| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.9 CrAccepted-AOC 21 PASCHIM VIHAR EXTENSION NEW DELHI 110 063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹4.9 Cr | L1 | Accepted-AOC Being lowest and reasonable |
| 2 | L2₹6.4 Cr+₹1.5 Cr (31.7%)Rejected-Finance | ₹6.4 Cr+₹1.5 Cr (31.7%) | L2 | Rejected-Finance Not being lowest |
| 3 | L3₹5.7 Cr+₹82.0 L (16.8%)Rejected-Finance 3 1 4 GOPINATH BAZAR DELHI CANTT 110 010 | NEW DELHI | DELHI | 110010 | ₹5.7 Cr+₹82.0 L (16.8%) | L3 | Rejected-Finance Not being lowest |
| 4 | Rejected-Technical | - | - | Rejected-Technical Not approved due to no adverse remarks in WLR |
| 5 | Rejected-Technical 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | - | - | Rejected-Technical Not approved, does not fulfils the eligibility criteria |
Tender Value
₹7.4 Cr
EMD Value
₹6.9 L
Closing Date
25 Jan 2025, 6:00 pmClosed
HQ Chief Engineer Delhi Zone
HQ Chief Engineer Delhi Zone Delhi Cantt-10
COMPREHENSIVE WORK FOR SEWAGE MANAGEMENT FLOOD MITIGATION AND MANNING MAINTENANCE OPERATION AT HQ SIG COY UNDER GE U WATER SUPPLY DELHI CANTT PARA 36 WORKS
2024_MES_669882_3
CEDZ/TOKEN-23 OF 2024
Open Tender
Civil Works
Lump-sum
4200 days
Delhi Cantt-10
As per NIT
10 documents required · 10 mandatory
₹3,000
GE U Water Supply
₹6.9 L
Yes
23 Apr 2025
3 Jan 2025
27 Jan 2025
3 Jan 2025
25 Jan 2025
11 Jan 2025
3 Jan 2025 - 8 Jan 2025
Amount
Lump sum price worked out by the contractor for Schedule 'A' Section-I (Bldg Work) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-II (Site Clearance) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-III (Exacavation and Earth Work) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IV (Road, Path and Culvert) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-V (Compound, Boundary Wall and Gate) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VI-A (Sewage Disposal) (B/R Portion) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VI-B (Sewage Disposal) (E/M Portion) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VII (External Water Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-VIII (External Electric Supply) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-IX (External Wayet Supply (RWH)) (Ref pre priced Schedule attached seperately)
Lump sum price worked out by the contractor for Schedule 'A' Section-X (Manning and Operation of STP) (Ref pre priced Schedule attached seperately) Note :- (a) Pre-priced amount inserted against Srl No.11 is minimum amount to be quoted by the contractor against Manning & Operation of STP. Contractor's profit and anticipated rates for next 10 years has not been considered in this amount. Contractor shall consider these aspect while quoting rates for this items. No claims whatsoever in respect of this item shall be entertained. (b) In no case, the contractor shall pay the wage which are less than the minimum wage including other benifits as prescribed by the Govt from time to time.
Description of Work / Item(s)
Amount
STP (Sewage Treatment Plant) Designing (hydraulically, structurally & aesthetically), providing, constructing, hydraulic testing, commissioning and giving satisfactory trials of STP 500 KLD Package type of any technology meeting output criteria as per DBR report Srl No. 2.2 as recommended by OEM technology , foundation for all E/M equipments, associated piping work with required valves, electrical control panel with interconnecting cable etc. complete as turnkey job with all involved electrical, digital and mechanical works as per detailed specifications for civil, electrical and mechanical components with all duties and taxes complete all as per DBR. Online monitoring system of the out put parameter shall also be provided, complete all as specified and directed.
EXTERNAL WATER SUPPLY
Excavation in trenches by cutting of road crossing PCC hard standing for taking out/laying of pipe including making good the existing surfaces with same finish to match the original finish, complete all as specified & directed.
M&L for MS pipe header 300mm dia size 6.3mm thick 6 mtr length with flanged ends closed with end plates not less than 20 mm thick fixed with and including provision of 1 incoming and 4 outgoing connection ( 200 mm dia -01, 150mm dia -03 ) with flanged end including painting with two coat of red oxide primer, complete all as specified & directed.
Supply & fixing PPR Gate valves (brass insert), of following sizes, complete all as specified & directed.
Supply and fixing Bib taps of PTMT 15 mm bore, any tint, high pressure screwed for male/female threaded, complete all as specified & directed.
Supply and fixing Bib taps of PTMT 20 mm bore, any tint, high pressure screwed for male/female threaded, complete all as specified & directed.
M&L Construction of valves pit chamber having intermal dimension 120 cm x 120 cm x 120 cm (internal height) using PCC (1:4:8) 40mm graded stone aggregate for foundation 15 cms, thick, 23 cm thick wall in CM (1:4), 10mm thick rendering all around the brick work in cm 1:6, PCC (1:2:4) type B1 coping with 20mm graded aggregate for grouting MS frame including 3mm tick MS top sheet cover with locking arrangement including 50mm pad lock with double key angle iron including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primers including necessary excavation & earth work in any type of soil, returning filling in and removal of surpuls soil to a distance not exceeding 50 mtrs all as specified and shown on drawings and including demolition/ dismentling of existing valve chamber, complete all as specified and directed.
M&L for Making bore hole under the road, payment, hard standing any type of soil through trenchless technology using ultra sounding technique, HDD and necessary machine including HDPE pipe of 250 mm dia suitable for 0.4 MPA working pressure, complete all as specified and directed.
Supply and fixing CI foot valve confirming to IS-4038 , 100 mm dia, complete all as specified and directed .
Supply and fixing pipe ERW steel including specials, nominal dia. 200 mm as per IS:3589 (1981) thickness 6.0mm, complete all as specifed & directed
Supply and fixing, MS flanges of size 200 mm bore bore not less than 16 mm thick duly welded on ends of MS pipe, complete all as specified and directed .
M&L for Flanged Joints of size 200 mm dia with rubber or fibre board gasket including nuts, bolts and double washers, complete all as specified and directed .
Supply and fixing pipe ERW steel including specials, nominal dia. 100 mm as per IS:3589 (1981) thickness 6.0mm, complete all as specifed & directed
Supply and fixing, MS flanges of size 100 mm bore bore not less than 16 mm thick duly welded on ends of MS pipe, complete all as specified and directed .
M&L for Flanged Joints of size 100 mm dia with rubber or fibre board gasket including nuts, bolts and double washers, complete all as specified and directed.
Supply and laying Ductile iron pipe 200mm bore of class K-7 with spigot and socket ends suitable for tyton jointing (push on rubber gasket joint) with cement mortar lining inside and bituminous coating outside, complete as per IS:8329, laid in trenches, testing after completion, complete all as specified & directed.
Supply and fixing electromagnetic flow meter of size 150 mm dia, IP-68, complete all as specified & directed.
Supply and fixing non clog submersible pump set with motor 15.0 HP, 1450 RPM, 415 V, 3PH, outlet 150mm, head 14 mtr, 2000 LPM including cable connection, testing complete all as specified and directed.
EXTERNAL ELECTRIC SUPPLY
Supplying, installation, testing and commissioning of water cooled silent diesel engine driven generating set 415 Volt , 3 phase 4 wire, engine QSB4.5/ QSB4.52 or equivalent series (CPCB IV + Compliance), 4 Cylinder, in Line 4 stroke, radiator cooled and alternator-brushless type screen protected revolving fields self excited alternator confirming to IS/IEC 60034-1 complete with foundation (as per OEM design), control panel with AMF Functionality controllers of Makes from the OEM, necessary meter and sound proof canopy as per CPCB norms of capacity after all derating factors net of not less than 82.5KVA /66 KW, complete all as specified & directed.
Supplying, installation, testing and commissioning of Out door type of factory fabricated LT panel made out of 3.15 mm thick CRCA sheet and angle iron of size 40 x 40 x 5 mm floor mounted type with copper bus bar of capacity 300 Amp - 4 Nos including two coats of spary synthetic enamel paint over a coat of red oxide, including multi function meter showing voltmeter, ammeter, PF with necessary CTs & PTs, , phase indication lamps for three phase system, control panel & power panel wiring, cable alleys at both side, confirming to IS:8623, IEC:60439 & CPRI Approved, protection class IP54 with the accessories housing. The panel shall be provided with separate compartments for each switch gears with hinged door including interlocking with switch gearswith the following switch gears:- (i) incoming MCCB 4 pole , 415 V, Adjustable type, 200Amps with breaking capacity 36KA Incoming-01 No (ii) MCCB TP 415 V, fixed type, 100 Amps, 16 KA -01 No (iii) MCCB TP 415 V, fixed type, 63 Amps, 16 KA -04 No (iv) MCB C series type TPN 63 Amps, - 04 Nos (v) Change over 125 A, 4 P -01 Nos (vi) MCB SPN 32 Amps- 02 Nos
M&L for PCC cable route indicator of size 45cm x 25cm x 7.5cm duly grouted 15 cm below ground level in PCC 1:4:8 type D-2, top edges chempered and writing HT 11KV CABLE duly grouted on both sides, complete all as specified & directed.
M&L for boaring under holes by manually or machinery not less than 1.5 mtr deep without damage the existing structure, complete all as specified & directed.
Supply & fixing junction box of size 300x300x250 mm made of MS Sheet 1.6mm thick, front door openable with fixing screw painting with two coats of synthetic enamel power coated paint over a coat or red oxide including alumnium bus bar 4 Nos of size 25x3mm mounted on epoxy based post insulators and drilled holes for connection including 01 Nos MCB SPN 6 Amps, 2 Nos MCBs 06 amps including magnetic lock system all as required and fixed to poles using MS strip of size 32x6mm and nuts & bolts of required size, complete all as specified & directed.
Supply & fixing LED 70 Watt street/security light, IP 65 , connection with 1 Sqmm twin core PVC insulted copper conductor passing through GI pipe light grade of size 15 mm dia from junction box to LED security light including GI bracket 1.2 Meter long 32 mm dia medium grade bend to safe, clamp, nut bolt & washer etc, complete as specified & directed.
EXTERNAL WATER SUPPLY (RWH)
M&L for brick aggregate of size 40 mm to 63 mm. The first layer in rain harvesting pit is to be provided with brick aggregate and to be provided in the layer upto 400 mm, complete all as specified & directed.
M&L for gravells 05-10 mm to be provided for second layer of rain water harvesting pit and is to be provided upto the layer of 400 mm, complete all as specified & directed.
M&L for Trial borewell of 200 mm dia upto 200 mtr deep below the ground level in any kind of soil/strata including hard stone/boulders, electronic logging, MS cap, MS flt iron clamp, reducing socket etc, complete all as specified & directed.
M&L for Development of trial bore by reaming upto 300 mm for 100 mtr from ground level in any type of soil/strata incl hard stone and boulders etc for accomodating UPVC casing pipe of any size as directed and filling the gap with pea gravells all as directed by Engg in charge including disposal of surplus soil to a distance n.exc. 50 mtr, complete all as specified and directed.
M&L for 200 mm internal dia UPVC casing pipe conforming to IS-4985-2000 in 6m length of pressure rating 10Kgs/sq Cm with all necessary fittings including joiting and jointing materials, complete all as specified and directed.
M&L for 200 mm internal dia UPVC slotted pipe conforming to IS-4985-2000 (SCH-40) having 3mm slots in 2.44 to 3.85 mtr length with male and female end with all necessary fittings including jointing materials, complete all as specified and directed.
SEWAGE DISPOSAL (B/R PORTION)
M&L for providing, lowering, laying, aligning 300mm (OD) in postion and jointing at all level/ depth full round HDPE, DWC (double wall corrugated) pipes of SN-8 grade as per IS: 16098 (Part-2) amended upto date in trenches in complete including all material, labour section, hydraulic testing (including cost and conveyance of water to site for testing) and commissioning as per technical specification, drawing and as per circular, complete all as specified and directed.
M&L for providing, lowering, laying, aligning 450mm (OD) in postion and jointing at all level/ depth full round HDPE, DWC (double wall corrugated) pipes of SN-8 grade as per IS: 16098 (Part-2) amended upto date in trenches in complete including all material, labour section, hydraulic testing (including cost and conveyance of water to site for testing) and commissioning as per technical specification, drawing and as per circular, complete all as specified and directed.
M&L for factory made RCC cover with cover frame comprising of 75 mm thick cover, area of each cover slab exc 1.00 sqm but & not exc 2.00 sqm including provision of hot dip galvanized lifting hook for lifting overall cover with suitable size angle iron frame, RCC cover of M-30 or higher grade concrete by vibro compression process, medium duty, confirming to IS-12592 including fixing on manhole, complete all as specified and as directed.
SEWAGE DISPOSAL (E/M PORTION)
S&F PVC insulated sheathed flexible black copper cable of 4 Sqmm 4 Core, 1100 volts grade fixed to wall/ceiling, complete all as specified and directed.
Supply, installation, testing and commssioning of Non clog submersible pump, electric driven of discharge capcity 200 lpm @ 15 Mtr head, 415 V, 3 phase, 50 Hz with raising outlet 100mm, in existing sewage sump including fittings and specials, jointing and jointing material, complete all as specified and directed.
Supply, installation, testing and commssioning of control panel indoor type, floor/wall mounted, dust and vermin proof, fabricated from 1.6mm to 2mm CRCA sheet finished with Powder Coating, CPRI approved suitable for controlling sewage pumps (for Srl item No. 40 above) 2 Nos (T/P) with standby operation (1W + 1S) including connection with NO/NC Float switches, cable connection panel to pumps, RYB phase indicators, starters, pump 'ON' indicators, O/L Trip, moisture sensor, start/stop push buttons, relays, incoming & outgoing MCBs, internal connecting cables, push buttons, timer, Ammeter, voltmeter, moisture sensor, supply failure indicators, glands etc., complete all as specified and directed.
Supply and laying Ductile iron pipe 100mm bore of class K-9 with spigot and socket ends suitable for tyton jointing (push on rubber gasket joint) with cement mortar lining inside and bituminous coating outside, complete as per IS:8329, laid in trenches, testing after completion, complete all as specified & directed.
M&L for road cutting of average size 0.30m x 0.60 m for laying of MS pipe, including excavation, returning filling in, spreading, levelling well ramming in layers, soling with broken boulders/stones, WBM 7.5 cm thick coarse aggregate received from dismantling the existing road, premix capeting 25mm thick using ready mix patch repair work, complete all as specified & directed.
Description of Work / Item(s)
Amount
Comphrensive Maintenance of STP during 1st year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Comphrensive Maintenance of STP during 2nd year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Comphrensive Maintenance of STP during 3rd year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Comphrensive Maintenance/ Special repairs (if required) of STP during 4th year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Comphrensive Maintenance of STP during 5th year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Comphrensive Maintenance of STP during 6th year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Comphrensive Maintenance of STP during 7th year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Comphrensive Maintenance of STP during 8th year (after defect liability period of two years) (Repair of Pumps, Motors, Compressor Units etc. alongwith cleaning of Lifting well ,screen chamber, equalizer & fliters etc post compeltion of defect liability period, complete all as specified and directed. EQUIPMENTS TO BE MAINTAINED :- (i) Bar screen chamber (ii) MBBR reactor (iii) Air blower (iv) Tube settler (v) Filter feed Pump (vi) Filteration system (vii) Feed pump and raw water sewage pump (viii) Inter connecting pipes (ix) Chlorine contact tank/ hypo Dosing tank (x) Valves (xi) Sludge drying bed (xii) Electrical system and DB/ panel (xiii) Oil and grease trap (xiv) Raw water collection sump (xv) Installed machinary for treated water supply (xvi) Treated water tank installed with STP (xvii) Mixing of chemical as reqd (xviii) Sewage well with pump.(xviii) DG Set of Capacity 82.5 KVA - 01 No
Notes for Srl item No.1 to 08 :- (i) All consumable such as Sodium Hypochlorite and any other chemical required, compressure oil, grease etc required for operation of plant shall be provided by contractor at his own cost as per the manufacturers instructions and direction of GE during the period of Comprehensive Maintenance. Cost of the same shall be deemed included in the unit rates quoted by contractor against Srl item No.01 (STP) of Sch 'A' Section-XI (BOQ-II) for 1st and 2nd year i.e. during Defect Liability Period and for IIIrd year onwards upto 10th year in this schedule. The contractor, if found failed to provide any one of the chemical mentioned above required, shall be penalised @ Rs.500/- per day maximum upto 5% of the quoted rate for M&O for a particular year. (ii) If any loss or damage takes place to the equipment, machinery, tools, stores, fitting and fixtures etc or any other equipment installed in the pump house premises during the contract period, the same shall be made good/borne by the contractor. (iii) Any type of material/ chemical/ equipment or any other product required for smooth functioning of STP shall completely be borne by the contractor and no extra of any kind shall be paid in this regard.
M/s JAIMAA ASSOCIATES (BID ID -3217815)
RAVINDRA BROTHERS (BID ID -3217761)
M/s JAIMAA ASSOCIATES (BID ID -3217815)
RAVINDRA BROTHERS (BID ID -3217761)
M/s JAIMAA ASSOCIATES (BID ID -3217815)
RAVINDRA BROTHERS (BID ID -3217761)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tenderdocument.rar
Tender Documents • 3.61 MB
BOQ.xls
BOQ • 0.95 MB
Tenderdocument_2.rar
Tender Documents • 3.74 MB
Tenderdocument_3.rar
Tender Documents • 30.87 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .