| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance ROOM NO D 297 PART III GANESH MURTI NAGAR CUFF PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance ROOM NO 997 GALI NO 3 PART NO 3 GANESH MURTHY NAGAR CUFFE PARADE COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | Admitted-Finance |
| 4 | Admitted-Finance GE W COLABA MUMBAI | CHANDRAPUR | MAHARASHTRA | 441205 | Admitted-Finance |
| 5 | Rejected-Technical 5 6 MINTO ROAD ALLAHABAD 211001 | PRAYAGRAJ | UTTAR PRADESH | 211001 | Rejected-Technical Application for participating tender in firm letter head is not uploaded |
Tender Value
Refer Docs
EMD Value
₹99,840
Closing Date
12 Sept 2024, 6:00 pmClosed
GE (NW) NOFRA
Dr Homi Bhabha Road New Navy Nagar Colaba Mumbai
REPAIRS TO MS GATES FLOORING PLASTERING RAMP INTERLOCKING PAVER BLOCKS GALVALUME SHEETS AND REPAIR MAINT TREATMENT OF SUNKEN PORTION TILING GULLY FLOOR NAHANI TRAP CI PIPES EWC WC WHB AND ASSOCIATED ITEMS AT MD OTM ACCN OF AGE BRII UNDER GE NW NOFRA
2024_MES_666568_1
8295
Open Tender
Civil Works
Item Rate
270 days
Mumbai
Please refer tender documents
8 documents required · 8 mandatory
₹500
GE (NW) NOFRA
₹99,840
Yes
23 Sept 2024
18 Jul 2024
14 Sept 2024
18 Jul 2024
12 Sept 2024
1 Aug 2024
18 Jul 2024 - 25 Jul 2024
Amount
Note : 1. The tenderer shall note that before quoting his unit rate, all items of works shall be executed in high rise building (16th floor building) & including provision of necessary scaffolding & safety measures. (a) Functional tools & plants shall be carried by tradesman all time for attending any site. (b) Necessary ladder / cloth or any other material reqd. (c) Debris / site clearance immediately before leaving site. (d) Safety eqpt to be carried all time. (e) Scaffolding wherever reqd deemed to be included in quoted rates. (f) Contractor is solely responsible for any defect or after working situation arises, take leaving fresh water tap open or throwing of debris through window or shaft, Penalty levied as mentioned above. (g) In case of non-adherence of any of above fine/ penalty to be carried as under:- (i) 1st Time - Rs 200/- (ii) 2nd Time - Rs 500/- (iii) 3rd Time - Warning to contractor. (h) In case of 3 warning to contractor, it will be reflected in WLR for slow progress. (i) After painting cleaning of all floors, glass and Fixurniture by own arrengement. (j) Contractor has to attend daily complaints for particular day otherwise penality fo Rs 500/- per day will be leived on contractor.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
S& F for Framed work such as grills, gratings, angle iron, posts, pipe sections, railings etc. with ends of bars shouldered and/or riveted, or forged into spikes; door shutters with gusset plates, braces, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and similar work con- forming to Fe.290.Gde-E-165 at any height including necessary scaffolding complete all as specified and as directed.
S&F Plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections confirming to Fe 410 -W (Gde-E-250) quality A, complete all as specified.
M&L for preparation of new steel surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide complete all as specified incl all necessary scaffolding etc.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings.
S&F Plain galvanised mild steel sheeting 1.25 mm thick in ridges hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 and opening for rain water pipe to be provided fixed with MS Flat complete all as specified and directed.
Supply and fix Pre-painted Galvalume Aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws all as specified.
Demolition of cement concrete (unreinforced) in ground floor and in paving not exceeding 15 cm thickness (below or above ground level) complete all as specified.
M&L for cement concrete type B-1 , 1:2:4 (20 mm graded stone agg) as in floor and fisnishing cement concrete surface even, all as directed.
Material & labour for preparation of surfaces cracks of plaster internal/external of walls, ceilings/ chajjas upto 5mm wide, remove, loose plaster/concrete by suitable tools, filling cracks with crack paste compound and apply the second coat after 10-12 hrs of application of first coat complete all as specified and directed by Engineer-in-Charge.
Material & labour for preparing of old/new surfaces of walls/ceiling washing the surface thoroughly, filling the cracks, creaves with crack filling compound as suggested by the manufacturers and applying two coats of Rain coat paint of approved make. (shade to match the existing paint) including necessary scaffolding for work all as specified and directed by Engineer in Charge.
M&L for Preparation of old plastered surfaces of walls and apply two coat distemper oil emulsion over a coat 2 mm thick wall care putty over 0ne coat of primer , complete all as specified.
M&L for preparation of old wall surfaces and applying two coats of oil emulsion distemper complete all as specified and directed.
M&L for preparation of old plastered surfaces of ceiling and applying one coat of oil emulsion distemper on ceiling .
M&L for Preparation of old plastered surfaces of wall and apply one coats of Acrylic emulsion exterior paint of required shade : (one coat applied @ 1.67 ltr/10 sqm), complete all as specified., (For bldg upto GF to max of 15th Floor + upto height of mumty top ). [Note :-Necessary safety precautions need to taken before applying paint.]
M&L for Preparation of old plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint of required shade : (one coat applied @ 1.67 ltr/10 sqm), complete all as specified., (For bldg upto GF to max of 15th Floor + upto height of mumty top ). [Note :-Necessary safety precautions need to taken before applying paint.]
Dismantling of ceiling boards any thickness etc including aluminium grid frame work complete all as specified and as directed.
M&L for false ceiling made out of 600x600x 4 to 6 mm thick ceiliing board / tiles deep panel suspensor system made out of powder coated GI strips/sections main tee of size 23.50x40x0.63mm and cross tee of size 23.50x23.50x0.63mm and angle size 19x19x0.63mm including 3mm GI wire for suspending bolts necessary washers nut/clits/pin hook etc. for securing frame work to ceiling to the snap grid all as directed by Engr-in-charge including provn of necessary holes / cuttings for providing light/fan as required including making necessary recesses / projected pattern complete all as specified and as directed.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water, upto 15th floor of bldg.,complete all as specified.
M&L for Rendering 15mm thick cement plaster in cement mortor 1:6 on brick or concrete surfaces in patches, surfaces to be finished even and smooth without using extra cement,complete all as specified.
M&L plastering 10mm thick in CM 1:3 in ceiling finishing even and smooth without using extra cement,complete all as specified.
M&L for Rendering 15mm thick on brick work or concrete surfaces in cement mortar 1:4 finished even and fair including mixing integral water proofing compound in the proportion as mentioned in manufacturer's instructions & upto 15th floor of bldg.,complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and disposing the rubbish to the out side of MD land
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick(square/Rectanglar) area of each tiles exc 0.11 Sqm but n exc 0.18 Sqm in floor including 20mm thick screed bed or bedding layer for laying floor finishes in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified.
M&L for coloured glazed ceramic tiles 450x300x7 / 350x250 x7 mm mm thick but as on vertical surfaces such as skirting/dado including 15 to 20mm thick backing coat in CM 1:4 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Supply only integral water proofing compound complete all as specified.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of 1 to 2 mm thick wall care putty upto 15th floor of bldg.,complete all as specified.
M&L for Preparation of new plastered surfaces of wall and apply two coats of Acrylic emulsion exterior paint of required shade : (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm), complete all as specified. Note : Work carried out upto 16th floor of building.
M&L for preparation of newly plastered surfaces of ceiling and applying three coats of white wash on ceiling upto 15th floor of bldg.,complete all as specified.
S&F 500 lit capacity rotational moulded polyethylene water storage tanks (cylindrical, vertical with closed top ) hoisted and fixed position all specified in SSR Part-I, with and including 20mm dia. Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed, screwed for iron pipes and fixed; including disconnecting and dismantling/ taking down of existing old unserviceable water storage tank from terrace, complete all as specified and directed by Engineer-in-Charge.
Dismantling stone slabs and tiles of any description or thickness in floors laid bedded and pointed in any mortar, complete all as specified.
M&L 16 to 18 mm thick Granite (of any type) work (table rubbed and polished) as in steps, jambs, pillars, window- cills,cooking platforms, working table, floors and like over and including 20 mm thick screed bed or bedding layer in cement mortar (1:4), including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite incl moulding and rounding all as directed.
M&L for machine cut cudappa stone slab 20-25 mm thick laid over screed base in cement and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as directed.
M&L, for mirror polished machine cut kota stone slab flooring 20-25mm thick over cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
M&L, for machine cut kota stone slab flooring 20-25mm thick in riser / treads of steps in single piece, skirting, dado and pillar laid over cement screed and jointed withover cement screed bed in CM (1:4) 15mm thick, & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing & polishing complete.
M&L for replacement of cement concrete interlocking paver tiles 60 mm thick having glossy finish (colour and pattern approved by GE) (tested as per IS 1237-1980) laid over and including 50 mm thick dry sand cushioning and voids filled with dry and surface compact, including compaction by means of surface vibrator & removing of old tiles, complete all as directed.
Taking down chowkats or frames but n exc 1.5 sqm each but with shutters (without taking off shutters from the frame) , complete all as directed.
Taking down chowkats or frames exc 1.5 sqm each but n.exc 4 sqm with shutters (without taking off shutters from the frame) , complete all as directed.
Taking down shutters of any description exc 1 sqm and n exc 2 sq.m each, complete all as directed.
M&L 2nd class HW Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed
S&F 35mm thick Flush shutters, solid core construction, with particle board core and plywood face panels, commercial type on both sides, complete all as specified & directed.
M&L for preparation of newly wooden surfaes of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer incl preparation of surfaces.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specifiecation and drawings.
S&F factory made solid panel PVC door shutter 30mm thick style consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20mm width struck inside with solvent cement forstyle and plain colour PVC sheets for top rail, lock rail and bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles & rails with suitable PVC sheet beading and jointed together with solvent cement supply & fixing in the frame at site. complete all as specified
S&F powder coated (colour of coating as directed) aluminium (minimum 25 micron thickness of coating) of various section as required/suitable for doors, window & partion/Ventilator (sliding /or openable type)etc including fixing and making the frames hinges to receive glass/wire gauge etc. Complete incl all fittings like jointing cleats, glazing clips, rubber neoprene packing. anodised aluminium snap beading screws etc. rubber beading, clips locking arrangement, handle, sealant etc all as specified and as directed.
S&F aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and directed.
S&F aluminium grill with and including suitable aluminium anodised frame F/H section as required manufactured by approved make as per design No DG- 104, 7.5 mm thick all as specified and as directed by Engr- in- charge.
S&F 300 mm long aluminium alloy, sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet cast or extruded section and fixing bolts and sliding bolts all as specified.
S&F for aluminium anodized barrel tower bolts 200 mm of extruded section.
S&F 150 mm size aluminium alloy handles, cast type anodised, ISI marked all as specified.
S&F butt hinges 100 mm stainless steel hinges medium weight and fixed.
S&F 150 mm long floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring all as specified
Hacking out old broken glass (any thickness, size, quality or description) from iron frames glazed with putty or wooden beads complete all as specified. ( Work carried out upto 7th floor of building either from inside or from outside)
S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 Sqm in each pane all as directed. ( Work carried out upto 15th floor of building either from inside or from outside)
S&F in repairs aluminium alloy wire cloth 0.45 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with aluminium wire staples all as specified and directed.
S&F as in repairs aluminium anodized barrel tower bolts 200 mm of extruded section and fixed.
S&F as in repairs 150 mm size aluminium alloy handles, cast type anodised, ISI marked all as specified.
S&F as in repairs Steel rolling shutters 1mm thickness of laths, with out ball bearing, as specified including top cover, an?choring rod, hasp and staple and one shop coat of primer; erected in position as indi?cated, complete: push pull or manual type , complete all as specified.
Dismantling boarding, any description, fixed in any position with nails, complete all as specified.
S&F PVC wall panelling consisting of 5mm thick wood grain printed PVC sheet and fixed over GI running channels 50mm wide and 0.6mm thickness at every 1m interval , fixing over brickwall /concrete walls with screws and all corners, top and bottom portion of PVC lining covered with L/T shaped PVC sheet of same colour/texture including all necessary cuttings near switch boards and other fixtures if fitted over wall, complete all as specified.
Material & labour for providing in repairs water proofing treatment with 4mm APP (Atactic polypropylene) modified polyester(bituminous) membrane reinforced of 3.5Kg/Sqm with non woven polyester mat of weight 160 gms/sqm as center core and without multiple layers of polyethylene, finished on top and bottom with 7 micron thick flammable polyethylene applied by thermo fusion using LPG torch on the bottom portion of the membrane, after applying a coat of bituminous primer @ 0.25 Kg/Sqm over roof (An overlap of 100mm and 150mm shall be provided on sides and ends respectively) and applying two coats of bituminous aluminium paint on APP sheet including removal of old damaged APP sheets including 10mm thick cement plaster on roof in CM (1:3) & finishing even and smooth without using extra cement to receive APP membrane including cleaning of exposed surface of slab by wire brush, remove dust and removing from MoD land complete all as specified and directed.
Treatment of sunken floor slab compraises of the following specifications and all as specified :-
(i) M&L for cleaning the sunken/lowered portion of RCC slab surface (including vertical total depth plus skirting height) of floors by wire brush, chisel out any mortar sticking to the surface and brooming completely. 40mm thick avg PCC 1:2:4 type B-0 using 12.5mm graded aggregate as in padding concrete to achieve proper slope including cutting holes in bricks or RCC wall for spout (Cost cutting holes and pipes shall be measured and paid separately)
(ii) Rendering of uneven surfaces with 6mm thick CM 1:4 mixed with integral water proofing compound @ 3% by wt of cement consumed. Fill it with water and check dampness and seepage. Where dampness/seepage is noticed, nozzles shall be fixed and grouting carried out.( WPC shall be measured & paid separately)
(iii) All junctions points of side wall where CI/GI pipes are passing through shall be sealed with epoxy putty.
(iv) After drying putty, wash the slab and sides of sunken portion with water and make it dry and clean.
(v) M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.(This item shall be measured and paid separately)
(vi) Plaster the bottom and sides up to bottom of the skirting with minimum 20mm thick CM 1:4 mixed with integral water proofing compound 3% by wt of cement consumed as per manufacturer's specification including rounding of corners and junctions sloping towards spout.( WPC shall be measured & paid separately)
(vii) All pipes laid in sunken portion shall be covered with 50mm thick PCC 1:3:6 all round after painting with anticorrosive paint (this item shall be measured & paid separately).
Note :- Test the water proofed area (ponding test) by filling water for at least 72 hours and tested for leakage seepage and to the entire satisfaction of GE. Cost of testing is included in the rates quoted above.
Cutting holes in bricks or RCC walls exc half brick wall built in cement mortar including making good after inserting and setting spouts all as specified.
S&F GI pipe 25mm dia medium grade laid on sunken floor complete all as specified and direced by EIC.
M&L for applying two coats of polymer modified cementious water proof coating as per manufacturs instruction to bottom and vertical sides up to finished floor level+100mm height. The thickness of two layer shall be 1mm. When the second layer is still sticky, coarse sand spray shall be carried for the vertical and bottom surface of the sunken portion all as specified and directed.
M & L Injection grouting in RCC slab shall be cast/laid to the slope as directed/as per site conditions. After RCC slab is laid, cured and fully set, water shall be ponded in the sunken slab portion as per specified ponding test. The location of seepage/leakage, if any, shall be identified and marked. The portion of the slab where leakage/seepage is observed shall be repaired with grouting at contractor's expences. The area of dripping/leakage shall be cleaned to expose the surface. Mark the spots for injection grouting. If leakage is through a crack, mark grouting points along the crack in a staggered manner. If the leakage is across the area mark grouting spots in a grid pattern. Drill grouting holes so as to neatly fit the injection packers. Drilling to be done at an angle of 45 to the plane of grouting surface. Fix PVC/MS nozzles in the low viscosity, injecting polyurethane resin/epoxy grout using a grouting pump. Repeat the process after 1 or 2 days if the leakage continues at some point. allow to cure for 24 hours and seal the grouting holes appropriately using epoxy putty etc complete all as specified and as directed.
M&L for Non skid coloured ceramic tiles 7 to 8 mm thick(square/Rectanglar) area of Each tiles exc 0.06 Sqm but n exc 0.11 Sqm in floor including 15 mm thick screed bed or bedding layer for laying floor finishes in CM 1:6 etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, complete all as specified.
M & L Glazed ceramic tiles in vertical surfaces 200x300mmx7mm thick including over 15mm thick rendering of cement mortar (1:4) for laying floor finishes set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed by the Engineer-in-Charge.
M&L PCC 1:7:12 with brick aggregate as in lean concrete/filling concrete
Taking down Cast iron pipe of dia upto 100mm fixed on wall or in floor including all fittings upto 15th floor of bldg. complete all as specified.
S&F 100 mm dia sand cast CI soil waste & vent pipe in any length with ears and jointed with neat cement paste fixed to wall upto 15th floor of bldg., complete all as specified.
Taking down Cast iron pipe of dia 100mm fixed on walls and re-fixed on wall including all fittings after cleaning properly and paint with bitumenious paint upto 15th floor of building complete all as specified.
Taking down Cast iron pipe of dia 75mm fixed on walls and re-fixed on wall including all fittings upto 15th floor of building complete all as specified.
S&F 75 mm dia sand cast CI soil waste & vent pipe in any length with ears and jointed with neat cement paste fixed to wall upto 16th floor of bldg, complete all as specified.
S&F 100 mm dia sand cast CI soil waste pipe in any length with or without ears and jointed with neat cement paste, laid in trenches or in floors.
S&F 75 mm dia sand cast CI soil waste pipe in any length with or without ears and jointed with neat cement paste, laid in trenches or in floors.
M&L in repair 100mm cast iron Nahani / Floor trap with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) upto 15th floor of bldg., complete all as specified.
S&F in repair 100 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste , complete all as specified.
S&F in repair 75 mm dia sand cast CI bend of any radius with ovel access door and jointed with neat cement paste, complete all as specified.
S&F in repair 100 mm dia branch piece single length branch of any radius with ovel access door and jointed with neat cement paste , complete all as specified.
S&F in repair 100 mm dia double branch piece branch of any radius with ovel access door and jointed with neat cement paste, complete all as specified.
S&F in repair 75 mm dia branch piece single branch of any radius with ovel access door and jointed with neat cement paste.
S&F in repair 75 mm dia branch piece double branch of any radius with ovel access door and jointed with neat cement paste.
S&F as in repairs WHB/Kitchen sink collapsible waste pipe out let upto Nahani trap complete.
S&F in repairs 15mm pillar taps, cast copper alloy with captain heads chromium plated screw down high pressure with long screwed shanks and fly nuts screwed for iron pipe and fixed
S&F as in repairs 10 ltr capaciaty PVC low level flushing cistern 10 litre capacity with 32mm bore polythene flush pipe of sufficient lenght including internal fitting (valve less syphonic) etc. upto 15th floor of bldg. complete.
Removing and refixing only high or low level flushing cistern (inclusive of brackets),and connection to pipes .
Removing and refixing Vitreous china wash basin white flat back any size complete.
S&F in repairs white vitreous china wash down water closet pan with PVC white seat cover with mild steel chromium plated or aluminised hinging device including connection to down pipe PVC connection and flushing pipe all as specified.
S&F in repairs, Plastic water closet seat covers, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device.
S&F as in repairs Wash hand basin vitreous china White flat back size 550mmx400mm including cast iron brackets, chromium plated waste coupling, PVC connection, waste pipe up to floor trap etc in repair all complete as specified.
S&F in repairs CP bib cock 15 mm bore complete all as specified and directed.
S&F in repairs health faucet ABS Body with 8 mm dia 1 mtr flexible tube and wall hook.
S&F in repairs aluminium anodised tubular towel rail 20mm dia D type 60 cm long between flanges , complete all as specified.
S&F as in repairs brass chromium plated shower rose 125mm size, including fixed to steel tube, complete all as specified.
Taking down and refixing 15mm bore stop cock / bib tap/ pillar tap/shower/ health faucet etc. to iron /CPVC pipe, complete all as specified.
S&F in repair 100mm dia CI sanitary connection- short connections pipe of length upto 300mm
S&F in replacement Vitreous water closet (orissa pattern) white , front or back inlet any pattren complete all as directed.
S & F as in repairs Cast iron floor trap 75 mm dia, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2;4) all as specified
Removing and refixing only Vitreous china EWC complete any size complete.
Resecuring or easing & adjusting without taking down shutters of any description exc 1 sq. m and n exc 2 sq. m Each
M&L for anti termite treatment At points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same
Removing of dismantled/ demolished material / old debris/tiles etc by mechanically or manually, outside MD land as and when directed.
S&F GI water tubing 20mm bore medium grade (ISI marked) including with all fittings and fixed to wall /ceilings laid in floor or concealed upto 16th floor of bldg. including taking down old GI tubing complete all as specified and directed.
S&F GI water tubing 15mm bore medium grade (ISI marked) including with all fittings and fixed to wall /ceilings laid in floor or concealed upto 16th floor of bldg. including taking down old GI tubing complete all as specified and directed.
S&F 20mm bore of CPVC pipes having thermal stability for hot & cold water supply including all plain and brass threded fittings fixed of required sizes including with all fittings and fixed to wall /ceilings with suitable clamps, laid in floor or concealed of 20mm size (in high rise building (upto 16th floor)including scaffolding) and incl. taking down old tubes of any desc. complete all as specified and directed by Engineer-in-Charge.
Taking down eaves gutters and rainwater pipes of any dia (any size or pattern ) including all fittings, heads, shoes, bends, swan necks etc (Measured overall as fixed along the centre line over fittings and accessories) & ht. upto 16th floor of bldg., complete all as specified.
S&F 160 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc & ht. upto 16th floor of bldg., complete all as specified.
S&F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls including fixing clips, bends, elbows, shoes etc & ht. upto 16th floor of bldg., complete all as specified.
S&F PVC (SWR) bends of 160 mm bore & ht. upto 16th floor of bldg., complete all as specified.
S&F PVC (SWR) bends of 110 mm bore & ht. upto 16th floor of bldg., complete all as specified.
M&L for Washing, rubbing down and stopping of distempered and painted surfaces of old wall and apply two coat distemper oil emulsion over a coat of primer over a coat 1 to 2 mm thick wall care putty , complete all as specified.
M&L preparation of old distempered surfaces of walls and applying one coat of oil emulsion distemper on walls etc all as specified.
M&L preparation of old surfaces of ceilings by washing, rubbing down and stopping of distempered surfaces and applying two coat of white wash etc all as specified and directed.
M&L for Cleaning the wall surfaces throughly, it should be free from oil, grease, dust, dirt, fungus and moss and thorough wire brushing followed by sanding with emery paper, Remove the existing paint, neroo or instant lime, etc. while treating internal damp walls. Fill the cracks & grooves with Dampguard Classic of approved make and cement modified putty & allow it to dry for at least 24 hours. Apply one coat of Dampguard Classic followed by a coat of Dampguard Classic Putty prepared as per manufacturers instructions and finally second coat of Dampguard Classic as per manufacturers instructions
M&L for applying white cement mixed with polymer bases water proofing compound inside the floor/nahani trap and inside P/S trap, complete.
M&L for preparation of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as speciified.
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint complete all as specified.
S&F in repairs fancy type drapery rods, powder coated aluminium of 20-25mm size with / including fixing brackets, Knobs rollers etc.all as specified and directed.
Supply and fix in repair white rectangular PVC water storage tanks (Loft tank) of capacity 300Ltrs with complete fitting including fixing 03 Nos tank nipples of GI/ PPR with washer for out let and inlet all as per manufacturers instructions including disconnecting service connections/over flow pipes and removing old tank complete all as specified and directed.
Supply and fixing in repair PVC modular 20mm thick as in proflie including 'C' channels, aluminium U clip all around the profile suitable for 300 ltr capacity loft tank ,complete all as specified and directed.
Supply and fixing as in repairs Mild steel angle iron section (Fe 290 Gde E 165) fixed independently, without connecting plates, etc incl cutting to required length, drilling, welding etc and embedding in Brick work incl Cutting holes into or through brick walls built in cement mortar and making good in cement mortar 1:3 as required as in loft Water tank base in bathrooms/kitchens etc complete all as specified and directed
Water Proofing Treatment to Sunken Floor are as under: - (a)Cleaning the surface of any description with wire brush, detecting sources of leakage/ seepages and removing/ taking down unsound treatment/ surface. (b)M&L for making holes with drill machine of dia 18mm for carrying out non-destructive waterproofing treatment to floors, sunken portion of toilet/ bathroom and junctions of floor and walls of bath/WC and floor traps (combined unit) by using construction chemical method as hydrophobic PU grouting with first course of injection MDI based PU foam and second course of injection with PU plain all as per manufacturers instruction etc and M&L for fixing the metallic packer for hydropobic PU foam sealer as per manufacturer specification. [Note :The PU foam and PU plain shall have 100% solids and solvant free and shall expand 30-40 times its volume at liquid stage in presence of water, the PU plain injection shall have minimum 100 CPS viscosity and shore hardness minimum 50D.]
M&L for tile joint chemical cleaning and re-grouting carefully by washing the exisiting tiles with heavy duty tile cleaner approved make or Equivalent cleaner, again washing with fresh jet water, scratching the joints and filling the same with (White/ matching colour) epoxy tile grout of approved make or Equivalent as approved by GE, curing, cleaning the surface etc, complete all as specified and directed.
Supplying and fixing in repairs brass float valve flat type of size 15 mm bore, high pressure with polythene float & fly nut complete, screwed for GI pipe of following sizes including necessary GI fittings complete all as specified.
K.C.P ENTERPRISES (BID ID -3077663)
GANGAJAL (BID ID -3076047)
satguruenterprises (BID ID -3084863)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .