Loading…
Loading…
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
10 Feb 2026, 11:00 amClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
90 days
Expenditure
Capital (Works)
Above/Below/Par
TECHNICAL
15 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of [V/N or 'V' whichever is less; where V = Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must submit a valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by the Government Electrical License Board on or before the closing date of the tender. A copy of the electrical contractor license should be submitted along with the tender offer, otherwise, the tender will be summarily rejected.
The Similar nature of works for this instant tender shall be "Supply, installation, testing and commissioning of any LT/HT electrical work." The tenderer should have executed the similar nature of works in the Central/State Government department or PSUs of the Central/State Government."
55 conditions · 4 needing a document upload
Whether the cost of earnest money deposited
WHETHER VALID ELECTRICAL CONTRACTOR LICENSE WAS SUBMITTED
Migration to GST regime - Special Tender Conditions: The rates should clearly indicate the rate of applicable duties and taxes included in the prices quoted by them. Any variation in tax structure/ rate due to introduction of GST, shall be dealt with under Statutory Variation Clause. It should be ensure that bidders/tenderers are GST compliant and quoted tax structure/rates are as per GST Law.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Contractor should submit the GSTIN number and same should be mentioned in the bills along with a copy of GSTIN registration certificate while submitting the bills to accounts for audit and payment, As GST is scheduled to implemented wef 01.07.2017. Without GSTN, no bill will be accepted w.e.f. 01.07.2017
From 01.07.2017 GST has been implemented but the detail guideline is still not clear. Hence, new tax structure on materials and labour will be applicable to both Railway & contractor after getting proper notification
Payment of Earnest Money deposit (EMD) , in respect of e- tendering,should be accepted through net banking or online payment gateway only
Construction & Electrification of Railway quarters at NHGJ, SCL, KXJ, JID, NGAN, BRLF, HBN (Electrical Portion).
EL-LM-25-26-36~NFR
EL-LM-25-26-36
Open
Works - General
160 Days
Hojai, Assam
₹0
₹2.1 L
10 Feb 2026
19 Jan 2026
27 Jan 2026
620 items across 8 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 7,97,539.6 | ||
| — | 96.00 | — | — | ||
| Supply of materials and wiring of light point through concealed wiring by 1.5 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch(with indicator type) to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. Make - Cable- Finolex, Havells, KEI, Polycab Casing & Capping/Conduit - Diamond, Presto Plast, Richa C/Rose & Switch - Crabtree, Anchor, Legrand. | — | — | — | 45,294.72 | |
| — | 36.00 | — | — | ||
| Supply of materials and wiring of fan point through concealed wiring by 1.5 sq mm single-core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single-core PVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch (with fan marking) and module type step fan regulator of 100 W to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes. (i.e., the thickness of mounting boxes of 3 mm and the inside width of the box should be 50 mm). All other necessary accessories, i.e., PVC tees, bends, etc., will be supplied by the contractor. After being concealed, if needed, then the concealed portion will be painted by the contractor as per the site color of the surface. | — | — | — | 18,064.08 | |
| — | 36.00 | — | — | ||
| Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required | — | — | — | 98,280 | |
| — | 24.00 | — | — | ||
| Supply; Wiring of concealed exhaust fan point by PVC insulated unsheathed and multi stranded FRLS Copper Cable 1.5sq.mm S/C confirming to IS - 694/1990 through suitable size (19 mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm including ceiling rose and 10 AX one way modular switch in 1/2 M concealed unbreakable GI modular box, 2 M cover plate etc. with 1sq. mm unsheathed copper cable as earth continuity wire. | — | — | — | 7,509.6 | |
| — | 24.00 | — | — | ||
| Supply, fitting, fixing, connection & commissioning of 300 mm sweep heavy-duty exhaust fan. All consumables regarding fixing arrangements will be supplied by the contractor as per the direction of the engineer in charge at site. | — | — | — | 31,371.6 | |
| — | 120.00 | — | — | ||
| Excavation of cable trench 1.0 m x 0.5 m below the GL with laying of armored cableand refilling the same by supply of Brick, Sand and Soil after digging the earth asper direction of Engineer at site & connection of armored Cable by supply and fixingof crimping lugs etc. | — | — | — | 14,614.8 | |
| — | 300.00 | — | — | ||
| Excavation of cable trench 1.0 m x 0.5 m below the GL with laying of armored cable and refilling the same by supply of Brick, Sand and Soil after digging the earth as per direction of the engineer at site & connection of armored Cable by supply and fixing of crimping lugs etc. | — | — | — | 72,447 | |
| — | 720.00 | — | — | ||
| Supply and wiring of sub-main line (concealed type) by 1.1 KVgrade HRFRPVC insulated single core 4 sqmm multistrand flexible copper cable conforming to IS:694/1990 through 25mm dia. PVC conduit pipe including earth continuity by HRFRPVC insulated singe core 4 mm2 multi flexible stranded copper wire (One RM consists of 2 wires) as per direction of Engineer Incharge at site. | — | — | — | 83,152.8 | |
| — | 36.00 | — | — | ||
| "Supply of materials and wiring of 16 amps plug point through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire and modular type 16 amps controlling switch(with indicator type) and 3 modular 16 Amps 6 Pin universal socket to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes. (i.e thickness of mounting boxes of 3 mm and inside width of box should be 50 mm). All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. surface." | — | — | — | 14,975.64 | |
| — | 48.00 | — | — | ||
| Supply of materials and wiring of 6 amps plug point through concealed wiring by 1.5 sqmm single core PVC insulated flexible industrial unsheathed FRLSH copper wirethrough PVC concealed rigid conduit pipewith earth continuity by 1 sq mm single corePVC insulated unsheathed flexible copper wire and modular type 6 amps controlling switch (with indicator type) and 2 modular 6Amps 5 Pin universal socket to be provided on good quality modular plate and frame of suitable sizes and mounting box of proper sizes.(i.e thickness of mounting boxes of 3mm and inside width of box should be 50mm). All other necessary accessories i.e PVCTee, Bend etc will be supplied by contractor.After concealed if needed than the concealed portion will be painted by contractor as persite colour of the surface. | — | — | — | 15,178.56 | |
| — | 12.00 | — | — | ||
| Supply and wiring of geyser point by good quality accessories with proper connection complete with 15 amps plug point and16 amps DP MCB overload protection, through concealed wiring by 4 sq mm single core PVC insulated flexible industrial unsheathed FRLSH copper wire through PVC concealed rigid conduit pipe with earth continuity by 1 sq mm single core PVC insulated unsheathed flexible copper wire: All other necessary accessories i.e PVC Tee, Bend etc will be supplied by contractor. After concealed if needed than the concealed portion will be painted by contractor as per site colour of the surface. | — | — | — | 5,627.16 | |
| — | 12.00 | — | — | ||
| Supply and erection of earthing, the earthing pipe should be made of B class GI pipe of 4000 mm length, 50 mm diameter & 3.6 mm thickness. The GI Strip should be welded with the earth pipe. The pipe is provided with a tapered casing at the lower end in order to facilitate the driving. A funnel with perforated plate to be provided at the top of the pipe for pouring clean water during dry season to have an effective earth value. The earth fill shall be of homogeneous layer of common earth soil. Where soil restivity is high, earth restivity enhancing material may be used, Bentonite or similar earth enhancing material may be used in rocky soil. Earth box to be precasted RCC, This will supersedes the earlier drawing no. PCEE/ELG/DRG/2024/1 dated 30.09.24. As Per Drg No: PCEE/ELG/DRG/2024/1/Rev-1 Dated 28.07.2025. | — | — | — | 16,245.72 | |
| — | 24.00 | — | — | ||
| Supply, fitting fixing of 20 watt Led indoor batten tube light. | — | — | — | 11,880 | |
| — | 24.00 | — | — | ||
| Supply and fitting of 9 watt, LED BULB | — | — | — | 3,600 | |
| — | 24.00 | — | — | ||
| Supply and fitting of 7 watt, LED BULB | — | — | — | 3,360 | |
| — | 24.00 | — | — | ||
| Supply and fitting of 0.5 watt, LED BULB | — | — | — | 1,080 | |
| — | 12.00 | — | — | ||
| Supply, wiring, testing & commissioning of concealed call bell point wiring by FR-LSH PVC insulated and unsheathed 1.5 sq mm, single core flexible copper wire concealed on the wall through PVC rigid conduit pipe/Polyethylene pipe of dia not less than 20 mm dia with all types of joints and bends as required complete with 6 amps bell push controlling switch fitted on half flush MS board with hylem sheet topand earth continuity wire by PVC insulated and unsheathed 1 sq mm ,single core multi strand copper wire complete to be concealed in wall including supply, fixing, testing & commissioning of call bell "Ding Dong/Multitone door bell". Wiring through Double lock PVC casing capping of not less than 19 mm width & minimum thickness of 0.85 mm may be provided, if required as per instruction of the engineer-in-charge at site. | — | — | — | 4,902.24 | |
| — | 12.00 | — | — | ||
| "Supply, installation, testing and commissioning of Single phase, 2 wire prepaid meter (in replacement of existing 01 phase, 02 wire meter). Single source direct connected pre-paid keypad based BIS marked IS-15884 Digital Energy meter, 10-60 Amps, 240 Volts, accuracy class1.0 along with parallel Consumer interface unit and soft token transfer device at House, with facility of meter to generate ABC code (Authenticated Billing Code) for Monthly Energy usage bill generation , having LCD type display, calibration LED, numeric key pad for token entry with RS 232 communication port, LED for credit status indication, push button for scroll and having features for load disconnection in case the credit limit become zero or increase of load than the permissible limit, reconnection and disconnection of load, buzzer at Consumer interface unit to give alarm in case of low credit and o verloading and data download port for last 25 tamper vent and load survey for last 30 days with all standard antitamper features including sealing facility complete all as directed. Make: HPL /Havells/ Schneider/L&T/Secure" | — | — | — | 91,150.8 | |
| — | 12.00 | — | — | ||
| Provision of 8-way SPN DB single door with I) 1 no. 32 amps DP MCB ii) 10 amps SP MCB - 4 nos iii) 40 A RCCB, 30 mA - 1 no----Complete 1 set | — | — | — | 89,460 | |
| — | 12.00 | — | — | ||
| Supply,installation,testing and commissioning of 16 amps 240 volts DP main switch with side handle with porcelain type rewirable Switch fuse unit | — | — | — | 6,694.92 | |
| — | 4.00 | — | — | ||
| Supply, installation, testing & commissioning of SMC outdoor water proof junction box TPN for 100 A busbar with suitable angle/channel and foundation work. | — | — | — | 64,320 | |
| — | 8.00 | — | — | ||
| "Supply, installation, testing & commissioning of 45 wattoutdoor LED street light luminaire with heat resistantglass with connecting lead (IP protection- IP 66 class-I,System efficacy>=105 lm/w, Housing- Pressure die castaluminium powder coated, THD<10%, p.f.>0.95, Surgeprotection- 5 kV) as per instruction of Engineer inchargeat site. (Embarcking maximum light to ensure visibilityat night to persons with low visibility) | — | — | — | 30,686.64 | |
| — | 500.00 | — | — | ||
| Laying, commissioning of LT/HT cable XLPEinsulated power cables with armoured aluminum conductors of different sizes (4core 95 sqmm) partly along the pole andpartly through ground in cable trench.Loading, unloading & carrying of cable toactual work site by contractor own arrangement as per instruction of Engineer incharge at site. (Cable will be supplied by Railway.) | — | — | — | 20,465 | |
| — | 500.00 | — | — | ||
| Supply, fitting and laying of Single core 2.5 sqmm Flame Retardant PVC insulated industrial grade multistrand copper conductor(unsheathed) flexible cable voltage grade upto1100 Volt.(Conforming to IS 694:2010) | — | — | — | 17,735 | |
| — | 169.00 | — | — | ||
| — | 24.00 | — | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .