Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.1 LAccepted-AOC 23 6 C LAL VIHAR EAST END BAMRAULI PRAYAGRAJ 211012 U P | PRAYAGRAJ | UTTAR PRADESH | 211012 | L1 | Accepted-AOC after all being lowest bid considered competitive and reasonable | |
| 2 | L2₹23.6 L+₹3.4 L (16.9%)Rejected-AOC | L2 | Rejected-AOC Not Lowest | |
| 3 | L3₹23.9 L+₹3.6 L (17.9%)Rejected-AOC HIG 40 TYPE B DEV PRAYAGAM ADA COLONY JHALWA PRAYAGRAJ U P 211015 | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211015 | L3 | Rejected-AOC Not Lowest | |
| 4 | L4₹25.1 L+₹4.9 L (24.2%)Rejected-AOC 1 1 AZAD SQUARE SOUTH MALAKA ALLAHABAD PRAYAGRAJ UP PIN 211 003 | PRAYAGRAJ | UTTAR PRADESH | 211003 | L4 | Rejected-AOC Not Lowest | |
| 5 | L5₹26.1 L+₹5.8 L (28.9%)Rejected-AOC 86 MAHEWA EAST NAINI PRAYAGRAJ U P | PRAYAGRAJ | PRAYAGRAJ | UTTAR PRADESH | 211008 | L5 | Rejected-AOC Not Lowest |
Tender Value
₹33 L
EMD Value
₹66,000
Closing Date
27 Jul 2022, 6:00 pmClosed
CWE (AF) BAMRAULI
HQ CWE (AF) BAMRAULI 211012
SPECIAL REPAIR TO ROOF TREATMENT AND ALLIED WORKS SERVICES OF POWER HOUSE BUILDING AT 820 SU AT AF STATION BAMRAULI
2022_MES_528043_2
87195/C/E8
Open Tender
Civil Works
Item Rate
182 days
Bamrauli
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) Bamrauli
₹66,000
Yes
18 Oct 2022
28 Jun 2022
3 Aug 2022
28 Jun 2022
27 Jul 2022
2 Jul 2022
Amount
Excavating in trenches, not exceeding 1.5 metre wide for wall foundation etc or for manholes etc not exceeding 10 Sqm area on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each layer in soft/loose soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified and directed.
Providing, plain cement concrete 1:4:8 type D2, (40mm graded crushed store aggregate) as in sub base flooring /foundation filling / mass concrete complete all as specified and directed.
Providing Plain, cement concrete 1:2:4, type B1 (using 20mm graded crushed store aggregate) in copings, and the like including weathering, slightly rounded or chamered angles and throating, including necessary form work complete all as specified and directed.
Providing reinforced, cement concrete 1:2:4, type B1 (using 20mm graded crushed store aggregate) (nominal mix) as in chajjas, and the like complete all as specified and directed.
Material and labour extra for forming fair finished drain on channel 30cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc (Inner girth only to be measured for payment).
Supply only integral water proofing compound complete all as specified and directed.
Material and labour brick work using sub class 'B' bricks (old size bricks) built in cement and sand mortar (1:6) straight or curved on plan exceeding 6 metre mean radius complete all as specified and directed.
Material and labour Brick work with sub-class 'B' bricks, straight or curved on plan to any radius in half brick thick walls built in cement and sand mortar (1:4) complete all as specified and directed.
Taking down wooden Windows/Doors chowkats or frames exc 1.5 sqm but not exc 4 sqm each (without taking off shutters from the frames) including making good for fixing new frame. Note :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment. (ii) Quoted rate shall deem to be included cost of making good jambs portion.
Taking down wooden windows/ventilator/chowkhats or frames with shutter not exceeding 1.5 sqm each (without taking off shutters from frame) including maxing good for fixing new frame. Note :- (i) Old shutters, frame guard bars etc shall be contractor property and necessary amount as per schedule of credit shall be deducted from the contractor payment. (ii) Quoted rate shall deem to be included cost of making good jambs portion for fixing new frame.
Material and labour mild steel TMT bars 10 mm dia, and over cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking, ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Material and labour mild steel framed work such as grills, grating etc with ends of bars shoulded, framed guard bars and similar work conforming to Fe-290 Gde E-165 fixed to frame with screws complete all as specified and directed.
Material and labour mild steel Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment conforming to Fe-410 Gde E-250 quality B complete all as specified and directed.
Material and labour cleaning the roof surface (Padding) for dust / dirt and provide roof treatment with reinforced elastomeric liquid waterproofing membrane of 400-micron thickness (Each layer of 100 micron, another layer shall be laid only after complete dried of Ist layer) having SRI of 130, tested as per ASTM E 1980 (with Solar Reflectance and Thermal remittance tested as per ASTM C 1549 and ASTM C 1371 respectively). The coating should have water absorption less than 1% as per IS : 101 (P-7/Sec-1) 1989 with the ability to resist heat upto 1200 C as per IS : 101 (P-7/Sec-3) 1990 having VOC less than 1g/ltr as per ASTM D 3960 and should have excellent resistance to transmission of ponder water up to 3.5 bars of pressure for 7-days. It should also be resistant to Ammonia solution, Sodium nitrate, Sodium hydroxide along with water and soap solution as per IS : 101 (P-7/Sec-2) 1990. The waterproofing membrane will be laminated with 25-40 micron thick transparent Nano modified composite cross linking polymeric coating with a minimum of 40% solid content as per IS : 101 (P-8/Sec 6) 1993 and also should pass impact test as per IS : 101 (P/5/Sec-3) 1988 along with having dust and water repellent and anti grafting property passing scratch hardness test of 500 g as per IS : 101 (P//Sec-2) 1988. The polymeric coating should have a self cleaning and easy to clean property with excellent weather stability and DPR (Dirt pickup ratio). Surface preparation includes pressure wash cleaning to remove all dust, fungus, etc. with pressure washer after repairing the existing roof having old bitumen membrane by filling cracks, potholes, holes with waterproofing compound having compressive strength as per IS-4031 part-6-1988 & permeability of water as per IS 2645-2003. The work will be done under the supervision of the Engineer-in-Charge by Graco airless machine and OEM should be an IGBC (Indian Green Building Council) member & GRIHA Council Certified. The coating thickness and the methodology of application shall strictly be as per the manufacture’s specifications and as approved by the Engineer-in-Charge. The manufacturer shall give a guarantee for the performance and durability for 10-years. Make : Dr. Fixit, Pildlite, Sika, M/S Starsshield Technoloty Pvt. Ltd.).
Material and labour for cutting chases, pinning in making good to facings in concrete not exceeding 75 mm wide and 65 mm depth for tubing in water proofing felt where required and pointing in cement mortar 1:3 and finished in brick wall or concrete surfaces complete all as specified and directed.
Material and labour 25 mm thick plain cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as a levelling course over a coat of cement slurry as specified in MES SSR Part I complete all as specified and directed. Note :- (i) Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I.
Material and labour 75 mm thick plain cement concrete 1:3:6 type C-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed. Note :- (i) Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I.
Material and labour 100 mm thick plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed. Note :- (i) Quoted rate shall deem to be included cost of cement slurry as specified in Para 13.32.7 of MES SSR Part I.
Material and labour roughening surfaces of old concrete floor by picking, swipping, clean and washing down with water to remove dust etc complete all as specified and directed.
Material and labour 450mmX350mm X 7-8 mm thick glazed ceramic coloured tiles in vertical surfaces such as skirting, dado, etc set & jointed in neat cement slurry and pointed in white or colured cement to match over & including 10 mm thick backing coat in cement and sand mortar (1:4) complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of backing coat.
Supply and fix non skid coloured ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.11 sqmm and not exceeding 0.18 sqmm in floor, set & jointed in neat cement slurry and pointed in white or coloured cement to match over joint free and including 15mm thick screed bed in cement and sand mortar (1:6) complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of screed bed.
Supply and fix cment concrete chequered tiles of size 20 cm x 20 cm x 25 mm thick including 20 mm thick screed bed in cement and sand mortar (1:6) set and jointed in neat cement slurry and pointed with colour cement to match complete all as specified and directed. Note :- Quoted rate shall deem to be included cost of screed bed.
Material and labour 15mm thick rendering in cement and sand mortar (1:4) on brick masonary surfaces finished even and fair without using extra cement mixed with WPC at the rate of three percent by weight of cement omplete all as specified and directed.. Note :- Water proofing compound shall be measured and paid seperatly as supply only rate.
Material and labour 15mm thick rendering in cement and sand mortar (1:4) on fair faces of brick work / concrete surfaces finished even and fair complete all as specified and directed.
Material and labour 15mm thick rendering in cement and sand mortar (1:6) on fair faces of brick work / concrete surfaces finished even and fair complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc and prepare to receive new plaster complete all as specified and directed
Material and labour complete removal of existing treatment on walls surfaces and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Material and labour preparing new plastered surfaces of wall and applying two coat of cement base paint over a coat of primer complete all as specified and directed.
Material and labour preparing new plastered surfaces of wall and applying two coat of oil bound distemper on wall surfaces over a coat of primer complete all as specified and directed.
Material and labour for preparation of old painted surfaces of wall by washing, rubbing down and applying one coats of oil bound distemper on wall surfaces complete all as specified and directed.
Material and labour for preparation of old surfaces by washing, rubbing down and applying one coats of white wash on ceiling surfaces complete all as specified and directed.
Material and labour preparing new or previously untreated steel surfaces of any description not otherwise described over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Reinforced cement concrete pipe 150 mm bore NP-3 laid in trenches and jointed in cement sand mortar (1:1) including collar complete.
Taking down carefully existing aluminium/copper batten concealed point, wiring for light/fan/socket/bell or power point including. All fittings i.e. switch, sockets, ceiling rose, regulators, batten holders, etc. Complete and making good disturbed surfaces of wall/floor to match with the surroundings of wall/ceiling/floor etc including taking down old light fittings. Note :- (i) Contractors quoted rate of this item deemed inclusive of unscrewing of the serviceable fitting and fixture as directed and deposited in MES store yard of GE (AF) Bamrauli. Receipt shall be obtained before claiming the payment of new fittings. (ii) Decision of GE shall be final and binding in respect of serviceability of fittings/fixture. (iii) Old unserviceable wiring fittings, fixture, etc other than light fittings shall be contractor's property and necessary amount as per schedule of credit from contractor due payment. (iv) Quoted rate shall be deemed to include the cost of cutting chasses for taking out concealed conduit and nitch for terminal box.
Material and labour point wiring complete with 1.5 Sq mm, single core PVC insulated PVC unsheathed multi-stranded copper conductor FRLS cable 1100 volts grade laid/drawn through and including rigid PVC conduit pipe (minimum 20 mm external dia) with necessary conduit fittings / accessories fixed concealed in walls/ceiling by means of PVC sleeve/dash fastener with cadmium plated iron screws all as per ISI including sunk type pressed steel terminal boxes for mounting, modular fittings like switches, sockets, fan regulator etc with base cover plate, grid plate etc concealed in walls etc including 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as continuous earth wire to common earth and connecting to earth dolly of one light / fan / bell point controlled by one way switch complete all as specified and directed.
Material and labour point wiring complete with 1.5 Sq mm, single core PVC insulated PVC unsheathed multi-stranded copper conductor FRLS cable 1100 volts grade laid/drawn through and including rigid PVC conduit pipe (minimum 20 mm external dia) with necessary conduit fittings / accessories fixed concealed in walls/ceiling by means of PVC sleeve/dash fastener with cadmium plated iron screws all as per ISI including sunk type pressed steel terminal boxes for mounting, modular fittings like switches, sockets, fan regulator etc with base cover plate, grid plate etc concealed in walls etc including 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as continuous earth wire to common earth and connecting to earth dolly of one 3 pin 5 amp switch socket independent board complete all as specified and directed.
Material and labour point wiring complete with 1.5 Sq mm, single core PVC insulated PVC unsheathed multi-stranded copper conductor FRLS cable 1100 volts grade laid/drawn through and including rigid PVC conduit pipe (minimum 20 mm external dia) with necessary conduit fittings / accessories fixed concealed in walls/ceiling by means of PVC sleeve/dash fastener with cadmium plated iron screws all as per ISI including sunk type pressed steel terminal boxes for mounting, modular fittings like switches, sockets, fan regulator etc with base cover plate, grid plate etc concealed in walls etc including 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as continuous earth wire to common earth and connecting to earth dolly of one 3 pin 5 amp switch socket on the same board but below the switch board of light point in the same vertical plane with other switch complete all as specified and directed.
Material and labour point wiring complete with 1.5 Sq mm, single core PVC insulated PVC unsheathed multi-stranded copper conductor FRLS cable 1100 volts grade laid/drawn through and including rigid PVC conduit pipe (minimum 20 mm external dia) with necessary conduit fittings / accessories fixed concealed in walls/ceiling by means of PVC sleeve/dash fastener with cadmium plated iron screws all as per ISI including sunk type pressed steel terminal boxes for mounting, modular fittings like switches, sockets, fan regulator etc with base cover plate, grid plate etc concealed in walls etc including 1.5 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as continuous earth wire to common earth and connecting to earth dolly of one 3 pin 5 amp switch socket out let same board complete all as specified and directed.
Material and labour point wiring complete with 4 Sq mm, single core PVC insulated PVC unsheathed multi-stranded copper conductor FRLS cable 1100 volts grade laid/drawn through and including rigid PVC conduit pipe (minimum 20 mm external dia) with necessary conduit fittings / accessories fixed concealed in walls/ceiling by means of PVC sleeve/dash fastener with cadmium plated iron screws all as per ISI including sunk type pressed steel terminal boxes for mounting, modular fittings like switches, sockets, fan regulator etc with base cover plate, grid plate etc concealed in walls etc including 4 Sq mm single core PVC insulated but unsheathed multistranded copper conductor FRLS cable as continuous earth wire to common earth and connecting to earth dolly of 16 amp switch socket outlet on independent board complete all as specified and directed.
Sypply and fix factory made sheet metal enclosures distribution boards, (protection class IP-43) double door, suitable for mounting MCBs conforming to IS : 13032, IS : 8623, BS : 5484 with 200 Amps rating copper bus bar, single pole and neutral, 12 ways, 240 volts complete all as specified and directed. Note :- MCBs shall be measured and paid for separately under respective item of this schedule.
Sypply and fix MCB, SP, 6 to 32 Amp rating, 230 volt, 10 KA, 'C' series fixed in DBs catered here in before complete all as specified and directed.
Sypply and fix MCB, Single pole and neutral, 230 volt, 40 to 63 Amp rating 10KA, C series fixed in DBs catered here in before complete all as specified and directed.
Supply and fix switch modular flush 6 A single pole one way (one module) complete all as specified and directed.
Supply and fix Ceiling rose, surface bakelite, 60 x 25, mm three terminals complete all as specified and directed.
Supply and fix Modular socket 6 / 16 Amp, 2 in 1 and 3 / 5 pin combined (two module) complete all as specified and directed.
Supply and fix Modular socket 10 Amp, 2 in 1, 2/3 Pin combined ( two module) complete all as specified and directed.
Supply and fix switch modular flush, 15/16 Amp, single pole, one way complete all as specified and directed.
Supply and fix steped type electronic fan regulator modular type and connecting up. regulator shall be of make as specified in appendix 'B' to particular specifications.
Supply, fixing and connecting in replacement LED flood l;ight fiting high way 150 watt with surge protection 4 KV in built driver and minimum 10 KV seperate IP 66 having pressure die cast aluminimum housing with heat resistent toughened glass individual LED lense complete making connection with suitable size copper conductore 3 core and suitable to sustain 440 volt for 2-4 hours complete all as specified and directed with following :- Note :- (i) LM-79 and LM-80 test report with 50000 burning hrs LED life from NABL lab shall be provided. (ii) CRI colour rendering index fixtures shall be greater than 70. (iii) System lumen efficiancy shall be 150 lumen / watt . (iv) Make - Philips, Havells, Wipro and Syska.
Supply and fix ceiling fans 1400 mm sweep white in colour of Aluminium blades(three numbers) and body,double ball bearing, down rod, .fan motor of copper, pair of canopy, shackle, assembly kit etc suitable for SP 230 to 250 volts, 50 Hz, AC supply complete all as specified and as directed. Make :- (i) Havells CAT No ES-40 5 star (energy saving fan) or equivalent model of make specified in appendix 'B' to particular specifications. (ii) Quoted rate shall be deemed to include cost of dismantling the defective ceiling fans from site and shiting the same to MES store yard of AGE E/M Bamrauli
Material and labour sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 Sqmm FRLS, 1100 Volts grade cable drawn into and including rigid non metalic PVC Conduit of size not less than 25mm dia including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and as directed. Note:- (a) Two runs of 6.0 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) Quoted rate shall deem to be included cost of cutting chasses in wall for concealling conduit and making good to match with existing finish.
Material and labour for earthing complete with galvanised steel earth plate electrode 60 x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised iron wire 4 mm dia as earth lead wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3, MES SSR Part I- with 15 mm dia medium grade GI pipe as a protection to earthing lead and 20 mm dia medium grade GI pipe for watering purpose including excavation & earth work in any type of soil, funnel, wire mesh, RCC pit with cover, cast iron frame complete and connected to earthing test point all as specified or indicated including testing on completion. Notes (i) The concrete pit shall be PCC (1:3:6) type C-1, 40mm thick precast cover slab of RCC with suitable Mild steel handle in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-I. (ii) PCC pit shall be provide at least 500 mm away from the earth pit and not on just on the eath pit and extra cost of additional length of water pipes and fittings junction etc shall be deemed to be included in the rate. (iii) Item includes the cost of 7.5 metre earth lead wire and GI pipe for protection of earth wire. Any varriation in quantity shall be adjusted.
Demolition of brick masonry quions, arches, pillars etc, but excluding ashlar fackings, dressed stonewrk and precast concrete articles. Note : (i) Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Dismantling wrought iron work in any description and any position not otherwise provided for complete all as specified and directed. Note : (i) Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for including cutting reinforcement as required to facilitate demolition all as specified and directed. Note : (i) Material retrieved under this item is contractor property and necessary amount as per schedule of credit shall be deducted from the contractor dues. (ii) Rubbish shall be removed out site MOD land.
Demolition of plain cement concrete in ground floors and pavings not exceeding 15 cm thick (below or above ground level) including cleaning the surfaces with wire brushes etc complete all as specified and directed. Note : (i) Rubbish shall be removed out site MOD land.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for cement concrete including roof padding, tarfelt or HP tiles in cement mortar bedding, or mud phuska including cleaning the surfaces with wire brushes etc complete all as specified and directed. Note : (i) Rubbish shall be removed out site MOD land.
Abhinav Builders
R K CONSTRUCTION COMPANY
Agrawal Enterprises
MOHAMMAD RIZWAN CONTRACTOR
HIMANSHU TRADERS
M/s Durgesh Kumar Mishra
M/s DKS Engineering Works
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .