| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.0 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹21.7 L+₹27,929.07 (1.31%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹21.9 L+₹54,747.47 (2.56%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹22.3 L+₹93,406.27 (4.37%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹22.6 L+₹1.2 L (5.49%)Rejected-AOC 208 L MODEL TOWN LUDHIANA | LUDHIANA | LUDHIANA | PUNJAB | L5 | Rejected-AOC Rejected |
Tender Value
₹32 L
EMD Value
₹64,000
Closing Date
17 Mar 2025, 6:00 pmClosed
Garrison Engineer(N) Mamun
Garrison Engineer(N) Mamun PIN-145001
PROVN OF TILING AND ALLIED WORKS IN BLDG NO P-21 AND PROVN OF INTERLOCKING TILES PATHWAY UNDER AGE B/R-I OF GE (N) MAMUN
2025_MES_698439_1
GE(N)/M-70/2024-25
Open Tender
Civil Works
Item Rate
Garrison Engineer(N) Mamun
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer(N) Mamun
₹64,000
20 Jun 2025
18 Feb 2025
24 Mar 2025
18 Feb 2025
17 Mar 2025
4 Mar 2025
Amount
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.5 sqm complete all as specified and directed.
Taking down chowkat or frame with shutters (without taking shutter from the frame) exceeding 1.5sqm and not exceeding 4.00 sqm each complete all as specified and directed.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each including iron mongry and removing from site, complete all as specified and directed.
Demolition of cement concrete (un-reinforced) of any description and in any position not specifically provided for, complete all as specified and as directed.
Dismantling of brick work or stone masonay built in cement mortar including all quoins, arches, pillars etc but excluding ashlar facings, dressed stonework and precast concrete articles and removal of debris/rubbish off the premises etc complete all as specified and directed.
Taking down cement plaster on brick walls or stone walls of any description etc including raking out joints, hacking for key, scrubbing down with water etc, rubbish off the premises, complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises,complete all as specified and directed.
Taking up or down steel tubing 15mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed.
Taking up or down steel tubing 20mm dia and connections, including cleaning for refixing or removal to store, complete all as specified and as directed.
Excavation over areas not exceeding 1.5m deep and getting out in any type of soil, complete all as specified and directed.
Returning filling in (soil) including spreading, levelling , watering and well ramming in layers n exc 25cm thick, complete all as specified and directed.
Removing of surplus soil to a distance n exc 50 mtr and depositing where directed at a level n exc 1.5 mtr above the starting point, complete all as specified and directed.
PCC 1:5:10 type E-2 (using 40mm graded stone aggregate) as in foundation filling and mass concrete complete all as specified.
Hard core of broken stone or boulders of guage n. exc 63mm, deposited, spread and levelled in layers n. exc 15 cm thick, watered and rammed to a true surface, complete all as specified and directed.
Brick work with fly ash (Old Size bricks) sub class 'B' bricks straight or curved on plan, exceeding 6m mean radius with old size bricks, built in cement mortar 1:4, complete all as specified and as directed.
Brick work with fly ash bricks (except bricks, using old bricks), sub class'B' bricks straight or curved on plan exc 6 mtr mean radius built in CM 1:4 complete all as specified & directed.
Brick work with fly ash bricks (Old Size bricks), sub class'B' bricks straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4 complete all as specified & directed.
Brick work with fly ash bricks (except bricks, using old bricks), sub class'B' bricks straight or curved on plan to any radius as in half brick thick walls, built in CM 1:4 complete all as specified & directed.
5mm thick rendering on concrete surface of ceiling in CM 1:3 finishing the surfaces even and smooth without using extra cement, complete all as specified and directed.
10mm thick rendering on fascia / edging / ceiling of Chajjas, roof projections etc, making the edges in line, in true shape in CM 1:3 and finishing the surface without using extra cement, complete all as specified and directed.
10mm thick rendering on fair faces of brick work or concrete surfaces in CM 1:6 finished the surface even and smooth without using extra cement, complete all as specified and directed.
15mm thick rendering cement plaster in two layers (10+5mm) on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixing with WPC finished even and smooth without using extra cement complete all as specified and directed.
20mm thick cement plaster in cement mortar 1:4 on brick or concrete surface of sunken floor finished even and smooth using WPC liquid as per manufacturer instruction @ 0.200 ltr in 50 Kg of cement, complete all as specified & directed.
15mm thick rendering on brick work or concrete surfaces in CM 1:4 mixed with water proofing compound to sunken portion with proper slope towards outside, finishing cement concrete or brick work surface even and smooth using extra cement, provide 90 micron polythene film duly applying bitumen coating @ 3.00 Kg/Sqm complete all as specified and directed. Note: WPC shall measured and paid for separately.
APP modified roof treatment over existing non-accessible RCC roof slab / chajjah / canopy / parapet walls to be executed through approved applicator of the membrane manufacturer with following specification etc complete all as specified and directed :- (a) Cleaning existing surface properly. (b) Applying oil bound bitumen primer @ 0.30 liter/Sqm manufacture by the same agency as that of APP having a density 0.87-0.89 Kg per liter at 25 degree centigrade on prepared surface. (c) Laying not less than 3mm thick APP modified water proofing membrane weighing not less than 3.60 Kg/Sqm reinforced with non woven polyster fiber weight not less than 160gsm using butane torch by torch application with 10cm side laps and 15cm end overlap of membrane. (d) Top of membrane shall be provide with solar reflective bituminous aluminum paint @ 0.1 Kg/Sqm or as prescribed by manufacture of membrane/ directed by Engr-in-charge. (e) Shifting/ removing of wire/cable/AC unit/water tank of any capacity or all other such object as per site requirement and re-fixing the same, if needed shall deemed to be included in the quoted rates. (f) Quoted rates shall deemed to be included remvoal of all loose/ packed items such as mud phuska, terrace tiles, cement screed bed,surface shall be made free from depressions before appling treatment to the roof.
Supply only liquid water proofing compound, complete all as specified and directed.
Rolled sections as in framing for doors and cladding, glazing and the like fixed with angle cleats and connecting plates, etc conforming to Fe-410-W (Gde-E-250) quality-A, complete all as specified and directed.
Factory made solid PVC door frame of size 50mmx95mm made out of 5mm wood grain printed PVC sheet reinforced with MS square tube and edges will be painted to match with printed sheet, supplying & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed.
Factory Made Solid PVC Moulded Door Shutter with wood free EPS, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick wood grain moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing, complete all as specified and as directed.
Pressed steel frames for doors/windows of size size 125x60 mm (1.25mm thick MS sheet) with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats, painted with two coats of synthetic enmal over a coat of red oxide primer complete all as specified and directed.
Pressed steel frames for doors/windows of size size 105x60 mm (1.25mm thick MS sheet) with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc, duly filling of cement concrete 1:3:6 type C-0 (using 12.50 mm graded crushed stone aggregate) to back of chowkhats, painted with two coats of synthetic enmal over a coat of red oxide primer and making good to disturbed area in same finish, complete all as specified and directed.
35mm thick, 2nd class hardwood (Sal/ Hollock) factory made, plain framed, panelled shutters (two panels) with lock rail and panel of 9mm BWP commercial ply or 12mm veneered particle board with commercial veneers on both faces, the size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, fitted to chowkats, complete all as specified and directed.
35mm thick, 2nd class hardwood (Sal/ Hollock) factory made glazed and skeleton shutters, open rebated and prepared to receive glass or gauge,etc. with sash bars, edges of framing plain, chamfered or rounded, fitted with cut & mitred beads for securing gauge sizes of members of shutters as specified in SSR Part-I Section-8, clause 8.24 (a) for door shutter supplying and fitted to chowkats, complete all as specified and directed.
18 to 20mm thick prelaminated PVC solid board with acrylic lamination not less 0.50 mm thick one side decorative choice laminate and other side balancing white laminate having weight of sheet not less than 9kg per sqm and average density ranging from 500-700 Kg/Cum fixed as in kitchen cabinet, cupboard etc fixed with screws to steel/timber frame work etc, complete all as specified and directed.
300mm size aluminium alloy, anodised, sliding door bolt with hasp and staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy (fixed in repair), complete all as specified and directed.
100mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
75mm long, mild steel cold rolled butt hinges, medium weight, complete all as specified and directed.
200mm long, aluminium, anodised, barrel tower bolts of extruded section, complete all as specified and directed.
150mm long, extruded aluminium alloy handles, fabricated type, anodised, all as specified and directed.
300mm mild steel ordinary rat tail rod pattern springs including roller and roller plate, complete all as specified and directed.
100mm long hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plateand fixed with screws, complete all as specified and directed.
25mm bore stainless steel, single curtain rod (wall thickness not less than 1mm) with fancy type/ornamental stainless steel brackets and end bulbs, fixed in repair, complete all as specified and directed.
Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples,complete all as specified and directed.
3mm thick sheet glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
3mm thick figured glass ordinary quality, and glazing with oil putty or fixed with bead/glazing pins in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed.
75mm thick PCC 1:4:8 Type D-2 (40 mm graded stone aggregate) as insub-base of floors, sub-bases, floors, pavings etc., complete all as specified and directed.
50mm thick sand cushion for interlocking paver block including watering and consiladation, complete all as specified and directed.
PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork, complete all as specified and directed.
PCC 1:2:4 type B-0 ( using 12.5mm graded crushed stone aggregate) padding as roof, surface finished even and smooth without using extra cement, complete all as specified and directed.
Vitrified tiles 10mm thick, light shade (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm in floors etc. set and jointed joint free in neat cement slurry and pointed in white or coloured cement to match and including 15 mm thick screed bed in cement mortar 1:4, complete all as specified and directed.
Non skid ceramic coloured tiles 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding (but not backing), rubish off the premises complete all as specified and directed.
Glazed ceramic coloured tiles 450mm x 350mm x 7mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles including dismantling floor, hearth or walls tilling and terrazo topping including cement mortar bedding (but not backing), rubish off the premises complete all as specified and directed.
Green/black marble work 12 to 15mm thick (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like, rendering in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble shade, complete all as specified and directed.
Round chamfering to the edges of marble slabs not exc 15 mm wide complete all as specified and directed.
80mm thick factory made machine pressed precast concrete, coloured interlocking paver block with cement and coloured pigment (topping thickness not less than 5mm thick with white cement and non-fadable epoxy coated colour pigment), any shape, size and design as approved by Engr-in charge confirming to IS 15658-2006, M-40 grade, complete all as specified and directed.
Steel water tubing, 15mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed
Refixing of old steel tubing 15mm bore and connection in old or new position (walls, ceiling or floors etc.) with new all fittings short pieces, complete all as specified and directed.
Steel water tubing, 20mm bore, galvanised, "medium grade" with all fittings and fixtures and short lengths, fixed to wall and ceiling or laid in floor, complete all as specified and directed.
Cutting chases for concealed water tubing, making good to facing where required, pointing in CM 1:3, cutting n.exc. 10cm in girth, complete all as specified and directed.
15mm bore bib tap, fancy type chromium plated cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or brass ferrule (fixed in repairs),complete all as specified and directed.
15mm bore stop valve/angel valve, chromium plated cast copper alloy, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union (fixed in repairs), complete all as specified and directed.
15mm bore concealed type stop valve/angel valve, chromium plated cast copper alloy with long shank and cup, screwed down, high pressure with crutch or butter fly handle, screwed both ends for iron pipe or union (fixed in repairs), complete all as specified and directed.
15mm bore pillar tap, fancy type, copper alloy, with capstan head, chromium plated screwed down high pressure, with or without lettered hot/cold with long screwed shanks and fly nuts screwed for iron pipe (fixed in repairs), complete all as specified and directed.
S & F in repair vitreous china, wash hand basin, white, flat back, of size 550mmx400mm with brackets including cutting for and pinning in ends of brackets, complete all as specified or erecting stand including 32mm full threaded waste coupling and 32mm PVC waste pipe, complete all as specified and directed.
S & F in repair vitreous china squatting pan water closet, orissa pattern, size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including cast iron 'P' or 'S' trap, front or back inlet and foot rests, any pattern including cement concrete bedding, complete all as specified and directed.
10 litre capacity PVC valveless, low level, synphonic action type, flushing cistern, with inlet, ball valve, float valve, handle including brackets including 32mm dia PVC flush pipe of suitable size and making necessary connections to water supply pipe line and jointing to WC, fixed in repair, complete all as specified and directed.
PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed.
Rotational moulded polythylene 500 litres capacity water storage tank (Cylindrical vertical with closed top), 3 layer hoisted and fixed in position including 20mm brass ball valve high pressure with brass rod & high density plastic ball including dismanting of existing old water tanks and removing to store, complete all as specified and directed.
Supply, fixing, jointing and testing, 20mm bore gun metal globe or gate valve with iron wheel head screwed head both for iron pipe & fixed in repair, complete all as specified and directed.
Brass chromium plated tubular towel rail, 20mm dia, D type, 60cm long between flanges (fixed in repair), complete all as specified and as directed.
125mm size brass chromium plated shower rose with or without swivel joints, any size including fixing to steel pipe of 15mm dia or union, complete all as specified and as directed.
Sheet glass shelf assembly 12cm wide consisting of 5.5mm thick glass with CP bracket guard and railing 60cm long, fixed in repair, complete all as specified and directed.
Liquid soap container of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 105gms), fixed in repair, complete all as specified and directed.
Sinks with drainage board made of 1mm thick stainless steel kitchen or laboratory with plugs, washers and wastes pipe, including pair of cantilever brackets embedded in wall with suitable size of PCC block, 1:3:6 type C-1 and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm, fixed in repairs, complete all as specified and directed.
Stainless steel kitchen plate rack of size 750 x 900mm made of 1mm thick stainless steel sheet fixed with mild steel screw, fixed in repairs, complete all as specified and directed.
100mm bore cast iron soil, waste and vent spun pipes in any length with or without ears, with cement joints, laid in floors or in trenches with complete fittings and taking down unsv pipe with fitting, complete all as specified and directed.
100mm bore cast iron soil, waste and vent spun pipes in any length with or without ears, with cement joints, fixed to wall with complete fittings and taking down unsv pipe with fitting, complete all as specified and directed.
75mm bore cast iron soil, waste and vent spun pipes in any length with or without ears, with cement joints, laid in floors or in trenches with complete fittings and taking down unsv pipe with fitting, complete all as specified and directed.
75mm bore cast iron soil, waste and vent spun pipes in any length with or without ears, with cement joints, fixed to wall with complete fittings and taking down unsv pipe with fitting, complete all as specified and directed.
50mm bore cast iron soil, waste and vent spun pipes in any length with or without ears, with cement joints, fixed to wall with complete fittings and taking down unsv pipe with fitting, complete all as specified and directed.
100mm bore cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fixed in repairs, complete all as specified and directed.
75mm dia cast iron floor trap with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4), fixed in repairs, complete all as specified and directed.
50mm dia cast iron cowls, fixed in repairs, complete all as specified and directed.
100mm dia cast iron bends, diminishing pieces or tapers, fixed in repairs, complete all as specified and directed.
100mm dia cast iron bends, diminishing pieces or tapers, fitted with oval access door, fixed in repairs, complete all as specified and directed.
75mm dia cast iron bends, diminishing pieces or tapers, fixed in repairs, complete all as specified and directed.
75mm dia cast iron bends, diminishing pieces or tapers, fitted with oval access door, fixed in repairs, complete all as specified and directed.
75mm dia cast iron branch pieces, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches, fixed in repairs, complete all as specified and directed.
100mm dia cast iron swan necks (or off- sets) upto 152mm projection, fixed in repairs, complete all as specified and directed.
Preparation of new steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Preparation of old steel surface any description over 10cm width or girth not otherwise described and applying two coats of synthetic enamel paint, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of ceiling and applying three coats of white wash,complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of wall and applying three coats of white wash,complete all as specified and directed.
Preparation of old surfaces of walls and applying two coats of white wash, complete all as specified and directed.
Preparation of old surfaces of ceiling and applying two coats of white wash, complete all as specified and directed.
Preparation of new plastered or unplastered external surfaces of wall and chajjas and applying two coats of external acrylic antifungal emulsion paint, complete all as specified and directed.
Preparation of new plastered or unplastered external surfaces of wall and chajjas and applying two coats of cement base paint over a coat of alkali-resistant priming paint, complete all as specified and directed.
Complete removal of old existing treatment of walls, chajjas, fascia etc. & applying two coats of cement base paint over a coat of alkali-resistant priming paint, complete all as specified and directed.
Preparation of new plastered or unplastered surfaces of walls and applying 2mm thick wall care putty & applying two coats of oil bound distemper over a coat of priming paint , complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying 2mm thick wall care putty & applying two coats of oil bound distemper over a coat of priming paint , complete all as specified and directed.
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including unscrewing from board fitting and fixture such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody for reuse if serviceable or for taking credit and making good disturbed surfaces of walls, floors, etc complete all as specified and directed.
Point wiring using 3x1.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor cable 1100 Volts grade (Phase, neutral and earth wire) with proper colour coding drawn through and incl PVC rigid concealed conduit medium grade (ISI Marked) of dia not less than 20mm and 1.5mm thick and connected to common earth dolly with and including 1.2mm thick GI pressed steel sunken box and 3mm thick plastic laminated sheet cover fixed with brass screws complete including cutting chases grooves for concealed wiring for light/fan/bell point controlled by one switch and making good (in CM 1:4) the surface as per existing complete all as specified and directed.
All as per Ser item No 104 here-in-before but for one light point controlled by two 2 way switch, 5/6 Amp, 240 volts.
All as per Ser item No 104 but for one 5/6 Amp socket outlet point on same board controlled by one switch.
All as per Ser item No 104 but for one 5/6 Amp socket outlet points on independent board controlled by one switch.
All as per Srl item No 104 here-in-before but for one 15/16 Amp socket point with 3x2.5 Sqmm FRLS PVC insulated unsheathed multistranded copper conductor.
Switch piano flush button single pole one way 5/6 Amp 240 volts complete all as specified and as directed.
Switch piano flush button single pole two way 5/6 Amp 240 volts complete all as specified and as directed.
Switch piano flush button single pole one way 15/16 Amp 240 volts complete all as specified and as directed.
Socket outlet 2 in 1, 3 pin, 5/6 Amps, flush type, 240 volts complete all as specified and as directed.
Socket outlet 2 in 1, 6 pin, 6/16 Amp flush type, 240 volts complete all as specified and as directed.
Bell push, flush type, 5/6 Amp AC 230 Volt etc, complete all as specified and directed.
Bell Ding Dong AC 230 Volt, single pole, complete all as specified and directed.
Stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. not less than 100W as reqd., complete all as specified and directed.
Ceiling rose 3 terminal bakelite 65mm x50mm surface type, PVC/ Polycarbonate, isolated body, complete all as specified and directed.
Lamp holder, PVC/ Polycarbonate type with back plate, straight/ angular suitable for batten fittings, complete all as specified and directed.
LED lamp, 12 watts, 230volts, retrofit, complete all as specified and directed.
Taking down carefully unsv copper/aluminium sub main wiring of any size including old broken steel/PVC conduit, removing materials to store for keeping in safe custody for taking credit complete all as specified.
Sub main wiring with two single core PVC insulated unsheathed multistranded flexible copper conductor cable of size 6 sqmm and one single core PVC insulated multistranded unsheathed flexible copper conductor cable green colour of size 6 sqmm as earth lead in & including concealed rigid medium grade PVC conduit medium grade not less than 25mm dia ISI marked with all accessories and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as required at site or directed.
Replacement of LED lights fitting, 1x20W, 4' long 230V, 6500 K, AC, intenso LXS LED batten, wall mounted, PF-0.95, CRI-80, 25000 Hrs life, aluminium housing, pe-wired internally with all accessories, driver including LED tube light and connecting up with three core flexible copper conductor cable of suitable size from ceiling rose and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed.
Replacement of LED light fitting mirror type with high out put diffuser 2 feet, 10 watt, 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed.
Replacement of 10W bulk head LED luminaire, energy efficient wall mounted, pressure die-cast aluminium housing and enclosed with polycarbonated cover with all accessories including lamp, internally prewired and connecting up with suitable size flexible copper conductor cable from ceiling rose to connector of LED fitting and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed.
1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 16 sqmm nominal cross section 2.0 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers incl taking down old unsv cable, complete all as specified and directed. Note- Earth work and protection work shall be measured and paid for separately under respective items of BOQ.
Excavation in trenches not exceeding 1.5 m wide and n.exc. 1.5 m deep for foundation of poles/stay/cable etc including getting out in any type of soil complete all as specified and directed.
Sand cushioning to cable with dry fine sand in trenches 8 cm below the cable and 15 cm above the cable after laying, complete all as specified and directed.
Bricks laid in trenches flat with width equal to length of brick for cable protection well burnt sub class 'B' laid across the cable complete all ad specified and directed.
40mm dia GI tubing, light grade with all fitting laid in trenches or fixed on wall or along pole complete for protection of electric cable/strip, complete all as specified and directed.
Replacement of MCB DB, SPN, 8 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 100 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall including cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed.
Replacement of MCB DB, TPN, 4 way sheet metal enclosures double door 230 V AC, 50 Hz AC with IP 54 and IK 09 rating having fully insulated copper busbar of rating 200 Amps, insulated neutral bar, earth bar and cable ties for cable management including polyuthrene gasket complete complete in all respect flushed in wall including cutting chases on wall for taking out old unsv DB and fixing of new DB and making good disturbed surface of wall with cement mortar 1:4 and finishes to match exisiting surface, complete all as specified and directed.
MCB, SP, AC, 240 volts 'C' series capacity of 6-32 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed.
MCB, SPN, AC, 240 volts 'C' series capacity of 32 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed.
MCB, TPN, AC, 415 volts 'C' series capacity of 40-100 Amps, 50 Hz, 10kA and making connections, complete all as specified & directed.
LED street light fitting 60 watt 230 V AC outdoor type with high pressure die-cast aluminum hosing, PC diffuser, and heat resistant complete with integrated electronic driver with high efficiency including 32mm bore GI pipe bracket mounted on wall or roof using clamps, nuts, bolts, washers, fasteners etc.complete with polycarbonated cover, IP 65/66 protection and connecting up with three core flexible copper conductor cable of suitable size, complete all as specified and directed.
Taking down carefully serviceable single phase energy meters from meter box after carefully disconnecting the electrical connections and keeping aside for refixing and dismantling old burnt/unsv meter box and removing to store for keeping in safe custody for taking credit and making good to disturbed surfaces of walls , floors etc. complete all as directed.
Sheet moulded compound (SMC) meter box fire retardant type of size not less than 600x500x150mm to enclose 04 Nos single phase electric meters with hinged type front operated door having transparent acrylic sheet and proper locking arrangement and flush mounting in wall incl refixing the serviceable electric meters dismantled under Srl Item No 42 and making electrical connections including cleaning of disturbed area and making good the disturbed surface and matching with existing specification, complete all as specified and directed.
Earthing complete in repair with galvanized steel earth plate electrode 60cm x 60cm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 mtr deep below GL with top edge of the plate not less than 1.5 mtr below normal GL and connected to earth plate surrounded by 15 cm thick packed layers of charcoal dust and common salt and connected to earth lead GI wire 4mm dia by means of bolts, nuts, check nuts and washers of galvd iron or steel and thimbles and other end of the earth wire connected to DB and protected by galvd iron or steel pipe light grade 15 mm bore and water pipe 20mm bore GI light grade with funnel and wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electrical plate No 3 of MES schedule Pt I of 2009. Note : RCC pit cover shall be pre-cast of RCC (1:2:4) type B-I , 80mm thick reinforced with XPM weighting not less than 4 KG/sqmm in lieu of CI cover.
Abrol construction co (BID ID -3264104)
dadwal engineers (BID ID -3259779)
M/S RANBIR SING AND CO (BID ID -3259294)
s k construction co (BID ID -3257037)
M/S BHOTO AND CO (BID ID -3256064)
WALIA ENTERPRISES (BID ID -3259371)
malghotra construction co (BID ID -3264975)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .