Construction of Community Hall at Lal Mitti Junction Nabagram Panchayat, Ward No.2, Diglipur Tehsil under MPLADS, CD, APWD, Diglipur. Sw- Providing IEI
2024_APWD_13364_1
NIT No. 116/EE/CD/APWD/DP/2023-24
Open Tender
Electrical Works
Works
30 days
Community Hall Nabagram, Diglipur
Please refer Tender documents.
6 documents required · 6 mandatory
₹0
₹4,683
21 Feb 2024
8 Feb 2024
21 Feb 2024
8 Feb 2024
21 Feb 2024
9 Feb 2024
8 Feb 2024 - 9 Feb 2024
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 A switch
3 pin 5/6 A socket outlet
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.
6 Module (200mmX75mm)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required.
Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
Supplying of 12W LED, 6000K LED Bulk head fittings similar to Luker, cat no. LBKOVSL 12 its equivalent.
Supply of 20W LED Retrofit Tube light Batten suitable for 230 Volts,50 Hz AC supply ,Make: Crompton, Model: DIJB12LT8-20 or its equivalent to IS specification.
Supply of 20W LED,6500K, 4 Feet, Retrofit Tube light suitable for 230 Volts,50 Hz AC supply similar to Philips, Model no. 20W865 T8 IND I 2100lm or its equivalent to IS specification.
Supplying of 5 star Energy saving ceiling fans BLDC (26W to 32W), 1200mm sweep (White), Make: USHA Model: Techno Air (Without remote) or equivalent.
Providing Earthing with safe earthing electrode of galvanization 80 to 100 microns length 2000 mm, 48mm dia and inner space to be filled with crystaline conuctive mixture including filling - up with electrodite (Back fill Compound) as required for safe earth electrode and provoding masonary enclosure with cover plate haveing locking attagement etc. as required. (Similar to ASHLOK make SEE brand safe earthing or equivalent)
PALASH KANTI ROY
Biswajit Sarkar
M/s G K Construction
DILIP RAJ
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .