Bhurt Wala- Construction of Primary Health Centre (PHC) at Village Bhurt Wala, Block Ellenabad, Distt. Sirsa.(XV-Fiance Commission and State Budget Head-4210)
2026_HRY_545167_1
202634AA9916 C379 4836 9A07 6A238C48DFCF2184DEV
Open Tender
Civil Works
Works
365 days
BHURT WALA
Bhurt Wala- Construction of Primary Health Centre (PHC) at Village Bhurt Wala, Block Ellenabad, Distt. Sirsa.(XV-Fiance Commission and State Budget Head-4210)
10 documents required · 10 mandatory
₹15,000
₹7.9 L
Yes
2 Sept 2026
2 Sept 2026
18 Sept 2026
2 Sept 2026
17 Sept 2026
2 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1NS items | |||||
| 1.01 | SITC of 6 Zone Fire Alarm Panel with LCD Display, ested by ERTL (N) and System Sensor, 2x16 Character Backlit LCD Display and 64/128/256 Events Logging Facility, BMS Attachment, Lamp Test Features, Complete with Integral Power Supply and Battery Charger for SMF Battery, NO/NC Contacts for Both Fire, Fault and Switches to Enable on Board Operation Make Agni | 1 | Each | - | - |
| 1.02 | SITC of Wall Mount Manual Call Point:: Manual Call Point, Front Protection Glass Cover, ABS Housing with Gang Box, 24VDC., Make Agni | 5 | Each | - | - |
| 1.03 | Supply of DC Operation, High Sound Output with Low Current Consumption, Designed for Use within Fire Alarm Systems, Security Systems and Industrial Signaling Systems, It provides an Audio Warning, Which is Suitable for Place, Which Needs Audio Indication Product SpecificationMake Agni | 5 | Each | - | - |
| 1.04 | SITC of 2 core 1.5 Sq mm Cable | 600 | Each | - | - |
| 1.05 | SITC of Photoelectric Smoke Detector. NS | 41 | Each | - | - |
| 1.06 | Supplying, installation, setting, testing and commissioning of differential type pressure switches of size 100 mm dia for pressure range upto 10Kg/cm2 for operation of filter feed pumps.( NS ITEMS ) | 3 | Each | - | - |
| 1.07 | PVC CONDUIT PIPE ONLY (SURFACE OR RECESSED) FOR ELECTRICAL POINTS 6.2. Supply and erection of PVC CONDUIT ISI marked (Medium) recessed in wall/ceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of Engineer-in-Charge of work. PVC pipe of 25 mm dia. | 600 | Metre | - | - |
| 1.08 | SITC of Micro processor based 2 wire fault tolerant, networkable type fire alarm / detection control panel ( having nos. of 2 loops to suit minimum 20% extra over the nos. of fire detectors. The panel shall be able to give location of all fire / fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON/OFF respective control module when ever any alarm is triggered. The panel shall have rectifier, loop cards, minimum 160 character L C D unit/ 5.7’’TFT to indicate Fire / Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects. The Panel Shall be sheet Steel power coated, sealed to IP30. The Panel shall have 20 Zones with individual LED Indicators, expandable to 80LED Indicators. The Panel shall have 3 Serial Ports. The panel shall have a built in power supply and battery charger along with maintenance free 24 AH,2 x 12 volt SMF lead acid batteries capable of running for a minimum of 24 hours with battery charger complete as required. And conforming to BS5839 standards and Duly Approved by EN 54/UL/VDS/ as per specifications complete in all respect up to the entire satisfaction of Engineer-in – charge of work Makes : Honeywell Morley/ Siemens cerberus/ GST. | 1 | Each | - | - |
| 1.09 | Supply Installation Testing and Commissioning of addressable multisensor detector with a combination of Optical and Thermal including mounting base, auto addressing feauture as required. Detetctor should have 2 as per NFPA 72 style 7 wiring requirements (one for incoming and one for outgoing line) for maintaining operational availability of all elements in the loop in the event of a short circuit and to meet style 7 requirements. High resistance to electromagnetic effects in accordance with EFSG agreement EFSG/F/97/005 .Detector should monitor Electromagnetic interference and report to the panel - current and average values. EMC safety for detector shall be 50 V/m. Shall be EN54/ VDs/UL certification. (Detectors without Inbuilt Isolators may be considered with an additional Isolator Module after 20 devices) Make: Honeywell Morley / Siemens Cerberus / GST | 130 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
BOQ_624727.xls
BOQ • 0.32 MB
AD0174418.pdf
Additional Documents • 1.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .