 6 | S&E of Mouled Case Circuit Breakers (MCCB) of rating 63 Amp with Breaking Cap 26 kA, 415 Volts.
Supply & Erection of 3 pole, 26 kA, 63 Amp MCCB with adjustable thermal and magnetic setting having Ics 75% of Icu. The MCCB is to be fixed in the feeder pillar complete in all respects. The MCCB should be make Havells/ ABB/ L&T/ Legrand/ Schneider. The work shall be executed to the entire satisfaction of Engineer-in-Charge. | - | Nos | 6,297 | - | BI01010001010000000000000515BI0100001118 |
| 7 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle
panel, making connections, etc. as required The TP&N should be make Havells/ ABB/ L&T/ Legrand/ Schneider. 200 A TP&N DSR 2.1.6 | - | Nos | 9,754 | - | BI01010001010000000000000515BI0100001119 |
| 8 | Supply & Laying of DWC pipe 51/63mm without hand bockey:- DSR 14.16.1
Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) Without Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930, complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling of digging including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. | - | Sets | 210 | - | BI01010001010000000000000515BI0100001120 |
| 9 | Supply & Laying of DWC pipe 51/63mm with hand bockey:- DSR 14.15.1 Supply and Laying of pipe (OD-63 mm & ID-51 mm nominal) Double Wall Corrugated (DWC) With Hand Bockey High Density Polyethylene pipe ISI marked (HDPE Density 240 to 958 KG/Cm3) having corrugation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1+0.1mm and for inside layer 1.2+0.1mm maintenance free, ‘C’ value over 150 with lowest frictional losses, good weathering resistance, with all accessories like socket, bend, couplers etc. conforming to IS 14930,/ IS-16205 part ii complete with fitting and cutting, jointing etc.direct in ground (depth as per the directions of Engineer in charge or upto 75cm below ground level) including excavation and refilling the trench but including sand cushioning and protective covering etc., complete as required and PSEN-50086 (P-I & II) of Make Gemini, Rex, Duraline. The entire satisfaction of Engineer-in-Charge of work. | - | Sets | 228 | - | BI01010001010000000000000515BI0100001121 |
| 10 | Supply & Erection of Exhaust Fan (14” sweep (300mm) 900 RPM of Panasonic (Anmol 13160) Havell’s/ Bajaj/ Crompton make complete with motor blades along with louver to be installed on existing hole in wall/ glazing with suitable arrangement. The rate includes cost of all labour, carriage to site, testing, commissioning of Exhaust fan & connection to existing light panel. The job shall be executed to the entire satisfaction of Engineer-in-charge. | - | Sets | 4,178 | - | BI01010001010000000000000515BI0100001122 |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.76 MB
BOQ_113473.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid