Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC 133 GARFA MAIN ROAD KOLKATA 700 078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹19.3 L+₹81,600 (4.41%)Rejected-AOC 3 C DR JAGABANDHU LANE KOLKATA 700012 | KOLKATA | KOLKATA | WEST BENGAL | 700012 | L2 | Rejected-AOC Being L2 Bidder | |
| 3 | L3₹21.3 L+₹2.8 L (15.1%)Rejected-Finance | L3 | Rejected-Finance Being L3 bidder |
Tender Value
Refer Docs
EMD Value
₹42,600
Closing Date
6 Feb 2020, 5:00 pmClosed
Executive Engineer,PWD,Birbhum Electrical Division
Laldighipara, P.O. Suri Dist. Birbhum. Pin. 731101 Near Suri Sadar Hospital
Installation of CCTV, A.C machines, Geyser, Exhaust Fan at NTS, Suri Sadar Hospital, Birbhum.
2020_WBPWD_267777_1
BIRED/40/e-Q (1st call) of 2019-2020
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
NTS, Suri
Please refer Tender documents.
8 documents required · 8 mandatory
₹42,600
26 Feb 2020
22 Jan 2020
10 Feb 2020
22 Jan 2020
6 Feb 2020
22 Jan 2020
Amount
SUB-HEAD 1--DISTRIBUTION WIRING
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) partly in 20mm size PVC rigid conduit 'FR' (Precision make) [for ceiling portion only] and in 19mm bore, 3mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Modular type switch (Brand approved by EIC) fixed on Modular GI switch board complete with 2 no. suitable size “Ph & N” copper bar with top cover plate making earthing attachment fixed on wall incl. mending good damages to original finish. [only PVC Rigid Conduit on ceiling and remaining portion concealed] [Average run 9mt] [4d /E-25]
Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore,as to gs On Board [3(i)/E20]
SUB-HEAD 2-- PLUGS & SOCKETS
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [16/ E-19 ]
Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
Supply & Fixing 240 V, 25A Modular starter (Brand approved by EIC) on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
SUB-HEAD 3--BDB,PDB,VTPN, Main Switch etc.
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. Legrand make. [ 14/D-10]
6way, Enclosure (607716)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand ]
100A FP Isolator
SUB-HEAD 4-- Polythene pipe & Wires
Cutting channel of 31 mm x 31 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire fish wire incl. mending good damages to building works, 13 mm dia 3 mm thick polythene pipe without earth continuity wire [2a/E2]
Cutting channel of 40 mm x 40 mm size on masonry wall incl. S&F heavy gauge polythene pipe dia as stated below, by means of iron hooks and supplying and drawing 18 SWG GI Wire as fish wire incl. mending good damages to building works, 19 mm dia 3 mm thick polythene pipe without earth continuity wire [3a/E2]
Making holes on RCC ceiling 125 mm depth having dia of following sizes : 125 mm depth, 50 mm dia [9(b)/E-3]
Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works
150 mm x 100 mm x 65 mm [11(b)/E-4]
Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required 150 mm x 100 mm x 65 mm [12(b)/E-4]
Supplying and Drawing 1.1 KV single core stranded 'FR' PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.
4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC [1.g1/E-9]
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [1.v/E-9]
2x(2.5 sqmm)+1x(1.5 sqmm) [ 1(s) / E-9 ]
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5sqmm [9 (i)/F-5]
4 sqmm [9 (ii)/F-5]
16sqmm [9 (v)/F-5]
SUB-HEAD 5 -- FIXING OF FANS
Fixing only exhaust fan after making holes in wall as per GS (24") [ 28(e)/C-4 ]
Supply, Fabrication & Installation shutter with G I grill on wall with crowl made by G I sheet duly welded on top to prevent rain wate, and necy. bolts & nuts (6 mm dia x 62 mm long) as per direction of EIC (24") [ 32(a)/D-14 ]
SUB-HEAD 6-- SUPPLY OF FANS
Supply of Exhaust fans complete with all accessories having the following Model / Cat No. ( Make -USHA/EPC or as per choice of EIC ) 24" ( ) Speed 720 RPM [ NS ]
Supply of ceiling fans complete with all accessories having the following Model / Cat No. ( Make -USHA Stricker galaxy )
Supply of 4ft LED T-8 box type single batten with end cap complete with all accessories [ PHILIPS make cat no TMC501P1xT LED22WP3241].
Supply of Twin 4ft LED T-8 box type batten complete with all accessories [PHILIPS make cat no TMC501P 2xT LED22WP3242]].
Supply 18W LED T-8 lamp [ PHILIPS make cat no MAS LEDtube 1200mm18W865 ] on fittings.
SUB-HEAD 7 -- AC machine
Supply & Delivery of 2.0 TR Split Air Conditioner having following specification. Cooling Capacity(minimum) - 7033 Watt Minimum ISEER rating - 3.5, BEE leveling 3 Star or more (2018-19 ) IS compliance - IS 1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) Necessary copper cable (FRLS type - make : Finolex/ Havells/Polycab) - 3mtr including 16A Plug Top (iii) Wireless Remote Controller [Make: O General / Mitsubishi Heavy or As per Choice of EIC] Out door unit will be fixed on wall with heavy type wall base.Incl supply of wall base./on floor with necessary iron chair (300mm hight). fixed on roof floor.
Supply & Delivery of 1/1.1 TR Hi-wall Split Air Conditioner having following specification. Cooling Capacity(minimum) - 3800 Watt Minimum ISEER rating - 3.5, BEE leveling 3 Star or more (2018-19 ) IS compliance - IS 1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) Necessary copper cable (FRLS type - make : Finolex/ Havells/Polycab) - 3mtr including 16A Plug Top (iii) Wireless Remote Controller [Make: O General / Mitsubishi Heavy or As per Choice of EIC]
Supply & Delivery of 1.5/1.6 TR Hi-wall Split Air Conditioner having following specification. Cooling Capacity(minimum) - 5600 Watt Minimum ISEER rating - 3.5, BEE leveling 3 Star or more (2018-19 ) IS compliance - IS 1391 Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condensor Coil : Copper Operating Outdoor Temparature = 50ºC and above Power Supply - 230V,50Hz ( +Tolerrance as per applicable standard) The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrial rubber insulation - 3 mtr (ii) Necessary copper cable (FRLS type - make : Finolex/ Havells/Polycab) - 3mtr including 16A Plug Top (iii) Wireless Remote Controller [Make: O General / Mitsubishi Heavy or As per Choice of EIC]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc as per direction of EIC including S&F of necessary fixing arrangement including M S Base of appropriate size for indoor and outdoor unit, duly painted, laying and making connection of refrigeration pipe & Supply & charging of refrigerant, connection of power cable, drain pipe etc as per direction of the EIC.
S&F 15.88mm (5/8") & 6.35mm (3/8") copper pipe with keno foam insulation & 8core 2.5Sqmm copper un aurmored cable. [ for connection of indoor unit to out door unit]
Supply & fixing of 20 mm dia PVC pipe for drain out the water from cooling unit.
S&F timer DB for intermittent operation of AC machines. Consisting of following accessories. i) ( L&T, LTSD08N) 8 way SPN DB ii) 240V, 32A DP MCB ( L&T ) iii) 22A TP Power Contactor with 220V coil voltage, ( L&T, Cat No. MNX22-2P, CS90238 ) iv) Digital Time Switch ( L&T, Cat No. Crono 67DDT0 ) v) Wiring with 4 sq mm FR PVC insulated wire, including connector, indicating lamp, and panel locking arrangement with labour
Supply & Fixing of 25 liter capacity Geyser including connceting pipe [make - AO- smite/Racold](Mpdel:HSE-SDS-025) inluding S & F of required size Hot & Cold water host pipe (ISI make) with necessary hook/bolts/fastnuts as required for fixing & installation of Geyser
SUB-HEAD 8-- CC TV
Supply,Installation,Testing & Commissioning of 2 Megapixel IP IR Bullet Camera, 3.6 mm lens,10-20 meters IR distance,12VDC (Make:Hikvision/Honeywell/Pelco/Equivalent)
Supply,Installation,Testing & Commissioning of 2 Megapixel IP IR Dome Camera, 3.6 mm lens,10-20 meters IR distance,12VDC (Make:Hikvision/Honeywell/Pelco/Equivalent)
Supply,Installation,Testing & Commissioning of 32 Port NVR (Make:Hikvision/Honeywell/Pelco/Equivalent)
Supply,Installation,Testing & Commissioning of 24 Port Gigabite Network Switch(Make:D-Link)
Supply,Installation,Testing & Commissioning of 8 Port Gigabite Network Switch(Make:D-Link)
Supply,Installation,Testing & Commissioning of 4TB HDD(Make:Seagate)
Supply,Installation,Testing & Commissioning of 2 Amp 12 volt Power supply(Make:ERD)
Supply,Installation,Testing & Commissioning of RJ45 connector with RJ connector hoods (Make:D-Link)
Supply,Installation,Testing & Commissioning of 4X4 Box
Supply,Installation,Testing & Commissioning of Power Jack
Supply,Installation,Testing & Commissioning of HDMI Cable 1 Mtr.
Supply & Installation of 4U Rack(Make:D-Link)
Supply,Installation,Testing & Commissioning of 32" Full HD LED Display.(Make:Samsung/Sony)
Supply,Installation,Testing & Commissioning of 2 KVA online UPS with 30 mins backup (Make: Numeric/ Powerone/Emerson or as per choice of EIC)
Supply & Laying of CAT6 Cable with 20mm PVC Conduit pipe on the surface of the wall.(Make:D-Link for CAT6)
Supply & Laying of 2C X1.5 Sqmm Cable with 20mm PVC Conduit pipe on the surface of the wall.(Make:Finolex/MEM/Polycab for Cable)
NOTE: 1. Rates should be quoted in words as well as in figures Inclusive of all taxes, duties and delivery charges. 2. If any refurbished material is supplied and installed , Panel action will be will be takena as per existing rules. 3. 12% GST and 1% labour wellfare cess will be deduct from the bill. 4. Price variation clause will not be accepted. 5. Terms of payment:- as per PWD norms. . 6. Conditional offer specially in deviation to the above clauses is liable to cancellation.
S. A. ENTERPRISE
RIK ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .