Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹24.8 L+₹1.6 L (6.74%)Rejected-Finance | L2 | Rejected-Finance L2 | |
| 3 | L3₹38.2 L+₹15.0 L (64.6%)Rejected-Finance | L3 | Rejected-Finance L3 |
Tender Value
₹28 L
EMD Value
₹56,000
Closing Date
18 Mar 2020, 6:00 pmClosed
GE(SB) Karwar
GE(SB) Karwar Naval Base Karwar
ADDITION, ALTERATION AND SPECIAL REPAIRS TO BLDG NO P-06 (JR SAILORS COOK HOUSE), ADDITION, ALTERATION TO SEWAGE LINE AT DAS BLDG AND DAS HOSTEL AND PROVN OF COVERED SHED ALONGWITH HARD STANDING FOR E-TICKETING COUNTER AT ADMIN BLDG (P-19) AT INS KAD
2020_MES_326666_1
8684/E8
Open Tender
Civil Works
Item Rate
180 days
GE(SB) Karwar Naval Base Karwar
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Yes
₹56,000
Yes
4 Apr 2020
19 Feb 2020
21 Mar 2020
19 Feb 2020
18 Mar 2020
4 Mar 2020
Amount
Excavating in trenches not exc 1.5 m wide and not exc 1.5 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches exc 1.5 m wide and not exc 3.0 m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Demolition of precast concrete block walling built in cement mortar and removal of debris ouside the MD land complete all as specified and directed.
Demolition and breaking up drain pipes 150 mm dia (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris ouside the MD land complete all as specified and directed.
M & L for reinforced concrete pipes, 150 mm dia, class NP2, laid and jointed complete with collars complete all as specified and directed.
M & L for PCC 1:3:6 type C-2 (using 40 mm graded stone aggregate) for bed to drain pipe 150 mm bore including packing and haunching against the sides of pipes after they are laid and tested complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed.
Removing excavated soil not exc 50 m and deposting where directed at a level not exc 1.5 m above the starting point complete all as specified and directed by Engineer-in-Charge.
M & L for providing precast cement concrete solid building blocks masonry exc 10 cm width, type C5,1:3:6 (20 mm graded aggregate) set in cement mortar 1:6 complete all as specified and directed.
M & L for rendering 15 mm thick plaster in CM 1:4 in two coats (10 mm thick backing coat + 5 mm thick finishing coat) on concrete surfaces of walls finished even and smooth without using extra cement including mixing of integral water proofing compound in 5 mm thick finishing coat complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls of any description including and applying two coat of cement based paint over a coat of white wash complete all as specified and directed.
M & L for providing cement concrete, type D-2, 1:4:8 (using 40 mm graded aggregate) as in in foundations, filling and mass-concrete complete all as specified and directed.
M & L for providing cement concrete type B1, 1:2:4 (20 mm graded aggregate) as in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed.
M & L for precast reinforeced cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in cover slabs for manholes etc. shelves and similar articles with plain faces and set in CM 1:4 including necessary formwork complete all as specified and directed.
M & L for Mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F cast iron work grade FG 150, unmachined, in brackets, gully traps, gratings, railing, frames, manhole covers, fire and soot doors, dampers, stop valve boxes, gate stops, parts of ranges, balusters and similar articles exceeding 5 Kg complete all as specified and directed.
M & L for cutting the road i.e. black topping, WBM, soiling approx width of cutting 1.00 m and making good by providing cement concrete, type B-2, 1:2:4 (using 40 mm graded aggregate) after laying sewage pipe line complete all as specified and directed.
Dismantling of single layer Mangalore pattern or similar tiles in roofing all as specified and directed.
M & L for roof tiles, Mangalore pattern class 'AA', interlocking at side joints, laid dry complete all as specified and directed.
Demolition of cement concrete of any description and any position all as specified and directed.
M & L for Plain cement conrete (1:2:4 ) type B-0 using 12.5 mm graded aggregate as in coping, hold fast, cills, steps, water troughs and the like including weathering, slightly rounded or chamfered angles and throating etc. complete all as specified and directed
M & L for Plain cement concrete (1:3:6 ) type C-0 using 12.5 mm graded aggregate as in roof kerbs or mud stops rounded or chamfered edges complete all as specified and directed
M & L for applying two coats of water proofing coating system by applying shalicryl-215 of STP Ltd/ Rain coat 601 of DR fixit/ Barrier coat of Araldite over a coat of respective primer including preparation of plastered surface by complete removal of existing treatment including filling of crack with respective crack filler all as per manufacturer's instructions complete all as specified and directed .
Removing existing water proofing treatment of any description from roof slabs, cleaning the surface using wire brushes etc, roughening the concrete surfaces, picking, sweeping clean and washing down with water to remove dust etc. and brushing neat cement slurry with 3.00 kg of cement per Sqm (Where PCC padding is to be provided) complete all as specified and directed (for tank portion with side wall).
M & L for PCC (1:2:4) type B-0, 25 mm thick (using 12.5 mm graded crushed stone aggregate) as in roof paddding, complete all as specified and as directed.
M & L for bedding layer in CM (1:4) 10 mm thick on concrete surfaces mixed with WPC @ 2% by weight of cement finished the surfaces fair and even, complete all as specified and as directed. NOTE: WPC shall be measured and paid separately under respective item.
M & L for preparing the roof surfaces with clean, dust free on dry surfaces for water proofing treatment as follows: (a) Providing minimum slope using cement mortar (1:3). Cleaning the surface eliminating sharp edges. (b) Applying one coat of water based bitumen emulsion primer @ 0.30 Kg/Sqm on the surface to be water proofed. (c) Applying a coat of hot blown bitumen 85/25 @ 1.20 Kg/Sqm on the primed surface. (d) Laying 4mm thick polymetric membrane on the hot bitumen applied surface. With overlaps maintained at 10 cms and are completely thermo-fused by flame torch. (e) Finishing with a coat of bituminous aluminum primer @ 100 grams/Sqm complete all as specified in application manual of the company and as directed.
Supply only integral water proofing compound .
Taking down cement plaster on brick or stone walls etc, including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed by Engr-in-Charge.
M & L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:6 finished fair and even complete all as specified and as directed.
M & L for rendering 20 mm thick (externally) in CM 1:4 in two layers each of 12 mm +8 mm thick on brick or concrete surfaces including finished surfaces even and fair, using 3% WPC by weight of cement complete all as specified and directed.
M & L for applying one coat of acrylic washable distemper on old decorated surfaces of walls including preparation of surfaces all as specified and directed.
All as per item No 32.00 above but on ceiling surfaces.
M & L for preparing of old plastered surface of walls and applying one coat of weather resistant paint (Apex/Weather coat) painting (approved shade) over complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and removing all the rubbish as directed by Engineer-in-charge complete all as specified and directed.
M & L for coloured non-skid cermaic tiles 7 to 8 mm thick (square/ rectanglar) area of each tile exceeding 0.11 Sqm but not exc 0.18 sqm, in each floor etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for coloured non-skid Ceramic tiles 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M & L for coloured glazed ceramic tiles 300 x 200 x 7 mm thick, on vertical surfaces such as skirting, dado and risers to steps etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10 mm thick rendering in CM 1:4 on brick wall complete all as specified and directed.
Demolition of stone slabs and tiles of any description and thickness in floors, aprons etc laid bedded and pointed in any mortar complete all as specified and directed.
M & L for screed bed or bedding layer 20 mm thick in cement mortar 1:6 to receive topping layer such as tiling etc complete all as specified and directed.
M & L for machine cut kota stone slab flooring 20-25 mm thick, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed. NOTE: Size of kota stone shall not be less than 60 x 60 cm.
S & F health faucet stainless steel cleaning system with connect pipe and hook (Chorme). MAKE: Hindware Cat Part No. 511677 or equivalent as approved by GE.
Taking up or down 15 mm bore steel tubing and connections, removal to store as directed by Engr-in-Charge.
Taking up or down 20 mm bore steel tubing and connections, or removal to store as directed by Engr-in-Charge.
M & L for cutting channels, grooves or rebates not exc 15 cm girth, and trimming surface of with or without reinforcement as directed by Engr-in-Charge.
S & F 15 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors all as spcified and as directed.
S & F 20 mm dia GI pipe medium grade with all fittings and fixed complete to walls or laid in floors all as spcified and as directed.
S & F in repairs 15 mm bore bib taps, CP cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed.
S & F in repairs concussive push button taps of cast copper alloy, screwed for iron pipe and fixed all as specified and directed.
S & F in repairs Vitreous china ware wash hand basin, white, flat back, size 550 x 400 mm including cutting for and pinning ends of brackets or erecting stand complete all as specified and directed.
S & F in repairs 10 Litres, PVC, valveless, syphonic action type, flushing cistern, high level, white inlet, ball valve, float, chain and pull, and brackets including PTMT PVC connection 600 mm long complete all as specified and as directed by Engr-in-Charge..
S & F in repairs stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy with crutch or butterfuly handle and screwed both ends for iron pipe or for unions complete all as specified and directed.
S & F in repairs chromium plated shower roses 125 mm size with swivel joints, any size, including fixing to steel pipe or union complete all as specified and as directed by Engr-in-Charge.
S & F in repair chromium plated tubular towel rail, 20 mm dia, D type, 60 cm long between flange all as specified and directed.
Dismantling structural steel work as in doors, gate but excluding framed truss etc all as specified and as directed by Engr-in-Charge.
Cutting opening in cement concrete walls (any description) for door, window and other openings (with or without reveals) or enlarging existing openings, including trimming surfaces to receive rendering etc. complete all as specified and as directed by Engr-in-Charge.
M & L for steel rolling shutters, 1.25 mm thick, without ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer, erected in position as indicated, complete push pull or manual type all as specified and as directed by Engr-in-Charge.
M & L for applying two coats of synthetic enamel paint on steel surfaces of any description, over 10 cm in width or girth not otherwise described complete all as specified and as directed by Engr-in-Charge.
M & L for chequered cement concrete tiles 20 cm x 20 cm x 25 mm thick, set, jointed and pointed in near cement slurry in floors with grey cement and pigment complete all as specified and directed
M & L for providing cement concrete, 75 mm thick, type D-2, 1:4:8 (using 40 mm graded aggregate) as in sub base or sub floor etc. all as specified and directed.
M & L for hardcore of gauge not exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls of any description including and applying two coats of weather proof exterior emulsion paint and over a coat of primer complete all as specified and directed.
M & L moorum/ red bajri filling in floors or pavings, laid in layers not exc.15 cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L steel work in tubular trusses, purlins, rafter etc. including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS1161-1979 grade St-240 all as specified and as directed.
M & L pre-painted galvalume aluminium zinc coated GI based corrugated steel sheet 0.5 mm thick of any colour having tensile strength of 550 MPa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and as directed by Engr-in-Charge.
ABDUL RAHIM
M/S KVG CONSTRUCTIONS
Bidder Name
ABDUL RAHIM
Ms V. S. NAYAK
M/S KVG CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .