Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.7 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹21.0 L+₹99,574.91 (4.98%)Rejected-Finance JAISALMER | BARMER | RAJASTHAN | 344001 | L2 | Rejected-Finance NOT BEING L1 BIDDER | |
| 3 | L3₹21.6 L+₹1.6 L (8.23%)Rejected-Finance 521 DR K L ACHAL VANSHI COLONY JAISALMER 345001 RAJ | JAISALMER | RAJASTHAN | 345001 | L3 | Rejected-Finance NOT BEING L1 BIDDER | |
| 4 | L4₹22.7 L+₹2.7 L (13.4%)Rejected-Finance VILLAGE SATOJ TEHSIL SUNAM DISTT SANGRUR | SANGRUR | PUNJAB | 148001 | L4 | Rejected-Finance NOT BEING L1 BIDDER | |
| 5 | L5₹23.5 L+₹3.5 L (17.6%)Rejected-Finance GANDHI CHOWK MANIPURA JAISALMER RAJ 345001 | JAISALMER | JAISALMER | RAJASTHAN | 345001 | L5 | Rejected-Finance NOT BEING L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹44,000
Closing Date
20 May 2021, 6:00 pmClosed
GE Army Jaisalmer
GE Army Jaisalmer 345001
SPL REPAIR TO BLDG No. P-757 AT KHAMBATTA AND PROVN OF COMPOUND WALL/CATTLE FENCE AROUND THE BLDG No. P-757 AT MIL STN JAISALMER
2021_MES_433349_2
8981/21-22/E8
Open Tender
Civil Works
Item Rate
180 days
Jaisalmer
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Jaisalmer
₹44,000
Yes
30 Jul 2021
30 Apr 2021
22 May 2021
30 Apr 2021
20 May 2021
7 May 2021
Amount
Demolition Brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all as specified and directed.
M &L Squared rubble walling Jodhpur type, brought upto courses, well bonded, bedded and solidly hearted, built in CM 1:6, complete all as specified and directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc.complete all as specified and directed.
M&L for post construction treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M&L for post construction treatment along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. in apron, complete all as specified and directed.
M&L for precast cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in solid block masonry exceeding 10cm width and setting in cement mortar 1:6 complete all as specified and directed.
M&L for rendering 15 mm thick on stone masonry wall surfaces or surfaces other than fair faces of brick work or one side of lathing in cement mortar (1:6) and finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 5mm thick on ceiling surfaces in cement mortor 1:3 ,finished even and smooth without using extra cement complete all as specified and directed.
M & L for preparation of old plastered surfaces with complete removal of existing treatment and applying two coats of cement base paint with Priming plastered and other surfaces with alkali resistant priming paint on walls complete all as specified and directed.
M&L for preparation of old plastered surfaces of wall with complete removal of existing treatment and applying two coats of destemper oil emulsion over 3mm thick wall care putty complete all as specified and directed.
M&L for preparing old surface of ceiling and applying one coat of white wash complete all as specified and directed.
M&L preparation of old painted steel surfaces of any description over 10cm width or girth, not other wise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparing new surface of wall and applying two coat of oil bound distemper over one coat of 3mm putty including one coat of primer on newly plastered surface complete all as specified and directed.
M & L preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L for granite (of any type) tile 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing laid on complete all as specified and directed.
M&L for vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed in CM 1:6 (size 600mm x 600mm) complete all as specified and directed.
M&L for vitrified ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in dado/skirting etc. set and jointed in neat cement slurry and pointed in coloured cement over 10mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for glazed ceramic coloured tiles (Joint free0 of size 350 x 250mm x 7mm /450mmx350mmx7mm thick on vertical surface such as skirting, dados, risers to steps etc set & jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over and including 15mm thick backing coat in CM (1:4) all as specified and directed by Engineer-in-charge.
M&L for non - skid ceramic coloured tiles (Joint free) 7 to 8 mm thick area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer 15mm thick in CM 1:6 complete all as specified and directed.
Taking down chowkats or frames exc 1.5 sqm but not exceeding 4 sqm each without taking off shutters from the frames including iron mongry complete all as specified and directed.
Taking down chowkats or frames n.exc 1.5 sqm each, without taking off shutters from the frames including iron mongry complete all as specified and directed.
S&F anodised aluminium alloy handles cast type, 150mm long complete all as specified and directed.
M&L for anodised aluminium frame for doors, windows ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and directed.
S & F anodised aluminium door shutters of any colour including powder coating (Thickness of powder coating not less than 50 micron), aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc complete all as specified and directed.
S & F anodised aluminium window and ventilator shutters of any colour including powder coating (Thickness of powder coating not less than 50 micron), fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and directed.
S&F 5.5 mm thick sheet glass ordinary quality and glazing with oil putty in squares exceeding 0.50 Sqm in each pane, complete all as specified and directed.
S&F in repair aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples, complete all as specified and directed.
S&F in repair, aluminium (Die cast) door closer hydraulically regulated designation No. 3, universal type, suitable for door shutter of 851 mm to 1000mm in width and of weight between 61 to 80 Kg complete all as specified & directed.
S&F aluminium 4 levers rebated mortice lock, vertical type, size 75 mm complete all as specified and directed.
S&F in repair, 20mm dia curtain rods, mild steel chromium plated with fixing brackets, stops, rollers complete all as specified and directed.
S&F PVC solid doors frame of size 50mm x 47mm made out of 5mm plane colour PVC sheet reinforced with MS tubes complete all as specified and directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame out of MS tubes for top and bottom rails MS frame shall be covered with sheet moulded plain coloured PVC 'C' channel having a PVC sheets of 20mm width stuck inside with solvent cement for site and frame coloured PVC sheets for top rails as gap insert for top rails on either side and as gap insert for top rails and bottom rails pannelling of plain coloured PVC sheets to be fitted in the MS frame welded sealed to the site and rails with suitable PVC sheets beading and joints together with solvent cement in the frame at site as per specification and drawing complete all as specified and directed.
Dismantling (AC corrugated, semi corrugated etc ) AC sheets in roof coverings, complete all as specified and directed.
S&F pre painted galvalume aluminium zinc coating GI based corrugated steel sheet/ semi corrugated 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not othervise provided for that purpose complete all as specified and directed.
S & F rolled mild steel in joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated) type of Fe 410-W (Gde E- 250) quality 'A', complete all as specified & directed by Engineer in charge.
M&L for preparation of new or previously untreated steel surface of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint (ordinary tint) over a coat of red- oxide, zinc chrome primer complete all as specified & directed.
Demolition of cement concrete (un reinforced) in ground floors and pavings n.exc 15 cm thick (below or above ground level) & removing rubbish out side MD land complete all as specified and directed.
M&L for 75mm thk cement concrete 1:4:8 type D2 using 40mm graded stone aggregate as in subbase of flooring/hard standing complete all as specified and directed.
M & L for 50mm sand cushion, filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 25mm thick PCC 1:2:4 type B0 using 12.5mm graded stone aggregate as in floors & finishing the surface even & smooth without using extra cement complete all as specified and directed.
M&L for Endura ceramic tiles exterior grade of size 300 x 300 x 10mm thick including 15 mm thick screed bed in CM 1:6, set and jointed in neat cement slurry and pointed in coloured cement to match all as specified and roughening of exc concrete surfaces complete all as specified and directed.
M& L for rubber moulded machine pressed precast concrete interlocking paver block with grey cement and pigments any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade, all as specified and directed by Engr-in- charge
S&F 150 mm size aluminium anodised barrel tower bolts of extruded section all as specified & directed by Engineer-in-charge.
S&F 100mm size Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type C-21 complete all as specified & directed by Engineer-in-charge.
S & F aluminium handle of 125 mm size cast type anodized complete all as specified and directed.
S&F in repair stop valve 15 mm bore cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both ends for iron pipe or for union complete all as specified and directed.
Supply only Integral waterproofing compound complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm but not exc 2 Sqm each complete all as specified and as directed
S & F factory made second class hard wood plain framed panelled shutters 35mm thick with panels of timber flat on both sides (feather edged) or of veneered particle board medium density wood particle tone veneers, fixed to chowkat, complete all as specified and directed.
M&L for preparing new or previously untreated wood and wood based surfaces of any description otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (Ordinary tint) over a coat of pink primer complete all as specified & directed.
S & F in repairs, galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples, complete all as specified and directed.
M & L in repair, sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long complete all as specified and directed.
S&F in repair PVC connection pipe for WHB, cistern, gysers etc of size 15 mm dia and 450 mm long complete all as specified and directed.
Cutting chases in stone concrete block or slab, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, in CM cutting exc 10 cm but not exc 20 cm girth in stone, concrete block or slab walls complete all as specified and directed.
S&F in repair chromium plated shower rose 15 mm bore with swivel joints any size incl fixing to steel pipe complete all as specified and directed.
S & F in repair bib tap cast copper alloy fancy type chromium plated screwed down, screwed for iron pipe or for brass ferrule and fixed 15mm dia
S & F in repair CP brass Towel rail 20mm dia, D type, 60 cm long complete fixed in wall with screws complete all as specified and directed.
S&F in repair brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed for 15mm dia bore complete all as specified and directed.
Taking up or down steel tubing and connections of following size all as directed by Engineer-in- charge :-
(a) 15 mm bore
(b) 20 mm bore
S&F GI tubing (ISI) marked) medium grade with all fitting and fixed complete to wall ceiling or laid in floors of following size :-
(a) 15 mm bore
(b) 20 mm bore
S&F aluminium anodised sliding door bolt 250mm long, with hasp staple, (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
Dismantling boarding, any description, fixed in any position with nails complete all as specified and directed.
S&F in repair 12 mm prelaminated particle board, exterior grade, prelaminated both side with decorative choice laminations fixed with screws to timber frame work and alumunium frame complete all as specified and directed.
S & F Continuous (piano) hinges, mild steel, bright finish or electrogalvanised 40mm thick complete all as specified and directed.
S & F 100 mm thick Brass handles, cast type, polished bright complete all as specified and directed.
S& F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting complete all as specified and directed.
S&F in repair vitreous china wash basin white, oval type including waste fittings, brass, chromium plated, coupling, waste pipe, brackets including cutting for and pinning in ends of brackets errect stand, fixing waste pipe, complete all as specified & directed by Engineer-in-charge. (Make :- Cera -S2030103, Hindware -10017, Jaquar Cat Part No. CNS-WHT-705).
S & F in repair pressure jet for western type water closet with PVC connection 600 to 900 mm long including brass head screw and suitable washer complete all as specified and directed.
S&F in repair standard size chromium plated toilet paper holder of brass fixed to walls with chromium plated (CP) brass screws complete all as specified and directed.
S&F in repair standard size stainless steel wall mounted square soap dish with SS holder complete all as specified and directed.
S&F in repair 1mm thick stainless steel double bowl Sinks of grade SS304, kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe with mirror finished rectangular in shape , overall size 1040mmx 510mm, bowl size 405mm x 355mm, complete all as specified and directed.
S&F in repair one piece EWCs with duroplast soft close seat cover and twin flush fittings snow white( crusiser 710 x390 x 790 mm cera cat no SLS-WHT-6855S or eqivilant including connection to drain (or outgoing pipe) complete all as specified and directed.
M&L for screed bed 15mm thick in plaster in cement mortar 1:4 on concrete surfaces duly mixed with water proofing compound and finished even and smooth by using steel trovel (WPC will be measured saprately) complete all as specified and directed.
M&L for APP based polymeric membrane minimum weighing 3.5 Kg/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (wt not less than 160 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 Ltrs/Sqm by torched application including taking down of exisiting roof treatment completely in all respects, complete all as specified and directed. Roof treatment consist of as under:- (1) Applying 1 coat or bituminous primer conforming to IS-3384 @ 0.3 ltrs/Sqm (ii) laying of APP based membrane as specified thickness and weight. (iii) Applying 2 coat of Al paint @ 100 ml/sqm complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and and getting out in hard/dense soil complete all as specified & directed.
M&L for plain cement concrete 1:4:8 type D2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified & directed.
M&L for plain cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate cast in situ in lintels up to 1.5 m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings up to 60 cm in height, copings, kneelers, apex stones, bed plates, water through and the like including weathering, slightly rounded or chamfered angles and throating including use of form work (straight or curved) complete all as specified & directed.
Returning, filling in, including, spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soil all as specified & directed.
Removing excavated soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified & directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete all as specified & directed.
M&L for 35mm thick precast cement concrete (1:3:6) type C-0 using 12.5mm graded stone aggregate as in louvers or jallies (measured solid), including all mouldings but excluding frame, set in cement mortar (1:6) complete all as specified & directed.
M&L for pre-painted galvalume aluminium zinc coating GI based plain steel sheeting 0.50 mm thick any colour having tensile strength 550 Mpa as in roof coverings/cladding to wall, fixed with self tapping screws etc complete all as specified & directed.
M&L for mild steel TMT bars 10mm dia & over cut to length, bend to shape required, including cranking, bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified & directed.
S&F mild steel framed work such as grills, gratings, etc with ends of bars shouldered and / or riverted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, raillings, frame work of water tanks and similar work confirming to Fe-290 grade E-165 for portions framed and hung as gates, including pintle hinges, stops, hand-made sliding bolts, etc complete all as specified & directed.
Taking down existing unserviceable point wiring of any description/type/ size of light/fan/tube/power/two way/bell etc GD power/ aluminium wire on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site and making good the disturbed surfaces of wall/ceiling so as to match with the existing finishes all as specified.
Taking down the existing unserviceable main switch / cut out / DBs of any type / capacity / description as existing at site including MCBs any type and capacity making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down the existing unservicable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes all as specified.
Taking down of old unserviceable garden light/ gate light of any description complete all as specified
M & L for Point wiring using colour coding as per IS with 1.5 Sq mm multistranded copper conductor single core FRLS PVC insulated unsheathed 1100 Volts, ISI-694 marked drawn through PVC concealed conduit of suitable size, with GI Modular sunken boxes of 1.2 mm thick, 60 mm depth of suitable size/Module as per site requirement including fixing/ grouting sunken and making good to match with existing finishes including provision of cover with white colour Modular frame plate of suitable size for fixing modular switches/ Socketd and Modular fan regulators including running up of 1.5 Sq mm copper conductor FRLS, PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly complete all as specified & directed for the following :
(a) One light point controlled by one, one way switch
(b) One ceiling fan/ exhaust fan point controlled by one, one way switch and regulator.
(c) One three pin 5 Amps socket outlet point controlled by one No one way switch on same board
(d) One three pin 5 Amps socket outlet point controlled by one No one way switch on independant board
(e) One bell point controlled by one switch
All as per Item No. 92.00 above but with stranded copper conductor 4.0 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded FRLS copper conductor 4.0 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
M & L for Point wiring using colour coding as per IS with 1.5 Sq mm multistranded copper conductor single core FRLS PVC insulated unsheathed 1100 Volts, ISI-694 marked drawn through medium grade PVC casing caping of suitable size, with GI Modular sunken boxes of 1.2 mm thick, 60 mm depth of suitable size/Module as per site requirement including fixing/ grouting sunken and making good to match with existing finishes including provision of cover with white colour Modular frame plate of suitable size for fixing modular switches/ Socketd and Modular fan regulators including running up of 1.5 Sq mm copper conductor FRLS, PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly all as specified for the following :
(a) One light point controlled by one, one way switch
(b) One three pin 5 Amps socket outlet point controlled by one No one way switch on same board
(c) One three pin 5 Amps socket outlet point controlled by one No one way switch on icdependant board
(d) One bell point controlled by one switch
All as per Item No. 94.00 above but with stranded copper conductor 4.0 Sq. mm (nominal area), single core, PVC insulated and unsheathed multistranded FRLS cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated multistranded FRLS copper conductor 4.0 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
S & F for Modular Switch piano flush type, single pole, Noise less in operation one way, and 5/6 Amp single module complete all as specified & directed. (Make : Havellscrabtree, honeybell, Schneider)
S&F for Modular Socket outlet multipurpose having provision for 2 in 1, 3 pin 5 amp flush type , two Module complete all as specified & directed. (Make : Havellscrabtree, honeybell, Schneider).
S & F for Modular Switch piano flush type single pole Noise less in operation one way, and 15 amp,one Module complete ISI marked complete all as specified & directed. (Make : Havellscrabtree, honeybell, Schneider).
S&F for Modular socket outlet 2 in 1, 2/3 pin 5 Amps and 15 Amps flush type two Module complete all as specified & directed. (Make : Havellscrabtree, honeybell, Schneider).
S & F for celling rose 2/3 terminals, PVC/ polycarbonate, isolated body ISI marked complete all as specified & directed.
S & F for Modular stepped type fan regulator, Socket type, operating on 230 Volt 50 Hz complete all as specified & directed. (Make : Havellscrabtree, honeybell, Schneider)
S & F for Bell, Ding Dong AC, 230 Volts, single pole complete all as specified & directed.
S & F for Modular Bell push 6 Amp, 1 Module,Noise less in operation complete all as specified & directed. (Make : Havellscrabtree, honeybell, Schneider).
S & F for MCCB DB VTPN 4 way with provision for FP MCB/Isolator/RCCB etc as incommer and SP/TP MCBs as out going double door IP 43 complete prewired including Bus Bar etc suitable for operation on 415 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed . Make - Schindier/Legrand/L&T/ ABB or WIPRO etc
S & F MCCB 415 Volts, 4 Pole , 63 Amps, with breaking capacity 16 KA complete all as specified & directed.
S & F for MCB DB SPN 8 way double door IP 43 complete prewired including Bus Bar etc suitable for operation on 240 volt 50 Hz AC supply including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed .
S & F for MCB SPN double pole rated capacity 40 amps, 230 volts breaking capacity 10 KA with thimbles complete all as specified and as directed.
S & F for MCB Single pole rated capacity 32 to 63 Amps amps, 240 V breaking capacity 10 KA, with thimbles complete all as specified and as directed.
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 4.00 Sqmm (FRLS) in PVC Surface / concealed conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 4.00 Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge/ (Note :- Two runs of 4.00 Sqmm cable & one run of 4.00 Sqmm cable shall be paid as one unit length)
M & L for submain wiring with approved colour code/as per IS (Red,black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper conductor of nominal cross sectional area of 6.00Sqmm (FRLS) in PVC Surface / Conceiled conduit including one run of PVC insulated multistranded copper conductor nominal cross sectinal area of 6.00Sqmm (FRLS) of continous earth wire green in colour complete all as specified and directed by Engineer-in-charge. (Note :- Two runs of 6.00 Sqmm cable & one run of 6.00 Sqmm cable shall be paid as one unit length)
S & F for Decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and provosion of LED bulb 10 watts complete all as specified and as directed. (Make Havells cat part No. LHDL06160099 or equivalent make in , Philips, Bajaj).
S & F for LED tube light fitting 20 Watt 4 Feet or 1183 MM in lenth, IP 20 Protection, wall mounted type, Slim LED Batten with polycarbonate housing and diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver , IP 20 Protection, Opreating voltage 240 V , 50Hz AC Supply and Operating tempraeture 0 to 50 degree C , Power factor ≥ 0.9, Lumen output ≥ 2000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified and as directed. (Make Orient, Philips, Crompton, Havells)
S & F for LED tube light fitting 10 Watt, 2 Feet or 591 MM in length, IP 20 Protection, wall mounted type, Slim LED Batten with polycarbonate housing and diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having Integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V , 50Hz AC Supply and Operating tempraeture 0 to 50 degree C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white colour flexible pipe complete all as specified and as directed. (Make Orient, Philips, Crompton, Havells)
S & F in repairs Energy saving new generation 10 watts LED bulk head fitting IP 65 luminaire with opel diffuser pre wired and necessary mounting arrangements , provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including LED bulb complete all as specified and as directed.Make Orient, Philips, Crompton, Havells.
S&F in repair energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 30 watts with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting including bracket of GI pipe medium grade of 40 mm dia, 1.2 meter in Length clamps made of FI 40 mm x 6 mm Incl nuts,bolts & washers, painting complete all as specified and as directed. (Make Orient, Philips, Crompton, Havells).
Taking down ceiling fan / Exhaust fan of any sweep sealing cable end, dismanting blade and removing fan and blade to store complete all as specified and directed.
M & L for Painting of ceiling fan/ Exhaust fan complete in situ with synthetic enamel paint by spraying including filling cavity with filler one coat after cleaning all dust etc complete all as specified and as directed.
Taking down and refixing ceiling / exhaust fan after serviceing greasing change of bearing if reqd, including making serviceable and noise free in all respect and connecting up including provn of cable from ceiling rose or connector to fan complete all as specified and as directed.
Taking down storage geyser of any capacity after disconnecting electrical connection from existing socket, removing the bolts and nuts from wall and disconnected inlet and outlet water connection and handover to unit for keeping it in safe custody complete all as specified and as directed.
M & L for Painting of Old geyser of any capacity with white colour synthetic enamel paint by spraying and filling cavaties with pillar, one coat after cleaning all dust, with proper filling complete all as specified and as directed.
Refixing the geyser at it's original location after repair/ replacing the unserviceable items like Heating element, Thermostat, PVC Connection pipe of hot & Cold type, Changing of outer body with its inner tank if found unservicable, Making Geyser servicable in all respect complete all as specified and as directed. (Note: Rate Quoted by Contractor shall be inclusive for replacing all unserviceable item like Heating element, Thermostat, PVC Connection pipe of hot & Cold type, Changing of outer body with its inner tank etc.)
S & F sheet metal enclosure for Geyser / AC Box having 20 Amp MCB SP 1 No. as incomer complete all as specified and as directed.
S & F for LED post top lantern 40 watt light fitting made of cast aluminium spigot housing with decarative opal acrylic diffuser with IP 65 protection complete with all accessories fixed on GI pipe 50 mm dia complete all as specified and directed. (Make: Crompton Cat part No LPTO-40-CDL or equivalent Make i n PHILIPS, Wipro).
S & F Integral decorative LED bollard with polycarbonate diffuser square shaped with IP 65 protection suitable for 9 watts LED bulb with necessary MS base box made out of MS sheet of 2 mm thick of suitable size embedded in PCC 1:2:4 base, elecrical connections with adequate size complete as all specified and as directed. (Make: Bajaj Cat part No BGBOS 600 9W LED/ Philips Cat Part No BCP 150 LED 150 WW or other equavalent make in Wipro).
Supply and fix in repair Three core cable PVC insulated and unsheathed multistranded copper conductor of size 4.0 Sqmm complete all as specified and directed. (Make:- Polycab/Finolex/Havells or equivalent as approved by GE).
Supply and fix in repair PVC conduit pipe of 25 mm dia for grouting in wall/ garden light connection/ as per user requirement complete all as specified and directed.
Taking down Three phase energy Meter and depositing the same in E/M Store Yard and refixing after completion of wiring work after cleaning dust and clean it by soap solution complete all as specified and directed by Engineer in Charge.
Supply and laying GI pipe 25MM, light gradecomplete including taking down old unserviceable pipe all as per site requirement complete all as specified and directed by Engineer in Charge
M & L bore earthing not less than 250 mm dia 16 feet deep filled with black soil up to 7 feet from bottom complete with galvanized iron pipe 40 mm bore medium grade 3 meter long tapers at bottom & provided 12 mm holes (staggered) at 75 mm centre to centre up to 2.5 meter of length from bottom , burried directly in ground filled with 45 cm alternate layer of chemical magnisium sulphate, charcoal & salt up to ground level connected to galvanized iron strip 32 x 6mm as earthing lead up to Panel /DB BOX as per site requirement by means of bolt and nut, check nuts and washer of galvanized iron or steel including brazing work and 40mm dia light grade pipe for earth lead protection including test point terminal cover the earhing hole by PCC chamber and GI cover and testing on completion complete all as specified and directed.
Supply and fix geysers of 25 litres capacity BEE 5 star made of rust proof body to withstand pressure capacity puf insulation and inner container coated with unique polymer protective coating technology to resist corrosion from hard water, including surface and vetical type thermostat and cutout and outsmart three level safety against high temperature and pressur provided with high tech adjustable thermostat and international standards multifunction valves complete all as specified and directed.
M/s Shri Inder Construction Company
MARUDHARA CONSTRUCTION COMPANY
M/S SIDHU CONSTRUCTION COMPANY
BHAGWATI CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .