16 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
The work experience certificate shall be issued by a Railway officer or Bill passing Officer in Railways and Bill passing Officer /Executive In-Charge of work in other Govt. / Govt. bodies / PSUs. The certificate should bear the signature and seal of the Issuing Officer, Name of the department etc,. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final / last bill paid by company in support of above work experience certificate. (Note: Mandatory for whom it is applicable).
56 conditions · 11 needing a document upload
The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. . Necessary documents to this effect as applicable,
Electrical License as per tender conditions.
In case of other than company/proprietary firm , annexure V (A) shall also be submitted by each member of a partnership firm/ Joint Venture(JV)/Hindu United Family (HUF)/ Limited liability partnership(LLP) etc., as the case maybe. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document
Power of attorney duly stamped and authenticated by a Notary Public or by Magistrate as per Tender conditions.
The tenderers are advised to download and carefully read the Tender Document attached with this Notice Inviting tender.
Tenderers are advised to submit all the documents required to be uploaded by them in Kannada/Hindi/English. Documents uploaded in any other language shall be translated to Kannada/Hindi/English and attested copy may be uploaded for better appreciation of the tender.
Mandatory documents that are to be uploaded without which the bid will be summarily rejected are mentioned in Chapter II of the Tender Document attached with this Notice Inviting Tender
CORRIGENDUM NOTICE ON IREPS: Railway may modify the tender document by issuing online corrigendum through "www.ireps.gov.in" 15 days prior to the tender closing date. For the purpose of CORRIGENDUM in the tender, NIT period is split as under: (a) ADVERTISEMENT PERIOD: The time during which all information pertaining to tender shall be available but offers cannot be submitted (b) OFFER SUBMISSION PERIOD: 15 days prior to closing of tender, during which tenderers can submit their offer
The tenderers are advised to carefully read this tender Document (Chapter I to IV) in conjunction with Indian Railways Standard General Conditions of Contract- April 2022 with latest amendments and correction slips before participating in this Tender.
The rates quoted for the relevant supply items of work shall include the cost of materials and their accessories. Similarly, for fixing/installation/erection/ Testing and Commissioning item of work shall include the cost of labour, together with the cost of providing the necessary tools and tackles etc., so as to ensure that the work carried out forms a complete supply, installation,Testing, commissioning of item work to the satisfaction of the Engineer-in-charge.
The prices quoted shall be net including all taxes and duties etc.
Documents to be Submitted Along with Tender (i)The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / HUF etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN details along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case maybe. (ii)Following documents shall be submitted by the tenderer: (a)Sole Proprietorship Firm:
Following documents shall be submitted by the tenderer: if HUF: (i) A copy of notarized affidavit on Stamp Paper declaring that he who is submitting the tender on behalf of HUF is in the position of 'Karta' of Hindu Undivided Family (HUF) and he has the authority, power and consent given by other members to act on behalf of HUF.
Following documents shall be submitted by the tenderer: if Company registered under Companies Act2013: (i) The copies of MOA (Memorandum of Association) / AOA (Articles of Association) of the company (ii) A copy of Certificate of Incorporation (iii) A copy of Authorization/Power of Attorney issued by the Company (backed by the resolution of Board of Directors) in favour of the individual to sign the tender on behalf of the company and create liability against the company.
Following documents shall be submitted by the tenderer: if LLP (Limited Liability Partnership): (i) A copy of LLP Agreement (ii) A copy of Certificate of Incorporation (iii) A copy of Power of Attorney/Authorization issued by the LLP in favour of the individual to sign the tender on behalf of the LLP and create liability against the LLP. (iv) An undertaking by all partners of the LLP that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP or JV in which they were / are partners/members. concealment / wrong information in regard to above shall make the contract liable for determination under Clause 62 of the Standard General Conditions of Contract.
Following documents shall be submitted by the tenderer: if Registered Society & Registered Trust: The tenderer shall submit: (i) A copy of Certificate of Registration (ii) A copy of Memorandum of Association of Society/Trust Deed (iii) A copy of Power of Attorney in favour of the individual to sign the tender documents and create liability against the Society/Trust. (iv) A copy of Rules & Regulations of the Society.
The following documents shall be submitted by the partnership firm, with the tender: (i) A notarized copy of the Partnership Deed or a copy of the Partnership deed registered with the Registrar. (ii) A notarized or registered copy of Power of Attorney in favour of the individual to tender for the work, sign the agreement etc. and create liability against the firm. (iii) An undertaking by all partners of the partnership firm that they are not blacklisted or debarred by Railways or any other Ministry / Department of the Govt. of India from participation in tenders / contracts as on the date of submission of bids, either in their individual capacity or in any firm/LLP in which they were / are partners/members. Any Concealment / wrong information in regard to above shall make the bid ineligible or the contract shall be determined under Clause 62 of the Standard General Conditions of Contract.
The tenderers are advised to upload all required documents mentioned in this Notice Inviting Tender as well as in the Tender Document (Tender forms)(Chapter I to IV) along with the bid.
The schedule given in this NIT shall be read in conjunction with technical specifications/ explanatory notes and drawings given in the Tender document attached with this Tender
Upload duly filled & signed copy of "NEFT Declaration form". (please download the format from attached documents)
Partnership Deeds, Power Of Attorney Etc.: The tenderer shall clearly specify whether the tender is submitted on his/her own or on behalf of a partnership concern. If the tender is submitted on behalf of a partnership concern, he/she should upload the certified copy of partnership deed along with the tender and authorization to sign the tender documents on behalf of partnership firm. The Railway will not be bound by any power of attorney granted by the tenderer or by changes in the composition of the firm made subsequent to the execution of the contract. It may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the contractor. Note: Mandatory only for whom it is applicable.
The tenderer whether sole proprietor, a limited company or a partnership firm if they want to act through agent or individual partner s should submit along with the tender , a power of attorney duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/she/they be partner(s) of the firm or any other person specifically authorizing him/her/them to submit the tender and other tender related activities till completion of the work including signing No Claim Certificate and refer all or any disputes to arbitration. Note: Mandatory only for whom it is applicable.
The tenderer whether sole proprietor, a limited company or a partnership firm if they want to act through agent or individual partner s shall submit a power of attorney at a later stage duly stamped and authenticated by a Notary Public or by Magistrate in favour of the specific person whether he/they be partner s of the firm or any other person specifically authorizing him/them to sign the agreement, witness measurements, sign measurement books, to sign contract correspondence, signing the bills etc. the GPA shall be accepted after obtaining Legal advise from LAW branch/ Hubballi division. Note: Mandatory only for whom it is applicable.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Upload the CLEAR COPY of GST Registration particulars
SW-1: Electrical arrangements to Augmentation of Running Room at Toranagallu (80 beds).SW-2: Electrical Arrangements for the "Proposed construction of New Crew Booking Lobby atToranagallu.
HE-06-2026-27SL01
HE-06-2026-27SL01
Open
Works - General
6 Months
Dharwad, Karnataka
₹0
₹1.3 L
22 Aug 2026
31 Jul 2026
8 Aug 2026
232 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 50,71,516.58 | ||
| — | 180.00 | — | — | ||
| Excavation in trenches in any kind of soil of required width and laying of LT UG cables, including excavation for joints, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m . | — | — | — | 27,165.6 | |
| — | 350.00 | — | — | ||
| Supply of high density polyethylene pipe (HDPE pipe) of size 110 mm (nominal bore) category of PE-80, PN-6 along with accessories (T joint / straight coupler etc.), ISI marked and drawing LT cables all as per specification | — | — | — | 1,16,655 | |
| — | 350.00 | — | — | ||
| Laying of high density polyethylene pipe (HDPE pipe) of size 110 mm (nominal bore) category of PE-80, PN-6along with accessories (T joint / straight coupler etc.), ISI marked and drawing LT cables all as per specification | — | — | — | 12,960.5 | |
| — | 250.00 | — | — | ||
| Supply of high density polyethylene pipe (HDPE pipe) of size 50 mm (nominal bore) category of PE-80, PN-6along with accessories (T joint / straight coupler etc.), ISI marked and drawing LT cables all as per specification | — | — | — | 13,742.5 | |
| — | 250.00 | — | — | ||
| Laying of high density polyethylene pipe (HDPE pipe) of size 50 mm (nominal bore) category of PE-80, PN-6along with accessories (T joint / straight coupler etc.), ISI marked and drawing LT cables all as per specification | — | — | — | 1,525 | |
| — | 500.00 | — | — | ||
| Transportation, Laying, testing and commissioning of LTUG cable 4cx50/ 4cx35 / 4cx25 / 4cx16 Sqmm as per specification. Note:- LT UG cable will be issued by Railways. The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Costs of these provisions are deemed to be included in the quoted rates. | — | — | — | 8,650 | |
| — | 700.00 | — | — | ||
| Transportation, Laying, testing and commissioning of LTUG 4cx95/ 4C x 120 sqmm as per specification. Note:- LT UG cable will be issued by Railways. The contractor will be responsible for collection of cables from the Elect Maintenance / Works Depot including loading, unloading, transportation and return of un-used cables back at Depot. Costs of these provisions are deemed to be included in the quoted rates. | — | — | — | 23,884 | |
| — | 4.00 | — | — | ||
| Supplying and making end termination with brass compression gland and aluminium lugs for 4 x 120 sqmm of PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade all as per detailed specification and as directed. | — | — | — | 2,840 | |
| — | 16.00 | — | — | ||
| Supplying and making end termination with brass compression gland and aluminium lugs for 16 Sqmm size, 4 core PVC insulated and PVC sheathed /XLPE aluminium conductor cable of 1.1 KV grade as specified and directed. | — | — | — | 5,856 | |
| — | 1.00 | — | — | ||
| Design, fabrication, installation, testing and commissioning of LT Control Panel, cubical, 250 A, 3phase 4 wire system, insulated copper bus bars of size50 x 10 mm, outdoor type, weather & water proof with sloppy roof, opening from both front and rear sides, separate compartments for each control gear, cable alley and provision of knock out type entry plates suitable up to400 sqmm size cables, panel made out of 14 gauge CRCA sheet, epoxy powder coated with grey matt finish, including base frame made out of 50 x 50 x 6 mm angle iron sections, embedded in PCC 1:3:6 foundation, consisting of the following switchgears and metering devices:-(i) MCCB 250 A, 4P, 50 KA Microprocessor based release - 02 No.(ii) MCCB 160 A, 4P, 36 KA, Microprocessor based release - 02 No.(iii) On load COS 4P, 400 A, 415 V, AC, 50 Hz - 01 No.(iv) MCB 63 A, 4P, 10 KA, - 06 Nos.(v) MCB 5-32A , DP, 10 KA - 06 Nos. Multi-function 3 phase meters reading V, I, W, KVA, PF, Hz etc, including CTs, pilot lamps complete all as specified and directed. | — | — | — | 2,03,679 | |
| — | 6.00 | — | — | ||
| Fabrication, supply and erection of 6 Mtrs long hot dip galvanized octagonal pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for 6 m pole in single section and single joint welded as per IS9595/IS10178AWS having dimensions bottom 130 mm, top 70 mm with 3 mm thick suitable base plate and 4 Nos foundation bolts, necessary excavation for foundation and refilling all as specified and directed (excluding PCC foundation). | — | — | — | 70,800 | |
| — | 6.00 | — | — | ||
| Supplying, and fixing of Hot dip Galvanized M.S. Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete- Single Arm Bracket with 1000 mm Standard 40/50 mm dia. | — | — | — | 10,200 | |
| — | 1.50 | — | — | ||
| Providing and making steel pole collar with cement concrete (1:3:6) with stone aggregate 20 mm nominal size in foundations of specified size and shape including form work, plastering if required, curing etc as required.(Volume of pole /pipe not to be deducted). | — | — | — | 13,251 | |
| — | 9.00 | — | — | ||
| Supplying and embedding 40 mm dia GI pipe, medium class, in pole collar / foundation (During casting) for cable entry including bending the pipe to the required shape complete as required. | — | — | — | 5,634 | |
| — | 6.00 | — | — | ||
| Supply and fixing of 50 W, LED Street light fitting as per detailed specification. | — | — | — | 10,692 | |
| — | 42.00 | — | — | ||
| Supplying and drawing 3 x 1.5 sq mm of FRLS PVC insulated copper conductor, single core cable in the existing surface/ PVC conduit as required | — | — | — | 4,368 | |
| — | 6.00 | — | — | ||
| Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with Charcoal/coke and salt as required | — | — | — | 50,106 | |
| — | 60.00 | — | — | ||
| Providing and fixing 25 mm x 5 mm G.I strip on surface or in recess for connections etc. as required. | — | — | — | 17,220 | |
| — | 2.00 | — | — | ||
| Supplying and fixing of 6 way (4 + 18), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, in recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required | — | — | — | 10,598 | |
| — | 10.00 | — | — | ||
| Supplying and fixing 12 way, Double door, single pole and neutral, sheet steel, MCB distribution board, 240 V, in recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required- | — | — | — | 28,710 | |
| — | 2.00 | — | — | ||
| Supplying and fixing 50 A to 63 A rating, 415 V, 10 kA, "C" curve, TPN/four pole miniature circuit breaker suitable for inductive load of in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 6,176 | |
| — | 2.00 | — | — | ||
| Supply and fixing 63 A, triple pole and neutral 415 V, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required | — | — | — | 7,194 | |
| — | 68.00 | — | — | ||
| Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, Double pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. | — | — | — | 47,328 | |
| — | 12.00 | — | — | ||
| Supplying and fixing 5 A to 32 A rating, 240/415 V, 10kA, Single pole miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. complete all as specified and as directed. | — | — | — | 3,420 | |
| — | 600.00 | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the size of 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering /making good the disturbed surfaces all as specified and as directed. | — | — | — | 1,60,200 | |
| — | 1500.00 | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the size of 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering /making good the disturbed surfaces all as specified and as directed. | — | — | — | 4,66,500 | |
| — | 1100.00 | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the size of 2 X 4 sq. mm + 1 X 4 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering /making good the disturbed surfaces all as specified and as directed. | — | — | — | 4,10,300 | |
| — | 600.00 | — | — | ||
| Wiring for circuit/ submain wiring along with earth wire with the size of 2 X 6 sq. mm + 1 X 6 sq. mm earth wire FRLS PVC insulated copper conductor, single core cable in recessed medium class PVC conduit including all necessary connected works such as cutting chases, drilling holes on wall / ceiling etc including plastering /making good the disturbed surfaces all as specified and as directed. | — | — | — | 2,89,200 | |
| — | 576.00 | — | — | ||
| Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm FRLS PVC insulated copper conductor single core cable etc. as required all as per detailed tender specifications. | — | — | — | 6,84,864 | |
| — | 220.00 | — | — | ||
| Supplying of 20/22 W LED Batten fitting, 240 V AC with diffuser and driver including all connected materials asper detailed specification. | — | — | — | 1,51,800 | |
| — | 50.00 | — | — | ||
| Supply of indoor type LED modular down light 25/30 W , 1 foot x 1 foot Recess/Surface mounted all as per SWR specifications. | — | — | — | 1,84,600 | |
| — | 20.00 | — | — | ||
| Supply of indoor type LED modular down light 36 W, 2 feet x 2 feet Recess/Surface mounted all as per SWR specifications. | — | — | — | 91,060 | |
| — | 40.00 | — | — | ||
| Supply of 6 W LED mirror light fitting and with driver suitable use on 230 V, 50 Hz AC supply all as per SWR specifications. | — | — | — | 54,968.8 | |
| — | 40.00 | — | — | ||
| Supply of 3 W LED Decorative night light fitting with lens and driver suitable use on 230 V, 50 Hz AC all as per SWR specifications. | — | — | — | 56,070.8 | |
| — | 80.00 | — | — | ||
| Supply of 3 W LED reading light fitting with flexible rod for up & down with switch suitable use on 230 V, 50 Hz AC supply all as per SWR specifications. | — | — | — | 68,863.2 | |
| — | 80.00 | — | — | ||
| Supply and fixing of 3 Modular LED Foot Lamp suitable use on 230 V, 50 Hz AC all as per SWR specifications. | — | — | — | 18,727.2 | |
| — | 530.00 | — | — | ||
| Fixing all types and all capacities of LED fittings indoor on the wall/ ceiling /rafters / girders using twin twisted PVC insulated wires, required Nos of round blocks and clamps. | — | — | — | 64,660 | |
| — | 100.00 | — | — | ||
| Supplying & fixing & testing of LED Strip Light IP 64warm/white, 8W/mtr including supply and fixing of of aluminium profile and all connecting accessories and labour etc. all as per detailed tender specifications. | — | — | — | 39,886 | |
| — | 50.00 | — | — | ||
| Supply of BLDC ceiling fans, working on 230 V AC, 50Hz of Sweep size1200 MM all as per detailed technicalspecification including provision of necessary down rodsof required length, canopies, clamps etc all as directed | — | — | — | 1,33,850 | |
| — | 50.00 | — | — | ||
| Fixing of BLDC ceiling fans, working on 230 V AC, 50 Hz of Sweep size1200 MM all as per detailed technical specification including provision of necessary down rods of required length, canopies, clamps etc all as directed. | — | — | — | 15,750 | |
| — | 45.00 | — | — | ||
| Supply of single phase modular type BLDC Exhaust fan 200 mm sweep complete with all accessories etc | — | — | — | 83,065.5 | |
| — | 45.00 | — | — | ||
| Fixing of single phase modular type BLDC Exhaust fan 200 mm sweep complete with all accessories etc complete all as per detailed tender specifications. | — | — | — | 9,229.5 | |
| — | 40.00 | — | — | ||
| Supply and fixing of Electronics bulbul bell bird chime Call bell similar to anchor model No.8432 including provision 2 Module Gl box with cover plate with frame including connection fixing of call bell with all connected materials and works. | — | — | — | 11,264 | |
| — | 6.00 | — | — | ||
| Supply of 72 W, LED Street light fitting on walls / pillars including all necessary fixing arrangements such as clamps, nuts, bolts etc; as per site requirement and as per detailed specification. | — | — | — | 10,368 | |
| — | 6.00 | — | — | ||
| Supplying and Fixing of 25 mm dia class A GI pipe bracket up to 2 mtrs long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. | — | — | — | 5,868 | |
| — | 6.00 | — | — | ||
| Fixing LED floodlight fitting/Street light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | — | — | — | 972 | |
| — | 576.00 | — | — | ||
| Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. | — | — | — | 59,904 | |
| — | 45.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front in recess, including providing and fixing 25 A modular socket outlet modular socket outlet and 25 A modular MCB C curve, connections etc. as required. | — | — | — | 36,315 | |
| — | 45.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. | — | — | — | 29,655 | |
| — | 40.00 | — | — | ||
| Supplying and fixing 6 pin15/16 A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | — | — | — | 8,760 | |
| — | 40.00 | — | — | ||
| Supplying and fixing 6 pin 15/16 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | — | — | — | 7,040 | |
| — | 20.00 | — | — | ||
| Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and5/6 A modular switch, connections etc. as required. | — | — | — | 10,900 | |
| — | 100.00 | — | — | ||
| Supplying and fixing 3 pin 5/6 A modular socket outlet on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | — | — | — | 13,600 | |
| — | 100.00 | — | — | ||
| Supplying and fixing 3 pin 5/6 A modular switch on the existing modular plate & switch box including connections but excluding modular plate etc. as required. | — | — | — | 12,100 | |
| — | 42.00 | — | — | ||
| Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 Ton split/cassette type A/C. | — | — | — | 1,33,350 | |
| — | 126.00 | — | — | ||
| Supplying and installation of insulated refrigerant copper tubing of 5/8" and 3/8" with polythene foam insulation 3core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube | — | — | — | 1,95,174 | |
| — | 42.00 | — | — | ||
| Supply of voltage stabilizer suitable for 1 /1.5 Ton AC all as per detailed technical specification. | — | — | — | 86,023.56 | |
| — | 2.00 | — | — | ||
| Supplying, installation, Testing, Commissioning of 500 LPD capacity Evacuated Tube Collector (ETC) Solar Water Heating System comprising of all glass ETC tube absorber. The system shall have temperature gauges, strainer, 2 Nos. water meters, Suitable capacity cold and hot water tank, all MS structure for installation including suitable electric control panel complete with control and power wiring, necessary pluming including piping for cold and hot water line between tank and solar water system, Electric water heater elements 2 Nos x 3kW each, float valve and other valve etc. as required and all as per detailed tender specifications. | — | — | — | 1,81,252 | |
| — | 42.00 | — | — | ||
| Supply of Electric Water heater 25 Ltrs Cap Stationary type ( 5 Star ), 2 KW Closed / Vented type Geyser with insulated copper inner tank and all connected materials and works all as per detailed tender specifications. | — | — | — | 4,30,164 | |
| — | 42.00 | — | — | ||
| Erection charges for fixing a 25 litres capacity wall mounting electric geysers using bolts, flat at one end nut and washers at the other end for through bolts and nut sand washers with 150x450x600mm back plate and wiring complete with 15 A 3 pin top. | — | — | — | 27,888 | |
| — | 42.00 | — | — | ||
| Supply and fixing of plastic 16A 30mA PRCD Plug top Equipped with a Safety Shutter Socket Along with An Auto Trip Feature Which Shuts Off, if Detects Any Current Leakage, Backup Protection for Overload 6IEC:61540, Similar to Havells B07CRHZSN2 (Hav PRCD Life Plug 30) Accepted Brand / Make : SALZER. | — | — | — | 26,985.42 | |
| — | 40.00 | — | — | ||
| Supplying and fixing 32A security and energy saving DP switch with key tag suitable to operate on 230 V, 50HzAC supply & completely wired on existing box. | — | — | — | 25,840 | |
| — | 1.00 | — | — | ||
| Supply and provision of Water cooler (Non CFC Refrigerant) Energy Efficient, Compressor, 80 Ltrs. /Hr cooling Cap, Type - storage Cap. 150 Ltrs. Rate of Max. Energy consumption Watts-100, with all connected materials and works all as per detailed tender specifications. | — | — | — | 58,000 | |
| — | 2.00 | — | — | ||
| Supply & fixing LED, 230 V AC, 20 W pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs50000 hr Compatible for pole mounting with outer dia of40 mm to 65 mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hzapplication. Compliance to IS 10322/1 EC 60598 all as per detailed SWR specifications. | — | — | — | 13,844 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Advancecorrectionslip1to11.pdf
ATTACHMENT
JPOforcablecuttings1.pdf
ATTACHMENT
2018_CE-I_CT_9Date04_06_2018LOCLETTEROFCREDIT.pdf
ATTACHMENT
NEFTForm.pdf
ATTACHMENT
GCC_April-2022_2022_CE-I_CT_GCC-2022_POLICY_27.04.22_.pdf
ATTACHMENT
ANNEXURE-VAFFIDAVIT.pdf
ATTACHMENT
Tenderform-Works.pdf
ATTACHMENT
DECLARATIONONRETIREDRAILWAYOFFICERS.pdf
ATTACHMENT
TENDERBOOKLET-TNGL.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .