Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER FOR THE WORK | |
| 2 | L2₹36.9 L+₹1.9 L (5.43%)Rejected-AOC 2645 SAYAROLI BAZAR NASIRABAD RAJ 305601 | NASIRABAD | AJMER | RAJASTHAN | 305601 | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 3 | L2₹37.8 L+₹2.9 L (8.22%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹42.4 L+₹7.5 L (21.4%)Rejected-AOC 37 222 BUNDU KATRA AGRA UP | AGRA | UP | L4 | Rejected-AOC OTHER THAN THE LOWEST BIDDER |
Tender Value
₹43.5 L
EMD Value
₹87,060
Closing Date
21 May 2020, 6:00 pmClosed
CWE BHOPAL
HQ CWE BHOPAL, SI LINES, BHOPAL, PIN-462001
SPL REPAIR/ REPLACEMENT TO EXTERNAL WATER SUPPLY INSTALLATIONS AT NASIRABAD
2020_MES_340942_1
83509
Open Tender
Pipes and Pipe related activities
Item Rate
180 days
NASIRABAD
AS PER NIT CONDITIONS
4 documents required · 4 mandatory
₹500
GE NASIRABAD
₹87,060
Yes
23 Jul 2020
27 Apr 2020
27 May 2020
27 Apr 2020
21 May 2020
9 May 2020
Amount
Dismantling of cement (corrugated or semi corrugated) sheeting, any gauge, thickness, including as in roofing covering complete all as specified and directed
Dismantling of timber scantling 40 Sq cm and over in section as in unframed work in any position complete.
Dismantling of wrought iron or mild steel work of any description not otherwise provided for in any position complete. Note: weight shall be verified by the GE.
Demolition of cement concrete (un-reinforeced) in ground floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed.
Demolition of Brickwork or stone/ boulder masonary, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified and directed.
Dismantling of floor, hearth or wall tilings incl cement mortar bedding and rubbish off the premises complete all as specified and directed.
Taking down cement or cement lime plaster on stone / brick wall etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) n.exc 1.50 sqm each all as specified and directed.
Taking down chowkhats or frames with shutters (without taking off shutters from the frames) exc 1.50 sqm and n exc 4.00 sqm each all as specified and directed.
Taking down shutters of any description .exc 1 sqm butt n.exc 2 sqm each and removing to store all as specified and directed
S&F framed work as in roof trusses purlin, rafter and batterns of angle or other section with gusset plates , rails , braces, etc complete of Fe 410-W (Gde E-250) , drilling for fixing of steel sheeting or other covering doors etc to be prepared for hanging Note: Weight shall be verified by the GE.
S&F rolled mild steel in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, fixed with angle cleats or other connecting platesand similar works and fixing complete Fe-410W (Gde E 250 quality A) Note: Weight shall be verified by the GE.
S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 as specified & directed. Note: Weight shall be verified by the GE.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre painted galvatume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of colour having tensile stength of 550Mpa as in roof coverings/cladding to wall, valley gutter and similar works fixed with self tapping screws as specified
M&L for Brickwork with fly ash modular bricks, straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as spd and directed.
M&L for Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM 1:6 complete all as spd and directed.
Ditto all as per item no 17.00 above but except stone complete all as spd and directed.
Extra over stone walling for hammer dressing with maximum depression on face from straight edge held against the dressed surfaces n exc 20mm to face of Granite or Trap stones and dressing of face beds and joints, as specified of random rubble walling, uncoursed or brought upto courses.
M&L for 25 mm thick PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in floors complete all as specified and directed.
M&L for Non-skid ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors, set and jointed in neat cement slurry and pointed in coloured cement to match with tile laid over and including screed bed or bedding layer, 15 mm thick in CM (1:6), complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile laid over and including screed bed or bedding layer 15 mm thick in CM (1:6) complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in vertical surfaces such as skirtings ,dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match with tile laid over and including screed plaster 10 mm thick in CM (1:4) complete all as specified and directed.
M&L for glazed ceramic colour tiles, 7mm thick in vertical surface exc 0.11 sqm but n exc 0.18sqm, set and jointed in neat cement slurry and pointed in white or colou cement to match fixed over 10mm thick CM (1:4) as in backing coat complete all as specified and directed.
M&L for machine cut Kota stone slab, 20-25mm thick over & incl. 15mm thick screed bed in CM 1:6 as in floors, laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab incl. rubbing with mirror polish complete all as specified.
M&L for machine cut kota stone slab in skirting/ steps/ risers of reqd size, 20 to 25mm thick & incl screed plaster 10mm thick in cement mortar 1:4 laid and jointed with grey cement slurry mix with pigment to match the shade of the slab including mirror polish complete.
M&L for PCC (1:3:6) type C-2 (using 40mm graded crushed stone aggregate), 50mm thick as in plinth protection finished fair & even laid in alternate bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed.
M&L for cement conc 1:3:6 (Nominal mix) type C-1 (using 20mm graded crushed stone aggregate) as in surface channel and drain all as specified.
Extra for fair finishes drain or channel 30cm and over in girth in cement concrete using extra cement including formas/ moulds/ metred/ stopped ends etc.
S&F machine cut Kota stone slab flooring of size not less than 20-25mm thick for cover of pit as per required sizes except stone complete all as specified.
M&L for 75mm thick, PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base to interlocking tiles/ floors complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment coloured,reflective type of approved quality laid over and incl 25 mm thick sand cushion vibrated with mechanical vibrator complete all as specified and directed.
M&L for Hard core, broken to gauge n exc 63 mm complete all as specified and directed.
M&L for 100 mm thick PCC (1:2:4) type B- 2 (Using 40mm graded crushed stone aggregate) complete all as specified and directed.
M&L for Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade 'A' complete all as specified and directed.
M&L for PCC ,1:3:6 type C1, (using 20 mm graded crushed aggregate) as in in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed bed blocks for embedding hold fast etc.
Dismantling loose/ disintegrated portion of RCC Chajjas, bends shelves, beams balconies and similar work at any position or any height and dubbing out with PCC 1:1.5:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished required shape including applying anti corrisove paint on exposed surface and provision of necessary supports form work and including 10mm thick plastering in CM 1:4, finished fair and even, complete all as specified and directed.
Raking out joint/ pointing to random rubble or polygonal rubble stone masonary uncoursed or brought upto courses built in CM and M& L for keyed pointing in cement mortar (1:4) complete all as specified and directed.
M&L for rendering in cement mortar (1:6), 15 mm thick on other than fair faces of brick work surfaces finished even and smooth, complete all as specified and directed.
M&L for rendering in cement mortar (1; 4) 10mm thick as in ceiling finished even and smooth , complete all as specified and directed.
M&L for rendering in cement mortar (1: 4), 15mm thick on fair faces of brick work or concrete surfaces, finished even and smooth complete all as specified and directed.
M&L for 15mm thick rendering on stone masonary surface in (CM 1:4,) finished fair and even without using extra cement complete all as spfd and directed.
M&L for providing precast cement concrete louvres and jallie in repairs, 35mm thick (measured solid) 1:2:4 Type B0 (Using 12.5mm thick graded stone aggregate Set in cement mortar 1:4 , including all mould- ings
M&L for preparation of newly plastered surfaces of walls and apply three coats of white wash complete all as specified and directed
M&L for preparation of newly plastered surfaces of ceilings and apply three coats of white wash complete all as specified and directed
M&L for preparation of newly plastered surfaces of walls and apply two coat of cement base paint , complete all as specified and directed
M&L for preparation of newly plastered surface of wall and apply two coats of tractor acrylic washable distemper or equivalent over a coat of 1mm average thick wall putty, and a coat of decoprime cement primer all as specified & directed
S&F Solid PVC moulded door frame of size 50mmx47mm made out of 5mm prelam coloured PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with prelam sheet as reinforced with MS square tube and fixing in opening as specification & drawing complete all as specified and directed.
S&F factory made solid PVC moulded door shutter with wood free EPS, 28 to 30mm thick, (styles) with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam (Nut Brown Colour) PVC Sheet on the front face & 2mm prelam (Nut Brown Colour) PVC Sheet on back face, and fixing in the frame at site as per specification and drawings on page 161 of SSR (Part - II) 2010 complete all as specified and directed. Note : Cadmium screws to be used for fixing and fixtures
Taking down old u/s steel window/ventilator and S&F steel window/ ventilator glazed and gauged (combination) with side hung/ top hung shutters incl box type / projecting type hinges, and steel peg stay, handle & locking arrangement and frame made out of 1.25mm thick pressed steel frame including Guard bars and necessary cooler arrangement in window complete all as shown in drg No. CEBZ/TD/14/11 sh No 1/7 to 7/7 & specified and directed.
Dismantling boarding of any description fixed with nails in any position and M&L for 18/19mm thick prelaminated particle board , exterior grade - prelaminated both sides with decorative choice laminations, fixed with screws, including teak wood lipping 19 x 6mm thick fixed with nails in shelves, partition and pelmet boxes, cupboard, shelves, almirah book cases, toilet boxes, racks, dressing tables,cup board shutter and similar works all as spepcified and directed.
S&F continuous (Piano) hinges, mild steel, bright finish, width of flaps (when open) 30mm complete all as spfd & directed
S&F stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks or stainless steel wire staple all as specified and directed
S&F sheet glass, ordinary quality, 3mm thick fixed with oil putty size of glass not exc 0.50 Sqm in each pane complete all as specified and directed.
S&F figured glass, pin headed type, 3mm thick & glazing with oil putty in n. exc 0.5 sqm in each pane complete all as spd & directed .
S&F MS butt hinges, medium weight, cold rolled, ISI marked of size 100 mm, complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section all as spd & directed.
S&F 150mm long Extruded aluminium alloy handles, fabricated type, anodised as spd & directed.
S&F hasp & staple 100mm size safety type, aluminium anodised with mild steel hinges pin including bolt of hinge plate & fixed with screw complete all as specified & directed.
S&F Powder coated aluminium door shutters,with frame of aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws, double action floor door spring hydraulically regulated including 5.5mm thick glass etc. complete all as specified.
S&F powder coated aluminium window and ventilator shutter, sliding/ fixed/side hung type with or without sash bars including alu guard mesh/bars necessary joining cleats,glazing clips ,rubber packing ,anodised aluminium snap beading,screws, duco pattern aluminium grill etc. complete all as specified and directed.
S&F Rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete conforming to Fe 410 -w (gde E - 250 quality -A) complete all as spd and directed. Note: Weight shall be verified by the GE.
Demolition of Stone slabs of any description or thickness in floors, approns etc laid, bedded and pointed in any mortar complete all as spd and directed.
M&L for Sand stone slab 50mm thick in sun-shades, chajjas, shelves, cills, landings, cover stones, templates etc n. exc 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4 complete
Framed work such as grills, gratings, cooler stand etc. with ends of bars shouldered and/or riveted,or forged into spikes, framedguard bars, barred iron doors, ladders, framed balusters, walk ways, railings,framework of water tanks and similar work con- forming to Fe.290.Gde-E-165
M&L for complete removal of existing treatment of old plastered surface of wall and applying applying two coats of tractor acrylic washable distemper or equivalent over a coat of 1mm average thick wall putty and a coat of Decoprime cement primer, complete all as specified and directed.
M&L for preparation of old decorated plaster or un-plastered surfaces and providing one coat of white wash on wall including cornices, complete all as specified and directed.
Ditto all as per item No 67.00 here in before but on ceilings.
M&L for washing, rubbing down, preparing and stopping of old surfaces, removing nails,making good holes, cracks etc and applying two coat of cement base paint on walls, complete all as specified and directed.
M&L for preparation of new steel surface over 10cm width or girth & applying two coats of synthetic enamel paint of 1st quality over a coat of red oxide primer complete all as spd & directed.
M&L for second class hardwood in scantling, clean sawn timber fixed complete all as specified and directed
Demolition of cement concrete (reinforced) as in roofs, floors, beams, staircases, landing, chajjas and similar works(reinforcement cut as required to facilitate demoliition) complete all as specified and directed.
M&L for RCC 1:1.5:3 (Nominal Mix), type B 1, (using 20mm graded crushed stone aggregate) as in beams/ lintels over 1.5m span etc .complete all as specified and directed.
M&L for RCC 1:1.5:3 (Nominal Mix), type B1, (using 20mm graded crushed stone aggregate) as in roof slabs supported on walls, beams and colums in floors, roofs, landings, balconies, canopies, deck slabs and in shelves etc. complete all as specified and directed.
M&L for mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
M&L for mild steel TMT bars of 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M&L for form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, and similar work; not exceeding 200mm thick (horizontal/ sloping) etc complete all as specified.
M&L for form work to sides and soffits of floor or roof beams, beam haunchings girders, bressum-mers, lintels, chajjas and sides of bands cantilevers, shelves including supports, overhanges, etc.also splays between floors and beams etc complete all as spfd and directed.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide complete all as secified and directed.
Taking down existing water proofing treatment of any description incl PCC padding, cement plaster any thickness from roof surfaces, cleaning of roof and prepairing it for further treatment incl make good necessary dubbing out wherever required and removing rubbish from site all as directed.
M&L for PCC (1:2:4) type B-0 (using 12.5mm graded crushed stone aggregate) as in roof kerbs/ rounded or chanfered edges levelling course/ coving, bencing etc and similar works complete all as specified and directed.
M&L for screed plaster 10mm thick in CM (1:4) on fair faces of brick work or concrete surfaces incl necessary doubingout etc finished even and smooth for laying WPT without using extra cement.
Supply only Integral waterproofing compound complete.
M&L for coved fillet in PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) at junction of roof & parapet wall and other vertical surfaces 75mm radius and surface painted with a hot paving bitumen grade 30/40 conforming to IS-73 @ 0.70 Kg/Sqm over a coat of bituminous primer conforming to IS-3384 @ 0.30 Ltr Sqm complete all as specified and directed
M&L for APP modified polymeric water proofing membrane, 3mm thick having centre core not less than 100 micron high molecular high density polythylene film (HMHDPE) protected on both sides with high polymeric asphaltic mix and 20 micron HMHDPE film weight not less than 3.00Kg/Sqm applied with bonding material using blown type bitumen conforming to IS-702 grade 85/25 @1.20 Kg/Sqm over bitumen primer conforming to IS-3384 @0.40 Kg/Sqm with final coat of bonding bitumen grade 85/25 @1.20 Kg/Sqm over APP membrane with all overlaps complete all as specified and directed.
M&L for PCC 40mm thick (minimum Consolidated thickness) (1:2:4) Type B-0, (using 12.5 mm graded crushed stone aggregate) as in padding finished even and smooth without using extra cement with existing slope with V shaped grooves 6mm wide and 10mm deep @ 0.60 metre spacing both bays or part there of on top of padding and filled with mastic bitumen of (1:1) preparation complete all as specified and directed.
M&L for Preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil all as specified and directed
M&L for preparation of old painted steel surfaces of any description over 10cm width or girth & applying one coat of synthetic enamel paint of approved quality, tint to achieve glossy finish, complete all as specified and directed.
Taking down/ up old unserviceable MS water rising mains including fittings with any type of joints of size 200mm /150 mm
Taking down/ up old unserviceable foot valve 150/ 200 mm size
Taking down/ up MOV butter fly sluice valve with other accessories and refixing only with flanged ends any pattern 200 mm
Taking down/ up old unserviceable cast iron Non return valve including necessary jointing material like nuts bolts and washers, rubber gasket complete of size 150 mm
Disconnection and dismantling 60 HP Pump and Motors etc, stacking in side/ deposite in E/M Store.
Disconnection and dismantling 7.5 HP/ 5.5 KW Submersible Pump Motors set including cable starter etc, stacking in side /deposite in E/M Store
Supply and laying in trenches MS ERW 6 mm thick in new or old direction including special and all fittings (tee , union , nipple, reducer, elbow, etc) & welding work as required at site of size 200 mm bore all as specified and as directed by Engr-in-charge .
S&F, testing and commissioning cast iron Non return valve as existing type including necessary jointing material like nuts bolts and washers, rubber gasket complete of size 150 mm all as sprcified and as directed by Engr-in-charge .
Supply and fixing cast iron foot valves 200 mm size as existing type complete all as specified and as directed by Engr-in -charge .confirm IS-4038.
S&F, testing and commissioning 60 HP centrifugal Motor pump set electric driven ,capable of delivering 70 LPS at 45 mtr head comprising of horizontal split casing pump multistage CI body with impeller operating at 1480 RPM , AC 415 Volts , 50 HZ , 3- Phase , coupled with flexible coupling including as existing suitable capacity starter and PCC foundation and foundation plate with anti vibration pad and necessary joining material like nuts bolts and washers , rubber gasket complete as directed by Engr-in-charge.
S&F, testing and commissioning 7.5 HP/ 5.5 KW Mono block Submersible Pump,Horizontal type suitable for open well / under ground sump electric Driven 415 V, TP, 50 Hz, AC power supply with 40 mtr submersible cable of size 10 Sqmm 3 core.
Supply and laying in trenches MS ERW 6 mm thick in new or old direction including special and all fittings (tee , union , nipple, reducer, elbow, etc) & welding work as required at site of size 150 mm bore all as specified and as directed by Engr-in-charge .
Note for all items: All items shall be executed as specified and directed by Engr-in-charge.
SHREE BALAJI TRADING CORPORATION
SINGH ENTERPRISES
PD GUPTA AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .