GE AF OJHAR
GE AF OJHAR
REPAIRS MAINT OF INTERNAL ELECTRFICATION AND CEILING FANS WATER SUPPLY INSTALLATION PIPE LINES AND SUMMER COOLING APPLIANCES AT CHAMERLENE AND BORGAD TOP AT AF STATION BORGAD
2022_MES_558408_1
8930/E8
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
BORGAD
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE AF OJHAR
₹50,000
Yes
30 Nov 2022
18 Oct 2022
7 Nov 2022
19 Oct 2022
5 Nov 2022
31 Oct 2022
Amount
Taking down existing copper/aluminum existing point wiring (light/fan/socket or power points) complete (fittings such as switches,ceiling roses,pendents, regulators, sockets etc to be measured saperatly) incl wooden battens and conduct etc & removing material as directed complete all as specified and as directed by Engr-in-Charge.
M&L for Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including PVC boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr-in-Charge.
All as per item no 2 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 2 but for One 5amps switch socket point independent.
Point wiring with 1.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run in and including concealed in wall/floor PVC conduit not less than 20 mm as per IS with all fittings such as bends, tee,junction boxes,etc of suitable size including 1.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge.
All as per item no 5 but for One 5 Amps socket point on same/below board with other switches.
All as per item no 5 but for One 5amps switch socket point independent.
M&L for Point wiring with 2.5 Sqmm (nominal area) PVC ( FRLS) insulated sheathed copper stranded conductor cable run including surface in wall/celling/floor in PVC casing caping as per IS with all fittings such as bends, tee, junction boxes,etc of suitable size including 2.5 Sqmm PVC(FRLS) insulated copper earth continuity conductor connected to common earth dolly and including MS/GI sunken boxes with modular inner & surface plate suitable for housing modular switches, sockets,fan regulators etc for one light/fan/call bell point controlled by one 1- way switch complete all as specified and as directed by Engr -in -Charge. Note - Cutting and making good of chasis in wall/roof/floor is included in the qtd rates.
Supply & fix in repair Modular switch one way 6 Amp,1 Module , Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supplying and fixing in repair Modular socket, 6 amps-2/3 pin combined, 2 Module, Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supplying and fixing in repair Modular switch , one way, 16 amps, one Module of Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supplying and fixing in repair Modular socket 16 amps-6 pin multipin, 2 Module of Make Legrand Mylinc/ L&T/Crabetree, complete all as specified and directed by Engineer-in-Charge
Supply & Fix in repair Ceiling rose surface type, PVC/Polycarbonate isolated body size 50x28 mm two to three terminals. Make : Anchor/Leader, complete all as specified and directed by Engineer-in-Charge
Supply and fix in repair MCB SPN 32 amp 240 V,10KA, C curve,DX3 series of Make Legrand cat part no 408617 complete all as specified & as directed by Engineer in charge.
Supply and fix in repair MCB SP 6-32 amp 240 V,10KA, C curve,DX3 series of Make Legrand cat part no 408595 complete all as specified & as directed by Engineer in charge.
Supply and fix in repair Switch piano flush button single pole one way 5 amps of Make : Anchor /Crabtree/Rio ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repairs Switch piano flush button single pole one way15 amps Make : Anchor /Rio ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Bell push flush type 5 Amps. Make : Anchor/Havells Rio.
Supply and fix in repair Modular bell push 6 Amp,1 Module , Make Anchor/ Roma/Legrand.
Supply and fix in repair Socket out let 2 in 1, 5 pin 5 Amps flush type ,complete all as specified & as directed by Engineer-In-Charge. Make : Make AnchorRoma /Legrand/Rio
Supply and fix in repair Socket out let 2 in 1, 3 pin 5 and 15 Amps combined flush type ,complete all as specified & as directed by Engineer-In-Charge. Make : Make Anchor Roma /Legrand/Rio
Supply and fix in repair Ding Dong bell AC 230 Volts single pole ,complete all as specified & as directed by Engineer-In-Charge. Make : Anchor/Press Fit
Supply and fix in repair Modular Fan regulator electronic step type 230 V 2 Module ,complete all as specified & as directed by Engineer-In-Charge. Make : Anchor/Roma/Legrand
Supply and fix in repair Fan regulator electronic step fiush type 230 V 300W ,complete all as specified & as directed by Engineer-In-Charge. Make : Anchor/Havells Rio.
Supply and fixing in repair sheet metal enclosure for DBs when MCBs to be used single pole and neutral IP 43 IK-09 protection with acrylic door, 240 volt with 200 amps rated bus bar bar 8 way of Make Legrand Cat No 607721 or equivalent model of L&T/Siemens complete all as specified & as directed by Engineer in charge.
Supply and fix in repair sheet metal enclosure for DBs when MCBs to be used single pole and neutral with acrylic door IP 43 protection, 240 volt with 200 amps rated bus bar bar 4 way of Make Legrand Cat No 607720 or equivalent model of L&T/Simens.
Supply only in repair sheet metal encloser distribution board 415volt, Vertical TPN 4 Way with and including DH 100 series MCCB 100 of legrand make as incomer and 04 Nos TP MCBs as outgoing as per IS including compact insulated bus bar and rounded neutral bar, door earthing complete double door surface /reccess mounting IP-43 protection of L&T Cat No LTVD04MGN or equivalent in Legrand / Siemens, complete all as specified and as directed by Engineer-in-Charge.
M&L in repair wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLS) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x6.0 Sqmm+1x6.0 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position, complete all as specified and directed by Engineer-In-Charge (Note: 2 run of 6.0 sq mm & 1 run of 6 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
M&L in repair wiring wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLS) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x4.0 Sqmm+1x4 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position ,complete all as specified and as directed by Engineer-In-Charge (Note: 2 run of 4.0 sq mm & 1 run of 4 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
M&L in repair wiring for circuit/ sub main wiring alongwith earth wire with the following sizes of PVC (Antitermite & ecofriendly FRLS) insulated copper conductor, single core, 1100 v grade cable in conceled/surface as required using 2x2.5 Sqmm+1x2.5 Sqmm earth wire,cables inciuding in PVC casing caping or Conduit and taking down old unserviceable submain from existing position ,complete all as specified and directed by Engineer-In-Charge.(Note: 2 run of 2.5 sq mm & 1 run of 2.5 sq mm in PVC casing and caping/conduit 20 mm diameter combined shall be measured & paid as one unit )
Supply & Fix in repair Post top lantern decorative HERITAGE LED with IP 65 RATED led post top with opel deffuser including LED 20 Watt of Make Crompton Cat Part No LPTH-20-CDL including its pedestal duly fixed in the PCC using or equivalent in Phillips/ Wipro.complete all as specified and directed by Engineer- in-charge.Note:-Warranty for light fitting should be three yrs.Note:-Warranty for light fitting should be three yrs.
Supply and fix in repair decorative ultra slim square profile linear TRIM LINEA lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 20W LED 6000K, complete with connecting accesseries duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting complete all as specified and directed by Engineer-in-Charge. MAKE : Crompton, Model No LDLSRNX-20-CDL or equivalent in Philips/ Havells.
Supply and fix in repair decorative ultra slim square profile linear TRIM LINEA lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 10W LED 6000K, complete with connecting accesseries duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting complete all as specified and directed by Engineer-in-Charge. MAKE :Crompton, Model No LDLSRNX-10-CDL or equivalent in Philips/ Crompton Greaves.
Supply and fix in repair decorative ultra slim square profile linear TRIM LINEA lighting fixture extruded polycarbonate, enviromental frendily, energy efficent ready to use pack 5W LED 6000K, complete with connecting accesseries duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting complete all as specified and directed by Engineer-in-Charge. MAKE : CROMPTON, Model No. LDLSRNX-05-CDL or equivalent in Philips/Havells.
Supply and fix in repair New generation energy saving & enviromental friendly long life versatile pressure die cast aluminium IP66 with high power road way luminaire FREEDOM NEO LED with SPD street light fitting, lamp type 45W LED 6000K , deep drawn aluminium pipe mounting attachment complete and connecting with 3 core PVC insulation PVC sheathed copper cable of size 1.5 Sqmm from junction box to street light and testing complete model No TRP-417-45-57-SL-LM-NBK Asymmetric optics of Make : Crompton or equivalent in Philips/Havells including taking down old unserviceable fitting from existing position complete all as specified & directed by Engineer-In-Charge.
Supply and fix in repair CCR127-36-57-SL-NWH 6000K Ultra modern recess mounting luminare suitable for armstrong/ grid/ POP ceiling complete with separate electronic driver & high brightness SMD LEDs, complete with connecting accesseries & Driver duly pre-wired and connecting up with 0.5 Sqmm 3 core flexible Copper cable cord from fitting, complete all as specified and directed by Engineer-in-charge. MAKE : Crompton , Model No. LCTLRN-36-CDL or equivalent in Bajaj/Crompton Greaves.
Disconnect and insulate electric supply wire and taking down carefully ceilling/ exhaust fan of any make and sweep dismantlling blades, check for repairs required,Complete all as specified & as directed by Engineer-In-Charge. ( Note: Repairs/ Replacement of spares shall be carreied under appropriate items)
Hanging/fixing only ceiling fans of any make and sweep connecting the complete with & including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from ceiling rose to fan connector and testing ,Complete all as specified & as directed by Engineer-In-Charge.( Note: The fan shall be fitted with new set of clamps, rubber shackle split pins and top and bottom nut bolts etc.)
Hanging/fixing only exhaust/cabin/wall fan of any make or sweep connecting up complete with and including provision of copper conductor cord 3 core PVC insulated and sheathed 0.5 Sqmm from celing rose to fan connector & testing ,Complete all as specified & as directed by Engineer-In-Charge.. ( Note: The fan shall be fitted with new set of washers, nuts, rubber reels, shackle etc.)
M&L for servicing opening up of fan, motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning for celling fan 1200 mm sweep,Complete all as specified & as directed by Engineer-In-Charge.
M&L for servicing opening up of fan, motor of fan, cleaning stator,rotor, cleaning of all parts greasing oiling of bushes and bearing reassembling and testing for smooth functioning for Exhaust fan 300/380/450mm sweep,Complete all as specified & as directed by Engineer-In-Charge.
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc for ceilling fan 1200 mm sweep complete all as specified and directed by Engineer-in-Charge.
M & L for removing the burnt winding and rewinding the fan with super enamelled copper winding wire of suitable gauge, insulating, putting sleeves etc for Exhaust fan of any sweep sweep complete all as specified and directed by Engineer-in-Charge.
Supply and fix bearing in repairs for replacement for ceilling fan 1200 mm sweep
Supply and fix bearing in repairs for replacement for Exhaust fan of any sweep
Supply and fix Fan capacitor for ceilling fan 1200 mm sweep
Supply and fix Fan capacitor for Exhaust fan of any sweep
1. Excavation in trenches n. exc 1.5 Mtr width and n.exc 1.5 mtr deep for foundation, laying GI pipes / Man hole, pair holes etc n.exc 10 Sq mtr on plane in hard/dense soil and getting out.
2. '-do- but in soft/loose soil
3. Returning filling in incl spreading leveling watering and well ramming in layers not exceeding 25 mm levers of soil.
4. Removing excavated materials n.exc 50m and depositing where directed at a level n.exc 1.5 above the starting point.
5. Taking up or down old rusted water tubing and connections fixed to wall floor, celing all as specifed and as dirrected for the size of 15mm bore
All as per item no-53 above but 20 mm bore pipe
All as per item no-53 above but 25 mm bore pipe
All as per item no-53 above but 40 mm bore pipe
All as per item no-53 above but 50 mm bore pipe
All as per item no-53 above but 80 mm bore pipe
Supply, laying, jointing and testing GI water tubing medium grade with all fitttings in trenches complete all as specifed and as dirrected for the size of 15mm bore
All as per item no-59 above but 20 mm bore pipe
All as per item no-59 above but 25 mm bore pipe
All as per item no-59 above but 40 mm bore pipe
All as per item no-59 above but 50 mm bore pipe
All as per item no-59 above but 80 mm bore pipe
8. Fixing only old serviceable water tubing medium grade received from item No 1 here in before and connected with new fittings of medium grade as required including cleaning, cutting, threading and fixed to wall, floor, ceiling complete all as specifed and as dirrected for the size 15mm of bore
All as per item no-65 above but 20 mm bore pipe
(All as per item no-65 above but 25 mm bore pipe
All as per item no-65 above but 40 mm bore pipe
All as per item no-65 above but 80 mm bore pipe
Repair and maintenance leakage of CI/GI pipe line of size 25 to 100 mm size including all earth work including cutting and making joints/connection in existing ling complete all as specified and as directed by engr-in-charge
. S&F bends(any type, radius and angle) Tapers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces single branch, 'y' junction, double branch, cross (all sockets or socket and spigot) collars caps and plugs upto 150 mm bore all as specified and as directed.
Supply and fix in repair Contactor for fully automatic star delta starter complete with operating coil 230 volts, 3TF52- 02-0AP0 ,2 NO+ 2 NC of Make Siemens or equivalent in L&T/Legrand complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Contactor for fully automatic star delta starter complete with operating coil 230 volts ML 2 ,2 NO+ 2 NC cat part no SS90701 of L&T or equivalent of Telemechanic,Siemens, Cutler hammer,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Relay for automatic star delta starter fully automatic suitable for up to 25 HP motor Make L&T ,complete all as specified & as directed by Engineer-In-Charge.
Supply and fix in repair Timer for automatic star delta starter fully automatic suitable for up to 25 HP motor ,complete all as specified & as directed by Engineer-In-Charge.
Supply and laying Cast iron pipes with spigot and socket ends centrifugally cast class 'B' of size 100 mm dia all as specified and as directed.
Supply and laying Cast iron pipes with spigot and socket ends centrifugally cast class 'B' of size 150 mm dia all as specified and as directed.
M & l for run lead joint suiatable for 150 mm dia spigot and socket end pipe all as specified and as directed.
M & l for run lead joint suiatable for 100 mm dia spigot and socket end pipe all as specified and as directed.
S&F in replacement of gun metal gate valve ISI marked screwed both ends of size 50 mm dia all as specified and as directed.
S&F in replacement of gun metal gate valve ISI marked screwed both ends of size 40 mm dia all as specified and as directed.
S&F in replacement of gun metal gate valve ISI marked screwed both ends of size 25 mm dia all as specified and as directed.
S&F in replacement of Bib tap cast copper alloy screwed down high pressure with crutch or butterfly handle screwed for iron pipe or for brass ferrule and fixed all as specified and as directed of size 15 mm bore all as specified and as directed.
All as per item no-83 above but 20 mm
S&F in replacement of ball valve high pressure with PVC float and flynut complete screwed for iron pipe of 20 mm bore all as specified and as directed.
S&F in replacement of ball valve high pressure with PVC float and flynut complete screwed for iron pipe of 15 mm bore all as specified and as directed.
S&F in replacement of ball valve high pressure with PVC float and flynut complete screwed for iron pipe of 25 mm bore all as specified and as directed.
S&F in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends all as specified and as dired of ssize 15 mm bore all as specified and as directed.
S&F in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends all as specified and as dired of ssize 20 mm bore all as specified and as directed.
S&F in replacement of stop valve cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends all as specified and as dired of ssize 25mm bore all as specified and as directed.
Dismantling and taking out old unserviceable CI sluice valve from existing position and S & F CI sluice valve ISI marked PN-1 both ends flanged with high tensile gun metal spindle iron wheel head check nuts etc including jointing with rubber gaskets, nuts, bolts and washer complete of following sizes all as specified and as directed of 80 mm dia Make KIRLOSKER/BIR/UPADAYAY
All as per item no-91 above but 100 MM dia
M&L for PCC 1:3:6 type C1 using 20 mm graded stone aggregate including fininshing for base of the PVC tank
S&F air release valve with two air out let of 50 mm bore with suitable fixing arrangement to CI pipe of 100mm dia complete all as specified and as directed by Engineer-in-Charge of size 100mm dia
S&F sluice valve CI 100mm dia
S&F CI pipe flanged piece of 1 mtrs of 100mm dia
S&F flanged joint along with rubbe or fibre board gasket sheet of 100mm size
S&F NRV 100mm size of length 295mm
M&L for valve chamber of size 1.5x1.5x1.35 mtrs having wall thickness of 0.26 mtrs with MS wall chamber cover made out of angle frame of size 2x2 cm angle fixed to 3mm thick MS sheet resting on 3x3 cm angle frame along with lifting and locking arrangement
All as per item no-99 above but of size 0.90x1.27 mtrs
S&F flexible pipe both end screwed brass nuts of size 15mm dia having length of 300mm suitable for hot water connection.
All as per item no-101 above but length 450mm
All as per item no-103 above but 20 HP
All as per item no-103 above but 7 HP
Supply and lay MS pipe flanged type heavy grade with all fittings laid in floor or fixed to wall ceiling etc of size 150mm
. M&L for flanged joint with rubber or fibre board gasket of size 150mm
. M&L for removal of bushes by cutting, removing vegetation removing garbage/waste from site and making approaches to valve pits and pipe lines and cleaning the surrounding area of installations , hand spraying anti grass growth chemical ( Glyson) to prevent from growth of vegetation all as specified and directed by Engr-in-charge.
. S & F in replacement brass spindle with brass check nuts of sluice valve of 100 mm
All as per item no-110 above but 80mm size.
Opening of existing sluice valve at site from top cap, cleaning of gate, greasing of spindle, replacing, nut, bolts & washers gasket, changing of gland rope of top cap in replacing 2 Nos of long nuts bolt, including painting the complete sluice valve from out side with black enameled paint of 100 MM
All as per item no-112 above but 80 mm
M&L for repair to LT panel board by using Swithc fuse unit TPN 500V 3 phase with HRC fuse suitable for internal mounting in panel of capacity 63 A
All as per item no-114 above but using Contactor ML-02
All as per item no-114 above but using Contactor ML-03
All as per item no-114 above but using Contactor ML-04
All as per item no-114 above but usingMCCB (KS 100 R) 30 A, 16 KA
All as per item no-114 above but using MCCB (KS 100 R) 75 A, 16 KA
All as per item no-114 above but using MCCB (KS 100 R) 100 A, 16 KA
All as per item no-114 above but using Ammeter DM 32 58, Make : (SENERCON/CONSERVE)
All as per item no-114 above but using VotmeterDM 32 56, Make : (SENERCON/CONSERVE)
General servicing Split AC capacity 1.5/2T ,dismantling unserviceable part of unit including cleaning of air filter,display,PCB,de-dusting of complete(indoor/outdoor) unit ,checking electrical connections & rewiring ,greasing of movable parts for getting trouble free service & making Split AC serviceable complete all as specified and directed by Engineer-In-Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor deposit to MES store yardf existing unserviceable sealed compressor of 1.5 T split air conditioner Make: Kirloskar complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new sealed unit compressor deposit to MES store yardf existing unserviceable sealed compressor of 2.0 T for split air cinditioner Make:Kirloskar complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new fan motor 1/3 Hp ,230 v for split AC Make AUE or equivalent including taking down old unserviceable fan motor from existing position complete all as specified and as directed by Engineer -in Charge.
Repairs to split AC of 1.5/2 T capacities after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling for the following complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only running capacitor for split Air conditioner 1.5 T/2 T of capacity 36/45 mfd , 7 point ,440 VAC Make Epcos ,complete all as specified and as directed by Engineer -in -Charge
Supply only starting capacitor for split Air conditioner 1.5 T/2 T of capacity 80/100 mfd 440 VAC Make Epcos, complete all as specified and as directed by Engineer -in -Charge
Supply only Relay (8500-4) (Make Annapurna) suitable for Air Conditioner mentioned above, complete all as specified & as directed by Engineer-In -Charge.
Supply only remote control switches 1.5 Ton to 3 Ton capacity split A/C of any make as existing sample complete all as specified & as directed by Engineer-In -Charge.
Supply only blower motor single phase AC 200/230 volts suitable for split model A/C of capacity 1.5 TR, complete all as specified & as directed by Engineer-In -Charge.
All as per item no 97 here-in before but for 2 TR complete all as specified & as directed by Engineer-In -Charge.
Supply only Bush with Blower shaft assy complete,1.5 Ton to 3 Ton capacity split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
Supply only Printed Circuit Board (PCB) For split A/C of make as existing sample ,complete all as specified & as directed by Engineer-In -Charge.
Repairs to Circuit of existing Printed Circuit Board (PCB) in split type AC of any make, complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair condensor coil of copper suitable for 1.5 TR/2 TR split type air conditioner including taking down old unserviceable condensor coil from existing position complete all as directed and specified by Engineer-In Charge
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 5/8 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
Supply and fix in repair copper tubes 2 mm thick for additional length required in the process of maitenance of the split air conditioners unit, with insulation of puff or TF quality of thermocole or poly urithine insulating tubes all as specified for 1/4 inch copper tubing complete all as specified & as directed by Engineer-In -Charge.
Repair to refrigerator of capacity 165/210/310 litres ,General servicing,dismantling unserviceable part of refrigerator, checking electrical connections & rewiring,cleaning of refrigerator unit ,and making refrigerator serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor deposit to MES store yardf existing unserviceable sealed compressor unit (type 1/8 ) Make-L51Q,66Q,Kirloskar,Suitable for 210 litre refrigerator of Godrej,Whirlpool, Videocon & LG complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only new sealed unit compressor deposit to MES store yardf existing unserviceable sealed compressor unit (type 1/6 ) Make-L51Q,66Q,Kirloskar,Suitable for 310 litre refrigerator of Make Godrej,Whirlpool, Videocon & LG complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Repairs to refrigerator after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only over load protector of various capacities for the cooling appliances, complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for the cooling appliances , complete all as specified & as directed by Engineer-In -Charge.
Supply only copper strainer and capillary tube suitable for refrigerator mentioned above Godrej,Whirlpool, Make : KISHCO / MB CAPIALLARYGodrej,Whirlpool, in replacement of unserviceable strainer & capillary complete all as specified & as directed by Engineer-In -Charge.
Supply only relay suitable for 1/8 and 1/6 compressor of capacities for the cooling appliances,complete all as specified and directed by Engineer in Charge
Repair to Deep freezer of capacity 265/ 320 /500 ltrs ,general servicing ,dismantling unserviceable part,checking electrical connections & rewiring,cleaning of deep freezer unit ,reassembling & making deep freezer serviceable complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor deposit to MES store yardf existing unserviceable sealed compressor unit Kirloskar or 91Q,110 of Godrej (with Relay unit) for deep freezer of capacity 265 ,320 litre complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Supply only fan motor 1/35 HP suitable for deep freezer of capacity 265/300/320 litre , fan motor AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only capillary tube and silica drier type strainer suitable for Deep Freezer 265/320/500 litre capacity (Make - Blue Star & Voltas) ,complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for the cooling appliances for deep freezer upto 500 litre capacity, complete all as specified and as directed by Engineer -In-Charge.
Supply only relay suitable for 1/8 and 1/6 compressor of capacities for Deep freezer upto 500 litre, complete all as specified and as directed by Engineer in Charge
Repairs to Deep freezer after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressere, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge.(Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
Repair to storage type water cooler of capacity 40/80 & 60/120 ltrs , general servicing ,dismantling unserviceable part, checking electrical connections,cleaning internally and externally ,cleaning of water tank,tray & water outlet scraping with emery paper filling putty wherever required and painting with one coat of red oxide and two coats of synthetic enamel paint of approved colour and reassembling marking of MES/SM No in 25 mm size alphabetes,reassembling, refitting & making water cooler serviceable, complete all as specified & as directed by Engineer-In -Charge. (Note: Repair/Replacement of the component required shall be paid under relevant item of scedule here-in-after)
Supply only new sealed unit compressor deposit to MES store yardf existing unserviceable sealed unit compressor Make : godrej 91Q,Kirloskar 4440 M,Kirloskar 446, Kirloskar 443 suitable for water cooler suitable for water cooler of capacity 40/80 litre complete all as specified & as directed by Engineer-In -Charge.
Supply only new sealed unit compressor deposit to MES store yardf existing unserviceable sealed unit compressor Make : godrej 91Q,Kirloskar 4440 M,Kirloskar 446, Kirloskar 443 suitable for water cooler of capacity 60/120 litre complete all as specified & as directed by Engineer-In -Charge.
Supply only fan motor 1/64 HP suitable for water cooler of capacity 40/ 80 lit AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only fan motor 1/32 HP suitable for water cooler of capacity 60 / 120 lit , AC single phase 230 volts and connecting up complete all as specified & as directed by Engineer-In -Charge.
Supply only thermostats with control knob of various capacities for water cooler AC single phase 230 V of make INDFOSS or Equivalent make, complete all as specified and as directed by Engineer In Charge.
Supply only over load protector of various capacities for for water cooler of capacities 60/120 litre,AC single phase 230 Volt, complete all as specified & as directed by Engineer-In -Charge.
Supply only Starting capacitor for water cooler of capacity 60 mfd Make : Epcos or equivalent , complete all as specified and as directed by Engineer -in -Charge
S&F in repair Set of Copper pencil strainer suitable for Water Cooler mentioned above including taking down old unserviceable copper pencil strainer, complete all as specified and as directed by Engineer-In-Charge. (Make - KISHCO/ MB CAPPALLARY)
Repairs to water cooler after checking the system, testing the cooling and performance, setting the thermostat, flushing the oil and refrigerent with pressure, leak testing of the system, rectification of leakage, including brazing of joints leakages in the copper tubes, capiliary etc, pressure testing of the system, putting the system on vacuum charging of suitable refrigerent(R-22 or 134a) and non freezing oil achieving desired cooling. Testing the plant for cut OFF and ON after desired cooling complete all as specified & as directed by Engineer-In -Charge. (Note- Cost of refrigerant gas and Gas charging is deemed to be included with this item )
SHRI SULAI ELECTRICALS
DIAMOND ENTERPRISES
M/s.NIKI ENTERPRISES
MAHIMA CONSTRUCTION
VINIT ASHOK KORE
Shree Sai Samarth Enterprises
United Enterprises
Datar Electrical and Engg Services
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .