Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 CrAccepted-AOC | ₹5.2 Cr | L1 | Accepted-AOC AWARDED AS PER COMMITTEE |
| 2 | L2₹5.4 Cr+₹25.5 L (4.92%)Rejected-Finance | ₹5.4 Cr+₹25.5 L (4.92%) | L2 | Rejected-Finance REJECTED AS PER COMMITEE |
| 3 | L3₹5.8 Cr+₹64.5 L (12.5%)Rejected-Finance | ₹5.8 Cr+₹64.5 L (12.5%) | L3 | Rejected-Finance REJECTED AS PER COMMITEE |
| 4 | L4₹62.8 L−₹4.5 Cr (87.9%)Rejected-Finance HARI HAR ENCLAVE 3RD FLOOR CHRISTIAN BASTI G S ROAD GUWAHATI 781005 KAMRUP M ASSAM | KAMRUP METRO | ASSAM | 781005 | ₹62.8 L−₹4.5 Cr (87.9%) | L4 | Rejected-Finance REJECTED AS PER COMMITEE |
| 5 | Rejected-Technical | - | - | Rejected-Technical Non-responsive as per the recommendations of the Committee. |
Tender Value
₹6.0 Cr
EMD Value
₹11.9 L
Closing Date
6 Jul 2019, 2:00 pmClosed
Registrar
O/o Registrar,Cotton University, Panazar, Guwahati-01
Construction of two storied R.C.C Administrative Building covering Civil, Sanitary, Water Supply and Electrical Works
2019_CU_13140_1
CU/EC/2018/055/5199-5204 Dated 15/06/19
Open Tender
Composite Works
Item Rate
540 days
Cotton University, Panbazar, Guwahati
Please refer Tender Documents
5 documents required · 5 mandatory
₹5,000
The Registar Cotton University
₹11.9 L
Yes
O/o Registrar, Cotton University, Panbazar, Ghy-01
31 Mar 2021
17 Jun 2019
9 Jul 2019
17 Jun 2019
6 Jul 2019
17 Jun 2019
24 Jun 2019
Amount
EARTH WORK :
1.1. Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified.
(A) Up to a depth of 2.00m below the existing ground level.
(a) In ordinary soil.
(B) Extra over item No. 1.1 (A) above for each 1 m depth or part thereof veyound the initial depth of 2 m.
1.3. Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary.
(c) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
PLAIN CEMENT CONCRETE WORKS :
2.1.1. Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately).
In prop. 1:3: 6 (1 cement:3 coarse sand : 6 coarse agg. by volume (using mixture machine)
2.1.2. Plain cement concrete floor base in prop1:3:6 laid in alternate bays as specified with coarse agg. of size 13mm to 32mm including dewatering if necessary, and curing etc. complete.
(i) 100 mm thick in prop 1:3:6
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
REINFORCED CEMENT CONCRETE WORKS :
2.2.1. Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately)
I. Using Batching Plant/ RMC/ Truck mounted batching plant including Transit Mixer and Concrete Pump
(A) In substructure upto plinth level
Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level.
a) M15 grade concrete or Prop. 1:2:4
Using Admixture Plasticiser
(b) M 25 grade concrete
(B) Super-structure from plinth level upto 1st floor level.
(i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc.
(i) Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc.
(a) M 25 Grade concrete
ii) Columns, pillars, posts, struts, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing.
Using Admixture Plasticiser
(a) M 25 grade concrete
iii) Suspended floor, roof landing, shelf balcony litelsill band with using admixture plasticiser.
Using Admixture Plasticiser
(a) M 20 grade concrete 1:1.5:3
vi) Vertical and horizontal fins (thickness not more than 100mm) individually or forming box louvre, projected band and suspented floor using plasticiser.
(a) M 20 grade concrete or prop. 1 :1.5 : 3
2.2.3. Extra over item Nos. 2.2.1 (I) (B), above for each subsequent floor or part thereof above the 1st floor level.
Note : The Admixer plastiaser in the above items shall be of Chokscy / penetrone / PIDILITE.
SHUTTERING & FORM WORKS :
3.1.1. Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in:
3.1.1.1. Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc.
(I) Using 38mm thick plank.
Sides of tie beams, grade beams etc. at or below ground level.
(ii) Using 25mm thick plank.
PLYBOARD SHUTTERING (FORMWORK)
3.2.1. Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in:
3.2.1.1. Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
3.2.1.2. Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties.
(a) For depth not exceeding 1.0M.
3.2.1.3. Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like.
(a) Floors etc. upto 200mm in thickness.
3.2.1.6. Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
3.2.1.7. Vertical ties, fins, sun breaker, louvers, bands, dropwalls etc.
3.2.1.8. Staircase with sloping or stepped soffits including risers and stringers but excluding Landing.
3.2.4. Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no. 3.2.1 & 3.2.3(b).
BRICK WORK :
4.1.1. Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete.
(a) Brick on flat soiling
4.1.2. Filling sunken floor with broken jhama brick bats and sand including compacting and supplying of materials complete as specified and directed for all levels.
4.1.4. Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed.
(I) In Sub-structure upto plinth level including dewatering if necessary
(b) In proportion 1:4
A A C BLOCK :
4.4.2. Superlight Weight Autoclaved Aerated concrete Block work using Grade -I AAC block of Size 625 x 240mm of different thickness of compressive strength 40 kg / cm2 having dry desity 550 to 650 Kg /Cum confroming to IS-2185 Pt - 3 or Pt - 4 in cement mortar of prop 1 : 4 including racking out joints and curing complete as specified and directed. (protruding rod is to be provided at every 3 course interval and will be measured and paid separately)
(II) In superstructure above plinth level up to 1st floor level.
(a) For 200mm thick wall
(b) For 125mm thick wall
4.4.3. Extra for AAC block walling for each subsquent floor or part thereof above the 1st floor level.
(i) For 200mm thick wall over item No. 4.4.2. (II)(a)
(b) For 125mm thick wall over item No. 4.4.2. (b)
FLOORING & FLOOR FINISHING :
5.7.2.1.Providing VITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base of cement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department)
a) Normal range Somany/ Orient/Nitco /Varmora/VITA/ Marbito/ Make
ii) Of size 600mmx600mm and above
5.1.10. Cement plaster skirting with cement mortar in prop. 1:3 (1cement :3 coarse sand) finished with a floating coat of neat cement including rounding of junctions with floor.
(i) 15mm thick.
5.7.1.2. Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls).
a) Delux range Somany/ Orient/Nitco/Varmora Make
i) Of size 300mmx450mm and above
5.10.5. Providing polished granite slab of approved quality, size, shape and thickness not less than 18 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile Choksey/Sika/Pedelite/Rouf) /white cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of slab and as approved and directed by the Department).
(i) Normal Quality
(ii) With white cement
5.11. Providing ANTISKID tiles of approved quality size, shape not less than 8mm on floor, skirtings over a cement mortar bed 15mm thick of 1 : 3 (1 cement : 3 coarse sand) approved make fix with Fix -A - Tile (Choksey / Sika /Pedelite Rouf) / white cement complete at all level as specified and directed.
(B) VITRIFIED
iii) Executive range - 2 (Sizes 600 mm x 600mm and above)
(i) Nitco made
(c) Tuscan Series - Gres Lepato
PLASTERING WORKS :
6.2.1. 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises or rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed.
In cement mortar 1:4
6.2.2. 15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed.
A) On rough side
(b) In cement mortar 1:4
B) On fair side
(b) In cement mortar 1:4
6.2.5. Extra over item no 6.2.1 to 6.2.2 for plastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed.
6.2.6. Extra over item no 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every additional floor or part thereof including curing complete.
On single coat plaster.
6.2.7. Extra over item no 6.2.1 to 6.2.2 for exterior plastering over wall up to a height of 1st floor level above ground level including curing complete as directed.
a) On Single coat plaster
6.2.8. Extra over item no 6.2.1 to 6.2.3 for interior plastering above 1st floor level for every additional floor or part thereof including curing complete.
a) On Single coat plaster
ROOFING WORKS :
8.1.36. Providing Pre Painted Galvalume Sheet (PPGL) accessories ( Ridges / Valley / Gutter / Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
(iv) 0.60 mm thick
8.1.34. Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement
v) 0.60 mm thick
8.2.1. Grading roof for water proofing treatment with (a) Cement concrete 1:2:4 (i) 1 cement: 2 coarse sand: 4 graded stone agg. 20 mm nominal size)
WOODEN DOORS, WINDOWS AND OTHER WORKS
9.1.2. Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified.
(a). With sal wood
9.6.2. Providing and fixing 1st class timber moulded beading of size 25mm x 15mm around panel inserts of doors with countersunk wood screws including applying a coat of wood preservative on unexposed surface.
(ii) With Gamarai Wood.
None Schedule. Providing and fixing factory made fully panelled door shutters treated against termite with panel mserts of 12mm thick prelaminated particle board decorative lamination on both sides including moulded timber leading of 25mm x 15mm around the panels complete as per drawings
40mm thick with Teak wood
None Schedule. Providing and fixing centuryply flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels confirming to relevent I.S. code including stainless steel butt henges (100mm x 75mm x 3.5mm) 4 Nos with necessary wooden screws.
(a) Non decorative type and block board core one side finished with decorative lamination of Green ply and providing fitting 1st class teak wood beading of 25mm minimum depth on all edges of shutters.
30mm thick with Teak wood
(b) Non decorative type and block board core one side finished with decorative lamination of Green ply and providing fitting 1st class teak wood beading of 25mm minimum depth on all edges of shutters.
40mm thick with Teak wood
GRILL WORKS :
10.2. Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S. bars with round headed bolts and nuts or screws.
I. Plain Grill.
(c) Fixed to Brick work/P.C.C./R.C.C
UPVC WINDOWS AND VENTILATION :
12.12.2. Supplying and installing uPVC- Sliding Windows made out of Lead free green profile having "GREENLINE" mark of BIS standard uPVC multichambered sections of wall thickness 2.4mm with corners fusion welded, fully reinforced with Galvanized steel 1.5/2mm including interlock profile, glazing bead, grooving bead, brush seal, aluminum sliding track, stainless steel rollers, sealing wedge block, Espag, int handle, pop up handle, keeper, drain cap, fisher screws, packing pieces with all necessary stainlessness screws etc. complete as directed. The windows must be installed complete with all kinds of ironmongery including EPDM gaskets, bridging wedges and glass packers and with suitable water draining system. Application of silicon sealant from inside / outside of Dowcorning / GE or equivalent. With 5mm clear glass
(a) 2 Track Sliding Window without Flyscreen using uPVC section of size 58mm x 53mm x 2.4mm thick wall for frame, 37mm x 61mm x 2.4mm thick wall for glass sash having 1.5mm thick reinforecement for both frame & sash, Interlock: 43mm x 23mm (Glass Panel) (WINSTA KOMMERLING/ FINESTA/ ENCRAFT)
(i) 2 - Panel with 5mm clear float glass
(i) 3 - Panel with 5mm clear float glass
(b) Single leaf Top hung Window using Upvc section of minimum sizes 58mm x 57mm x 2.4mm thick wall for frame, 58mm x 68mm x 2.4mm thick wall for glass sash with 5mm clear float glass.
ALUMINIUM PARITION WALLS :
11.2.1. Providing, fitting and fixing anodised aluminium framed glazed doors with partition walls partly glass and partly prelaminated board with anodised aluminium frame made of 100mm x 43mm x 2mm sections of approved brand with doors style of size 81mm x 43mm x 2mm, top rails 46mm x 43mm x 2mm, lock rails 81mm x 43mm x 2mm, fitting with glazing clip, special rubber type gusket complete including hydraulic floor spring pivot aluminium door handle lock angles cleat etc. complete as directed by the department at all levels.
(i) 6mm thick glass panes and 12mm prelaminated board
18.7.2. Providing, fitting and fixing powder coated pressed steel door frame made of 1.25mm/ 1.6mm thick sheet of various sizes with necessary hinge jamb, lock jamb, head and steel base ties at the bottom of the frame. The whole frame shall be welded or rigidly fixed together by mechanical means with base ties of pressed mild steel angle of size 20x20x1.25mm thick. Frame to be filled up with 1:4:8 P.C.C. after fitting the frame with brick/ concrete works etc.complete as directed by the department for all levels. (P.C.C. to be measured and paid for seperately).
(a) 1.60mm thick sheet
(iv) Size 125mm x 60mm (Double rebate)
PAINTING WORKS :
13.4.1. Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth.
(a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
13.2.3. (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
13.3.4. Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm)
(i) Thickness = 1.5mm thick
13.6.3. Applying priming coat over new wood and wood based surfaces over 100mm in girth/width after and including preparing the surface by throughly cleaning oil, grease, dirt snd other foreign matter , sand papering and knotting.
(b) With ready mixed paint , wood primer (white).
13.6.5. Painting two coats (excluding priming coat) on new wood and wood based surface with enamel paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter sand papering and stopping.
(i) Surfaces over 100mm in width or girth.
(a) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
13.7.2. Applying primary coat over new steel and other metal surface over 100m in width or girth after preparing the surface by throughly cleaning oil,grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper.
(A) With ready mixed "red-lead/ red oxide" primer.
13.7.4. Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter.
(i) Surfaces over 100mm in width or girth.
(b) High gloss (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
19.9.1. Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
13.9.1. Finishing old / new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Berger paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
BUILDING HARDWARE :
15.2.1. Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished )
(a) Sliding door bolts
(ii) 250mm x 16mm
(b) Tower bolts
(i) 300mm x 12mm
(iii) 250mm x 12mm
(iv) 150mm x 10mm
(c ) Door handles
(i) U-type 230mm long handle stainless tube
(m) Mortice lock vertical type
( ii) 75mm (Godrej with handle (4-lever)
(t) Door stopper with rubber stopper
STEEL & IRON WORKS :
18.1.1. Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level)
a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL
(i) TMT Corrosion resistant steel (CRS) reiforcement bar
(ii)Super Ductile (SD) TMT reinforcement bars
18.3.2. Providing, fitting, hoisting and fixing of roof trusses fabricated out of combination of any two or all of the following sections (i) Square section (ii) Rectangular Hollow section of specification RSH/SHS and (iii) M.S. circular hlollow section of Grade 210 including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications.
a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
18.9.1. Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (Wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, ie fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer in - charge (For payment, only weight of Stainless steel member is to be considered. No extra payment for fixing accessories such as nuts, bolts, fasterners etc. will be considered.)
PLINTH PROTECTION WORKS :
19.1. Providing plinth protection 50mm thick to cement concrete 1 : 3 : 6 with coarse agg.of 20mm nominal size including finishing the surface with 10mm thick cement plaster in proportion 1:3 with a floting coat of neat cement finished.
WATERPROOFING WORKS :
22.3.10. Providing and applying over sunken slab etc., two coats of waterproofing slurry prepared with neat cement, water and modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/ RHEOMIX 141 by brush after proper surface preparation (surface preparation including thorough cleaning of surface to be measured and paid separately) as specified & directed by the Department complete.
PRE-CONSTRUCTION ANTI-TERMITE TREATMENT :
26.1.1. Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
(a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
26.1.2. Pre construction anti - termite treatment in the back fill in immediate contact with the foundation structure after completion, column, wall etc. to a depth of 450mm and width 300mm (when required refill in 200mm thick ayers) applying the emulsion @ 5 (five) litres per square meter towards the concrete and masonry walls so as to ensure earth in contact with the structure well treated - with chemical (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
(a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
26.1.3. Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
(a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
26.1.5. Pre construction anti - termite treatment by applying the soil along the external perimeter of the building (after construction completed) to a distance close to the plinth wall as specified and as directed by the deptt. up to a depth of 300mm making rod holes along the line @ 150mm apart to a depth of 300mm and applying emulsion @ 4.5 litres per running meter ensure moistening of the soil with emulsion (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete.
(a) With aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
FLASE CEILING :
7.2.1. Supplying, fitting, fixing and painting where necessary (one coat primer and two coats of paint) M/F Suspended Ceiling which includes G.I. perimeter channels of size 0.55mm thick (having one flange of 20mm and another flange of 30mm and a web of 27mm) along with perimeter of ceiling, screw fixed to brick wall/ partition with the help of nylon sleeves and screws, at 610mm c/c. Then suspending G.I. intermediate channels of size 45mm (0.9mm thick with two equal flanges of 15mm each) from the soffit at 1220mm c/c with ceiling angle of width 25mmx10mmx0.55mm thick fixed to soffit with G.I.cleat and steel expansion fasteners. Ceiling section of 0.55mm thickness having knurled web of 51.5mm and two equal flanges of 26mm each with lips of 10.5mm are then fixed to the intermediate channel with the help of connecting clip and in direction perpendicular to the intermediate channel at 457mm c/c, 9.5mm/ 12.5mm tapered edge Gypboard (conforming to IS:2095-1982) is then screw fixed to ceiling section with
25mm long drywall screws at 230mm c/c. Screw fixing is done mechanically either with screw driver or drilling machine with suitable attachment. Finally, the boards are to be jointed and finished so as to have a flush look which includes filling and finishing the tapered and square edges of the boards with jointing compound, joint paper tape and two coats of drywall topcoat suitable for Gypboard complete at all levels as specified and directed. (For light fittings, providing opening for doors, window, ventilators etc, cut out made with frame of perimeter channel supported suitably to be measured and paid separately where necessary).
9.5MM THICK
31.14.6. Providing & fixing Armstrong Mineral fibre Acoustical suspended ceiling system with fine fissured / classic lite ( bev. tegular) edge tiles with armstrong XL 15mm exposed / silhouette grid (600x600x16)mm
31.14.8. Providing & fixing Armstrong Mineral fibre Acoustical suspended ceiling system with ANF (bev. Tegular) edge tiles with armstrong XL 15MM exposed / silhouette grid (600x600x16)mm
31.1. Supplying, fitting and fixing SoundSoak NSS Cord (FSS Cord) wrapped acoustical wall panel system of Anutone Acoustics Ltd. Including all fixtures and fittings.
20mm thick
7.12.2. Providing and fixing double skinned partitions using G.I. sections High Pressure Steam Cured non asbestos Fibre Cement wall board conforming to IS 14862-2000 , fixed on frame work using 25mm fully threaded self embedding type Fibre Cement Screws @300mm c/c on either side of Steel G.I. 51mm studs (0.55mm thick having one flange of 40mm and another flange of 42mm ) placed at 600mm c/c in 51mm floor and ceiling channel (0.55mm thick having equal flange of 32mm G.I. steel) with joints staggered to avoid through joints, all complete as per the drawing & direction of Engineer-in -Charge. The boards may be finished so as to have a uniform gap/groove or Flush finish.The flush finish should be done with Elasto prefab joint sealant. Everest Internal Jointing Compound and paper tape as per the procedure laid down by the company. Alternatively, the uniform gap/groove may be covered with decorative molding or may be finished with Jointing filler. Finally, if specified the boards to be painted with 2 coats of acrylic emulsion paint of approved
shade/make, over a coat of cement primer before installing it on the grid.
B. For Wet Area
ii) Using 12 mm thick FC Wall board of Everest make or equivalent
PAVERS :
Providing SUN ROCK HIGH CTS / DEVI paver bolck / tiles of concrete grade M30 or avobe of approved quality size shape of specified thickness over a leveling bedding layer of 30mm compacted sand over a base course of WBM or PCC (Base course to be paid separatly) including cuting where necessary finished with spreading sweeping jointing sand and compacting the pavers using vibrating compactor as specified and directed.
SUN ROCK HIGH CTS / Devi Tiles (Pavers)
(a) 60mm thick
SANITARY & WATER SUPPLY WORKS :
1.1. Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately)
1.1.1. Indian type W.C Orissa pattern of size 580 x 440 mm
b) Coloured
ii) Hindware make
1.2. Providing fitting and fixing vitreous china pedestal type water closet (European type W.C pan 400mm high ) with seat and lead ,CP brass hinges and rubber buffers , CI/MS brackets , 40 mm dia flush band with fittings including painting of fittings and brackets, required. (Flushing Cistern to be paid separately)
B) Hindware make
b) White
(i) Water closet UNIVERSAL "S (Cat.No.20012) (inclusive of seat cover)
(ii) Wall mounted Closet Cornice (inclusive of seat cover and fittings)
1.5. Supplying, fiting and fixing PVC flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
ii) Hindware make
b) Coloured
(i) Sleek + PVC cistern
1.6. Supplying, fiting and fixing concealed cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately)
(B) Hindware Make
(i) Concealed Cistern 83mm with Prime flush plate 83mm
P1.7. roviding fitting and fixing vitreous china flat back type lipped front urinal basin of with automatic flushing cistern with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required.
B) Hindware make
a) White
(i) AQUAFREE URINAL (Cat. No.60017)
1.13. Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately)
1.13.1. PEDESTAL BASIN (with pedestal)
(b) Coloured
(i) CEDER 570 x 440 (Cat. No.91049 /91115)
1.13.5. Counter Top Basin
(B) Hindware Make
(iii) Round Starlet 490 dia (Cat. No.10052)
1.15. Providing fitting & fixing stainless steel kitchen sink of Parryware make with CI/MS brackets, C.P. brass chain with rubber plug, PVC waste pipe etc. complete including painting the fittings ,cutting &making good the walls wherever required. (Sink cock, stop cocks, waste coupling are to be paid separately
(A) Parryware Make
(i) Single Bowl Drain Board (400 x 200) Flat Edge- Glossy (Cat.No.C8545)
1.19. Providing fitting and fixing Decorative Mirror complete as directed and specified.
(A) Parryware Make
(b) Size 600mm x 450mm
1.23. Providing, fitting and fixing Liquid soap dispenser and liquid soap container complete as directed and specified.
(i) Jaquar Make
(a) Continental (Cat.No.ACN-1137N) (with mettalic bottle)
1.31. Providing, fitting and fixing Chrome Plated TOILET PAPER holder complete as directed and specified.
(i) Jaquar Make
(ii) Continental toilet paper holder with flap (Cat.No. ACN-1153N)
1.27. Providing, fitting and fixing Chrome Plated robe hook complete as directed and specified.
(i) Kubix (Cat.No.AKB-35791)
1.20. Providing fitting and fixing Glass Shelf complete as directed and specified.
Jaquar Make
(i) Kubix 600mm long (Cat. No.AKB-35771)
None schedule. Providing hand sower (Health faucet) of Jacquar Allied with 1 metre long Easy Flex Tube in chrome finish and wall hook with N.R.V. (Back Flow Preventor) (CAT NO. ALDCHR.579)
1.24. Providing, fitting and fixing CP towel rail complete as directed and specified.
(a) Jaquar Make
(ii) Continental 600mm (Cat.No. ACN-1111N)
1.33. Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified.
(a) Jaquar Make
(ii) Bottle trap (with internal partition) 32mm size with 300mm long wall connection pipe (Cat.No. ALD-769B)
1.37.1. Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified.
a) In exposed surfaces or in trenches.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
1.37.3. Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
1.37.4. Supplying fiting and fixing 45 degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
1.37.5. Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
1.37.6. Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
1.37.7. Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified.
a) In exposed surfaces or in trenches.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages.
(i) 160mm dia.
(ii) 110mm dia.
(iii) 75mm dia.
1.39. Providing fitting and fixing PVC cowel of ISI make complete as directed and specified.
(ii) 110mm dia. PVC cowel of ISI make
1.42. C.P. Grating
(ii) 110mm dia.
1.51. Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
1.52. Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
3.1.2. Supplying fitting and fixing approved uPVC Pipes of different sizes, with all necessary 'R' brand or similar approved P.V.C. Fittings such as bend, tee, elbow, reducer, nipple, plug, long screw fitting, clamps etc. complete at all levels including below G.L. as directed and specified.
(A) Exposed or in trenches
SUPREME/ PRINCE/ SFMC BRAND or other equvalent approved brand (High presure pipe Sch-40)
a) 50 mm dia
b) 40 mm dia
c) 32 mm dia (Medium)
d) 25 mm dia (Medium)
(B) Concealed by chieselling or breaking brick wall/ C.C. wall/ R.C.C. wall and making good to the damaged structure.
SUPREME/ PRINCE / SFMC / FUSION BAND or other equvalent approved brand (High presure pipe Sch-40)
d) 25 mm dia
e) 20mm dia
f) 15 mm dia
3.2.1. Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately)
(i) Jaquare make
(a) Continental /Clarion
(ii) Bibcock long thread
3.3.2. Supplying fitting and fixing chrome plated (C.P.) stop-cock of approved brand and size as mentioned below as directed and specified.(G.I. & C.P pipes will be measured and paid separately)
(i) Jaquare make
(ii)15mm dia( Angular stop cock )
(v) 15mm dia, (Concealed stop cock extra heavy with adjustable wall flange )
Non Shedule. Supplying and fitting fixing C.P. pillar cock of 15mm dia.
(II) Jaquare make
(a) Continental Quarter turn ELR - 5015
3.17.1. Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed.
b) 40 mm dia.
c) 25 mm dia.
5.4.2. Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Polycon / Patton make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes
(II) 1500 litre capacity
(a) Sintex make
ELECTRICAL WORKS
(A) INTERNAL ELECTRIFICATION :
1/2.11. Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete
2.11.1 a) Short Point upto 3.00 metre length.
2.11.2 b) Medium Point upto 6.00 metre length.
2.11.3 c) Long Point upto 10.00 metre length.
2.12 Wiring to a 5 pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete.
2.12.1 SP upto 3.00 metre length.
2.12.2 MP upto 6.00 metre length.
212.3 LP upto 10.00 metre length.
3/2.13 Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including and fixing 5/6 pin 16 Amps flush type socket outlets and 16 Amps flush type switch ( Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.)
2.13.1 SP upto 3.00 metre length..
2.13.12 MP upto 6.00 metre length.
2.13.3 LP upto 10.00 metre length.
2.6.2 Wiring for circuit wiring with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
With 3 x 1.5 sq. mm. cable in 20 mm dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
5/2.7. Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system.
2.7.1. With 2x2.5 sqmm+ earth continuity with1x2.5 sqmm PVC insulated unsheathed single core copper conductor cable in 19mm diarigid PVC conduit pipes.
2.7.2. With 2x4 sqmm+ earth continuity with1x2.5 sqmm PVC insulated unsheathed single core copper conductor cable in 19mm diarigid PVC conduit pipes.
2.7.3. With 2x6 sqmm+ earth continuity with1x4 sqmm PVC insulated unsheathed single core copper conductor cable in 19mm diarigid PVC conduit pipes.
2.9 Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/ recessed PVC 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system.
2.9.3 With 4x 6 sq. mm. + earth continuity with 2x4 sq. mm. cable in 32 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.9.4 With 4 x 10 sq. mm. + earth continuity with 2x6 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
2.9.5 With 4 x 16 sq. mm. + earth continuity with 2x10 sq. mm. cable in 40 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
SB8.4 Supplying including installation of socket outlet 10/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
SB8.5 Supplying including installation of socket outlet 6/10/13 Amps INTERNATIONAL SOCKET , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including
SB8.7 Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
SB8.8 Supplying with fitting fixing of 6/10 amp one way modular clip in switch, MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary
SB8.13 Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) in surface/ recessed system complete as per direction of department.
SB8.13.3 3 module
SB8.13.5 6 module
SB8.13.7 12 module
SB8.14 Supplying including fitting fixing of following MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) front plate of suitable colour as per direction of department.
SB8.14.3 3 module
SB8.14.5 6 module
SB8.14.7 12 module
SB8.18 Supplying with fitting fixing of blank plate single in modular switch system , MODEL RANGE LEGRAND (ARTEOR), ANCHOR (AVE), MK (BLENZE), SCHNEIDER (ZENSELO), CRABTREE(MURANO) including making necessary connection as per direction of department.
11.12 Supplying and fixing of polished Brass Bracket of 18 S.W.G, 25 cm long cast back plate and brass lamp holder complete including connection as approved by the Deptt.)as required Without Lamp
LED11 Supplying,installation,testing and Commission of the following indoor Surface Mounted and Suspended Luminaires LED Luminaires complete with all accessories such as driver etc. and necessary connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department
11.4 Philips 15 W Astra Surface & wall mounted LED batten Model BN150W LED13S-6500 PSE OD GR or equivalent as approved by the Deptt.
LED12Supplying,installation,testing and Commission of the following LED lamp as directed by the department
12.25Philips LED bulbs non-dimmable 7 W or equivalent as approved by the Deptt.
LED16 Supplying, installation, connection, testing and commissioning of the following surface/suspended twin LED luminaries complete with all accessories including driver in the ceiling/ wall by providing necessary mounting bracket etc, and necessary connection with 1.5 sq mm. PVC. insulated S.C. copper conductor as required and as directed by the department.
16.1 Philips 40 W model BN 208 C LED 40/ (DL/ CDL/ NW) L 1200 FR or equivalent as approved by the Deptt. (twin 1200mm)
LED10 Supplying,installation,testing and Commission of the following indoor surface Mounted LED Luminaires complete with all accessories such as driver etc. and necessary connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department
10.3 Philips lighting luminaire 15 w GreenLED Surface Mounted Model DN170C LED10S-6500 PSU WH /DN170C LED10S-3000 PSU WH/ DN170C LED10S-4000 PSU WH or equivalent as approved by the Deptt.
13 NEW Supplying, installation, connection, testing and Commission of the following indoor decorative recessed typed LED down lighter luminaries complete with all accessories including driver in the false ceiling type Armstrong /Gypsum or similar ceiling mounting with necessary support and connection with 1.5 sq.mm. P.V.C. insulated S.C.copper conductor as required and as directed by the department. (600x600 module)
13.2 Philips model RC 380 B LED-30-6500/4000 PSE OD WH luminaries down lighter with latest LED technology or equivalent as approved by the Deptt..
22.7 Installation of earth station with 40mm dia and 4.5 mtr. long GI pipe with necessary GI reducing socket 40mmx20mm size locking arrangement with hinged cover plate, funnel, GI nuts, thorough bolts etc.for putting pipe and refitting with necessary enclosure on the top etc. as required complete.
22.12 Extra for using salt 5Kg and charcoal 64 Kg. for pipe earth electrode as required.
22.15 Supplying and laying with 6 SWG GI earth wire at 0.50 mtr. below ground level or conductor earth electrode including soldering, excavation work and refitting etc.as required complete.
22.31Supply, fitting & fixing 20 mmx3 mm Copper strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of Brass Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode copper strips and Lightning Arrestor etc. as specified and directed by the deptt.
ECBC1.1 Supplying including fitting fixing of following star rated A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection cable, as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. (ORIENT PSPO make / Usha make/ CROMPTON make/ Havells/ ATC/ V GAURD make)
ECBC1.1.1 Energy efficient 5-star 1200 mm sweep. ORIENT PSPO / Usha / CROMPTON / Havells/ ATC or equivalent make
27.2 Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department.
27.2.1.2 Power Flow 225 mm sweep (ORIENT make)
15.2 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
15.2.1 ABB, Schneider MG, legrand, Hager make)
15.2.1.412 way SPN double door
15.8 Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 double door surface mounting TPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt.
15.8.1 ABB, Schneider MG, legrand, Hager make)
15.8.1.1 4way TPN (4+12) double door
16.1Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
16.1.2 C Series (Schneider MG, legrand, Hager make)
16.6Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
16.6.2 C Series (ABB, Schneider MG, legrand, Hager make)
16.7Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
16.7.1 30mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager make)
16.8 Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz 4P RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
16.8.2 100/300mA sensitivity 4P RCCB (ABB, Schneider MG, legrand, Hager make)
17.22 Supplying including installation, commissioning of vermin and dust proof totally enclosed cubical indoor type floor/wall mounting compartmentalize panel board of size 1.50M X 1.60MX 0.40M made of 16 SWG1.66 m thick C.R. sheet and 40mm X 40mm X 5mm size angle having 4 no legs at the bottom complete painting with 2 coats of Red Oxide metal primer and 2 coats of enamel paint. The panel board is to be erected in 1 : 3 : 6 PCC foundation including brick soling / grouting etc. complete neatly Wiring done with provision for one no 400A 4pole MCCB or Switch Fuse Unit as incomer and provision for 8nos DP or TPN out going as specified and directed by the deptt. confirming to IP 43 protection comprising of the following electrical items
1. 40mm X 5mm 4 strip copper Bus - Bar 1.50 M length each
i 20mm X 3mm 4 strip copper Bus-Bar 0.5M each 8 sets
2.Multifunction digital meter of accuracy class<=0.5 for measurement of V/A/kW/KVAR/KwH/KVA
3. Pilot Lamp with integral ckt LED 110- 230 V (Red, Yellow,& Blue - 3 no
5. 2 A Slide fuse unit - 3nos
(Incoming & Outgoing Switch Gear of reqd. rating will be measured and paid separately)
16.13Supplying with fitting and fixing panel mounting open execution 25 KA 415V 50Hz 3P MCCB (Ics=Icu, adjustable Ir setting 0.7) without enclosure of the following capacity complete with making necessary connection as approved by the Deptt. as specified and directed by the deptt.
16.13.1 25 KA 415V 50 Hz 3P MCCB (Schneider, legrand, Siemens make)
16.23 Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt.
16.23.1 ABB, Schneider, legrand, L&T make)
32.1 Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make) .
32.1.3 3&1/2core A2XFY
32.1.3.7 150.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
32.5 Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make)
32.5.3.7 3&1/2core A2XWFY,A2XFY
32.5.3.7 150.00 Sq.mm 3&1/2 Core U.G. cable in 80mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Telephone Wiring :
45/SB8.39 Supplying with fitting and fixing of RJ-11 Telephone jack MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE including making necessary connection as per direction of department.
46/SB10.6 Supplying ,installation, testing & commissioning of 8 port Extension Card for 1190 ( SIEMENS or equivalent as approved by the Deptt.)
47/SB10.9 Supplying ,installation, testing & commissioning of Distribution Box 20 pairs with Krones ( SIEMENS or equivalent as approved by the Deptt.)
48/S10.14 Supplying ,installation, testing & commissioning of Open Stage 20T Digital Phone ( SIEMENS or equivalent as approved by the Deptt.)
49/S10.22 Supplying ,installation, testing & commissioning of 20 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
50/S10.20 Supplying ,installation, testing & commissioning of 2 pair Unarmoured Telephone Cable through existing conduit in surface/ recess system.
6.2 Supply and fixing of 25 mm dia 1.50mm to 2.00mm average wall thickness heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) on surface system including painting etc as required:
A. C. WORKS :
31/20.New Supplying with installation testing and commissioning of Hi -wall split (Cordless remote) air conditioner of the following capacity complete with indoor and outdoor unit, copper pipe and electrical connection up to 5 m between the room unit and out door unit as directed by the department. Approved make Carrier, Hitachi, Diakin, Mitshubishi. Warranty: Company will have to provide warranty on the entire product for twelve months from the date of commissioning. Additional warranty on Rotary & Scroll Compressor will be four and two years respectively. Service: Three free services will have to be provided by the company apart from the breakdown calls, if any.
20New.5 1.5TR (inverter split, with R-32/R410 gas) Daikin FTKP50 or equivalent
32/31.1 Supplying with fitting and fixing Voltage stabilizer of the following specification complete including making necessary connection as approved, specified and directed by the deptt. (SKYLAND / Vee-Dee / V GUARD / VERTEX/ INDO/ VENUS make)
31.1.8 4.0 KVA Automatic Input 90-280 V Out put 200-240 V
33/SB8.63 Supplying with fitting and fixing of Single Phase Modular Motor Starter switch of the following specification complete including making necessary connection as specified and directed by the deptt.
SB8.63.2 Overload Relay Range 9 - 15 Amps in 3 Module
(C ) FIRE DETECTION AND ALARMING SYSTEM
SB13.49 Supply & fixing of 2X1.5sq. mm. PVC insulated copper Armoured Cable on surface/ recess/ above false ceiling etc. as required. (ISI marked) )
SB13.1 Supply, Installation, Testing, Commission of Intelligent Fire Alarm Control Panel 2 Loop card inbuild,198 Addressable points per loop, total addressable devices 396, Integrated PSU with Battery Charger, Requires network card additionally for networking
SB13.7Supply, Installation, Testing, Commission of Intelligent Addressable Optical Detector with Remote Indicator Output With Base BRAND : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
SB13.5 Supply, Installation, Testing, Commission of Addressable Semi Flush Mounting Resettable (NonBreaking Glass) MCP, Supplied with Special Reset Tool BRAND : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
SB13.9 Supply, Installation, Testing, Commission of Addressable Wall Mounting Sounder / Hooter Cum Strobe Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
SB13.11 Supply, Installation, Testing, Commission of Addressable Input / Ouput Module Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
SB13.12 Supply, Installation, Testing, Commission of Addressable Loop Isolator Brand : MORLEY/FIRELITE/Apollo or equivalent as approved by the Deptt.)
SB13.14 Supply, installation, testing & commissioning of intelligent plug in photo electric Smoke Detectors having features like integral communication, dual LED for 360° viewing angle, walk test with address display etc. UL / LPCB approved, make : HONEYWELL, MORLEY IAS, Model : MI - PSE or equivalent as approved by the Deptt.
SB13.25 Supply, installation, testing & commissioning of Addressable Base Model - Detectors, LPCB approved, make - HONEYWELL, MORLEY IAS or equivalent as approved by the Deptt.)
(D) FIRE EXTINGUISHER :
29.2.2 Supply, Installation, Fixing of CARBON DIOXIDE Fire Extinguisher confirming to IS: 2878 with ISI Mark.(4.5 LITERS) BRAND: FIRESTOP / FIREND / FIRESHIELD
29.2.13Supply, Installation, Fixing of ABC Stored Pressure Fire Extinguisher with built – In pressure Gauge to know the Ready ness of the Extinguisher Squeeze Grip Handle As per IS:13849 with ISI mark (05 kg capacity) BRAND : FIRESTOP / FIREND / FIRE SHIELD
(E) SOLAR STREET LIGHTING SYSTEM
ECBC Supplying including installation, testing and commissioning of Solar Street light as per following specification and as directed by the Department.
15 W LED SOLAR STREET LIGHT [Confirming RDSO Specification No: RDSO/PE/SPEC/PS/0093-2008(Rev 0)]
SYSTEM SPECIFICATION
15 W LED based luminaries/fixture (1500 Lumens –typical).
LED Type: White High Powered LED’s 5500-6500 K temperature.
Automatic Dusk to Dawn Operate ion. Independent standalone Solar Street Lighting System.
Powered by a 12V, 80 Wp Solar PV Module confirming RDSO Part-I Approval & IEC: 61215
Certification. (Model: TBP 1280/ 1280M). (make: TATA BP SOLAR or equivalent)
12V, 75Ah @ C10, Tubular Plate Lead Acid Low Maintenance Battery with PP Container
(make: TATA BP SOLAR or equivalent).
Battery Box made of M.S fabricated with corrosion resistance paint.
6m height MS Pole with corrosion resistance paint.
Manufacturers Criteria:
Must have ISO: 9001 & ISO: 14001 Certification.
(As per Annexure A: Clause no: b, Page 10)
Must have integrated production capacity of Solar PV Cell & Module.
(As per Annexure A: Clause no: d, Page: 10)
Unit Cost Without Installation & Commissioning)
Installation & Commissioning Charges
RAINWATER HERVESTING SYSTEM :
33.1 RAINWATER HERVESTING SYSTEM :
33.1.1 Providing,Fixing, testing & Commissioning of Rain water Hervesting system for 1000 Sq.m roof area with 110 mm uPVC pipe of Class-3 conforming to IS:4985-200 (with uptodate amendment) with extra UV ray protection by Titanium Dioxide(TiO2) directing the Rainwater to Rainy filter/Pop-up raintap filter (Excluding Civil Works)
Storage of Rainwater
33.1.3 Water storage tank ISI Marked, conforming to IS:12701/1996 (with uptodate amendment). (Excluding Civil Works)
INTERNAL ROAD WORKS :
30.7. Providing and laying of inter locking concrete block pavement (ICBP) with cement concrete paver blocks as per IS 15658-2006 of thickness 80mm and 28 days compressive strength not less than 30 N/m over a layer of bedding sand of compacted thickness 30mm, laid either in stretcher/ running/ herringbone pattern of bonds as directed by the engineer and in proper level and grade and compacted with appropriate equipment such as plat vibrator along with spreading of a thin layer of joint filling sand to fill up the gaps between blocks including construction of edge restraint wherever required complete as per drawings and Technical specification clause 1504 of MORD.
DRAIN WORK :
19.4. Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified.
(ii) 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
LAND DEVELOPMENT WORKS :
1.4. Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary forest royelty, sales tax, land compensation, municipal gate fees, if any monopoly duty etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.
(I) Within Guwahati City
Non shedul. Raising low site around the building with approved soil obtained from excavation within the site including breaking clods, dressing etc. (profile measurement to be taken and 12.5% deduction for shrinkage to be made from total quantity) etc. complete as directed and specified.
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .