Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.7 LAccepted-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹23.7 L | L1 | Accepted-AOC Being Lowest |
| 2 | L2₹23.9 L+₹18,001.70 (0.76%)Rejected-Finance PLOT NO 10 9 OM VIHAR PHASE 1 A UTTAM NAGAR NEW DELHI 110059 | WEST DELHI | DELHI | 110059 | ₹23.9 L+₹18,001.70 (0.76%) | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹25.5 L+₹1.8 L (7.56%)Rejected-Finance | ₹25.5 L+₹1.8 L (7.56%) | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹25.6 L+₹1.8 L (7.69%)Rejected-Finance FLAT NO 602 THE ELEPHANT HEAD CGHS LTD PLOT NO 41 OPP AYUSHMAN HOSPITAL DWARKA SECTOR 10 SOUTH WEST DELHI 110075 | SOUTH WEST | DELHI | 110075 | ₹25.6 L+₹1.8 L (7.69%) | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹29.5 L+₹5.7 L (24.1%)Rejected-Finance | ₹29.5 L+₹5.7 L (24.1%) | L5 | Rejected-Finance Not Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
13 Oct 2021, 6:00 pmClosed
GE (Central) Delhi Cantt-10
GE (Central) Delhi Cantt-10
GE/C-36/2021-22 REPAIR /REPLACEMENT OF OLD ALUMINIUM /BATTEN TO CONCEALED COPPER WIRING ALONGWITH DB LED FITTINGS MISC E/M WORK AT RRRC ICHHAMATI LINE MAYNAMATI LINE AND PETTY REPAIR MISC E/M WORKS AT CHURCH ROAD KANDHAR LINE 61 CAV 48 MVH 105 TA 20
2021_MES_475488_1
GE/C-36/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (Central) Delhi Cantt-10
As per NIT
9 documents required · 9 mandatory
₹500
GE (Central) Delhi Cantt-10
₹90,000
Yes
29 Oct 2021
15 Sept 2021
20 Oct 2021
15 Sept 2021
13 Oct 2021
30 Sept 2021
15 Sept 2021 - 30 Sept 2021
Amount
Taking down care fully copper/aluminium point wiring from wooden batten or conduits (light, fan, socket or power) complete excluding fittings such as switches, sockets, ceiling roses, pendents, regulators, light fittings any type etc to be measured seperately) and making good disturbed surfaces of walls, floors etc complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through Existing PVC conduit, including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty and fabricated branded modular metal flush box / M S Steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
One light/fan point controlled by one way switch
One bell / buzzer point controlled by one bell push
One light point controlled by two Nos two way switches
One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 2 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge.
M & L for Point wiring complete with 1.5 sqmm single core PVC insulated FRLS cable 1100 volts grade with multi stranded copper conductor drawn through and including non-metalic rigid PVC conduit medium grade ISI Marked and all conduit accessories concealed in wall/ceiling/fixed to roof/truss/columns etc and including provision of 1.5 sqmm PVC insulated copper cable FRLS as earth continuty, fabricated branded modular metal flush box / M S steel terminal boxes, concealed in walls with suitable modular inner and outer plate / 3 mm thick laminated top sheet cover for housing switches , socket out let and fan regulators etc , all as specified and as directed for the followings:- complete all as specified and directed by Engineer in charge.
(a) One light/Exh fan point controlled by one way switch
(b) One bell / buzzer point controlled by one bell push
(c) One light point controlled by two Nos two way switches
(d) One 3 pin 5 Amps socket outlet point controlled by one way switch on independent board.
(e) One 3 pin 5 Amps socket outlet point controlled by one way switch on same board
All as per item No 4 but point wiring with 4 Sqmm single core copper cable and earth continuity wire with 4 Sqmm single core stranded copper cable for one three pin 15 socket outlet point on independent board complete all as specified and directed by Engineer in charge
Supply and fix white cover plate with frame 2 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 3 Module omplete all as specified and directed by Engineer in charge.
Supply and fix white cover plate with frame 4 Module omplete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 6 Amps 1 Way,1 module, 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement switch modular type 6 amp SP two way, 1 module complete all as specified and directed by Engineer in charge.
M&L in replacement Modular Bell push button SP with indicator 6 Amps, 1 module 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6 Amp socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement switch Modular type 16 Amps 1Way, 1 module with modular plate light marking 230V AC complete all as specified and directed by Engineer in charge.
M&L in replacement Modular socket outlet 2/3 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
M&L in replacement modular stepped type electronic fan regulator 120W, 2 module all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole one way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement switch piano flush button type single pole Two way 6 Amps complete all as specified and directed by Engineer in charge.
M&L in replacement bell push single pole 6 Amps complete all as specified and directed by Engineer in charge,
M&L in replacement switch piano flush button type single pole 16 Amps complete all as specified and directed by Engineer in charge .
M&L in replacement socket outlet, 2 in 1, 3 pin 6 and 16 Amp single pole complete all as specified and directed by Engineer in charge.
M&L in replacement socket outlet 6 Amp flush button type complete all as specified and directed by Engineer in charge.
M&L in replacement regulator electronic switch/socket type 5 steps suitable for 1200/1400 mm sweep 230 volts all as specified and directed.
M&L in replacement bell electric (dingdong) 230 volt, SP all complete all as specified and directed by Engineer in charge .
M/L in replacement insulated body, angle holder (metal ring) with back plate complete all as specified and directed by Engineer in charge.
S&F ceiling rose PVC/Polycarbonate type with three terminals complete all as specified and directed by Engineer in charge .
M&L in replacement sheet metal enclosure, single pole and neutral with a two pin and earth plug and socket 240 Volts grade 20Amps complete with one single pole MCB 'C' series 10/20 A capacity complete all as specified and directed by Engineer in charge.
Supply and fix LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply and fix in replacement LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply and fix in replacement LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
S&F in replacement of decorative type wall mounted luminaire (Comet) with unbreakable poly carbonate materials suitable for 1x14 watt LED bulb B22 base complete all as specified and directed by Engineer in charge .
Supply and fix surface ceiling mounted, LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed. .
Supply and Fixing LED bulb 9 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and Fixing LED bulb 14 watts, 900 lumens output, 6500K suitable for B-22 base complete all as specified and directed by Engineer in charge .
Supply and fix in replacement MCB DB SPN 12 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in replacement MCB DB SPN 8 way Horizontal, IP - 43 Protection double door 240 V AC 50Hz with for MCB SPN as incomer and DP/SP MCBs as out going with tinned copper bus bar ,neutral link earth link complete all as directed by Engineer -in- Charge.
Supply and fix in replacement MCB SPN 40 to 63 Amp Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fix in replacement MCB SPN 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fix in repair MCB SP 6-32 Amps 240 volts 10 KA 50 HZ 'C' curve complete all as specified and directed by Engineer in charge
Supply and fixing in replacement Ventilating Fan 250 mm sweep, 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of making holes and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fixing in replacement of declared BER by BOO Exhaust fan 300 mm sweep(steel Body) , 1250 RPM, non metallic resin body, single phase 240 volts AC 50 Hz and connecting up complete including louvers and provision of making holes and copper cable 3 core of size 0.5 sqmm for connection from ceiling rose to fan complete all as specified and as directed.
Supply and fix in replacement of declared BER by BOOwall mounted fan 400mm, 230 volts , 50 Hz 1420 RPM with 90 degree oscillation and having speed control by pull cord system all as specified and directed.
Supply and fix in repair MCCB 160 Amps, FP 415 volts 16 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 125 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply and fix in repair MCCB 100 Amps, FP 415 volts 25 KA 50 HZ with thermal magnetic setting complete all as specified and directed by Engineer in charge.
Supply & fix in repair factory made epoxy powder coated Load line Distribution Board TPN-4 ways with metal door (IP-43 protection) fabricated from minimum 1.6mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including insulated 200 Amp copper bus bar, Isolated neutral bar, standard DIN rail, Earth bar and cable ties for cable management, top and bottom removeable gland plates with knockouts and suitable for one TPN- MCCB 125/160 Amp as incomer and 32 to 63 Amp SP MCBs outgoing complete all as specified and conforming to IS : 8623.
S&F in repair Sub main wiring with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through and including 25 mm dia non metallic rigid PVC conduit and conduit accessories on surface of walls complete all as specified and directed. Note: Two meter of 4 sqmm and 01 meter of 2.5 sqmm shall be measured as one length.
Supply and fix in repair Sub main wiring complete with two runs of 4 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 2.5 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Two meter of 4 sqmm and 01 meter of 2.5 sqmm shall be measured as one length. .
Supply and fix in repair Sub main wiring complete with two runs of 6 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 4 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Two meter of 6 sqmm and 01 meter of 4 sqmm shall be measured as one length.
Supply and fix in repair Sub main wiring complete with two runs of 10 Sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable with one run of 6 sqmm single core PVC insulated FRLS cable 1100 volts grade, multistranded copper conductor cable as earth continuity conductor, drawn through existing metallic/ non metallic conduit in walls all as specified and as directed. Note: Two meter of 10 sqmm and 01 meter of 06 sqmm shall be measured as one length.
S&F plug top, 3 pin, 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge.
S&F socket 3 pin 20 amp earth metal clad (ISI marked) complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for single switch & socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F PVC Gang box surface type heavy duty suitable for two switch & two socket 5 Amps complete all as specified and directed by Engineer in charge .
S & F Gang box surface type heavy duty suitasble for 15 Amps switch and socket complete all as specified and directed by Engineer in charge.
M & L for in replacement only single core PVC insulated cable 1.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits, all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 2.5 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 4 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
M&L in replacement copper cable flexible 2 core PVC insulated of size 23/.0076 ll as specified and directed by Engr-in-Charge.
M & L in replacement for only single core PVC insulated cable 10 Sqmm FRLS 1100 Volts with copper multi stranded conductor and drawing in existing concealed conduits , all as specified and directed by Engr-in-Charge.
Supply only SS braided pipe of 12 mm ((internal) suitable for hot/cold water, 60 cm long with brass nuts and rubber washers complete all as specified and directed.
Supply only heating element of 2 KW any type with nut bolt washer complete all as directed.
Supply only heating element of 1.5 KW any type with nut bolt washer complete all as directed.
Supply only replacement of capacitor 3.15 Mfd, 240 V complete all as specified and directed.
Taking down old unserviceable down rod and supply and fix 1.5 mtr long down rod duly made out off Mild steel including taking down & refixing of existing ceiling fan of any sweep and make and making connection from ceiling rose to PVC connector complete all as specified and directed.
M & L tape roll 25mm size 25 mtr length all as specified and directed by Engr-in-charge.
Supply only replacement of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
S&F in replacement 45W High efficient LED Street light fitting with pressure die cast Aluminum housing and has lenses specially designed for Street Lighting with polycarbonate cover. System level efficacy of the Luminarie should more than 110lm/W. The color temperature is around 6500 K with a color rendering index of 70. The luminaire is IP:66 protected. It has an electronic driver complaint to IEC safety standards with a power factor>.0.9, voltage variation range 120-270V, THD<10%, High and low protection along with a surge protection of 4 KV including provision of suitable dia GI light grade pipe1.5 meter length bend to shape and necessary clamps etc for fixing the light fittings on wall fixed complete as specified and directed.
supply only hole fastner madeup of MS 6" long with complete nut bolt all as specified.Make:as per sample
Checking electrical points for continuous electric supply system and replacement of unserviceable spares for all electrical fixtures, ceiling/exhaust fans of any size and capacity and carrying out minor repairs, fixing screws, tightening of loose wires, any type renewal of small pieces of electric wire upto 1.00 mtr length and maintenance work complete on all working days including holidays all as directed by Engr-in-charge, at Bathroad area
Attending to Geyser complaints at site including checking and rectification of any electric fault/ water leakage and making good in all respects including minor repairs, replacement of unserviceable spares, burnt copper wire connections wherever required and repairing any type of switch, socket, plug top etc complete all as specified and directed. Notes for Item No. 69 and 70 (a) Supply only spares shall be measured and paid under relevant item of Sch 'A'/ BOQ (b) Contractors are advised to visit the sites before quoting their rates. (c) Materials for minor and maintenance repair works as directed by Engineer-in-Charge shall be supplied by the contractor within one week from the date of issue of work order. (e) Contractor shall provide and deploy adequate experienced Exp. professional to carry out day to day complaints and tradesman will remain present in Sanjay Vihar Complainet Cell from 0830 Hrs to 1800 Hrs from Monday to Sunday (02 Electrcian at Sanjay Vihar Complaint cell). In case of any breakdown/ emergency, contractor shall make arrangement to attend and rectify the complaints in odd hours on sunday/ holiday also. The rates quoted in sch 'A' respective items shall be deemed to be included and nothing extra shall be admissible on this account.Note:whatever be the nature of electrcal complaint the wholesole rectification responsibilty lies with the contractor. (f) Contractor shall be penalised @ Rs. 100/- per complaint per day, if he fails to attend the complaint within 8 hours.
Taking down sub main wiring off sizes etc complete all as specified and directed.
Supply, laying and drawing in existing concealed PVC rigid surfaces as per existing surfaces or as directed on walls 02 runs of IC x 6.00 sqmm (Main Cable and neutral) and one run of IC x 6.0 sqmm (as earth wire) of stranded copper conductor PVC insulated unsheathed cables of 1100 volts grade conforming to IS : 694 of 1990 complete including connection all as specified and directed. Make:- Havells ,Polycab, RR Kable
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 20 Amp complete all as specified and directed.
Supply only single pole and neutral enclosure with a two pin earth plug and socket complete with one single pole MCB 10 Amp complete all as specified and directed.
Supply only LED batten luminaire surface mounted, 4 feet system wattage of 22 Watts, > 2400 systems lumen outputwith lifetime of 50000 burning hours with 70% of its initial lumen maintained. CRI>80, Power Factor > 0.95, THD< 10%, colour temperature - 6500K, surge protection 2.5KV in CM, IP-20 protected, meets LED IS specifications, Class - 1, Short circuit and over circuit protection, voltage range - 150 to 270 Volts AC, temperature range 0 to 50 DegreeC and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire from ceiling rose to fitting fixed complete all as specified and directed.
Supply only LED batten luminaire surface mounted 2 feet system wattage of 10 watts and not less than 1000 lm with life time of 50000 burning hours with 70% of its initial lumen maintained. CRI > 80, power factor > 0.95, THD < 10%, color temperature > 6500 K , surge protection 2.5 KV in CM IP- 20 protected meets LED IS specifications, voltage range - 150 to 270 volts AC, temperature range 0 to 50 Degree C, system efficiancy at luminarie level ≥100 Lumens/watt and including connecting up with PVC sheathed 1.5 sqmm 3 core copper conductor flexible wire fixed complete all as specified and directed.
Supply LED 9/10 watts bulkhead fitting with powder coated die cast aluminium housing with glass/ non yellowing polycarbonate cover, IP65 Protection, System level efficacy of the Luminary is > 90 lm/W with a life class of 50,000 burning hours at L70 criteria, Power Factor >0.95, driver with Voltage range 150-270V, Temperature range 0 to 50 Deg, Driver efficiency >85%, THD<10%, CRI>80, Color Temperature-6000K, Surge protection of 2.5 KV, including connecting up with necessary PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only surface ceiling mounted, round LED down light fitting 12 watts with die cast aluminium housing and system wattage of 12W, system efficacy at luminary level ≥ 80 Lumens/watt, 50000 burning hours, 6500K color temperature with CRI >80, Power Factor > 0.90, Driver should meet IEC compliant for safety with multi stage high Isolate CC-CV operated driver with voltage variation range - 150 to 270 Volts AC, and surge protection of 2.5 KV, and including connecting up with PVC sheathed 3 core 1.5Sqmm copper conductor flexible wire fixed complete all as specified and directed.
Supply only 14W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz.
Supply only 9 W LED Bulbs, high energy efficiency LED luminaries to be fitted on existing holders 240 V,50 Hz.
Supply only of capacitor 2.5 Mfd, 240 V complete all as specified and directed.
Supply only batten holder including with connections complete all as specified and directed.
Supply only switch piano flush button type single pole one way 6 Amps all as specified.
Supply only switch piano 6 amp SP two way, ISI marked.
Supply only socket piano outlet 6 Amp flush button type all as specified
Supply only bell push single pole 6 Amps all as specified
Supply only switch piano flush button type single pole 16 Amps.
Supply only socket piano outlet, 2 in 1, 3 pin 6 and 16 Amp single pole .
Supply only Ceiling fan regulator electronic step switch type 120 Watt 230/250 Volts,ISI marked single phase complete.
Supply only switch Modular type 6 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6 Amp socket 2 moduler complete all as specified and directed by Engineer in charge.
Supply only switch Modular type 16 Amps one way 230V AC complete all as specified and directed by Engineer in charge.
Supply only Modular socket outlet 5 pin 6/16 Amp universal socket 2 module complete all as specified and directed by Engineer in charge.
Supply only Modular five stepped type electronic fan regulator 2 module 230V AC,ISI marked complete all as specified and directed by Engineer in charge. .
Supply only swich & socket combined 5 pin 6 Amp.
Supply only swich & socket combined 5 pin 16 Amp
Supply only ceiling rose surface PVC 65x50 mm type with three terminals. (For Exhaust Fans)
Supply only relacement plug top 16 Amps 3 pin 230- volts
Supply only Electric bell Ding-Dong AC 230 Volt ,ISI marked etc complete all as specified and directed.
Supply only MCCB 125 Amp 4 pole 16 KA at 415 V with fixed thermal magnetic release complete all as specified directed.
Supply only MCCB 100 Amp 4 pole 16 KA at 415 V with fixed thermal magnetic release complete all as specified directed.
Supply only double pole MCB 40 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
Supply only Single pole MCB 6 to 32 amp, 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for 10 KA breaking capacity, complete all as specified and directed.
Supply only MCB SPN 40 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 20 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 32 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only MCB DP 63 Amps 240 volts 10 KA 50 HZ 'C' curve complete.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 1.5 sqmm,ISI marked with approved colour code completed all as specified.
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 2.5 sqmm,ISI marked with approved coloured code completed all as specified
Supply only FRLS insulated single core unsheathed multistranded copper conductor 1100 volt 4 sqmm with approved coloured code completed all as specified.
Supply only heating element of 2 KW triangular type with nut bolt washer complete all as directed.
Supply only non return valve 15mm dia (ISI Marked) for Geysers of 50/35/25 Ltr capacity including GI Socket,Nipple, elbow ,bend etc and connecting up complete all as directed.
Supply only for safety pressure valve of size 15 mm dia, ISI marked for geysers complete all as directed by Engineer-in-charge.
S&F of thermostat for 25/35/50 ltrs capacity of geysers complete all as directed.
Supply only hylum sheets 3 mm thick (ISI marked) of the following sizes :- Make :-As per sample.
(a) Sheet 4" x 4" single cutting suitable for one piano switch
(b) Sheet 4" x 4" two cuttings suitable for two piano switches
(c) Sheet 4" x 7" three cuttings suitable for three piano switches
(d) Sheet 4" x 7" one cutting for 6 Amp socket and two cuttings for piano switches
(e) Sheet 8" x 10" incl cuttings for switches and sockets 6/16Amps as directed.
(f) Sheet 10" x 12" incl cuttings for switches and sockets 6/16Amps as directed.
Schedule of Credit
LAMBA ENTERPRISES
AMIT BROTHERS
NEERU ELECTRICALS
M/s Sohanil Construction
S. S. CONSTRUCTION CO.
Mani Control System
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .