| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹2.0 LAccepted-Finance | ₹2.0 L | 1 | Accepted-Finance Found in order |
| 2 | 2₹2.1 LAccepted-Finance | ₹2.1 L | 2 | Accepted-Finance Found in order |
| 3 | 3₹2.4 LAccepted-Finance | ₹2.4 L | 3 | Accepted-Finance Found in order |
Tender Value
Refer Docs
EMD Value
₹3,000
Closing Date
8 Jun 2021, 9:00 amClosed
EXECUTIVE ENGINEER
220 KV Sub Station Nawada Aonla Road Budaun
Regular Operation Checking Servicing And Minor Maintenance of Mulsifire System AND Hydrant System Installed at 220KV Substation Budaun under ETD Budaun on Daily basis and as per Requirement alongwith other associated Works during the Period of 10 M
2021_UPTCL_586637_2
T03
Open Tender
Plant Protection Input/Equipment Works
360 days
ETD Budaun
Please refer Tender documents.
2 documents required · 2 mandatory
₹236
EXECUTIVE ENGINEER
₹3,000
Yes
9 Jun 2021
2 Jun 2021
8 Jun 2021
2 Jun 2021
8 Jun 2021
2 Jun 2021
2 Jun 2021 - 8 Jun 2021
Amount
Regular Operation, Checking, Servicing & Minor Maintenance of Mulsifire System & Hydrant System Installed at 220KV Sub Station Budaun on Daily basis and as per Requirement alongwith other associated Works during the Period of 10 Months w.e.f. 01.06.2021 to 31.03.2022,with all Cost of Men, Misc. Consumables, T&Ps etc. Required for Satisfactory Completion of the Work as per Technical Specifications and Direction of the Supervising Engineer, as per Details below : Regular Operation, Checking, Servicing & Minor Maintenance of Mulsifire System installed on 2 No. 200MVA 220/132KV Transformers at the Sub Station on Daily basis and as per Requirement. The Work includes Regular Checking & Arresting of Leakage of Water, if any; Changing of Gland Rope; Maintaining Proper Level of Water in Tank; Keeping Constant Watch on Frequency of Running of Water Jockey Pump, Smooth Running of Main Pump, Self Starting System, Condition of Charger so as to Keep Battery Healthy with its Required Maintenance; Servicing of Deludge Valve, Foot Valve, Gate Valve, Sluice Valve etc.; Replacement & Cleaning of Defective Nozzles and Replacement of Quartz Bulb that shall be Provided by the Department, as per Requirement; Recording all Parameters during Operation of the Mulsifire System in the Register. (1 Job per Month)
Regular Operation, Checking, Servicing & Minor Maintenance of Hydrant System installed for Protection from Fire Hazards to the various Equipments in Switchyard at the Sub Station on Daily basis and as per Requirement. The Work includes Regular Checking & Arresting of Leakage of Water, if any; Changing of Gland Rope; Maintaining Proper Level of Water in Tank; Keeping Constant Watch on Frequency of Running of Water Jockey Pump, Smooth Running of Main Pump, Self Starting System, Condition of Charger, so as to Keep Battery Healthy with its Required Maintenance; Servicing of Foot Valve, Gate Valve, Sluice Valve etc.; Checking of Condition of Hydrant Posts, associated Valves, Delivery Hose Coupling (Male & Female), Fire Hose Pipe etc. including its Replacement, if Required and that shall be Provided by the Department; Recording all Parameters during Operation of the Hydrant System in the Register. (1 Job per Month)
Complete Cleaning of the Mulsifire Under Ground Water Storage Tank by Removing Mud, Fungi, Elgi etc. The Work includes Painting the Surface / Walls of the Under Ground Water Tank with Rust Proof & Fungus / Elgi Proof Paint.
Bi-Monthly Regular operation and minor maintenance of Diesel Generator Set (Kirlosker Engines make) including weekly checking its operation, cleaning, checking Battery Voltage and recording all the parameters in the register. (05 Months)
Sigma Fire Protection
Max Fire Protection