| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC | L1 | Accepted-AOC lowest and reasonable | |
| 2 | L2₹14.2 L+₹2.2 L (18.3%)Rejected-Finance BLOCK NO 6 7 WING NO 3 RAHUL COMPLEX I ST BUS STAND GANESHPETH GANESHPETH NAGPUR NAGPUR MAHARASHTRA 440018 | NAGPUR | MAHARASHTRA | 440018 | L2 | Rejected-Finance not lowest | |
| 3 | L3₹15.1 L+₹3.1 L (25.7%)Rejected-Finance 58 CHANDRALOK BLDG MAYO HOSPITAL ROAD NAGPUR 440018 | NAGPUR | NAGPUR | MAHARASHTRA | 440018 | L3 | Rejected-Finance not lowest | |
| 4 | L4₹15.2 L+₹3.2 L (26.9%)Rejected-Finance B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L4 | Rejected-Finance not lowest |
Tender Value
Refer Docs
EMD Value
₹28,600
Closing Date
2 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAGPUR
OFFICE OF GARRISON ENGINEER AIR FORCE VAYUSENA NAGAR NAGPUR- 440007
REPAIR/MAINTENANCE OF COOLING APPLIANCES AT VSN, MCCF, SONEGAON, 22 P and S, AKSC NAGPUR
2021_MES_410788_2
GE/NAG/20-21/8419/65
Open Tender
Miscellaneous Works
Item Rate
180 days
GE AF NAGPUR
As per NIT
7 documents required · 7 mandatory
₹500
GE AF NAGPUR
₹28,600
26 Mar 2021
9 Feb 2021
4 Mar 2021
9 Feb 2021
2 Mar 2021
16 Feb 2021
60 days
Amount
Taking out unserviceable temp sensor and Supply and fix Temperature sensor with cold assembly 230 v AC suitbale for splittype/cassetter ac of 1.5/2 Ton cap of make RANUTROL/DANFOSS/INDFOSS complete all as specified and directed.
Taking out unserviceable and Supply and fix Air filter suitbale suitable for 1.5 ton splitAC as per sample in Engr-in-charge office complete all as specified and directed.
Taking out unserviceable and Supply and fix copper cappliary tube suitable for window /split type AC's water coolers complete all as specified and directed.
Taking out unserviceable and Supply and fix over load protector suitable for window type AC 1.5 ton capacity complete all as specified and directed.
Taking out defective capacitor and supply and fix running capacitir suitable for 1.5 ton 230 v ac split 36/40 mfd make SIEMENS/SHARHA/ASIAN complete all as specified and directed.
Taking out defective capacitor and supply and fix running capacitir suitable for 1.5/2 ton split cassette type AC 230 v ac 40/45/50/55/60 mfd of make BAJAJ/SIEMENS / SHARHA/ ASIAN complete all as specified and directed.
Taking out defective capacitor Supply and fix starting capacitor 80/100 mfd 230 V AC suitable for 1.5 TON w/type AC complete all as specified and directed. Make TESLA/SHARDA/ASIAN
Taking out defective capacitor Supply and fix running capacitor 100/120 mfd 230 V AC suitable for 1.5 TON w/type AC complete all as specified and directed. Make TESLA/SHARDA/ASIAN
Taking down unserviceable starting relay and supply and fix starting relay for 1.5 ton window type
Taking down unserviceable fan motor blade assembly & supply and fix fan motor blade assembly for split type AC 1.5/2 TR complete all as specified and directed.
Taking down unserviceable fan motor blade assembly & supply and fix fan motor blade assembly for window type AC 1.5/2 TR complete all as specified and directed.
Taking down unserviceable blower drum assembly and supply and fix new suitable for 1.5 ton capacity of split type acs for any make/model complete all as specified and directed.
Taking down unserviceable fan motor assembly & supply and fix fan motor assembly 1.5 Ton window type AC complete all as specified and directed.
Taking down unserviceable condenser fan motor assembly and supply and fix new suitable for 1.5/2 Ton split type AC complete all as specified and directed.
Taking down unserviceable remote assembly kit & supply and fix including PCB board suitbale for 1.5 TON cap window type AC of any make/model complete all as specified and directed.
Taking down unserviceable remote assembly kit and supply and fix new including PCB board suitbale for 2 TON cap split/ type AC of any make/model complete all as specified and directed.
Taking down unserviceable PVC drain pipe & supply and fix with new PVC drain pipe with clamps set of size 40 mm dia up to 2 mtrs complete all as specified and directed.
Taking down unserviceable PVC drain pipe & supply and fix with new PVC drain pipe with clamps set of size 20 mm dia up to 2 mtrs complete all as specified and directed.
Supply only cordless Remote suitbale for 1.5 Ton cap window type AC of any make / model complete all as specified and directed.
Supply only cordless Remote suitbale for 1.5/2 Ton cap split type AC of any make / model complete all as specified and directed.
Taking down unserviceable power contractor & supply and fix suitable for 1.5/2 ton cap split type AC of any make /model complete all as specified and directed.
Taking down unserviceable brass suction valve & supply & fix new suction valve 5/8" suitable for cassette /split type complete all as specified and directed.
Taking down unserviceable brass suction valve & supply & fix new suction valve 1/2" suitable for cassette /split type complete all as specified and directed.
Taking down unserviceable brass discharge valve & supply & fix new brass discharge valve 3/8" suitable for cassette /split type complete all as specified and directed.
Taking down unserviceable brass discharge valve & supply & Fix new brass discharge valve 1/4" suitable for /split type complete all as specified and directed.
Taking down unserviceable brass flare nut 5/8" supply and fix new brass flare nut 5/8" suitable for /split AC complete all as specified and directed.
Taking down unserviceable brass flare nut 1/2" supply and fix new brass flare nut 1/2" suitable for /split AC complete all as specified and directed.
Taking down unserviceable brass flare nut 1/4" supply and fix new brass flare nut 1/4" suitable for cassette /split AC complete all as specified and directed.
Supply and fix PVC rigid conduit pipe 20/25 mm dia including all accessories and necessary saddles with fixing screwa, gutties etc. complete all as specified and directed.
Supply and fix flexible U-PVC trunking of size 105x50 mm duly fixed on wall/floor all as specified and as directed
Taking down unserviceable sheet metal enclusure withearth plug socket & suply and fix sheet metal enclosure with single pole and neutral with two pin and earth plug and socket complete withone single pole mcb 20 amp complete all as specified and directed.
M&L for preparation of surface and applying with one coat of synthetic enamel paint over one coat of primer by spray painting forwindow/split Acs capacity 1.5Ton/2 ton complete all as specified and directed.
M&L for repair to body chasis including replacemetn of all corroded /rusted portion and chais and making good the same to existing location and refixing of all components complete for 1.5/2 Ton Acs including scrapping existing paint and spraying one coat of synthetic enamel paint over one coat of primer for 1.5/2 Ton ACs complete all as specified and directed.
Dismantling of 1.5/2 TR capacity of split type Acs and removing of existing indoor/ outdoor units, including MS angular frame /MS channels, copper tube , foundationframes etc, complete and closing of holes of pipe line and drain water opening and making surface goood with plastering and painting to match the existing colour of walls complete all as specified and directed.
Fixing of 1.5/2TR capacity of split type Acs indoor& outdoor units including MS chanels, modification of copper tubes including installation foundation frames of out door unit complete and provision of opening of through holes for pipe line and drain water in brick/stone masonary wall and disturbed surface making good with plastering and painting to match existing colour of walls, Note: Item obtained from the above ser No 34 shall be reused complete all as specified and directed.
M&L for fabrication of outer shell cover for windopw type air conditioning of 1.5 TR capacity and including preperation of surface and applying with two coats of synthetic enamel pait over one coat of primer by spray painting complete all as specified and directed.
Dismantling of unserviceable condensor coil complete and providing of new condensor coil of same size and quality complete suitable for window/ split type AC of capacity 1.5/ 2 Ton complete all as specified and directed. Make - LG, Usha, Voltas, Fedder Llyod
Dismantling of unserviceable knob of thermostat and providing of new knob of thermostat of same size and quality suitable for the existing window/ split type AC of capacity 1.5/ 2 Ton complete all as specified and directed. Make - LG, Usha, Voltas, Fedder Llyod
Dismantling of defective compressor sealed unit from the existing AC's foundation by removing suction/ discharge line and providing of new compressor sealed unit of same size and quality from the manufacturers of ACs or of make authorised by the manufacturers of AC's, reciprocating type and checking (company re-oriented), system with nitrogen gas pressure, testing for leakages and vaccumisation of complete system with gas recharging with R-134a gas, R -22 oil testing suitable for 1.5 Ton window / split AC capacity including testing complete of Make - LG, tecumsha, Voltas, emerson. Note :- The rate shall be inclusive of refrigerant gas.
All as per item No.42 above but, Rotary Type
Dismantling of defective compressor sealed unit from the existing AC's foundation by removing suction/ discharge line and providing of new compressor sealed unit of same size and quality from the manufacturers of ACs or of make authorised by the manufacturers of AC's, reciprocating type and checking (company re-oriented), system with nitrogen gas pressure, testing for leakages and vaccumisation of complete system with recharging with R-134a gas, R -22 oil testing suitable for 2.0 Ton window / split AC capacity including testing complete of Make - LG, tecumsha, Voltas, emerson.
All as per item No. 44 above but, Rotary Type complete all as specified and directed.
All as per item No.44 above hereinbefore but liquid line filter suitable for 2 Ton window/ split AC complete all as specified and directed.
Taking out of defective fan motor and providing new fan motor suitable for existing make of AC split / window type capacity 1/8 HP complete all as specified and directed.
All as per item No. above but for fan motor suitable for AC split / window type of capacity 1/10 HP complete all as specified and directed.
M & L of taking out existing filter and capilary by new filter and capillary of same size and quality suitable for window/ split type air conditioner 1.5/ 2 TR complete all as specified and directed.
Dismantling of existing unserviceable blower motor and providing of new blower motor double ended shaft type of capacity 1/ 6 HP single phase of 230 volts AC supply suitable for 1.5 Ton capacity split / window type air conditioner complete all as specified and directed. Make - LG, Voltas, BlueStar.
Dismantling of existing unserviceable blower motor and providing of new blower motor double ended shaft type of capacity single phase of 230 volts AC supply suitable for 2 Ton capacity split / window type air conditioner complete all as specified and directed. Make - LG, Voltas,Blue star.
Taking down of unserviceable PCB (permanent circuit board) and providing new PCB for AC of 1.5 / 2.0 Ton capacity of split/window AC complete all as specified and directed.
Taking out of unserviceable swing motor and providing new swing motor of same quality and charecteristics suitable for any make of AC 1.5 / 2.0 Ton split / window type complete all as specified and directed.
Dismantling old and providing new copper tubes of size 1/4 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 1/2 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 3/8 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
Dismantling old and providing new copper tubes of size 5/8 inch for suction line including rubber tube insulations of same size for fixing AC complete all as specified and directed.
M & L for checking of gas leakage and supply and charging of gas, including vacummising , cutting, brazing after filling again and checking of gas leakage after gas charging for the following instruments :- Note : Make of gas : R-134 a. Contractor shall be ensure that gas charging to be measured as Job and if there is any leakage during the contract period, then the same will be fullfilled by the contractor without any extra cost. Note: tools and plants, gas cylinder shall be issued by MES.
(a) Split AC (2 Ton),
(b) Split AC (1.5 Ton)
(c) Window AC 1.5 Ton
Supply only Refrigerant (R -22) suitable for window AC. Note: Empty cylinder will be issued by the department.
Supply only Refrigerant (R -134a/410A) suitable for split/window AC. Note: Empty cylinder will be issued by the department.
Supply & Fixing pvc insulated 1100v grade of size 2.5 sqmm, 3 core pvc round sheathed insulated flexible FR copper cable complete all as specified and directed.
Supply & Fixing pvc insulated 1100v grade of size 4 sqmm, 3 core pvc round sheathed insulated flexible FR copper cable complete all as specified and directed.
S & F rubber insulation suitable for existing copper pipe from indoor unit to outdoor unit of split AC 1.5/2 ton capacity and as directed.
Taking out old unserviceable split AC stand of outdoor unit and supply & fixing new stand suitable for 1.5/2 ton including necessary fixing arrangement complete all as specified and directed.
M&L for sub main wiring (concealed) complete with two single core 6sq mm FR PVC insulated unsheathed stranded copper conductor cable drawn through in and including 25 mm dia rigid non-metallic PVC conduit and fittings including 6 sq mm FR PVC insulated unsheathed stranded copper earth cable connected to common earth dolly complete and including cutting chasing using machine cutting and making good the disturbed surface complete all as specified and directed.
Material and labour of plywood of 6mm thickness,grade BWR,type BB , fixed with screws to timber frame work in room windows suitable for window type AC with grill face opening complete all as specified and directed.
Taking down U/S front grill cover and providing of new front grill cover of existing shape and characteristics suitable for 1.5 window/split type air conditioning complete all as specified and directed.
Supply and install Voltage stablizer automatic operation single phase naturally air cooled indoor type & designed for input variation between 170 Volt to 250 Volt with output voltage stablized at 230 Volt with accuracy of (+/-)2.5 percent of capacity 4KVA complete all as specified and directed. Make:V guard ,Steady Volt,Microtek
M & L for painting to the following capacity of water cooler type by scraping out the old paint, preparing the surfaces and spray painting with duco paint one coat over one coat of approved primer to external surfaces and one coat of anticorrosive black painting to compressor, condensor, stand bottom portion etc and writing SM No & MES No as per standard letter size all as specified and as directed. (a) Water Cooler 40/80 Ltrs capacity
Taking out of defective fan motor and providing new fan motor of same quality and characteristics suitable to any make of water cooler type capacity 1/8 HP complete all as specified and directed.
Dismantling of unserviceable thermostate and providing of new thermostate of same size and water cooler quality complete suitable of Make - LG, Usha, Voltas, Fedder Llyod
M & L for checking of gas leakage and supply and charging of gas, including vacummising , cutting, brazing after filling again and checking of gas leakage after gas charging for the following instruments :- Note : Make of gas : R-134 a. Contractor shall be ensure that gas charging to be measured as Job and if there is any leakage during the contract period, then the same will be fullfilled by the contractor without any extra cost. No tools and plants, gas cylinder shall be issued by MES.
(a) Refrigerator (165 Ltrs to 310 Ltrs)
(b) Drinking Water Cooler 40/80 Ltrs
Dismantling of existing unserviceable Float valve of size 15mm and providing new one of same size,quality and characteristics suitable for Water Cooler complete all as specified and directed.
Dismantling of existing unserviceable magnetic door lining and providing new magnetic door lining suitable for refrigerator of 165/ 300 iltres capacity complete all as specified and directed.
Dismantling of defective compressor sealed unit of refrigerator from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 including connection suction/ discharge line complete of 165/180 /310Ltrs capacity refrigerator complete all as specified and directed.
Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 including connection suction/ discharge line complete of150/120Ltrs capacity water cooler complete all as specified and directed.
Dismantling of defective compressor sealed unit of water cooler from existing foundation by removing suction/ discharge line and providing new approved compressor of equal capacity given below (company re-oriented) flushing complete system with nitrogen gas pressure testing for leakages, vaccumisation of complete system and gas charging with F - 134 including connection suction/ discharge line complete of 40/80/60Ltrs capacity water cooler complete all as specified and directed.
Taking down of unserviceable condensor coil and providing new condensor coil of same size and quality for water cooler capacity upto 120 LPH complete all as specified and directed.
Taking out of defective water taps of water cooler and supply and fix new water taps chromium coated 15 mm dia push type of same quality and characteristics suitable to existing water cooler complete all as specified and directed. Make Prayag / jaquar
Taking out of unserviceable PVC pipe of 20 mm dia and providing new PVC flexible pipe of 15 dia and of same quality for water circulation to air cooler all as specified and as directed.
Supply and fixing 20 mm dia steel water tubing medium grade galvanised with all fittings and fixed complete to wall ,ceiling or laid in floors complete all as specified and as directed
S&F stop valves cast copper alloys screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipes of size 20 mm dia complete all as specified and directed.
M & L for complete maintenance and repairs of refrigerator of capacity 165 to 310 ltrs including servicing cleaning of refrigerator internal portion checking of compressor, condenser and replacement of overload relay, thermostat, capacitor, wiring,veg tray,chiller tray,strainer,freezer door and timer etc and testing complete all as directed. Notes of Item No. 1 to 4) do not paid separately. (i) Rates includes servicing of unit for one time and will be considered as one job. (ii) Rates are including for Spares required for replacement which is mentioned in servicing item no. (1 to 4) do not paid separately. (iii) Servicing shall be carried out in the presence of Engr-in-Charge or his representative. Necessary service report(complaint slip) is to be signed by the rep. of AGE E/M. (iv) Old spare parts retrived after replacement will be the property of the cotractor under schedule of credit and shall be removed by the contractor outside at his own cost.
Taking out unserviceable and Supply and fix over load protector suitable for water cooler of 40/80/60/120/150 ltr cap of water cooler complete all as specified and directed. Make : Shriram/Ranutrol
Taking out unserviceable and Supply and fix fan motor capacitor suitable for water cooler of 40/80/60/120/150 ltr cap of water cooler complete all as specified and directed.
Taking out defective capacitor and supply and fix running capacitir suitable forof 40/80/60/120/150 ltr cap of water cooler complete all as specified and directed. Make : Shriram/Ranutrol
Taking down unserviceable starting relay and supply and fix starting relay for water cooler cap 40/80/60/120/150 ltrs complete all as specified and directed.
Taking down unserviceable wiring kit and supply and fix wiring kit for water cooler 2.5/4 sqmm copper wire full set including clips complete all as specified and directed.
Taking down unserviceable fan motor blade & supply and fix fan motor blade for water cooler cap 40/80/60/120/150 ltrs complete all as specified and directed.
Taking down unserviceable insulation & supply and fix thermal insulation with fiber glass 15 mm thick for water cooler of any capacity complete all as specified and directed.
Taking down unserviceable push cock & supply and fix new push cock of brass chromium plated suitable for water cooler any make/model complete all as specified and directed. Make Prayaj/Jaquor
Taking down unserviceable float valve with all accessories of 15 mm & supply and fix float valve 15 mm (PVC) suitbale for any capacity of water coolers complete all as specified and directed.
Taking down unserviceable Water cooler tray 80/40,80/120 ltr and supply and fix new water waste tary stainless lteel material in existing water cooler all as specified and directed.
Taking out u/s and supply and fix timer for suitbale to AC split type t21.5 tr having operating range 0 to 100 degree c c, connector 30 amp heavy duty, time can be set 01 hr to 10 hrs, fully programmable , 12 month warranty period , supply voltage 230 v ac, 50 hz +-/-15% all as specified and as directed
M&L for preparation of surface and applying with one coat of synthetic enamel paint over one coat of primer by spray painting for water cooler of any capacity complete all as specified and directed.
Taking down U/s and suuply and fix 16 amp switch socket combination 3 pin 16 Amp flush type all as specified and as directed
Supply and provide in holes of POP (Plaster of peris) alabaster plaster (450 Gms ) very high strength , fast setting , dries fast , snow white colour , creamy consistency , compressive strength after 1 hrs : 150kg/cm2 complete all as specified and directed.
Supply only self adhesive PVC Electrical insulation tape size of 1.8 cmx6.5mx0.125mm) thick all as directed
Advance Refrigeration Engineering Pvt. Ltd.
Paragon Electrotechnics
Shri Sai Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .