Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹124.0 CrAccepted-AOC 201 3RD FLOOR A BLOCK SRI GURU TOWERS 80 FEET ROAD ANNA NAGAR MADURAI 625017 | MADURAI | TAMIL NADU | 625017 | ₹124.0 Cr Quoted ₹124.3 Cr | L1 | Accepted-AOC Being L1 Bidder |
| 2 | L2₹133 CrRejected-AOC F 18 ANSAL COMPLEX OPP JWALA HARI MARKET PASCHIM VIHAR NEW DELHI 110063 | NEW DELHI | WEST DELHI | DELHI | 110063 | ₹133 Cr | L2 | Rejected-AOC Not being L1 Bidder |
| 3 | L3₹135.9 CrRejected-AOC | ₹135.9 Cr | L3 | Rejected-AOC Not being L1 Bidder |
| 4 | L4₹138.3 CrRejected-AOC | ₹138.3 Cr | L4 | Rejected-AOC Not being L1 Bidder |
| 5 | L5₹144.7 CrRejected-AOC H NO 8 2 2 1 FLAT NO 203 SITARAMA APARTMENT OPP AXIS BANK PANJAGUTTA HYDERABAD 500 082 | HYDERABAD | TELANGANA | 500082 | ₹144.7 Cr | L5 | Rejected-AOC Not being L1 Bidder |
Tender Value
₹131 Cr
EMD Value
₹15 L
Closing Date
3 Jan 2025, 6:00 pmClosed
Chief Engineer Chennai Zone
HQ CE Chennai Zone, Island Grounds, Anna Salai, Chennai 600009
ENGINEERING, PROCUREMENT AND CONSTRUCTION (EPC) FOR PROVN OF PHASE ONE OF TWO PHASES OF KLP FOR ASC CENTRE (NORTH) BANGALORE
2024_MES_682703_1
88558/E8
Open Tender
Civil Works
912 days
Bangalore
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Garrison Engineer (Project) Bangalore
₹15 L
Yes
Chief Engineer Chennai Zone
7 Mar 2025
6 Nov 2024
8 Jan 2025
6 Nov 2024
3 Jan 2025
6 Dec 2024
16 Nov 2024
Amount
SCHEDULE 'A' PART -I (BUILDINGS / STRUCTURES) Note: This schedule is not pre-priced by MES and the Rate indicated as Rs. 0.00 under Column 5 signifies this fact only
Engineering, Procurement & Construction (EPC) of following buildings/ structures (Serial No. 1.02 to 1.04) as per GRIHA norms including all internal services and external services (except Sch 'A' Part - II to XV) as defined in Annexure -I to III complete as detailed in Scope of work and other documents of tender, complete all as specified and directed
(a) Single Living Accn for No 02 Trg BN to accomodate a total strength of 317 OR's [OR's -217 Nos & Course OR's 100 Nos ] in triple storey with baggage room & Dining hall with cook house in single storey including internal services complete – 1 Block (b) Single Living Accn for No 02 Trg BN to accoodate 1250 recruits (arranged in 4 blocks) in triple storey with baggage room & Dining hall with cook house in single storey including internal services complete – 4 Blocks (considered as one unit) (Contd.....)
(c) Single Living Accn to accomodate 480 OR's[ No 3 Trg Bn OR's - 20Nos & Course OR -150Nos, HQ Wing OR's -67Nos, CHQ OR's -35Nos & Course OR's -160Nos, ASC Records OR's -48Nos] and baggage room including internal services (Divided in 2 blocks) in triple storey including baggage room & Dining hall with cook house in single storey including internal services complete – 2 Blocks (considered as 1Unit) (d) Single Living Accn for No 03 Trg BN to accomodate 300 recruits with baggage room in triple storey & Dining hall with cook house in single storey including internal services – 1 Block (e) Office Admin Accn, Storage Accn & Education Bldg for No 1 Trg Bn in double storey including internal services with seperate LPG store– 1 Block (f) Parking space for Car and Scooter for Office administrative accn of No.1 Trg Bn- 1 Block (g) Guard House and Ancillaries, Armouries shop and Armoury in single storey including internal services – 1 Block (h) Sentry Box – 06 Nos (j) Main Receiving Station in single storey including internal services – 1 Block.
(k) Pump room with toilet and rest room in single storey including internal services – 1 Block. (l) Pump room with toilet and Lab for STP in single storey including internal services – 1 Block (m) Alarm Post – 04 Nos (n) Flag Mast – 01 No (o) Incinerator – 01 No (p) Garbage Bin – 09 Nos (q) Overhead Tank of capacity 2,00,000 Ltrs – 01 No (r) Underground sump of capacity 2,00,000 Ltrs – 01 No (s) Underground sump of capacity 1,00,000 Ltrs for treated water– 01 No (t) Sump (Capacity 70000 Ltrs) for Sewage collection near STP – 01 No (u) Garbage sorting out Shed with open hardstanding.- 01 No
Note : Schedule A - Part II to Part XI are prepriced by MES, Bidders shall insert their lumpsum amount under column 6 only.
Lumpsum price worked out by the tenderer for SITE CLEARANCE, AREA DEVELOPMENT, EXCAVATION AND EARTH WORK as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for ROAD, PATH, HARDSTANDING AND CULVERT as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for TREATED WATER SUPPLY as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for SOLAR WATER HEATER as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for COOLING APPLIANCES as listed in Schedule ‘A’ Part-XI
Note: Schedule 'A' Part - XII to Part - XVII are not pre-priced by MES
SCHEDULE 'A' PART XII - DIESEL GENERATOR SET
Supply, installation, testing and commissioning of 82.5 KVA / 66 KW,(The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), Silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of KOEL 82.5 KVA or equivalent, developing 102BHP @ 1500 RPM, Air Cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, with emission control device to control the PM within range as prescribed by NGT/ norms published vide GSR 804(E) dt 03.11.2022 of GoI and updated till date on procurement and CPCB approved acoustic enclosure suitable for ambient condition at Bangalore with integral fuel tank with battery and leads and accessories complete including required PCC foundation as per manufacturers instruction and confirming to conditions as per IS provisions complete all as specified in Item No.1 of Schedule 'A' Part -XII on Serial Page No. 136 to 140 of tender documents.
Supply, installation, testing and commissioning of 100 KVA / 80 KW,(The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), Silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 comprising of KOEL 100KVA or equivalent, developing 156BHP @ 1500 RPM, Air Cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, with emission control device to control the PM within range as prescribed by NGT/ norms published vde GSR 804(E) dt 03.11.2022 of GoI and updated till date on procurement and CPCB approved acoustic enclosure suitable for ambient condition at Bangalore with integral fuel tank with battery and leads and accessories complete iincluding required PCC foundation as per manufacturers instruction and confirming to conditions as per IS provisions complete all as specified in Item No.2 of Schedule 'A' Part -XII on Serial Page No. 140 to 144 of tender documents.
SCHEDULE 'A' PART XIII - SEWAGE TREATMENT PLANT
Design, supply, install, test & commissioning of Sewage Treatment Plant having capacity 400 KLD (at Bangalore) based on principle of aerobic attached growth non-clogging randomly Moving Bed Bio-reactor Technology (MBBR) with the DESIGN DATA mentioned in Particular specification of STP including all civil, pumping, Mechanical and electrical works in accordance with latest engineering practice complete all as specified. (Contd...)
Supply install including lowering testing and commissioning of submersible pump set 3 phase 415V 50 Hz non clog vertical type chrome steel impeller and cutter non clog to pass 40 mm particles including guide rails and 1 Ton capacity chain pulley block-01 No with non rusted steel lifting chain etc capable of delivering discharge of 560 LPM at 15 M head (5 HP) suitable for sewage pump including float switch for automatic opereation complete with all accessories complete all as specified and directed.
SCHEDULE 'A' PART XIV - ARBORICULTURE
Site cleaning including cutting and dressing of the existing vegetation (trees/bush/plants/glass, etc.,) of all types and all sizes wherever required for the approaches and the work alignment of area, etc. complete all as directed.
Supplying & stacking of good earth suitable for landscaping and lawn making free from any clods, garbage and forgein matter at site ( Soil shall be stacked before using for measurement and 20 % of the soil shall be reduced for loose stacking) 300mm from formation level complete all as specified and as directed.
Supplying & Stacking of well decomposed manure. vermicompost in required/specified ratio ( 8% of the volume shall be reduced for loose stacking complete all as specified and as directed.
Spreading of dump manure and good earth or both mixed in specified ratio and required thickness. (Cost of manure and soil to be paid separately) complete all as specified and as directed.
Supply and planting Bermuda grass on lawn on existing loose earth by overturning of earth and making it fit for lawn after duly screening and mixing with necessary organic manure and filling up earth to make the profile grade as per site requirement including spraying including application of insecticide.
Digging holes in required size 0.9m x 0.9m x 0.9m ordinary soil and refilling the same with excavated earth mixed with manure or sludge in ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed will be paid separately)
Supply & Plantation of Trees, Shrubs, Ground covers and Hedge at site including watering and removal of unserveiceable materials and maintenance of trees for 90 days or more till the trees hold ground complete the following trees/shurbs:-
Albizia Lebbeck - Siris (2.40 ht)
Givotia Rottleriformis - Indian Coral Tree(2.40 ht)
Ailanthus Excelsa - Tree of Heaven(2.40 ht)
Butea Monosperma - Flame of the Forest(2.40 ht)
Pongamia Pinnata - Honge Mara(2.40 ht)
Azadirachta India - Neem(2.40 ht)
Ficus Religiosa - Pipal(2.40 ht)
Delonix Regia - Red Gulmohar(2.40 ht)
Cassia Fistula - Golden Shower Tree(2.40 ht)
Lagerstroemia Speciosa - Pride of India(2.40 ht)
Cassia Spectabilis - Golden Cassia(2.40 ht)
Nyctanthes Arbor-Tristis - Coral Jasmine(2.40 ht)
Polyalthia Longifolia - Ashoka(2.40 ht)
Bauhinia Variegata - Orchid Tree(2.40 ht)
Michelia Champaca - Champak(2.40 ht)
Cocos Nucifera - Coconut Palm(2.40 ht)
Pavetta Indica - Paapate Gida(2.40 ht)
Maintenance of well developed plants/grass/trees provided vide SI. Items Nos 20 & 22 by engaging well experienced Gardeners minimum 10 Nos per day all as specified and as directed. The maintenance shall includes the following:- (a) Periodical de-weeding of unwanted vegetation growth around the plants/lawn area. (b) Watering all the trees/plants/lawn areas as required for proper growth, (c) Periodical Lawn mowing, (d) Periodical prunning the Shrubs and (e) Treating the trees/plants/grass and soil with required quantity of approved manure, pesticides and fertilizers including necessary topping of red earth. (f) Replacement of dried/dead plants/grass/trees
Note:- (i) The works covered under this item shall immediately commence from the next date of certified date of completion of Phase I works issued by GE and shall run for a period of 02 years. (ii) The rate quoted shall be deemed to include the cost of manure, pesticide and fertilizers, cost of plants required for replacement of dried/dead plants/grass/trees and cost of red earth for topping up. (iii) Water shall be supplied free of cost for maintenance only of well developed plants/ grass/ trees provided vide SI Item Nos 20 & 22. However the contractor has to make necessary arrangements for irrigation from the water point given by suitable method at site without any extra cost to the department.
SCHEDULE 'A' PART XV (MISCELLANEOUS ITEMS)
ROAD, PATH, HARDSTANDING & CULVERT
Manufacturing, supplying and fixing of Retro-Reflectrorised rectangular Direction sign Board as per IRC: 67 made of High Intensity Prismatic reflective sheeting Type IV vide clause 8001.3, fixed over Aluminium composite material 3.20 mm thick 180cmx120cm Rectangular size fixed on an angle iron frame of size 75mmx75mmx6mm including 2 Nos. Post embedded in PCC complete all as specified and as directed
Supply and fixing Speed Bumps made of ABS material, yellow and Black colour, Size per piece 350 x 250 x 50 mm tapering to top, Fixed using Anchor bolts and Epoxy mortar grout complete all as specified and as directed
Supply and fixing Guide Post and post made of ABS plastic body having four nos. highly reflective round reflectors of 100 mm dia & 4 nos of rectangular reflectors of 70x23 mm size (2 Nos. each side), duly inserted into MS pipe 46 mm dia & 1000 mm long duly powder coated complete all as specified and as directed
Supply and fixing Safety traffic convex mirror of size 1000mm dia unbbreakable having clear and definite mirror image with upper case coller provided with suitable clamps & nut bolts. The complete set shall be fixed on MS Pipe 65mm N.B. 2.0 mtr duly powder coated painted in sign, destination sign, 800mm x 600mm complete all as specified and as directed
SEWAGE DISPOSAL
Supply and laying 170mm internal dia double walled corrugated HDPE SN-8 pipes confirming to IS:14930 Part-2/IS:16025 Par-24, including all necessary specials, cutting and jointing all as specified and as directed.
Supply and laying 200mm internal dia double walled corrugated HDPE SN-8 pipes confirming to IS:14930 Part-2/IS:16025 Par-24, including all necessary specials, cutting and jointing all as specified and as directed.
Supply and laying 300mm internal dia double walled corrugated HDPE SN-8 pipes confirming to IS:14930 Part-2/IS:16025 Par-24, including all necessary specials, cutting and jointing all as specified and as directed.
RAIN WATER HARVESTING
Supply and spreading of coarse sand (1.5 to 2mm grain size) in rain water recharge pit complete all as specified and as directed.
Supply and spreading of gravel (5 to 10mm size) in rain water recharge pit complete all as specified and as directed.
Supply and spreading of gravel (3 to 6mm size) in rain water recharge pit complete all as specified and as directed.
Supply and spreading of loose boulders (5 to 20cm size) in rain water recharge pit complete all as specified and as directed.
Supply and fix perforated PVC pipe of dia 150mm complete all as specified and as directed.
Supply and fix Geo-textile fabric, 400 GSM, around the perforated PVC pipe complete all as specified and as directed
Supply and fix Circular shape 560 mm dia precast R.C.C. manhole cover with frame, capable of withstanding 35MT (EHD-35) complete all as specified and as directed
EXTERNAL WATER SUPPLY
Supply, lay and testing Ductile Iron pipes 200 mm dia (8") with spigot and socket ends cast class K-9 confirming to IS 8329 with inside surface of centrifugally cast cement mortar lined suitable for and including rubber tyton joint bore , in trenches , on the ground or on supports above ground level complete all as specified
Supply, lay and testing Ductile Iron pipes 150 mm dia (6") with spigot and socket ends cast class K-9 confirming to IS 8329 with inside surface of centrifugally cast cement mortar lined suitable for and including rubber tyton joint bore, in trenches, on the ground or on supports above ground level complete all as specified
Supply, lay and testing Ductile Iron pipes 100 mm dia (4") with spigot and socket ends cast class K-9 confirming to IS 8329 with inside surface of centrifugally cast cement mortar lined suitable for and including rubber tyton joint, fittings like bend, tee, branch etc for laying level or to falls , in trenches , on the ground or on supports above ground level complete all as specified
Supply, lay and testing ductile iron pipes 200 mm dia (8") bore with Flanged ends at both side with suitable thickness of flanged class K-9 confirming to IS 8329 with inside surface of centrifugally cast cement mortar lined suitable for & including leather gasket joint, fittings etc for laying level or to falls , in trenches , on the ground or on supports above ground level complete all as specified.
Supply ,install , test and commission of Centrifugal electrically driven self priming monoblock pump set with cast iron impeller capable of pumping 28 LPS at 48 Mtr head, squirrel cage TEFC induction motor 3 phase, 415V AC, 50 Hz, Min Efficiency Level IE4, coupled on common base channel including necessary PCC foundarion works, nuts and bolts, copper cable from starter to motor through PVC flexible pipe , suitable size of suction pipe as per manufacutrer not less than 20 feet or as reqd at site , air release valve, foot valve on suction side complete all as directed and specified Make: KDS 3068+ of Kirloskar/Equivalent
Construction of valve chamber of size 900 x 900 mm (Internal size) 900 mm deep for 150mm dia sluice valve with 200mm thick PCC block masonary walls built in CM 1:4 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 40 mm x 40 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock 65mm, brass and keys (Godrej/Shell), MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar of suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears:-
(a) Bus bar chamber with electrolytic aluminium bus bar 300 Amp capacity for 3 phase - 01 set (b) MCCB 4 pole adjustable thermal/magnetic setting, 160 A, 415 V ,25 KA- 01 Nos (c) MCCB 4P, 63 A, 415 V ,16 KA- 03 Nos (outgoing) (d) Fully automatic star delta starter suitable for 30 HP Pumping Set- 03 Nos (e) MCB SPN 6-32 Amp 10 KA -01 Nos (f) Single phase preventer- 03 Nos
EXTERNAL ELECTRIC SUPPLY
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar of suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears: - (Main LT panel for SS3)
(i) Aluminium bus bar 3 phase & neutral of capacity 1500 Amps (ii) ACB 4 Pole 1000 Amps 50 KA-01 No ( Incoming) (iii) ACB 4 Pole 800 Amps 50 KA-01 No ( Outgoing for sub panel 1) (iv) MCCB 4 Pole 400 Amps 50 KA-01 No (Outgoing for APFC) (v) MCCB 4 Pole 63 Amps 35 KA-03 No (Outgoing for Admin blck-01, Education Bldg-01, spare-01) (vi) MCB TPN 20 Amps 10 KA - 01 Nos ( Outgoing For Gd house) (vii) MCB SP 10 Amps 10 KA - 01 Nos ( Outgoing For Street Light ) (viii) Timer switch three phase with contactor 16/20 amp - 01 Nos
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar of suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears: - (Sub panel No. 01 for SS3)
(i) Aluminium bus bar 3 phase & neutral of capacity 1200 Amps (ii) ACB 4 Pole 800 Amps 50 KA-01 No ( Incoming) (iii) MCCB 4 Pole 160 Amps 36 KA-05 No ( Outgoing for Single living Bldg No 9,10a,10c,12 and 01 spare) (iv) MCCB 4 pole 40 Amps 16 KA-03 No (Outgoing for cook house Bldg No 15,16a,10c) (v) MCCB 4 pole 63 Amps 16 KA-01 No ( Outgoing for cook house Bldg No 18 ) (vi) MCB TPN 16 Amps 16 KA - 02 Nos ( Outgoing For Hight mast light-01 no and street light -01 no) (vii) Timer switch three phase with contactor 16/20 amp - 01 Nos
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar of suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears: - (Main LT panel for SS4)
(i) Aluminium bus bar 3 phase & neutral of capacity 1200 Amps (ii) ACB 4 Pole 800 Amps 50 KA-01 No ( Incoming) (iii) MCCB 4 Pole 630 Amps 50 KA-01 No ( Outgoing for Sub panel 1) (iv) MCCB 4 Pole 400 Amps 50 KA-01 No (Outgoing for APFC) (v) MCCB 4 Pole 160 Amps 36 KA-03 No ( Outgoing for Single living Bldg No 10b,10d,and 01 spare) (vi) MCCB 4 Pole 100 Amps 16 KA-01 No ( Outgoing forSTP) (vii) MCCB 4pole 40 Amps 16 KA-02 No ( Outgoing for cook house Bldg No 16b, 16d) (viii) MCB SP 10 Amps 10 KA - 01 Nos ( Outgoing For Street Light ) (ix) Timer switch three phase with contactor 16/20 amp - 01 Nos
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar of suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears: - (Sub panel No. 01 for SS4)
(i) Aluminium bus bar 3 phase & neutral of capacity 1000 Amps (ii) MCCB 4 Pole 630 Amps 50 KA-01 No ( Incoming) (iii) MCCB 4 Pole 200 Amps 36 KA-02 No ( Outgoing for Single living Bldg No 11b and 01 spare) (iv) MCCB 4 Pole 100 Amps 16 KA-01 No ( Outgoing for Single living Bldg No 11a) (v)MCCB 4pole 40 Amps 16 KA-02 No (Outgoing for cook house Bldg No 17a,17b) (vi) MCB TPN 16 Amps 10 KA - 01 Nos ( Outgoing For Hight mast light) (viii) MCB SP 10 Amps 10 KA - 01 Nos ( Outgoing For Street Light ) (vii) Timer switch three phase with contactor 16/20 amp - 01 Nos
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on 440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral aluminium bus bar of suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears: - (Main LT panel for Pump house)
(i) Aluminium bus bar 3 phase & neutral of capacity 300 Amps (ii) MCCB 4 Pole 200 Amps 36 KA-01 No (Incoming) (iii) MCCB 4 Pole 160 Amps 36 KA-02 No (Outgoing for Motor panel- 01 no and 01 spare) (iv) MCCB 4 Pole 100 Amps 16 KA-01 No (Outgoing for APFC panel ) (v) Timer switch three phase with contactor 16/20 amp - 01 Nos
Supply, installation, testing and commissioning of free standing Indoor HT VCB Panel switchboard 12 kV, 3 Phase, 50 Hz , AC system with posibility of future extension at one side and complete with VCB, air insulated copper bus bar rated for suitable capacity of 26.3 kA for 3 Sec. comprising of Incomers & Outgoings Vacuum Circuit Breakers (01 Incomer + 03 out going feeders ), draw out type with 230 Volts, 50 Hz, single phase motor charged spring closing mechanism ( 230V AC ), dust and vermin proof, fully interlocked, vertical isolation, indoor truck type with trip-free mechanism with mechanical ON/OFF indicators, earthing terminals, automatic safety shutters, insulated 3 Pole, copper busbar of adequate size, CT, PT, Numerical Relays ( arc sensors to be provided for Incomer) , Metering, Indication, power and control wiring, interconnections, earthing truck, sheet steel construction not less than 2.5 mm thickness for load bearing section and not less than 2 mm thickness for non-load bearing conforming to IS/IEC 62271-200 & IS/IEC 62271-100 (with latest amendment) complete with following accessories:-
(A) INCOMER : (a) 01 No. 630A horizontal drawout type vacuum circuit breaker in 11 kV metal clad floor mounting panel complete with following manually and motor operated spring charge - manually and electrically operated ; position limit switches with minimum 6 NO + 6NC breaker auxiliary contacts. (b) Current transformer Cast resin type 11 KV , CT ratio: 600-300/5/5A Core1: Class 1.0 for metering , Core 2: Class 5P10 7.5VA burden for protection - 3 Nos. (c) Line Potential transformer Cast resin type 11kV/√3/110V/√3/110V/√3 Core1: Class 1.0 , Core 2: Class 3P 25VA burden and HT fuse at the primary and and MCB at the secondary of the PT - 3 Nos. (d) Numerical Relay:- Protection arrangements for the breaker shall comprise of O/C, S/C,E/F with Modbus communication protocol numerical type complete with master trip , anti pumping relay etc with suitable indiactaion lamps, TNC switch, Local / Remote switch & necessary accessories. (e) Digital Multifunction meter with RS485 communication Cl 1.0 Numerical Relay ( 50,51,50N,51N,27,59,95) with IEC 61850 with arc protection - 1 No.
(B) OUTGOING ( CABLE FEEDERS ) : (a) 03 Nos 630A horizontal drawout type vacuum circuit breaker in 11 kV metal clad floor mounting panel complete with following manually and motor operated spring charge - manually and electrically operated ; position limit switches with minimum 6 NO + 6NC breaker auxiliary contacts. (b) Current transformer Cast resin type 11 KV , CT ratio: 100-50/5/5A Core1: Class 1.0 for metering , Core 2: Class 5P10 7.5VA burden for protection - 3 Nos. (c) Numerical Relay:- Protection arrangements for the breaker shall comprise of O/C, S/C,E/F with Modbus communication protocol numerical type Siemens / ABB / Schneider complete with master trip , anti pumping relay etc with suitable indiactaion lamps, TNC switch, Local / Remote switch & necessary accessories . (d) Digital Multifunction meter with RS485 communication Cl 1.0 - 1 No. (e) Numerical Relay ( 50,51,50N,51N,95) with IEC 61850 - 1no
(C) Additional accessories to be supplied : (a) 1 No . Busbar earthing truck - 630A non fault making type (b) 1 No . Cable earthing truck - 630A non fault making type (c) 2 Nos Rack in rackout handle
NOTE :- (i) Vacuum interrupter bottle , Vacuum Circuit breaker, Main Numerical Relay & HT Panel shall be of same OEM make in whose name type test reports will be submitted. (ii) Vacuum circuit breaker & HT panel shall be of the same make only. (iii) HT Panels to be manufactured, tested, dispatched from OEM factory in whose name type test reports shall be furnished. Panels manufactured by system integrators/ franchise partners of OEM are not acceptable. (iv) Switchgear panel shall be type tested for internal arc AFLR 25kA for 1 sec for all 3HT compartments. i.e., Busbar, CB & Cable compartments. Individual Type test reports with results clearly mentioned shall be furnished. (v) Panel construction shall be made up of Aluzinc material for higher strength & also to avoid effects of corrosion /rusting. CRCA sheet can be used for front doors & end cover only. (vi) Vacuum Circuit breaker shall comply to Electrical Endurance – E2 class, Mechanical Operations - M2 class, Capacitive Switching duty - C2 class in conformance to IEC 62271-100. Make: ABB ( Leangear ZN1) / Schneider ( PIX ) / Siemens ( NX Air )
Supply, fixing testing and commissioning of 3 way out door type RMU (Ring Main Unit) of 2 OD + 1 VL, extensible type consisting of 2 Nos load break switch of 630 Amps, 01 No 630 Amps VCB and metering panel with protection and metering CTs, Potential Transformer, sheet steel construction not less than 2.0 mm thickness, stainless steel tank construction not less than 2.5 mm thickness conforming to IS/IEC 62271-200 & IS/IEC 62271-100 (with latest amendment) complete complete with & including PCC foundation for mounting and as per followings specifications :-
(i) Type - Out door type motorized 04 module RMU (ii) Operating Voltage - 11 KV (iii) Rated Frequency - 50 HZ (iv) Rated start time current - 21 KA (v) Operation - Motorized (vi) VCB - 630 Amp (Fixed type) (vii) Load Break System - 630 Amp (Fixed type) (viii) Protection - Self powered O/C and E/F Relay protection with suitable protector CTs for distribution transformer. (ix) Bus Bar - 630 Amps (x) Metering- Ring core CT 400-200/1A, 2.5 VA, CL 0.5 (xi) Class of protection - (a) IP 67 for SF6 Gas Tank (SS) (b) IP 54 for outdoor enclosure Make - Schneider / ABB / Siemens or equivalent
Supply and fixing LED All in One solar street light fitting 36 watt luminiare output (120 Lumen/Watt) in built Lithium Ferro Phosphate battery 12.8V & 27 Ah, Mono Crystalline solar panel 60W &18V, PIR Sensor with Colour Temperature 6000K, MPPT charge controller with dusk down sensor, 2 days autonomy with dimming profile complete incuding galvanised Octagonal steel pole of 6 mtr length, 3 mm thickness, 70 mm top & 130 mm bottom with base plate 200x200x12 mm and 64 micron, M16x600/EN 8 grade foundation bolt, 1 mtr arm for light fixing & PCC foundation complete all as specified & directed.
Supply and fix Cable Junction Box Thermoplastic body IP 66 , size 200x181x98mm suitable for helogen free and weather proof for out door installation with metric knockout for cable entry suitable for cable size 10-25 sqmm including 01 No SP MCB single pole of capacity 5 to 30 Amps 240 Volts and connecting up complete, MS clamp fabricated from 25x3mm MS flat iron with bolt all specified and as directed. Make: Hensil/Neptune/sintex
Supply & Fix Cable route indicator, oval shaped 200mmx150mmx6mm cast iron precast with engraving "LT/HT MES CABLE", duly painted and embedded in 1:3:6 PCC type C1 including necessary excavation and removal of soil complete all as specified and as directed.
Material and labour for Trenchless boring horizontaly underneath the existing bituminous macadam road/drain crosswise by adopting trenchless tunneling work through specified pipe jacking method by erecting the equipment to true to the alignment and gradient by hydraulic pipe jacking technique complete including tunneling, excavation in any type of soils, hard rock etc., including provision of HDPE pipe heavy duty of size 110mm bore as casing pipe with all fittings and inserting it into the trenchless boring to carry LT UG cables of size upto 300 Sqmm and necessary conveyance charges of machinery and other required materials in co-ordination with the concerned authorities etc., complete all as specified and as directed. Note: (i) LT UG cable shall be measured and paid separately under relevant item and Schedule (ii) The unit rate quoted shall be deemed to include the cost of 110mm dia heavy duty HDPE pipe, Earthwork and excavation in any type of soil for erecting the equipment.
Construction of Transformer foundation of suitable size for 500 KVA transformer 1.50Mtr (above GL) and 1.0 Mtr (below GL) including excavation in trenches in hard/dense soil, PCC 1:4:8 type D2 bed concrete, RR stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick including PCC coping and RFR , removal of surplus soil and three coats white wash etc complete all as specified
Construction of Transformer foundation of suitable size for 100 KVA transformer 1.50Mtr (above GL) and 1.0 Mtr (below GL) including excavation in trenches in hard/dense soil, PCC 1:4:8 type D2 bed concrete, RR stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick including PCC coping and RFR , removal of surplus soil and three coats white wash etc complete all as specified
TREATED WATER SUPPLY
Supply, installation, testing and commissioning of Treated water pump capable of 14.6 LPS discharge at 32 m head (KDS 1040+ of Kirloskar or equivalent) having CI casing & bronze impeller complete with all accessories, motor suitable for 415±10% V, 3- Ph, 50 Hz AC supply, pressure gauge with isolation cock, foot valve, isolation valve, NRV on delivery line, strainer at suction. mechanical seal, suitable vibration pads, Pressure gauge, drain pipe with valve etc. complete all as specified and directed.
Supply and fixing of Submersible cable, PVC insulated and sheathed flat 3 core, 4 Sq mm, 1100 Volts grade with multi stranded copper conductors from starter to submersible pump set complete all as specified and as directed
Supply install test and comissioning of centrifugal electric driven self priming monoblock pumpset with cast iron impeller capable of pumping 510 LPM at 20Mtr Head Sqireel cage TEFC induction motor 3 Phase 415 V,AC 50 Hz suitable for delivery 510 LPM at 20M Head coupled on common base channel including necessary PCC foundation works nuts bolts copper cable from starter to motor through PVC flexible pipe suitable size of suction pipe as per manufacturer not less than 20 Feet or as required at site air release valve foot valve on suction side complete all as directed and specified
Construction of valve chamber of size 900 x 900 mm (Internal size) 450 mm deep for 63mm dia PP-R gate valve with 200mm thick PCC block masonary walls built in CM 1:4 over 100 mm thick foundation concrete in PCC 1:4:8 type D2, (Using 40 mm graded coarse aggregate) with 100 mm off set, 15mm thick complete internal plaster and external plaster up to a depth of 15 cm below GL in CM (1:6), 3 mm thick MS sheet cover, double door welded to 40 mm x 40 mm x 6mm MS angle frame fixed with hold fasts in PCC 1:2:4 type B1 coping 50 mm thick in PCC (1:2:4) type B-1, 20mm x 6mm flat iron hinges with locking arrangement including lock 65mm, brass and keys (Godrej/Shell), MS handles and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer to all steel surfaces including excavation & earth work in any type of soil /soft disintegrated rock and disposal of surplus soil to a distance not exceeding 50 Mtr complete all as specified and directed
COOLING APPLIANCES
Supply and fix Refrigerator electrical driven Double door (single phase) capacity min 330 ltrs BEE 5 star rated suitable for operation on 230v 50HZ AC all as Specified and directed.
Supply and fix Refrigerator electrical driven Double door (single phase) capacity Min 300 ltrs BEE 5 star rated suitable for operation on 230v 50HZ AC all as Specified and directed.
Supply and fix Refrigerator electrical driven Single door (single phase) capacity Min 185 ltrs BEE 5 star rated suitable for operation on 230v 50HZ AC all as Specified and directed.
Supply and fix Voltage stabilizer for automatic operation, Single Phase naturally air cooled indoor type and designed for input variation between 170Volts to 250Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and of 1KVA capacity complete all as specified and as directed
Supply and fix Voltage stabilizer for automatic operation, Single Phase naturally air cooled indoor type and designed for input variation between 170Volts to 250Volts with output voltage stabilized at 230Volts with accuracy of ± 2.5% and of 5KVA capacity complete all as specified and as directed
EARTHING
Earthing complete with Galvanised steel earth plate electrode 600x600x 6mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to GI earth strip of 32 mm x 6 mm size by means of bolts, nuts and washers protected by GI tubing light grade 40 mm dia upto Test point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus soil and providing charcoal dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI strip length up to 7.50M will be measured as one unit)
Earthing complete with Galvanised steel earth plate electrode 600x600x 6mm buried directly in the ground vertically to depth not less than 3 Mtr below the ground level with the top edge of earth plate, depth not less than 2.25 Mtr below the ground level connected to GI earth wire 4 mm size by means of bolts, nuts and washers protected by GI tubing light grade 15 mm dia up to Test point 20 mm dia watering pipe with funnel & wire mesh, PCC pit in PCC 1:2:4 using 20 mm stone aggregates chamber 40 mm thick RCC cover slab (1:2:4) type B-1 using 20 mm graded stone aggregates complete all as specified and shown in electrical plate No.3 of SSR Part-I including earth work in any type of soil ,removal of surplus soil and providing charcoal dust & salt layers all around the earth plate upto 15 cm all as required specified & directed by engr in charge Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI wire length up to 7.50M will be measured as one unit)
SCHEDULE 'A' PART XVI - MANNING & OPERATION OF 400 KLD STP ( DURING DEFECT LIABILITY PERIOD)
Manning and operation, Routine maintenance of Sewage Treatment Plant 400KLD capacity supplied, installed and commissioned in the contract along with DG Sets and including all E/M inventory by carrying out round the clock operation & maintainence including all Sundays and public holidays by employing the man power and shift timings as mentioned below for operation of plant daily including supply of water treatment chemicals (i.e. Bio septic clean powder, sodium Hypochloride, Dap enzime, Calcium Hypo Chloride and Bleaching powder etc.,), Activated carbon Filter media (ACF). Activated Sand filter media (ASF), MBBR fluidized bio-media, Bacteria culture and other consumables required for smooth running of STP Plant and provision of reliever for weekly off and carrying out daily, weekly, monthly, quarterly & half yearly maintenance etc., complete during defects liability period all as specified and as directed. (a) Man power to be employed per day:- FGM(SK) Operator - 03 Nos. (1 person per shift of 8 hours)
All as per Item No.70.00 here-in-before but after completion of Serial item No. 70.00
All as per Item No.70.00 here-in-before but after completion of Serial item No. 71.00
SCHEDULE 'A' PART XVII - MANNING & OPERATION OF 400 KLD STP (AFTER DEFECT LIABILITY PERIOD)
Manning and operation, Routine maintenance of Sewage Treatment Plant 400KLD capacity supplied, installed and commissioned in the contract along with DG Sets and including all E/M inventory by carrying out round the clock operation & maintainence including all Sundays and public holidays by employing the man power and shift timings as mentioned below for operation of plant daily including supply of water treatment chemicals (i.e. Bio septic clean powder, sodium Hypochloride, Dap enzime, Calcium Hypo Chloride and Bleaching powder etc.,), Activated carbon Filter media (ACF). Activated Sand filter media (ASF), MBBR fluidized bio-media, Bacteria culture and other consumables required for smooth running of STP Plant and provision of reliever for weekly off and carrying out daily, weekly, monthly, quarterly & half yearly maintenance etc., complete after completiton of defects liability period all as specified and as directed. (a) Man power to be employed per day:- FGM(SK) Operator - 03 Nos. (1 person per shift of 8 hours)
All as per Item No. 73.00 here-in-before but after completion of Serial item No. 73.00
All as per Item No. 73.00 here-in-before but after completion of Serial item No. 74.00
All as per Item No. 73.00 here-in-before but after completion of Serial item No. 75.00
City Promoter and Buildwell Pvt. Ltd. (BID ID -3199933)
SHRE GURMUKHDAS CONTRACTOR PVT. LTD. (BID ID -3199568)
KBR Infratech Limited (BID ID -3198928)
SHRADHA SABOORI PROJECTS INDIA PRIVATE LIMITED (BID ID -3190832)
G R M CONSTRUCTIONS (BID ID -3191646)
Som Projects Pvt. Ltd. (BID ID -3199967)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid