| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹13.4 LAccepted-AOC 107 265 BRAHAMA NAGAR KANPUR UP 208012 | KANPUR NAGAR | UTTAR PRADESH | 208012 | L-1 | Accepted-AOC L-I Bidder | |
| 2 | L-2₹15 L+₹1.6 L (11.6%)Rejected-Finance 218 2ND FLOOR U S COMPLEX 120 MATHURA ROAD NEW DELHI 110076 | SOUTH | DELHI | 110076 | L-2 | Rejected-Finance L-II Bidder | |
| 3 | L-3₹16.0 L+₹2.5 L (18.9%)Rejected-Finance B 814 8TH FLOOR B G TOWER OPP DELHI GATE SHAHIBAUG ROAD AHMEDABAD 380004 | AHMADABAD | GUJARAT | 380004 | L-3 | Rejected-Finance L-III Bidder | |
| 4 | L-4₹16.2 L+₹2.7 L (20.2%)Rejected-Finance KARNATAKA | RAICHUR | KARNATAKA | 584123 | L-4 | Rejected-Finance L-IV Bidder | |
| 5 | Rejected-Technical 63 SECTOR 4 R FARIDABAD HARYANA 121004 | FARIDABAD | FARIDABAD | HARYANA | 121004 | - | Rejected-Technical Not Eligible for opening of Envelope-II |
Tender Value
₹16.4 L
Closing Date
8 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Senior Manager (Engg-E)
Airports Authority of India, TR-II, DATS Complex, IGIA, New Delhi
Replacement of 11KV 400 Amp Oil Circuit Breaker with similar capacity Vacuum Circuit Breaker at ARSR Bijwasan
2021_AAI_69846_1
AAI/DATS/E-E/2021-22/ENIT-08
Open Tender
Electrical Works
Item Rate
90 days
ARSR Bijwasan
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,180
Exempted
24 Mar 2021
26 Feb 2021
10 Mar 2021
26 Feb 2021
8 Mar 2021
26 Feb 2021
26 Feb 2021 - 2 Mar 2021
90 days
Amount
Supply Installation testing and commissioning of extendable type HT panel board suitable for indoor installation for use on 3 phase, 11 KV 50 Hz AC supplyearthed system having a short circuit capacity of 20KA for 3 Sec. at 11 KV comprising triple pole VCB. Panel shall be equipped with power pack back up of suitable capacity along with suitable accessories as per specifications and schematic drawing etc. Note: Plan of existing HT Panel in HT room is attached in the Tender Documents for reference.
(Vacuum Circuit Breaker Metal Clad housing with track having 800A TP integral VCB with Electrically operated draw out type mechanism (spring charged motor - 230 VAC). Air insulated copper bus bar & chamber. Isolating plug and receptacle. Automatic safety shutter. Breaker control switch (TNC) 24 V DC closing coil 24 V DC Shunt Trip Coil Operating Counter Mechanical ON/OFF Push Buttons Manual Spring Charged Device) Incomer-1, Outgoing-2 (Current Transformer [ Indoor Single Phase Resin Cast] Incomer : 300-150/ 5-5 A Outgoing: 100-50/ 5-5 A Class 0.5 and 5p20 burden 15 VA) Incomer-3, Outgoing-6 (Potential Transformer [Single Phase Resin Cast] PT's - 11KV /√3 /110V/√ 3 of class 0.5 (100 VA) Incomer-3, Outgoing-0 11 kv, 3.15 A P.T. fuse links Incomer-3, Outgoing-0 1 - H.T. Cable box for 3C x 240 sq.mm aluminium conductor XLPE cable (11 KV earthed system). Incomer-1, Outgoing-2 Digital Multi function Meter (V, A, F, KW, KVA, KVAH, KWH, PF) Incomer-1, Outgoing-2
(Protction relay and Accessories 3 O/c & 1 E/F Numerical Relay with inbult TCS, Incomer-1, Outgoing-2 Master Trip Relay, Incomer-1, Outgoing-2 Aux. relay for transformer Incomer-0, Outgoing-4 Antipumping Relay Incomer-1, Outgoing-2 Aux. Contactor - 2 NO + 2 NC - 24 V DC Incomer-1, Outgoing-2 Restricted Earth Fault Relay Incomer-1, Outgoing-2
(Indication Lamp & Accessories for complete panel Indicating Lamps (22.5mm DIA), 24VDC - set of 3 Breaker ON : RED Breaker OFF : GREEN Spring Charged : BLUE VCB Trip : AMBER Trip Circuit : WHITE Indicating Lamps (22.5mm DIA), 63.5 V AC - set of 3 R' Phase Healthy - RED Y' Phase Healthy - YELLOW B' Phase Healthy - BLUE MCB Double Pole ,10kA 6A Single Pole 10kA,6A Breaker Control Swtich (TNC) 25A, Double Pole Power Pack 230V AC / 24V DC Hooter 24V DC Strip Heater 100W, 240V AC Thermostate, 0-60ºC , 240V AC Emergency Stop Button 22.5mm OD 15A 240 V AC 3 pin power socket with ON-OFF switch, 18W LED, 240V AC, bulb, 2A, Door limit switch for cubical lamp, 10A, 240V AC, Toggle switch, 32A Neutral Link, C.T. Terminal 6mm end plate for above, P.T. Terminal 6mm end plate for above) Incomer-Outgoing- 1 LOT)
Dismantling of existing 3-phase, 11 KV 50 HZ AC supply HT panel consisting of 3 nos., 3- poles, 400 Amps Oil Circuit Breaker along with all the eletrical accessories, battery bank consisting of 12 nos., 2 V , 40 AH battaries. Including shifting of dismantled material from HT panel room to AAI store complete as required.
supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable(400 sq. mm) of 11 KV grade as required :
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm)
Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut,bolt, spring, washer excavation and re-filling etc. as required.
Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required
CIS GLOBAL INFRATECH PRIVATE LIMITED
jaydeep agency corporation
ECS ENGINEERING PVT LTD
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .