| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.9 LAccepted-AOC AWANTA BHAWAN SOURA SRINAGAR 190011 J K | SRINAGAR | JAMMU AND KASHMIR | 190011 | L1 | Accepted-AOC Firm being L1 | |
| 2 | L2₹29.0 L+₹1.1 L (3.79%)Rejected-Finance | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹30.1 L+₹2.2 L (7.76%)Rejected-Finance 361 BEHIND DAV SCHOOL JAWAHAR NAGAR SRINAGAR 190008 | SRINAGAR | JAMMU AND KASHMIR | 190008 | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹31.2 L+₹3.2 L (11.5%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹31.9 L+₹4.0 L (14.3%)Rejected-Finance | L5 | Rejected-Finance Not Lowest |
Tender Value
Refer Docs
EMD Value
₹57,380
Closing Date
6 Apr 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE
GE 860 EWS
PROVN OF GARBAGE PITS NEAR 04 COOK HOUSES, HARD STANDING NEAR MT AND 02 SENTRY POST NEAR OFFICE COMPLEX AND OFFR LIVING AREA IN CERTAIN UNIT AT DURBUK AND OTHER SANCTIONED WORKS AT TANGTSE UNDER GE 860 EWS
2021_MES_423372_2
8165/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Tangtse
Class D
category b i
9 documents required · 9 mandatory
₹500
Yes
₹57,380
Yes
27 May 2021
16 Mar 2021
8 Apr 2021
16 Mar 2021
6 Apr 2021
30 Mar 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m depth for laying of cable/ stay assy/LT poles and foundation etc and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches exceeding 1.5 m wide and exc 1.5 m depth but not exceeding 3.0 m for foundation of poles and getting out in hard/dense soil complete all as specified and directed by Engr-in-Charge.
Returning filling incl spreading watering and well ramming in layers not exceeding 25cm in hard and dense soil complete all as specified and directed.
Removing excavated material not exceeding 50 mtrs and depositing where directed at a level n. exc 1.5mtr above the starting point complete all as specified and directed.
Sand cushioning to underground cable complete all as specified in clause 19.75 of SSR Part - I.
Laying only un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick retrived from item ser No 9 complete all as specified.
Material and labour for un-reinforced pre-cast concrete cable covers, class LV type-1, flat size 250mm x 150mm x 40mm thick complete all as specified.
Material and labour for Plain cement concrete 1:4:8 type D-2 (using 40 mm graded crushed stone aggregate) as in foundation of poles/stay assy including use of necessary form works for rough finished surface complete all as spd.
Material and labour for PCC 1:3:6 type C–1 (using 20 mm crushed graded stone aggregate/as in coping for poles and necessary form work for rough finished surface complete all as specified and as directed.
Supply and fixing in replacement tube medium grade galvanized with all fitting and fixed complete to walls/ poles/ ceiling or laid in floor of size 40 mm bore for the protection of UG cables including dismantling/ taking out old, unserviceable one complete all as specified and as directed.
Taking Down UNSV Cable and Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 10Sqmm 4core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
Taking out old unsv changeover and S&F off load change over switch side handle operated 415 volts 50 Hz 4 pole of rating 200 Amps mounted on angle iron frame incl PCC works completed all as specified & directed by Engr-in-Charge.
M & L Steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-22 (8.5 metres long) all as specified duly factory painted with two coats of black bituminous paint internally through out and externaly for embeded portion and painting with one coat of red oxide primer, applying two coats of synthetic enamel aluminium paint on remaining exposed surfaces after errection complete, painting with synthetic enamel paint of colours black and yellow alternate strips of 30cm width upto 1.5 mtr from the top of coping complete including making suitable holes where required all as specified and directed.
Dismantling and taking down Street light bracket, flat iron clamp, nuts bolts etc and supply and fix GI Street light bracket of size 32mm light grade, 1.5 metre long pipe in new or old location alingwith two numbers of clamp, nut bolt and washers of suitable size for fixing bracket all as directed at site.
Dismantling and taking down unserviceable street light fitting of any watt from LT poles and Supply and fix new generation energy saving and environmental friendly long life led street light of 70 watt made up of pressure die cast aluminium housing with high efficient led as lighting source with toughened glass having IP66 protection and impact resistance of IK07 complete all as specified.
M&L, in replacement, junction box outdoor type of size 17cmX22cm made out of MS sheet of thickness not less than 1.6 mm having hinged front opening door with two nos aluminium strip bus bar fitted on resin based insulator and flat iron fixing clamp of size 25mmX3mm and complete painted with two coat of synthetic enamel aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply, installation, testing and commissioning of feeder pillar box in repair for distribution on control panel, cubical type, factory made, outdoor type, dust and vermin proof, fabricated out of mild steel sheet of thikness 3.15 mm and mild steel angle iron 50x50x6mm thick (frame) complete with openable shutters in front and rear having proper locking arrangement including 04 Nos legs made out of angle iron 75mm x 75mm x 6mm thick, height of each leg shall be 75 cm duly grouted in PCC. Panel shall be spray painted internally and externally with two coats of synthetic enamel paint over a priming coat of red oxide primer and pre wired with suitable size of PVC insulated sheathed copper conductor cable complete in all respects and comprising of following accessories/fittings :- (a) MCCB 4 pole, 200 Amps, 415 Volt, AC with rupturing capacity not less than 25 KA = 01 Nos (i/c) (b) MCCB 4 pole, 100 Amps, 415 Volt, AC with rupturing capacity not less than 25 KA = 02 Nos (o/g) (c) MCB DP, 63 Amps, 240 Volts, 10 kA-03 Nos (o/g) (d) MCB DP 20 Amps, 240 volts 10 ka- 02 Nos (o/g)
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 metres below normal ground level, connecting to the Galvanized iron earth wire 4.0 mm dia by means of bolts, nuts , check nuts and washers of galvanized iron and steel earth wire protected by provision of GI light grade pipe 15 mm bore including provision of concrete pit made from PCC ( 1:2:4) type B-1 (using 20 mm graded stone aggregate) with 40mm thick cover of RCC 1:2:4 reinforced with XPM (Weight not less than 4 Kg/Sqm) and frame of angle iron 40 x 40 x 6 mm and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 1.50 metre long placed on top edge of earth plate, common salt & charcoal filling, with fixing arrangement , funnel, wire mesh and earth work in hard/dense soil , returning filling in and removal of surplus soil to a distance not exceeding 50 metres, all as per electrical plate No 5 of SSR 1991 Part-I and connecting to CBDB’s as specified or indicated including testing on completion .
Taking Down UNSV Cable and Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 120 Sqmm 3.5 core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
Taking Down UNSV Cable and Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 95 Sqmm 3.5 core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
Taking Down UNSV Cable and Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 50 Sqmm 3.5 core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
Taking Down UNSV Cable and Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor (Stranded) 1100V grade cross-sectional area 25Sqmm 3.5 core laid in trenches or passing through pipe or fixed on pole etc complete all as specified and directed by Engr-in-Charge.
M & L Precast cement concrete block masonry type C1 1:3:6 (20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all as Specified.
M & L Precast cement concrete block masonry type B1 1:2:4 (20mm graded crushed stone aggregate) with solid blocks, exc. 10cm in width and, setting in cement mortar 1:6 complete all as Specified.
Material and labour for Second class hard wood plain solid straight chowkats and frames wrought, framed, rebated on the solid rounded or chamfered put together with glue pinned at joints complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 150mm size aluminium,anodized barrel tower bolts of extruted section and fixed complete all as specified.
Supply and fix 150mm size extruded aluminium door handles fabricated type complete all as specified.
S&F of 200 mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy complete all as specified and directed by Engr-in-Charge.
M&L for Preparing new wood and wood based surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
M & L for surface dressing n.exc 15 cm deep in soft /loose soil complete all as specified and directed by Engr-in-charge.
M & L for PCC 1:4:8 type D -2 ( Nominalmix) using 40 mm graded crushed stone aggregate as in foundation filling and similar work complete.
M&L for Hardcore gauge n exc 63mm deposited spread and levelled in layers n exc 15 cm thick waterd and rammed to a true surface complete as specified and directed by Engr-incharge
M&L for 100mmm thick cement concrete type D-2, 1:4:8 (using 40mm graded crushed stone aggregate( in sub base concrete complete all as specified and directed by Engr-incharge
M& L for cement concrete 40mm thick type B - 1 , 1:2:4 using 20mm graded crushed stone aggregate over sub base and finishing the surface even and fair without using extra cement complete all as specified.
M& L for cement concrete 75mm thick type C - 2,1:3:6 using 40mm graded crushed stone aggregate in plinth protection complete all as specified.
M&L for preparation of new plastered surface of wall and applying three coats of white washing on plastered surface complete all as specified and directed.
M&L for RCC in foundations, Type B1 1:2:4 (20mm graded crushed stone aggregate) including rafts, footings, foundation beams, plinth beams, bases for columns, etc. basement slabs, under reamed piles and mass concrete including necessary form work all as spd & directed.
M&L for RCC in beams, cantilevers, bressummers, lintels over 1.5m span Type B1 1:2:4 (20mm graded crushed stone aggregate) complete including necessary form work all as directed and specified.
M &L mild steel TMT bars 10mm dia and over cut to length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M &L mild steel TMT bars but 5mm dia and over up to and including 10mm dia in strippus, spacers and binders, length, bent to shape required, including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire(annealed ) not less than 0.9mm dia or securing with clip complete all as specified and as directed.
M&L for 15mm thick cement plaster on fair faces of concrete surfaces in cement morter 1:6 finished even and smooth without using extra cement complete all as specified
M&L for 10mm thick cement plaster on fair faces of concrete surfaces in cement morter 1:6 finished even and smooth without using extra cement complete all as specified
M & L for preparing of new surfaces of any description and applying two coats of cement base paint on wall complete all as specified
Supply and fix factory made 30 mm thick second class hard wood plain framed paneled shutters (two panels) with lock rail and panels of 9 mm BWP commercial ply or 12 mm veneered particle board for others with commericial veneering on both faces and size of members of door shutters as per IS :1003(part I ) as specified in SSR part I section 3 clause 8.20 (a) fitted to chowkats, kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge
S&F 4mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc 0.5 sqm in each pan complete all as specified
S&F 125mm long butt hinges medium weight, cold rolled mild steel and fixed as spd and directed.
S&F Steel work 40mm in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to ISI 1161-1998 grade St-240 complete all as specified
S&F Galvanised Corrugated mild steel sheeting 0.63mm thick with two corrugations side lap, as in wall cladding and roof of hangers and blast pens fixed with J or L hooks or cranked bolts and washers, wirh grade of zinc coatings 275 gm per sqm complete and all as Specified.
M&L for preparation of new or previously untreated steel and iron surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide complete all as spfd.
Surface excavation not exceeding 30cm deep and averaging 15cm deep and getting out in any type of soil complete all as specified and directed.
M & L for PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base 75mm thick complete all as specified and as directed.
S&F Machine pressed precast concrete interlocking glazed paver block with grey cement and no pigment of any shape and size conforming to IS 15658 - 2006 of 80 mm thickness M - 40 grade including 50 mm sand cushion including packing joints etc complete all as specified and directed.
M&L PCC 1:2:4 Type B-I using 20 mm graded crushed stone aggregate as coping or packing of sides, edges etc including necessary form work complete all as specified.
M&L for rendering 15mm thick, in cement mortar 1:4 on PCC block walling or concrete surfaces and finished the surfaces even and fair without using extra cement complete all as specified.
TARIQ AMIN LONE
M/S TRADE LINK
M/S LIBE & CO
M/S GEE AAR and SONS ENTERPRISES
osho traders
H R CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .