Loading…
Loading…
| # | Company | Amount |
|---|---|---|
| 1 | ₹34.3 Cr DARBHANGA | DARBHANGA | BIHAR | 846001 |
Tender Value
₹34.3 Cr
EMD Value
₹44.3 L
Closing Date
18 Feb 2026, 3:00 pmClosed
EXECUTIVE ENGINEER BUILDING DIVISION LAKHISARAI
EXECUTIVE ENGINEER
EXECUTIVE ENGINEER BUILDING DIVISION LAKHISARAI
SUPERINTENDING ENGINEER BUILDING CIRCLE MUNGER`
SE
CONSTRUCTION OF BLOCK BUILDING CUM CIRCLE OFFICE CUM RESIDENCE BUILDING AT PIPARIYA DISTRICT- LAKHISARAI
122689
NIT 16/BCD/LKH/25-26
Open Tender
CIVIL
Lakhisarai
• Bid Security Amount in Rupees (A) Unconditional bank guarantee from any scheduled Indian bank issued within the state in the format given. 16.1 Total Bid Security Amount in Rupees Rs. 4432000.00 IFB
• (i) Legal Status of Bidder 4.3(a)
(ii) Place of Registration.
(iii) write Principal place of Business
(iv) Power of attorney of signatory Bid 4.2(iv)
• Total value of civil engineering construction work, in Rupees, Performed in last five years. Minimum annual financial turnover (in all classes of civil engineering construction works only) amount of construction work ,which must be at least equal to 50 % of estimated cost of works for which bid has been invited. The turn over will be indexed at the rate of 8% for a year 4.5(A) (a) 2020-21 2021-22 2022-23 2023-24 2024-25
• Amount in Rupees related to Work Experience of Similar nature Satisfactory completed at least one similar work of value not less than 50% of estimated Cost .5(A) (b)
• (c) Executed in any one year, the minimum quantities /amount of the following items of work (units shall be same as in Requirement column). Items Qty Unit 4.5A( c)
S. NO ITEMS Unit 50%
1 Pile Length M 9443.00
2 Local Sand M3 20640.27
3 P.C.C+R.C.C M3 4228.62
4 Reinforcement Kg 497793.6
5 Tiles M2 4251.00
6 Brick Work M3 1481.465
7 Earth work M3 647.055
8 PHE Work Rs 60,64,920.00
9 Fire fight work Rs 23,21,865.00
10 Furniture Rs 29,64,749.00
11 Electrification Rs 1,56,02,527.00
• (a) Amount of Existing commitments and ongoing works in Rupees Sec 2-1.4(A)
• (b) Amount of Work for which Bid already submitted, in Rupees Sec 2-1.4(B)
• Numbers and Maximum age of Equipment with bidder Type of Equipment Nos. Maxm. Age 5 Year
Concrete Batching & Mixing plant Minimum capacity 15m3/hr . 5 1
Pump for concreting 5 1
Transit Mixture 5 1
Vibrator (Plate & Niddle) 5 5
Water Tanker 5 2
Steel shuttering 5 10000sft
• Name of the Personnel and Experince in years and Select from drop down list Personnel / Qualification 4.5(B) (b)
Project Manager B.E. Civil + 10 Years Exp. (5 years as Manager having MBA) or equivalent or retired E.E. 1 No.
Site Engineer B.E. (Civil) + 03 Years Exp. (3 years in Building Construction) or Diploma in Civil + 7 year Exp. In Building construction or retired A.E. 2No
Plant Engineer B.E. Mech./ Civil + 03 Years Exp. or Dip. Mech + 05 Years Exp. or Retired J.E. 1 No.
Quantity Surveyor B.E. Civil + 03 Years Exp. or Dip. Civil + 05 Years Exp. 1 No.
Site Supervisor Fresh Graduate in Civil or Diploma Civil + 02 Years Exp. or retired I.T.I Holder. 3 Nos.
• Evidence of accesses to Financial Resources in Rupees Evidence of access to or availability of credit facilities (10% of estimated cost), certified by bankers (for work under this bid). 4.2(i)
• Proposed methodology and programmer of construction Select from drop down list the proposed methodology and programmer of construction, backed with equipment planning and deployment 4.3(l)
• Litigation History. Select from drop down list. Information regarding any litigation, current or during the last five years, in which the Bidder is involved, the parties concerned, and disputed amount. (Attached or not) 4.3(j)
• Affidavit Select from drop down list. Regarding statements made in the required attachments are true and correct. Sec-2, Affidavit
• Undertaking Select from drop down list. Able to invest a minimum of cost up to 25% of contract value of work. During implementation of contract. Sec-2, Undertaking
• Registration No. IT.& ST Registration & clearance Certificate Labour License Character Certificate NOC for Debar (If required)
CIVIL
PERCENTAGE
L1
1
22 documents required · 22 mandatory
₹10,000
Processing Fee: 5900
₹44.3 L
AT CE SOUTH BCD PATNA OFFICE, 17-01-2026 03:00 pm
9 Jul 2026
12 Jan 2026
19 Feb 2026
12 Jan 2026
18 Feb 2026
12 Jan 2026
17 Jan 2026
Excavating, supplying and filling of local earth (including royalty but excluding cairriage cost) by mechanical transport upto a lead of 3 km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. If local earth is available at more than 3 km lead the actual lead must be approved by compitent authority. cairraiage of material will be paid seperately and calculated after deducting initial lead.
metre
metre
metre
63 CM (25) UNDER -REAM Making 63 cm (25) dia under ream at required with hand auger of approved quality in ordinary soil (vide classification of soil ifem - A) true to plumb and without eccentri city in my stage of opration and disposal of the excavated earth up to 50 mts lead in eluding all lifts , all complete as per approved design and direction of (E/l)
Add or deduct for providing richer or leaner mixes respectively at all floor levels.
Providing M-30 grade R.C.C. instead of M-25 grade R.C.C.
Single pile upto 50 tonne capacity
per test
per test
Per 50 kg Cement
Metre
Metre
TMT-500- 8mm dia .
TMT-500-10 mm dia.
TMT-500-12 mm dia
TMT-500-16 mm dia.
TMT-500-20 mm dia.
TMT-500-25 mm dia
TMT-500-32 mm dia
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete structural elements, excluding the cost of centring, shuttering finishing and reinforcement, M-20 grde reinforcd cement concrete
All work upto plinth level
Brick work with fly ash bricks as per IS 12894(2002) & IS 3495 in foundations and plinth in :
Cement mortar 1:6 (1 cement: 6 coarse sand ) - 250 mm th Brick work
Half brick Masonary Cement mortar 1.:4 (1 cement: 4 coarse sand ) - 125 mm th Brick work
Brick work with bricks of class designation 100A in foundations and plinth in:
Cement mortar 1:4 (1 Cement :4 coarse sand)
Brick work with bricks of class designation 100A in foundations and plinth in :
Cement mortar 1:6 ( 1 cement: 6 coarse sand)
Half brick masonry with bricks of class designation 100A in foundations and plinth in :
Cement mortar 1:4 ( 1 cement: 4 coarse sand)
Extra tor Brick work in superstructure above plinth level upto floor V cum
Metre
Metre
metre
Metre
Metre
Steel windows
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings, the aluminium quality as per grade 6063 T5 or T6 as per BS 1474, including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-charge. (The item includes cost of fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account)
Designing, fabricating , testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the buildings for all heights and all levels,including
Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.
Providing designation fly ash brick flat soling joints filled with local sand including cost of watering taxes, royalty all complete as per building specification and direction of E/I.
Providing and laying Vitrified in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg / sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with notch towel, piler, wedge, clips of required thickness, leveling sysem and rubber mallet for placing the tiles gently and easily
Glazed Vitrified tiles Matt / Antiskid finish of size
Size ot tile 600 x 600 mm
Metre
metre
1:3 (1 cement:3 coarse sand)
Distempering with 1st quality washable distemper (ready made) of approved manufacture and of required shade and colour complete. As per manufacture's specifications.
Two or more coats on new work
Providing and applying white cement based putty of average thickness 2 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Metre
Finishing walls with Premium Acrylic smooth exterior paint with silicone additives of required shade.
New work (Two or more coats applied @ 1.43 ltr / 10 sqm. Over and including base coat of water proofing cement paint applied @ 2.20 kg / 10 sqm).
1st course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface.
IInd course of 20 mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface.
IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg per sqm of area.
IVth course of 400 micron thick PVC sheet (overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm
Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) > 78, solar reflection > 0.70 and initial emittance > 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner.
Providing plinth protection 750 mm wide consisting of 12 mm thick cement plaster 1;6 with neat cement punning over 75 mm thick P.C.C. (1:3 :6) over brick flat soling over 75 mm thick local sand filling all complete
Providing plain cement concrete in (1:2:4) including making grooves laid in pattern of tiles 300 x 300 mm avg. thickness 40 mm on sloped roof as per drawings all complete.
Metre
Metre
metre
100m (length) x 1 cm (wide) x 1 cm (depth)
meter
Compacting original ground Compacting original ground supporting subgrade (Loosening of the ground upto a level of 500 mm below the subgrade level, watered, graded and compacted in layers to meet requirement of table 300-2 for subgrade construction)
Construction of subgrade and Earthen Shoulder (Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 300-2)
Granular Sub-Base with Graded Material ( Table:- 400- 1) Plant Mix Method (Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401.)
Rate per cum for grading-II Material
Providing and laying factory made chamfered edge Cement Concrete paver blocks of required strength,thickness & size/shape, made by table vibratory method , to attain superior smooth finish using PU or equivalent moulds, laid in required Grey colour & pattern over 50mm thick compacted bed of coarse sand, compacting and proper embedding / laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with jamuna sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand in footpath, parks,lawns, drive ways or light traffic parking etc. all complete as per manufacturer’s specifications & direction of Engineer -in-Charge:
Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete etc. as per direction of Engineer-in-charge (length of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be approved by Engineer-in-charge).
Providing and stacking of Polyalthia longifolia (Ashok) of height 180-195 cm. in gunny bag of size 30 cm as per direction of the officer-in-charge.
Providing and stacking of Delonix regia (Gulmohar) of height 150-165 cm. in big poly bags of size 25 cm as per direction of the officer-in-charge.v
Providing and stacking of Bottle palm of ht. 150-180 cm bottom girth 20-25 cm well developed in big poly bags of size 25 cm as per direction of the officer-in-charge.
Providing and stacking of Cassia biflora of height 90-105 cm., well branched, bushy in big size HDPE bag as per direction of the officer-in-charge.
Providing and stacking of Hamelia patens of height 90-105 cm. bushy in big size HDPE bags as per direction of the officer-in-charge.
Providing and stacking of Mussaenda erythrophylla (Rosea) of height 60- 75 cm. multi branched in earthen pots of size 25 cm as per direction of the officer-in-charge.
Providing pre-cast R.C.C. M-200 slab of desired size with approved quality of clean coarse sand of F.M 2.5 to 3 including curing, shuttering, carrying the slab manually to site and laying in position including the cost of reinforcement, taxes and royalty all complete, as per building specification and direction of E/I.
Providing brick-bat filling in foundation trenches or in plinth in layersnot exceeding 20 mm in depth : Consolidating each deposited layer by ramming and watering for 1 cumt
Supplying G.I. pipes and boring by Jet or Dheki and lowering G.I pipe of requisite dia cutting the pipe and threading them if necessary etc. all complete including providing all tolls and plants required for the job as per specification and direction of E/I .
Providing well burnt brick bats or Jhama bricks including ramming properly till compacted thickness is achieved, curing and carriage of water with all leads, making proper slope and blinding the top with cement mortar (1:10) all complete as per building specification and direction of E/I.
wall / mounted (300 x 420 mm )
wall / mounted (155 x 400 mm )
wall / mounted (155 x 210 mm )
wall / mounted (155 x 155 mm )
wall / mounted (155 x 300 mm )
Ceiling suspended
Bricks (Lead - 1 km kutcha + 7 km pucca)
Coarse Sand (Lead-5 Km) from kuil
Stone Chips (Lead - 170 Km) from Mirza Chowm
Local sand (1 km kutcha + 2 km pucca)
Cement
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
Metre
meter
meter
meter
Metre
Metre
Metre
Metre
metre
Metre
Metre
Metre
Metre
Metre
Metre
metre
metre
Providing 150mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron concrete (1: 4:8), over one brick designation 100-A flat soling in proper grade and slope at the base, the drain duly plastered in CM. (1:3) with punning over exposed surface all complete as per building specification and direction of E/l,
metre
metre
metre
metre
metre
metre
Supply fixing 2 HP Motor Pump (1 Unit) with 32 mm dia clamp (1 Unit), Suitable Length of cable, Panel Board & Starter (1 No.), centre Guide ( 6 Nos.) Machine Up and Down etc. all complete
Proving, Installation, testing and commissioning of Variable frequency drive pumping system 1 set comprising of vertical stainless steel pumps with single VFD, pressure transducers, common frequency invertor which should be transferable from one to other depending on demand of flow and electronic pressure/level switch and interconnecting cables for dry run protection. The pumps shall be automatically sequenced for alternate start. All components shall be mounted on a common structural base frame with suction and delivery headers, gauges, valves and non return valves at suction/delivery, cabling between panel and pumps as per specifications. Hydro booster vessel of approx. 200/100 liters capacity with interchangeable butyl rubber membrane shall be mounted on the system. Vendor to confirm the capacity of tank and pressure rating. Each pump shall confirm to the following specification.:-
(For Domestic Water Supply to all Buildings)
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
100mm dia
80mm dia
65mm dia
50mm dia
100mm dia
80mm dia
65mm dia
50mm dia
100mm dia
80mm dia
65mm dia nominal bore.
80mm dia nominal bore.
100mm dia nominal bore.
40mm dia
50mm dia
50mm nominal bore
65mm nominal bore
80mm nominal bore
100mm nominal bore
20 mm dia
25 mm dia
32 mm dia
40 mm dia
50 mm dia
65 mm dia
80 mm dia
100 mm dia
150 mm dia
Providing, installing, testing & commissioning of Main Electrical Panel -Motor Control Centre fabricated from 16 gauge MS sheet with powder coated finish. The control panels should be comparable with HP of the motor as specified and as per specifications provided.
OUTGOING FEEDERS
DOL PUMP STARTERS
WATER LEVEL INDICATION (In Plumbing Plant Room)
For Domestic Water Tank - 1 set
For Raw Water Tank - 1 set
WATER LEVEL CONTROLLERS ( For Pumps in Control Panel)
Control cable 6 core 1.5 mm2
Control cable 3 core 1.5 mm2
Power cable, Copper conductor, 3 core 2.5 mm2
Power cable, Copper conductor, 3 core 4 mm2
Power cable, Al conductor, 4 core 4 mm2
Power cable, Al conductor, 4 core 6 mm2
Power cable, Al conductor, 4 core 16 mm2
Power cable, Al conductor, 4 core 25 mm2
Metre
Metre
40 mm dia.
32 mm dia.
25 mm dia.
Providing and fixing mineral fibre false ceiling tiles at all heights of size 595X595mm of approved texture, design and pattern. The tiles should have Humidity Resistance (RH) of 99%, Light Reflectance ?85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Fire Performance as per (BS 476 pt - 6 &7)in true horizontal level suspended on interlocking TGrid of hot dipped all round galvanized iron section of 0.33 mm thick (galvanized @120 gsm ) comprising of main T runners of 15x32 mm of length 3000 mm, cross T of size 15x32mm of length 1200 mm and secondary intermediate cross T of size 15x32 mm of length 600 mm to form grid module of size 600x600 mm suspended from ceiling using galvanized mild steel item (galvanised@80gsm) 50 mm long 8mm outer diameter M-6 dash fasteners, 6 mm diameter fully threaded hanger rod up to 1000 mm length and L-shape level adjuster of size 85x25x2 mm, spaced at 1200 mm centre to centre along main ‘T’. The
Providing, fittings & fixing vertical venetian blinds (of vista, mac make) to window made with aluminium slate or approved thickness, colour quality with all accessories including adjuster, hardworks complete with all labour and materials in all floors.Design and colour to be approved first by Engineer-in-Charge.
Providing and fixing anodised aluminium work for doors, windows, ventilator? and partitions with extruded built up standard tubular and otner sections of approved make conforming to IS : 733 and IS : 1285,anodised trasparent or dyed to required shade according to IS : 1868,(Minimum anodic coating of grade AC 15), fixed with.rawl plugs and screws or with fixing clips , or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust fre straight, mitred and jointed mechanically wherever required including cleat angle,.Aluminium snap beading tor glazing/paneling, C.P. brass/stainless steel screws, all complete as per architecttural drawings and the directions of Engineer-in-charge.(Glazing and panelling to be paid for separately.)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Providing & fixing of Aluminium Framed preliminated painted board complete wirth fixing of room no. / name plate / exit route in Hostel rooms & chambers of Institute block and hostel as per choice of client / E/I
Full height storage (size : 1200 L x 1975 H x 600 D) for Record room Making, supply and installation of Wooden Wardrob, 600mm deep, the sides, Top of B.W.P. lesard with 1.0 mm laminates finish. 12 mm thick B.W.P. Ply The front shutter with 19 mm thick B.W.P. Ply wood of century ply or equivalent with 1.0 mm thick. laminates movable roller, channel, recess knob Itallica Locks glass etc. including all fitting & fixture shall be complete in all respect. as per drawing and direction of E/I.
Storage Unit Low Height for Officer chamber (size :1050L x 430W x 750H) Supply , Fabrication and Installation of low height storage unit. The structure of made out of 18mm thick pre-laminated board (PLB). The shelves are made out of 18mm thick (PLB) , which are adjustable in height. The shutters are made out of 18 mm (PLB) openable and fitted by hinges, recessed handles, locking unit and levelers are considered, all complete as per drawing and directly of E/I.
Information Desk : (3775 x 750 x 900 h) Supplying and fixing Information Desk made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Interaction Countre : Size (4200 mm x 750 x 900 H) Supplying and fixing Interaction Countre made of 25 mm thick prelaminated board top with PVC edge binding on wooden frame completes with shelves, key board and CPU Trolley, wire manager with all hardware. Internal wooden surface polished all complete per drawing and direction of E.I.
Side table (size : 510 x 440 x 450mm) Supply,Fabrication & Installation of side table made of prelaminated board top matched with bed finish , with all necessary fixtures and fittings complete as per drawing and direction of E/I.
Canteen Table (size : 900x900) - Supply, Fabrication and installation of rectangular table of size (900 x 900 x 750 H) with preliminated Particle board top over chrome base leg all complete as per drawing design and direction of E/I.
Dining Table - Size : (2000 x 800 x 750 mm H) - Supply Fabrication & Installation of Dining Table top of 19 mm thick PVC laminated board with 2 mm thick PVC edge banding , supported with M.S Rolling sqaure section framed complete with all fittings and assessories as per drawing & direction of E/I.
Meeting Table / Confrence Table - 22 persons Size : (5400 mm x 750mm x 900mm Ht.)
Executive table with return unit –
Sr.officers Table (size : 1350 x 750 x 750 mm)
Works station / Computer table (Size 1050 x 450 x 750mm (H)) Supply of Computer table made of 25 mm thick pre laminated particle board work top the tables will be lipped with PVC edge band of 2.0 mm thickness with frames : 50 mm thick and 1050 Ht , Base 700 mm five pronged base is made out of GF nylon - 6with an embedded metal rings and bottom ribs for additional support and strength lockable drawer unit and CPU stand wire manager at Top complete as per drawing design and direction of E/I.
Supplying, Fitting and Fixing of 3 seater chair (Chrome)
Supplying, Fitting and Fixing of Officer's Chair (Medium back) -
Supplying, Fitting and Fixing of Computer staff / visitor's chair (low back) -
Dining Chair - Supply , Fabrication and installation of dining chair with solid beech wood frame and legs with melamine polish. The seat and back rest shall be fully uphole stered with leatherlite / Fabric finish All complete as per drawing design and direction of E/I.
Dining Chair (Stackable ) for Hall - Plastic Seat & BAck Without Arms and with Powdercoated Legs 'Providing and Fixing Featherlite Make MAGNA Chair The frame is made out of 22mm tube of 16gauge tube Welded by Co2 welding process for uniform surface, Thermo set powder coating epoxy polyester hybrids of harness (pencil) H.B.74 and impact resistant (in lab) 60-160 kgs cm and to a thickness of 40-50 microns is carried out of 7 step pretreatment process. The Back Shell is made out of Talc filled 10% poly propylene co polymer molded with ergonomic see through design
Godrej Reception Table Double Arch with DL Top of size 2410 x 1065 x 725-Worksurface, 1035-Counter, D L Top Top-Clean matt PU finish 18mm thick Inside radius 700.0 Mm Outside radius – 1350.0 mm Depth – 650 mm Glass-Frosted Glass 10mm thick Diamond cut finishing on edges Inside Radius – 1202.5mm Outside radius – 1402.5mm Depth – 200mm, Modesty Panel-MS Perforated sheet Below Worksurface : 0.8 mm (thick) x 665.0 mm (height) x 1345.0 mm (flat length) Above Worksurface : 0.8mm (Thick) x 260 mm (height) x 1345.0 mm (flat length), Legs-MS tube 1.6 mm thick Diameter 50.8 mm Height 604 mm
Cantiliver Chair - Cantiliver Chair Size (W)480mm X (D)440mm X (H)820mm. The Perfect Addition To Our Lineup Of Fabric Upholstered Chairs. The Chair Has Soft Foam Cushions Encased In Blue Fabric That Is Sure To Liven Up Any Workspace. Set On A Sleek Cantilever Base Of Powder Coated Metal, Descent Has Fixed Closed Loop Arms. A Simple Design For Executive Seating Along With Two More Variants Offer More Variety Within The Family. The Product Should be Certified Company BIFMA,ISO-50001,Green Guard, Green PRO, Sedex,AIOTA, IGBC, AGSI,FSC, Indian Design Mark, ISO14001, 18001 & PEFC.
Providing, laying, testing & commissioning of 'C' class heavy duty MS pipe conforming to IS 3589/IS:1239 including Welding, fittings like elbows, tees, flanges,tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required :
Excavating trenches of required width for pipes cables, etc, including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil , and then returning the soil as required , in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc and disposing of surplus excavated soil as directed , within a lead of 50 m
Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS: 5312 complete with rubbergasket, GI bolts, nuts, washers etc.as required :
Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required :
Internal Hydrant System
Supplying and fixing Single headed external yard hydrant valve with 1 No. 63 mm dia instantaneous FM Gunmetal/Stainless Steel coupling and cast iron wheel, ISI marked, conforming to IS 5290 (type A) with blank Gunmetal/Stainless Steel cap and chain as required :
Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket.
Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required : Stainless steel (Grade 304)
Providing and fixing fully glazed MS fully welded construction double leaf door shutter for fire hydrant station fabricated from MS 50x50x6 mm angle iron frame, fixed to wall and hinged MS 40x40x5 mm angle iron door shutter with required MS sash bars for glazing complete with locking arrangements, stove enamelled fire red finish with 'FIRE HYDRANT' written in front. Approximate size 2100x900mm.
Providing and placing in proper position Stainless Steel 63mm dia short size branch pipes with 20 mm dia nozzles with 63mm instantaneous coupling ISI marked (IS:903).
Providing and fixing brass / bronze lever operated ball valve of full flow with stainless steel ball (AISI 304 and spindle AISI 410) with setting and gland of superior quality having minimum working pressure of 20 kg/cm2. 25mm dia
Supply, installation, testing & commissioning of 25mm dia air release valves of approved make on the top of each 150mm dia basement sprinkler ring main as per standard fire practice
Providing and fixing pressure gauges with isolation cocks and chrome plated copper pipes as hydrant station to read pressure from 0-25 kg/cm2 complete and of dial dia 150 mm.
Supplying and fixing of fire brigade connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required : 4 way - 150 mm dia M.S. Pipe
External Hydrant System
Supplying & fixing 63 mm dia gun metal short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipecoupling as required :
Fire Pumps & Accessories
(a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft,mechanical seal conforming to IS 1520. (b) Suitable HP Squirrel cage induction motor, TEFC, synchronous speed 1500 RPM, suitable for operation on 415 volts, 3 phase 50 Hz, AC supply with IP 55 protection for enclosure, horizontal foot mounted type with Class-'F' insulation,conforming to IS-325. (c) M.S. fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. (d) Suitable cement concrete foundation duly plastered with anti vibration pads.
a) Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) b) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. c) SuitableHP squirell cage induction motor TEFC type suitablefor operation on 415 volts, 3 phase 50 Hz AC supply with IP55 class of protection for enclosure, horizontal foot mounted type with Class-'F' insulation, conforming to IS : 325. d) M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. e) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required: (Terrace Pump) (a) Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520 (b) Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-'F' insulation, conforming to IS-325. (c) M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required. (d) Suitable cement concrete foundation duly plastered and with anti vibration pads.
Providing & fixing of pressure switch in M.S. pipe line including connection etc. as required
Providing, fixing, testing and commissiong of motor control centres fabricated from 16 gauges MS sheet with powder coated finish. The control panels should be comparable with H.P. of the motor as specified.
Providing and fixing motor control centres fabricated from 16 gauge M.S. sheet with Powder Coated finish. The control panels should be compatible with H.P. of the motor as under and as per spcifications with automatic star delta starters. (One separate panel to be located in the plant room).
One incoming main isolation MCCB TP of Min. 250 Amps. rating.
Fully taped aluminium bus bar of required capacity in a separate bus bar chamber.
Isolation MCCB for each unit of required rating and with fully automatic starter as per requirement with push button and ON/OFF indicating lights for each unit, for following requirements:
One main fire pump of 50 HP.
One jockey pump of 10 HP (Each).
One Diesel Pump Controlling System
Single phasing preventors of suitable rating one for each motor.
One 96mm square panel type Amp. meter reading 0-500 Amp. for main fire pump and sprinkler pump.
One 96mm square panel type Amp. meter reading 0-500 Amp. for each Jockey pumps.
Appropriate etched plastic plate for each starter/switch.
Colour coded internal wiring from incoming main to bus bar, switch gear, starters, meters indicating lamp etc., complete in all respects.
Providing and fixing heavy duty Aluminum armored cables 1.1 KV grade including necessary support clamps at ceiling level, connection lugs and double compression glands, complete in all respects.
Power cable 3 core 16 Sq.mm
Power cable 3 core 25 Sq.mm
Fire Alarm System
Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required.
Supplying, installation, testing & commissioning of fault isolator complete with base as required.
Supplying, installation, testing & commissioning of addressable manual call point complete as required.
Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required
Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm
Automatic Sprinkler System
Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessories :
Fire Extinguishers
Supply, Installation, Testing & Commissioning of ISI marked (IS:15683) Portable fire extinguisher, of 4.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667 of not more than 0.667and wall suspension bracket.
Supply, Installation, Testing & Commissioning of ISI marked (IS:2878) Portable fire extinguisher, of 22.5 kg capacity Carbon-dioxide type flat base including valve, discharge hose of not less than 10 mm dia 1m long & complete in all respects including initial fill with CO2 gas confirming to IS: 307-1966 filled to a filling ratio of not more than 0.667of not more than 0.667and wall suspension bracket.
SOR&DSR
Wiring for light point/ fan point/ exhaust fan point/ Call bell Point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable size G.I box etc. as required. Group - 'C'
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supply and erection of 6 metre height Hot-dip galvanized octagonal street light pole with following arm with top dia 70 mm and bottom dia A/F 130 mm, made of 3 mm thick sheet along with base plate of size 220 X 220 X 12 mm , small door opening for junction box mounting including 6A 'C' series SP MCB, connector, and suitable size foundation bolts with template as required.(but without pole foundation)
Supplying and connection of following sizes ISI marked FR PVC insulated, single core copper conductor cable etc as reqd.
Fabrication, supply, Installation testing and commissioning of Street Light Feeder Pillar of cubical construction, floor mounted type, fabricated out of 14 SWG CRCA sheet, compartmentalised with hinged doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, digital ammeter & voltmeter, RYB LED lamp, inter-connection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals etc. complete in all respect, suitable for following incoming and Outgoings as required. (CPRI Approved Panel Mfg.)
Supply, Installation, testing & commissioning 200 KVA, 11 K V / 433 V, 50 Hz, 3 phase Delta / Star connected, copper wound ONAN Transformer with Dyn-11 vector group suitable for out-door, floor mounting. The transformer shall have OFF Load taps in steps of +/- 2.5 % and +/-5 %, complete with first fill of oil and shall conform to I S : 2026 - 2011 & IS : 1180 (Level-2) : 2014 (latest edition). H. T. & L. T. sides of the transformer shall be suitable for cable termination box / Busduct Termination box complete with cable end-boxes as follows: Make:-kotsons/Powerstar /kirloskar/crompton HT SIDE: 11 KV ,3C X120MM XLPE CABLE ,LT SIDE:,2 X 3.5 X185 Sq. mm. XLPE CABLE Transformer shall have provided with winding over temperature indication and trip devices.
Supply ,Installation, testing and commissioning of 2 Pole mounted DP providing I no 11kv,400A GOC in accordence with ie rules& local authority specifications and drawing and comprasing the following
Supply, Installation, testing and commissioning of silent type DG set comprising with diesel engine water cooled , synchonous alternator , AMF panel three phase , acoustic enclosure, battery with charger and related accessories, including PCC 1:2:4 platform, incoming cable 10 meter, earthing GI/CU plate 2 nos. including exhaust pipe B class with insulation as per CPCB IV+ norms etc as required. Make:- Kirloskar/ Ashok Leyland/Cummins.
Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required.
Supply & making end termination with brass compression gland & aluminium lugs for following size of FRLS insulated and FRLS sheathed aluminium conductor cable of 1.1KV grade as required.(Including 5.36% GST)
Suuply, Installation, testing and commissioning of a fully enclosed type 100 KVAR capacitor panel, dust vermin and IP 55 protected, fabricated out of 14 guage MS sheet duly DPC coated including interconnections, relays specified as below complete as required.
SITC of 2MP IR Bullet Fixed lens Camera -1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, 0.01 Lux at F1.2, 0 Lux with IR, ICR, ONVIF (PROFILE S), support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Three individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, Edge Anlalytics- Line crossing detection, Intrusion detection, Motion detection, Scene change detection, Video tampering, UL, CE, FCC certified. (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Indoor Dome Fixed lens Camera- 1/2.8"Progressive Scan CMOS, 1920 × 1080 at 25fps, Color: 0.01 Lux at F1.2, ICR, ONVIF, support H.265, H.264, MJPEG, DWDR, 3D Digital Noise Reduction, Tripple individually configurable stream, 12 VDC & PoE, IR range: 40m, IP67, IK10, Edge Anlalytics- Line crossing detection, intrusion detection, Motion detection, video tampering, UL, CE, FCC certified. (Approved Makes: Hikvision/ Honeywell/ Bosch)
SITC of 2MP IR Outdoor PTZ Camera - 1/2.8" Progressive Scan CMOS, 1920 × 1080 at 60fps, 4.8 mm to 153 mm, 32× Optical, 16x digital zoom, Color: 0.005 Lux at F1.6, B/W: 0.001 Lux at F1.6, ICR, ONVIF, support H.265,MJPEG, 120 dB WDR, 3D Digital Noise Reduction, HLC, BLC, Defog, EIS, Tripple individually configurable stream, 24 VAC & Hi PoE, IR range: 150m, Pan: 360° endless, Tilt: From -15° to 90° (auto-flip), Pan Speed - from 0.1°/s to 160°/s, Preset Speed: 240°/s, Tilt Speed- from 0.1°/s to 120°/s, Preset Speed: 200°/s, Presets- 300, Alarm Input-2-ch alarm input, Alarm Output-1-ch alarm output, Audio-1 channel input & output, Support on-board storage up to 256 GB (SD card not included), IP66, IK10, Face Detection, Intrusion Detection, Line Crossing Detection, Region Entrance Detection, Region Exiting Detection, UL, CE, FCC certified. (Hi-PoE injector under Si Scope, if PoE is used)(Vertical Pole Mounting Bracket)) (Approved Makes: Hikvision/ Honeywell/ Bosch) /Equivalent
SITC of 32ch Network Video Recorder - Connect Up to 64 IP Cameras, Dual OS, Up to 12 Megapixels Resolution, Two independent HDMI outputs, one HDMI output of 4K resolution,1 VGA output with output upto 1920 × 1080, Support H.265, MJPEG, Supports N+1 hot spare system,Supports RAID0, RAID1, RAID5, RAID6 and RAID10 ,Supports HDD hot swap, Supports Dual Power-Redundant, Incoming Bandwidth 320 Mbps, 8 SATA Hard Disks, ANR Technology, 8 SATA interfaces for 8 HDDs and capacity of each HDD upto 6TB, 3 × USB at least 1 × USB with 3.0, Alarm I/O 16/4, RS-485, RS-232, 2 RJ-45 10 /100/1000 Mbps self-adaptive Ethernet interface, Multiple network monitoring: Web viewer, CE, FCC, UL certified. (Makes: Hikvision/ Honeywell/ Bosch)
SITC of 6TB Surveillance Hard Disk Custom-built for surveillance applications with Image Perfect firmware for crisp, clear, 24×7 video workloads Maximum 180TB/year workload rating—3× the workload rating of desktop drives—for reliable performance in write-intensive surveillance systems Rotational vibration (RV) sensors help maintain performance in RAID and multi-drive systems (4TB or higher) Up to 10TB of capacity to store up to 10,000 hours of HD video (Approved Makes: Seagate/WD/Toshiba)
SITC of SWITCH PORTS: 16-Port 10/100/1000 + 2 x 1GE copper/SFP combo. Fixed-configuration 1RU x 1/2, half-rack width chassis, 16 x RJ45 10/100/1000 BaseT PoE+ ports 2 x SFP/RJ45 combo ports 2 x SFP ports, 1 x USB port (type A, USB 2.0), 1 x Console port (RS232 RJ45)IEEE 1588v2 capable ports 12, MACsec capable ports 12 Switch capacity 24 Gb/s, PoE power budget 115W, Includes power cord & manuals/software access cards, Includes RJ45 to DB9 adaptor Operating temperature: -10°C to 60°C (14°F to 140°F) Storage temperature -40°C
SITC OF Video Management Software equips users with live video from the camera feed, access control, video intercom, alarms, and data storage. Support upto 120 Camera Streaming. Abundant Modules – Video, access control, attendance, intercom, alarm, E-map, and more.Friendly User Experience and Visual Design – Lightweight, flat UI, and component-based design. Multiple-Languages – 33 languages, including English, Simplified Chinese, Arabic, etc.
SITC OF Server for Video Management Software Form Factor: 1U rack, Processor: 1x Intel® Xeon® processor E-2300 or 1x Intel® Pentium® processor GPU Support: NVIDIA Quadro T1000 PCIe Active GPU, Memory: Up to 128GB in 4x DIMM slots, Drive Bays: Up to 10x 2.5 inch hot-swap SATA/SAS drives or 4x 3.5-inch hot-swap SATA/SAS drives Expansion Slots: Up to 2x PCIe Gen4 x8 slots
SITC OF 43” Professional display rated for 16/7 operation with essential professional functions Screen Size 43, Brightness (cd/m²) 350, Contrast Ratio 1200:1, Dynamic Contrast, Ratio 400,000:1, Response Time (ms) 8.0, Display Resolution, (H x V, pixels) 3840 x 2160, HDR (High Dynamic Range) compatibility yes (HDR10, HLG)
Supply , Installation , Testing and Commissioning of 12U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts. Makes: Poweride/MTS/Rittal/APC/APW
SITC of 6 U network Rack
Supply , Installation , Testing and Commissioning of CAT6 information outlet (I/O) for Data, Voice, Camera & Wi-Fi at user end. Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of loaded 24 port CAT6 jack panel for CAT6 cable termination at rack end.Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of CAT6 patch cord 3 feet for rack side switch to jack panel connectivity. Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of CAT6 patch cord 7 feet for information outlet (I/O) to end user device connectivity.Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of 1, 2 and 4 port face plate white for I/O fixing at user side. Makes: Belden/Siemon/Panduit/Leviton
Supply , Installation , Testing and Commissioning of 22 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Makes: Netrack/MTS/Rittal/APC/APW
Supply , Installation , Testing and Commissioning of 9 U (600W/1000D) floor mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Makes: Poweride/MTS/Rittal/APC/APW
Supply , Installation , Testing and Commissioning of Core Switch Port Density - 14 X 1/10G SFP Ports and 12 X 1/10G Base T 2 x 40/100 G QSFP28 Ports. Power Supply - Redundant Hot Swappable Power Supply - AC/DC, Virtual Chassis/ Stacking Option - Upto 6 Switches or more, RAM - 8 GB or better, Flash and Buffer - 32GB or better and 32MB Packet Buffer Switching Capacity and forwarding Rate, 900 Gbps or better and 650 Mpps or better , Latency & MTBF Latency: <650 ns MTBF: 384,636 h,MAC Address 64K, Routes IPv4 - 12k or better, IPv6 - 12k or better. Support for Egress rate limiting, Eight egress queues per port, IEEE 802.1Q, 802.3x, DiffServ, Jumbo frame. Protocol Support - IGMP Snooping V1, V2, V3, MLD, PIM-SM/PIM-SSM/PIM-DM/PIM-Bidirectional, DVMRP,RIPv1v2,RIPing ,OSPFv3, RIP, BGPv4, MP-BGP,GRE, IS-IS, ITU-T G.8032, IEEE 802.1s, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP), Ipv4/Ipv6, DHCP Option 82, BPDU, STP Root Guard, SIP detection, SPB-M or MPLS, IEEE 802.1ae, MIB, NTP,Built-in CPU protection against malicious attacks,The Switch Should have 1+N redundant supervisor manager in Virtual chassis with In-Service Software Upgrade (ISSU), VXLAN, ARP Poisioning detection, Policy based routing (PBR),SDN support through Restful API and openflow 1.3.1, Management SNMP V1,V2,V3, Web GUI, CLI, USB or equivalent memory card, IPv6 management feature on open standards, IEEE802.1ag, TDM or equivalent standards
Security Should support Access Control Lists (ACLs), DHCP snooping, IEEE802.1x based port authentication, RADIUS/ TACACS+, SSL, SSH, port mirroring,NTP, IEEE 1588, AES, Syslog, MD5, LLDP-MED, BPDU Blocking, BFD, Unified management, control and fabric-mesh virtual chassis technology, Autosensing IEEE 802.1X multi- client, multi-VLAN support for bridging and SPBM/VXLAN services,MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks Resiliency IEEE802.1q, IEEE802.1d, IEEE802.1s, IEEE802.1w, ITU-T G.8032 ring resilience/ring protection, VRRPv2, Operating Temperature and Humditiy Temperature: 0 to 45Deg Humidity: 5% to 95% (non-condensing) Safety Certifications CE, EN 55022, RoHS, US UL 60950, CSA22.2 , FIPS 140-2, EAL2 & NCPP Certified , EN 60825-1/2 Laser SFP , SFP should be of same make as switch. Vendor to be present in Gartner Magic Quadrant. The Switch shall work with on-premise and cloud based NMS without change in hardware/software/OS Image. The Switch should be EAL2/NDPP certified Cisco/Juniper / Alcatel-Lucent
Supply , Installation , Testing and Commissioning of Access switch Port Density 24 X 1G RJ-45 Ports 2 x 1G/10G SFP+ Ports and 2 x 1G SFP/Base-T Combo Ports Power Supply Internal Power Supply Virtual Chassis/ Stacking Option Upto 4 Switches or more RAM 1 GB or better Flash 1 GB or better Switching Capacity and forwarding Rate 92 Gbps or better and 68 Mpps or better Latency & MTBF Latency: < 4 µs MTBF: 2595 k hours Layer 2 Features Mac Address:16K or more VLAN: 4K or more System Policies: 1.5K or more Max Jumbo Frame: 9216 bytes Multicast Group: up to 1000 Quality of Service Auto QoS for switch management traffic,Policy-based QoS, Traffic Prioritization, Priority Queues: Eight hardware-based queues per port, SPQ, WRR
Protocol Support Static Routing, MSTP, RSTP, PVST+,IPv6 Tunneling, LACP, LAG, IGMPv3, DHCP, DHCP82,DHCP Relay for IPv4/IPv6,Multiple microcode image support with fallback recovery, ARP,SDN support through Restful API and openflow 1.3.1 Management Loopback IP address support for management per service, Policy- and port-based mirroring, Remote port mirroring, sFlow v5 and Remote Monitoring (RMON), Unidirectional Link Detection (UDLD),Digital Diagnostic Monitoring (DDM), LLDP-MED, NTP,MVRP, SNMP, sflow or equivalent Security Dynamic change of authentication (CoA),MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks, Web based Authentication, Autosensing IEEE 802.1X multi-client, multi-VLAN support,RFC 1321 MD5, RFC 2284 PPP EAP,RFC 1826/1827/4303/4305 Encapsulating Payload (ESP) and crypto algorithms, RFC 2104 HMAC Message Authentication, Built-in CPU protection against malicious attacks Resiliency Unified management, control and virtual chassis technology, Virtual Chassis 1+N redundant supervisor manager, Virtual Chassis In-Service Software Upgrade (ISSU),Smart continuous switching technology, IEEE 802.3ad/802.1AX Link Aggregation Cisco/Juniper / Alcatel-Lucent
SITC of 24 Port POE Network Switch Port Density - 24 X 1G RJ-45 PoE+ Ports with 380W power budget, 2 x 1G/10G SFP+ Ports and 2 x 1G SFP/Base-T Combo Ports upgradable to 2 x 10G SFP+ Ports Power Supply - Internal Power Supply, Virtual Chassis/ Stacking Option- Upto 4 Switches or more RAM - 1 GB or better, Flash - 1 GB or better Switching Capacity and forwarding Rate - 128 Gbps or better and 190 Mpps or better Latency & MTBF - Latency: < 4 µs MTBF: 1447 k hours Layer 2 Features - Mac Address:16K or more VLAN: 4K or more, System Policies: 1.5K or more Max Jumbo Frame: 9216 bytes, Multicast Group: up to 1000 Quality of Service - Auto QoS for switch management traffic,Policy-based QoS, Traffic Prioritization, Priority Queues: Eight hardware-based- queues per port, SPQ, WRR Protocol Support - Static Routing, MSTP, RSTP, PVST+,IPv6 Tunneling, LACP, LAG, IGMPv3, DHCP, DHCP82,DHCP Relay for IPv4/IPv6,Multiple microcode image support with fallback recovery, ARP,SDN support through Restful API and openflow 1.3.1, Management - Loopback IP address support for management per service, Policy- and port-based mirroring, Remote port mirroring, sFlow v5 and Remote Monitoring (RMON), Unidirectional Link Detection (UDLD),Digital Diagnostic Monitoring (DDM), LLDP-MED, NTP,MVRP, SNMP, sflow or equivalent
Security - Dynamic change of authentication (CoA),MAC-based authentication for non-IEEE 802.1X hosts, MAC address lockdown, Prevention from ARP attacks, Web based Authentication, Autosensing IEEE 802.1X multi-client, multi-VLAN support,RFC 1321 MD5, RFC 2284 PPP EAP,RFC 1826/1827/4303/4305 Encapsulating Payload (ESP) and crypto algorithms, RFC 2104 HMAC Message Authentication, Built-in CPU protection against malicious attacks Resiliency - Unified management, control and virtual chassis technology, Virtual Chassis 1+N redundant supervisor manager, Virtual Chassis In-Service Software Upgrade (ISSU),Smart continuous switching technology, IEEE 802.3ad/802.1AX Link Aggregation Control Protocol (LACP) and static LAG groups across modules Operating Temperature and Humditiy - Temperature: 0 to 45Deg Humidity: 5% to 95% (non-condensing) Safety Certifications - CE, EN 55022, RoHS, WEEE US UL 60950, CSA22.2, FIPS 140-2, EN 60825-1/2 Laser, IEC 62368-1 SFP - SFP should be of same make as switch. Vendor to be present in Gartner Magic Quadrant. The Switch shall work with on-premise and cloud based NMS without change in hardware/software/OS Image. Cisco/Juniper / Alcatel-Lucent
SITC of WIFI Access Point Proposed solution will be Controller less/HW Controller based/SW Controller based but all the Access Points managed centralized . The WLAN solution shall propose an indoor 802.11ax Wifi 6 MU-MIMO indoor dual radio AP Access Point (2.4, 5G) AP to support 2x2:2 on 5 Ghz and 2X2:2 on 2.4 Ghz. Access Point shall offer up to 1200 Mbps throughput on the 5Ghz band (low and high bands) and up to 573 Mbps throughput on the 2.4GHz band. 2 x 10/100/1000Base-T autosensing (RJ-45) port . Both ports should support 802.3at PoE,1x USB 2.0 Type C AP should support ACL, wIPS/wIDS and DPI application, 802.11i, 802.1x Access Point shall propose a Factory reset button. Access Point shall support up to 16 SSIDs (8 per radio) with 512 Clients and should support BLE 5.1/Zigbee Integrated. Single AP can act in dual mode (WLC/Client Serving) with controller to support 256 Access Points in single cluster. Distributed Radio Management, Radio Dynamic Adjustment (RDA), Transmit Power Control @ 18 dBM(TPC), DFS, VHT20,40,80 It should support Advanced Cellular Coexistence (ACC) i.e Minimizes interference from 3G/4G cellular networks, distributed antenna systems, and commercial small cell/femtocell equipment L2 Roaming 802.11r Roaming, 802.11K, 802.11v
Operating temperature must be 0°C to 45°C Humidity must be 10% to 90% non-condensing. WFA, UL2043 Plenum rating, EMI,RoHS, REACH, WEEE
Supplying and drawing 2 pair, 0.5 sqmm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed PVC conduit as required.
Supplying and drawing 4 pair, 0.5 sqmm FR PVC insulated copper conductor, unarmoured telephone cable in the existing surface / recessed PVC conduit as required.
Supply, installation, testing & commissioning of termination box for 50 pair EPABX system complete as required
SITC of Communication appliance for Voice,configured for:- 01 PRI- 08 Trunk- 40 Digital- 150 Analog Extensions Internal CLI on Digital Phones and Analog CLI Phones Alcatel-Lucent/Matrix/Cisco
SITC of Ananlog Phone Display type 1 line-Dot-matrix + 1 line 7-segments+ 1 line icons alphanumeric displayDate and time displayed in standby mode Call duration display Number of ringtones 1Ringtones volume levels 3 (high / low / off Handsfree function Handsfree volume control 3, Direct access memories 82-touch memories 10,Caller Identification type I & IIIncoming call log, Mute key Wall-mountable, Dialing type Tone / Pulse Protocol FSK & DTMF, Removable line connector cord RJ11/RJ11, Power supply No battery required Alcatel-Lucent/Matrix/Cisco
SITC of Console Phone Optimised access to all ALE communications features Touch screen or large display with LED buttons 3D Symphonic HD super wideband sound Cylindrical sound bar with 3D diffusion and up to 3 microphones Elegant metal and textile casing with 4 interchangeable colours Extensive connectivity: USB, WLAN, Bluetooth, IP, hybrid digital/IP Secure remote working: VPN, SRTP Accessories include: Alphabetic keypad, wireless handset, WLAN and Bluetooth module, colour display key module Centralised management and deployment from the cloud
Supplying, installing, testing and commissioning of the following as per specification complete with junction box, as and where required.without JB Analogue addressable Photo Electric type Smoke Detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens
Analogue addressable rate of rise cum fixed temperature thermistor type heat detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens
Addressable type Manual Call Point complete as required. Make - Agni/Bosch/Siemens
Addressable Hooter cum strobe complete as required. Make - Agni/Bosch/Siemens
Addressable strobe complete as required. Make - Agni/Bosch/Siemens
Duct casting unit with casing of fabricated aluminium/poly carbonate and hinged inspection cover, 1 No. inlet of proper length & 1 no. outlet tube & with 1 no. analogue addressable photoelectric type Smoke detector with mounting base, address switch complete as required. Make - Agni/Bosch/Siemens
Analogue addressable Fault Isolators for isolating shorted, de-wired and loose circuits between two successive Fault isolators with automatic resetting arrangement. (max. 20 devices for one fault isolators). Make - Agni/Bosch/Siemens
Analogue addressable, automatic commandable Control Switches for switching on/off various ventilation fans, pressurisation fans, zones of speakers etc. and other Fire operation related devices and complete as required. Make - Agni/Bosch/Siemens
Addressable Input Card/monitor module for connecting to Flow Switch etc. Make - Agni/Bosch/Siemens
Response indicator consisting of 16 gauge MS box with 75 x 75 x 6 thick cross brushed MS face plate. Make - Agni/Bosch/Siemens
Zone address module to connect conventional zones with the addressable panel. Make - Agni/Bosch/Siemens
Each loop of fire alarm panel shall have 10 to 15% spare addressable units. At all panels global access to be provided. Information of all the panel shall be accessible from any of panels through networking. All panels shall be upgradable to minimum 25% more loops. Other requirements are given in the specifications. The no. of loops may be changed based on the loop capacity of the panel. loop card.
Providing, installing, testing and commissioning of Zero Loop Repeater Panel for Fire Alarm System with piezo sounder, LCD alpha numeric character display with accept/reset buttons for alarm address of any sensor/field device. The Repeater Panel shall provide field device address as required. The Repeater Panel shall be active & all the setting for fire alarm system can be configured with panel.
Wall mounted speaker with three tap changers in acoustically treated box with speaker and line matching transformer (2W max).(For car park & double height areas)
Ceiling mounted baffle speaker with three tap changers (2W).
Portable UL listed fire phone handsets in a suitable enclosure.
Addressable fire phone jack plates with control/monitor module.
Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specification as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- (a) Solar Photovoltaic Module conversion efficiency shall not be less than 16.5% PV modules used in solar power plants/systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. (b) Connections and interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kv grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories complete job etc. as required. (Including 5.36% GST) Make-Tata Power/Adani/Vikram solar/Waaree
SITC of 30 KVA, 3 Ph, IGBT Based Inverter & Rectifier Both Side True Online Double Conversion UPS and M.S Powder Coated Rack & Interconnecting cable with inbuilt Phase Sequence Correction. For 30 Minutes Battery Backup using 12 Volt 65 Ah, SMF Batteries (Total 24960 VAH for 30 minutes Battery Backup). Make:- Numeric/APC/Vertiv.
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Meter
Meter
Meter
Meter
Meter
Meter
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
Meter
Meter
Supplying and fixing modular Telephone socket outlet on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface / recessed PVC concuit as required.
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Supply and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
SITC of 5.0 LB Novec 1230/FK-5-1-12
SITC lienear pneumatic heat Detection.
SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire).
Meter
Meter
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supply of following sizes and core PVC/XLPE insulated, PVC sheathed (heavy duty) armoured electrical power cable with aluminium conductor for working voltage upto 1.1 KV as required.
meter
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Metre
Metre
Metre
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Meter
Meter
Meter
Meter
Meter
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed PVC conduit as required.
meter
Meter
Supplying and drawing 2 pair 0.5 sq mm. FR PVC insulated annealed copper conductor unarmoured telephone cable in the existing surface / recessed PVC concuit as required.
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus - bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
SITC of 5.0 LB Novec 1230/FK-5-1-12
SITC lienear pneumatic heat Detection.
SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire).
Meter
Meter
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supply of following sizes and core of PVC/XLPE insulated PVC sheathed heavy duty , aluminium conductor armoured under ground cable of graded 1.1 KV for working voltage upto 1100 volts conforming to ISI .
Metre
Metre
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Metre
Metre
Metre
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Meter
Meter
Meter
Meter
Meter
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Meter
Meter
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
Supplying Installing Testing and commissioning of 20 Pair distribution tag box all complete as per specification and direction of E/I
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
SITC of 5.0 LB Novec 1230/FK-5-1-12
SITC lienear pneumatic heat Detection.
SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire).
Meter
Meter
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
Metre
Metre
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Metre
Metre
Metre
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Point
Meter
Meter
Meter
Meter
Meter
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Meter
Meter
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
SITC of 5.0 LB Novec 1230/FK-5-1-12
SITC lienear pneumatic heat Detection.
SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire).
Meter
Meter
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
Metre
Metre
Metre
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Metre
Metre
Metre
Wiring for light point / fan point / exhaust fan point / call bell point with 1.5 Sq.mm FR PVC insulated copper conductor cable in recessed PVC conduit with modular switch modular plate suitable GI box earthing the point with 1.5 sq mm FR PVC insulated copper conductor single core cable etc as required.
Point
Meter
Meter
Meter
Meter
Meter
Supplying and fixing modular T.V antenna socket on the existing modular plate and metal box including making connection but excluding modular plate etc. as required.
Meter
Supplying and fixing following size / modules, GI box along with modular base & cover plate for modular fitting in recess etc. as required. (For TV & Telephone out let)
Supplying & fixing of the 10 pair Krone Type Sub distribution frame box including connection testing etc as required.
Supplying and installation of 10 pair 0.5 sq mm.ATC unarmoured PVC insulated copper conductor telephone cable through existing PVC conduit including connection, testing etc. as required.
Supplying and fixing of following rating C series MCB suitable for inductive and other loads of following poles in the existing MCB DB complete witth connections ,testing and commissioning etc. as required .
Supplying and fixing following rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
50 mm X 5 mm copper strip (2.30 Kg/mtr)
Suppy and fixing panel mounted digital multimeter (Voltmeter & ammeter) including CT coil and RYB pilot indictor in the existing cubical panel board including drilling holes in the panel board making connections etc. as required.
SITC of 5.0 LB Novec 1230/FK-5-1-12
SITC lienear pneumatic heat Detection.
SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire).
Meter
Meter
Supply and installation of regular/standard model A.C. ceiling fan of 1200 mm sweep with service value (CM/MM) minimum 4.00, Air delivery minimum 210 cum/min including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated copper conductor etc as required.
Supply and Installation of following sweep / sizes metallic biade, heavy duty, single phase, 230 V A.C. Exhaust Fan in existing opening including making good the damage, connection, testing and commissioning etc. as required.
Supplying and fixing 2 pin 5 Amp ceiling rose on the existing junction box/ PVC box including connection etc as required.
Supplying and fixing 4'X18 watt LED batten with minimum efficacy 100 lm/w in polycarbonate housing and complete with integrated electronic driver etc directly on wall/ ceiling including connections with 1.5 sq.mm FRLS PVC insulated copper conductor etc. as required.
Supplying fitting fixing of call bell suitable for DC/AC single phase 230 volts,complete etc as required.
Metre
Jointing copper/ G.I. tape ( with another copper/ G I tape, base of the finial or any other metallic object ) by riverting/ nut bolting sweating and soldering etc. as required.
Metre
Metre
Metre
meter
meter
50 mm X 5 mm copper strip (2.30 Kg/mtr)
SITC of 5.0 LB Novec 1230/FK-5-1-12
SITC lienear pneumatic heat Detection.
SITC of Master control unit for controlling each system, complete with pressure switches, buzzers and electronic hooter, including all necessary accessories + electrical wiring to make entire system functional (Make :- Fireterx/tracefire/Safefire).
Rubber mat of 16 mm thik and 1000mm wide to with stand 15kv dielectric strength as per is 5424.1969
Shock treatment chart in English and local language duly framed with glass.
First aid box complete with all standard first aid materials.
Rubber gloves 11 KV grade as per IS 4770-68
Meter
Meter
aoc.json
Purchase Order
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Check list farwarding.pdf
NIT • 1.76 MB
Letter no 7292 E-in- C bcd.pdf
NIT • 0.64 MB
Letter No 3183 Dated 3-6-2020.pdf
NIT • 1.08 MB
Letter no 7291 E-in-C bcd.pdf
NIT • 0.55 MB
FW & E NIT 16 Pipariya.pdf
NIT • 1.45 MB
Civil phe BOQ Pipariya Block dept final (1).xls
NIT • 0.78 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .