| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.0 LAccepted-AOC SHIV NIWAS DHANDA P O TOTU DISTT SHIMLA HP 171011 | SHIMLA | SHIMLA | HIMACHAL PRADESH | 171011 | L1 | Accepted-AOC Being lowest tender | |
| 2 | L2₹10.6 L+₹72,520 (7.34%)Rejected-Finance | L2 | Rejected-Finance Not being lowest tender | |
| 3 | L3₹12.2 L+₹2.3 L (23.7%)Rejected-Finance 01 TIWARI BAZAAR GONDA ROAD TIWARI BAZAAR GONDA UTTAR PRADESH 271001 | GONDA | UTTAR PRADESH | 271001 | L3 | Rejected-Finance Not being lowest tender | |
| 4 | L4₹13.7 L+₹3.8 L (38.2%)Rejected-Finance 227 NEW GANESH VIHAR ADARSH MILL ROAD GHOSIPURA LASHKAR GWALIOR 474012 M P | GWALIOR | MADHYA PRADESH | 474012 | L4 | Rejected-Finance Not being lowest tender | |
| 5 | L5₹15.1 L+₹5.2 L (52.7%)Rejected-Finance 244 SHARDA VIHAR NEAR NEW HIGH COURT GWALIOR 474002 MP | GWALIOR | GWALIOR | MP | 474002 | L5 | Rejected-Finance Not being lowest tender |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Jul 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) ADM AREA
GE (AF) ADM AREA GWALIOR-474020
REPAIR/MAINTENANCE OF GEYSERS AND CONNECTED WORKS IN DOMESTIC AREA AT AF STATION GWALIOR
2023_MES_603250_1
8320/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
GE (AF) ADM AREA GWALIOR
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) ADM AREA
₹40,000
Yes
23 Sept 2023
14 Jun 2023
20 Jul 2023
14 Jun 2023
12 Jul 2023
28 Jun 2023
Amount
Disconnecting & taking down the existing geyser of any description and any capacity (25/35/50 Ltrs) any make and in any position from the existing location for necessary repairs & maintenance/replacement/painting etc complete all as directed
Dismantling, opening of the geyser of 25 ltrs capacity and of any description, material and labour for cleaning and de-scaling the inner tank and other parts/accessories including inlet, outlet, overflow, geyser element, thermostat, U assembly etc. with brush & cleaning rods and using and circulating concentrated de-scaling solution (ORISCALE BLASTER) mixed with water in suitable proportion till the complete deposits/scale is removed and with entire satisfaction of the Engineer-in-Charge, brazing for stopping the leakage of copper inner tank/ gas welding for stopping the leakage of inner steel tanks , fixing the serviceable parts in position, replacing the unserviceable parts, setting insulation properly as required, reassembling the complete geyser after cleaning, repairing and painting. Re-fixing & installation of the geyser in existing position and its testing to the entire satisfaction of Engineer-in-Charge.
Note for Item No 2.00 :- (i) Chemical HCL of make as approved by GE shall be used for De-scaling. (ii) Quoted rate of the contractor includes for fixing the serviceable parts in position and replacement of unserviceable parts with new parts. The new parts shall be measured and paid under respective item of BOQ as supply only” (iii) Painting of Geysers shall be on requirement basis and shall be measured and paid for separately under appropriate item of Schedule `A' iv) Old disturbed insulation shall be made good by the contractor with using old retrieved glass wool. Additional quantity of glass wool for insulation, if any required, other than the quantity of glass wool retrieved from dismantling of geyser, shall be measured and paid for separately
All as per item No 2.00 here-in-before but for Geysers of 50 Ltrs capacity
Supply only the following new parts suitable for Geysers of capacity under BOQ item No 02 & 03 here-in-before:- Note :- (i) The new parts shall be suitable to match with the existing geysers (ii) Fixing element of these items is deemed to be included under the rates quoted by the contractor for respective BOQ item No 2.00 and 3.00 here-in-before.
(a) Inner steel tank for 25 Ltrs capacity having wall thickness not less than 1mm
(b) Inner steel tank for 50 Ltrs capacity having wall thickness not less than 1mm
(c) MS outer cover of any size and shape, for geyser of cap 25 Ltr not less than 1 mm thick all as specified
(d) MS outer cover of any size and shape, for geyser of cap 50 Ltr not less than 1 mm thick all as specified
(e) `U’ assembly for 25/50 Ltrs capacity geyser, with rubber gasket
(f) Geyser elements of 1500 watts, 230 volts capacity Make : Racold/Dasspass/Theeta
(g) Geyser elements of 2000 watts,230 volts capacity Make : Racold/Dasspass/Theeta
(h) Thermostat with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply. Make : Racold/Dasspass/Theeta
(j) Indication lamp of size/shape as approved for geyser of any capacity.
(k) Fusible plug /safety valve as per sample(s) kept in GE office.
(l) Glass wool for insulation Geysers all as approved.
Disconnecting & taking up or down existing unserviceable PVC connections of any description from geysers installed at site and supplying and fixing new PVC connections with nylon braided, 15 mm bore 450 mm long having brass nuts and washers on both ends suitable for hot / cold water complete all as specified & directed.
Disconnecting & taking up or down existing unserviceable PVC connections of any description from geysers installed at site and supplying and fixing new HD PVC connections, 15 mm bore 450 mm long high pressure nylone braided having brass nuts and washers on both ends suitable for hot / cold water complete all as specified & directed.
M & L for painting of existing Geysers of any description and in any position 25/50 ltrs capacity, with applying one coat of Ducco paint (White) by spray machine including preparation of existing decorated surfaces of geysers including writing MES No. of geysers in capital letters of height not less than 20 mm on geysers body in the pattern and style all as specified and directed. Make of Paint:- Asian/Berger/Nerolac
S & F for MS bottom cover of any size and shape, for geyser of cap 25/ 50 Ltr made out of MS sheet not less than 1 mm thick and as per existing size and shape complete all as specified.
Disconnecting, dismantling & taking up or down existing unserviceable `U’ assembly of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new `U’ assembly to match with the existing system complete all as specified & directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt, 230 volts to match with the existing system complete all as specified & directed by Engineer-in-Charge. Make : Racold/Dasspass/Theeta
Description all as per item No 10.00 here-in-before but supply and fixing new geyser element of 2000 watt.
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new thermostat with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed. Make : Racold/Dasspass/Theeta
Disconnecting, dismantling & taking up or down existing unserviceable geyser indication lamp of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new indication lamp complete all as specified & directed.
Disconnecting & taking up or down existing unserviceable fusible plug/safety valve of any description from geysers installed at site and supplying and fixing new fusible plug / safety valve of shape and size to match with the existing system all as specified & directed.
Disconnecting & taking up or down existing unserviceable copper conductor flexible cable of any size & any description and supplying, fixing, connecting & testing new 3 core copper conductor flexible cable of 50/.025 mm size, PVC insulated and PVC sheathed suitable for 1100 volts grade complete all as specified & directed.
Disconnecting and taking out existing defective/ unserviceable complete industrial type socket with top in sheet metal box, of any description & in any position and Supplying and fixing new industrial type socket, 2 pole + earth 20 Amps, with and including plug top and MCB, 20 Amps, ‘C’ series, single pole in sheet metal enclosure all as specified and directed. Make : Legrand /L&T/ABB.
M&L for cutting out holes in existing cement concrete / brick walls built in cement mortar and removing unserviceable/loose/ broken geyser’s mounting bolts including supplying, fixing & grouting new mild steel bolts with screwed end 8 mm dia & 100 mm long along with one washers and one hexagonal nut at screwed end for mounting the geyser on wall using cement mortar 1:3 and making good the disturbed surfaces to match with the existing surface & finishes complete all as directed.
Disconnecting & taking up or down existing unserviceable submain wiring of any description, any size from existing conduit complete all as directed. NOTE: Two run of single core PVC cable with one run of earth conductor shall be measured as one unit.
M & L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4 Sqmm of voltage rating upto and including 1100 Volts drawn in existing conduit with & including one run of PVC (green colour) insulated , unsheathed, stranded copper conductor cable FR of size 4 Sqmm as earth continuity conductor all as specified and directed. NOTE: Two run of single core PVC cable with one run of earth conductor shall be measured as one unit
M&L for sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4 Sqmm of voltage rating upto and including 1100 Volts in and including PVC rigid concealed conduit of dia not less than 20mm with and including one run of PVC (green colour) insulated, unsheathed, stranded copper conductor cable FR of size 4 Sqmm as earth continuity conductor all as specified and directed. [NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit. NOTE : (i) The quoted rates shall be deemed to be inclusive for cutting chases in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with the existing colour of surface.
M&L for sub main wiring in surface conduit using two single core PVC insulated, unsheathed stranded copper conductor cable FR of size 4 Sqmm of voltage rating upto and including 1100 Volts in and including PVC Surface igid conduit of dia not less than 20mm with and including one run of PVC (green colour) insulated, unsheathed, stranded copper conductor FR of size 4 Sqmm as earth continuity conductor all as specified and directed. NOTE: (i) Two run of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Taking down existing unserviceable brass stop valve of any description and any position and supplying and fixing new stop valve, cast copper alloy, CP, fancy type 15mm bore, ISI marked, screwed down high pressure, with crutch or butter fly handle and fixed complete all as specified & directed.
Taking down existing unserviceable brass bib taps of any description and any position and supplying and fixing new bib taps, cast copper alloy, CP, fancy type 15mm bore, ISI marked, screwed down, with crutch or butter fly handle and fixed complete all as specified & directed.
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from 50 Ltrs capacity geyser installed at site and supply and fixing new geyser element of 2000 Watt square flanged type, 230 volts to match with the existing system complete all as specified. (Make:- Recold cat No 65160946 or equivalent make :-Dasspass/Theeta as approved by GE).
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from 50 Ltrs capacity geyser installed at site and supply and fixing new thermostat two in one with cut off facilities and 11” long in size, 230 volts to match with the existing system.. Complete all as specified. (Make:- Recold cat No 3412044 , Dasspass/Theeta or equivalent make as approved by GE)
S&F in repairs for switch socket combination multi purpose, 5 Pin 6/16 amps, flush type With Indicator complete all as specified.
M & L for Plug Top 16 Amps, 240 Volts three pin complete all as specified.
Disconnecting old unserviceable GI Pipe of any description and supply and fixing/laying pipe GI medium grade 15mm bore including fittings fix on wall or laid under floor complete with all accessories ISI Marked complete all as specified and directed.
Dismantling, Disconnecting & taking up or down unserviceable geyser capacity 25 Ltrs of Make Racold of any description and in any position, taking out old unserviceable MS inner tank and supply and fixing new MS Inner tank capacity 25 Ltrs make Racold complete all as specified and directed.
All as per item No 29.00 here in before but Inner tank capacity 50 Ltrs complete.
Dismantling, Disconnecting & taking up or down unserviceable geyser capacity 25 Ltrs Make Racold fixed in any position, taking out old u/s plastic front cover CVRER-25 (V) and supply and fixing new plastic front CVRER-25 (V) capacity 25 Ltrs make Racold complete all as specified and directed.
All as per item No 31.00 here in before but Plastic front cover CVR-50 capacity 50 Ltrs complete all as directed.
Dismantling, Disconnecting & taking up or down unserviceable geyser capacity 25 Ltrs of Make Racold fixed in any position, taking out old u/s plastic outer AL2 WH-25 (V) and supply and fixing new plastic front CVRER-25 (V) capacity 25 Ltrs make Racold complete all as specified and directed.
All as per item No 33.00 here in before but Plastic outer AL-50 (V) capacity 50 Ltrs complete all as directed.
Disconnecting and taking up or down existing unserviceable MCB of any description and in any position complete all as directed.
Supplying & fixing MCB single pole (`C’ series ) 6 to 32 Amps capacity suitable for 240 volts having current rating 10 KA complete all as specified and directed.
Disconnecting old unserviceable metal clad plug top & supply and fix metal clad plug top AP-20 2 pin earth. Complete all as directed. Make : Schneider or equivalent in make ABB/Lelgrand
Disconnecting old unserviceable metal clad plug socket and supply and fix metal clad plug socket top AP 20 2 pin earth complete all as directed. Make : Schneider or equivalent in make ABB/Lelgrand
Disconnecting old unserviceable Heating elements and supply and fix Heating element for instant geysrs of any type and description capacity 3 KW complete all as specified and directed. Make : Das pass cat NO 63401 HC 30CP or equivalent of Make Havells /Surya
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt of Racold Altro-2SP 25V, 230 volts to match with the existing system complete all as specified and directed. Make : Racold /Bajaj /Usha
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt /2000 watt of 9 Hole 230 volts to match with the existing system complete all as specified and directed. Make : Racold /Bajaj /Usha/Jaquar
Disconnecting, dismantling & taking up or down existing unserviceable geyser element of any description and in any position from geyser of 25 Ltrs /50 Ltrs capacity installed at site and supply and fixing new geyser element of 1500 Watt /2000 watt of 6 Hole 230 volts to match with the existing system complete all as specified and directed. Make : Racold /Bajaj /Usha/Jaquar
Disconnecting, dismantling & taking up or down existing unserviceable geyser thermostat of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new thermostat of Racold Altro-2SP 25V/50V with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed by Engineer-in-Charge. Make : Racold/Dasspass/Theeta
Disconnecting, dismantling & taking up or down existing unserviceable geyser Auto Switch of any description and in any position from geyser of 25 Ltrs/50 Ltrs capacity installed at site and supply and fixing new Auto Switch of Racold Altro-2SP 25V/50V with setting range 30º C to 80 ºC suitable for 230 volts AC electric supply complete all as specified & directed. Make : Racold/Bajaj/Jaqauar
m/s varsha traders
M/s A.K. Trading Co.
M/s KKPARASHAR
Uma engineers
M/s YOGESH ENTERPRISES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .