Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹69.9 L
Closing Date
9 Sept 2024, 2:30 pmClosed
Chief Engineer (D and R)
Office of Chief Engineer (D and R)
DEVELOPMENT OF DISTRIBUTION INFRASTRUCTURE AT KOHIMA (PART-II) DISTRICT OF NAGALAND UNDER THE REVAMPED REFORMS-BASED AND RESULTS-LINKED, DISTRIBUTION SECTOR SCHEME-RDSS
2024_DP_679_1
CEL/DnR/RDSS/LR/NIT/PKG-KMA (PART-II)/73
Open Tender
Electrical Works
730 days
Nagaland
Refer RFB
3 documents required · 3 mandatory
₹25,000
Chief Engineer (D and R)
₹69.9 L
9 Sept 2024
3 Sept 2024
9 Sept 2024
3 Sept 2024
9 Sept 2024
6 Sept 2024
Amount
A. 11 KV INFRA FOR DOWNLINKING WITH NERPSIP SCHEME
(A-1) Supply of Materials 11 kV Line with MINK conductor (10 M GI STP SP-45 Pole)
GI Steel Tubular Pole SP-45(10M)
GI Channel 100x50x5 mm, 3.5 M Length weighing approx 9.60Kg/Mtr
GI Angle 65X65X6 mm, 1.5 M Length weighing approx 5.8 Kg/Mtr for 1Pole (SP) Brackets
GI Angle 65X65X6 mm , 5 M Length weighing approx 5.8 Kg/Mtr for 2Pole (DP) Bracing -
GI Angle 65X65X6 mm, 5M Length weighing approx 5.8 Kg/Mtr for Road Crossing
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 45 ST Pole
dia - 115 mm (Top Section ) weighing 1.68 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 45 ST Pole
dia - 115 mm (Top section) weighing 0.84 kg each for SP Brackets
dia - 140 mm (Middle section ) weighing 0.98 kg each for DP Bracing & Crossing
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 250mm ((5/8"x10") each weighing 0.50 kg
16 mm dia x 150mm ((5/8"x6") each weighing 0.348 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length, guy insulator complete set
GI Pipe 2", 10 mtr length for Pole Earthing
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
G. I. wire , 8 SWG for Guarding weighing 0.131 Kg/Mtr
G. I. wire , 6 SWG for Pole earthing weighing 0.192 kg /mtr
11 kV Polymer Disc insulator B&S (70KN)
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
ACSR Mink Conductor
Tension Claim for ACSR Mink
PG Claim for ACSR Mink
11kV Danger plate
GI Barbed wire 12SWG for Anti Climbing device weighing 0.17kg/Mtr.
(A-2) Supply of Materials 11 kV Line with HARE conductor (12 M GI STP SP-66 Pole)
GI Steel Tubular Pole SP-66 (12M)
GI Channel 100x50x5 mm, 3.5 M Length weighing approx 9.60Kg/Mtr
GI Angle 65X65X6 mm, 1.5 M Length weighing approx 5.8 Kg/Mtr for 1Pole (SP) Brackets
GI Angle 65X65X6 mm , 5 M Length weighing approx 5.8 Kg/Mtr for 2Pole (DP) Bracing -
GI Angle 65X65X6 mm, 5M Length weighing approx 5.8 Kg/Mtr for Road Crossing
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 66 ST Pole
Dia - 166 mm (Top Section ) weighing 2.24 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 66 ST Pole
Dia - 166 mm (Top section) weighing 1.12 kg each for SP Brackets
Dia - 194 mm (Middle section ) weighing 1.28 kg each for DP Bracing & Crossing
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 250mm ((5/8"x10") each weighing 0.50 kg
16 mm dia x 150mm ((5/8"x6") each weighing 0.348 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length, guy insulator complete set
GI Pipe 2", 10 mtr length for Pole Earthing
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
G. I. wire , 8 SWG for Guarding weighing 0.131 Kg/Mtr
G. I. wire , 6 SWG for Pole earthing weighing 0.192 kg /mtr
11 kV Polymer Disc insulator B&S (70KN)
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
ACSR Hare Conductor
Tension Claim for ACSR Hare
PG Claim for ACSR Hare
11kV Danger plate
GI Barbed wire 12SWG for Anti Climbing device weighing 0.17kg/Mtr.
(A-3) Supply of Materials 11 kV Line with Weasel conductor (9.5 M GI STP SP-35 Pole)
GI Steel Tubular Pole SP-35(9.5M)
GI Channel 100x50x5 mm, 3.5 M Length weighing approx 9.60Kg/Mtr
GI Angle 65X65X6 mm, 1.5 M Length weighing approx 5.8 Kg/Mtr for 1Pole (SP) Brackets
GI Angle 65X65X6 mm , 5 M Length weighing approx 5.8 Kg/Mtr for 2Pole (DP) Bracing -
GI Angle 65X65X6 mm, 5M Length weighing approx 5.8 Kg/Mtr for Road Crossing
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top Section ) weighing 1.4 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top section) weighing 0.7 kg each for SP Brackets
dia - 115 mm (Middle section ) weighing 0.84 kg each for DP Bracing & Crossing
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 250mm ((5/8"x10") each weighing 0.50 kg
16 mm dia x 150mm ((5/8"x6") each weighing 0.348 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length, guy insulator complete set
GI Pipe 2", 3 mtr length for Pole Earthing
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
G. I. wire , 8 SWG for Guarding weighing 0.131 Kg/Mtr
G. I. wire , 6 SWG for Pole earthing weighing 0.192 kg /mtr
11 kV Polymer Disc insulator B&S (70KN)
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
ACSR Weasel Conductor
Tension Claim for ACSR Weasel
PG Claim for ACSR Weasel
11kV Danger plate
GI Barbed wire 12SWG for Anti Climbing device weighing 0.17kg/Mtr.
B. 11 KV RECONDUCTORING
(B-1) Supply of Materials for 11kV Line Reconductoring with MINK Conductor (60Sq mm) ( 10 M GI STP SP-45 Pole)
GI Steel Tubular Pole SP-45(10M)
GI Channel 100x50x5 mm, 3.5 M Length weighing approx 9.60Kg/Mtr
GI Angle 65X65X6 mm, 1.5 M Length weighing approx 5.8 Kg/Mtr for 1Pole (SP) Brackets
GI Angle 65X65X6 mm , 5 M Length weighing approx 5.8 Kg/Mtr for 2Pole (DP) Bracing -
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 45 ST Pole
Dia - 115 mm (Top Section ) weighing 1.68 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 45 ST Pole
Dia - 115 mm (Top section) weighing 0.84 kg each for SP Brackets
Dia - 140 mm (Middle section ) weighing 0.98 kg each for DP Bracing & Crossing
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 250mm ((5/8"x10") each weighing 0.50 kg
16 mm dia x 150mm ((5/8"x6") each weighing 0.348 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length, guy insulator complete set
GI Pipe 2", 10 mtr length for Pole Earthing
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
G. I. wire , 6 SWG for Pole earthing weighing 0.192 kg /mtr
11 kV Polymer Disc insulator B&S (70KN)
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
ACSR Mink Conductor
Tension Clamp for ACSR Mink
PG Clamp for ACSR Mink
11kV Danger plate
GI Barbed wire 12SWG for Anti Climbing device weighing 0.17kg/Mtr.
(B-2) Supply of Materials for 11kV Line Reconductoring with HARE Conductor ( 12 M GI STP SP-66 Pole)
GI Steel Tubular Pole SP-66 (12M)
GI Channel 100x50x5 mm, 3.5 M Length weighing approx 9.60Kg/Mtr
GI Angle 65X65X6 mm, 1.5 M Length weighing approx 5.8 Kg/Mtr for 1Pole (SP) Brackets
GI Angle 65X65X6 mm , 5 M Length weighing approx 5.8 Kg/Mtr for 2Pole (DP) Bracing -
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 66 ST Pole
Dia - 166 mm (Top Section ) weighing 2.24 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 66 ST Pole
Dia - 166 mm (Top section) weighing 1.12 kg each for SP Brackets
Dia - 194 mm (Middle section ) weighing 1.28 kg each for DP Bracing & Crossing
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 250mm ((5/8"x10") each weighing 0.50 kg
16 mm dia x 150mm ((5/8"x6") each weighing 0.348 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length, guy insulator complete set
GI Pipe 2", 10 mtr length for Pole Earthing
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
G. I. wire , 6 SWG for Pole earthing weighing 0.192 kg /mtr
11 kV Polymer Disc insulator B&S (70KN)
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
ACSR Hare Conductor
Tension Clamp for ACSR Hare
PG Clamp for ACSR Hare
11kV Danger plate
GI Barbed wire 12SWG for Anti Climbing device weighing 0.17kg/Mtr.
(B-3) Supply of Materials for 11kV Line Reconductoring with WEASEL Conductor ( 9.5 M GI STP SP-35 Pole)
GI Steel Tubular Pole SP-35(9.5M)
GI Channel 100x50x5 mm, 3.5 M Length weighing approx 9.60Kg/Mtr
GI Angle 65X65X6 mm, 1.5 M Length weighing approx 5.8 Kg/Mtr for 1Pole (SP) Brackets
GI Angle 65X65X6 mm , 5 M Length weighing approx 5.8 Kg/Mtr for 2Pole (DP) Bracing -
Pole Double Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top Section ) weighing 1.4 kg per pair
Pole Single Clamp of G.I flat 50x6 mm suitable for GI SP 35 ST Pole
dia - 90 mm (Top section) weighing 0.7 kg each for SP Brackets
dia - 115 mm (Middle section ) weighing 0.84 kg each for DP Bracing & Crossing
GI Nuts (heavy) & Bolts (full thread) of following sizes
16 mm dia x 250mm ((5/8"x10") each weighing 0.50 kg
16 mm dia x 150mm ((5/8"x6") each weighing 0.348 kg
16 mm dia x 75mm ((5/8"x3") each weighing 0.23 kg
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
HT stay set with GI Rod of 19mm dia and 1.6 Mtr Length, guy insulator complete set
GI Pipe 2", 3 mtr length for Pole Earthing
G.I Stay wire , 7/10 SWG, 14Mtr per stay set (weighing 0.460 kg per mtr)
G. I. wire , 6 SWG for Pole earthing weighing 0.192 kg /mtr
11 kV Polymer Disc insulator B&S (70KN)
11kV Pin Polymer Insulator with GI Pin (24mm) with nuts and washers
H/W fittings for 11KV Polymer Disc Insulator (B&S) type 70KN tension type with DE Clamp (2 bolts)
ACSR Weasel Conductor
Tension Claim for ACSR Weasel
PG Claim for ACSR Weasel
11kV Danger plate
GI Barbed wire 12SWG for Anti Climbing device weighing 0.17kg/Mtr.
C. CABILING WORKS (LT bare to L T ABC replacement )
(C-1) Supply of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-70 Sq.mm on SP-11 Pole
GI Steel tubular pole SP-11
Pole Double Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Pole Single Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Cable ABC 1.1 kV XLPE with insulated messenger with one Streelight Cond. 3CX 70Sqmm (213A) + 1CX 50 Sqmm (Insulated Messenger/Neutral) + 1CX 16 Sqmm (Street light).
Cable Tie
Anchor clamp wedge type LT ABC as per NFC standard
Suspension Clamp ABC as per NFC standard
Eye Hook/Eye Bolt
Insulating Piercing Connector IPC EP95 for Streetlighting as per NFC Std.
Insulating Piercing Connector IPC P2X95 FOR DB CHARGING as per NFC Std.
Insulating Piercing Connector IPC P3X95 for ABC to ABC TEE connection as per NFC Std.
Cable end caps for ABC cables
ASA Distribution box for 140A, 1Ph. 10 Connectors with Spring Loaded Busbar System
Steel Strap for Installing DB size 20 mm X 1 m long
Buckles for steel Strap for DB Fixing
Insulated Waterproof bimetallic lug for Transformer Connections (Set contains 5 nos. Lugs as per Cable) as per NFC Std.
Insulated Crimping type Midspan Joint (Set contains 5 nos. Ferrules as per Cable) as per NFC Std.
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
LT stay set with GI Rod of 16mm dia and 1.6 Mtr Length,Bow,Anchor Plate, guy insulator etc complete set
G.I Stay wire , 7/12 SWG, 10Mtr per stay set (weighing 0.300 kg per mtr)
(C-2) Supply of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-50 Sq.mm on SP-11 Pole
GI Steel tubular pole SP-11
Pole Double Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Pole Single Clamp 90mm dia (Top Section) made of G.I flat 50x6 mm, suitable for SP 11 GI ST Poles
Cable ABC 1.1 kV XLPE with insulated messenger with one Streelight Cond. 3CX 50Sqmm (213A) + 1CX 25 Sqmm (Insulated Messenger/Neutral) + 1CX 16 Sqmm (Street light).
Cable Tie
Anchor clamp wedge type LT ABC as per NFC standard
Suspension Clamp ABC as per NFC standard
Eye Hook/Eye Bolt
Insulating Piercing Connector IPC EP95 for Streetlighting as per NFC Std.
Insulating Piercing Connector IPC P2X95 FOR DB CHARGING as per NFC Std.
Insulating Piercing Connector IPC P3X95 for ABC to ABC TEE connection as per NFC Std.
Cable end caps for ABC cables
ASA Distribution box for 140A, 1Ph. 10 Connectors with Spring Loaded Busbar System
Steel Strap for Installing DB size 20 mm X 1 m long
Buckles for steel Strap for DB Fixing
Insulated Waterproof bimetallic lug for Transformer Connections (Set contains 5 nos. Lugs as per Cable) as per NFC Std.
Insulated Crimping type Midspan Joint (Set contains 5 nos. Ferrules as per Cable) as per NFC Std.
GI Washers 3mm thick of 16mm (5/8") inner dia each weighing 0.011Kg, suitable for 16mm (5/8") thread bolt
LT stay set with GI Rod of 16mm dia and 1.6 Mtr Length,Bow,Anchor Plate, guy insulator etc complete set
G.I Stay wire , 7/12 SWG, 10Mtr per stay set (weighing 0.300 kg per mtr)
Description of Work / Item(s)
Amount
A. 11 KV INFRA FOR DOWNLINKING WITH NERPSIP SCHEME
(A-1) Erection, Installation, Commissioning & Testing of Materials 11 kV Line with MINK conductor (10 M GI STP SP-45 Pole)
Detail Survey
Tree cutting along the line including trimmimg, looping, branching etc as required
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, GI earth pipes etc.
Stringing of conductors
Erection of stay wires
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(A-2) Erection, Installation, Commissioning & Testing of Materials 11 kV Line with HARE conductor (12 M GI STP SP-66 Pole)
Detail Survey
Tree cutting along the line including trimmimg, looping, branching etc as required
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, GI earth pipes etc.
Stringing of conductors
Erection of stay Set
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(A-3) Erection, Installation, Commissioning & Testing of Materials 11 kV Line with Weasel conductor (9.5 M GI STP SP-35 Pole)
Detail Survey
Tree cutting along the line including trimmimg, looping, branching etc as required
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, GI earth pipes etc.
Stringing of conductors
Erection of stay wires
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
B. 11 KV RECONDUCTORING
(B-1) Erection, Installation, Commissioning & Testing of Materials for 11kV Line Reconductoring with MINK Conductor (60Sq mm) ( 10 M GI STP SP-45 Pole)
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, Clamp,GI earth pipes, anti climbine device etc.
Stringing of conductors alongwith all required accessories
Erection of stay Sets
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(B-2) Erection, Installation, Commissioning & Testing of Materials for 11kV Line Reconductoring with HARE Conductor ( 12 M GI STP SP-66 Pole)
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, Clamp,GI earth pipes, anti climbine device etc.
Stringing of conductors alongwith all required accessories
Erection of stay Sets
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(B-3) Erection, Installation, Commissioning & Testing of Materials for 11kV Line Reconductoring with WEASEL Conductor ( 9.5 M GI STP SP-35 Pole)
Erection of poles including excavation of earth; fitting of channels, angles, Hardware fittings, insulators, Clamp,GI earth pipes, anti climbine device etc.
Stringing of conductors alongwith all required accessories
Erection of stay Sets
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
C. CABILING WORKS
(C-1) Erection, Installation, Commissioning & Testing of of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-70 Sq.mm on SP-11 Pole
Erection of poles including excavation of earth; fitting of Insulators & Accessories, Hardware fittings, etc.
Stringing of Cables ABC & Installation of all required accessories
Installation of Eye Hook/Eye Bolt, Insulating Piercing Connectors for Street Light, DB Charging and ABC to ABC TEE Connection
Installation of Anchor & Suspension Clamp
Installation of ASA Distribution box and Accessories
Installation of Pole clamp
Installation of Insulated Waterproof bimetallic lug Insulated Crimping type Midspan Joint
Erection of stay Set
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
(C-2) Erection, Installation, Commissioning & Testing of Materials for Construction of 3 Ph, 5 Wire LT Line AB Cable-50 Sq.mm on SP-11 Pole
Erection of poles including excavation of earth; fitting of Insulators & Accessories, Hardware fittings, etc.
Stringing of Cables ABC & Installation of all required accessories
Installation of Eye Hook/Eye Bolt, Insulating Piercing Connectors for Street Light, DB Charging and ABC to ABC TEE Connection
Installation of Anchor & Suspension Clamp
Installation of ASA Distribution box and Accessories
Installation of Pole clamp
Installation of Insulated Waterproof bimetallic lug Insulated Crimping type Midspan Joint
Erection of stay Set
PCC 1:3:6 Grouting of Poles (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
PCC 1:3:6 Grouting of Stay (1.5ftx1.5ftx4 ft) per pole - 0.25 Cum)
Description of Work / Item(s)
Amount
Taxes Applicable on Supply and Erection, Installation & Commissioning of Materials
Total GST on Supply of Materials (BoQ1)
Total GST on Erection, Installation & Commissioning (BoQ2)
Description of Work / Item(s)
Amount
TOTAL SCHEDULE NO. 1
Ex-works supply of materials (BoQ1)
TOTAL SCHEDULE NO. 2
Erection, Installation & Commissioning (BoQ2)
TOTAL SCHEDULE NO. 3
Taxes (BoQ3)
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
NATIONAL POWER SYSTEMS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html