Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.8 CrAccepted-AOC DURGA APT INDRA NAGAR NASHIK 422009 | NASHIK | NASHIK | MAHARASHTRA | 422009 | ₹25.8 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹26.4 CrRejected-AOC | ₹26.4 Cr | L2 | Rejected-AOC L2 |
| 3 | L3₹26.9 CrRejected-AOC D 2 3 RAJAT APARTMENT SENAPATI BAPAT ROAD SHIVAJI NAGAR PUNE 411016 | PUNE | MAHARASHTRA | 411016 | ₹26.9 Cr | L3 | Rejected-AOC L3 |
Tender Value
₹23.4 Cr
EMD Value
₹11.7 L
Closing Date
30 Sept 2022, 6:00 pmClosed
Executive Engineer Public Work(East)Division Pune
Executive Engineer Public Work(East)Division Pune
Construction Of 100 Bedded Sub District Hospital At Post Supa Tal Baramati Dist Pune (INCLUDING ELECTRICAL WORK)
2022_PWDRP_832821_1
E Tender Notice No.19 for 2022-2023 WORK NO.01
Open Tender
Civil Works - Buildings
730 days
Baramati
Please refer Tender documents.
5 documents required · 5 mandatory
₹3,360
₹11.7 L
Chief Engineer, P. W. Region Office, Pune
8 Feb 2023
6 Sept 2022
3 Oct 2022
6 Sept 2022
30 Sept 2022
6 Sept 2022
6 Sept 2022 - 13 Sept 2022
13 Sept 2022
Amount
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Spec.No. : Means Bd.A.1 Page No.259
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Manual Means Spec.No. : Means Bd.A.1 Page No.259
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 m) By Mechanical Means Spec.No. : Means Bd.A.2 Page No.259
Excavation for foundation in hard murum and boulders including removing the excavated material up to a distance 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5m.) By Mechanical Means Spec.No. : Bd.A.3, Page No. 259.
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth /murum, ramming, watering including shoring and strutting etc. complete (lift upto 1.5m) By Mechanical Means Spec.No. : Bd.A.4, Page No. 259.
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material up to a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth / murum watering, ramming etc. complete. (Liftupto1.5m).ByMechanical Means Spec.No. : Bd.A.6 Page No. 260
Providing preconstructional antitermite treatment as per I.S. 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 1.0 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper.. Spec. No As director by engineer incharge.
Providing soling using 80 mm size trap metal in 15 cm. layer including filling voids with Crushed sand/grit, ramming, watering etc. complete. Spec. No As director by engineer incharge.
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer incharge in layers of 15 cm to 20 cm including watering and compaction etc. complete. Spec. No. Bd.A 11, Page No. 263
Providing and aying Cast in situ/ Ready Mix cement concrete in M-10 of trap/granite/quartzite/gneiss metal for foundation and bedding including bailing out water,Steel centering, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic microprocessor based PLC with SCADA enabled concrete Batchmixplant (Panmixer)etc.complete.With fine aggregate(Crushed sand VSI Grade)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, Steel centering, formwork ,cover blocks, laying/pumping, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd. F.3 Page No. 298 and B.7, Page No. 38
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (GROUND FLOOR )
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (FIRST FLOOR)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks compacting and roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc)Spec. No. Bd.F.5 Page No. 300 And B7, Page No 38. (SECOND FLOOR)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (GROUND FLOOR )
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (FIRST FLOOR)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. beams and lintels as per detailed designs and drawings or as directed including steel centering, formwork, cover blocks, laying/pumping, compactionand roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.6 Page No. 300 and B.7, Page No.38 (SECOND FLOOR)
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (GROUND FLOOR )
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 ( FIRST FLOOR )
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for R.C.C. slabs and landings as per detailed designs and drawings including steel centering, formwork, cover blocks, compaction, finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.8 Page No. 302 and B.7, Page No.38 (SECOND FLOOR)
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.9, Page No.38 (GROUND FLOOR )
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.9, Page No.38 ( FIRST FLOOR )
Providing and laying Cast in situ/Ready Mixcement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. chajja as per detailed design and drawings including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.F.9 Page No. 303 and B.9, Page No.38 ( SECOND FLOOR )
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (GROUND FLOOR )
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (FIRST FLOOR)
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for R.C.C. pardi of required thickness including steel centering, formwork, cover blocks, laying/pumping, compacting and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc). Spec. No. Bd.F.11 Page No. 304 and B.7, Page No. 38 (SECOND FLOOR)
Providing and laying cast in situ / Ready mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With Natural Sand / V.S.I. Quality Artificial Sand. Spec. No. : Bd.F. 13 Page No. 305. /I.S. 456 (2000) (GROUND FLOOR )
Providing and laying cast in situ / Ready mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With Natural Sand / V.S.I. Quality Artificial Sand. Spec. No. : Bd.F. 13 Page No. 305. /I.S. 456 (2000) (FIRST FLOOR)
Providing and laying cast in situ / Ready mix cement concrete M-25 of trap / granite / quartzite / gneiss metal for R.C.C. waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood / steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block). (Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer / concrete Batch mix plant (Pan mixer) etc. complete. With Natural Sand / V.S.I. Quality Artificial Sand. Spec. No. : Bd.F. 13 Page No. 305. /I.S. 456 (2000) (SECOND FLOOR)
Providing and laying Cast in situ/Ready Mix cement concrete M-15 of trap/ granite/quartzite/gneiss metal for coping to plinth or parapet, moulded or chamfered as per drawing or as directed including steel centering, plywood/ steel formwork compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.) With fine aggregate (Natural Sand / Crushed sand VSI Grade finely washed etc) Spec. No. Bd.E. 3/Page No. 288/I.S. 456 (2000 SECOND FLOOR
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No. Bd.F.17 Page No. 306. (GROUND FLOOR )
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No. Bd.F.17 Page No. 306. (FIRST FLOOR)
Providing and fixing in position TMT - FE - 500 bar reinforcement of various diameters for R.C.C. pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. Spec. No. Bd.F.17 Page No. 306. (SECOND FLOOR)
Providing fly ash brick masonry with conventional / I.S. type fly ash bricks in C.M. 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete. Spec. No. As director by engineer in charge and BDG- 2 and 5
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625 x 240 x 225)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No As director by engineer incharge (GROUND FLOOR )
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625 x 240 x 225)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No As director by engineer incharge ( FIRST FLOOR)
Providing and constructing masonry in Autoclaved Areaclaved ( Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size ( 625 x 240 x 225)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in superstucture including,striking joints,racking out joints watering and scaffolding etc.complete. Spec. No As director by engineer incharge (SECOND FLOOR)
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 x 240 x 100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out\ joints and watering compete. Spec. No As director by engineer incharge (GROUND FLOOR )
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 x 240 x 100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out\ joints and watering compete. Spec. No As director by engineer incharge ( FIRST FLOOR)
Providing and constructing masonry in Autoclaved Areaclaved (Celluar) Concrete Block of aproved manufacturer confirming to IS 2185 Part III 1984 of size (625 x 240 x 100)mm in extra fine jointing mortar of fixoblock of Ultra Tech or equivalent in half brick thick wall including 2 hoop iron strips 25mm x 1.6mm at every third course,properly bend and bonded at ends scaffolding racking out\ joints and watering compete. Spec. No As director by engineer incharge (SECOND FLOOR)
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.1 Page No. 367 (GROUND FLOOR )
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.1 Page No. 367 ( FIRST FLOOR )
Providing internal cement plaster 6 mm thick in a single coat in cement mortar 1:3 without neeru finish to concrete surface in all positions including scaffolding and curing etc. complete. Spec. No. Bd.L.1 Page No. 367 (SECOND FLOOR)
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 (GROUND FLOOR )
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 ( FIRST FLOOR )
Providing internal cement plaster 12mm thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complet. Spec. No. Bd.L. 2 Page No. 368 ( SECOND FLOOR )
Providing and applying Two coats of wall care Putty on plastered surface and ceiling and walls to prepare surface even and smooth of approved make, etc complete. Spec. No As director by engineer incharge. (GROUND FLOOR )
Providing and applying Two coats of wall care Putty on plastered surface and ceiling and walls to prepare surface even and smooth of approved make, etc complete. Spec. No As director by engineer incharge. ( FIRST FLOOR )
Providing and applying Two coats of wall care Putty on plastered surface and ceiling and walls to prepare surface even and smooth of approved make, etc complete. Spec. No As director by engineer incharge. ( SECOND FLOOR )
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Spec. No As director by engineer incharge.( FIRST FLOOR )
Providing fine cement finish 1.5 mm thick over green plaster surface including scaffolding curing etc. complete. Spec. No As director by engineer incharge. ( SECOND FLOOR )
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Spec. No As director by engineer incharge. ( GROUND FLOOR )
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and applying gypsum plaster ( with Gypsum material of Gypsum India / Mega Sign or equivalent make ) with finishing with gypsum material in 10 to 13 millimeter thickness to previously plastered surface / or on newly brick surface ( Excluding rough cast plaster ) in all position including preparing and Finishing the surface scaffolding etc.complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. ( GROUND FLOOR )
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369. ( FIRST FLOOR )
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1 kg per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. Spec . No. Bd. L.7 Page No.369 (SECOND FLOOR)
Providing and applying spray plaster made with finely graded marble and quartz in 2mm thickness in two coats using putty knife ort rowel to newly plaster fairly even surface after minimum 30 days gap in all position including finishing the surface using zero number sand paper or fine emry paper gently level the area by moving paper in round circles removing the dust and clean the surface with dry cloth and scaffolding including all materials and labour etc. complete. Spec. No As director by engineer incharge. ( GROUND FLOOR )
Providing and applying spray plaster made with finely graded marble and quartz in 2mm thickness in two coats using putty knife ort rowel to newly plaster fairly even surface after minimum 30 days gap in all position including finishing the surface using zero number sand paper or fine emry paper gently level the area by moving paper in round circles removing the dust and clean the surface with dry cloth and scaffolding including all materials and labour etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and applying spray plaster made with finely graded marble and quartz in 2mm thickness in two coats using putty knife ort rowel to newly plaster fairly even surface after minimum 30 days gap in all position including finishing the surface using zero number sand paper or fine emry paper gently level the area by moving paper in round circles removing the dust and clean the surface with dry cloth and scaffolding including all materials and labour etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR )
Providing Silica plaster plaster externally in two coats in all positions including base coat of 8 to 10 mm thick curing the same for not lessthan two days and keeping the surface of base coat rough to receive the final coat treatment 5 to 7 mm thick .finishing the surface by taking out grains and curing for 8 to 10 daysscaffolding etc complete.(The silica plast material shall contain 53 grade OPC cement with pozzolanic materials .size of agreegates shall be of 3 mm having 1:3 proportion with cement.. Spec. No As director by engineer incharge. ( GROUND FLOOR )
Providing Silica plaster plaster externally in two coats in all positions including base coat of 8 to 10 mm thick curing the same for not lessthan two days and keeping the surface of base coat rough to receive the final coat treatment 5 to 7 mm thick .finishing the surface by taking out grains and curing for 8 to 10 daysscaffolding etc complete.(The silica plast material shall contain 53 grade OPC cement with pozzolanic materials .size of agreegates shall be of 3 mm having 1:3 proportion with cement.. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing Silica plaster plaster externally in two coats in all positions including base coat of 8 to 10 mm thick curing the same for not lessthan two days and keeping the surface of base coat rough to receive the final coat treatment 5 to 7 mm thick .finishing the surface by taking out grains and curing for 8 to 10 daysscaffolding etc complete.(The silica plast material shall contain 53 grade OPC cement with pozzolanic materials .size of agreegates shall be of 3 mm having 1:3 proportion with cement.. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec. No As director by engineer incharge. ( GROUND FLOOR )
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at the junction of R.C.C members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete /B.B.masonry and or tying by binding wire etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning et c. complete. Spec. No .BDM-22, Page No. 390 ( GROUND FLOOR )
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning et c. complete. Spec. No .BDM-22, Page No. 390 (FIRST FLOOR)
Providing and laying machine cut machine polished machine cut Kota stone slabs 20 to 25 mm thick for treads and risers of steps and staircases, with rounded nosing for the treads on a bed of 1:4 cement mortar including cement float, filling joints with neat cement slurry, curing, polishing and cleaning et c. complete. Spec. No .BDM-22, Page No. 390 (SECOND FLOOR)
Providing and laying machine cut machine polished kota stone flooring 25 mm to 30 mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Spec. No. Bd.M.3 Page No. 380 ( GROUND FLOOR )
Providing and laying machine cut machine polished kota stone flooring 25 mm to 30 mm thick and required width in plain/ diamond pattern on bed of 1:6 C. M. including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. Spec. No. Bd.M.3 Page No. 380 (FIRST FLOOR)
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Spec. No. As directed by Engineer in Charge ( GROUND FLOOR )
Providing and fixing in required position skirting or dado of polished Kotah Stone slab 25 mm to 30 mm thick fixed on base on plaster of cement mortar 1:4 including cement float, filling joints with cement slurry, curing rubbing, polishing and cleaning complete. Spec. No. As directed by Engineer in Charge (FIRST FLOOR)
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. ( GROUND FLOOR )
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. (FIRST FLOOR)
Providing and laying vitrified matt fininsh tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. (SECOND FLOOR)
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. ( GROUND FLOOR )
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. (FIRST FLOOR)
Providing and laying vitrified matt finish tiles having size 590 mm to 605 mm x to 605 mm of 8 to 10 mm thickness and confirming IS. 15622-2006 (Group Bla) of approved make, shade and pattern for dado and skirting in required position fixed in 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. (SECOND FLOOR)
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec. No. Bd.M.12 Page No. 385. ( GROUND FLOOR )
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec. No. Bd.M.12 Page No. 385. (FIRST FLOOR)
Providing and laying vitrified mirror / glossy finish tiles decorative type having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete. a) Flooring Spec. No. Bd.M.12 Page No. 385. (SECOND FLOOR)
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting Spec. No. Bd.M.12 Page No. 385. ( GROUND FLOOR )
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting Spec. No. Bd.M.12 Page No. 385. (FIRST FLOOR)
Providing and laying vitrified mirror / glossy finish tiles having size 590 mm to 605 mm x 590 mm to 605 mm of 8 to 10 mm thickness and confirming to IS. 15622-2006 ( group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and clearing etc. complete.b) Skirting Spec. No. Bd.M.12 Page No. 385. (SECOND FLOOR)
Providing and fixing 1.5 mm thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete Spec. No. Bd.M.35C / Page No. 393 (GROUND FLOOR)
Providing and fixing 1.5 mm thick polyvenyl venyl chloride flooring including leveling the base with white cement including pasting with appropriate material cleaning the surface etc. complete Spec. No. Bd.M.35C / Page No. 393 (FIRST FLOOR)
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. a) Flooring. Spec. No. Bd. M-12 page No. 385 ( GROUND FLOOR )
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. a) Flooring. Spec. No. Bd. M-12 page No. 385 (FIRST FLOOR)
Providing and laying chequered tiles of approved quality of size 30 cm x 30 cm, confirming to corresponding I.S. for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. a) Flooring. Spec. No. Bd. M-12 page No. 385 (SECOND FLOOR)
Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Spec. No. Bd.M. 12 Page No. 385. ( GROUND FLOOR )
Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Spec. No. Bd.M. 12 Page No. 385. ( FIRST FLOOR)
Providing and laying ceramic tiles of having size 30 cm x 30 cm confirming to I.S.15622/2006 (group D II-A) and 7 to 8 mm thick for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with white/colour cement slurry cleaning curing etc. complete. Spec. No. Bd.M. 12 Page No. 385. ( SECOND FLOOR )
Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. complete. Spec. No. Bd.M.13 Page No. 386. ( GROUND FLOOR )
Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. complete. Spec. No. Bd.M.13 Page No. 386. (FIRST FLOOR)
Providing and laying ceramic tiles having size 30 cm. x 60 cm. confirming to corresponding I.S. for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. complete. Spec. No. Bd.M.13 Page No. 386. (SECOND FLOOR)
Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One Side Polish. Spec. No. Bd.M.35 Page No.393. (GROUND FLOOR)
Providing 25 mm to 30 mm thick partition of polished black kadappa stone slab of approved quality including giving required size and shape etc. Fixing in cement mortar 1:3 curing and cement etc. complete. a) One Side Polish. Spec. No. Bd.M.35 Page No.393. (FIRST FLOOR)
Providing sills of required material 20 mm to 25 mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing, cleaning complete. b) Granite Spec. No. Spec.No.: Bd.M.31/Page No.393 (GROUND FLOOR)
Providing sills of required material 20 mm to 25 mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing, cleaning complete. b) Granite Spec. No. Spec.No.: Bd.M.31/Page No.393 ( FIRST FLOOR )
Providing sills of required material 20 mm to 25 mm thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, moulding edges, polishing, cleaning complete. b) Granite Spec. No. Spec.No.: Bd.M.31/Page No.393 (SECOND FLOOR)
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m). Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m). Spec. No As director by engineer incharge. ( FIRST FLOOR )
Providing and laying in position flooring of telephone black / Amba white / Cat bary brown / Ruby red / Ocean brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. (GROUND FLOOR)
Providing and laying in position flooring of telephone black / Amba white / Cat bary brown / Ruby red / Ocean brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. (FIRST FLOOR)
Providing and laying in position flooring of telephone black / Amba white / Cat bary brown / Ruby red / Ocean brown granite stone of approved shade and size 18 mm to 20 mm thick on bed 1:6 cement mortar including cement floats striking joints, pointing in C.M. 1:3 curing and cleaning etc. complete. (SECOND FLOOR)
Providing and fixing machine cut machine polished 18 to 20 mm thick telephone black / amba white / cat bary brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.. Spec. No .Bd. M.22 B Page No. 390 (GROUND FLOOR)
Providing and fixing machine cut machine polished 18 to 20 mm thick telephone black / amba white / cat bary brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.. Spec. No .Bd. M.22 B Page No. 390 (FIRST FLOOR)
Providing and fixing machine cut machine polished 18 to 20 mm thick telephone black / amba white / cat bary brown / RBI red / ocean brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete.. Spec. No .Bd. M.22 B Page No. 390 (SECOND FLOOR)
Providing and laying telephone black / amba white / cadburybrown / ruby red / Ocean brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and laying telephone black / amba white / cadburybrown / ruby red / Ocean brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and laying telephone black / amba white / cadburybrown / ruby red / Ocean brown granite stone of 18 to 20 mm thick for door frame/ dado/ window boxing etc. On C.M. 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Hand polishing to dado, skirting including cleaning, washing etc. complete. Spec. No As director by engineer incharge.
Hand polishing to dado, skirting including cleaning, washing etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Hand polishing to dado, skirting including cleaning, washing etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and laying 18 mm thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 mm (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etccomplete. The application rate for tile adhesives shall be as per manufacturer's recommendations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) Flooring. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and laying 18 mm thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 mm (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etccomplete. The application rate for tile adhesives shall be as per manufacturer's recommendations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) Flooring. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and laying 18 mm thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 mm (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etc complete. The application rate for tile adhesives shall be as per manufacturer's recommendations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) Skirting. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and laying 18 mm thick ADONI BROWN LEATHER FINISH stone for flooring, machine cut in required size, approved shade, color and texture laid using white cement slurry over 20 mm (average) thick base of cement mortar 1:4 followed by laying, fixing and jointed with white cement slurry mixed with matching pigment, including rubbing and curing moulding and polishing to edge to give high gloss finish etc complete. The application rate for tile adhesives shall be as per manufacturer's recommendations. as per detail drawing. The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels and as directed by Engineer in charge. Complete. a) Skirting. Spec. No As director by engineer incharge. (FIRST FLOOR)
Bamboowood 14 mm thick Tile Flooring including quarter round & door reducer - Providing & fixing in position Phenol bonded Epitome Bamboowood flooring with planks of sizes 14mm thick, 1800mm length (minimum) and 130mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocaking system, with 2mm underlay as sound abrobing and moisture barrier and underlayment of 4mm thick expanded poly ethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and dorr reducer of size 1900mm x 44mm, wherever required. The Epitome Bamboowood planks shall have minimum density of 1000 kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge.Spec. No As director by engineer incharge. (GROUND FLOOR)
Bamboowood 14 mm thick Tile Flooring including quarter round & door reducer - Providing & fixing in position Phenol bonded Epitome Bamboowood flooring with planks of sizes 14mm thick, 1800mm length (minimum) and 130mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocaking system, with 2mm underlay as sound abrobing and moisture barrier and underlayment of 4mm thick expanded poly ethylene foam sheets having density 40kg/cum, over prepared surface with necessary quarter round planks of size 1900mm x 18mm and dorr reducer of size 1900mm x 44mm, wherever required. The Epitome Bamboowood planks shall have minimum density of 1000 kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge.Spec. No As director by engineer incharge. (FIRST FLOOR)
Bamboowood 14mm thick wall Skirting - Providing & fixing in position Phenol bonded Epitome Bamboowood in wall skirting with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). The skirting shall be fixed SS screws & rawl plugs, over underlayment of 4mm thick expanded poly ethylene foam sheets having density 40kg/cum, over prepared surface. The Epitome Bamboowood planks shall have minimum density 1000 kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge (GROUND FLOOR)
Bamboowood 14mm thick wall Skirting - Providing & fixing in position Phenol bonded Epitome Bamboowood in wall skirting with planks of sizes 14mm thick, 1900mm length (minimum) and 85mm wide (minimum), in approved colour, texture and finish, having Performance Appraisal Certificate (PAC) issued by Building materials & Technology Promotion Council (BMTPC). The skirting shall be fixed SS screws & rawl plugs, over underlayment of 4mm thick expanded poly ethylene foam sheets having density 40kg/cum, over prepared surface. The Epitome Bamboowood planks shall have minimum density 1000 kg/cum & minimum Hardness 1000 Kgf. with Eco friendly UV coating, all complete as per direction of Engineer in-charge (FIRST FLOOR)
Providing and Laying factory made coloured chamfered edge Cement concrete grass paver blocks of required strength,thickness & size / shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of fine fine aggregate (natural sand / crushed sand VSI grade finely washed etc.), compacting and proper embedding/laying of inter locking paver blocks into the fine aggregate (natural sand/crushed sand VSI grade finelywashed etc.) bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and cutting of paver blocks as per required size and pattern, finishing and sweeping extra fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) and complete as per manufacturer spsecifications & direction of Engineer-in-Charge. 60mm thick CC paver block of M-35 grade concrete with approved colour and design & pattern.. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing heavy duty inter locking concrete Graypaving blocks of 60 mm thickness of having a strength of 300 kg/Sq.cm. of approved quality and shape on a bed of crushed sand of 25 to 30 mm thick including skirting joints and cleaning etc. complete.
Providing and casting in situ or precast tapering R. C. C. M20 Mountable type kerb without gutter (as per IRC 86 1983) embedded 125mm below ground level over M10 PCC finished neatly with C.M. 1:2, setting the same in C.M. 1:2, including the required excavation in any strata and removing the excavated stuff any where in city and redoing the surface as specified and directed by Engineering Incharge. Using Concrete Batching and Mixing Plant Spec. No. MORTH 408
Providing,aupplying, fabricating and fixing panel of aluminium composite panel cladding in approved shape made out of 4 mm thick ACP sheet material consisting of 3mm thick FR grade mineral core following NBC part IV Fire and life safety (having 2 hours fire resistance in accordance to ASTM E119-12 and BS476 part 6 and 7 class O) sandwitched between two aluminium sheets (each 0.5 mm thick of AA 5005/AA3105 grade) The aluminium composite panel cladding sheet shall be coil coated with kynar 500 based PVDF/Lumiflon based fluropolymer resin (having 70:30 ratio of PVDF and acrylic) coating of approved colour and sg=hade on top face and polymer (service) coating of bottom face as specified using stainless steel screws,nuts,bolts,washers,cleats,weather silicon sealent,backer rods etc .overall weight of the ACP shall not be less than 7.5 kg/sqm) (FIRST FLOOR)
Providing and Fixing Sun Louvre panels roll formed, 0.6 mm thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineerin Charge. (GROUND FLOOR)
Providing and Fixing Sun Louvre panels roll formed, 0.6 mm thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineerin Charge. (FIRST FLOOR)
Providing and Fixing Sun Louvre panels roll formed, 0.6 mm thick, pre-painted stove enameled aluminium strip of a corrosion resistant alloy, including necessary fitting etc. complete, as directed by Engineerin Charge. (SECOND FLOOR)
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.Spec. No. Bd.C.2 Page No. 275 (GROUND FLOOR )
Providing and fabricating structural steel work in rolled sections like joists, channels, angles, tees etc. as per detailed design and drawings or as directed including cutting, fabricating, hoisting, erecting, fixing in position making riveted / bolted /welded connections without connecting plates, braces etc. and including one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade etc. complete.Spec. No. Bd.C.2 Page No. 275 (SECOND FLOOR)
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. No. : As directed by Engineer-in-charge.. Spec. No. B-18 Page No. 78 (GROUND FLOOR)
Providing, fabricating and erecting at site of work the tubular steel structure (shed) as per standard design and specifications having various spans in between trusses and in multiples of standard length of bays as specified as per standard specifications, inclusive of cost of steel tubular trusses, tubular columns purlins, tie runners, foundation bolts, base plates, nuts and bolts, welding wherever required etc. as per detailed drawing inclusive of one coat of anticorrosive paint and two coats of oil painting of approved quality and shade etc. complete. Spec. No. : As directed by Engineer-in-charge.. Spec. No. B-18 Page No. 78 (FIRST FLOOR)
Providing and fixing corrugated galvanised iron sheets of 0.63mm thick (24 B.W.G.) for roofing without wind tiles including fastening with galvanised iron screws and bolts, lead and bitumen washers asper drawing etc. complete. (Weight of 5.5 kg/sq.m.)
Supply and Installation of transluc entro of with DPIF luxs tanding seam multi cell polycarbonate panel system. The system with complete assembly of coextruded UV protected multicell panels in corporate din toa complete system.Co-extruded UV protected polycarbonate panel system of min12 mm thick of 900mm(min.) width with angular day lighting concept. Panels shall have minimum sixla yers with truss bridge design for higher flexibility & strength. Panels with all fixing accessories to ensure best performance for winduplift, vibration, oil canning and visual appearance Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double toothgrip lock locking mechanism and will be secured on MS structure (will be paid Separately) with 3 Number self-drilling screws & trapezoid SS fasteners holding the base of the standing seam offering best stability having a pull-outload of min. 7000N(7KN) test ed as per ISO6892:1998 and IS1608:2005, as per design requirement. Panels must satisfy Dart drop impact test as per IS14443-97 shall shown osign of breakage on Polycarbonate sheets which have been exposed to UV foramin. of 500 Hoursasper ASTMG155. Panels shall not have Yellow ness Index as per ASTMD 1925 of 15 units when tested on a sample exposed to UV for 500 Hours as per ASTMG 155. U value shall not be more than 1.6W/m2 K as per ENISO10077-2:2018. Panel shall be with additional End cap/ AluminiumU/ Fprofile/ Glazing Bar for ends as required. Panel shall be fixed over MS structural steel/ MS purlin(paidseparately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Day light in gor approved equivalent The 12 mm thick panels shall be used for a roofing height of upto 15 mtrs. SECOND FLOOR
Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing frame with / without ventilator of size as specified with country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300mm x 40mm x 5mm with oil painting, etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR )
Solid Core Flush door Single leaf :- Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without Spec. No As director by engineer incharge.(GROUND FLOOR)
Solid Core Flush door Single leaf :- Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without Spec. No As director by engineer incharge. (FIRST FLOOR)
Solid Core Flush door Single leaf :- Providing and fixing factory made solid core flush door in single leaf 35 mm thick, decorative types, of exterior grade, as per detailed drawings, conforming to I.S.:2202 - 1962 (Revised) with approved face veneers on both faces with/without glazing and venetians in the positions shown on the drawings or as directed, all necessary beads, moulding and lipping, holdfasts, mat finish stainless steel fixtures fastenings , finishing with french-polish/ waxing complete. (without Spec. No As director by engineer incharge. (SECOND FLOOR)
Solid Core Flush door Double leaf :- Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter Spec. No As director by engineer incharge. (GROUND FLOOR)
Solid Core Flush door Double leaf :- Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter Spec. No As director by engineer incharge. ( FIRST FLOOR )
Solid Core Flush door Double leaf :- Providing and fixing factory made solid core flush door shutters in double leaves 35mm thick,decorative type of exterior grade, as per detailed drawings, conforming to I.S.: 2202 – 1966 (Revised) including approved face veneers on both sides, without glazing and venetians including mat finish stainless steel fixtures and fastening, stoppers and finishing with french polishing etc. (Excluding door frame)(Sample to be got approved from Ex. Engineer before use) Commercial Hard Wood shutter Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc comple. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc comple. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing fiber glass reinforced polyster door shutter 30 mm thick as per IS 14856 (2000) (Reaffirmed 2006) without ventilator including chromium plated fixtures and fastening with chromium plated handles on both sides, etc comple. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing collapsible steel gate in one / two leaves with hot rolled vertical channels of 18 x 9 x 3 mm minimum size, crossings of M.S. flats of size 18 x 5 mm T or E section for runner of minimum 40 x 6 mm size for flange, M.S. flat for top runner of minimum size 40 x 12 mm with roller wheels confirming to grade F.G. 150 fitted with snap headed rivets of minimum size 6 mm max. spacing of vertical channels be 100 mm enclosed gate position and clear space of 150 mm between two sets of crossings with hold fasts, stoppers, spaces, handles, locking arrangement and one coat of red lead primer and oil painting etc. complete. (I.S. 105211983). Spec. No. Bd.T. 57 Page No.511. (GROUND FLOOR)
Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of,high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (With mechanical gear). As directed by Engineer in charge. (GROUND FLOOR)
a) Door Frame: Providing Frames for Lead Lined door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets being overlapped from either side, spray quoted with 2 coats of Enamel paint after one coat of white wood primer of minimum 200 micron etc. complete as per direction of Engineer in Charge. with prior approval of concerned Superitending Engineer. (GROUND FLOOR)
a) Door Frame: Providing Frames for Lead Lined door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets being overlapped from either side, spray quoted with 2 coats of Enamel paint after one coat of white wood primer of minimum 200 micron etc. complete as per direction of Engineer in Charge. with prior approval of concerned Superitending Engineer. (FIRST FLOOR)
a) Door Frame: Providing Frames for Lead Lined door shutters 1st class Malaysian Hardwood Frame densified and pressure treated with fire retardant chemicals in vacuum impregnation vessel under 160 PSI pressure as per IS:401 and kiln seasoned to moisture below 15% as per IS:1141 of section 120 X 70 mm with 45mm thick two layered 3mm Lead Line Sheets being overlapped from either side, spray quoted with 2 coats of Enamel paint after one coat of white wood primer of minimum 200 micron etc. complete as per direction of Engineer in Charge. with prior approval of concerned Superitending Engineer. (SECOND FLOOR)
b) Shutter: Supplying of 'TUFWUD' brand 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type). 32mm Wooden structure of 1st class Hardwood or Pinewood of at least 50mm width, top and bottom rails of 75mm width, with filler material without any gap of 1st Class Hardwood, or pine wood, all chemically treated for termite and borer resistance as per IS 401:2001 under minimum 150 PSI pressure, and seasoned as per IS 1141: 1993 upto desired moisture level as per IS 287, with one side 3mm HDF & other side 3mm lead & 6mm BWP ply; all hot-pressed with Phenol Formaldehyde resin, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of enamel paint of minimum 300 micron. with prior approval of concerned Superitending Engineer.(GROUND FLOOR)
b) Shutter: Supplying of 'TUFWUD' brand 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type). 32mm Wooden structure of 1st class Hardwood or Pinewood of at least 50mm width, top and bottom rails of 75mm width, with filler material without any gap of 1st Class Hardwood, or pine wood, all chemically treated for termite and borer resistance as per IS 401:2001 under minimum 150 PSI pressure, and seasoned as per IS 1141: 1993 upto desired moisture level as per IS 287, with one side 3mm HDF & other side 3mm lead & 6mm BWP ply; all hot-pressed with Phenol Formaldehyde resin, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of enamel paint of minimum 300 micron. with prior approval of concerned Superitending Engineer.(FIRST FLOOR)
b) Shutter: Supplying of 'TUFWUD' brand 44mm Solid core flush door shutters conforming to the I.S. specification 2202-1991 (specification for wooden flush door shutter – solid core type). 32mm Wooden structure of 1st class Hardwood or Pinewood of at least 50mm width, top and bottom rails of 75mm width, with filler material without any gap of 1st Class Hardwood, or pine wood, all chemically treated for termite and borer resistance as per IS 401:2001 under minimum 150 PSI pressure, and seasoned as per IS 1141: 1993 upto desired moisture level as per IS 287, with one side 3mm HDF & other side 3mm lead & 6mm BWP ply; all hot-pressed with Phenol Formaldehyde resin, internally lipped with hardwood beading, and pasted in Hydraulic Press under 50 tonnes pressure, spray quoted with 2 coats of enamel paint of minimum 300 micron. with prior approval of concerned Superitending Engineer.(SECOND FLOOR )
Supplying and fixing inposition Aluminium four track sliding windows withouter framemade from section of overall size 122 mmx45 mm, bottom section with drain section track weighing 1.83 Kilogram permetre and to pand side section of size 122x31.75mm weighing 1.15 Kilogram per running metre with shutter sections made of 18mmx40mm size havingave rage weight of 0.6 Kilogram perrunning metre (oras required size ) with change in proportionate weight, with 6mm float glassin three equalpanels and alluminium coated stainless steel mosquitonet in one(2/3ofopening)panel fixed with new neoprene gasket, shutters to be provided with nylonen cased stainlesssteel rollers, necessary locks and handles complete. a) Colour anodized (GROUND FLOOR)
Supplying and fixing inposition Aluminium four track sliding windows withouter framemade from section of overall size 122 mmx45 mm, bottom section with drain section track weighing 1.83 Kilogram permetre and to pand side section of size 122x31.75mm weighing 1.15 Kilogram per running metre with shutter sections made of 18mmx40mm size havingave rage weight of 0.6 Kilogram perrunning metre (oras required size ) with change in proportionate weight, with 6mm float glassin three equalpanels and alluminium coated stainless steel mosquitonet in one(2/3ofopening)panel fixed with new neoprene gasket, shutters to be provided with nylonen cased stainlesssteel rollers, necessary locks and handles complete. a) Colour anodized (FIRST FLOOR)
Supplying and fixing inposition Aluminium four track sliding windows withouter framemade from section of overall size 122 mmx45 mm, bottom section with drain section track weighing 1.83 Kilogram permetre and to pand side section of size 122x31.75mm weighing 1.15 Kilogram per running metre with shutter sections made of 18mmx40mm size havingave rage weight of 0.6 Kilogram perrunning metre (oras required size ) with change in proportionate weight, with 6mm float glassin three equalpanels and alluminium coated stainless steel mosquitonet in one(2/3ofopening)panel fixed with new neoprene gasket, shutters to be provided with nylonen cased stainlesssteel rollers, necessary locks and handles complete. a) Colour anodized (SECOND FLOOR)
Providing and fixing in position U.P.V.C. (Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section ( 73 x 50 ) mm with an outer wall thickness of 2 mm & steel reinforcement, multi-chambered slider frame ( 73 x 60 ) mm with steel reinforcement, multi-chambered slider sash ( 46 x 82 ) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets, silicon sealent, sliding handle, fixture sandfastenings (couplings, hinges ) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer - In- Charge etc.complete (GROUND FLOOR)
Providing and fixing in position U.P.V.C. (Unplasticized Poly Vinyl Chloride) having multi-chambered outer frame section ( 73 x 50 ) mm with an outer wall thickness of 2 mm & steel reinforcement, multi-chambered slider frame ( 73 x 60 ) mm with steel reinforcement, multi-chambered slider sash ( 46 x 82 ) mm with steel reinforcement designed to give optimum strength, 5 mm thick toughened double glass with 12 mm spacer of good quality including alluminium track, Inter-locking profile, coextruded beadings, EPDM gaskets, silicon sealent, sliding handle, fixture sandfastenings (couplings, hinges ) including with all required screws and nuts with all necessary U.P.V.C. sections as per the detailed drawing and as directed by Engineer - In- Charge etc.complete ( FIRST FLOOR )
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 mm x 1.22 mm box type, 5 mm thick sheet glass louvers, of approved quality etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing aluminium grill diamond mesh type DG 202 of 7.5 mm thick including fixing in position anodised aluminium frame section of 80 x 38 mm x 1.22 mm size box, cutting to the required size with all wastage , labour, lead lift etc. complete. Spec. No As director by engineer incharge.
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec. No. Bd.U.1 Page No. 537 ( Ground Floor )
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec. No. Bd.U.1 Page No. 537 (FIRST FLOOR)
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kg/sqm as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. Spec. No. Bd.U.1 Page No. 537 (SECOND FLOOR)
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and1.5mm thick vertical supports spaced at 1.5m center to center and8mm thick toughened glass including fabricating ,fixtures, errecting necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete ( Ground Floor )
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and1.5mm thick vertical supports spaced at 1.5m center to center and8mm thick toughened glass including fabricating ,fixtures, errecting necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete (FIRST FLOOR)
Providing and fixing 900mm high S.S.304 Grade Stainless steel railing with 40mm diameter and 1.5mm thick at top,40mm diameter and1.5mm thick vertical supports spaced at 1.5m center to center and8mm thick toughened glass including fabricating ,fixtures, errecting necessary welding , grinding , finishing, buffing to stainless steel pipe etc. complete (SECOND FLOOR)
Providing and fixing 50 mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating, fixtures, errecting, necessary welding, grinding ,finishing, buffing to stainless steel pipe etc.complete ( Ground Floor )
Providing and fixing 50 mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating, fixtures, errecting, necessary welding, grinding ,finishing, buffing to stainless steel pipe etc.complete (FIRST FLOOR)
Providing and fixing 50 mm diameter and 1.5 mm thick Stainless steel hand railing in S.S.304 Grade including fabricating, fixtures, errecting, necessary welding, grinding ,finishing, buffing to stainless steel pipe etc.complete (SECOND FLOOR)
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 Kilo gram capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete Spec as directed by engineer in charge. ( Ground Floor )
Providing and fixing in position, Double shuttered aluminium extruded powder coated openable door of specified size with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , heavy duty, Hydraulic floor spring of 150 Kilo gram capacity , having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length aluminium tower bolts, 150mm dia. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc.complete Spec as directed by engineer in charge. (FIRST FLOOR)
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR )
Providing and fixing in position, Single shuttered aluminium extruded powder coated openable door of overall size 0.90 m x 2.40 m with aluminium door frame of powder coated section 101.60 x 44.75mm , 3.18 mm thick and shutter comprising of powder coated section having bottom and lock rail of size 150 mm x 44.5 mm x 3.00 mm thick top rails 47.62 x 44.45 mm x 3.00 mm thick , vertical style 47.62 x 44.45 mm, 3.00 mm thick and for shutter plain glass panes 5 mm thick for top panels and 12mm thick both side laminated phenol bonded particle board panels for bottom panels etc. , I.S.I. mark , with bijagiri having heavy duty concealed lock, necessary beading, glazing clips, PVC gaskets, 250mm length tower bolts, 150mm diam. pad handle, etc. as per detailed design and drawing or as directed by engineer in charge including all materials , labours, and equipment etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing in position extruded aluminium partitions having frame made out of extruded tubular section of size 65mm x 40mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 12923 1990 , laminated on both sides, Nova teak or equivalent with aluminium glazing clips of size 12 mm x 12 mm (conical) as per drawing etc. complete. Spec as directed by engineer in charge. ( Ground Floor )
Providing and fixing in position extruded aluminium partitions having frame made out of extruded tubular section of size 65mm x 40mm with 12 mm thick three layered flat pressed teak wood particle board bonded with BWP type exterior grade phenol formaldehyde synthetic resin conforming to IS 12923 1990 , laminated on both sides, Nova teak or equivalent with aluminium glazing clips of size 12 mm x 12 mm (conical) as per drawing etc. complete. Spec as directed by engineer in charge. (FIRST FLOOR)
Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc.complete. Spec. No As director by engineer incharge.( Ground Floor )
Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc.complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing in position after hoisting, precast 1:2 cement mortar reinforced jali 80 mm thick with 3 mm diameter mild steel bar reinforcement, of approved design on both sides, fixing in cement mortar 1:3 and curing etc.complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Spec. No As director by engineer incharge. ( Ground Floor )
Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and applying two coats Apex Ultima Puranature Anti- Pollution Or equivalent approved brand, paint should decomposes organic substances and inorganic gases(NOx, VOC’s, CO, SOx, formaldehydes, etc.) in presence of natural or artificial light. It contains Graphene and nanoparticles of titanium oxide. and Absorbs CO2 (4.8 kg/15 l). plaster crack should be filled by Acrylic base Crack seal/Textured Crack filler, Paint has to applied on one coat of Apex Ultima Puranature Anti-Pollution Primer or Equivalent. Warranty Should be given by the Manufaturer The work should be done by the Manufacturer Recommended applicator and he should be able to furnish stage wise onsite technical reports from the concerned company technologist. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and applying priming coat on concrete/ masonary / asbestos cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and applying Texture plaster with finishing with PurliDeleted / Rustic texture material ( with texture material of Asian / Renava / Nitco/Temtex or equivalent company make ) in 3 to 4 millimeter thickness on previously finished plastered surface ,including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface scaffolding etc.complete. (GROUND FLOOR)
Providing and applying Texture plaster with finishing with PurliDeleted / Rustic texture material ( with texture material of Asian / Renava / Nitco/Temtex or equivalent company make ) in 3 to 4 millimeter thickness on previously finished plastered surface ,including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface scaffolding etc.complete. (FIRST FLOOR)
Providing and applying Texture plaster with finishing with PurliDeleted / Rustic texture material ( with texture material of Asian / Renava / Nitco/Temtex or equivalent company make ) in 3 to 4 millimeter thickness on previously finished plastered surface ,including Plaster Groove 6mm thickness or Tape Grooves 35 to 45 mm thickness or as required, in all position including preparing the surface scaffolding etc.complete. (SECOND FLOOR)
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge. (GROUND FLOOR)
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge.(FIRST FLOOR)
Providing and applying 2 Coats of 100% Pure acrylic water based paint with special heat reflectance property to withstand the harsh climate for period of atleast 10 years of approved make. Paint system should provide durable and long lasting finish with DFT of min 90 microns and should protect against concrete carbonation with R value of minimum 600 and equivalent concrete layer thickness value of min 150 cm. Paint should have breathability property and should be able to cover hairline cracks in the surface upto 0.5mm The paint has to be applied on a coat of high quality acrylic copolymer based alkali resistant primer with excellent penetrating properties including cleaning, with all leads and lifts at all levels etc complete, as directed by Engineer in charge. (SECOND FLOOR)
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge.(GROUND FLOOR )
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. (FIRST FLOOR)
Providing and applying 2 coats of 100% Pure acrylic low VOC and APEO & HCHO free water based paint of approved colour that belongs to class 1 flame spread resistance of approved make Paint should provide durable and long lasting silk finish with a high crack tolerance of upto 1mm. Paint should have an oustanding washability with high resistance to wide range of bacteria and fungus. Paint has to be applied on smooth and uniform surface prepared by an acrylic copolymer low VOC & Odour putty. This surface should be primed with water based low VOC Primer. The work activity should cover all aspects of applying paints from surface preparation as directed by Engineer in charge. (SECOND FLOOR)
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge.FIRST FLOOR
Providing and applying two coats of High Albedo paint having minimum Solar Reflective Index (SRI) 108 (with solar reflectance & thermal emittance tested as per ASTM) C 1549 and ASTM C 1371 respectively, VOC less than 10 cc/gm. The coating thickness and the methodology of application shall strctly as per manufacturer's specifitions and as approved by engineer in charge. Surface preparation includes cleaning with metal wire brush to remove all dust, fungus etc, washing with water all complete.The contractor shall give guarantee for the performance of SRI and also the durabitity of coating, all complete as per direction of Engineer - in- incharge. (SECOND FLOOR)
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Spec. No. Bd.O.5 Page No.405. (GROUND FLOOR)
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Spec. No. Bd.O.5 Page No.405. (FIRST FLOOR)
Providing and applying two coats of synthetic enamel paint of approved colour to new /old structural steel work and wood work in buildings, including scaffolding if necessary, cleaning and preparing the surface (excluding primer coat) etc. complete. Spec. No. Bd.O.5 Page No.405. (SECOND FLOOR)
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary.(GROUND FLOOR)
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. (FIRST FLOOR)
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. (SECOND FLOOR)
Providing & laying waterproof treatment of terrace slab with B.B. Coba in all position with an average thickness of 150 mm consisting specialised materials as per the manufactures specifications and covering 10 years guarantee on court fee stamp paper including all lead, lift, etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing & laying waterproof treatment of terrace slab with B.B. Coba in all position with an average thickness of 150 mm consisting specialised materials as per the manufactures specifications and covering 10 years guarantee on court fee stamp paper including all lead, lift, etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with aterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete.(GROUND FLOOR)
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with aterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. (FIRST FLOOR)
Providing waterproofing in W.C. and bath including brick bat coba in all position including providing and laying 12mm bedding in cement mortor 1:3 on vergin concrete slab with waterproofing compound @ 1kg/per bag of cement laying brick bat coba of required thickness in cm 1:5 with aterproofing compound 1 kg/bag of cement grouting and finishing the top layer with 20mm thick brick bedding in cm mortor 1:3 with waterproofing compound 1 kg/per bag of cement and testing the treated portion for 48 hours by pond test and covering ten years' guarantee on requisite stamp paper including curing etc. complete. (SECOND FLOOR)
Providing and fixing 20 to 25 mm thick rough shahabad box type waterproofing treatment to vertical outside faces of Reinforced cement concrete walls of basement or underground floor including filling the gap of 25 mm between rough shahabad and R.C.C. walls with cement grout mixed with water proofing liquid Algae proof or other alike with one tile lift method, brushing the joints horizontally with cement slurry mixed with water proofing liquid for width 30 to 35 mm and sloping coping over topmost tile with cement mortar 1:3, butting the bottom most with Cement concrete 1:2:4 mixed with water proofing liquid, curing, with 7 years guarantee on court fee stamp of Rs.100/with ponding test etc complete. (Excluding Cement Concrete 1:3:6 Base Concrete ) Spec .No. Bd. J.2 Page No. 355
Providing and fixing false ceiling of 12mm thick as per drawings including powder coated G.I. wall angle of 20mm x 20mm size, G.I. grid runners of size 20mm x 38mm at 600mm center to center both ways and suspended using G.I. 3mm wire including fixing using butterfly clips and fasteners including transporting, scaffolding all necessary labour and machinery, finishing etc. complete. Spec. No. As directed by Engineer in charge (GROUND FLOOR)
Providing and fixing false ceiling of 12mm thick as per drawings including powder coated G.I. wall angle of 20mm x 20mm size, G.I. grid runners of size 20mm x 38mm at 600mm center to center both ways and suspended using G.I. 3mm wire including fixing using butterfly clips and fasteners including transporting, scaffolding all necessary labour and machinery, finishing etc. complete. Spec. No. As directed by Engineer in charge (FIRST FLOOR)
Providing and fixing in position gypsum board false ceiling with 12.5mm thick gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Spec :As directed by Engineer in charge. (GROUND FLOOR)
Providing and fixing in position gypsum board false ceiling with 12.5mm thick gypsum boards, screwed/fixed to the under structure of suspended G.I. Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 mm maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. Spec :As directed by Engineer in charge. (FIRST FLOOR)
Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture spintone/cosmos/hexa or equivalent of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600 x 600 mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone / cosmos / hexa ) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed. with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins)e.Spec. No. As directed by Engineer in charge (GROUND FLOOR)
Providing and fixing 15 mm thick eco-friendly densified edge calcium silicate false ceiling of approved texture spintone/cosmos/hexa or equivalent of size 595mm x 595mm in true horizontal level, suspended on interlocking metal grid of hot dipped galvanized steel sections (galvanising at @12 gm/sq.m including both sides) consisting of main T runner suitably spaced at joints to get required length and size 24X38mm. made from 0.33mm thick(minimum ) sheet, spaced 1200mm center to center and cross T of size 24X28mm made of 0.33mm thick(minimum ) sheet to be interlocked at the middle of the 1200x600 mm panel to form the grid of size 600 x 600 mm resting on periphery walls/partitions on a perimeter wall angle precoated steel of size 24x24x3000 made of 0.4 mm thick (minimum) sheet with the help of all plugs at 450mm and laying 15 mm thick densified edges calcium silicate ceiling tiles of approved texture (spintone / cosmos / hexa ) in the grid, including light fittings , fixtures , smoke detectors etc., wherever required. Main T runners suspended from ceiling with using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling using 12.5mm dia. And 50mm long dash fasteners, 4mm G.I. adjustable rods with galvanized steel levels clips of size 85x30x0.8mm, spaced at 1200mm center to center along main T bottom exposed. with 24mm of all T-sections shall be prepainted with polyester baked paint, for all heights, as per specifications, drawings etc. complete.(currently this item should be used only for VIP cabins)e.Spec. No. As directed by Engineer in charge (FIRST FLOOR)
Acrylic tactile audio map Design, supply, fabrication and fixing of acrylic, non glare, tactile audio pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved colourand non glare acrylic cut out symbols and up per case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge. Spec. No As director by engineer incharge. (GROUND FLOOR)
Acrylic tactile audio map Design, supply, fabrication and fixing of acrylic, non glare, tactile audio pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved colourand non glare acrylic cut out symbols and up per case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Acrylic tactile audio map Design, supply, fabrication and fixing of acrylic, non glare, tactile audio pictorial building layout as per the approved size, design and make, having 6mm thick acrylic non glare base plate of the approved colourand non glare acrylic cut out symbols and up per case Sans Serif letters of 12mm height, raised 3mm above base plate and Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. The map to be installed at the specified location as per accessibility standards, shall be oriented to the position of the viewer and to be installed at a height of 800 mm from the finished ground/ floor level and using the necessary hardware specified by the manufacturer and to be installed up to the satisfaction of the engineer in charge. Spec. No As director by engineer incharge. (SECOND FLOOR)
Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the -engineer in charge. Spec. No As director by engineer incharge.(GROUND FLOOR )
Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the -engineer in charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Directional signage Design, supply, fabrication and fixing acrylic multilingual Braille (raised dots) directional signboards of size 6" x 9" designed as per accessibility standards and having 4mm thick acrylic base plate with Upper Case San Serif words made of white acrylic non glare cut out letters of height 15mm raised not less than 0.8mm above base plate and the equivalent word written in Hindi with Devnagri non glare acrylic letters of height 15mm raised not less than 0.8mm above base plate and having a non glare acrylic cut arrow pointing in the required direction. Each signboard to be fixed as per manufacturers specifications on the wall at the approved location and at a height of 1200mm from FFL and as per the directions by the -engineer in charge. Spec. No As director by engineer incharge.(SECOND FLOOR)
Floor Directories Providing and fixing acrylic multilingual Braille (raised dots) ADA compliant modular floor directories system on all floors of size1.5' x 2' , showing the floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letters of height 20mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200mm from FFL and as per the directions by the engineer in charge. from FFL and as per the directions by the engineer in charge. Spec. No As director by engineer incharge. (GROUND FLOOR )
Floor Directories Providing and fixing acrylic multilingual Braille (raised dots) ADA compliant modular floor directories system on all floors of size1.5' x 2' , showing the floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letters of height 20mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200mm from FFL and as per the directions by the engineer in charge. from FFL and as per the directions by the engineer in charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Floor Directories Providing and fixing acrylic multilingual Braille (raised dots) ADA compliant modular floor directories system on all floors of size1.5' x 2' , showing the floor plan and the list of rooms on that floor, to be installed on each floor near the staircase, designed as per standards and having 4mm thick blue acrylic base plate with Upper Case San Serif words and symbols made of white acrylic non glare cut out letters of height 20mm raised not less than 0.8mm above base plate and the equivalent word/s written in Hindi with Devnagri non glare imported acrylic letters of height 15mm raised not less than 0.8mm above base plate. Grade 2/ Grade 1 Braille to be integral with the sign face and be raised 0.5mm above base plate. Each directory to be fixed as per manufacturers specifications on the wall at the approved location at a height of 1200mm from FFL and as per the directions by the engineer in charge. from FFL and as per the directions by the engineer in charge. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing an ADA compliant Disability Service Desk having a lowered portion (800mm from FFL) and leg space of 450 mm, having the approved design and of the approved make as per manufacturers specifications Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing an ADA compliant Disability Service Desk having a lowered portion (800mm from FFL) and leg space of 450 mm, having the approved design and of the approved make as per manufacturers specifications Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing SS-304 studs having 35mm dia. of the approved brand and make inside the building on all floors in corridors, lobbies level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer, using the necessary adhesive including finishing work up to the satisfaction of the engineer in charge complete. Spec. No As director by engineer incharge.
Providing and fixing SS-304 strips of size 280mm x 35mm of the approved brand and make inside the building on all floors in corridors, lobbies level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer, using the necessary adhesive including finishing work up to the satisfaction of the engineer in charge complete. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing SS-304 strips of size 280mm x 35mm of the approved brand and make inside the building on all floors in corridors, lobbies level differences etc. as per accessibility standards and as per the installation instructions prescribed by the manufacturer, using the necessary adhesive including finishing work up to the satisfaction of the engineer in charge complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing Braille indicators for handrails of the approved design and make having Braille dots raised 0.5mm above base plate, to be installed at the specified locations as per the directions of the engineer in charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system. Spec. No As director by engineer incharge. (GROUND FLOOR)
Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system. Spec. No As director by engineer incharge. (FIRST FLOOR)
Fire exit and floor identification signage as per manufacturer's specifications, ADA compliant and modular system. Spec. No As director by engineer incharge. ( SECOND FLOOR )
Supplying and installing of in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3' x 4'.Product to be ADA compliant and modular system. Spec. No As director by engineer incharge. ( GROUND FLOOR )
Supplying and installing of in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3' x 4'.Product to be ADA compliant and modular system. Spec. No As director by engineer incharge. (FIRST FLOOR)
Supplying and installing of in position the signages " FIRE ORDER" it should contain the following matter on 3mm thick "Opaque" PVC foam board of computerized cut, PVC Non-reflective self adhesive vinyle painted foam board of 3' x 4'.Product to be ADA compliant and modular system. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand as per the direction of engineer in charge. Spec. No As director by engineer incharge. ( GROUND FLOOR )
Providing and fixing of high intensity reflective conspicuity tape 25 to 50mm width, on edges of treads in staircase including, cutting, pasting etc. of make 3M or equivalent brand as per the direction of engineer in charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing Ivory Colour european type wall-hung, of size 360mm x 360mm x 575mm with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge. ( GROUND FLOOR )
Providing and fixing Ivory Colour european type wall-hung, of size 360mm x 360mm x 575mm with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge. (FIRST FLOOR)
Providing and fixing Ivory Colour european type wall-hung, of size 360mm x 360mm x 575mm with flush valve of approved make including soil pipe, vent pipe upto outside face of wall, 100mm dia C.I. plug bend inlet pipe all fittings,cutting & making good walls, floors etc as directed by Engineer in charge. (SECOND FLOOR)
Providing and fixing Ivory Colour glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. ( GROUND FLOOR )
Providing and fixing Ivory Colour glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. (FIRST FLOOR)
Providing and fixing Ivory Colour glazed urinal of series with Pressmatic auto closing valve of having 32mm diameter P.V.C. flush pipe with fitting and flushing of approved make and arrangement including lead soil pipe, lead trap & soil pipe connection upto the outside face of wall etc.complete as directed by Engineer in charge. (SECOND FLOOR)
Providing and fixing of approved make Ivory Colour aquafree Waterless Urinal of with cartride size of 31.5x33x60cm including other necessary fittings etc. complete. ( GROUND FLOOR )
Providing and fixing of approved make Ivory Colour aquafree Waterless Urinal of with cartride size of 31.5x33x60cm including other necessary fittings etc. complete. ( FIRST FLOOR )
Providing and fixing of approved make Ivory Colour aquafree Waterless Urinal of with cartride size of 31.5x33x60cm including other necessary fittings etc. complete. (SECOND FLOOR)
Providing and fixing European type Ivory Colour glazed earthenware coupled closet Symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. Spec. No As director by engineer incharge. ( GROUND FLOOR )
Providing and fixing European type Ivory Colour glazed earthenware coupled closet Symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing European type Ivory Colour glazed earthenware coupled closet Symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing 1st class Ivory Colour glazed earthenware orissa type w. c. pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. Spec. No As director by engineer incharge(GROUND FLOOR)
Providing and fixing 1st class Ivory Colour glazed earthenware orissa type w. c. pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. Spec. No As director by engineer incharge (FIRST FLOOR)
Providing and fixing 1st class Ivory Colour glazed earthenware orissa type w. c. pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. Spec. No As director by engineer incharge (SECOND FLOOR)
Providing and fixing Ivory Colour glazed earthenware wash hand basin of 63 cm x 45 cm size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 (GROUND FLOOR)
Providing and fixing Ivory Colour glazed earthenware wash hand basin of 63 cm x 45 cm size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 (FIRST FLOOR)
Providing and fixing Ivory Colour glazed earthenware wash hand basin of 63 cm x 45 cm size including cold water pillar tap / cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall.. Spec. No. Bd.V.30 Page No.565 (SECOND FLOOR)
Providing and fixing Ivory Colour glazed earthenware lipped flat back / corner type urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec. No. Bd.V. 26 Page No. 564. (GROUND FLOOR)
Providing and fixing Ivory Colour glazed earthenware lipped flat back / corner type urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec. No. Bd.V. 26 Page No. 564. (FIRST FLOOR)
Providing and fixing Ivory Colour glazed earthenware lipped flat back / corner type urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. Spec. No. Bd.V. 26 Page No. 564. (SECOND FLOOR)
Providing and fixing Ivory Colour glazed earthenware sink 600 mm x 200 mm x 450 mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete. Spec. No. Bd.V.31 Page No.566 (GROUND FLOOR)
Providing and fixing Ivory Colour glazed earthenware sink 600 mm x 200 mm x 450 mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete. Spec. No. Bd.V.31 Page No.566 (FIRST FLOOR)
Providing and fixing Ivory Colour glazed earthenware sink 600 mm x 200 mm x 450 mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete. Spec. No. Bd.V.31 Page No.566 (SECOND FLOOR)
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc.complete as directed by Engineer incharge. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc.complete as directed by Engineer incharge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing sink cock with regular swinging spout (Wall Mounted Model) with wall flange with approved make incluidng other necessary fitting, etc.complete as directed by Engineer incharge. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets / union nut etc. complete as directed by Engineer in charge. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets / union nut etc. complete as directed by Engineer in charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing C.P. 2 Way BIB cock with wall flange of approved make including necessary sockets / union nut etc. complete as directed by Engineer in charge. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing C. P. BIB cock with wall flange of approved make including necessary sockets / union nut etc. complete as directed by Engineer in charge. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing C. P. BIB cock with wall flange of approved make including necessary sockets / union nut etc. complete as directed by Engineer in charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing C. P. BIB cock with wall flange of approved make including necessary sockets / union nut etc. complete as directed by Engineer in charge. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing Hand shower ( healthfaucet ) with 8 mm dia. 1 m long flexible tube having wall hook with approved make including necessary sockets / union nut etc. complete as directed by Engineer incharge. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing Hand shower ( healthfaucet ) with 8 mm dia. 1 m long flexible tube having wall hook with approved make including necessary sockets / union nut etc. complete as directed by Engineer incharge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing Hand shower ( healthfaucet ) with 8 mm dia. 1 m long flexible tube having wall hook with approved make including necessary sockets / union nut etc. complete as directed by Engineer incharge. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets / union nut etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing 450 mm x 550 mm size superior type belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing 450 mm x 550 mm size superior type belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing 450 mm x 550 mm size superior type belgium mirror with 16mm dia. nickel plated towel rod etc. complete. Spec. No As director by engineer incharge.(SECOND FLOOR)
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 cm and one no SS 304 hinged rail 76 cms & three no SS 304of (Grab Bar) 60 cms all including cutting and making good the walls and floors wherever required ,seat cover, cistern & wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating , bend, connecting piece of UPVC pipe up to the outside face of wall , making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating , bend, connecting piece of UPVC pipe up to the outside face of wall , making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Spec. No As director by engineer incharge.(FIRST FLOOR)
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating , bend, connecting piece of UPVC pipe up to the outside face of wall , making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use). Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572. (GROUND FLOOR)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572. (FIRST FLOOR)
Providing and fixing 15cm x 10cm salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap. Spec. No. Bd.V.38 Page No.572. (SECOND FLOOR)
Providing and laying 100 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.. Spec. No. Bd.V.39 Page No.573.
Providing and laying 150 mm dia salt glazed stoneware pipe including fittings such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.. Spec. No. Bd.V.39 Page No.573.
Providing and laying concrete pipes of I. S. NP. class of 300 mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. Spec. No. Bd.V.41 Page No.573.
Providing and constructing brick masonry inspection chamber 60 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140 kg with frame etc complete.. Spec. No. Bd.V.43 Page No.574.
Providing & constructing brick masonry inspection chamber 90 cm x 45 cm x 90 cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. lid 65 kg with frame fixed in cement concrete etc. complete with R.C.C. Cover medium duty 140 kg with frame etc complete.. Spec. No. Bd.V.43 Page No.574.
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing soak pit of size 120 cm x 120 cm x 120 cm including excavation and filling with brick bats. Spec. No. Bd.V.46 Page No.576.
Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 To 2.7 mm confirming To I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C. C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. ( The contractor shall give 3 yrs guarantee bond for payment ). Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 To 2.7 mm confirming To I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C. C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. ( The contractor shall give 3 yrs guarantee bond for payment ). Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing P.V.C. Rain water pipes of 160 mm outer diameter and having wall thickness of 2.2 To 2.7 mm confirming To I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C. C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. ( The contractor shall give 3 yrs guarantee bond for payment ). Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing on walls / ceiling / floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (GROUND FLOOR)
Providing and fixing on walls / ceiling / floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (FIRST FLOOR)
Providing and fixing on walls / ceiling / floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SECOND FLOOR)
Providing and fixing on walls / ceiling / floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (GROUND FLOOR)
Providing and fixing on walls / ceiling / floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (FIRST FLOOR)
Providing and fixing on walls / ceiling / floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SECOND FLOOR)
Providing and fixing on walls / ceiling / floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge(GROUND FLOOR)
Providing and fixing on walls / ceiling / floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (FIRST FLOOR)
Providing and fixing on walls / ceiling / floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge (SECOND FLOOR)
Providing and fixing on walls / ceiling / floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge.(GROUND FLOOR)
Providing and fixing on walls / ceiling / floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. (FIRST FLOOR)
Providing and fixing on walls / ceiling / floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. (SECOND FLOOR)
Providing and fixing on walls / ceiling / floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. (GROUND FLOOR)
Providing and fixing on walls / ceiling / floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. (FIRST FLOOR)
Providing and fixing on walls / ceiling / floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. (SECOND FLOOR)
Providing and fixing on walls / ceiling / floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge.(GROUND FLOOR)
Providing and fixing on walls / ceiling / floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. (FIRST FLOOR)
Providing and fixing on walls / ceiling / floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. Spec. No. BD.V 5 page 551 and as directed by Engineer in charge. (SECOND FLOOR)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No As director by engineer incharge. (GROUND FLOOR)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No As director by engineer incharge.(GROUND FLOOR)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No As director by engineer incharge. (FIRST FLOOR)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. Spec. No As director by engineer incharge. (SECOND FLOOR)
Providing and fixing H.D.P container Syntex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above1000 to 20,000 litres . Spec. No As director by engineer incharge.
RWH - Recharge Pit Providing and constructing recharge pit of 2.0m deep and 1.0m dia of pre-cast RCC rings with 6.5" dia x 25m deep borewell at the floor of recharge pit including installation of combination of solid/perforated PVC casing pipe wrapped around with netlon mesh including 300mm thick sidefilling around outside of RCC rings (annular space) with 40mm size boulders including filling of recharge pit up to 0.5m depth with 25-75mm clean washed gravels from bottom up followed by 0.5m depth of 10-25mm of clean washed stones followed by 0.5m of washed river fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) including netlon mesh between each gravel/fine aggregate (natural sand/crushed sand VSI grade finely washed etc.) media layer including covering with RCC slab, manhole frame & cover, PVC rungs, PVC end-caps, fittings etc. including arrangement for inlet & outlet pipe excavation & backfilling as shown in the drawing.The rate shall be inclusive of all labour, material, wastage, scaffolding, transportation, taxes, including all leads, lifts at all levels. All material should be of approved make. All works complete as per the drawing, technical specification and direction of the Engineer in charge.
Supplying, Drilling/Cleaning hole and injecting chemical. Application to be designed separately for Rebars as Simply Supported, Moment or Splice Connection as per EC2/TR 023 or relevant tested and accepted rebar guidelines. The chemical should have ETA approval for seismic rebar as a minimum qualifying criterion. Drilling hole with double flute type drill bits or hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A22 battery dispenser along with piston plug. The installation and the setting instructions should be strictly followed as per the manufacturer‘s recommendations. The adequate diameter and embedment of rebars to be decided as per PROFIS Rebar Software & the report to be submitted to the project manager/ design engineer for approval. Scanning before drilling to be done to avoid hitting existing rebars. Re 500 -12 mm dia 240mm depth
Providing and installing bio digester unit based on DRDO technology made of fibre reinforced plastic (FRP) having composition and following technical specifications and including necessary pipe and accessories up to 3 meter length, excluding the necessary excavation for installing the bio digester.Percentage of fibre glass (glass content in fibre glass should be minimum 30%): -33.33%Percentage of polyester resin: - 66.67%Water absorption (as per ASTM):-0.30%Flammability as per ASTMTensile strength:-115 MPASpecific Gravity at 25 degree centigrade 1.45Izod impact strength:-65KJ/M2Heat defection/distort temperature:-65deg CCorrosion resistance (Non Corrosive) fitted with Inlet pipe size rigid PVC: -100mmOutlet pipe size rigid PVC:-80mmGas outlet rigid PVC with Valve: 20mmBacteria immobilization PVC mattes (on all partition)With DRDO TOT g)Upto 100 user size (2.5mx2mx1m), Capacity ofBiodigester :-5000liters ,Area of top, bottom and side walls:-19.00sq.m, Area of partition walls: 8.00sq.m ,Tota lweigh to fFRP: 248.40Kilogram, Bacteria in oculums quantity:-1800liters ,Minimum thickness of side walls/top and bottom:6mm,Number of inside partitions: - 4, Minimum thickness of partition wall: 3mm
Providing and laying in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. work in foundations like raft, strip foundations, grillage and footings of R.C.C. columns and steel stanchions etc. including bailing out water, formwork, laying/pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for R.C.C. columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based PLC with SCADA enabled concrete Batch mix plant (Pan mixer) etc. complete. With natural sand/V.S.I. quality Artificial Sand
Providing and casting in situ c.c.M-20 of trap/granite/quartzite/gniess metal for R.C.C. beams and lintels as per detailed design and drawings or as directed including dewatering, formwork, compaction, fininshing the surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface or roughning if special finish is to be provided & curing etc. complete.
Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kg/Smt.
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50m. and spreading for embankment or stacking as directed.
Supplying hard murum/ kankar at the road site, including conveying and stacking complete.
Spreading hard murum for side width etc.complete
Compacting the hard murum side widths including laying in layers on each side with power roller including artificial watering etc. complete.
Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting with Intelligent Compactor with compaction analyzer and V-Sat attachment. to the required density. Grading I (Using Screening Type B (11.2 mm) Aggregate)
Providing and laying in-situ M30 Grade unreinforced plain cement concrete pavement over a prepared sub base with 43 grade cement , coarse and fine aggregate( natural sand/ VSI grade finely washed crushed sand) conforming to IS 383, using fine and coarse aggregates combined gradation as per Table 600-3 of MORTH Specification 2013, mixed in a batching and mixing plant/ non tilting mixer and Weigh batcher as per approved mix design, admixtures, transporting to site, spreading, laying with approved make paver,compacted and finished in a continuous operation, finishing to lines and grades as directed by Engineer-in-charge and curing by curing compound /by providing cement vata in cement Mortar 1:8 @0.6m X 0.6m centre to centre, admeasuring 80 mm at bottom and 40 mm at top with depth of 75mm and maintaining the same throughout curing period by any other method approved by Engineer-in-charge.
Excavation for catch / side water gutter in all sorts of soils to the specified section including stacking the excavated stuff in a regular bund and disposing of unsuitable or excess stuff as directed all sorts of soils.
Providing and casting in situ cement concrete in M20 of trap/ granite/quartzite/gneiss metal for bed blocks, foundation blocks and such other items including bailing out water, plywood/steel formwork, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based PLC with SCADA enabled reversible Drum Type mixer . . With natural sand. Spec. No. : Bd.E.4 Page No. 289 and B-7, Page No.38
Providing cast in situ / ready mix M20 grade cement concrete for head walls of CD work / retaining walls etc. including necessary form work, compaction, finishing and curing etc. complete. (with concrete batch mix plant (pan mixer) with SCADA
Providing and laying in situ / ready mix M-20 controlled cement concrete of trap/ granite/ quartzite/ gneiss metal for RCC work in solid/ deck slab etc. including ramming, vibrating, curing, formwork, centering and finishing in cement plaster excluding reinforcement etc. complete. (with fully automatic micro processor based PLC with SCADA enabled concrete batch mix plant / pan mixer and fine agreegates of required specifications (Natural sand / VSI sand finely washed etc ) i) Height up to 5 m, normal rate. ii) Height 5 to 7.50 m, add 5 percent extra over basic rate. iii) Height 7.50 to 10 m, 7.50 percent extra. iv) Over 10 m Height, add 10 percent extra for every 2.50m rise.
Providing and fixing 3.5 to 4 mm thick Veneer finish wall Panaling made out of 50 x 25 mm (finished size) C.C.T.W. frame work or size of 600 x 600 mm center or as per site condition covered by 6 mm thick marine plywood of the requisite manufacture viz Anchore / Century / Kenwood /Duro / jet or equivalent generally confiriming to I:S 710- 1980 finished with 3.5 to 4 mm thick matching Veneer of approved color and in satin wallnut groov matched veneer pattern and design including melamine polishing & design with antitermite treatment etc. to plywood and woodwork with ten years guarantee bond etc. including all lead and lifts complete as per Architects Drawing and instructions of Engineer Incharge.
Providing & fixing in position Stage flooring Made from 18mm plywood 1200x2400 &18mm Teak wood planks 100x800 having tongue & groveonSal-wood frame of 50x100at 600mm ctocon stage surface including cos to frequired Cut-Outs, decorative mouldings / finishing-items /polish etc., as per Architectural & Acoustical Design & Instructions & Complete in al aspects. including all materials labour, finishing etc complete
Providing Teak wood planks above 2.5m length
Sofa Set 3+1+1 Providing & fixing Sofa Set 3+1+1 Brown and Cream leather DIMENSION Length:182.5(cms) Breadth(cms): 100 (cms)Height (cms): 100 (cms) Weight (Kilograms): 66 (Kilogram) Seating Capacity: Five Seat
Providing & Arrangemnt of High Back, Sync hronized Mechanism with Multiple Locking, Adjustable Armrest, Gaslift for Seat height adjustment, Standard 5-prong P/Nylon Base with Leatherite Upholstery
Providing & Arrangemnt of Mid Back, Normal Syncro Mechanism, Fixed Armrest, Gas lift for Seat height adjustment, Standard 5-prong/Nylon Base with Leather Upholstery
Providing & Arrangemnt of Mid Back, ECO CTS Mechanism, Fixed Armrest, Gas lift for Seat height adjustment, Standard 5-prong/Nylon Base with Fabric Upholstery
Supplying and fixing of Acrylic baord 4mm thk mounted in Steel frame size 45cmx30 cm as per requirement with required lettering.
Medium Height Partition @ 1800/1200HT TILE BASED PARTITION SYSTEM:- Tile based Aluminum partition system of 1800/1200 mm ht. made of 60mm thk aluminum frames having two separate race ways for laying electrical & computer wiring. The wire management shall be through to the race way to be fitted at bottom of partition and other immediately below of work top with hook on type raceway cover for easy access of wires. Frames to be joined by aluminum connectors with M6 x 16 pan-head machin screw and washer with aluminum post cover. Post cover of snap on fashion to be connected on aluminum connectors. All visible aluminium to be in anodized finish. The top/ exposed sides of the frame and posts should be covered with horizontal/ Vertical trim and caps made of Aluminum in anodized finish in order to enhance its look.Upper tiles of partition to be in Soft Board or Marker tile of 9mm. thk., and prelaminated partical board lower tiles in laminate finish of 9mm. thk. on both the sides.
Free Standing Table @ 1500Lx600Dx750HT Providing and fixing Table of Size 1500 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
Free Standing Table @ 1350Lx600Dx750HT Providing and fixing Table of Size 1350 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
Free Standing Table @ 1200Lx600Dx750HT Providing and fixing Table of Size 1200 x 600 x 750 mm. Top: made from 25 mm Prelaminated Particle board. All edges are covered by 2 mm. Thk. PVC edge bands glued by hot melt glue applied by auto edge banding machine. Legs : C Shape made from CRCA Sheet with Powder Coat finish. Modesty panel : Made from 18mm both side prelaminated particle boards.All edges are covered by 0.8mm PVC edge bands glued by hot melt glue applied by auto edge banding machine.KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT Providing & Fixing Curviliner Workstation @ 1500/1500Lx600/600Dx750HT, Curvilinear Table Top @ 1500/1500Lx600/600D :- TOP to be made of 25 mm thick Prelaminated particle board with PVC edge band, GABLE END to be made of 25 mm thick Prelaminated particle board with PVC edge band, KEYBOARD TRAY ( WITHOUT MOUSE TRAY ) :- Metal Powder Coated - Black Color, CPU TROLLEY :- Metal Powder Coated - Black Color, along with 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board,
Conference Table @ 3600Lx1400Dx750HT Providing & Fixing of Main Table @ 3600Lx1400Dx750HT - made up of 18+18mm Thick MDF top with PVC Membrane finish and waterfall edge profile. Aluminium Anodizied finish beeding of 4mm thich is running all over the table top edge. Gable ends is Aerofoiled Shape with front edges in PVC Membrane finish and rest in Prelaminated MDF with batton structure. Gable ends should be hollow from inside for the provision of passing electrical and Data wiring. , MODESTY PANEL:- to be made of 18 mm thick Prelaminated particle board with PVC edge band Access Flap:- For Wire manager 2 Nos.
3 DRAWER PEDESTAL UNIT @ 392L x 450D x 680Ht. mm. 3 DRAWER PEDESTAL UNIT having overall size 392L x 450D x 680Ht. mm. with central lock and key. 3 Drawers and body are complete metal with powder coat finish, facia in 18 mm prelaminated particle board.
Medium Height Steel Storage @ 750Lx450Dx1200HT Providing and fixing Openable Steel Storage of 750 x 450 x 1200Ht, with 2 adjustable shelves, Complete body & shutter made in 0.8 mm thick & Top in 2 mm thick CRCA, 2 Shutter to be mounted with the help of cup hinges, and 4 adjustable levelers, enitre storage in powder coated finish with 60 to 80 microns. with 25 mm. thk. as per drawing.
Public Seating Chair. - 3 Seater Providing and Fixing 3 seater Public seating chair made of complete metal with Legs in Crome finish and seates in silver powder coating finish.
Preparing Lawn:- Excavating the ground to a required depth of 30 cms., removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manuar in excavated area in 3:1 proportion to a height of 30 cms. Mixing garden soil and manure throughly, well levelling, watering on previous night, planting required variety of lawn grass as directed and maintaining till well established by watering, wedding, clipping, rolling etc. complete.
Planting large flowering/Shady trees : Digging pit with size 0.9mx0.9mx0.9m, removing and conveying unwanted stuff to a required distance as directed. Filling the pit with approved excavated material upto a height of 0.30 m. and remaining height f 0.60 m. with fresh garden soil and manure thoroughly (well levelling as directed, watering previous night, Planting one or two year old healthy trees sapling as per specifications.Maintaining till well established by watering, weeding, stirring of soil replacing of casualty's etc, complete.
Planting small and medium size ornamental/Flowering Plant : Digging pit with size 0.6mx0.6mx0.6m, removing and conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil & Farm yard Manure upto a height of 0.60m in 3:1 proportion. Mixing soil and Manure thoroughly well, levelling watering on previous night Planting one or two year old healthy plant saplings as per specification. Maintaining till well established by watering, strring, of soil and manure, replacing casualties, etc, complete.
Preparing flower Bed:- Excavating the ground to the required depth of 30 cms., removing & conveying unwanted stuff to a required distance as directed. Filling fresh garden soil & manuar in excavated area in 3:1 proportion to a height of 30 cms. for Mixing garden soil and manure throughly, well levelling, watering on previous night, planting seedlings of required anuals 25 cms a part. maintaining till well established by watering, wedding, clipping, rolling etc. complete.
Mogra Plant/Creepers/Climbers : Excavating pit with size 0.3x0.3x0.3 m. removing and conveying unwanted stuff to a required distance as directed.Filing the pit with approved excavated material upto height of 0.15 Mtr.anx remaning heigh of 0.15 mtr. with fresh garden soil and manure in 3:1 proportion. Mixing soil and manure thoroughly well levelling wtering on previous night Planting one or two year old healthy plnt as per specifications. Maintaining till well established by watering, weeding prunning, stiring, replacing casualties etc, complete.
Rose Plant : Excavating pit with size 0.3x0.3x0.3 m. removing and conveying unwanted stuff to a required distance as directed. Filling the pit with fresh garden soil and manure thoroughly well, levelling watering on previous night Planting 40 to 50cms. height healthy plant of required rose variety. Maintaining till well established by watering, weeding string prunning, replacing the casualties etc, complete.
Preparing Edging or Border:- Excavating the ground to the required depth of 20 cms.,in the removing & conveying unwanted stuff to the required distance as directed. Filling the excavated part with fresh soil & manuar in excavated area in 3:1 proportion to a height of 20 cms. Mixing , levelling, watering the same planting unrooted cuttings at distance of 15 cms a part watering and maintaining till well grown the stage of prunning.
Providing and laying Glazed Vitrified tiles Matt/Antiskid/polished finish of size 600X1200 in floor in (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Providing and laying glaze Vitrified tiles MATT/GLOSS finish having decorative type of size 1200 millimeter x 1800 millimeter of 9 to 10 millimeter thickness with bonding chemical and confirming to IS15622-2017 ( Group Bla ) of approved make shade and pattern for flooring in required position laid on a bed of bonding chemical filling joints curing and cleaning etc .complete , Crazing resistance 4 cycle @ 7.5 bar minimum class -1 ( format ) minimum class -2 ( polish ) approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. as directed engineer incharge and approved by architect incharge
Providing and fixing 12mm thk toughened etched (glassetching 40% to glass) as per the design, as per the design. Glass to be fixed at top & bottom in heavy guage aluminium 'c' channel concealedin floor & boxing.with patchfitting as neccessary after shop drawing , Cost to be inclusive of silicon sealantto the periphery of the glass as directed engineer incharge and approved by architect incharge
Providing and fixing in position structural glazing faces of building made out of colour anodized aluminium frame curtain wall of 63 mm x 57 mm x 2.20 mm thick including toughened reflective glass 5 mm thick of 900 x1200 mm size. The item shall include toughened coloured reflective glass 5 mm thick water proofing silicon sealant, G.E. winsil 10/20, G.E.ultra glaze including alumnium fixtures.S3 screws and nut bolts, scaffolding , m.s.angle cleats and frame work of 65 mm x 65 mm x 6 mm and scaffolding etc. complete. Minimum 20% area of structural glazing shall be openable for openable panels. aluminum hinges, wind stays and locking arrangements and aluminum angle or tee section of required size , preparation of shop drawing and getting it as directed engineer incharge and approved by architect incharge
Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.including all leads, lifts, etc. comlete
Providing & fixing of Stainless steel 304 grade & chrome silver mortise Handle D type. lever Handle with moritse pull hanlde lock. Finish Nickel Stainless Steel. Make for range of thickness of door 32 mm to 55 mm thk. With fitting, Screws etc. & holes in granite etc as needed. the product should be racognised international brand like Ozone etc. as directed engineer incharge and approved by architect incharge
Providing and fixing complete.4mm thk CNC cutting in ALUCOPANEL SHEET of uniform thk & APPROVED COLOUR . the cnc perforated design complete ,the portion of the work to be installed on site at right place with perfect line and level. The installation of the same should be such that screws used shouldn’t be visible . the ms cnc perfoarated plate to be approved by the architect with respect to the design before installation with ISI Mark is code IS8147(1976) FOR THE FOAM) or Approved By Architect [ Rates are inclusive of all transportation of material, lead, lift, labour charges, including 3years maintainance & material should be approved by as directed engineer incharge and approved by architect incharge before use. ] size of 1000mm x1000mm
Providing and fixing With Installation complete, with green artificial lawn Color -Multi colour Material Polypeprene Thickness Of Green Wall 10mm-15mm Brand -Taiwan Customised Height and Width Gauge 3/8" size 600x600X10MM with ISI Mark or Approved By Architect [ Rates are inclusive of all transportation of material, lead, lift, labour charges, including 3years maintainance & material should be approved by Executive Engineer before use. ] green artificial lawn Color -Multi colour Material Polypeprene Thickness Of Green Wall 10mm-15mm Brand -Taiwan Customised eight and Width Gauge 3/8" size 0.60x0.60as directed engineer incharge and approved by architect incharge
OIL ACRYLIC ONB CANVAS PAINTINGS WITH FRAMING AND FIXING ETC WITH ETHNIC CONTENT OF GOOD ARTIST AND APPROVED DESIGN BY THE ARCHITECT Material: Canvas Frame Type: Framed Dimensions: Length : 35.5, Width : 1, Height : 23.8 Inches Weight: 2 Kgs Colour: Multicolour Orientation: Landscapeas directed engineer incharge and approved by architect incharge
MDF iengraving and design work with cnc machine using mdf of 12 mm thicknessuse for the back pannel and panneling of desing work as sugest as directed engineer incharge and approved by architect incharge
Providing and fixing of wall paper of best quality & approved design & concept as directed engineer incharge and approved by architect incharge
Providing and fixing complete.4mm thk CNC cutting in mild steel plate of uniform thk. the cnc perforated design complete ,the portion of the work to be installed on site at right place with perfect line and level. The installation of the same should be such that screws used shouldn’t be visible . the ms cnc perfoarated plate to be approved by the architect with respect to the design [ Rates are inclusive of all transportation of material, lead, lift, labour charges, including 3years maintainance & material should be as directed engineer incharge and approved by architect incharge before use. ] before installation . size of 1000mm x1000mm
Providing and fixing With Installation complete green wall for indoor application ( Greenwall with green leaves & various colour flowers ) dense mix shrub,big leaves tile various colours of bongainvillea all in Multi colour Material Polypeprene Thickness Of Green Wall 10mm - 12mm -15mm ( three varieties ) Brand -Taiwan Customised Height and Width Gauge 3/8" size 300x300X10MM with ISI Mark or Approved By Architect [ Rates are inclusive of all transportation of material, lead, lift, labour charges, including 3years maintainance & material should be approved by Executive Engineer before use. ] green artificial lawn Color -Multi colour Material Polypeprene Thickness Of Green Wall 10mm-15mm Brand -Taiwan Customised eight and Width Gauge 3/8" size 0.30x0.30 as directed engineer incharge and approved by architect incharge 10 mm
Providing and fixing With Installation complete green wall for indoor application ( Greenwall with green leaves & various colour flowers ) dense mix shrub,big leaves tile various colours of bongainvillea all in Multi colour Material Polypeprene Thickness Of Green Wall 10mm - 12mm -15mm ( three varieties ) Brand -Taiwan Customised Height and Width Gauge 3/8" size 300x300X10MM with ISI Mark or Approved By Architect [ Rates are inclusive of all transportation of material, lead, lift, labour charges, including 3years maintainance & material should be approved by Executive Engineer before use. ] green artificial lawn Color -Multi colour Material Polypeprene Thickness Of Green Wall 10mm-15mm Brand -Taiwan Customised eight and Width Gauge 3/8" size 0.30x0.30 as directed engineer incharge and approved by architect incharge 12mm
Providing and fixing With Installation complete green wall for indoor application ( Greenwall with green leaves & various colour flowers ) dense mix shrub,big leaves tile various colours of bongainvillea all in Multi colour Material Polypeprene Thickness Of Green Wall 10mm - 12mm -15mm ( three varieties ) Brand -Taiwan Customised Height and Width Gauge 3/8" size 300x300X10MM with ISI Mark or Approved By Architect [ Rates are inclusive of all transportation of material, lead, lift, labour charges, including 3years maintainance & material should be approved by Executive Engineer before use. ] green artificial lawn Color -Multi colour Material Polypeprene Thickness Of Green Wall 10mm- 15mm
PASS/HATCH BOX SITC OF Pass Box having size 610mm x 610mm in accordance to the site requirement made of SS Grade 304, having door interlocking, UV lights electronic controls, flush to operating theatres inside wall panels / Supply, Installation Testing and Commissioing Hatch Box Indigenous For Operation theater Indian Supply & Installation of STATIC PASS BOX having following technical specifications:-Body shall be made out of Stainless Steel sheet (304 Grade). The unit is provided with heavy duty electromagnetic interlocking arrangement. Electric buzzer, UV Light (8 Watt) – 1 No & lighting arrangement shall be provided. Provided with SS doors with viewing glass.It should be CE compliance.as directed engineer incharge and approved by architect incharge
CURTAINS : consisting of :- HOSPITAL CURTAIN TRACK : Made up of Aluminium Extruded of grade 6063 hollow section of rectangular shape size 34mm x16mm of 16G with powder coating finish, as per choice : Supporting systems of curtain track shall consist of following; Wall bracket made up of plastic molded caps ROOF SUSPENSION : Made up of aluminium pipe . HOOKS : Comprises of wheel type runners for easy & smooth sliding of the curtain. CURTAIN CLOTH : Chemically treated Stain retardant fabric with Top Mesh/net of nylon. Top mesh size carioes from 18"to 24" / Supply, InstallationTesting and Commissioing of Cubicle Curtain Track :Ceiling Cubical Partition Track Aluminum rail with plastic runner, rings and netted curtains It is made from heavy Duty Aluminium cubicle track size 20mm wide x 30mm high, made of aluminium natural anodized to 15 microns complete with continuous PVC liner, nylon gliders and hooks, plastic end cap, connecting bridge, overlapping joint connector, wall brackets with matching screws to make up cubicle height to 2100mm clearance from floor level at 1000mm spacing and securely fixed to above slab. as directed engineer incharge and approved by architect incharge
BED HEADPANEL - ALUMINIUM extrusion 6063 GRADE powder coating finish length: 1000mm / 1250mm. Provision for 03 gas outlets as per sample provided by Hospital electrical switch socket 04 nos Provision for Nurse call system and communication CAT 6 port. The panel with accesoories like monitor tray, cable basket, medicine basket- 01 each along with 01 rail / Horizontal/Vertical 2100mm Bed Head Panels: It should CE ompliance. It should be constructed of extruded aluminum profiles with 2 hannels to provide a modular surface mounted unit with integrated accessory rails for equipment management. 2 separate partition rows wise for medical gas es and electrical soekcts. All med gas piping shall be hard-piped and brazed to a single point of connection. Fascia panels, top, middle and bottom cover panels shall be removable for access for easy installation and maintenance. It should be pre piped with 4 gas outlets. It should have 6 electrical sockets., RJ-45=1, RJ-11=1, Gas Outlets with HTM02-01 standards complies BS gas outlets points with NIST connection Terrminal units shall have gas indexing geometry. Other gas specific indexing geometries are not acceptable. Terminal unit front fascia should be metal and it should be hundred percent metal. Gas specific components comprising the terminal unit second fix shall be manufactured from die-cast zinc alloy or similar hard wearing metal. Plastic components are not acceptable. Terminal units socket castings shall be permanently coated with a low friction fluoropolymer for maximum reliability and service life. The terminal unit socket die-casting shall incorporate a gas indexing pin to overcome the risk of loosening due to rough handling or abuse. The second fix socket shall incorporate a sheer-plane to safeguard the first fix and pipeline in the event of accidental damage or bed jacking. Gas specific components shall incorporate the gas identity marking permanently stamped or cast into the component surface. The first fix shall be all metal construction, with a brass base block and copper stub pipe. The first fix shall incorporate an integral check valve to enable servicing of the second fix and valve seals without isolation of the gas supply. Probe roller pins shall be manufactured from stainless steel. Wall mounted terminal units shall be provided with white ABS mounting box with matching fascia. The mounting box shall have smooth rounded corners to avoid the possibility of injury. A bezel shall be available to cover the plaster edge, provide a neat and easily to clean finish. as directed engineer incharge and approved by architect incharge
Supply, Installation Twin Plate X Ray Viewer -X-Ray View Panel - 1no. for each OT (inside OT work only) :The system should electrical safety codes for high & low voltage system. The theatre is to be equipped with a 2-plate X-Ray viewing screen. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with the theatre wall for hygienic and ease of cleaning purpose. The X-Ray viewing screen should be designed for the purpose of front access. The X-Ray viewing screen should be illuminated by 4 pieces of high frequency fluorescent lamps and the dimming is controlled by the usage of dimming ballast with the PCB that is mounted inside the box. Size of the unit should be not less than 800 x 400 mm. It should have CE compliance under Class 1 Medical devices directive. / Supply, Installation Twin Plate X Ray Viewer -X-Ray View Panel - 1no. for each OT (inside OT work only) :The system should electrical safety codes for high & low voltage system. The theatre is to be equipped with a 2-plate X-Ray viewing screen. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with the theatre wall for hygienic and ease of cleaning purpose. The X-Ray viewing screen should be designed for the purpose of front access. The X-Ray viewing screen should be illuminated by 4 pieces of high frequency fluorescent lamps and the dimming is controlled by the usage of dimming ballast with the PCB that is mounted inside the box. Size of the unit should be not less than 800 x 400 mm. It should have CE compliance under Class 1 Medical devices directive.
Supply, Installation Testing and Commissioing 2- Bay Surgical Scrub Station-Stainless Steel Scrub Sink Indigenous : Scrub stations for each operation theatre should have been designed to ensure that surgeons and staff can undergo a thorough aseptic scrub, whether using the count stroke or timed scrub methods. Stainless Steel Scrub Sink. Each fixture is fabricated from heavy gauge, type 304, stainless steel and is seamless welded construction polished to a satin finish. Hands free operation includes infrared sensor with a built-in range of adjustment. User definable settings of 3, 6, 12, 30 and 45 seconds, 1, 3, 5 and 10 minute are available. A thermostatically controlled mixing valve automatically maintains water. It should have a foot operated facility. It should have CE compliance under Class 1 Medical devices directive. / Supply, Installation Testing and Commissioing Storage Unit Indigenous-Storage Unit should be made out of 0.80 - 1.60 mm thick AISI-304 Stainless steel. The storage unit should be divided 2 or more parts and each part should have individual glass doors with high quality locking system. These doors should be installed on the storage units with the help of imported fittings allowing an opening allowance of 90-100 degree. Each part should be provided with Stainless steel-304 racks which should be completely detachable type. The storage unit should be fitted with 5mm thick glass door and mounted flush with the theatre wall. The storage unit should be continuously ventilated by positive air in the OT through ventilation holes provided at the bottom and top of opposite sides. The dimensions of each storage unit should not be less than height 1800 - 2100mm x width 900 – 1200 mm x depth 300 - 350mm. The storage units should be designed in a way that they are flush with the OT wall panels and the units should be air tight, not allowing any leakage between units and the wall panels.It should be CE compliance.
Supply, InstallationTesting and Commissioing of Cubicle Curtain Track :Ceiling Cubical Partition Track Aluminum rail with plastic runner, rings and netted curtains It is made from heavy Duty Aluminium cubicle track size 20mm wide x 30mm high, made of aluminium natural anodized to 15 microns complete with continuous PVC liner, nylon gliders and hooks, plastic end cap, connecting bridge, overlapping joint connector, wall brackets with matching screws to make up cubicle height to 2100mm clearance from floor level at 1000mm spacing and securely fixed to above slab.as directed engineer incharge and approved by architect incharge
Supply, InstallationTesting and Commissioing of Intravenous Track I.V Track: It should be made from heavy Duty Aluminum Intravenous track 'U' configuration size : 35mm (W) x 19.2mm(H) make of aluminum natural anodized to 15 microns complete with wall brackets with matching screws all strictly in accordance with the manufacturer's instruction 1 no. IV carrier to a set of IV support track complete with 5 points Telescopic Bottle Holder adjustable 600mm~900mm tree. as directed engineer incharge and approved by architect incharge
Supply, InstallationTesting and Commissioing Grab Rail Crash Guard System The system fixed to brick wall at 900mm center high from finished floor level comprising continuous aluminum rail retainer, adjustable rail mounting base, with impact absorbing strip, end cap and high impact vinyl acrylic snap-on textured surface cover. “140mm Height x 80mm thickness”. Able to withstand abrasion, Weather resistance and fire retardant, Textured to provide and anti –slip surface. Fitting and anchorages that can withstand corrosion exposed to normal envirmental conditions. Tested to UL-94 ( Underwriter’s Laboratory)with a V-O rating for fire retardance. Designed to comply with static load, impact and deflection requirements in accordance with applicable application in ASTM-E894 and ASTM-E935 as directed engineer incharge and approved by architect incharge
Supply, InstallationTesting and Commissioing Corner Guard Protection System The system fixed to brick wall at the corner from finished floor level. Adjustable end cap. High impact vinyl acrylic snap-on matt finished. “50mm wide x 10mm thickness x 900mm length “. Corner guard system consist of following: PVC cover, base, top and bottom end cap in different color etc. Able to withstand high impact and abrasion, Weather resistance and fire retardant, Anti –slip surface Textured for an anti-scratch surface. Fittings and anchorages that can withstand corrosion exposed to normal envirmental conditions. Easy to install and maintain. Tested to UL-94 ( Underwriter’s Laboratory)with a V-O rating for fire retardance as directed engineer incharge and approved by architect incharge
HPL Double Leaf Manual Swing Door: Supply, Installation, Testing and Commissioning of HPL Double Leaf Manual Swing Door Inside Open able Flush Door of size 1800 X 2100mm having viewing window on the shutter of sizes 300 X 300mm. The Door frame is made of Extruded Aluminium Profile having Gasket to provide Leak less mechanism on three sides; the Door will have drop seal to provide sealing against the floor. Door will have Dorma TS-68 Door Closer, D type Handle and Cylindrical Door lock system. as directed engineer incharge and approved by architect incharge
" PVCu polymer not less than 2.5mm thick that can handle temperatures up to 140°F /60°C. thermoformble HACCP approved food safe polymer should achieve ASTM E84-08 Class A for fire resistance, and ASTM D5420, exceeding 160 inch lbs for Impact resistance, It should conform to USP 797/800 hygienic standards, with low particle emission complying to ISO Class 2 cleanrooms, fungi and mold resistant, excellent performance to be mounted on calcium silicate sheets backed up with proper aluminium grid framework and necessary studs having thickness of 2.5mm backed by calcium silicate 12mm thickness supported by necessary framework with metal stud"/ Supply, Installation, Testing and Commissioning of Indigenous Wall panels for inside OT It should have CE compliance under Class 1 Medical devices directive. The 80mmthk wall panels will be constructed using 0.8mm SS304 Steel sandwich panel with core consisting of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40 kg/m3. The individual wall panels shall use the tongue and groove technology for joining two panels, no welding should be allowed. The gaps between panels shall be suitably filled with metal filler/epoxy and sanded flush. Stainless Steel plate finished to fine grain surface, treated properly to take antifungal paint. Anti bacterial paint should be coated on the wall panels. as directed engineer incharge and approved by architect incharge
"Anti- Static Conductive Vinyl Flooring: Supply, Installation and Commissioning of Vinyl Anti Static Conductive Flooring in Roll form seamless with perfectly curved flash-covings, resistance to mechanical stresses and dynamic loads and having ESD/ EMI (conductive) protection characteristics, 2 mm thick, washable. The floor will be laid flat along with self-levelling compound within a tolerance of ±3mm over any 30 Sq.mtr areas. Copper grounding strip minimum of 0.05 thick and 50 mm width will be laid flat on the floor in the conductive adhesive and connect to copper wire of grounding attaching it to main earthing strip/ground. The flooring will be antifungal/anti microbial, scratch, fire, chemical, slip resistant, non corrosive and smooth. The floor finished level will pass over a concealed cove former and continue up all the walls on all four sides by 100mm"/Supply, Installation Testing and Commissioing Condutive Flooring : Flooring In OT area: Providing & fixing 2mm thick Conductive flooring with carbon backing total thickness 2.00mm, total weight 3.000 g/m2 polyurethane reinforced ,scratch resistant, fire resistant, chemical resistant , slip resistant, anti fungi & bacterial growth , dimensional stability 0.40%, static electrical charger < 2Kv , impact sound reduction approx +4bd, electrical resistant. Installation : The flooring would be installed on a smooth, clean sub floor which should be free from any undulation .A copper strip/mesh should be layer under the tiles, with one earthing point for every 150 sft of area and good quality water based adhesive for fixing as per as manufacturers recommendation. Thermal Welding : The joints must be welds by the heat fusion process to get a seamless floor. The joints in the flooring should be sealed by using a PVC welding bar of matching colour to be supplied by the manufacturer, using a hot air gun for fusion of welding bar with flooring. with self levaling coumpound .Supply, Installation, Testing and Commissioning of Self leveling compound of 3mm in OT areaThe hyper-fluid self-leveling product with prolonged work ability, extra rapid hardening, compensated shrinkage, suitable for high-resistant adjustment from 2 to 4mm of irregular non-planer substrates before laying homogenous tiles with very low TVOC emission and hypo-allergenic cements. as directed engineer incharge and approved by architect incharge
Calcium Silicate Ceiling Panels: Calcium Silicate Ceiling Panels having 8mm thickness supported by necessary framework with metal stud, the Ceiling Panel with Anti Bacterial Paint. /Supply, Installation, Testing and Commissioning of Indigenous Ceiling panels for inside OT. It should have CE compliance under Class 1 Medical devices directive. The 50mmthk ceiling panels will be constructed using 0.8mm SS304 Steel sandwich panel with core consisting of rigid polyurethane foam, which has been injected under high pressure, with a minimum density of 40 kg/m3. The individual ceiling panels shall use the tongue and groove technology for joining two panels, no welding should be allowed. The gaps between panels shall be suitably filled with metal filler/epoxy and sanded flush. Stainless Steel plate finished to fine grain surface, treated properly to take antifungal paint. Anti bacterial paint should be coated on the ceiling. as directed engineer incharge and approved by architect incharge
Laminar Air Flow System: Supply, Installation, Testing and Commissioning of Laminar Air Flow System of size ---mm. The laminar should be constructed with Aluminium sheet Laminar system will introduce the highest air quality into the operation theatre. Air should be diffused into the room uniformly over the total area through perforated stainless sheet SS 304 grade. The air diffusers should be installed in a manner which allows them to be removed for easy maintenance of air filter. HEPA filters of H14 Grade 99.97% efficiency complying to EN1822 Standards are used to ensure high quality clean air is supplied and under tight control of bacteria infection system. / Supply, Installation Testing and Commissioing of Indian Unidirectional Laminar Air Flow Plenum Ceiling Indigenous. Size 2400mm x 2400mm with Mini Pleat Hepa Filter-Unidirectional Low Turbulence Laminar Air Flow Plenum Ceiling ,Planair Ceiling System, standard size. PLENUM UNIT - The complete unit shall have factory prepared fine sealing system. It should be perfectly seamless integration of ceiling mounted equipment and OT Ceiling. It should be flexible modular range of solutions, adjustable to the local requirements .It should be made out of high quality and durable materials, filter housings and pressure chamber are made out of Aluminum. It should have a low pressure drop allows for the long-term usage of the HEPA miniplete H13/H14 filters . It should have reliable filter efficiency our filters are guaranteed to remove particles and gems with the usual H 13/H14 filters retaining 99.99 % of the particles and germs. It should have minimal pressure drop a low pressure drop ensures the energy saving characteristic of the Laminar Flow Ceiling . Air & light diffuser made out of two layer of mono filament precision woven polyester for the plan air ceiling to give a “LAMINAR FLOW” of filtered air. It also provides a diffused shadow less lighting system with a control on the intensity of luminance by using high frequency electronic fluorescent tubes and ballasts.It should be CE compliance. as directed engineer incharge and approved by architect incharge
Return Air Risers: SITC of Return Air Riser will be in GSS Pre-coated sheet with GI hardware and perforated Grills. Risers will be sealed with silicone sealant, and Elastomeric Foam Gaskets etc. It will have provision of 10 Micron Pre- Filter with filter holding clamps. Suction Perforated Grille SS 304/Aluminium. as directed engineer incharge and approved by architect incharge
"Bio Air - Conditioning for Laminar flow including external Condensing unit (ODU) of appropriate CFM and TR based on Heat Load calulations Should maintan approprate Humidity & Temp. Control, and also maintain the positive pressure. The panels 43mm thickness with PUF Insulation density 40kg/cum+-2, shoud be both sides precoated GI(24g) mounted on Aluminium frame. It should comprise of various sections such as Pre-Filter Section with Flange type washable Pre filter of 10 micron EU4 grade with galvanised steel sheet (GSS) frame with section, Fine Filter section Flange type washable Pre filter of 5 micron H14 grade with galvanised steel sheet (GSS) frame with section, DX type Cooling Coil Section With 8/10 row deep DX coil, Drain pan in SS 304 construction with Nitrile Rubber Insualtion, Electric Heater section with heaters for suitable Kw in 3 banks of equal capacity. (where applicable) Blower section with DIDW type backward curved blower with suitable static pressure. Motor and Blower are mounted on common base frame. Canvass connections at the outlet of the fan Limit switch & Marine light in fan section. Supply air section with Extruded Aluminium low leakage type manual Supply air damper. The Blower and Motor section should be of reputed make There will be access door across every section of AHU. Installation of unit including up to 10 RMT. Copper piping, MS stand, expansion valve, insulation, cabling etc. Pre filters having dust spot efficiency of 05 to 10 microns AHU ( Conforming to IEC 60204-1 STANDARDS ) / Supply, Installation Testing and Commissioing Inside OT Ducting ,AHU 6000 CFM of 125 static ,Condendsing Unit 11 TR -20”/22” Aluminum Ducting for HVAC with nitrate insulation inside each OT : Aluminium ducting with acoustic & Thermal installation (along with provisions for fresh air) and fabrication with specifications 24/22 gauge. Supply, installation and testing of multi-blade type louver dampers of aluminium for ducts coolers to be provided with suitable links, levers and quadrants for manual control of volume of air flow and for proper balancing of the air distribution system. 6000cfm AHU with condensing unit for each OT : Floor mounted One Double Skin Air handling Unit construction with PUF Sandwich Panels at a static pressure of 120 mm WG complete with backward curved blower, TEFC blower motor suitable for operation on 415 V +/- 10%, 3Phase, 50 Hz, A.C. Supply complete with 8 Rows copper tube, aluminium finned DX cooling coil, pre-filter, micro-vee filters, Heater Bank. Mixing Box complete with drain connections with anti-vibration mounting and with VFD compatible motor of following capacities: 6000 CFM * 120 mm WG S.P. with 6 Row Deep Cooling Coil for Operation Theatre.with Electrical control Panel for AHU with all controls,With Shead For AHUas directed engineer incharge and approved by architect incharge "
"ELECTRICAL PANEL : Electrical panel for AHUs with RYB Indicators, The Panel should consist of Incomer MCCB, Contactors, DOL / Star - Delta starters , Relays, Push button ( On/Off ), Indicating Lamps ( Start / Stop / Trip )etc. for Package AC unit , Exhuast unit Motor, Heaters, pre programmed VFD of reputed make with higher rating with VFD Bypass provison on panel Panel should have control logic for following; i) Heater operation ii)Outdoor AC timer AHU electrical panel should be IEC 61439-1 compliant"as directed engineer incharge and approved by architect incharge
"Surgeon Control Panel: Supply, Installation, Testing and Commissioning of Tile based and Membrane Type Surgeon Control Panel, mounted flush in the theatre wall, comprising of the following: 1 No. Day Time Clock 1 No. Elapsed Time Clock 1 Set ON/Off & Dimmer for Peripheral Lights 1 Set Digital Medical Gas Indicator 1 Set indicator for Temperature and Humidity display 1 No. Hands Free Telephone Conforming to IEC 60601-1 STANDARDS Note: Gas Sensors will be provided by the MGPS vendor / Supply, Installation Testing and Commissioing control panel, mounted flush in the theatre wall, comprising of the following: It should be designed to cope with changing technology and equipment in operating environments. Control panel should be user friendly and ease of operating and maintaining purpose.Imported Touch Screen Surgeon Control Panel for Operation Theatres with IPS: It should be flush to wall touch screen application for operating theatres, protected by a glass surface that enhances its features and performance in a critical environment of an operating room, coplanar to the finish panel (with the exception of the panels with metallic finish. Touch Screen Surgeon Control panel is recessed box kit for screen 32" 1 x Hardware and software ki for touch screen, with PC intel NUC, PLC siemens and software. For lighting management with DALI protocol 1 x Capacitive touch screen 32", FULL HD resolution 1 x Humidity and temperature sensor 1 x Differential atmospheric pressure sensor for ambient 1 x Differential atmospheric pressure sensor for filter, will have display for Time elapse clock, Standard Clock, Temperature and Humidity, Clean room luminaries, Telephone, Medical Gas alarms. It should have CE compliance under Class 1 Medical devices directive.Country of Origin Certificate must be submitted from chamber of commerce of the country.
Pressure Relief Damper: Supply, Installation and Commissioning of Pressure Relief Damper having multi 304 graded stainless steel blades to control room air pressure (Air Positive Pressure) as directed engineer incharge and approved by architect incharge
HUMIDITY CONTROL MODULE : energy saving hot gas reheating heat exchanger with necessary PLC Controller, Humidity Sensory and Copper Piping as directed engineer incharge and approved by architect incharge
DIFFERENTIAL PRESSURE GAUGES : analogue Magnehelic gauges with housing box & mounting accessories Range 0 to 30 Pascal as directed engineer incharge and approved by architect incharge
LED Peripheral Lights: Supply, Installation, Testing and Commissioning of Recess mounted IP 45 Protocol, non-hygroscopic LED Peripheral Lights having Size – 600 X 300mm Recessed Lights Luminaire body made of powder coated aluminium The LEDs should be high quaity low wattage and should be flickerless design. The LEDs illumination to be controlled by dimmable ballasts and diffuser should be opaque acrylic material mounted on aluminium powder coated frame. The should be controlled by Conforming to IEC 60601-1 STANDARDS / Supply, Installation Testing and Commissioing Peripherial Light/ Clean-room luminaries , Indigenous It should be fitted outside the air ceiling system area and flush with the ceiling in the operation theatre suitable to required illumination (450-500 Lux) of OT. Peripheral lights should be LED based (Size-2ft x 2ft approx. size ) and clean room luminaries fitted in the frame The fluorescent lamps / Non-hygroscopic high glow low power LED based peripheral lights having high quality low wattage LED lighting system with highly spectacular anodized Aluminum reflectors and optical antiglare system for adjustable light distribution. Luminaire cover made of highly resistant, disinfectant proof laminated safety glass with fine grained surface, glass pane with white powder coated steel frame. Luminaire body made of sheet steel, white, powder coated supplied ready for connection. The reflectors should be of high quality, cleanable and non- deteriorating. Dimmable ballasts of reputed companies to be used and diffuser should be constructed with opaque acrylic diffuser material in aluminum frames. It should have flicker less design with color. Recess frames should be gas tight. The fitting should be flush with the ceiling and should be removable form top or bottom. Lighting units should be properly sealed with the ceiling by means of fillers and beadings so that all lighting units are airtight with ceiling panels. The light fitting should be uniformly and aesthetically distributed on the ceiling to provide uniform illumination in the OR. Peripheral lighting should be done according to IP65 protocol. The luminaries for surface or recess mounting in operation theatres should flush with the ceiling.as directed engineer incharge and approved by architect incharge
Two Plate LED X-Ray Film Viewer - Dimmable: Supply, Installation, Testing and Commissioning of Two Plate dimmable X-Ray viewing screen designed to provide a high level of control luminance without flicker. On/Off and dimming operation should be through integrated PCB. Conforming to IEC 60601-1 STANDARDS / Supply, Installation Twin Plate X Ray Viewer -X-Ray View Panel - 1no. for each OT (inside OT work only) :The system should electrical safety codes for high & low voltage system. The theatre is to be equipped with a 2-plate X-Ray viewing screen. It should be designed to provide flicker free luminance for the film viewing purpose. It should be installed flushed with the theatre wall for hygienic and ease of cleaning purpose. The X-Ray viewing screen should be designed for the purpose of front access. The X-Ray viewing screen should be illuminated by 4 pieces of high frequency fluorescent lamps and the dimming is controlled by the usage of dimming ballast with the PCB that is mounted inside the box. Size of the unit should be not less than 800 x 400 mm. It should have CE compliance under Class 1 Medical devices directive. as directed engineer incharge and approved by architect incharge
Storage Unit: Supply, Installation ,Testing and Commissioning of Storage Unit of size 1666 X 865 X 350 mm having two shelves and made out of same material as the wall cladding material having minimum 5 mm thick glass door and mounted flush with the theatre wall. The storage unit should be continously ventilated by positive Air in the OT. / Supply, Installation Testing and Commissioing Storage Unit Indigenous-Storage Unit should be made out of 0.80 - 1.60 mm thick AISI-304 Stainless steel. The storage unit should be divided 2 or more parts and each part should have individual glass doors with high quality locking system. These doors should be installed on the storage units with the help of imported fittings allowing an opening allowance of 90-100 degree. Each part should be provided with Stainless steel-304 racks which should be completely detachable type. The storage unit should be fitted with 5mm thick glass door and mounted flush with the theatre wall. The storage unit should be continuously ventilated by positive air in the OT through ventilation holes provided at the bottom and top of opposite sides. The dimensions of each storage unit should not be less than height 1800 - 2100mm x width 900 – 1200 mm x depth 300 - 350mm. The storage units should be designed in a way that they are flush with the OT wall panels and the units should be air tight, not allowing any leakage between units and the wall panels.It should be CE compliance.as directed engineer incharge and approved by architect incharge
HPL Double Leaf Manual Swing Door: Supply, Installation, Testing and Commissioning of HPL Double Leaf Manual Swing Door Inside Open able Flush Door of size 1800 X 2100mm having viewing window on the shutter of sizes 300 X 300mm. The Door frame is made of Extruded Aluminium Profile having Gasket to provide Leak less mechanism on three sides; the Door will have drop seal to provide sealing against the floor. Door will have Dorma TS-68 Door Closer, D type Handle and Cylindrical Door lock system. as directed engineer incharge and approved by architect incharge
MAGNETIC Writing Board: Supply and Installation ,Testing and Commissioning of Operating Writing List Board of size (948mm X 648mm) /Supply, Installation Testing and Commissioing Writing Board Indigenous-The writing unit should comprise of flush mounted white laminate board, be opened to create a wall mounted writing surface within the operating room. The white board should be constructed from white laminate board. It should have CE compliance under Class 1 Medical devices directive.Writing Board as operating list Board of size-1000 x 700 x 60 deep should be made of ceramic having magnetic properties and should be flushed to the wall of the operating Room. as directed engineer incharge and approved by architect incharge
"2-Bay Scrub Sink, Automatic cum Manual With Infrared Photo sensor, Digital Timer with user defined Time interval 1, 3, 5 and 10 minutes, 1 no. mixture valve and 2 nos. solenoid valves along with Manual Option Foot Operated mechanism. Anti-splash metal body construction made of Stainless Steel Grade 304 polished finished. The scrub sink is provided with front access panel for ease of maintenance and repairs. 2- Position size 1600 mm long / Supply, Installation Testing and Commissioing 2- Bay Surgical Scrub Station-Stainless Steel Scrub Sink Indigenous : Scrub stations for each operation theatre should have been designed to ensure that surgeons and staff can undergo a thorough aseptic scrub, whether using the count stroke or timed scrub methods. Stainless Steel Scrub Sink. Each fixture is fabricated from heavy gauge, type 304, stainless steel and is seamless welded construction polished to a satin finish. Hands free operation includes infrared sensor with a built-in range of adjustment. User definable settings of 3, 6, 12, 30 and 45 seconds, 1, 3, 5 and 10 minute are available. A thermostatically controlled mixing valve automatically maintains water. It should have a foot operated facility. It should have CE compliance under Class 1 Medical devices directive. as directed engineer incharge and approved by architect incharge
"Anaesthesia Pendant: Supply, Installation ,Testing and Commissioning of Anaesthesia Single Arm Pendant and console made up of High grade Aluminium extrusion, Comprising of - 1 x Arm 800mm having - 1 X drop tube having a carrying capacity of maximum load of 85 kg - Rotation of 330 deg. - 1 x Basic Console - 800mm - 1 x Adjustable shelf (Tray) - 6 x Mains Socket (5/15Amp) Electrical 230V 4 x Medical Gas Terminal & Hose Assembly (1 x Oxy, 1 x Vac, 1 x Air(4bar), 1 x N2O) Note: Gas outlets will be provided by the MGPS vendor" / SITC of Imported Double Arm Anesthesia Pendant --1no. for each OT ( Inside OT work) :The pendant shall comply with all relevant Hospital Technical Memoranda (HTM), Hospital Building Notes (HBN) and British Standards (BS) as well as ISO11197:2009. It shall be CE marked with the notified body number specified. It shall be provided with a copy of the certificate of origin. The system shall be provided as factory assembled modules for single or double arm configurations. The pendant frame shall be constructed from extruded aluminum alloy 6063 T6. The end caps should replicate the profile of the vertical head. The aluminum extrusions used to contrast the pendant shall be of approximate wall thickness not less than 3.5 mm. The external surfaces should be antibacterial paint which ensures 100% shied against infectious agent. The pendant lids shall be removable to allow access to the aluminum sections. Segregation shall be provided within the side sections to ensure that services are not accessible when removing the lids. The arm section should present at last two points with a minimum thickness of 170 mm in order to guarantee adequate load bearing of the complete system. The arms will be supplied with ABS heads with LED backlighting signaling. The pendant shall have possibility to mount directly on the body DIN rails for accessories if needed at least two joints of the arms with brakes, electromagnetic barke released. It should have 2 arms 1000mm and 900mm total 1900mm. It should have 180kgs weight bearing capacity of the arms. It should have not less than 180 kgs for 1900 mm total length double motorized arm. It should one vertical 1200mm column to mount gas outlets and electrical. It can rotate from 0 to 330 degree. The control of air brakes must be done using the holder release. All shelves and drawers shall be in acrylic material, 100% non-porous for perfect hygienic control. In case of motorized system the travel time shall be of 27 seconds with a +/- 10% tolerance. It should be supplied as a fully wired and tested module. The devices are made in compliance with EC CERTIFICATE 1548/MDD Directive 93/42/EEC concerning medical devices Annex II with certification CE0051. The equipment should be considered class IIb. It should be IP 20 Classification according to the degree of protection against penetration of liquids and external agents. It should have protection provided on external power circuit which provides adequate protection with circuit breakers or fuses dimensioned accor¬ding to the power indicated on the label. This shall be supplied in compliance with the 93/42/CE regulation. Pendant shall fully meet the essential requirements for emissions and immunity as defined within BS EN 60601-1-1 and ISO standards. It should have vertical pole made of stainless steel with support of aluminum and IV stand with 4 Hooks.It should have one Shelf BIOCLEAN made of Solid Material for ceiling pendant with handle and 2xDIN rails (L530xW460mm) (capacity load 40Kg). It should have Electromagetic Brakes with LED barke lights , 1500mm double column length, 1000 mm and 800mm with moveable arms with 330 deg. Horizontal movement. Double Arm Anesthesia pendant. The weight carrying capacity of the arm should not be less than 180 KG. Each arm should be capable of 330 degrees of rotation, which can be easily adjusted to suit the desired mode of operation. The arms may be fitted with electromagnetic brakes to prevent inadvertent movement. It should have pre piped gas outlet points with NIST connection and manometer Preferably, Should have breaklight indicator LEDs. The Pendant Service Head should be supplied with medical gas terminal units and 6/16amps. Sockets. Each pendant should have:Pre piped 6nos. HTM02-01 standards complies BS gas outlets points with NIST connection. Terrminal units shall have gas indexing geometry. Other gas specific indexing geometries are not acceptable. Terminal unit front fascia should be metal and it should be hundred percent metal. Gas specific components comprising the terminal unit second fix shall be manufactured from die-cast zinc alloy or similar hard wearing metal. Plastic components are not acceptable. Terminal units socket castings shall be permanently coated with a low friction fluoropolymer for maximum reliability and service life. The terminal unit socket die-casting shall incorporate a gas indexing pin to overcome the risk of loosening due to rough handling or abuse. The second fix socket shall incorporate a sheer-plane to safeguard the first fix and pipeline in the event of accidental damage or bed jacking. Gas specific components shall incorporate the gas identity marking permanently stamped or cast into the component surface. The first fix shall be all metal construction, with a brass base block and copper stub pipe. The first fix shall incorporate an integral check valve to enable servicing of the second fix and valve seals without isolation of the gas supply. Probe roller pins shall be manufactured from stainless steel. Wall mounted terminal units shall be provided with white ABS mounting box with matching fascia. The mounting box shall have smooth rounded corners to avoid the possibility of injury. A bezel shall be available to cover the plaster edge, provide a neat and easily to clean finish. • Medical Air(4 bar) Outlet– 2,Oxygen-2,• Vacuum Outlets– 2• AGSS Outlets-2 nos.• Electrical Sockets –10 nos.• Shelf with two rails one on each side – 3nos.& 1 Drawer• Infusion pump pole – 2• RGB Control Lighting switch-1no.
Surgeon Double Arm Pendant: Supply, Installation, Testing and Commissioning of Surgeon Double Arm Pendant and console made up of High grade Aluminium extrusion, Comprising of - 1 x Arm 800 & 1 x Arm 800 having a,- 1 x drop tube having a carrying capacity of maximum load of 120 kg,- Rotation of 330 deg.,- 1 x Basic Console - 800 mm ,- 1 x Fixed shelf - 1 x Adjustable shelf ,- 6 x Mains Socket (5/15Amp),- 7 x Medical Gas Terminal & Hose Assembly ,(2 x Oxy, 2 x Vac, 1 x Air(4bar), 1 x Air(7bar), 1 x N2O) Note: Gas outlets will be provided by the MGPS vendorSITC of Imported Double Arm Surgeon Pendant --1no. for each OT ( Inside OT work) :The pendant shall comply with all relevant Hospital Technical Memoranda (HTM), Hospital Building Notes (HBN) and British Standards (BS) as well as ISO11197:2009. It shall be CE marked with the notified body number specified. It shall be provided with a copy of the certificate of origin. The system shall be provided as factory assembled modules for single or double arm configurations. The pendant frame shall be constructed from extruded aluminum alloy 6063 T6. The end caps should replicate the profile of the vertical head. The aluminum extrusions used to contrast the pendant shall be of approximate wall thickness not less than 3.5 mm. The external surfaces should be antibacterial paint which ensures 100% shied against infectious agent. The pendant lids shall be removable to allow access to the aluminum sections. Segregation shall be provided within the side sections to ensure that services are not accessible when removing the lids. The arm section should present at last two points with a minimum thickness of 170 mm in order to guarantee adequate load bearing of the complete system. The arms will be supplied with ABS heads with LED backlighting signaling. The pendant shall have possibility to mount directly on the body DIN rails for accessories if needed at least two joints of the arms with brakes, electromagnetic barke released. It should have 2 arms 1000mm and 900mm total 1900mm. It should have 180kgs weight bearing capacity of the arms. It should have not less than 180 kgs for 1900 mm total length double motorized arm. It should one vertical 1200mm column to mount gas outlets and electrical. It can rotate from 0 to 330 degree. The control of air brakes must be done using the holder release. All shelves and drawers shall be in acrylic material, 100% non-porous for perfect hygienic control. In case of motorized system the travel time shall be of 27 seconds with a +/- 10% tolerance. It should be supplied as a fully wired and tested module. The devices are made in compliance with EC CERTIFICATE 1548/MDD Directive 93/42/EEC concerning medical devices Annex II with certification CE0051. The equipment should be considered class IIb. It should be IP 20 Classification according to the degree of protection against penetration of liquids and external agents. It should have protection provided on external power circuit which provides adequate protection with circuit breakers or fuses dimensioned accor¬ding to the power indicated on the label. This shall be supplied in compliance with the 93/42/CE regulation. Pendant shall fully meet the essential requirements for emissions and immunity as defined within BS EN 60601-1-1 and ISO standards. It should have vertical pole made of stainless steel with support of aluminum and IV stand with 4 Hooks.It should have one Shelf BIOCLEAN made of Solid Material for ceiling pendant with handle and 2xDIN rails (L530xW460mm) (capacity load 40Kg). It should have Electromagetic Brakes with LED barke lights as directed engineer incharge and approved by architect incharge 1500mm double column length, 1000 mm and 800mm with moveable arms with 330 deg. Horizontal movement. Double Arm Surgeon pendant. The weight carrying capacity of the arm should not be less than 180 KG. Each arm should be capable of 330 degrees of rotation, which can be easily adjusted to suit the desired mode of operation. The arms may be fitted with electromagnetic brakes to prevent inadvertent movement. It should have pre piped gas outlet points with NIST connection and manometer, Preferably, Should have breaklight indicator LEDs. The Pendant Service Head should be supplied with medical gas terminal units and 6/16amps. Sockets. Each pendant should have:Pre piped 6nos. HTM02-01 standards complies BS gas outlets points with NIST connection. Terrminal units shall have gas indexing geometry. Other gas specific indexing geometries are not acceptable. Terminal unit front fascia should be metal and it should be hundred percent metal. Gas specific components comprising the terminal unit second fix shall be manufactured from die-cast zinc alloy or similar hard wearing metal. Plastic components are not acceptable. Terminal units socket castings shall be permanently coated with a low friction fluoropolymer for maximum reliability and service life. The terminal unit socket die-casting shall incorporate a gas indexing pin to overcome the risk of loosening due to rough handling or abuse. The second fix socket shall incorporate a sheer-plane to safeguard the first fix and pipeline in the event of accidental damage or bed jacking. Gas specific components shall incorporate the gas identity marking permanently stamped or cast into the component surface. The first fix shall be all metal construction, with a brass base block and copper stub pipe. The first fix shall incorporate an integral check valve to enable servicing of the second fix and valve seals without isolation of the gas supply. Probe roller pins shall be manufactured from stainless steel. Wall mounted terminal units shall be provided with white ABS mounting box with matching fascia. The mounting box shall have smooth rounded corners to avoid the possibility of injury. A bezel shall be available to cover the plaster edge, provide a neat and easily to clean finish.• Surgical Air(7 bar) Outlet– 2,Oxygen-2, • Vacuum Outlets– 2• CO2 Outlets-2 nos.• Electrical Sockets –10 nos.• Shelf with two rails one on each side – 3nos.& 1 Drawer• Infusion pump pole – 2 • RGB Control Lighting switch-1no.
Misc. work Inside OT
Electrical Work inside OT
Sewage Treatment Plant
Estimate No :- 123106-1 of 2022-23 Providing Transformer & DG set to 100 BEDDED SUB DISTRICT HOSPITAL AT SUPE Supplying, erecting, testing, commissioning 22 KV HT metering cubical (compact type) approved by MSEDCL/licensee fabricated with 2mm.(14 SWG) M.S. sheets with supporting angle and channel, painted with powder coating / epoxy paint of required shade copper bus bar size 25x6 mm electronic security lock and heavy duty mechanical lock, with counter meter for measuring no of times the opening of doors, top side cover ( CT,PT cover) interlock with meter doors, epoxy coated 3 nos CT having required ratio between 50/5 A to 100/5 A, VA10, class 0.2S, 22000/V3/110/V3 VA 50, class 0.2 epoxy terminal block suitable for provided trivector meter, and provision for incoming and outgoing cables etc. complete duly tested by licensee with necessary test certificates and erected on provided plinth/ cc foundation
Supplying , erecting & terminating 3 x 185 sq. mm. aluminium 22 kV(E), XLPE armoured cable on wall/ceiling or laid in provided trench / pipe in an approved manner as per specification no. CB-HT
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 75 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing and erecting Heat shrinkable indoor termination kit for 11 kV (UE)/22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Providing and erecting Heat shrinkable out door termination kit for 11 kV (UE)/ 22 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. cable with necessary material as per specification no. CB-JT/HT
Supplying and erecting extendable / non-extendable outdoor type 22 kV 630A, load break isolator switch on provided MS channels / trench / foundation as per specification no SW-HTS / LBS
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working upto 22 kV supply complete.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying and erecting wall hook 225mm projection for keeping fire buckets made out of 15 mm dia. M.S. Rod grouted in wall to a depth of minimum 15cms complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 & CPRI tested having 2 mm thickness upto 3.3 Kv
Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 315 kVA, oil immersed and naturally cooled outdoor type, copper wound transformer, delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40 o C by thermometer in oil and 45 o C by the resistance in winding at full load rating, with HV tapping (with off load tap changer) off Load +5 to - 10 in steps of 2.5%, with standard accessories complete with test certificate with losses below 1077 Watts at 50% load, 3255 Watts at 100% load as per IS:1180 - 2014 energy efficiency level II with necessary permissions of Electrical Inspector, as per specification no SS- TR.
Making transformer plinth (1.5 x 1.5 x 1.5) m in size with necessary excavation in ground with 150 mm. thick M- 10 PCC at the bottom and top and 250 mm. thick, burnt brick wall constructed at periphery and remaining hollow portion shall be filled with 40mm hard broken aggregate. External surface duly plastered by 12 mm thick including watering etc complete.
Supplying, erecting and commissioning of diesel generating set with alternator of 200 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited, self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level upto 75 dB at 1.0 m, provided with first filling of oil, diesel etc. as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of Microprocessor based AMF panel suitable for diesel generating set of above 180 kVA upto 200 kVA capacity Single/Three phase, 230/415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GENAMF.
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).CSR No. 16-3-5 4.508*1.91*0.7(m)
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 800 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 600 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting 50 x 50 x 6 mm angle iron as corner support 2m long fixed at the middle of the fencing frame and the other side inclined at 30 degree angle, in cement concrete foundation of 15 x 15 x 40 cm complete duly painted with one coat of red oxide and two coats aluminum paint complete.
Supplying and erecting copper strip of required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no. EA-EP. CSR No. 9-2-2
Providing earthing with copper earth plate size 60 x 60 x 0.315 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover with minimum 25 kg Carbon based environment friendly back fill Ground Enhancing compound complete with all materials, testing & recording the results as per specification no ESE -LA
Supplying and erecting mini feeder pillar triple pole with 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A consists of aluminium bus bar 500V 300A complete erected in 14 gauge CRCA sheet box with supporting angles, self-locks, gasket and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
Estimate No :- 123106-2 of 2022-23 Providing internal electrification to 100 BEDDED SUB DISTRICT HOSPITAL AT SUPE Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & laying HMS PVC conduit 32 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling asper specification No: WG-MA/CON.
Supplying and erecting UPVC reinforced flexible conduit 25 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
Supplying & erecting mains with 2x1.5 sq.mm HFFR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (NON DSR)
Supplying & erecting green colour earthing with 1x1.5 sq.mm HFFR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (NON CSR)
Supplying & erecting mains with 2x2.5 sq.mm HFFR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW (NON CSR)
Supplying & erecting green colour earthing with 1x2.5 sq.mm HFFR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW (NON DSR)
Supplying & erecting mains with 4x6 sq.mm HFFR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW (NONCSR)
Supplying & erecting green colour earthing with 1x6 sq.mm HFFR copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG- MA/BW (NON CSR)
Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type bell-push with indicator 2 modules 6A / 10A, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16 / 20A with indicator, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type D.P. switch 32A with indicator, duly erected on provided plate and box with wiring connections complete (For AC)
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16Amulti socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type T.V. socket single outlet, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 4 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 6 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
Point wiring for light/fan/bell CONCELED TYPE in min 20 mm ISI marked HMS PVC conduit with 1.5 sq.mm (2+1E) HFFR grade copper wire with modular type switch and required accessories (NON CSR)
Point wiring for independant plug conceled type in min20 mm ISI mark HMS PVC conduit with 1.5 sq.mm. (2+1E) HFFR grade copper wires, modular type switch and socket, earthing and required accessories (NON CSR)
Secondary point wiring for additional light/ bell point, concealed type in min 20 mm PVC conduit with 1.5 sq.mm.(2+1E) HFFR grade copper wires with required accessories as per specification No: WG-PW/CW (NONCSR)
Point Wiring for plug on board concealed type in min 20 mm ISI marked HMS PVC conduit with 1.5 sq. mm. (2+1E) HFFR grade copper wires, modular type switch and socket, earthing and required accessories as per specification No: WG-PW/CW (NON CSR)
Supplying and erecting five star rated energy saving Ceiling fan 230 V, 28W A.C. 50 cycles 1200 mm complete erected in position
Supplying and erecting ISI mark modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete. Note: Add Rs 57/- for additional two module box with double mounting plate if required.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Supplying and erecting fresh air cum exhaust fan of light duty 250 V A.C. 50 cycles 300mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner.
Supplying and erecting LED square / circular 9 to 12W down lighter having pressure die-cast aluminium housing, opal translucent cover, mounting arrangement with board for surface type or spring loaded mounting clips for flush type complete.
Supplying and erecting square shaped CRCA /die-cast aluminium powder coated housing LED panel light (slim edge-lit) 600x600mm suitable for 36 W-40W with provision for plane front frame with translucent cover fixed to the housing complete
Supplying & erecting LED 18W tube light fitting (4 feet) with polycarbonate housing, heat sink, integrated HF electronic driver complete.
Supplying LED concealed type foot / step light with aluminium body for indoor/outdoor application suitable for upto 4W-6W LED including driver and erecting by making necessary arrangement/recess in wall to make it flush with surface.
Providing & erecting 4 Pole MCCB of 600/630 A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB of 200A,415V capacity with short circuit rating 25 kA (Ics=100% of Icu) adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Providing & erecting 4 Pole MCCB upto 100A, 415V, with short circuit rating 25 kA (Ics=100% of Icu ),adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SWSWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A in provided distribution board as per specification no. SWSWR/MCB
Supplying, erecting & marking TPMCB 6 A to 32A in provided distribution board as per specification no. SWSWR/ MCB
Supplying, erecting & marking TPN MCB 6A to 32A, C-series in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B- series (for lighting) in provided distribution board as per specification no. SWSWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, C-series (for motor / power) in provided distribution board as per specification no. SW-SWR/MCB
Providing, erecting and commissioning 4 pole RCCB of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 63A complete as per specification no. SW- RCCB/RCCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 40A complete as per specification no. SW-RCCB/RCCB
Providing, erecting and commissioning 4 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/25A complete as per specification no. SW-RCCB/RCCB
Supplying & fixing CRCA sheet Box with earthing terminals for housing 4 Pole RCCB on iron frame/laminated board complete.
Providing & erecting 4 Pole MCCB of 315/400A, 415V capacity with short circuit rating 36 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/ UV/ trip alarm contact and MCCB should have phase barriers both sides, in provided enclosure on iron /GI frame as per specification no. SW-SWR/MCCB
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 12 poles on iron / GI frame (horizontal busbar type) as per specification no. SW- SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 24 poles on iron / GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted suitable for SPMCB of 36 poles on iron /GI frame (horizontal busbar type) as per specification no. SW- SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP/TP MCBs of 12 poles/4 ways on iron / GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP /TP of 24 poles/8 ways on iron / GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting Intelligent flush mounted panel meter three phase four wire (IPM) input voltage measurement range 50- 550 V AC (P-P) 415V, aux. supply 90-300 V AC/DC, flush mounting 96 x 96 mm, flush mounted (96 x 96 mm) meter constant Wh viewing in LCD multifunction meters in auto scroll mode with voltage, current, frequency, power factor kW, kVA, kVAR, kWh, kVAh, kVARh, phase angle, interrupts, THD, complete with RS 485 communication protocol, class 1 accuracy and wiring connections and mounting hardware on provided panels complete with calibration certificate from manufacturer
Supplying and erecting LT current transformer with bar primary 50/5 to 1000/5 ratio with 15 VA burden erected in provided CRCA box duly secured with insulating materials connected to the meterwith test certificates.
Supplying & erecting LED type indicating pilot lamp with LED colours red / yellow / green, 230 / 250V on provided box / panel with necessary material, wiring & connections etc.
Supplying & erecting LED type indicating pilot lamp with LED colour blue, 230 / 250 V on provided box / panel with necessary material, wiring & connections etc.
Supplying and erecting 125 kVAr, 3 phase, 50 Hz., capacitor duty contactor with de-latching mechanism microprocessor APFC controller with MPP / APP type capacitor with 525 V and having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours with , consisting of suitable steps of MPP /APP type capacitor units with detuned aluminium filter 7% reactors with circuit breaker as main incomer and MCCB for each branch protection, as per specification no CP-ED/APFC
Supplying, erecting & terminating XLPE armoured cable 3½core 400 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 1100 V. 3½ core 185 sq. mm. aluminium conductor with continuous 12.97 sq. mm. (8 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 3½ core 35 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 16 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 4 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 300 mm width & 20 mm height complete with necessary hardware in approved manner.
Providing & erecting Hot dipped galvanized cover suitable for perforated type cable tray manufactured from 18 swg (1.2 mm thick) GI sheet of 150 mm width & 20 mm height complete with necessary hardware in approved manner.
Supplying & erecting on line UPS pure sine wave of 10 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins battery backup, as per specification no. AP-UPS
Supplying, erecting, testing and commissioning self contained water cooler 230/250 Volts 50 cycles nominal cooling capacity of 150 liters/hr and storage capacity 80 liters with partially stainless steel body complete. specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier ( RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps, storage capacity of purified water 7 to 8 litre with activated carbon filter and softener operating on 230 V single phase A.C. supply.
Supplying and erecting storage type horizontal / vertical water heater 15 litres capacity with BEE 5 star rating high impact resistance engineering plastic body on wall / loft complete duly tested and marking sr. no. and date of erection. specification no. AP-WH/STWH
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with ituminous paint in an approved manner with joints required. As per specification no EA-EP.
Supply, Installation, Testing and commissioning of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete. Specification no. EA-MOBI
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying and erecting of any size electrolyte aluminium patti or bar in bus bar chamber / in panel or any other purpose, 500 V with require capacity with 99.9% aluminium purity with fixing arrangement (like lug or bottle type lug) to both the end with high grade polyolefin insulation sleeve complete as per specification no. BCPBB-
Supplying and erecting slotted angles, frames etc. for panel board or any other purposes complete with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority
Supplying and erecting RCC chamber cover with frame 60cmx 45cm medium duty 100kg with lifting arrangement including laying of angle iron frame of angle size as 50 x 50 x6 mm to be fixed / embedded on top of chamber complete.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation in an approved manner.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 200 mm outside dia, double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting LED street light fitting suitable for 60W lamp, including lamp, with PF > 0.95 class IP 65 and above housing of pressure die cast aluminium alloy and heat sink extruded aluminium complete as per specification No FG- ODF/FLS-2.
Providing & erecting 6 m high (clear height) galvanisedoctagonal pole with foundation bolts having bottom of 130mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL.
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole)
Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Supplying, erecting & marking SPMCB 0.5A to 5A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting PVC insulated PVC round sheathed 1.5 sq.mm (30 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 Kv
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP
Estimate No :- 123106-4 of 2022-23 PROVIDING AIR CONDITIONING FOR 100 BEDDED SUB DISTRICT HOSPITAL AT SUPE Supplying, erecting, testing and commissioning 10 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 12 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supplying, erecting, testing and commissioning 14 HP, VRF / VRV air conditioning system, out door unit (ODU) complying type-IV OEM standards working on HFC free refrigerant R410A or other required/suitable green equivalent refrigerant, for cooling capacity delivering 100% at 47 deg. celcius and non stop cooling even at 56 deg. celsius and coefficient of performance (COP) 3.00 to 4.00, modular type horizontal/vertical hot air discharge suitable for total piping length upto 1000 metre operation in cooling mode with inverter based VRF/VRV technology microprocessor based control compressor starter/control panel complete with scroll compressor, air cooled anti corrosive copper condenser coil of suitable shape for increasing maximum heat transfer area, built in oil separator, accumulator and oil receiver, copper tube aluminium fin air cooled condenser, condenser fan with motor suitable for 415V ± 10%, 50 Hz, 3 phase power supply, internal copper refrigerant piping, internal wiring and first charge of refrigerant, etc. all housed in powder coated weather proof cabinet on provided angle iron frame or suitable foundation connected to the system in approved manner complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.3TR (421 cfm) to 1.7TR (586 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based Hi-wall type indoor unit (IDU) of nominal cooling capacity 1.8TR (594 cfm) to 2.2TR (655 cfm) having EER as per BEE standards and specifications with multiple speed evaporator fan with motor, copper tube aluminium fin evaporator coil, washable air filter, insulated drain tray, expansion device, cordless remote control with necessary controls, with 3-core copper flexible cord of required length and electrical terminal to receive power supply, etc. IDU shall have anti-corrosive coating suitable for coastal area. Unit shall be suitable for indoor wall mounting, having an electronic control console, provided with suitable mounting brackets with any additional refrigerant and oil charge as per the requirement during installation, connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 2.0TR ( 618 cfm ) / 2.3TR ( 671 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 3.0TR ( 1100 cfm ) to 3.2TR ( 1165 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supply, installation, testing and commissioning of VRF/VRV based ceiling suspended 4 Way cassette indor unit (IDU) compact / standard size of nominal cooling capacity 4.1TR ( 1218 cfm ) to 5.0TR ( 1624 cfm ) having EER as per BEE standards and specifications, suitable as per site requirement with swing louvers and adjustable blades from sides. Indoor Units complete with in-built drainage arrangements, fan, refrigerant liquid and refrigerant piping, cordless remote control, and fresh air port etc. IDU shall have anticorrosive coating suitable for coastal area complete in all respects, to operate on 1-phase, 230V, 50Hz, AC input supply, consisting with any additional refrigerant and oil charge as per requirement during installation and connected to the system complete.
Supplying, installing, testing and commissioning split type variable speed inverter technology room Airconditioning unit 1 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall mounting type complete with refrigerant R410A/R32 and copper condensor at position. specification no.APAC/ SAC
Supplying, installing, testing and commissioning split type variable speed Inverter technology room Airconditioning unit 2 TR capacity having ISEER minimum 3.50 to maximum 3.99 suitable to operate on 250V, 50 cycles, A.C. supply having 1 no. of air handling unit hi-wall/ floor mounting type complete with Refrigerants R410 A/R32 and copper condenser at position. specification no. AP-AC/SAC
Supplying, installing, testing and commissioning split type room Air conditioning unit with variable speed Inverter technology 2.5 TR capacity with R410A/R32 refrigerant & copper condenser suitable to operate on 230/415V, 50cycles, A.C. supply having 1 no. of air handling unit (Mega spilt) Hi-wall mounting type complete at position. specification no. AP-AC/SAC
Supplying, erecting, testing and commissioning centralised programmable remote contol panel (HMI) touch manager controls minimum 16 system of minimum 64 ODU's can be controlled and up to 992 IDU's can be individually mounted and controlled indoor units having minimum 200 mm size colour LCD touch panel, yearly schedule, power proportional distribution function, temperature limitation, history function complete erected on wall with an arrangement to integrate with provided fire alarm system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 28.6 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 22.2 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 19.1 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 15.9 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 12.7 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 9.5 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying, laying / fixing, testing and commissioning of appropriate nominal refrigerant copper pipe of 6.4 mm dia (OD) for liquid line / suction line supply and return piping of suitable gauge ( hard drawn copper pipe for liquid main line and for refrigerant ) along with necessary supports, hangers, clamps, vibration isolators and fittings such as bends, tees, valves, gauges, strainers with insulation of 19 mm thick elastomeric nitrile rubber along with application of multicoating suitable for use with VRV / VRF piping for protection against mechanical damages, fungal growth, flame spread, water permeance and ultra violet radiations complete with OEM standards of VRV / VRF air conditioning system.
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 12 mm complete
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 16 mm complete.
Supplying & erecting soft drawn copper pipe suitable for refrigeration system having 22 SWG thickness and inner dia / size 22 mm complete.
Supplying and installation of high pressure grade required size copper connection Y or T- Joints / refnet for liquid and suction line complete erected on wall/ceiling with supports/raceways, Nitrile rubber insulation, painting etc. with brazing and testing for leakages confirming the normal operation of the VRV / VRF air conditioning system.
Providing vaccumising the airconditioner system to 200 micron and charging with R-410A/R32 refrigerant for air conditioning unit.
Supplying and erecting UPVC reinforced flexible conduit 25 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
Supplying and erecting UPVC reinforced flexible conduit 31/32 mm in dia. conforming to I.S. with required number of couplings, PVC bushes, check nuts etc. complete.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 28 mm for solar water heater system.
Supplying and erecting elastomeric nitrile rubber / foam tube type sleeves for over coating and insulating on provided PC / copper pipes having 9 mm thickness and inner diameter / sizes 32 mm for solar water heater system.
Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supply, installation, testing and commissioning cordless remote contol having colour LCD panel, real time clock, temperature limitation (16 to 30 degree Cent.), functions like filter clean reminder timer suitable to communicate with wired controller complete.
Supplying and erecting triple pole and neutral distribution board (TPNDB) surface/ flush mounted SP /TP MCBs of 12 poles/4 ways on iron / GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying, erecting & marking FPMCB 40A to 63A in provided distribution board as per specification no. SWSWR/ MCB
Supplying, erecting & marking TPMCB 6A to 32A in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & terminating XLPE armoured cable 4 core 10 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying and erecting PVC insulated PVC round sheathed 2.5sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting PVC insulated PVC round sheathed 1 sq.mm (32 no. x 0.20mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying & erecting HMS P.V.C. conduit 25 mm. dia. With necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Providing & erecting Hot dipped galvanized perforated type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 200 mm width & 75 mm height complete with necessary coupler plates & hardware in approved manner.
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 300 mm width & 100 mm height comprising all required standard accessories.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm with funnel with a wire mesh for watering and brick masonry block C.l. cover complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Estimate No :- 123106-5 of 2022-23 Providing CCTV system in 100 BEDDED SUB DISTRICT HOSPITAL AT SUPE Supplying and erecting HMS PVC conduit 25 mm dia. with PVC accessories on wall /ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC trunking (PVC casing-n- capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 2 modules duly erected.
Supplying & installing HDMI cable low voltage grade as per specification as per specifications having 10 mtr cord length with male/female 19pin HDMI connectors as per requirements complete.
Supplying & erecting HDMI extender over RJ45 Ethernet Cable Cat5e/6/7 60M 200ft complete.
Supplying & installing UTP networking cat-6 cable suitable for LAN / WAN Computer net-working as per specification No. WG-COC/NC
Supplying, fixing, and configuring web smart power over ethernet switch of 24 ports on provided rack or as directed as per specification No. WG-NWC/ENS
Supplying, fixing, and configuring modularised multi-service router as per specification complete.
Supplying, installing & testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 9U wall mount rack (Dimension-DxWxH – 450x550x500 mm) as per specification No. WG-NAS/RAK
Supplying & erecting on line UPS pure sine wave of 1 kVA capacity complete with standard features, along with necessary SMF batteries for 30 mins. battery backup, as per specification no. AP-UPS
Supplying, Erecting Testing & Commissioning of Full HD commercial display DISPLAY-Screen Size 55-inch Aspect Ratio 16:9 Backlight Scanning 100Hz Resolution 1920 x 1080 pixels Viewing Angle178/178° TERMINAL VIDEO IN RCA X 1 AUDIO IN (L/R) RCA Pin Type X 2 HDMI IN HDMI 1.4 X 3 USB Input USB 2.0 X 2 RS232C Yes HDM1 CEO Yes VGA IN Yes PC AUDIO IN Yes (1) (Share with AC)
Supplying Erecting and crmmissioning of Network Video Recorder eL_32'Channels professional series 4K HD Network video /Audio input 16 ch ,Two way audio-1ch RCA Network Bandwidth 320 Mbps,(i/c @O/G),Remot use 128,protoed-p2p,U pup ,NTP,DHO Video /Audio output -HDMIl/ VGA,'1920X1080p / 60H2,1280 X1024/60 Hz,1 28OX7 20 160,1 2MPl8MP/6MP/5MP/'l 08,Recording, Resolation-OP/960P/P'l /2clFlall Audio output-LCH,RCA, l6inch,playback conidor mode Y4lSnE\O-I12116132, Deced format H265,h264,Live view/play back-12MP/8MP/6MP/sMP/4MP/3MP/108, Cay X1 080P@30x1 2MP@25,4X4K@30,8X4MP,@30,16x1080P@ 3oxHard Disk SATA 4S lnterface upto 10 for each HDD,External lnterference & network lnterference 2RJ 45 TO 1000M ' self serial lnterface,-1xR5485,USB-Front panel ,1x usb 20 rear panel -1 alum 16 ch,A16 um out 4 ch,power supply 12V PC Power consumption -12 W,without 1ocnt (+14 fat+131 F)Environment Diamentions -humidity 590% RH (non considering)44o mm x 3 50 mm (1 7.3"x1 3.5"x2.o"XWXDXH)(Weight without HDD)<3. 1 4 kg(6.9216),certification ( 3YearsWarranty)
Supply Installation commissioning of 4 MP Full HD IP Dome /Bullet Camera Image Sensor 1/3" 4 megapixel progressivescan CMOS Effective Pixels 2304 (H) x 1296 (V) Electronic Shutter Speed Auto/Manual 1-1/100000 s Min. Illumination 0.5 lux F2.1 (Color); 0 lux (IR LEDs on IR Distance - nUp to 100 ft (30 m) Day/Night -auto (ICR)/Color/BVV Backlight Compensation BLC/HLC/DWDR White Balance - Auto/Manual Gain Control - Auto/Manual Noise Reduction - 3D Privacy Masking- Up to 4 areas Lens Focal Length- 2.8 mm Horizontal Angle of View 92° 86° 28 Compression H.265 (Main/High/Baseline Profile) /MJPEG Resolution 3 MP (2304X1296) 1080p Main Stream 4 MP ,30 fps 16x Digital zoom 60 fps, Resolution- Verifocal lens, 320 db Corridor Mode Support Network Protocol IPv4/1Pv6 HTTP HTTPS TCP/IP UDP UPnP ICMP IGMP RTSP RIP SMTP NTP DHCP DNS PPPoE DDNS FTP IP Filter QoS Compatibility -nONVIF Profile S CGI Max. User Access 20 users Mobile App - for 'Phone iPad Android Phone and Tablet Power Supply PoE (802.3af) 12 V DC Working Environment -22°F to 140°F (-30°C to 60°C); 10% to 100% RH condensing ingress protection IP 66 VANDAL resistance-IK10 regulatory FCC part 15B CLASS B (3 YEARS waranty)
Supply Erecting testing and commisioning of 4TB HOD Survillance card disk oduct Dimensions 10.2 x 2,5 x 15.2cm item mode numbers ST4000VX007 Memory Storage Capacity 4TB Flash memory installed size 4 TB Digital Storage Capacity 4TB Hard Drive Rotation Speed 5900RPM Survillance DVRs Hardware Interface SATA 6.0 gB/S Graphics Card interface PCI-E Compatible Devies Desktop Buffer size 64 MB (non csr)
Estimate No :- 123106-6 of 2022-23 Providing LAN & Telephone system in 100 BEDDED SUB DISTRICT HOSPITAL AT SUPE Supplying & laying HMS PVC conduit 25 mm dia. With necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & laying HMS PVC conduit 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting PVC trunking (PVC casing-n- capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 1 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting modular type telephone socket one gang with safety shutter ISI mark approved make duly erected on provided plate and box with wiring connections complete.
Supplying, installing, testing & commissioning push button telephone instrument desk top/wall mount unit as per specification complete
Supplying, installing, testing & commissioning approved type Digital key telephone / IP telephone instrument as per specification complete.
Supplying & erecting telephone cable 2 pair with 0.5 mm dia. laid in provided PVC casing / conduit asper specification No.WG-TW
Supplying & erecting jelly filled armoured telephone copper cable 20 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW
Supplying & erecting jelly filled armoured telephone copper cable 50 pair with 0.5 mm dia. laid in provided trench as per specification No. WG-TW
Supplying, erecting & commissioning MDF Box 100 x 100 pairs as per specification No. WG-TW
Supplying & erecting telephone copper cable 50 pair with 0.5 mm dia. laid in provided PVC casing capping / conduit as per specification No. WG-TW
Supplying, erecting & commissioning junction box suitable for 50 pairs as per specification No. WG-TW
Supplying and installing, testing & commissioning of digital (hybrid) type EPABX of 6 x 56 extensions suitable upto 96 extensions complete
Supplying & installing UTP networking Cat-6 cable suitable for LAN /WAN Computer net-working as per specification No. WG-COC/NC
Supplying and fixing 1 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying and fixing 3 meter length, UTP patch cord of Cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring ethernet managed ethernet switch of 24 ports with 2 SFP + 2 combo port and web view/CLI on provided rack or as directed as per specification no. WG-NWC/GBS
Supplying and fixing tool-less Information Outlet (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 6U wall mount rack (Dimension-DxWxH– 450x550x367 mm) as per specification No. WG-NAS/RAK
Estimate No :- 123106-7 of 2022-23 Providing water pumps in 100 BEDDED SUB DISTRICT HOSPITAL AT SUPE Supplying and erecting submersible pumpset of 3.75 KW/5 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 20 to 80 LPM discharge at 91 to 42 m head & (max. efficiency at 68 m head & 50 lpm) discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification no. WP-SMP
Supplying and erecting submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s.A.C. supply, having delivery head from 21 to 7 m and discharge from 200 to 800 Itrs. per minute (Max efficiency at 16 m head & 500 Itr discharge) & pipe of Suction 50mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification no. WP-OSP
Supplying and erecting Centrifugal water pump (Monoblock), 230V, Single phase 50 cycles A.C. supply of 0.75 KW/1 HP with discharge 1.6/2.9 Litres per second (LPS) for head of 9/22 m & 40 mm suction/ 40 mm delivery pipe on provided C.C. foundation as per specification no. WP-CGP
Supplying and erecting flat flexible 3 core 4 sq mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying & erecting Water lavel controller 230/ 415V AC., Four way for under ground & Over head tank operation
Supplying & erecting automatic control panel for 3 Ph, 415 volt, A.c. Submersible/centrifugal pump set upto 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc
Supplying & erecting automatic control panel for 1 Ph, 230 volt, a.c.. Submersible/centrifugal pump set upto 2 HP consisting of DOL starter Of suitable relay range S.P.P., Combined ammeter/ voltmeter, indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection.
Supplying and erecting four pole metal clad ON LOAD change over switch 415V, 40A erected on angle iron / GI frame complete.
Supplying and erecting marine plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying and erecting non return valve 40 mm dia inposition made of gun metal complete.
Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete.
Supplying and erecting 40 mm. dia. gun metal sluice valve at position with necessary materials complete.
Supplying and erecting ISI mark GI pipe 50 mm dia.‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 40 mm. dia. ‘B’ class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting metal work in CRCA sheet with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete
Estimate No : 123106-8 of 2022-2023 Providing fire fighting system in 100 BEDDED SUB DISTRICT HOSPITAL AT SUPE Supplying, installing, testing and commissioning optical type smoke detector complete on box as per specification no. FF- FAS/SD
Supplying, installing, testing and commissioning heat detector complete on box as per specification no. FF-FAS/HD
Supplying, installing, testing and commissioning manual call point (Pill box) with break glass push button in metal enclosure complete as per specification no. FF-FAAS/MCP
Supplying, installing, testing and commissioning hooters with CRCA enclosure complete as per specification no. FFFAAS/ HTR
Supplying, installing, testing and commissioning remote response indicators complete as per specification no. FF- FAAS/RRI
Supplying, installing, testing and commissioning FRLS, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, installing, testing and commissioning of 14 Zones Microprocessor based conventional fire alarm control panel (FACP) with standard accessories complete as per specification no. FF-FAAS/FACP
Supplying and erecting HMS PVC conduit 20 mm dia. with PVC accessories on wall / ceiling as per specification No: WG-MA
Carrying out core cutting of size 3" to 5" dia x 15" length in the C.C./rock/stone wall with the help of specialized core cutting machine in proper manner and finishing the site as original.
Supplying and erecting iron, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Supplying, erecting & terminating XLPE armoured cable 4 core 25 sq. mm. aluminium conductor with continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 95 sq. mm. aluminium conductor with continuous 8.35 sq. mm. (10 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating XLPE armoured cable 4 core 6 sq. mm. copper conductor continuous 5.48 sq. mm. (12 SWG) G.I. earth wire complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Providing & erecting Hot dipped galvanized ladder type cable tray manufactured from 16 swg (1.6 mm thick) GI sheet of 150 mm width & 100 mm height comprising all required standard accessories.
Providing earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint in an approved manner with joints required. As per specification no EA-EP.
Providing Round bottom fire bucket of 9 Litres capacity as per IS : 2546 made out of 24 gauge G.I. sheet with extra handle at bottom duly painted white inside and red outside with FIRE Mark, on provided stand/ wall hook complete.
Providing Floor mounting stand for keeping 4 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 4 hooks and duly painted with one coat of red lead and two coats of silver paint complete.
Supplying & erecting Carbon Dioxide (CO 2 ) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with necessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts grouted in wall complete.
Supplying and erecting ABC powder type fire extinguisher as per IS : 13849 /15683 of 6 kg capacity with necessary clamp for erection on wall.
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of fire service main single stage pump, of 1800 LPM at 76 m head centrifugal type, 50HP (37 kW), 3 phase, 415 volt, 50Hz or of suitable HP complete as per specification no. FF-MFP/SSC
Supplying, installing, testing and commissioning with perfect aligning, proper levelling of jockey pump of 240 LPM at 56m head, 15 HP (11 kW), 3 phase, 415 volt, 50Hz or of suitable HP with suitable stages as per specification no. FF- MFP/JP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 25 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting ISI mark GI pipe 32 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting ISI mark GI pipe 40 mm. dia ‘C” class at position with accessories complete. Specification no. CW-PLB/GP.
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 50 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 65 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 75/80 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 100 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 150 mm dia with necessary fittings complete as per specification no. FF-PP
Supplying and erecting G.I. pipe above ground of ‘C’ class ERW of size 200 mm dia with necessary fittings complete as per specification no. FF-PP
Providing coating of bitumen paint & 4mm thick wrapping for underground 100 mm ring main of fire fighting system.
Providing coating of bitumen paint & 4mm thick wrapping for underground 150 mm ring main of fire fighting system.
Supplying and erecting cast iron foot valve ball type/flap type of size 80 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying and erecting cast iron foot valve ball type/flap type of size 200 mm dia with strainer for negative suction complete as per specification no. FF-VL/FV
Supplying & erecting cast iron double flange butterfly valve of size 50 mm dia. complete as per specification no. FF-VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 75/80 mm dia. complete as per specification no. FF- VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 100 mm dia. complete as per specification no. FF- VL/BFV
Supplying & erecting cast iron double flange butterfly valve of size 150 mm dia. complete as per specification no. FF- VL/BFV
Supplying and erecting cast iron double flange NRV of size 75/80 mm dia complete as per specification no. FF- VL/NRV
Supplying and erecting cast iron double flange NRV of size 200 mm dia complete as per specification no. FF-VL/NRV
Supplying & erecting gun metal gate valve of size 25 mm dia complete as per specification no. FF-VL/GV
Supplying and erecting stainless steel single outlet hydrant valve fitted with necessary accessories complete as per specification no. FF-VL/HV
Supplying & installing one piece moulded HDPE / fibre water tank for negative suction only, having capacity 1000 litres fitted with necessary accessories complete as per specification no. FF-FFA/PT
Supplying and installing wall mounting swinging Hose reel drum fitted with 19 mm dia. 30m long high pressure polypropylene (Polyhose) fitted with necessary accessories complete as per specification no. FF-FFA/HV
Supplying fire fighting reinforced rubber lined (R.R.L.) hose pipe, 63mm dia, 15m in length, fitted with necessary accessories complete as per specification no. FF-FFA/RRL
Supplying & erecting stainless steel branch pipe 63 mm dia fitted with 20 mm dia detachable hexagonal nozzle complete as per specifications no. FF-FFA/NZ
Supplying and erecting fire brigade header of 150 mm dia, for supplying water in fire tank complete as per specification no. FF-FA/FBC
Supplying and erecting fire brigade header (Siamese connection) of 150 mm dia for supplying water to wet riser system complete as per specification no. FF-FFA/SMC
Supplying and installing air vessel of 300 mm dia 1.5m in height M.S. tank installed inside pump house / on terrace complete as per specification no. FF-FFA/ACT
Supplying and erecting 20/25mm dia gun metal air releasecock, with necessary G.I. coupling to be fitted on top of air vessel or on wet riser complete as per specification no. FF-FFA/ARV
Supplying and installing pressure gauge of 100 mm dia., 0- 300 PSI or 0-14 kg per cm square fitted with 12/15 mm dia. pad cock valve, and G.I. pipe, elbow etc. complete as per specification no. FF-FFA/PG
Supplying and installing pressure switch with 12/15 mm dia isolation valve, G.I. nipple, elbow, etc complete as per specification no. FF-FFA/PS
(Supplying and erecting one no. brass orifice plate having 6 mm. thickness, 140 mm outer dia and required/proper diameter of inner hole at every single outlet hydrant valve as per specification no. FF-FFA/OP
Supplying and erecting M.S./CRCA cabinet for housing Floor Hydrant valve, hose pipe, hose reel and branch pipe (size 1000 x 736 x 736 mm.) made from 16 SWG sheet and angle iron 25 x 25 x 4 mm. having front doors with viewing glass (8"x6") and locking arrangement with necessary fixing material such as rubber bidding etc. duly painted in post box red colour.
Supplying, installing, testing and commissioning FRLS XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying, erecting, testing and commissioning amplifier 120 W for public address system suitable to operate on 230 Volts A.C. / 12 Volts D.C. supply complete as per specification no. FF-PA/AFR
Supplying, erecting, testing and commissioning sound column 15 Watts complete as per specification no. FF-PA/SOC
Supplying, erecting, testing and commissioning microphone complete as per specification no. FF-PA/MIC
Supplying, erecting, testing and commissioning stand for microphone complete.
Supplying, erecting, testing and commissioning of 1.5 sq mm speaker wire complete.
Supplying, erecting, testing and commissioning of 15 mm (½") dia. NBCM Body chrome finished quartzoid bulb sprinkler having 68º C fixed temperature rating with deflector disc of conventional construction complete as per specification no. FF-SPR
Supplying, erecting, testing and commissioning vane typewater flow detector suitable for detecting flow of water in wet sprinkler pipe of main line or branch lines of 75/80 mm dia having following features 1) Visual switch activation 2) Rugged switch assembly 3) Heavy duty aluminium pipe saddles 4) Durable metal enclosure 5) Steel U bolts for secure mounting 6) Two SPDT ( Single pole double track ) synchronised switches 7) serviceable without draining pipes
Supplying and installing of Horizontally split Case type centrifugal double Suction long Coupled base mounted Single stage pump Engine driven split case in Cast iron bronze fitted construction Specifically designed for quiet operation. Diesel Engine water cooled( heat exchanger) type and complete with accessories including auto start control panel batteries as per Specification. Rate also shall be inclusive Of Pressure relief vaive and double walled Diesel tank of rated Capacity Engine Exhaust pipe insulation.The impeller shaft shall be a Solid stainless steel shaft. Pump shall be equiped with in direct contact with the pump shaft. Impeller shall be of enclosed double suction type made of bronze both hydraulically and dynamically balanced keyed to the shaft and fixed in axial position. Engine shall meet scheduled horsepower speed voltage and enclosure design. Pump and Engine shall be factory aligned and shall be realigned after installation by the manufacturer's representative. Flow rate:1800 LPM at 70 m Head 60 HP (45 KW ). 2960 RPM. (NON-CSR)
Supplying and erecting fire resistant mortar (20 kg) with fire resistance class S90 as per National Electrical Code (NEC) SP30-2011 suitable to seal the openings with all kinds of cables, pipes and cable support system in steel and aluminium and plastic profiles ( Except hollow core conductors). The residual openings shall be closed with filler, as per specification no. FF-FRM
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).
Supplying & installing auto glow ( Viewing upto 15 Mtr length) flre Signages viz Fire Hydrant, Fire Extinguishers, Fire Exit , Fire Door , Fire Hose Box etc. Size of 450 x 150m (NON CSR)
Supplying & installing auto glow ( Viewing upto 15 Mtr length) fire Signages viz Fire Hydrant, Fire Extinguishers , Fire Exit , Fire Door , Fire Hose Box etc. Size of 300 x100m (NON CSR)
Supplying & installing auto glow ( Viewing upto 15 Mtr length) fire Signages viz Fire Hydrant, Fire Extinguishers , Fire Exit , Fire Door , Fire Hose Box etc. Size of 600 x 200mm (NON CSR)
Supply, lnstallating, Testing & Commissioning of UL listed armoured type flexible sprinkler hose. Length 1000mm upto 1500mm as per site condition. ( Non CSR )
Spectrum Infrastructure
SAURABH CONSTRUCTION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid