Tender Value
₹44.5 L
EMD Value
₹88,960
Closing Date
24 May 2022, 2:00 pmClosed
EXECUTIVE ENGINEER STD GANDERBAL
OFFICE OF THE EXECUTIVE ENGINEER STD GANDERBAL
11kV INDOOR SWITCHGEAR and Miscellaneous equipments of 33/ 11kV Sub stations for Receiving Station Shahgund Under Capex BudgetStation Shahgund Under Capex Budget
2022_PDD_168182_1
STDGBL 04 OF 2022-23 DATED 30-04-2022
Open Tender
Electrical Works
Item Rate
30 days
SHAHGUND HAJIN
Please refer Tender documents.
10 documents required · 10 mandatory
₹1,000
Yes
Executive Engineer STD Ganderbal
₹88,960
Yes
1 Jun 2022
30 Apr 2022
25 May 2022
30 Apr 2022
24 May 2022
30 Apr 2022
30 Apr 2022 - 24 May 2022
Amount
11kV Indoor Switchgear & Miscellaneous equipments of 33/ 11kV Sub-stations for Receiving Station Shahgund
Supply, installation, Testing & Commisioning of 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (For 6.3 MVA (1+4)).
Supply, installation, Testing & Commisioning of 100 kVA,11/0.433KV, 3-phase Distribution Transformers with Bimetallic Terminal Connectors Energy Level-2, (Aluminium wound)
Providing & Fixing of 11kV, Gapless Surge Arrestor,9 KV ,10 KA ,LA with Polymer housing, Stn. Type.
Providing and laying of 11 kV 3- Core XLPE 400 mm² armoured, FRLS
Providing and laying of 11 kV 3- Core XLPE 240 mm² armoured, FRLS
Providing and laying of 11 kV 3- Core XLPE 120 mm² armoured, FRLS
Providing & Fixing of 11 kV Indoor Heat Shrinkable Cable Termination Kits incoming Cable 400mm².
Providing & Fixing of 11 kV Outdoor Heat Shrinkable Cable Termination Kits incoming Cable 400mm².
Providing & Fixing of 11 kV Indoor Heat Shrinkable Cable Termination Kits for Outgoing Cable 240 mm².
Providing & Fixing of 11 kV Outdoor Heat Shrinkable Cable Termination Kits for Outgoing Cable 240 mm².
Providing & Fixing of 11 kV Indoor Heat Shrinkable Cable Termination Kits incoming Cable 120mm².
Providing & Fixing of 11 kV Outdoor Heat Shrinkable Cable Termination Kits incoming Cable 120mm².
Providing & Fixing of 11 kV Isolator, double break,3-pole, 600Amp, horizontal mounting Type, with Earth Switch.
Providing & Fixing of 9 Mtr. Long Pole(ST-410 SP33)
Providing & Fixing of 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp
Providing & Fixing of MCCB ‐ 200 Amps , 36KA, 4P
Providing & Fixing of a). Battery Bank 30 V,100 AH , of 15 No. cells of 2 V each, sealed maintenance free VRLA type,High impact Polyprophelene copolymer container,flame retardant. b). 30V,100 AH , Float-Cum-Boost Charger With Full wave rectification for 220 V, 1Phase, 50 HZ AC Input Supply .
Providing & Fixing of Distribution Panel (30 V, DC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43 for 2 No battery incoming supply with 2 No 63 Amps DP MCBs for incoming supply Double busbar of adequate size, 12 No DP DC MCB (0-32A) including indication lamps and cables and other accessories
Providing & Fixing of Distribution Panel (415 V, AC) made of CRCA thickness not less than 2mm. Powder Coated, degree of protection IP43. 200 Amps Switch Fuse disconnector for incoming supply and 5 No TPN MCB's (16-125 Amps ) and 5 No DP MCBs (0-32A), rectangular busbar suitable for 200 Amps continuous Supply including indication lamps and cables and other accessories
Providing & Fixing of Fire Extingiusher Co₂ Type of 4.5 kg capacity for control room
Providing & Fixing of 3 Sand Bucket Fire Extingiusher
Providing & Fixing of Servo transformer oil immersed 7.5 KVA single phase
Providing and laying of Cement bottoming 1:2:4 mix as per REC standards 0.5cum per pole
Supply and installation of 11kV Polymeric composite Disc Insulator 12kV,min failing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Supply and installation of 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance 320mm
Providing and Fixing of Galvanised iron of different sorts
Providing and Fixing of Earthing of 100KVA substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 75 mm x10 mm & 50 mm x 6 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover.
Providing and Fixing of Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 3 mtr long through GI strip (25*3 mm)
Providing of Helmet
Providing of Rubber Gloves for 33 kV level
Providing of Rubber Gloves for 11kV level
Providing of Safety Belt
Providing of Safety Shoes
Providing of TELECOMMUNICATION FACILITIES
Providing of Earthing rod (set of 3 rods)
Providing of HV Detectors all voltages
Providing of Alumunium Ladder 2*20 ' , 3 mm Thick (Double Ladder)
Providing of Rubber Mat 1mx2m 19mm thick
BEE EMM TRADERS
BATKALOO ENTERPRISES
M/S S F ENTERPRISES
KAPH TECH CONSULTANCY (P) Ltd.
SRP Powertech Solutions LLP
stage.html
html • 0.04 MB
tech_bid_open.pdf
PDF • 0.42 MB
tech_eval.pdf
PDF • 0.42 MB
fin_bid_open.pdf
PDF • 0.64 MB
boq_comp_chart.xlsx
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .