Loading…
Loading…
Tender ID
Tender Value
₹12.3 Cr
EMD Value
₹22.3 L
Closing Date
12 Feb 2026, 3:00 pmClosed
Executive Engineer, AURANGABAD
EE
Executive Engineer, AURANGABAD, BCD , AURANGABAD
Superintending Engineer, BUILDING CIRCLE GAYA
SE
CONSTRUCTION OF BLOCK-CUM-CIRCLE OFFICE BUILDNG AT MADANPUR-BLOCK IN AURANGABAD, BIHAR
123394
10/BCD/AURANGABAD/2025-26
Open Tender
GENERAL
Aurangabad
• PAY OLINE ON EPROC WEBSITE
OR
(a) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1
Bid Security Amount in Rupees
Total Bid Security Amount in Rupees Rs. 2225600.00
• (i) Legal Status of Bidder 4.3(a)
(ii) Place of Registration.
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid 4.2(iv)
• Total value of civil engineering construction work, in Rupees, Performed in last five years. Minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work ,which must be at least equal to 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year
4.5(A) (a)
2020-21
2021-22
2022-23
2023-24
2024-25
• Amout in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost
4.5(A) (b)
• (c) Executed in any one year, the minimum quantities /amount of the following items of work (units shall be same as in Requirement column)
EARTH WORK 1200 CUM
BRICK WORK 540 CUM
RCC/PCC 1050 CUM
Tiles work (kota+ marble+ vitrified +granite) 2050 SQM
PHE Rs. 922000.00
ELECTRICAL Rs. 11128000
FURNITURE Rs.4969000.00
FIRE FIGHTING Rs. 1656000.00
• Electrical License The contractor or his identified sub-contractor should possess required valid electrical license for executing the building electrification works and should have executed similar electrical works for a minimum amount as indicated in Appendix in any one year 4.5A( d)
• (a) Amount of Existing commitments and ongoing works in Rupees Sec 2-1.4(A)
(b) Amount of Work for which Bid already submitted, in Rupees Sec 2-1.4(B)
• Numbers and Maximum age of Equipments with bidder
Type of Equipment Maxm. Age Nos Sec 2-1.5
Concrete Mixer with Integral weigh Batching facility 5 2 NOS
Vibrator (Plate & Niddle) 5 4 NOS
Water Tanker 5 1 NOS
Steel shuttering 5 3000 sft
• Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification 4.5(B) (b)
1 Site Engineer B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 1 No.
2 Site Supervisor Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 2 Nos.
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of creadit facilities (10% of estimated cost), certified by bankers (for work under this bid). 4.2(i)
• Proposed methodology and programme of construction Select from drop down list the proposed methodology and programme of construction, backed with equipment planning and deployment 4.3(l)
• Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
Affidavit Regarding statements made in the required attachments are true and correct. Sec-2, Affidavit
Undertaking Able to invest a minimum of cost upto 25% of contract value of work. During implementation of contract. Sec-2, Undertaking 25%
• Registration No.
IT.& ST Registration & clearance Certificate
• Labour License
Character Certificate
• NOC for Debar (If required)
GENERAL
PERCENTAGE
L1
1
13 documents required · 13 mandatory
₹10,000
Processing Fee: 5900
₹22.3 L
15-01-2026 03:00 pm AT OFFICE OF SE GAYA CIRCLE, BCD , GAYA
20 Jan 2026
20 Jan 2026
13 Feb 2026
20 Jan 2026
12 Feb 2026
20 Jan 2026
Bill OF Quantity
CONSTRUCTION OF BLOCK-CUM-CIRCLE OFFICE BUILDNG AT MADANPUR-BLOCK IN AURANGABAD, BIHAR
Estimated Cost : ₹ 0.00
Earnest Money : ₹ 0.00
Cost of B.O.Q. : ₹ 10,000.00
Date of Tender :
Sl. No. SOR Item of Work Unit Main Building PHE Septic Tank RWH Road Fire Fighting B Wall Landscape Site Development UGWT Boring Furniture Qty. Rate Amount
1 2.32 Clearing jungle including uprooting or rank vegetation, grass, brush wood, trees and scaplings of girth upto 30 cm measured at a height of 1 m above ground level and removal of rubbish upto a distance of 50 m outside the periphery of the area cleared. 100 sqm 1539 1539.00 697.40 10,733.00
2 2.8.1 Earth work in excavation in foundation trenches or drains(not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m . including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil
3 2.18 Close timbering over areas including strutting, shoring and packing, cavities (wherever required) etc. complete. (Measurement to be taken of the face area timbered):
All kinds of soil
4 2.27.1 Extra for every additional lift of 1.5 m or part there of in
All kinds of soil
5 2.28 Supplying and filling in plinth with local sand and under floors including watering ramming consolidating and dressing complete job.
6 2.25A Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead. Cum 816.00 816.00 411.70 335,947.00
7 2.34 Felling trees of the girth (measured at a height of 1 m above ground level) including cutting of trunks and branches removing the roots and stacking of serviceable material and disposal of unserviceable material.Beyond 30 cm girth up to and including 60 cm grith Each 5.00 5.00 215.20 1,076.00
8 11.72 Providing designation 100A one brick flat soling joints filled with local sand including cost of watering taxes royaltiy all complete as per building
9 11.79 Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
11.79.1 (a) 80 mm thick c.c. paver block of M-35 grade with approved colour design and pattern. m² 1457.000 1457.00 956.40 1,393,475.00
10 4.1.8 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level 1.4.8 (1 Cement :4 coarse sand :8 graded stone agregate 40 mm nominal size)
11 4.1.3 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level 1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
12 4.1.5 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level.1:2:4(1 Cement: 2 coarse sand:4 graded stone aggregate 20 mm nominal size)
13 4.1.6 Providing and laying in position cement concrete of specified grade exluding the cost of centring and shuttering-all work upto plinth level:1:3:6 (1 Cement; 3 coarse sand :6 graded stone aggregate 40 mm nominal size)
14 16.42 Cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 40 mm nominal size) in pavements, laid to required slope and camber in panels as required including consolidation finishing and tamping complete.
15 5.1.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level:1:1:2 (1 cement:1 coarse sand:2 graded stone aggregate 20mm nominal size) m³ 0.00 5961.90 0.00
16 5.1.2 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring,shuttering,finishing and reinforcement-All work puto plinth level:1:1:5:3(1 cement: 1.5 coarse sand:3 graded stone aggregate 20 mm nominal size) m³ 0.74 0.74 4688.30 3,469.00
17 5.33.1.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement:Concrete of M-25 grade with minimum cement content of 330 kg/cum
18 2.26 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth:consolidating each deposited layer by ramming and watering lead
19 5.33.2.1 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana /Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate /retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing andreinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement:Concrete of M-25 grade with minimum cement content of 330 kg/cum
All works above plinth level upto floor V level
20 6.1.14C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in
21 6.3C Extra for Brick work in superstructure above plinth level upto floor V level
22 5.22 Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.
23 5.9 Centring and shuttering including strutting,propping etc. and removal of form for.
A 5.9.1 Foundations, footings, bases of columns etc. for mass concrete.
B 5.9.6 Columns,Pillars, Piers, Abutments, Posts and Struts
C 5.9.5 Lintels, beams, plinth bams, griders, bressumers and cantilevers.
D 5.9.7 Stairs,(excluding landings) except spiral-staircaces.
E 5.9.3 Suspended floors, roofs, landings, balconies and access platform.
F 5.9.4 Shelves (Cost in situ)
G 15.9.16 Edges of slabs and breaks in floors and walis-
15.9.16.1 Under 20 cm wide
H 15.9.16 Centring and shuttering including strutting, propping etc. and removal of form for.
15.9.16.2 Edges of slabs and breaks in floors and walis- above 20 cms wide 137.00 137.00 570.70 78,186.00
I 5.9.19 Weather shade,Chajjas, corbels etc. including edges
J 5.9.2 Walls (any thickness) including attached pilasters. Butteresses, plinth and string courses etc.
24 6.1.14C+6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :Cement mortar 1:6 (1 cement: 6 coarse sand ) :Extra tor Brick work in superstructure above plinth level upto floor V cum
25 6.1.12C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :Cement mortar 1.:4 (1 cement: 4 coarse sand ):
26 7.23.1.4 Stone work (machine cut edge) for wall lining etc. (veneer work ) over 12 mm thick bed of cement lime mortar 1:1:6 (1 cement: 1 lime putty : 6 fine sand ) including pointing in white cement mortar 1:2(1 white cement: 2 stone dust) with an admixture of pigment matching the stone shade: (To be secured to the backing by means of cramps which shall be paid for seperately):Red sand stone- exposed face fine dressed with rough backing:40 mm thick
27 10.3 Providing and fixing in position collapsible steel shutters with vertical channes 20x10x2 mm and braced with flat iron diagonals 20x5 mm size with top and bottom rail of T-tron 40x40x6 mm with 40 mm dia steel pulleys complete with bots.nuts locking arrangement stoppers handies including applying a priming coat of approved steel primer.
28 6.1.12C+6.3C Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :Cement mortar 1.:4 (1 cement: 4 coarse sand ):Extra tor Brick work in superstructure above plinth level upto floor V cum
Plaster and Finishing Work
29 13.11.4 Cement plaster in course sand :12 mm cement plaster of mix:1:6(1 cement: 6 coarse sand)
30 13.11 12 mm cement plaster of mix :
31 13.11 12 mm cement plaster of mix :
32 13.17.1 Providing 12 mm thick plaster (1:3) with a floating coat of neat cement m² 10.30 10.30 203.6 2,097.00
33 13.24.2 6 mm cement plaster to ceiling of mix :1:4(1 cement: 4 coarse sand)
34 13.19 18 mm cement plaster in two coat under layer 12 mm thick cement plaster 1:5 (1 cement: 5 course sand) and a top layer 6mm thick cement plaster 1:3(1 cement: 3 coarse sand finiished rough with sponge
35 11.3.1 + 11.8 Cement concrete flooring 1:2:4(1 cement:2 coarse:sand:4 graded stone agregate) finished with a floating coat of neat cement including cement slurry, etc. but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate. Extra for making chequers of approved pattern on cement concrete floors, steps, landing, pavemerts etc. m² 83.50 83.50 325.40 27,171.00
36 11.41.2 Providing and laying vitrifed floor tiles in different sizes {thickness to be specified by the manufactruer) with water absorption's less than 0.08 % and conforming to IS : 15622 of approved make in all colours and shades, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand ) including grouting the joint with white cement and matching pigments etc., complete. 600x600
37 12.52 Grading roof for water proofing treatment withCement concrete 1:2:4(1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size)
37 16.90 Providing and laying tactile tile (for vision impaired persons as per standards) of size 300x300x9.8mm having water absorption less than 0.5% and conforming to IS: 15622, of approved make in all colours and shades in outdoor floors such as footpath, court yard, multi modals location etc., laid on 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes & patterns including grouting the joints with white cement mixed with matching pigments etc. complete as per direction of Engineer-in-Charge.
38 Derived Providing RCC (1:2:4) including making grooves laid in patreon of tiles 300x300
39 5.27 Providing and filling in position bitumen mix filler of Proportion 80 kg of hot bitumen, 1 kg, of c ement and 0.25 cubicmetre of coarse sand for expansion joints,
40 5.30 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections.
41 11.46.2 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
42 11.37 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturer) of 1 st quality conforming to IS : 13755 of NITCO , ORIENT , SOMANY , KAJARIA or equivalent make in colours such as white , Ivory , Grey , Fume , Red , Brown , laid on 20 mm thick cement motar 1:4 (1 cement: 4 Coarse sand) including grouting the joints with white cement and matching pigments etc, complete
43 11.36 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 (Thickness to be specified by the manufacture) of approved make in all colours, shades except burgundy , bottle green , black of any size as approved by Engineer-in-charge in skirting , risers of steps and dados over 12 mm thick bed of cement Motar 1:3(1 cement: 3 coarse sand ) and jointing with grey cement slurry @ 3.3 kg per sqm including pointing in white cement mixed with pigment of matching shade complete.
44 11.56.2 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
45 11.26.1 Kota stone slab flooring over 20 mm (average ) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete . Base with 1:1:1 (1 lime : 1 surkhi: 1 coarse sand ) / 1:4 (1 cement: 4 coarse sand)
46 11.27 Kota stone slabs 20 mm thick in risers of steps skirting. Dado & pillars laid on 12 mm (average (thick cement mortar 1:3 (1 cement: 3 coarse sand )
47 11.31 Extra for pre finished nosing in treads of steps of Kota stone / sand stone slab.
48 11.55.1 Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge :
Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
49 8.2. Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations, of required size,approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups,including rubbing, curing, moulding and polishing to edges to give high loss finish etc. complete at all levels.
Granite of any colour and shade
50 8.3 Providing edge moulding to 18 mm thick marble stone counters, vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.
8.3.2 Granite work
51 8.1.1.1 Marble work gang saw cut (polished and machine cut) of thickness 18mm for wall lining (veneer work) in c ement mortar 1:3 (1 cement :3 coarse sand) including pointing with white coment mortar 1:2(1 shite cement:2 marble dust) with an admixture of pigment to match the marble shade:(To be secured to the backing by means of cramps, which shall be paid for separately):White Marble-Raj Nagar Plain/Udaipur green marble/ Zebra block marble
Area of slab upto 0.50 sqm
52 11.19.1 Chequered terrazo tiles 22 mm thick with marble chips of sozes upto 6mm in floors jointed with neat cement slurry mixed with pigement to match the shade of the tiles, including rubbing and polshing complete on 20 nm thick bed of cement mortar 1:4 (1 cement:4 coarse sand)Light shade using white cement
53 13.12 15 mm cement plaster on rough side of single or half brick wall of mix.
54 13.18 15 mm cement plaster on rough side of single or half brick wall of mix.
55 16.69 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge). m² 9.00 9.00 7998.80 71,989.00
56 19.19 Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal\ size) as per standard design
19.15.2 With 20 mm diameter round bar Each 12.00 12.00 296.30 3,556.00
57 19.19 Providing and fixing in position precast R.C.C. manhole cover and frame of required shape and approved quality.
19.19.4.1 Circular shape 560 mm internal diameter Each 4.00 4.00 1393.20 5,573.00
58 19.32 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design.
19.32.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 2.00 2.00 33603.40 67,207.00
59 19.30 inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with mframe (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :
19.30.1 Inside dimensions 455x610 mm and 45 cm deep for single pipe line : Each 8 8.00 4266.80 34,134.00
60 13.80A.2 Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
61 13.46.1 Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm)
62 13.93 Painting with synthetic enamel paint of approved brand and manufacture to give an even shed.
13.93.1 Two or more coats on new work m² 142.50 6.12 148.62 84.50 12,558.00
63 13.77.2 Applying one coat of cement primer of approved brand and manufacture on wall surface:Distemper primer :Distempering with 1st quality washable distemper (ready made ) of approved manufacturer and of required shade and colour complete:Two or more coats on new work
64 13.78 Applying one coat of cement primer of approved brand and manufacture on wall surface :
65 13.79 Finishing walls with water proofing cement paint of approved brand and manufacture and of required shade to give an even shade
13.79.1 New work ( three or more caots) m² 175 175.00 81.2 14,210.00
66 13.81.3 Applying priming coat with ready mixed zinc chromate yellow primer of approved brand and manufacture on steel galvanized iron/steel works. m² 6.12 6.12 34.60 212.00
67 9.20.1 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1 st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
68 9.23 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of shutters (overall area of door shutter to be measured)
69 9.22 Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to I.S. 2202 (part I).
9.22.1 On one side only
70 10.12.1 rolled steel sections, joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6(1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with woodenplugs and screws or raw) plugs and screws or with fixing dips or with bolts and nuts as required, including providing and fixing of glass panes with glazing dips and special metal-sash putty pf approved make complete including applying a priming coat of approved steel primer; excluding the cost of metal beading and other fitting except necessary hinges or pivots as required:Doors:Extra for providing and fixing steel beading of approved shape and section with screws instread of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.
71 10.12.1 + 10.13B rolled steel sections, joints mitered and welded with 15x3 mm lugs 10 cm long with steel lugs embedded in cement concrete blocks 15x10x10 cm of 1:3:6(1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) or with woodenplugs and screws or raw) plugs and screws or with fixing dips or with bolts and nuts as required, including providing and fixing of glass panes with glazing dips and special metal-sash putty pf approved make complete including applying a priming coat of approved steel primer; excluding the cost of metal beading and other fitting except necessary hinges or pivots as required:Doors:Extra for providing and fixing steel beading of approved shape and section with screws instread of glaxing clips and met. Sash putty in steel doors, windows, Ventilators and comosite units.
72 10.15.2 Providing and fixing pressed steel door confirming IS code 4351 manufactured from commerical mild steel sheet of 1.25 mm thickness including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50 x 25 mm or base ties of 1.25mm pressed mild steel welded or rigidly fixed together by mechnical means, adjustable lugs with split end tail to each jamb including steel butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
73 22.8.1 Providing and laying integral cement based water proofing treatment including prepatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water froofing compound conforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test, All above operations to be done in order and as directed and specifed by the Engineer-in-Charge:With average thickness of 120 mm and minimum thickness at khurras point to be 65 .. m² 28.06 28.06 850.70 23,871.00
74 23.1 Trenching in ordinary soil upto a depth of 60 cm including removal and stacking of serviceable materials and then disposing of by spreading and neatly levelling within a lead of 50 m and making up the trenched area to proper levels by filling with earth or earth mixed with sludge of / and manure before and after flooring trench with water (excluding cost of imported earth, sludge or manure) cum 924 924.00 44.70 41,303.00
75 23.2 Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment) cum 282.00 282.00 143.50 40,467.00
76 23.4 Supplying and stacking of good earth at site including royalty but excluding carriage (earth measured in stacks will be reduced by 20 % for payment)
23.4.3 Screened through sieve of I.S. designation 4.75 mm cum 61 61.00 315.80 19,264.00
77 23.9 Mixing earth and sludge or manure in proportion specified or directed. cum 343.00 343.00 20.90 7,169.00
78 23.8 Spreading of sludge, dump manutre or/and good earth in required thickness (Cost of sludge, dump manure or/and good earth to be paid separately) cum 343 343.00 30.10 10,324.00
79 23.12 Uprooting rank vegetation and weeds by digging the area to a depth of 60 cm removing all weeds and other growth with roots by forking repeatedly, breaking clods, rought dressing, flooding with water, uprooting fresh growths after 10 to 15 days and then fine dressing for planting new grass, including disposal of all rubbish with all leads and lifts. 100 sqm 1539 1539.00 3418.20 52,606.00
80 23.10 Grassing with 'Doob' grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free form weeds and fit for moving including supplying good earth if needed.
23.10.3 In rows 5 cm apart in either direction. 100 sqm 1539 1539.00 1027.40 15,812.00
81 23.14 Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20 % 1 part of stacked volume of manure after reduction by 8 % ) flooding with water, dressing including removal of rubbish and surplus earth, if any with all leads and lifts (cost of manure sludge or extra good earth if needed to be paid for separately)
23.14.2 Holes 60 cm dia. And 60 cm deep. each 50 50.00 69.30 3,465.00
82 23.13 Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8 :1 (8 parts of stacked volume of earth after reduction by 8% ) flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and levelling as directed, within a lead of 50 m lift upto 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) cum 90 90.00 126.90 11,421.00
Plantation of trees & Shrubs/ creeps.
83 7.7 DSR-20 Providing and stacking of Bauhinia blakeana (Kachnar) of height 120-150 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. each 10 10.00 80.00 800.00
84 7.24 DSR-20 (Horticulture & Landscape) Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v each 10 10.00 60.00 600.00
85 7.16 DSR-20 (Horticulture & Landscape) Providing and stacking of Cassia fistula (Amaltash) of height 120-135 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge. each 5 5.00 65.00 325.00
Shrubs / Creeps
86 8.10 DSR-20 (Horticulture & Landscape) Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge. each 20 20.00 100.00 2,000.00
87 8.33 DSR-20 (Horticulture & Landscape) Providing and stacking of Hamelia patens of height 90-105 cm. bushy in big size HDPE bags as per direction of the officer-in-charge. each 20 20.00 100.00 2,000.00
88 8.48 DSR-20 (Horticulture & Landscape) Providing and stacking of Mussaenda erythrophylla (Rosea) of height 60- 75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge. each 10 10.00 110.00 1,100.00
89 26.88 Providing and fixing factory made single extruded WPC {Wood Polymer Composite) solid decorative type flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers {wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/mm', modulus of elasticity 850 N/mm' and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk 5.5 screws, all as per direction of Engineer-In- Charge. {Note: stainless steel butt hinges and necessary 5.5 screws shall be paid separately)
90 26.86 Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm, modulus of elasticity 900 N/mm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (M.S hold fast/lugs or SS dash fasteners shall be paid for Separately).
91 9.161 Providing and fixing fire resistant door frame of section 50 x 60 mm on horizontal side & 35 x 60 mm on vertical sides having built in rebate made out of 1.6 mm thick GI sheet ( Zinc coating not less than 120gm/m²) suitable for mounting 120 min Fire Rated Glazed Door Shutters. The frame shall be filled with Mineral wool Insulation having density min 96Kg/m³ . The frame will have a provision of G.I. Anchor fastners 14 nos ( 5 each on vertical style & 4 on horizontal style of size M10 x 80 ) suitable for fixing in the opening along with Factory made Template for SS Ball Bearing Hinges of Size 100x89x3mm for fixing of fire rated glazed shutter . The frame shall be finished with a approved fire resistant primer or Powder coating of not less than 30 micron in desired shade as per the directions of Engineer - incharge . (Cost of SS ball bearing hinges is excluded).
92 9.162 Providing and fixing 60 mm thick glazed fire resistant door shutters of 120 min Fire Rating confirming to IS:3614 (Part II) or EN1634-1:1999, tested and certified as per laboratory approved by Engineer-in-charge, with suitable mounting on door frame, consisting of vertical styles, top rail & side rail 60 mm x 60 mm wide and bottom rail of 110 mm x 60 mm made out of 1.6mm thick G.I. sheet (zinc coating not less than 120gm/m²) duly filled mineral wool insulation having density min 96 kg/m³ and fixing with necessary stainless steel ball bearing hinges of size 100x89x3mm of approved make, including applying a coat of approved fire resistant primer or powder coating not less than 30 micron etc all complete as per direction of Engineer-in-charge (panelling to be paid for seperately).
93 9.164 Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions etc., with G.I. beading made out of 1.6 mm thick G.I. sheet (zinc coating not less than 120 gm/m²) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at distance 75 mm from the edges and 150 mm c/c , including applying a coat of approved fire resistant primer/powder coating of not less than 30 micron on G.I. beading, & special ceramic tape of 5 x 20 mm size etc complete in all respect as per direction of Engineer-in- charge. The glass shall be clear, toughened, nterlayered, non-wired fire resistant having 11 mm thickness of approved brand with 120 minutes of fire resistance both integrity & radiation control (EW120) and minimum 15 min of insulation (EI15) and having a sound reduction of ?37dB and LT of 86% Glass shall be compliant to class 2(B)2 category of Impact Resistance as per EN 12600. The glass shold be manufactured in UL & TUV audited Facility and including UL-EU Certification.The maximum glazing size cannot be more than 1100 mm x 2200 mm (w x h) or 2.42 sq mts in total area. The test report for the complete system (Glazed Door or Partition) will be considered valid only if it contains the stamp and signature of the authorized signatory from the glass manufacturer. (Actual glass size is to be measured at site for payments).
94 9.48. Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
9.48.1 Fixed to steel windows by welding Kg 5573.34 2889.40 8462.74 144.50 1,222,866.00
9.48.2 Fixed to openings/ wooden frames with rawl plugs screws etc Kg 16.20 16.20 161.10 2,610.00
95 13.82.1 Painting with ready mixed paint of approved brand and manufacture in all shades to give an even shade:New steel work (two or more coats)
96 21.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / aneling,C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
a 21.1.1 For fixed portion
21.1.1.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)
b 21.1.2 For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
21.1.2.2 Powder coated aluminium (minimum thickness of powder coating 50 micron)
97 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
21.3.2 With float glass panes of 5.50 mm thickness(weight not less than 12.50 kg/sqm)
98 9.51.1 Providing and fixing fly proof galvanized M.S. wire gauge to windows and clerestory windows using wire gauge with average width of aperture 1.4 mm in both directions with wire of dia 0.63 mm all complete: mm:With second class teak wood beading 62x19 mm
99 9.97 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ),
100 9.96 Providing and fixing aluminium sliding door bolts, ISI marked
101 9.100 Providing and fixing aluminium handles, ISI marked
102 9.101 Providing and fixing aluminium hanging floor door stopper, ISI marked,
9.101.2 Twin rubber stopper each 180.00 180.00 60.80 10,944.00
103 9.83 Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
104 10.5 Providing and fixing 1 mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3mm MS gusset plates at the junction and corners.all necessary fittings completejncluding applying a priming coat of approved steel primer.
10.5.1 Using M.S. angle 40x40x6 mm for diagonal braces
105 10.36 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, ( for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.).
106 10.18 Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.Providing and fixing circular/hexagonal cast iron or M.S sheet box for ceiling fan clamp 140 mm internal dia, 73 mm height, 5 mm thick rim bottom and top lids, 1.5 mm thick M.S sheet with its top surface hacked for proper bonding top lid shall be screwed into the cast iron box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamps shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
107 12.39 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement:2 coarse sand:4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 mx1 mx400 micron, finished 12 mm cement plaster 1:3 (1 cement:3 coarse sand) and a coat of neat cement rounding the edges and making and finishing the outlet complete
108 4.17 Providing plinth protection 750 mm wide consisting of 12 mm thick cement plaster 1;6 with neat cement punning over 75 mm thick P.C.C. (1:3 :6) over brick flat soling over 75 mm thick local sand filling all complete
109 22.3 Providing and laying water proofin treatment to vertical and horizontal surfaces of depressed portions of W.C. kitchen and the like consisting of: (i) 1st course of applying cement slurry @ 4.4 kg/sqm mixed with waterproofing compound conforming tc IS 2645 in recommended proportions. (ii) 2nd course of 20 mm cement plaster 1:3 (1 cement:3 coarse sand)mixed with water proofing compound in recommended proportion,(iii) 3rd course of applying blown or/residual bitumen aplied hot at 1.7 kg. per sqm of area, (iv) 4th course of 400 micron thick PVC sheet.(Overlaps at joints of PVC shet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqni).
110 22.8 Providing and laying integral cement based water proofing treatment including prepatation of surface as required for treatment of roofs, balconies , terraces etc, consisting of following operations. (a) Applying and grouting a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with proprietary water -proofing compound cleaning the surface before treatment, (b) Laying cement concrete using broken bricks / brick bats 25 mm to 100 mm size with 50 % of cement mortar 1:5 (1 cement: 5 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 over 20 mm thick layer of cement mortar of mix 1:5 (1 cement: 5 coarse sand ) admixed with roprietary water froofing compound conforming to IS 2545 to reuired slope and treating similary the adjoining walls upto 300 mm height including rounding of junctions, or walls ad slabs. (c) After two days of proper curing applying a secoung coat of cement slurry admixed with proprietary water proofing compound conforming to IS : 2645. (d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement: 4 coarse sand ) admixed with proprietary water proofing compound conforming to IS : 2645 and finally finishing the surface with trowel with neat cement slurry and making of 300 x 300 mm square. (e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test, All above operations to be done in order and as directed and specifed by the Engineer-in-Charge.
22.8.1 With average thickness of 120 mm and minimum thickness at khurras point to be 65 .. m² 820.24 820.24 850.70 697,778.00
111 6.47A Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm. Clear depth and 250mm apron including cost of E/W. involved with 75mm cement concrete (1:4:8) over one brick designation 100-A flat soling in proper grade and slope at the base.the drain duly.plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l
112 18.33.1 Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve,with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10(1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominalsize) and inside plastering with cement mortar 1:3 (1 cement : 3coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design :
113 With common burnt clay F.P.S.(non modular) bricks of class designation 100A Each 25.00 25.00 7210.60 180,265.00
114 26A.1 Providing and supplying aluminium extruded tubular and other aluminium sections as per the rchitectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS74,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. ( The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).
115 26A.2 Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:
116 2.37.3 Along the external wall below concrete or masonary apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc.
2.37.3.1 With Chlorpyriphos/ Lindane E.C. 20% with 1% Concentration.
117 13.116 Forming groove of uniform size from 12 x 12 mm and upto 25 x 15 mm in plastered surface as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repairs to the edges of plaster panel and finishing the groove complete as per specifications and direction of the Engineer-in-charge.
118 5.45 Providing and fixing of expansion joint system related with wall joint (internal/external) location as per drawings and direction of Engineer-In- Charge. The joints shall be of extruded aluminum base members, self aligning / centering arrangement and support plates as per ASTM B221- 02. The material shall be such that it provides an Expansion Joints System suitable for vertical wall to wall/ wall to corner application, both new and existing construction in office Buildings & complexes with no slipping down tendency amongst the components of the Joint System The Joint System shall utilize light weight aluminum profiles exhibiting minimal exposed aluminum surfaces mechanically snap locking the multicellular to facilitate movement. (Material shall confirm to ASTM 6063).
5.45.2 Wall Joint of 150 mm gap.
120 A/R Signage
e Ceiling Suspended Nos. 20.00 20.00 3640.00 72,800.00
121 3.20 Case I RCD-25 Compacting original ground Compacting original ground supporting subgrade (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction) 0.00
122 3.18 RCD-25 Construction of subgrade and Earthen Shoulder (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2) 0.00
123 4.01 A RCD -25 Granular Sub-Base with Graded Material ( Table:- 400- 1) Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.) 0.00
Rate per cum for grading-II Material m³ 353.00 353.00 1255.30 443,121.00
124 Carriage Of Materials
WATER SUPPLY WORKS
125 18.8 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge.
Concealed work including cutting chases and making good the walls etc. 0.00
18.8.1 15mm nominal outer dia pipes Metre 120.00 120.00 278.20 33,384.00
18.8.2 20mm nominal outer dia pipes Metre 130.00 130.00 350.80 45,604.00
18.8.3 25mm nominal outer dia pipes Metre 60.00 60.00 463.10 27,786.00
18.8.4 32mm nominal outer dia pipes Metre 143.00 143.00 549.80 78,621.00
126 18.9 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching ,refilling & testing of joints complete as per direction of Engineer
18.9.1 15 mm nominal outer dia Pipes Metre 105.00 105.00 151.40 15,897.00
18.9.2 20 mm nominal outer dia Pipes Metre 120.00 120.00 205.30 24,636.00
18.9.3 25 mm nominal outer dia Pipes Metre 45.00 45.00 294.70 13,262.00
18.9.4 32 mm nominal outer dia Pipes Metre 135.00 135.00 359.10 48,479.00
125 18.48 Providing and placing on terrace (at all floor levels) polyethylene water storage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. liter 4000.00 4000.00 9.70 38,800.00
Exposed on walls 0.00
126 18.11 Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti corrosive bitumastic paint, cutting chases and making good the wall :
18.11.1 15mm dia nominal bore Metre 180.00 180.00 318.90 57,402.00
18.11.2 20mm dia nominal bore Metre 60.00 60.00 374.00 22,440.00
127 18.16 Providing and fixing brass stop cock of approved quality (screwed end).
18.16.1 15mm nominal bore Each 6.00 6.00 303.80 1,823.00
18.16.2 20mm nominal bore Each 7.00 7.00 328.00 2,296.00
128 18.17 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end). 0.00
18.17.2 32mm nominal bore Each 6.00 6.00 589.90 3,539.00
18.17.3 40mm nominal bore Each 2.00 2.00 707.30 1,415.00
18.17.4 50mm nominal bore Each 5.00 5.00 878.20 4,391.00
129 18.19 Providing and fixing gun metal non-return valve of approved quality (screwed end) 0.00
18.19.4.2 50mm nominal bore 0.00
Vertical Each 1.00 1.00 1320.80 1,321.00
130 18.21 Providing and fixing P V C connection pipe with brass unions.
18.21.2.1 45 cm length
15 mm nominal bore Each 87.00 87.00 85.20 7,412.00
131 18.22 Providing and fixing C.P. brass shower rose 15 or 20 mm inlet. 0.00
132 18.38 Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :
18.38.1 15 mm diameter pipe Metre 120.00 120.00 11.90 1,428.00
18.38.2 20 mm diamatre pipe Metre 130.00 130.00 13.90 1,807.00
18.38.3 25 mm diametre pipe Metre 60.00 60.00 18.40 1,104.00
18.38.4 32 mm diametre pipe Metre 143.00 143.00 21.60 3,089.00
18.38.5 40 mm diamatre pipe Metre 20.00 20.00 25.70 514.00
18.38.6 50 mm diamatre pipe Metre 220.00 220.00 30.20 6,644.00
133 18.46 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc.complete (new work) 0.00
18.46.1 15 mm nominal bore Each 6.00 6.00 158.80 953.00
18.46.5 40 mm nominal bore Each 2.00 2.00 419.70 839.00
134 18.49 Providing and fixing C.P. brass,bib cock of approved quality conforming to IS : 8931 Each 30.00 30.00 434.20 13,026.00
135 18.51 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS stamdards and weighing notless than 690 gms. 0.00
18.51.1 15 mm nominal bore Each 1.00 1.00 708.40 708.00
136 18.52 Providing and fixing C.P brass stop cock (concealed) of standard design and of approved mark conforming to IS:8931
18.52.1 15mm nominal bore Each 3.00 3.00 594.80 1,784.00
137 18.53 Providing and fixing C.P brass angle valve for basin mixer and gyser points of approved quality conforming to IS: 8931
138 18.65 Providing and fixing PTMT Soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. Each 17.00 17.00 96.80 1,646.00
139 18.76 Cutting holes up to 30 x 30 cm in walls including making good the same:
18.76.1 With common burnt clay F.P.S. (non modular) bricks Each 16.00 16.00 198.50 3,176.00
140 18.77 Cutting holes up to 15 x 15 cm in R.C.C. floors and roofs for passing drain pipe etc. and repairing the hole after insertion of drain pipe etc. with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) including finishing complete so as to make it leak proof. Each 17.00 17.00 217.10 3,691.00
141 18.79 Making holes up to 20 x 20 cm and embedding pipes upto 150 mm in diametre in masonary and filling with cement concrete 1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size ) including dispopsal of malba. Each 26.00 26.00 115.70 3,008.00
SANITARY INSTALLATION 0.00
142 17.7 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :
17.7.2 White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap Each 32.00 32.00 2369.90 75,837.00
143 17.8 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings Each 14.00 14.00 1500.00 21,000.00
144 17.28 Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete.
145 17.28.2.2 Flexible pipe 0.00
146 17.31 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. Each 17.00 17.00 1068.50 18,165.00
147 17.33 Providing and fixing 600x120x5 mm glass shelf with edges round off,supported on anodised aluminium angle frame with C.P. brass brackets and guard rail complete fixed with 40 mm long screws, rawl plugs etc., complete. Each 17.00 17.00 713.30 12,126.00
148 17.73 Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 0.00
17.73.2 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms Each 17.00 17.00 424.00 7,208.00
149 17.35 Providing and fixing soil, waste and vent pipes
Centrifugally cast (spun) iron socket & spigot (S&S) pipe as per IS: 3989 Metre 485.00 485.00 1022.90 496,107.00
150 17.37 Providing and fixing M.S. holder-bat clamps of approved design to Sand Cast iron/cast iron (spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),including cost of cutting holes and making good the walls etc. : 0.00
151 17.38 Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick bolts and nutts complete:100 mm:
Sand cast iron S&S as per IS - 3989 Each 41.00 41.00 550.80 22,583.00
152 17.39 Providing and fixing plain bend of required degree
Sand cast iron S&S as per IS - 3989 Each 57.00 57.00 346.10 19,728.00
153 17.42 Providing and fixing double equal junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete
Sand cast iron S&S as per IS - 3989 Each 5.00 5.00 720.00 3,600.00
154 17.42 Providing and fixing single equal plain junction of required degree with access door, insertion rubber washer 3 mm thick, bolts & nuts complete.
Sand cast iron S&S as per IS - 3989 Each 27.00 27.00 573.50 15,485.00
155 17.56 Providing and fixing terminal guard
Sand cast iron S&S as per IS - 3989 Each 25.00 25.00 399.60 9,990.00
156 17.58 Providing lead caulked joints to sand cast iron/ centrifugally cast (spun) iron pipes and fittings of diameter
157 17.60 Providing and fixing trap of self cleaning design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors.
17.60.1.3 Hubless centrifugally cast (spun) iron epoxy coated inside & outside as per IS:15905 Each 34.00 34.00 760.80 25,867.00
158 17.65 Painting sand cast iron/ centrifugally cast (spun) iron soil, waste vent pipes and fittings with two coats of synthetic enamel paint of any colour such as chocolate grey, or buff etc. over a coat of primer (of approved quality) for new work : 0.00
159 12.78 Providing and fixing on wall face unplasticised PVC (working pressure 4 kg per sqcm) rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
160 12.79 Providing and fixing on wall face unplasticised PVC moulded fittings / accessories for unplasticised-PVC rain water pipes conforming to IS:4985 including jointing with seal ring conforming to IS:5382 leaving 10mm gap for thermal expansion.
12.79.2.2 Single pushfit Coupler:
12.79.6.2 Shoe plain 0.00
161 12.80 Providing and fixing unplasticised-PVC pipe clip of approved design to unplasticised PVC rain water pipe by means of 50x50x50mm hard wood plugs, screwed with M.S screws or required length including cutting brick work and fixing on cement mortar (1:4) 1 cement:4 coarse sand and making good the wall etc. complete.
162 12.81 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diametre and weighing not less than 440 grams. Each 19.00 19.00 47.90 910.00
163 17.1 Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required : 0.00
17.1.1 White Vitreous china Orissa Pattern W.C pan of size 580x440mm with integral type foot rests. Each 10.00 10.00 4470.90 44,709.00
164 17.2 Providing and fixing white vitreous china pedastal type water closet (European type W.C pan) with seat and lid, 10 litre low level white P.V.C flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS: 7231, with all fittings and fixtures complete including cutting and making good the walls and floors wherever required. 0.00
17.2.1 W.C pan with ISI marked white solid plastic seat and lid. Each 17.00 17.00 4230.00 71,910.00
165 17.4 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430 x 260 x 350 mm and 340 x 410 x 265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions G.I. clamps, complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:
17.4.1 One urinal basin with 5 litre white P.V.C. automatic flushing cistern. Each 2.00 2.00 3723.20 7,446.00
17.4.3 Range of three urinal basin with 10 litre white P.V.C. automatic flushing cistern. Each 9.00 9.00 7929.00 71,361.00
166 17.6 Providing and fixing one piece construction white vitreous china squatting plate with an integral longitudinal flushing pipe, white P.V.C.automatic flushing cistern, with fittings, standard size G.I. / PVCflush pipe for back and front flush with standard spreader pipes with fittings, G.I clamps and C.P. brass coupling complete, including painting of fittings and cutting and making good the walls and floors etc. wherever required : 0.00
17.6.2 Range of two squatting plates with 5 litre white P.V.C. automatic flushing cistern. Each 3.00 3.00 7753.00 23,259.00
167 8.1 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone finished smooth.aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and 0.00
8.10.1 White Agaria Marble Stone sqm 5.63 5.63 3061.20 17,235.00
168 17.71 Providing and fixing PTMT liquid soap container 109 mm wide, 125mm high and 112mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105gms. Each 17.00 17.00 146.30 2,487.00
169 17.72 Providing and fixing PTMT towel ring trapezoidal shape 215 mm long, 200mm wide with a minimum distances of 37mm fromwall face with concealed fittings arrangement of approved quality, and colour, weighing not less than 88 gms. Each 17.00 17.00 204.70 3,480.00
170 17.61 Cutting chases in brick masonry walls for following diameter sand cast iron / centrifugally cast (spun) iron pipes and making good the same with cement concrete 1:3:6 ( 1 cement: 3 coarse sand : 6 graded stonea agregate 12.5mm nominal size) including necessry plaster and pointing in cement mortar 1:4 ( 1 cement: 4 coarse sand):
SEWARAGE & DRAINAGE
171 19.1 Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete : 0.00
172 19.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes inlcuding bed concrete as per standard design.
19.2.2 150mm diameter S.W. pipe Metre 10.00 10.00 494.40 4,944.00
173 19.4 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design : 0.00
19.4.3.1 180 x 150mm size P type
With Common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Each 9.00 9.00 1994.10 17,947.00
174 24.1 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level.
24.1.2.1 Rocky strata including Boulders:- 300 mm dia m 0.00 1118.60 0.00
175 24.3.2 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer -in-charge.
150 mm nominal size dia m 48.00 48.00 660.10 31,685.00
176 24.4 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths,as per direction of Engineer-in-charge.
24.4.1 100 mm nominal size dia m 0.00 573.10 0.00
177 24.5 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. m³ 1.21 1.21 1188.90 1,436.00
178 24.6 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. m³ 1.21 1.21 1195.60 1,444.00
179 24.7 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. m³ 1.21 1.21 1195.60 1,444.00
180 24.8 Gravel packing in tubewell construction in accordance with IS: 4097,including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge. m³ 1.59 1.59 1343.20 2,136.00
181 24.13.2 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of:
182 24.14.2 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.
183 24.15.2 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I).
184 24.12 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully develo ped, measuring yield of well by "V" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. Hours 8.00 8.00 916.80 7,334.00
185 A/R Supplying 2 HP submerssiable Motor with complete sets
(Rates Approved by S.E.,B.C.D Gaya Circle on dated 07/09/2016) Set 1.00 1.00 26000.00 26,000.00
186 18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement ,trenching,refilling & testing of joints complete as per direction of Engineer in Charge.
18.7.3 25 mm nominal outer dia Pipes m 90.00 90.00 317.30 28,557.00
Piping & Valves
187 7.0 Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
188 2.10 Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed , within a lead of 50 m
2.10.1.2 Pipes, cables etc. exceeding 80 mm dia . But not exceeding 300mm dia. Rm 250 250.00 391.70 97,925.00
189 14 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubbergasket, GI bolts, nuts, washers etc.as required :
190 11 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
II Internal Hydrant System
191 10 Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
10.1 Single headed Gunmetal set 3 3.00 7245.00 21,735.00
10.2 Single headed Stainless Steel set 7 7.00 5722.00 40,054.00
192 17 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
193 16.2 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304) set 3 3.00 4445.00 13,335.00
194 A/R Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, stove enamelled fire red finish with 'FIRE HYDRANT' written in front. Approximate size 2100x900mm. Each 3 3.00 9843.00 29,529.00
195 A/R Providing and placing in proper position Stainless Steel 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS:903). Each 3 3.00 1800.00 5,400.00
196 A/R Providing and fixing brass/bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 20 kg/cm2. 25mm dia Each 3 3.00 1355.00 4,065.00
197 A/R Supply, installation, testing & commissioning of 25mm dia air release valves of approved make on the top of each 150mm dia basement sprinkler ring main as per standard fire practice Each 2 2.00 1111.00 2,222.00
198 A/R Providing and fixing pressure gauges with isolation cocks and chrome plated copper pipes as hydrant station to read pressure from 0-25 kg/cm2 complete and of dial dia 150 mm. Each 2 2.00 1386.00 2,772.00
199 19.2 Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe Each 1 1.00 13636.00 13,636.00
III External Hydrant System
200 16.2 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304) set 14 14.00 4445.00 62,230.00
201 A/R Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, stove enamelled fire red finish with 'FIRE HYDRANT' written in front. Approximate size 2100x900mm. Each 7 7.00 9843.00 68,901.00
202 18.1 Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipecoupling as required : Each 7 7.00 2393.00 16,751.00
IV Fire Pumps & Accessories
203 1.0 (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
1.5 Main fire Pump
Type : Split casting
Speed (rpm) : 2965
204 3.0 a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) SuitableHP squirell cage induction motor TEFC type suitablefor operation on 415 volts, 3 phase 50 Hz AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Type : Split casting
Speed (rpm) : 2965
Capacity : 180 lpm
205 4 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
206 22 Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required Nos. 2 2.00 1442.00 2,884.00
Panel for fire pumps
207 A/R Providing, fixing, testing and commissiong of motor control centres fabricated from 16 gauges MS sheet with powder coated finish. The control panels should be comparable with H.P. of the motor as specified.
Panel for fire pumps
208 A/R Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder Coated finish. The control panels should be compatible with H.P. of the motor as under and as per spcifications with automatic star delta starters. (One separate panel to be located in the plant room).
a) One incoming main isolation MCCB TP of Min. 250 Amps. rating.
b) Fully taped aluminium bus bar of required capacity in a separate bus bar chamber.
c) Isolation MCCB for each unit of required rating and with fully automatic starter as per requirement with push button and ON/OFF indicating lights for each unit, for following requirements:
i) One main fire pump of 50 HP.
ii) One jockey pump of 10 HP (Each).
iii) One Diesel Pump Controlling System
d) Single phasing preventors of suitable rating one for each motor.
e) Rotary type Auto/Manual/ ON/OFF selection switches.
f) One 96 mm square panel type voltmeter reading 0-500 V with rotary selector switch for reading voltage between phases.
g) One 96mm square panel type Amp. meter reading 0-500 Amp. for main fire pump and sprinkler pump.
h) One 96mm square panel type Amp. meter reading 0-500 Amp. for each Jockey pumps.
i) Appropriate etched plastic plate for each starter/switch.
j) Colour coded internal wiring from incoming main to bus bar, switch gear, starters, meters indicating lamp etc., complete in all respects.
209 A/R Providing and fixing heavy duty Aluminum armored cables 1.1 KV grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects.
a) Power cable 3 core 16 Sq.mm each 60 60.00 390.00 23,400.00
b) Power cable 3 core 25 Sq.mm each 80 80.00 760.00 60,800.00
V Fire Alarm System
210 17.2/ E&M DSR-22 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications.
211 17.1.2/E&M DSR-22 Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. each 130 130.00 1141.00 148,330.00
212 17.2.7/E&M DSR-22 Supplying, installation, testing & commissioning of fault isolator complete with base as required. each 9 9.00 3257.00 29,313.00
213 17.2.14/E&M DSR-22 Supplying, installation, testing & commissioning of addressable manual call point complete as required. each 9 9.00 3859.00 34,731.00
214 17.2.15/E&M DSR-22 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required each 10 10.00 3494.00 34,940.00
215 17.5.3.2/E&M DSR-22 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm rm 2450 2450.00 85.00 208,250.00
VI Automatic Sprinkler System
216 21 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
21.2 Upright Sprinkler each 113 113.00 408.00 46,104.00
VII Fire Extinguishers
217 A/R Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket. each 6 6.00 6126.00 36,756.00
218 A/R Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
1.0 Interior works
219 SOR-22 26.27 Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. Thesystem should rest on periphery walls /partitions with the help of GI perimeter wall angle of size24x24X3000 mm made of 0.40 mm thick sheet, to be fixed to the wall with help of plastic rawl plug at 450 mm centre to centre & 40 mm long dry wall S.S. screws. The exposed bottom portion of all T-sections used in false ceiling support system shall be pre-painted with polyester baked paint, for all heights. The work shall be carried out as per specifications, drawings and as per directions of the engineer-in-charge. 0.00
26.27.1 With 16 mm thick beveled tegular mineral fibre false ceiling tile (NRC 0.55 to 0.6) sqm 936 936.00 1832.40 1,715,126.00
220 Derived/P-1 Providing, fittings & fixing vertical venetian blinds (of vista, mac make) to window made with aluminium slate or approved thickness, colour quality with all accessories including adjuster, hardworks complete with all labour and materials in all floors.Design and colour to be approved first by Engineer-in-Charge. Sqm 190 190.00 1479.00 281,010.00
221 21.1 SOR-22 Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868,(Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,.Aluminium snap beading tor glazing/paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.) 0.00
21.1.1 For fixed portion 0.00
21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) kg 1603 1603.00 426.90 684,321.00
222 21.1.2.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) kg 1336 1336.00 480.00 641,280.00
223 21.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 0.00
224 21.2.2 Pre-laminated particle board with decorative lamination on both sides sqm 234 234.00 826.90 193,495.00
225 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 0.00
21.3.3 With float glass panes of 8 mm thickness Sqm 100 100.00 1285.60 128,560.00
Low height partition 0.00
226 21.1 Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868,(Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,.Aluminium snap beading tor glazing/paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.) 0.00
21.1.1 For fixed portion 0.00
227 21.1.1.3 Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) kg 552 552.00 426.90 235,649.00
21.2 Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. 0.00
228 21.2.2 Pre-laminated particle board with decorative lamination on both sides sqm 41 41.00 826.90 33,903.00
229 21.3 Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber /neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): 0.00
21.3.3 With float glass panes of 8 mm thickness Sqm 28 28.00 1285.60 35,997.00
230 Derived Providing & fixing brass dripry rod of 1.5 mm thick & 25 mm dia with brass plate and both side round end bracket for fixing curtains to doors of branded curtain fabric manufacturer (i.e. Bombay Dying) Complete with nailes etc. as per selected by client / E.I. Mtr. 57 57.00 841.00 47,937.00
231 Derived Providing & fixing of Aluminium Framed preliminated painted board complete wirth fixing of room no. / name plate / exit route in Hostel rooms & chambers of Institute block and hostel as per choice of client / E/I each 50 50.00 238.00 11,900.00
2.0 Fixed Furniture 0.00
232 Derived Full height storage (size : 1200 L x 1975 H x 600 D) for Record room Making, supply and installation of Wooden Wardrob, 600mm deep, the sides, Top of B.W.P. lesard with 1.0 mm laminates finish. 12 mm thick B.W.P. Ply The front shutter with 19 mm thick B.W.P. Ply wood of century ply or equivalent with 1.0 mm thick. laminates movable roller, channel, recess knob Itallica Locks glass etc. including all fitting & fixture shall be complete in all respect. as per drawing and direction of E/I. each 14 14.00 19351.00 270,914.00
233 Derived Storage Unit Low Height for Officer chamber (size :1050L x 430W x 750H) Supply , Fabrication and Installation of low height storage unit. The structure of made out of 18mm thick pre-laminated board (PLB). The shelves are made out of 18mm thick (PLB) , which are adjustable in height. The shutters are made out of 18 mm (PLB) openable and fitted by hinges, recessed handles, locking unit and levelers are considered, all complete as per drawing and directly of E/I. Nos. 35 35.00 9873 345,555.00
234 Derived Information Desk : (3775 x 750 x 900 h) Supplying and fixing Information Desk made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I. each 2 2.00 43556 87,112.00
235 Derived Interaction Countre : Size (4200 mm x 750 x 900 H) Supplying and fixing Interaction Countre made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I. Nos. 2 2.00 58064 116,128.00
3.0 Loose Furniture 0.00
236 Derived Coffee Table / Centre Table (size : 1100 x 600 x 450mm) Supply, Fabrication & Installation of 2nd classTeak wood polished frame with glass top Complete as per drawing and selected by client / E.I Nos. 5 5.00 6969.00 34,845.00
237 Derived Side table (size : 510 x 440 x 450mm) Supply,Fabrication & Installation of side table made of prelaminated board top matched with bed finish , with all necessary fixtures and fittings complete as per drawing and direction of E/I. Nos. 6 6.00 2764.00 16,584.00
238 Derived Canteen Table (size : 900x900) - Supply, Fabrication and installation of rectangular table of size (900 x 900 x 750 H) with preliminated Particle board top over chrome base leg all complete as per drawing design and direction of E/I. nos. 8 8.00 12272 98,176.00
239 Derive Dining Table (Dining room of Guest House) - Size : (2000 x 800 x 750 mm H) - Supply Fabrication & Installation of Dining Table top of 19 mm thick PVC laminated board with 2 mm thick PVC edge banding , supported with M.S Rolling sqaure section framed complete with all fittings and assessories as per drawing & direction of E/I. nos. 1 1.00 12196 12,196.00
240 Derive Meeting Table / Confrence Table - 22 persons Size : (5400 mm x 750mm x 900mm Ht.) 0.00
Providing & making meeting table of given size made of 25 mm thick block board as per IS code 303with 1.0mm thick laminate at top and 1-1/2" Teak finish beading on all the sides with proper niche in between beading and laminate edge 25mm thick round laminated pedestal and wooden frame work 75 x 62mm Teak wood bracket as top support including polishing of wooden frame work and all complete as per drawings and direction of E/I. Each 1 1.00 58073 58,073.00
241 Derive Executive table with return unit – 0.00
Supply fitting & fixing Table top is made of 25 mm prelaminated boards with 2 mm PVC edge banding, supported on 25 mm thick gable ends and 18 mm PLB with modesty panels, pedestal are made of 18 mm thick PLB with two drawer units and sliding keyboard tray and one filing unit. The drawer unit are made of mobile with the use of castors.The drawer unit s are provided with suitable locks and all hardware complete as per drawing design and direction of E/I. Each 8 8.00 35626 285,008.00
242 Derive Sr.officers Table (size : 1350 x 750 x 750 mm) 0.00
Supply fitting & fixing Prelaminated particle board of wood finish on both side and top on hard wood frame with drawer, Cabinet and wire manager complete with all necessary hardware and chrome handle , as per drawing and direction of E/I. Each 34 34.00 17570 597,380.00
243 Derive Works station / Computer table (Size 1050 x 450 x 750mm (H)) Supply of Computer table made of 25 mm thick pre laminated particle board work top the tables will be lipped with PVC edge band of 2.0 mm thickness with frames : 50 mm thick and 1050 Ht , Base 700 mm five pronged base is made out of GF nylon - 6with an embedded metal rings and bottom ribs for additional support and strength lockable drawer unit and CPU stand wire manager at Top complete as per drawing design and direction of E/I. Nos. 68 68.00 10454 710,872.00
244 Derive Supplying, Fitting and Fixing of 3 seater chair (Chrome) 0.00
Made of Cushion with high density cold cured self -skinned pre -moulded foam of 50-60 density the shape of plywood. Upholstery is done by using high-pressure pneumatic spray glue and pneumatic press over chrome base & legs as specify by manufacture all complete as per direction of E/I. Each 8 8.00 18003 144,024.00
245 Derive Supplying, Fitting and Fixing of Officer's Chair (Medium back) - 0.00
Click Medium Back Chair with Single point lock , Synchronized Tilting mechanism , Gaslift for height adjustability, Fixed Arms and chrome 5 prong base and twin wheel castors all complete as as per direction of E.I. Each 34 34.00 19177 652,018.00
246 Derive Supplying, Fitting and Fixing of Computer staff / visitor's chair (low back) - 0.00
The frame is made out of Dia 25.4 mm tube of 16 gauge, welded by Co2 welding process for uniform surface finish and higher tensile strength perforation on the sheet is of uniform 2.5 mm dimension and gives good ventilation . all comp as selected by E.I. Each 227 227.00 4024 913,448.00
247 Derive Dining Chair - Supply , Fabrication and installation of dining chair with solid beech wood frame and legs with melamine polish. The seat and back rest shall be fully uphole stered with leatherlite / Fabric finish All complete as per drawing design and direction of E/I. Nos. 12 12.00 2555 30,660.00
248 Derive Dining Chair (Stackable ) for Canteen & SHG Hall - Plastic Seat & BAck Without Arms and with Powdercoated Legs 'Providing and Fixing Featherlite Make MAGNA Chair The frame is made out of 22mm tube of 16gauge tube Welded by Co2 welding process for uniform surface, Thermo set powder coating epoxy polyester hybrids of harness (pencil) H.B.74 and impact resistant (in lab) 60-160 kgs cm and to a thickness of 40-50 microns is carried out of 7 step pretreatment process. The Back Shell is made out of Talc filled 10% poly propylene co polymer molded with ergonomic see through design Nos. 152 152.00 1278 194,256.00
249 Derive Godrej reception table size 2410x1065x725 work surface. Nos. 2 2.00 43556.00 87,112.00
250 A/R Cantilever chair nos 75 75.00 5489.00 411,675.00
251 A/R Table with side unit return nos 2 2.00 63883.00 127,766.00
252 A/R Compactor nos 8 8.00 91962 735,696.00
Total Rs. 97,184,645.00
(A) Non Shedule Items Amount- 7,242,571.00
(B)Shedule Items Amount- 89,942,074.00
(C) Applying Corrcetion Factor 0.982 on Schedule item(SOR) on Sl. No. (B)- 88,323,117.00
D=Add Extra GST 5.36% of (C) 4,734,119.00
ELECTRIC 22,256,089.00
Executive Engineer
Building Division Aurangabad
BILL OF QUANTITY
Provision of Electrical Wiring & Electrical Installation in the Proposed Block Office Building for Rural Development Department
SL.No Code Details of Items Qty Rate Unit Amount
1 1.3.3 Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable size G.I box etc. as required. Group - 'C'
Light Point -531 733 1146.00 Point 840,018.00
Fan/Wall Fan Point/Exhaust Fan - 187
Call Bell Point - 15
1.59 Wiring for group controlled (looped) light point/ fan point/ exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit etc as required.
2 1.5 Wiring for light/ power plug with 2 X 4 sq. mm FRLS PVC insulated copper conductor single core cable in surface / recessed PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 1185 309.00 Metre 366,165.00
3 1.7 Wiring for circuit/ submain wiring along with earth wire with the following sizes FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire (For circuit & street light) 2200 201.00 Metre 442,200.00
1.7.2 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Computer Terminal) 1365 246.00 Metre 335,790.00
1.7.3 2 X 4 sq. mm + 1 X 4 sq. mm earth wire(For AC) 900 309.00 Metre 278,100.00
1.7.11 4 X 6 sq. mm + 1 X 6 sq. mm earth wire(For LDB & CDB) 375 660.00 Metre 247,500.00
1.7.12 4 X 10 sq. mm + 1 X 6 sq. mm earth wire(For PDB) 325 925.00 Metre 300,625.00
4 1.25 Supplying and fixing two module stepped type electronic fan regulator on the existing modular switch box including connection but excluding modular plate etc. as required. 148 358.00 Each 52,984.00
5 1.31 Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess including providing and fixing 5 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch, connection, painting etc, as required. 70 414.00 Each 28,980.00
6 1.32 Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin, 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch connection, painting etc, as required. 79 531.00 Each 41,949.00
7 1.33 Supplying and fixing 2 pin, 5 amp. ceiling rose on the existing junction box/PVC box including connection etc as required. 217 64.00 Each 13,888.00
8 1.34 Supplying and fixing batten/angle holder including connection etc. as required. 151 80.00 Each 12,080.00
9 1.37 Supplying and fixing Ding-Dong call bell suitable for single phase, 230 volts complete as required. 15 240.00 Each 3,600.00
10 1.27 Supplying and fixing following modules G.I. box along with modular base and cover plate for modular switches in recess etc as required.
11 1.53 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 25 amps modular socket outlet and 25 amp modular SP MCB 'C' curve, including connections, painting etc. as required. 60 683.00 Each 40,980.00
12 1.56 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 nos. 5 pin 5/6 amps modular socket outlet and 2 nos. 5/6 amps modular switch, connection etc. as required. 91 778.00 Each 70,798.00
13 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.6 8 way, Double door (for Building street light) 1 2591.00 Each 2,591.00
14 2.9 Supplying and fixing following way three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required. (But without MCB / RCCB / Isolator)
2.9.1 4 way ( 4 + 12 ), double door, horizontal type 28 4184.00 Each 117,152.00
15 2.12 Supplying and fixing following rating, 240 volts, ‘C’ series, miniature circuit breaker suitable for lighting and other loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6A to 32A amps, single pole 342 237.00 Each 81,054.00
2.12.2 6A to 32A amps, SPN 1 606.00 Each 606.00
2.13.3 40A to 63A amps, double pole (for UPS DB,s) 6 1198.00 Each 7,188.00
16 2.4 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc. as required.
17 2.34 Supplying and fixing following ways, surface/recess mounting, Vertical three phase distribution board ( VTPN DB's ) of CRCA sheet steel, dust protected, duly powder painted suitable for upto 250 amp, four pole MCCB as Incomer and SP/TP MCB's as outgoing inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB's etc as required. (but without MCCB & MCBs),Legrand/Scneider.
2.33.2 6 way, Double door, I/C 250A, MCCB 6 20954.00 Each 125,724.00
18 5.1 Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required. 15 521.00 Each 7,815.00
19 5.7 Supplying and fixing recess/surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
20 5.8 Supplying and fixing surface mounted following types LED downlighter with minimum efficacy 100 lm/w in pressure die-cast aluminium housing and integrated electronic driver etc directly on ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor cable etc as required.
21 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
22 6.1 Supplying and fixing of following types lamp in the existing electrical fitting/ fixtures etc. as required.
6.1.6 15 watt LED lamp 151 250.00 Each 37,750.00
23 8.15 Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required. 148 2482.00 Each 367,336.00
24 8.17 Supply and installation of following sweep/ sizes metallic blade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc as required.
25 8.18 Supply and fixing of following sweep/ sizes PVC/ABS square body Exhaust Fan with automatic openable louvre shutter in existing opening including making connection, testing etc as required.
26 8.20 Supply and installation of 600 mm, 230 V A.C. wall mounted Air circulator, heavy duty fan including fixing the bracket, making connection, testing, commissioning etc as required. 3 9941.00 Each 29,823.00
27 8.5 Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV/ HPSV/ LED street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. 11 1038.00 Each 11,418.00
28 7.7 Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.9 50 sq.mm, 3.5 core (for VTPN DB) 240 561.00 Metre 134,640.00
29 7.1 Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.2 Above 35 sq. mm and upto 95 sq. mm 130 326.00 Metre 42,380.00
30 7.4 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.2 Above 35 sq. mm and upto 95 sq. mm (clamped with 25X3mm thick saddle) 100 109.00 Metre 10,900.00
31 3.15 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 2 13721.00 Set 27,442.00
32 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc as required. 30 144.00 Metre 4,320.00
a 8.11 Supplying and fixing of fabricated Electrical control panel of cubical construction, floor/wall mounted type, fabricated out of 16 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated painting of approved shade after 7 tank treatment process, cable alley internal wiring, earth terminals, Bus bar Chamber, Insulator and complete in all respect etc and panel manufacturers must be approved by CPRI. (But without RYB inicator , ammeter, voltmeter, inter-connection copper conductor cable / solid copper strip, switchgears etc. 40 1809.00 dd 72,360.00
b 2.4 Supplying and fixing of following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections etc.as required.
c 2.7 Providing and fixing following capacity four pole ON-load/ panel mounted changeover switches inside the existing cubical panel board including drilling holes in cubicle panel, making connections etc. as required.
d 2.13 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.13.1 6 A to 32 A, double pole 2 667.00 Each 1,334.00
e 7.9 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
f AR 50 mm X 5 mm copper strip (2.30 Kg/mtr) 25 871.00 Kg 21,775.00
g 8.13 Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required. 1 6536.00 Each 6,536.00
h 2.2 Providing and fixing MV danger notice plate of 200mm x 150 mm made of mild steel at least 2mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side etc as required. 1 214.00 Each 214.00
34 1 FIRE SUPPPRESSION SYSTEM
(ii) NS SITC lienear pneumatic heat Detection. 20 3684.00 Mtr 73,680.00
(iii) NS SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire). 1 27289.00 No 27,289.00
2 Safety Accessories and Misc.
(i) NS Rubber mat of 16 mm thik and 1000mm wide to with stand 15kv dielectric strength as per is 5424.1969 15 2208.00 Metre 33,120.00
(ii) NS Shock treatment chart in English and local language duly framed with glass. 4 696.00 nos 2,784.00
(iii) NS First aid box complete with all standard first aid materials. 2 602.00 nos 1,204.00
(iv) NS Rubber gloves 11 KV grade as per IS 4770-68 2 401.00 pairs 802.00
(i) 3.4 Earthing with G.I. plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with salt and charcoal / coke as required. 2 6884.00 Set 13,768.00
(ii) 3.11 Supplying and laying 25 mm X 5 mm G.I. strip in 40 mm dia G.I. pipe from earth electrode, including connection with G.I. nut, bolt, spring, washer excavation and refilling etc. as required. 10 721.00 Meter 7,210.00
(iii) 3.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 10 195.00 Meter 1,950.00
FOR LIGHTNING ARRESTER
35 4.2 Providing and fixing lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 6 416.00 Each 2,496.00
36 4.4 Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required. 50 81.00 Each 4,050.00
37 4.7 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For horizontal run) 170 102.00 Metre 17,340.00
38 4.8 Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. ( For vertical run) 30 145.00 Metre 4,350.00
39 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 6 6323.00 Set 37,938.00
40 3.9 Supplying and laying 25 mm X 6 mm G.I. strip at 0.50 metre below ground as strip earth electrode, including connection/ termination with GI nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping with 2 sets of G.I. nut bolt & spring washer spaced at 50 mm) 90 133.00 Metre 11,970.00
FOR CAMPUS LIGHT
41 8.22 Supply and erection of 6 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
42 9.16 Providing and making of following sizes octagonal street light pole foundation in reinforced cement concrete 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size ) of specified size including PVC conduit, form work, curing, reinforcement, excavation and refilling etc. as required.
9.16.2 For 6/7 metre pole (500mm X 500mm X 1400mm) 25 4398.00 Each 109,950.00
43 5.14 Supplying and fixing following types LED street light with minimum efficacy 100 lm/w in die cast aluminium housing, toughened glass, IP 66 protection and complete with electronic driver etc on pole/building including connection earthing the body etc as required.
44 7.7 Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
45 7.1 Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
46 3.2 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required. 2 6323.00 Set 12,646.00
47 3.7 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing etc. as required. 625 53.00 Metre 33,125.00
48 3.16 Supplying and connection of following sizes ISI marked FR PVC insulated, single core copper conductor cable etc as reqd.
EXTERNAL LIGHT FEEDER PILLAR
49 NS Fabrication, supply, Installation testing and commissioning of Street Light Feeder Pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, digital ammeter & voltmeter, RYB LED lamp, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals etc. complete in all respect, suitable for following incoming and Outgoings as required. (CPRI Approved Panel Mfg.) 1 58006.00 Each 58,006.00
63 A, 4P MCCB, 16 KA with spreader, Rotary Handle - 1 No. (As Incomer)
16 A, 2P MCB, 10 KA - 4 No. ( As outgoings )
40 A, TPN MCB, 10 KA - 2 No. ( As outgoings )
Power Contactor - 40 A - 1 No.
Astronomical Digital Time setting for 24 hours cycles - 1 No.
SUBSTATION, CABLE AND FEEDER PILLAR
50 Supply, Installation, testing & commissioning 200 KVA, 11 K V / 433 V, 50 Hz, 3 phase Delta / Star connected, copper wound ONAN Transformer with Dyn-11 vector group suitable for out-door, floor mounting. The transformer shall have OFF Load taps in steps of +/- 2.5 % and +/-5 %, complete with first fill of oil and shall conform to I S : 2026 - 2011 & IS : 1180 (Level-2) : 2014 (latest edition). H. T. & L. T. sides of the transformer shall be suitable for cable termination box / Busduct Termination box complete with cable end-boxes as follows: Make:-kotsons/Powerstar /kirloskar/crompton HT SIDE: 11 KV ,3C X120MM XLPE CABLE ,LT SIDE:,2 X 3.5 X185 Sq. mm. XLPE CABLE Transformer shall have provided with winding over temperature indication and trip devices. 1 562723.00 Set 562,723.00
51 NS Supply ,Installation, testing and commissioning of 2 Pole mounted DP providing I no 11kv,400A GOC in accordence with ie rules& local authority specifications and drawing and comprasing the following
2 nos of 11 mtr long MS pole complete with pole, excavation, MS foundation and back filling complete as required.
AB switch, Horn gap, HT fuse set, Lighting Arrester Set, Pole Stay wire 4set, required chanel complete etc as required. 1 192500.00 Set 192,500.00
52 NS Supply, Installation, testing and commissioning of silent type DG set comprising with diesel engine water cooled , synchonous alternator , AMF panel three phase , acoustic enclosure, battery with charger and related accessories, including PCC 1:2:4 platform, incoming cable 10 meter, earthing GI/CU plate 2 nos. including exhaust pipe B class with insulation as per CPCB IV+ norms etc as required. Make:- Kirloskar/ Ashok Leyland/Cummins.
Capacity - 125 KVA 1 1441246.00 Each 1,441,246.00
53 7.8 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power H.T. cable with aluminium conductor for working voltage upto 11 KV as required.
54 7.5 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 11 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
55 7.7 Supply of following sizes and core XLPE/PVC insulated PVC sheathed (Heavy duty) armoured electric cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.8 35 sq.mm, 3.5 core (For External Light feeder Pillar) 100 415.00 Metre 41,500.00
7.7.11 95 sq.mm, 3.5 core (For Generator Line) 90 950.00 Metre 85,500.00
56 7.1 Laying of one number PVC insulated and PVC sheathed/ XLPE power cble of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc. as required.
7.1.2 Above 35 sq. mm and upto 95 sq. mm 90 326.00 Metre 29,340.00
7.1.2 Above 95 sq. mm and upto 185 sq. mm 180 336.00 Metre 60,480.00
57 DSR/10.5 Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
58 DSR/9.1 Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required.
59 9.15 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as required. In the existing trench, complete as required.
9.15.1 63 mm dia (OD-63 mm & ID-51 mm nominal) 30 202.00 Metre 6,060.00
9.15.2 90 mm dia (OD-90 mm & ID-76 mm nominal) 25 250.00 Metre 6,250.00
9.15.3 120 mm dia (OD-12 mm & ID-103 mm nominal) 20 327.00 Metre 6,540.00
60 3.4 Earthing with G.I. earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. (For Transformer Neutral and Feeder panel) 6 6884.00 Set 41,304.00
61 3.6 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe 2.7 metre long etc. with charcoal/ coke and salt as required. 4 13721.00 Set 54,884.00
62 3.14 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 60 1180.00 Metre 70,800.00
63 3.15 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 90 195.00 Metre 17,550.00
64 NS Suuply, Installation, testing and commissioning of a fully enclosed type 100 KVAR capacitor panel, dust vermin and IP 55 protected, fabricated out of 14 guage MS sheet duly DPC coated including interconnections, relays specified as below complete as required. 1 271000.00 Each 271,000.00
1 No. 200 amp TP MCCB of 36 KA service breaking capacity.
6 No. 63 Amp TP MCB of 16 KA service breaking capacity complete with phase indicating lamps, voltmeter and ammeter with selector switch.
4 Nos. 15 KVAR & 2 Nos. 20 KVAR MPP type capacitors with associated 63 Amp TP MCCB AC3 duty contactors with each capacitor bank and 6 step relays for automatic and manual operation of capacitors, necessary indication lmps/toggle switch etc and required inter connectionscomplete job as required.
65 NS SITC of 2MP IR Bullet Fixed lens Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S), support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. (Approved Makes: Hikvision/ Honeywell/ Bosch) 4 5250.00 Each 21,000.00
66 NS SITC of 2MP IR Indoor Dome Fixed lens Camera- 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, Color: 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Tripple individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, IK10, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection, video tampering, UL, CE, FCC certified. (Approved Makes: Hikvision/ Honeywell/ Bosch) 18 5150.00 Each 92,700.00
67 NS SITC of 2MP IR Outdoor PTZ Camera - 1/2.8" Progressive Scan CMOS, 1920 × 1080 at 60fps, 4.8 mm to 153 mm, 32× Optical, 16x digital zoom, Color: 0.005 Lux at F1.6, B/W: 0.001 Lux at F1.6, ICR, ONVIF, support H.265,MJPEG, 120 dB WDR, 3D Digital Noise Reduction, HLC, BLC, Defog, EIS, Tripple individually configurable stream, 24 VAC & Hi PoE, IR range: 150m, Pan: 360° endless, Tilt: From -15° to 90° (auto-flip), Pan Speed - from 0.1°/s to 160°/s, Preset Speed: 240°/s, Tilt Speed- from 0.1°/s to 120°/s, Preset Speed: 200°/s, Presets- 300, Alarm Input-2-ch alarm input, Alarm Output-1-ch alarm output, Audio-1 channel input & output, Support on-board storage up to 256 GB (SD card not included), IP66, IK10, Face Detection, Intrusion Detection, Line Crossing Detection, Region Entrance Detection, Region Exiting Detection, UL, CE, FCC certified. (Hi-PoE injector under Si Scope, if PoE is used)(Vertical Pole Mounting Bracket)) (Approved Makes: Hikvision/ Honeywell/ Bosch) /Equivalent 1 64200.00 Each 64,200.00
68 NS SITC of 32ch Network Video Recorder - Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. (Makes: Hikvision/ Honeywell/ Bosch) 1 42600.00 Each 42,600.00
69 NS SITC of 6TB Surveillance Hard Disk Custom-built for surveillance applications with Image Perfect firmware for crisp, clear, 24×7 video workloads Maximum 180TB/year workload rating—3× the workload rating of desktop drives—for reliable performance in write-intensive surveillance systems Rotational vibration (RV) sensors help maintain performance in RAID and multi-drive systems (4TB or higher) Up to 10TB of capacity to store up to 10,000 hours of HD video (Approved Makes: Seagate/WD/Toshiba) 1 18850.00 Each 18,850.00
70 NS SITC of SWITCH PORTS: 16-Port 10/100/1000 + 2 x 1GE copper/SFP combo. Fixed-configuration 1RU x 1/2, half-rack width chassis, 16 x RJ45 10/100/1000 BaseT PoE+ ports 2 x SFP/RJ45 combo ports 2 x SFP ports, 1 x USB port (type A, USB 2.0), 1 x Console port (RS232 RJ45)IEEE 1588v2 capable ports 12, MACsec capable ports 12 Switch capacity 24 Gb/s, PoE power budget 115W, Includes power cord & manuals/software access cards, Includes RJ45 to DB9 adaptor Operating temperature: -10°C to 60°C (14°F to 140°F) Storage temperature -40°C 3 26500.00 Each 79,500.00
71 NS SITC OF Video Management Software equips users with live video from the camera feed, access control, video intercom, alarms, and data storage. Support upto 120 Camera Streaming. Abundant Modules – Video, access control, attendance, intercom, alarm, E-map, and more. Friendly User Experience and Visual Design – Lightweight, flat UI, and component-based design. Multiple-Languages – 33 languages, including English, Simplified Chinese, Arabic, etc. 1 19500.00 Each 19,500.00
72 NS SITC OF Server for Video Management Software Form Factor: 1U rack, Processor: 1x Intel® Xeon® processor E-2300 or 1x Intel® Pentium® processor GPU Support: NVIDIA Quadro T1000 PCIe Active GPU, Memory: Up to 128GB in 4x DIMM slots, Drive Bays: Up to 10x 2.5 inch hot-swap SATA/SAS drives or 4x 3.5-inch hot-swap SATA/SAS drives Expansion Slots: Up to 2x PCIe Gen4 x8 slots 1 85000.00 Each 85,000.00
73 NS SITC OF 43” Professional display rated for 16/7 operation with essential professional functions Screen Size 43, Brightness (cd/m²) 350, Contrast Ratio 1200:1, Dynamic Contrast, Ratio 400,000:1, Response Time (ms) 8.0, Display Resolution, (H x V, pixels) 3840 x 2160, HDR (High Dynamic Range) compatibility yes (HDR10, HLG) 2 51600.00 Each 103,200.00
74 1.58 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required.
1.58.1 1 run of cable 1500 52.00 Metre 78,000.00
75 NS Supply , Installation , Testing and Commissioning of 12U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Makes: Poweride/MTS/Rittal/APC/APW 1 18600.00 Each 18,600.00
76 NS SITC of 6 U network Rack 3 9800.00 Each 29,400.00
77 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
LAN & WIFI SYSTEM
78 1.58 Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed PVC conduit as required.
1.58.1 1 run of cable 4500 52.00 Metre 234,000.00
79 1.21 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.
80 NS Supply , Installation , Testing and Commissioning of CAT6 information outlet (I/O) for Data, Voice, Camera & Wi-Fi at user end. Makes: Belden/Siemon/Panduit/Leviton 100 350.00 Each 35,000.00
81 NS Supply , Installation , Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end.Makes: Belden/Siemon/Panduit/Leviton 5 4500.00 Each 22,500.00
82 NS Supply , Installation , Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. Makes: Belden/Siemon/Panduit/Leviton 100 310.00 Each 31,000.00
83 NS Supply , Installation , Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity.Makes: Belden/Siemon/Panduit/Leviton 100 350.00 Each 35,000.00
84 NS Supply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. Makes: Belden/Siemon/Panduit/Leviton 100 45.00 Each 4,500.00
85 NS Supply , Installation , Testing and Commissioning of 22 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Makes: Netrack/MTS/Rittal/APC/APW 1 27200.00 Each 27,200.00
86 NS Supply , Installation , Testing and Commissioning of 9 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Makes: Poweride/MTS/Rittal/APC/APW 3 12500.00 Each 37,500.00
87 NS Supply , Installation , Testing and Commissioning of Core Switch Port Density - 14 X 1/10G SFP Ports and 12 X 1/10G Base T 2 x 40/100 G QSFP28 Ports. Power Supply - Redundant Hot Swappable Power Supply - AC/DC, Virtual Chassis/ Stacking Option - Upto 6 Switches or more, RAM - 8 GB or better, Flash and Buffer - 32GB or better and 32MB Packet Buffer Switching Capacity and forwarding Rate, 900 Gbps or better and 650 Mpps or better , Latency & MTBF Latency: <650 ns MTBF: 384,636 h,MAC Address 64K, Routes IPv4 - 12k or better, IPv6 - 12k or better. Support for Egress rate limiting, Eight egress queues per port, IEEE 802.1Q, 802.3x, DiffServ, Jumbo frame. Protocol Support - IGMP Snooping V1, V2, V3, MLD, PIM-SM/PIM-SSM/PIM-DM/PIM-Bidirectional, DVMRP,RIPv1v2,RIPing ,OSPFv3, RIP, BGPv4, MP-BGP,GRE, IS-IS, ITU-T G.8032, IEEE 802.1s, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP), Ipv4/Ipv6, DHCP Option 82, BPDU, STP Root Guard, SIP detection, SPB-M or MPLS, IEEE 802.1ae, MIB, NTP,Built-in CPU protection against malicious attacks,The Switch Should have 1+N redundant supervisor manager in Virtual chassis with In-Service Software Upgrade (ISSU), VXLAN, ARP Poisioning detection, Policy based routing (PBR),SDN support through Restful API and openflow 1.3.1, Management SNMP V1,V2,V3, Web GUI, CLI, USB or equivalent memory card, IPv6 management feature on open standards, IEEE802.1ag, TDM or equivalent standards 1 572500.00 Each 572,500.00
88 NS Security Should support Access Control Lists (ACLs), DHCP snooping, IEEE802.1x based port authentication, RADIUS/ TACACS+, SSL, SSH, port mirroring,NTP, IEEE 1588, AES, Syslog, MD5, LLDP-MED, BPDU Blocking, BFD, Unified management, control and fabric-mesh virtual chassis technology, Autosensing IEEE 802.1X multi- client, multi-VLAN support for bridging and SPBM/VXLAN services,MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks Resiliency IEEE802.1q, IEEE802.1d, IEEE802.1s, IEEE802.1w, ITU-T G.8032 ring resilience/ring protection, VRRPv2, Operating Temperature and Humditiy Temperature: 0 to 45Deg Humidity: 5% to 95% (non-condensing) Safety Certifications CE, EN 55022, RoHS, US UL 60950, CSA22.2 , FIPS 140-2, EAL2 & NCPP Certified , EN 60825-1/2 Laser SFP , SFP should be of same make as switch. Vendor to be present in Gartner Magic Quadrant. The Switch shall work with on-premise and cloud based NMS without change in hardware/software/OS Image. The Switch should be EAL2/NDPP certified Cisco/Juniper / Alcatel-Lucent
89 NS Supply , Installation , Testing and Commissioning of Access switch Port Density 24 X 1G RJ-45 Ports 2 x 1G/10G SFP+ Ports and 2 x 1G SFP/Base-T Combo Ports Power Supply Internal Power Supply Virtual Chassis/ Stacking Option Upto 4 Switches or more RAM 1 GB or better Flash 1 GB or better Switching Capacity and forwarding Rate 92 Gbps or better and 68 Mpps or better Latency & MTBF Latency: < 4 µs MTBF: 2595 k hours Layer 2 Features Mac Address:16K or more VLAN: 4K or more System Policies: 1.5K or more Max Jumbo Frame: 9216 bytes Multicast Group: up to 1000 Quality of Service Auto QoS for switch management traffic,Policy-based QoS, Traffic Prioritization, Priority Queues: Eight hardware-based queues per port, SPQ, WRR 5 86800.00 Each 434,000.00
90 NS Protocol Support Static Routing, MSTP, RSTP, PVST+,IPv6 Tunneling, LACP, LAG, IGMPv3, DHCP, DHCP82,DHCP Relay for IPv4/IPv6,Multiple microcode image support with fallback recovery, ARP,SDN support through Restful API and openflow 1.3.1 Management Loopback IP address support for management per service, Policy- and port-based mirroring, Remote port mirroring, sFlow v5 and Remote Monitoring (RMON), Unidirectional Link Detection (UDLD),Digital Diagnostic Monitoring (DDM), LLDP-MED, NTP,MVRP, SNMP, sflow or equivalent Security Dynamic change of authentication (CoA),MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks, Web based Authentication, Autosensing IEEE 802.1X multi-client, multi-VLAN support,RFC 1321 MD5, RFC 2284 PPP EAP,RFC 1826/1827/4303/4305 Encapsulating Payload (ESP) and crypto algorithms, RFC 2104 HMAC Message Authentication, Built-in CPU protection against malicious attacks Resiliency Unified management, control and virtual chassis technology, Virtual Chassis 1+N redundant supervisor manager, Virtual Chassis In-Service Software Upgrade (ISSU),Smart continuous switching technology, IEEE 802.3ad/802.1AX Link Aggregation Cisco/Juniper / Alcatel-Lucent
91 NS SITC of 24 Port POE Network Switch Port Density - 24 X 1G RJ-45 PoE+ Ports with 380W power budget, 2 x 1G/10G SFP+ Ports and 2 x 1G SFP/Base-T Combo Ports upgradable to 2 x 10G SFP+ Ports Power Supply - Internal Power Supply, Virtual Chassis/ Stacking Option- Upto 4 Switches or more RAM - 1 GB or better, Flash - 1 GB or better Switching Capacity and forwarding Rate - 128 Gbps or better and 190 Mpps or better Latency & MTBF - Latency: < 4 µs MTBF: 1447 k hours Layer 2 Features - Mac Address:16K or more VLAN: 4K or more, System Policies: 1.5K or more Max Jumbo Frame: 9216 bytes, Multicast Group: up to 1000 Quality of Service - Auto QoS for switch management traffic,Policy-based QoS, Traffic Prioritization, Priority Queues: Eight hardware-based- queues per port, SPQ, WRR Protocol Support - Static Routing, MSTP, RSTP, PVST+,IPv6 Tunneling, LACP, LAG, IGMPv3, DHCP, DHCP82,DHCP Relay for IPv4/IPv6,Multiple microcode image support with fallback recovery, ARP,SDN support through Restful API and openflow 1.3.1, Management - Loopback IP address support for management per service, Policy- and port-based mirroring, Remote port mirroring, sFlow v5 and Remote Monitoring (RMON), Unidirectional Link Detection (UDLD),Digital Diagnostic Monitoring (DDM), LLDP-MED, NTP,MVRP, SNMP, sflow or equivalent 1 185600.00 Each 185,600.00
92 NS Security - Dynamic change of authentication (CoA),MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks, Web based Authentication, Autosensing IEEE 802.1X multi-client, multi-VLAN support,RFC 1321 MD5, RFC 2284 PPP EAP,RFC 1826/1827/4303/4305 Encapsulating Payload (ESP) and crypto algorithms, RFC 2104 HMAC Message Authentication, Built-in CPU protection against malicious attacks Resiliency - Unified management, control and virtual chassis technology, Virtual Chassis 1+N redundant supervisor manager, Virtual Chassis In-Service Software Upgrade (ISSU),Smart continuous switching technology, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP) and static LAG groups across modules Operating Temperature and Humditiy - Temperature: 0 to 45Deg Humidity: 5% to 95% (non-condensing) Safety Certifications - CE, EN 55022, RoHS, WEEE US UL 60950, CSA22.2, FIPS 140-2, EN 60825-1/2 Laser, IEC 62368-1 SFP - SFP should be of same make as switch. Vendor to be present in Gartner Magic Quadrant. The Switch shall work with on-premise and cloud based NMS without change in hardware/software/OS Image. Cisco/Juniper / Alcatel-Lucent
93 NS SITC of WIFI Access Point Proposed solution will be Controller less/HW Controller based/SW Controller based but all the Access Points managed centralized . The WLAN solution shall propose an indoor 802.11ax Wifi 6 MU-MIMO indoor dual radio AP Access Point (2.4, 5G) AP to support 2x2:2 on 5 Ghz and 2X2:2 on 2.4 Ghz. Access Point shall offer up to 1200 Mbps throughput on the 5Ghz band (low and high bands) and up to 573 Mbps throughput on the 2.4GHz band. 2 x 10/100/1000Base-T autosensing (RJ-45) port . Both ports should support 802.3at PoE,1x USB 2.0 Type C AP should support ACL, wIPS/wIDS and DPI application, 802.11i, 802.1x Access Point shall propose a Factory reset button. Access Point shall support up to 16 SSIDs (8 per radio) with 512 Clients and should support BLE 5.1/Zigbee Integrated. Single AP can act in dual mode (WLC/Client Serving) with controller to support 256 Access Points in single cluster. Distributed Radio Management, Radio Dynamic Adjustment (RDA), Transmit Power Control @ 18 dBM(TPC), DFS, VHT20,40,80 It should support Advanced Cellular Coexistence (ACC) i.e Minimizes interference from 3G/4G cellular networks, distributed antenna systems, and commercial small cell/femtocell equipment L2 Roaming 802.11r Roaming, 802.11K, 802.11v 6 56800.00 Each 340,800.00
94 NS Operating temperature must be 0°C to 45°C Humidity must be 10% to 90% non-condensing. WFA, UL2043 Plenum rating, EMI,RoHS, REACH, WEEE
95 NS Supplying and drawing 2 pair, 0.5 sqmm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed PVC conduit as required. 1800 31.00 Metre 55,800.00
96 NS Supplying and drawing 4 pair, 0.5 sqmm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed PVC conduit as required. 400 49.00 Metre 19,600.00
97 NS Supply, installation, testing & commissioning of termination box for 50 pair EPABX system complete as required 6 1500.00 Each 9,000.00
98 NS SITC of Communication appliance for Voice,configured for:- 01 PRI- 08 Trunk- 40 Digital- 150 Analog Extensions Internal CLI on Digital Phones and Analog CLI Phones Alcatel-Lucent/Matrix/Cisco 1 165400.00 Set 165,400.00
99 NS SITC of Ananlog Phone Display type 1 line-Dot-matrix + 1 line 7-segments+ 1 line icons alphanumeric displayDate and time displayed in standby mode Call duration display Number of ringtones 1Ringtones volume levels 3 (high / low / off Handsfree function Handsfree volume control 3, Direct access memories 82-touch memories 10,Caller Identification type I & IIIncoming call log, Mute key Wall-mountable, Dialing type Tone / Pulse Protocol FSK & DTMF, Removable line connector cord RJ11/RJ11, Power supply No battery required Alcatel-Lucent/Matrix/Cisco 45 2450.00 Each 110,250.00
100 NS SITC of Console Phone Optimised access to all ALE communications features Touch screen or large display with LED buttons 3D Symphonic HD super wideband sound Cylindrical sound bar with 3D diffusion and up to 3 microphones Elegant metal and textile casing with 4 interchangeable colours Extensive connectivity: USB, WLAN, Bluetooth, IP, hybrid digital/IP Secure remote working: VPN, SRTP Accessories include: Alphabetic keypad, wireless handset, WLAN and Bluetooth module, colour display key module Centralised management and deployment from the cloud 1 9850.00 Each 9,850.00
FIRE ALARM SYSTEM
101 NS Supplying, installing, testing and commissioning of the following as per specification complete with junction box, as and where required.without JB Analogue addressable Photo Electric type Smoke Detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens 90 3950.00 Each 355,500.00
102 NS Analogue addressable rate of rise cum fixed temperature thermistor type heat detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens 6 3950.00 Each 23,700.00
103 NS Addressable type Manual Call Point complete as required. Make - Agni/Bosch/Siemens 6 7250.00 Each 43,500.00
104 NS Addressable Hooter cum strobe complete as required. Make - Agni/Bosch/Siemens 3 9450.00 Each 28,350.00
105 NS Addressable strobe complete as required. Make - Agni/Bosch/Siemens 2 8960.00 Each 17,920.00
106 NS Duct casting unit with casing of fabricated aluminium/poly carbonate and hinged inspection cover, 1 No. inlet of proper length & 1 no. outlet tube & with 1 no. analogue addressable photoelectric type Smoke detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens 1 24800.00 Each 24,800.00
107 NS Analogue addressable Fault Isolators for isolating shorted, de-wired and loose circuits between two successive Fault isolators with automatic resetting arrangement. (max. 20 devices for one fault isolators). Make - Agni/Bosch/Siemens 60 3280.00 Each 196,800.00
108 NS Analogue addressable, automatic commandable Control Switches for switching on/off various ventilation fans, pressurisation fans, zones of speakers etc. and other Fire operation related devices and complete as required. Make - Agni/Bosch/Siemens 1 6450.00 Each 6,450.00
109 NS Addressable Input Card/monitor module for connecting to Flow Switch etc. Make - Agni/Bosch/Siemens 12 7160.00 Each 85,920.00
110 NS Response indicator consisting of 16 gauge MS box with 75 x 75 x 6 thick cross brushed MS face plate. Make - Agni/Bosch/Siemens 10 240.00 Each 2,400.00
111 NS Zone address module to connect conventional zones with the addressable panel. Make - Agni/Bosch/Siemens 2 18900.00 Each 37,800.00
112 NS Providing, installing, connecting, testing and commissioning of micro processor based Logic driven Analogue Addressable Panel for below mentioned loops (each loop accessing 120 addressable detectors & 120 addressable devices). The Panel shall be able to give pin point location of all Fire/Fault conditions of addressable units via the address codes for each unit. The Panel shall also be able to automatically switch off all control switches whenever any alarm is triggered. The Panel shall have its own integrated PA System having amplifiers suitable for given no. of speaker & minimum 12 zone selector channels and have sealed maintenance free batteries of required AH capacity of 24 volts capable of running for 24 hours in normal condition followed by 60 minutes in Alarm condition with battery charger, rectifier, Loop cards, Keypad operation, L C D unit to indicate Fire / Fault Signal of individual unit, built in /external printer to log all incoming data etc complete in all respects. Software for one work station on which all graphics etc. can be viewed and providing a communication interface to the same workstation. The panel shall be provided with communication card for third party integration. Panel shall have programmable switch plates for controlling horn strobe zones/AHU shut off etc. from panel itself. Panel shall have inbuilt autodialer with minimum 6 line output. Panel shall have its own master fire fighting telephone/audio control/command centre. The Panel shall also have Logic hardware and software built into it for initiating specific AHU tripping, time delay operation of strobe, subsequent operation of electronic speakers, and finally hooters. 4 loop panel 1 380000.00 Set 380,000.00
113 NS Each loop of fire alarm panel shall have 10 to 15% spare addressable units. At all panels global access to be provided. Information of all the panel shall be accessible from any of panels through networking. All panels shall be upgradable to minimum 25% more loops. Other requirements are given in the specifications. The no. of loops may be changed based on the loop capacity of the panel. loop card. 1 140000.00 Set 140,000.00
114 NS Providing, installing, testing and commissioning of Zero Loop Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept/reset buttons for alarm address of any sensor/field device. The Repeater Panel shall provide field device address as required. The Repeater Panel shall be active & all the setting for fire alarm system can be configured with panel. 1 180500.00 Set 180,500.00
115 NS Wall mounted speaker with three tap changers in acoustically treated box with speaker and line matching transformer (2W max).(For car park & double height areas) 6 3300.00 Each 19,800.00
116 NS Ceiling mounted baffle speaker with three tap changers (2W). 50 2150.00 Each 107,500.00
117 NS Portable UL listed fire phone handsets in a suitable enclosure. 6 5750.00 Each 34,500.00
118 NS Addressable fire phone jack plates with control/monitor module. 6 2210.00 Each 13,260.00
119 NS Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 1250 120.00 Metre 150,000.00
SOLAR POWER GENERATION SYSTEM
120 DSR Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specification as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module conversion efficiency shall not be less than 16.5% PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Connections and interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kv grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories complete job etc. as required. (Including 5.36% GST) Make-Tata Power/Adani/Vikram solar/Waaree 50 64332.00 kWp 3,216,600.00
121 NS SITC of 30 KVA, 3 Ph, IGBT Based Inverter & Rectifier Both Side True Online Double Conversion UPS and M.S Powder Coated Rack & Interconnecting cable with inbuilt Phase Sequence Correction. For 30 Minutes Battery Backup using 12 Volt 65 Ah, SMF Batteries (Total 24960 VAH for 30 minutes Battery Backup). Make:- Numeric/APC/Vertiv. 1 870212.00 Each 870,212.00
ELECTRICAL LIFT- 8 PASSENGER (G + 2) MRL LIFT
Supply, Installation, Testing and Commissioning and final testing of automatic lift complete in the shaft well and pit already constructed as per CPWD Specification including automatic rescue device (ARD), all standard equipments, accessories and control equipments as per manufacture's design and as per CPWD specification (Part-III LIFTS) on turnkey basis, conforming to NBC/Statutory norms and fulfilling following requirements. (i) Type: Passenger lift. (ii) Load: As specified. (iii) Speed: 1.00 metre/sec.
(iv) Control: ACV3F, 32 bit microprocessor integrated serial communication control system with RMS (remote monitoring system)/BMS (Building monitoring system) supporting software. (v) Motor/machine: Permanent magnetic synchronous gearless motor. (vi) Operation: Simplex collective selective with/without lift attendant.
(vii) Total rise: About 3 mtrs. (approx) between two stops. (viii) Landings: All floors on same side. (ix) Floor served: As specified. (x) Signals : Digital car position indicator, car travel direction indicator inside car & at all landings, voice annunciator with suitable music shall be provided in the lift car. (xi) Shaft size: As per manufacturer's design and as per CPWD specification (Part III LIFTS), Shaft to be constructed separately.
(xii) Guide rail: As per manufacturer's specification. (xiii) Lift & Car size: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xiv) Car Entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xv) Landing Entrance: As per manufacturer's design and as per CPWD specification (Part III LIFTS). (xvi) Car door: S.S. (Stainless steel) hairline finish centre opening door . (xvii) Landing door: S.S. (Stainless steel) hairline finish centre/telescopic opening door . (xviii) Door operation: Automatic electric power operated door, full height infrared curtain with multiple criss/cross light beams. (xix) Car interior: S.S. (Stainless steel) panel with hair line finish on all sides. (xx) Car floor: Anti skid PVC flooring on heavy duty MS (mild steel) platform. (xxi) Car ceiling & lighting: S.S. (Stainless steel) finish with aesthetic appearance with LED Ceiling lights. (xxii) Car ventilation: Pressure fan/blower fan (car fan with automatic sleep timer shall be provided). (xxiii) Emergency lighting in car: Battery operated emergency lighting in the lift car. (xxiv) Intercom system: Battery operated intercom system in lift car, machine room and ground floor/control room. (xxv) Emergency alarm: Battery operated alarm bell system in lift car & control room/ground floor. (xxvi) Position of machine room: MRL (xxvii) Electric power supply: AC 415V, 3 Phases 50 Hz & AC 230 V1 Phase 50 Hz terminated in machine room.
(xxvi) Position of machine room: MRL (xxvii) Electric power supply: AC 415V, 3 Phases 50 Hz & AC 230 V1 Phase 50 Hz terminated in machine room. (xxviii) Fire man switch: Fire man switch at machine room/terminal landing. (xxix) All car panel buttons and all floor switches must be with braille language as per lift act. (xxx) Audio visual indication in the lift car showing overloading shall be provided such that doors keep open till excess load is removed. (xxxi) Spring buffer/hydraulic buffer shall be provided. (xxxii) Mechnical over speed governor, door key holes in the floor doors shall be provided. (xxxiii) Lift machine hoisting arrangement in the lift machine room and monkey ladder for lift pit should be provided by the lift agency, along with the other steel structure works, foundations for the machines etc. (xxxiv) In the hoist way fascia plate shall be provided. (xxxv) Permanent wiring in lift machine room and lift well with proper no. of light points, with fixtures, exhaust fan, plug points and 3 phase 440V power supply shall be made in lift shaft by the department, machine room or at desired level. (xxxvi) Car top safety barricade shall be provided. (xxxvii) ARD (automatic rescue device): Solit state inbuilt automatic rescue device (ARD) automatically rescues passengers trapped in the lift car in between floors in the event of power failure. Automatic operation and immediate action in the event of mains failure, capable of moving the lift to the nearest landing, opens the automatic door of the lift car and floor. Sealed maintenance free battery backup with automatic charging unit and auto changeover device on mains failure. Make: OTIS/KONE/SCHINDLER/MITSHUBISHITHYSSENKRUP (With 3 year free maintanance in DLP period)
(With 3 year free maintanance in DLP period)
8 Passenger, (544 KG) (G+2) MRL LIFT 1 1991250 Job 1991250
123 2.1 Providing and fixing following capacity double pole / TP&N sheet metal switch disconnector fuse unit in the existing metal panel board with rewireable type fuses including drilling holes in metal panel, making connections etc. as required.
124 2.5 P/F following capacity busbar chamber with 4 strips of suitable size made of copper, heavy duty complete with all accessories including connections, earthing the body etc as reqd.
125 1.3 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch , modular plate, suitable size G.I. box etc as required.
1.3.2 light point- Group - B 6 p/pt. 947.00 5682.00
126 5.10 Supplying and fixing 10/12 watt LED type Bulk-head luminaire with minimum efficacy 100 lm/w in comprising of pressure die cast housing, acrylic diffuser,IP 65 protection and complete with integrated electronic driver etc directly on wall/ceiling including connections with 1.5 sq. mm FRLS PVC insulated copper conductor cable etc as required. 6 p.mtr 1275.00 7650.00
130 7.7 Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
7.7.8 35 sq. mm, 3.5 core main point to lift m/s 80 p/mtr. 415.00 33,200.00
131 7.4 Fixing for laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.
7.4.1 Upto 35 sq. mm (Clamped with 1 mm thick saddle) 50 mtr 43.00 2,150.00
132 3.21 Providing chemical/ mineral maintenance free aerthing system comprising of copper earth electrode 3 metre length and 17.2 mm outer dia along with 25 Kg earth electrode conductivity enhancing back fill mineral compound for earth electrode to fill up the excavated earth inspection pit etc. as required. 2 p/set 16675.00 33350.00
133 3.17 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing etc. as required. 60 mtr 144.00 8640.00
134 1.7 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.
1.7.1 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 60 mtr 201.00 12060.00
135 1.31 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. 6 Each 414.00 2484.00
136 2.8 Supplying and fixing following way single pole & neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus-bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
2.8.5 6 way, Single door 1 Each 2197.00 2197.00
137 2.12 Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
2.12.1 6 A to 32 A, Single pole 3 Each 237.00 711.00
Subtotal Lift (Rs.) 2126545
Total Rs. 22,256,089.00
MATERIAL STATEMENT
SL. NO. ITEM QTY. LOCAL SAND (m³) Stone Chips (m³) COARSE SAND (m³) CEMENT (m³) BRICKS (Nos.)
1 LOCAL SAND 0.00 0.00
2 Brick Flat Soling 0.00 0.00 0.00
11 kota stone flooring 20mm CP(1:4) 0.00 0.00 0.00 C7
12 kota stone in riser and skirting 12mm CP (1:3) 0.00 0.00 0.00 C8
13 ceramic glazed wall tiles 12mm CP(1:3) 31.44 0.47 0.22
14 ceramic glazed floor tiles 20mm CP(1:4) 4.33 0.11 0.04
15 vitriefied floor tiles 20mm CP(1:4) 21.25 0.55 0.19
16 vitriefied skirting 12mm CP(1:3) 0.00 0.00 0.00
17 Chequered Terrazo Tiles 20mm (1:4) 0.00 0.00 0.00
Junior Engineer Assistant Engineer Executive Engineer
Building Division A'Bad Building Division A'Bad Building Division A'Bad
GF FF SF Terrace 125mm
All kinds of soil
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Check list farwarding.pdf
NIT • 1.76 MB
Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
NIT 10 25-26.pdf
NIT • 2.33 MB
SBD NIT 10.doc
NIT • 0.87 MB
BOQ-Block-Building-Madanpur-.xlsx
NIT • 0.16 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .