Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.0 LAccepted-AOC ADAM KANAN JHARGRAM 721507 | JHARGRAM | WEST BENGAL | 721507 | L1 | Accepted-AOC L1 | |
| 2 | L2₹45.1 L+₹6,834.62 (0.15%)Rejected-Finance 00 DEY ENTERPRISE SODEPUR 9 10 PITS COLLIERY ASANSOL BARDHAMAN WEST BENGAL 713372 | PASCHIM BARDHAMAN | WEST BENGAL | 713372 | L2 | Rejected-Finance L2 | |
| 3 | L3₹45.1 L+₹11,620.18 (0.26%)Rejected-Finance 1 6 FAKIR CHAKRABORTY LANE | L3 | Rejected-Finance L3 | |
| 4 | L4₹45.2 L+₹17,579.18 (0.39%)Rejected-Finance 18 DHRUBESH CHATTERJEE LANE UTTARPARA HOOGHLY 712258 | UTTARPARA | HOOGHLY | WEST BENGAL | 712258 | L4 | Rejected-Finance L4 |
Tender Value
Refer Docs
EMD Value
₹94,000
Closing Date
22 Oct 2019, 5:00 pmClosed
Executive Engineer,MMD.PHE DTE
Office of the Executive Engineer, Midnapore Mechanical Division P.H. Engineering Directorate Inda P.H.E. Complex, Kharagpur
Improvements of Substation Equipments and other Electrical accessories at Head Works Site under Dherua Piped Water Supply Scheme, Block Medinipore sadar, Dist Paschim Medinipore. under Midnapore Mechanical Division P.H.E Dte
2019_PHED_246952_2
WBPHED/EE/MMD/NIeT_10OF2019_20
Open Tender
Electrical Work/ Equipment
Item Wise
60 days
Kharagpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹94,000
Yes
27 Jan 2020
1 Oct 2019
25 Oct 2019
2 Oct 2019
22 Oct 2019
2 Oct 2019
PART-A Supply , delivery & Storage at site of floor mountain, steel sheet enclosed 12kV, 25KA, 3 ph, 50 Hz, 630 Amp. drawout type 3 panel Indoor VCB complete with DC power pack arrangement and all acessories as per technical specification given in NIT. (Siemence/ABB/Pascal/Audrue Yuls)
Supply, Delivery and storage at site 11 / 0.433 KV, 3 Ph, 250 KVA, 50 Hz, Dyn - 11, ANON Coolong type, outdoor floor mounted Copper wound Transformer manufactured as per IS: 2026 with Offload tap changer having + 5 % to -15 % in steps of 2.5% and as per technical specification given in NIT. (Siemens/ABB/AEG/KEL)
Supply, Delivery and Storage at Site 2 mm. thick CRCA Sheet Steel Enclosed Cubical type Indoor Floor Mounted 415 Volt PDB Panel having required Feeders as per specification given in NIT. (Make-ECS/RNR/PCE Progect/Jolly Enginnering)
Supply, delivery and storage at site of the following cables- i) 185 sq mm , 3 core , 11 KV (E) Grade XLPE insulated HT Al Armoured cable as per IS 7098 / (PART-II) 1985 with latest amendments. .(From VCB to HT AVR toTRANSFORMERs)
ii) 300 sq mm , 31/2 core , 1.1 KV Grade XLPE insulated Al Armoured cable as per IS 7098 (Part - I) 1988 ( from Transformer secondary to incomer of PDB Cum MCC panel at P/H )
iii) 95 sq mm , 3 core , 1.1 KV Grade XLPE insulated Al Armoured cable as per IS 7098 (Part - I) 1988
iv) 35 sq mm , 1 core , 1.1 KV Grade XLPE insulated Al Armoured cable as per IS 7098 (Part - I) 1988
v) 2.5 sq mm , 10 core , 1.1 KV Grade PVC insulated Copper Armoured control cable as per relevent IS.
vi) 2.5 sq mm , 3 core , 1.1 KV Grade PVC insulated Copper Armoured cable as per relevent IS.
Supply, delivery and storage at site of following cable termination kits for Sub-Station. A) Indoor type heat shrinkable termination kit for 3 Core, 185 sq mm 11 KV (E) XLPEA cable.
Supply, delivery at site and storeage of ladder type cable tray for laying of power cable and G.I Perforated cable tray for laying of control cable at Sub-Station having proper M.S. structural support.
Earthing protection for substation installation as per ISS and IE rules and as per technical specification of NIT.
Providing M.S. angle & removable 8mm thick chequered plate over the open portion of the cable trench in the substation/electrical room after installation of the equipment as per diection of EIC & with a provision of lifting lug over the MS chequered plate at the head works.
PART_B Installation of all items mentioned as in PART A ( except Sl no8) including supply of all erection items, as required for installation of Transformer, PDB Panel including necessary, painting, jointing of cables, termination by suitable rated sockets, by engaging skilled technician all complete as per relevent IE Rules with the entire satisfaction of EIC and as per detail technical specification given in NIT.
High pressure testing of the Sub-Station including relevant testing of 11 KV cable, earthing etc. by approved agency of Directorate of Electricity, Govt. of West Bengal and obtaining approval certificate of sub-station from Director of Electricity as per direction and to the entire satisfaction of EIC.
Commissioning of the entire installation i.e. Indoor type sub-station ( 1 X 11 / 0.433 KV, 250 KVA) , PDB Panel, etc. as per direction and to the entire satisfaction of E.I.C.
DEY ENTERPRISE
H.K.DAS AND CO.
R.N.S.TRADING
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .