| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.2 LAccepted-AOC THEERTHAM NADUVILEMURI PADANILAM POST NOORANAD ALAPPUZHA DIST KERALA 690529 | ALAPPUZHA | KERALA | 690529 | L1 | Accepted-AOC Lowest quoted amount overall reasonable | |
| 2 | L2₹24.9 L+₹2.5 L (11.0%)Rejected-AOC H NO 831 1 HINDU NAGAR TILAKWADI BELGAUM 590006 | BELGAUM | BELGAUM | KARNATAKA | 590006 | L2 | Rejected-AOC 2nd lowest hence rejected | |
| 3 | L3₹29.5 L+₹7.1 L (31.6%)Rejected-AOC 3 358 PALLICKAL KRISHNALAYAM PAKALKURI PO VARKALA THIRUVANANTHAPURAM KERALA 695604 | VARKALA | THIRUVANANTHAPURAM | KERALA | 695604 | L3 | Rejected-AOC 3rd lowest hence rejected |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
21 Jan 2023, 6:00 pmClosed
Garrison Engineer Belgaum
Garrison Engineer Belgaum, Laxmi Tek, Camp, Belgaum
REPAIRS AND MAINTENANCE OF SUB STATIONS, LIGHTNING CONDUCTORS AND CERTAIN OTHER MISCELLANEOUS WORKS AT AREA NO 01 AND 02 UNDER GE BELGAUM
2022_MES_571033_1
8891/E8
Open Tender
Civil Works
Item Rate
240 days
Belgaum
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Belgaum
₹60,000
Yes
3 Mar 2023
24 Dec 2022
23 Jan 2023
24 Dec 2022
21 Jan 2023
7 Jan 2023
Amount
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth .and getting out in hard / dense soil for laying of cable / pipes etc including taking out old brick of any description and taken as credit complete all as specified and as directed. Note:- (i) Exsisting sand cushioning for cable shall not be removed.
Returning, filling in trenches with excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand complete all as specified and as directed. Note : Measurement of Consolidated sand only will be considered for payment .
Material and labour for well burnt old size sub Class ‘B’ bricks, laid flat, in trenches for cable protection complete all as specified and as directed.
Taking out HT un-serviceable / faulty cable of Cross sectional area 185 sq mm, 3 core from trench / pole / cable duct carefully including bricks, pipe and stacking properly for disposing off from site or for relaying in same place complete all as specified and as directed. Note : (i) Excavation and earth work shall be measured and paid separately. (ii) The rate quoted by the contractor for this item sahll include the cost of taking out brick protection/ tiles and GI Pipe etc as applicable. (iii) Old serviceable cable shall be stored properly for relaying and unserviceable HT cable of any description taken as credit .
All as per description of item No. 6.00 here in before but cable of cross sectional area 120 sqmm, 3 core
All as per description of item No. 6.00 here in before but cable of cross sectional area 95 sqmm, 3 core
Laying and testing of HT serviceable PVC / XLPE insulated 11000 Volts grade with aluminium conductor cable of cross sectional area 185 sq mm, 3 core in trench or fixed to wall /passing through pipe / pole complete all as specified and as directed. Note : (i) Old serviceable cable retrived under Item No. 6.00 here-in-before shall be reused in the work. (ii) Brick protection, concrete cable cover, sand cushioning shall be measured and paid separately.
All as per description of serial item No. 9.00 here in before but HT cable of cross sectional area 120 sqmm, 3 core.
Supply, lay and test HT XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 volts grade with stranded aluminium conductor of size 95 sqmm 3.0 core including lugs,thimbles and ferrules etc as per IS-7098 (Part-II), in trenches or fixed to wall /passing through pipe / pole complete all as specified and as directed . Note : (i) Excavation and earth work shall be measured and paid for separately. (ii) Concrete cover protectioin and sand cushioning shall be measured and paid for separately. (iii) GI Pipe for road crossingincluding clamps shall also be measured and paid separately. (iv) Make of HT cable :Gloster/Finolex/CCI ,Mumbai / Polycab
All as per description of item No. 11.00 here in before but HT XLPE cable of cross sectional area 120 sqmm, 3 core
All as per description of item No. 11.00 here in before but HT XLPE cable of cross sectional area 185 sqmm, 3 core
Material and labour for Straight through joint HT 11000 volts grade heat shrinkable of cable Cross sectional area 185 Sqmm, 3 core complete all as specified and directed. Note : (i) Make of HT cable joint: Raychem/Denson/ Birla-3 M (ii)Excavation and earthwork shall be measured and paid separately
All as per description of item No. 14.00 here in before but for cable of cross sectional area 120 sqmm, 3 core
All as per description of item No. 14.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
Material and labour for End termination joint (Out door type) heat shrinkable HT 11000 volts grade of cable Cross sectional area 120 Sqmm, 3 core complete all as specified and as directed. Note : (i) Make of HT end termination joint: Raychem/Denson/ Birla-3 M
All as per description of serial item No. 17.00 here in before but for cable of cross sectional area 185 sqmm, 3 core
Material and labour for End termination joint (Indoor type) heat shrinkable HT 11000 volts grade of cable Cross sectional area 185 Sqmm, 3 core complete all as specified and as directed . Note : (i) Make of HT end termination joint: Raychem/Denson/ Birla-3 M
All as per description of serial item No. 19.00 here in before but for cable of cross sectional area 120 sqmm, 3 core.
All as per description of serial item No. 19.00 here in before but for cable of cross sectional area 95 sqmm, 3 core
Supply and lay 100 mm bore Galvanized iron pipe , “Light grade”, including all fittings and fixed on pole/walls/in road etc for cable protection complete all as specified and as directed. Make : TATA/JINDAL/Prakash surya
Material and labour for Tracing out fault in 11KV underground cable of any size with the help of fault tracing machine and rectifying the same with joints as specified and directed to restore the supply complete all as specified. Note: (i). Joint kit shall be measured and paid separately. (ii) Earth work shall be measured and paid separately. However, width of trenches shall be allowed for payment as per authorized width given in SSR for each size of cable. (iii) All other necessary arrangements suitable for locating the faults deemed to be included in the unit rate quoted by the contractor for this item. (iv) T&P required for the entire job shall be provided by the contractor at his own cost and nothing extra shall be admissible on this account. (v) Cable required, if any shall be measured and paid for separately. (vi) Fault & location thereof shall be traced within 12 hours of intimation by the Engineer-in-Charge and shall be rectified within given time frame.
Supply and filling Transformer power oil meeting IEC 60296-2003-11, 3rd edition standard specification and ASTMD 1275B test requirements for corrosive sulpher of BDV not less than 65 KV for topping up the Power/distribution transformer HT 33 KV / 11 KV complete all as specified and directed. NOTE:-(i) Transformer oil shall be brought by the contractor in sealed standard packing in barrell of 210 ltrs capacity. (ii) Contractor shall produce the original purchase vouchers and test certificate from the manufacturer.
Material and labour for Filteration and dehydration of transformer oil by dehydration machine to achieve the die-electric strength / insulation value upto 65 KV/40KV (RMS) at standard gap of electrodes 2.5 mm for one minute in various capacity of transformers 33/11KV and 11/0.433KV including insulation testing of oil with the help of suitable equipments before and after dehydration including BDV Test complete all as specified and as directed.
Supply and fix in repairs PG clamp die cast aluminium of suitable size for fixing /clamping ACSR conductor connections for PT's CTs isolators complete all as specified and as directed.
Disconnecting, opening of Outdoor type Ring Main Unit 2 way ( one incoming and one outgoing) (Make : Schneider/ Megawin / ABB Ltd, Alstom/Crompton) of any description and any make of rating 11 KV 400/630/800 Amps capacity for servicing / overhauling, taking out and removing unserviceable / defective parts including cleaning & servicing, greasing, oiling of the parts etc and replacement of unserviceable parts with new one, reassembling the VCB after overhauling/ servicing and testing complete all as specified and as directed.
Note: (i) Replacement of unserviceable parts shall be measured and paid separately under relevent item of BOQ as supply only but fixing charges of the parts replaced /repaired is deemed to be included in this item . (ii) Servicing shall be got carried out by the authorised dealer of the VCB manufacturer and the service engineer will submit a service report and calibration certificate for each VCB. (iii) Any item not included in CA and required for successful operation of the panel will be provided by the contractor and the rate quoted by the contractor for this item shall deemed to be included the above provisions.
All as per description of serial item No. 27.00 here in before but 3 way RMU having 1 No Incoming and 2 Nos out going
All as per description of serial item No. 27.00 here in before but 4 way RMU having 2 Nos Incoming and 2 Nos out going
All as per description of serial item No. 27.00 here in before but 5 way RMU having 3 Nos Incoming and 2 Nos out going
Material and labour for Testing and Calibration of 11KV Ring Main Unit /SF6 circuit Breaker 2 way Make : Schneider/Crompton / Megawin / Denson / ABB Ltd /Alstom) Outdoor/indoor type alongwith control panel and control wiring, protection system and relay system (relay to tripping coil auxiliary switch male and female housing cut outs etc) , checking of quality of vacuum interrupter, insulation resistances, static contact resistance, Testing (IR value, Ratio test, Polarity test) and connection verification of 11 KV Current transformer (Set of three) by PRIMARY INJECTION KIT and Testing and calibration of relay (set of two Over current and one earth fault) by SECONDARY INJECTION KIT including all other functional tests of the VCB, C&R panel and CTs, PTs. complete all as specefied and as directed.
Note: (i) Servicing shall be got carried out by the authorised dealer of the RMU manufacturer and the service engineer will submit a service report and calibration certificate for each RMU. (ii) Any item not included in CA and required for successful testing and calibration of RMUwill be provided by the contractor and the rate quoted by the contractor for this item shall deemed to be included the above provisions.
All as per description of serial item No. 31.00 here in before but 3 way RMU having 1 No Incoming and 2 Nos out going
All as per description of serial item No. 31.00 here in before but 4 way RMU having 2 Nos Incoming and 2 Nos out going
All as per description of serial item No. 31.00 here in before but 5 way RMU having 3 Nos Incoming and 2 Nos out going
Material and labour for Repair to distribution transformer step down 11/0.433 KV indoor/outdoor type of capacity up to 250 KVA, by dismantling the transformer carefully, opening the top cover of transformer for inspection /repair, draining out the transformer oil from the housing complete, taking out the core and winding by disconnecting the internal connections, removing the carbon/sludge deposit in transformer housing core, replacement of unserviceable rubber bushes and washers, replacement of tap changer winding and thimbles, replacement of silica gel, replacement of top cover gasket set including pasting with pasting material, replacement of worn out nut and bolts, replacement of unserviceable LT & HT bushes, cutting the burnt out winding and re-winding the same with suitable size of super enamelled copper wire as per existing guage, insulating the winding connection by using fire proof sleeve and fire proof tape, varnishing the coil, keeping the coils in electric
oven chamber for 24 hours to remove the moisture, painting of complete transformer body from outside and inside, marking of MES/SM Number etc, replacement of conservator tank glass, re-installing the core and winding inside properly, making the all connection with suitable copper lugs, filling of new transformer oil, reinstalling the top cover after cleaning and painting of housing, conservator tank, explosion vent etc, Meggering the LT and HT side of the Transformer and testing complete all as specified and as directed. Note :- (i) Winding wire for making of coils, HT/LT bushes, new transformer oil will be measured & paid for seperately (ii) Contractor is required to submit test report for repaired transformer duly signed by Engineer-in-Charge before installation.
All as per description of serial item No. 35.00 here in before but capacity of transformer 11 / 0.433 KV, above 250 KVA upto 630 KVA
Supply only brass terminal rod with nut, bolt washer and bushing suitable for HT and LT side of the transformer of any make and capacity upto 250 KVA complete all as specified and as directed..
All as per description of serial item No. 37.00 here in before but capacity of transformer exceeding 250 KVA but not exceeding 400 KVA.
Supply only super enamelled copper conductor wire of suitable gauge and size as per requirement for rewinding of 11/0.433 KV distribution transformercomplete all as specified and as directed..
Material and labour forEarthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 and
the GI earthing strip to be protected by galvanlsed iron pipe 40 mm bore (medium grade) upto ground leveland there after with 40 mm dia GI pipe upto test point. Earthing shall be included with providing funnel with 20 mm bore galvanised iron pipe (light grade), wire mesh , charcoal or coke and common salt in alternate layer of 15 cm (compacted thickness) upto 90 cm all round earth plate further filled with 60 cm thick sand up to the ground level. Earthing shall also be include for providing concrete earth pit in PCC (1:3:6) type C -1 (with 20mm grade aggregate), 50 mm thick precast RCC (1:2:4) cover slab (re inforced with Excavation, returning filling and removal of surplus soil upto a distance not exceeding 50 mtr etc all as shown on electrical Plate No 3 of MES schedule Part I complete to obtain less than 2 Ohm earth recistance valueconnected to earthing test point all as specified or indicated including testing on completion all as specified and directed. Note :- Plate No 3 of SSR Part I is given for guide line of earth chamber.
Material and labour for Repair to LT Panel board indoor / outdoor type of any capacity having 1 No Incomer & out going MCCB's up to 6 Nos (Max) by carrying out the following works:- (i) Cleaning incomer switches, bus bar & out going switches etc thoroughly by using blower. (ii) Replacement of rusted bolts & nuts, screws, thimble etc as per existing. (iii) Replacement of Indicator lamps, Volt meter, Amps meter, VSS, ASS as per existing. (iv)Replacement of Incoming / out going switches as per existing make & model. (v) Replacement of control wiring with suitable size as per existing copper wire (vi) Making the locking arrangement functional including welding if required (vii) Replacement of MV danger board (viii) Making proper connections for out going / incoming cable by providing suitable thimble as required. Note:Only MCCB's, shall be measured and paid separatly as 'Supply only' against respective item of this Schedule..
Supply only following fixtures / fittings for replacement in LT Panel boards:- MCCB, 36 KA, 4 pole, 400A Note :Make of MCCB : Siemen/Indo Asian /Legrand
MCCB, 36 KA, 4 pole, 200A 50HZ AC supply current rating conforming to IEC-609472 & IS-139473
MCCB, 36 KA, 4 pole, 160A 50HZ AC supply current rating conforming to IEC-609472 & IS-139473
MCCB, 16 KA, 3 pole, 125A 50HZ AC supply current rating conforming to IEC-609472 & IS-139473
MCCB, 16 KA, 3 pole, 100A 50HZ AC supply current rating conforming to IEC-609472 & IS-139473
Taking out following defective cable XLPE/PVC sheathed 1100 volt grade heavy duty armoured with aluminium conductor of any Cross sectional area from trenches, from wall/poles/under floor etc, shifting serviceable cable for relaying or removing the unserviceable cable and taken as credit complete all as specified and as directed. Note : (i) Excavation and earth work shall be measured and paid for separately (ii) Unit rate of this item shall includes the removal of brick/tile as cable protection, GI pipe and cable joint etc. and nothing extra shall be admissible on this account. (iii) After taking out the cables from the trench, serviceability of cable shall be checked by the contractor in presence of the Engr-in-Charge and nothing extra shall be paid on this account.
Supply,lay and test XLPE insulated, armoured, heavy duty, 1100 Volts grade aluminium conductor cable of Cross sectional area 16 Sqmm, 4 core in trenches or fixed to wall / passing through pipe / pole and testing compete all as specified and as directed Note : (i) Excavation & earth work, Brick protection and sand cushining shall be measured and paid separately,(ii) Make of XLPE cable :Gloster/Poly cab /CCI/Finolex
Description all as per item no :48 here in before but cable of cross sectional area 25 sqmm 4 core
Description all as per item no :48 here in before but cable of cross sectional area 35 sqmm 3.50 core
Description all as per item no :48 here in before but cable of cross sectional area 50 sqmm 3.50 core
Description all as per item no :48 here in before but cable of cross sectional area 70 sqmm 3.50 core
Description all as per item no :48 here in before but cable of cross sectional area 95 sqmm 3.50 core
DHAIRYASIL RAMAKANT DESAI
M/s VJ ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .