Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.4 LAccepted-Finance 197 4 KANTADANGA ROAD P O FINGAPARA KANKINARA NORTH 24 PARGANAS PIN 743129 | KANKINARA | NORTH 24 PARGANAS | WEST BENGAL | 743129 | ₹1.4 L | L1 | Accepted-Finance that the bid
is L1 |
| 2 | L2₹1.4 LRejected-Finance 24 C GOABAGAN LANE KOLKATA 700006 WEST BENGAL | KOLKATA | KOLKATA | WEST BENGAL | 700006 | ₹1.4 L | L2 | Rejected-Finance that the bid
is not L1 |
| 3 | L3₹1.4 LRejected-Finance 14 BEPIN BEHARI GANGUALY STREET KOLKATA 700 012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | ₹1.4 L | L3 | Rejected-Finance that the bid
is not L1 |
| 4 | L4₹1.4 LRejected-Finance BASUDEBPUR BELKHALI HOWRAH PIN 711 322 | HOWRAH | HOWRAH | WEST BENGAL | 711322 | ₹1.4 L | L4 | Rejected-Finance that the bid
is not L1 |
| 5 | L5₹1.7 LRejected-Finance 7A BENTINCK STREET KOLKATA 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | ₹1.7 L | L5 | Rejected-Finance that the bid
is not L1 |
| Sl No | Description | Qty | Unit | ALPHA ELECTRICALS L2 | Computer Gallery L4 | PERFECT IMAGE SOLUTIONS L5 | ASSOCIATED ELECTRICAL CONST CO. 1963 PVT.LTD L3 | M/S R. K. ENTERPRISE L1 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Through Checking of existing Fire Detection system installed at MCH building under MCHES-II/ PWD by deputing requisite technicians and engineers as per requirement & rectified the all fault. Software commissioning charge in case of any software issue / Device Removing from Detection line / Re-Commissioning. This is including all necessary tools, tackles, ladder etc. & issue of fit certificate. | 2 | item | 7,000 ₹14,000 | 15,000 ₹30,000 | 20,000 ₹40,000 | 11,000 ₹22,000 | 15,000 ₹30,000 |
| 2.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors.
(Approved Make : Seimens / Honeywell- Notifier/ Bosch)
The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens) | 10 | Nos | 4,000 ₹40,000 | 4,800 ₹48,000 | 5,000 ₹50,000 | 4,100 ₹41,000 | 2,200 ₹22,000 |
| 3.00 | Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator.
(Approved Make : Seimens / Honeywell- Notifier/ Bosch)
The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens) | 1 | Nos | 3,500 ₹3,500 | 4,500 ₹4,500 | 5,000 ₹5,000 | 4,000 ₹4,000 | 4,500 ₹4,500 |
| 4.00 | Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required.
(Approved Make : Seimens / Honeywell- Notifier/ Bosch)
The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens) | 1 | Nos | 5,000 ₹5,000 | 6,000 ₹6,000 | 7,000 ₹7,000 | 5,000 ₹5,000 | 3,000 ₹3,000 |
| 5.00 | Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS approved) approved.
(Approved Make : Seimens / Honeywell- Notifier/ Bosch)
The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens) | 1 | Nos | 4,000 ₹4,000 | 9,000 ₹9,000 | 9,000 ₹9,000 | 10,200 ₹10,200 | 5,000 ₹5,000 |
| 6.00 | Supply, Installation, Testing & Commissioning of Addressable Monitor Modules ( VDS approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required.
(Approved Make : Seimens / Honeywell- Notifier/ Bosch)
The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens) | 2 | Nos | 3,000 ₹6,000 | 6,000 ₹12,000 | 6,000 ₹12,000 | 5,000 ₹10,000 | 4,000 ₹8,000 |
| 7.00 | Supply, Installation, Testing & Commissioning of Addressable Relay Modules (VDS approved) for switching / integration of Lift / AHU etc complete as required. (Approved Make : Siemens/ Honeywell-Esser/ BOSCH) (Approved Make : Seimens / Honeywell- Notifier/ Bosch)
The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens) | 2 | Nos | 3,000 ₹6,000 | 1 ₹2 | 4,000 ₹8,000 | 2,000 ₹4,000 | 3,500 ₹7,000 |
| 8.00 | Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS approved) having 2 Nos. red coloured LED lamps including connections etc.
(Approved Make : Seimens / Honeywell- Notifier/ Bosch)
The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens) | 10 | Nos | 270 ₹2,700 | 100 ₹1,000 | 100 ₹1,000 | 100 ₹1,000 | 1,200 ₹12,000 |
| 9.00 | Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab/KEI) with necessary arrangement as per G.S. on wall/ceiling. | 400 | Mtr | 85 ₹34,000 | 75 ₹30,000 | 75 ₹30,000 | 75 ₹30,000 | 60 ₹24,000 |
| 10.00 | Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make,medium quality] on wall, ceiling with saddles and other accessories as required and mending good damages to building works
20mm size | 400 | Mtr | 62 ₹24,800 | 10 ₹4,000 | 10 ₹4,000 | 35 ₹14,000 | 50 ₹20,000 |
Tender Value
₹1.4 L
EMD Value
₹2,900
Closing Date
5 Mar 2026, 1:00 pmClosed
EE-II KNHED PWDte.
OFFICE OF THE EXECUTIVE ENGINEER Kolkata North Health Electrical Division, P.W.Dte. KIT Building Annex, 4thFloor,P-16, India Exch. Place Extn., Kolkata700073
Renovation work and Modification of the ART Centre Under Kolkata Medical College and Hospital. (Part -C) Fire Detection System installation work
2026_WBPWD_1011265_1
WBPWD/EE-II/KNHED/NIQ-89/ 2025-26
Open Tender
FIRE FIGHTING ORG
15 days
Kolkata
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,900
OFFICE OF THE EE KNHED PWDte.
20 May 2026
19 Feb 2026
9 Mar 2026
19 Feb 2026
5 Mar 2026
26 Feb 2026
25 Feb 2026
Through Checking of existing Fire Detection system installed at MCH building under MCHES-II/ PWD by deputing requisite technicians and engineers as per requirement & rectified the all fault. Software commissioning charge in case of any software issue / Device Removing from Detection line / Re-Commissioning. This is including all necessary tools, tackles, ladder etc. & issue of fit certificate.
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Multisensor detector IP 42 ( VDS approved ) with inbuilt optical smoke sensors and heat detector sensor with inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. The detector should have 360 degree optical view with single / multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Seimens / Honeywell- Notifier/ Bosch) The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens)
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Heat detector IP 42 ( VDS approved ) with combination of fixed type & Rate of Rise of Temperature feature. Detector shall have maimum triggering temperature programmable from 60 deg. C to 80 deg. C., having high level of immunity to electromagnetic influances and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : Seimens / Honeywell- Notifier/ Bosch) The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens)
Supply, Installation,Testing & Commisioning of Addressable Manual Call Point ( VDS approved ) with in built short circuit fault isolator as per NFPA style 7 wiring complete as required. (Approved Make : Seimens / Honeywell- Notifier/ Bosch) The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens)
Supply, Installation, Testing & Commissioning of IP Addressable Loop Powered Hooter ( sound output of minimum 90 db ) cum strobe (strength of light 10 cd) complete with inbuilt short circuit fault isolator. Degree of protection IP65 ( VDS approved) approved. (Approved Make : Seimens / Honeywell- Notifier/ Bosch) The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens)
Supply, Installation, Testing & Commissioning of Addressable Monitor Modules ( VDS approved ) for monitoring Flow switches / Fire exit doors / AHU/ Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contact with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 42 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Approved Make : Seimens / Honeywell- Notifier/ Bosch) The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens)
Supply, Installation, Testing & Commissioning of Addressable Relay Modules (VDS approved) for switching / integration of Lift / AHU etc complete as required. (Approved Make : Siemens/ Honeywell-Esser/ BOSCH) (Approved Make : Seimens / Honeywell- Notifier/ Bosch) The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens)
Supplying, installation, testing and commissioning of LED type Response Indicator ( VDS approved) having 2 Nos. red coloured LED lamps including connections etc. (Approved Make : Seimens / Honeywell- Notifier/ Bosch) The new devices should be matched with the existing 2/4/6 loop addressable Fire panel (make-- Seimens)
Supply & Laying of 2 Core 1.5 sq.mm FRLS shielded copper Cable (For Loop) (Make. Finolex/Gloster/ RR Kable/Polycab/KEI) with necessary arrangement as per G.S. on wall/ceiling.
Supplying and fixing PVC Rigid Conduit 'FR' [Precision Make,medium quality] on wall, ceiling with saddles and other accessories as required and mending good damages to building works 20mm size
[ Rates should be Quotated inclusive of all taxes & duities and L.W.C. @ 1% as applicable ]
Please Enable Macros to View BoQ information
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.45 MB
BOQ_2483132.xls
BOQ • 0.35 MB
2911.pdf
Tender Documents • 1.46 MB
suspension.pdf
Additional Documents • 2.91 MB
Download all tender documents and submit your bid