| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹10.4 LAccepted-AOC | 1 | Accepted-AOC Lowest and reasonable bid | |
| 2 | 2₹10.4 L+₹3,900 (0.38%)Rejected-Finance | 2 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
23 Dec 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE Bathinda
HQ CWE Bathinda, Bathinda Mil Station, Bathinda-151004
as per name of work
2020_MES_395674_1
CA NO CWE BTD 64 of 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Bathinda Mil Station
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE Utility Bathinda
₹32,000
Yes
19 Jan 2021
17 Nov 2020
25 Dec 2020
17 Nov 2020
23 Dec 2020
10 Dec 2020
17 Nov 2020 - 25 Nov 2020
60 days
Amount
Carrying out calibration of HT VCB panel of make: ABB/ SIEMENS/ CROMPTON, after taking proper shut down and disconnecting the cables from panel and VCB Breakers, calibration of over fault relay, earth fault relay, checking of alignment of VCB isolating contacts, servicing of operating mechanism including tripping and closing system of the breakers, dehydrating, decorbonising of panel, bus section & circuit section including incoming/ outgoing cable and necessary HT insulation at joints. Removing perished monoplus compound cleaning and re-insulating with HT taps wherever necessary, with and including replacement of wornout/ defective spares like tension springs, tortion springs, nut bolts, washers of suitable size, lingers etc, under the supervision of M/s ABB or authorised dealer/ representative and refing the panel in its original position and testing entire satisfaction of Engineer-in- charge. Note: (i) The quoted Rate shall be deemed to include all minor spares etc. (ii) If any burnt out/ defective items like moving/ fixed contracts, tripping coils, earth fault relay etc. (iii) Spare parts required other than mentioned here-in-after shall be deemed to be including in the quoted rate. (iv) The calibration test certificate to be submitted after servicing & testing in front of Engr-in-charge.
M& L for repair and servicing of 11 KV VCB including disassembly of operating mechanism parts, well cleaning with petrol & CRC-226, replacing of moving parts, re-assembly, fine setting of mechanism, replacement of unserviceable parts and re-assembly of parts including well cleaning the complete panel board main bus bar, de-carbonizing all joints, bus bar, CTs’ PTs spouts, metal parts and making VCB perfect operation in manual and electric mode including all routine and preventive maintenance all as specified and directed by Engineer-in-Charge. Note:- (i)Spares required shall be measured and paid separately under appropriate item of sch 'A'/BOQ. (ii)Cost of cleaning material like Urethane, Gasket remover, lubricant etc deemed to be included in quoted rate.
Supply only Shunt trip coil 220 /110volts DC
Supply only Closing coil 220/110 volts DC
Supply only monoblock assembly 600m suitable for ABB/CG/Siemens make breaker. .
Supply only 24 Pin Plug assembly suitable for ABB/CG/Siemens make HT breaker.
Supply only cable stem article No 1VYN400901-BH suitable for ABB/CG/Siemens make HT breaker.
Supply only contact system for VD4-630A (12 finger) suitable for ABB/CG/Siemens make HT breaker.
Supply only front cover assembly suitable for HT breaker.
Supply only Aux switch suitable for ABB/CG/Siemens make HT breaker.
Supply only spring drum V4205 suitable for ABB/CG/Siemens make HT breaker.
Supply only Spring V4207 suitable for ABB/CG/Siemens make HT breaker.
Supply only Roler Chain V4208 suitable for ABB/CG/Siemens make HT breaker.
Supply only Torsion Spring V4710/4711 suitable for ABB/CG/Siemens make HT breaker.
Supply only Lever Assembly V6014 suitable for ABB/CG/Siemens make HT breaker.
Supply only Motor cut off switch suitable for ABB/CG/Siemens make HT breaker.
Supply only On Off Indicator (Display) V6061 suitable for ABB/CG/Siemens make HT breaker. Make:- ABB/CG/Siemens
Supply only Spring charging motor for ABB/CG/Siemens make HT breaker.
Supply only HT self fusing tape insulation heavy duty suitable for insulation of 11 KV bus bar (38mmx0.76mmx10.0m). Make : Scapa/3M/Stanbac
Supply only insulation adhesive Urethane Isolation suitable for air drying conformal for coating in Electrical equipments, battery terminals, 11 KV bus bar etc in 300 ml bottle complete all as specified and directed by Engineer-in-Charge.
Supply only busbar insulator 11KV.
M& L in replacement of PF meter, three phase, analog type, size 144x144 mm dynamometer type LTR-/5A, PTR 3x63.5 with aux supply 110 V complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of PF meter digital type (4 digit) 1A/5A and 110V with built-in Transducer accuracy class + 2o, size 96x96 mm complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of Volt meter, analog type, DC, with moving coil of range (0-500V) with accu class 1 of size 144x144 mm complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of Digital voltmeter, DC, with phase range 200 mV to 600V with built in resistance of size 96x96mm, accu class 0.5 complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of Ammeter, digital type, 96x96mm with aux supply 220V complete all as specified and directed by Engineer-in-Charge.
Supply only vacuum interrupter 800/630 Amps, 11KV rating, suitable for ABB/CG/Siemens make VCB, per phase per interrupter all as required.
Supply only fixed contact assembly as per sample for ABB/CG/Siemens VCB make HT panel of 800/630 Amps 11KV rating.
M & L in replacement of Rubber gasket double ended flexible type suitable for mounting of glass in HT panel/metering window complete all as specified and directed by Engineer-in-Charge.
S & F in replacment of Current transformer (CT) ratio 400/200/5-5A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short cct time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper wiring and connections complete all as specified and directed by Engineer-in-Charge.
S & F in replacment of Current transformer (CT) ratio 200/100/5-5A, 50 Hz, 15 VA, accuracy class-I & 5P-10 , short cct time 18.4 KA for 1 sec, as per IS-2705 epoxy type suitable for 11 KV, VCB breaker including all necessary fixing arrangements and proper wiring and connectionscomplete all as specified and directed by Engineer-in-Charge.
M & L in replacement of Sticker with radium red or any colour as directed duly writing name of E/M plants size of alphabets/ numbers 50mm complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of Danger notice plate of 1.6mm thick mild steel sheet of size 25x20 cm, pasting with Sticker in radium red colour with writing 132 KV, figures and conventional skull and bones size, for HT 132000 volts complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of HRC fuse 4 A to 32 A suitable for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge.
M & L in replacement of HRC fuse 40 A to 63A suitable for fixing in control circuit of VCB complete all as specified and directed by Engineer-in-Charge.
M&L for preparation of the old painted surfaces of HT VCB panel of any size, any description and in any position including complete removal of old paint either by hand scrubbing or by blow lamps, applying necessary filler coat and scraping as required and applying two coats of grey colour synthetic enamel paint over a coat of zinc chrome primer using spray machine complete all as directed.
S & F in replacement of adjusting insulator suiable for 630 Amp VCB complete all as specified and directed by Engineer-in-Charge. Make : S&S power limited/ABB/Siemens
S & F in replacement of push button assembly suitable for make:- CG/ABB/Siemens complete all as specified and directed by Engineer-in-Charge.
S & F breaker control switch (Trip-Neutral-Close) 4 pole/4 Terminal 660 V AC / DC pistol grip type complete all as specified and directed by Engineer-in-Charge.Make : Switron or other make as approved by Accepting Officer.
M&L for CPRI tested Indian / International Standards IS: 13573/1992/IEC: 60502/ CENELEC; HD 628.1 & 629.1/ 1EEE; 48/VDE; 0278 Cold shrinkable end termination joint indoor type dielectric strength 15 KV/mm, tensile strngth 1x10E12 N/Sqmm, Elogation 300%, Volm Resist 1x10E11 Ohm.cm suitable for HT XLPE cable of size 50 to 95 sqmm 3 core armoured 11000 volt grade heavy duty.
All as per item No 40 above but suitable for cable of size 120 to 185 Sqmm 3 core armoured 11000 volt grade heavy duty.
All as per item No 40 above but suitable for cable of size 240 to 300 Sqmm 3 core armoured 11000 volt grade heavy duty.
S & F of nominal 2.5mm + 10% thick insulated synthetic Mat conforming to IS 15652:2006 alongwith suitable adhesive/chemibound, Pu resin, waterprofing compound and sealing material and similar tape of matching colour and matching design, tapes should be used to maintain aesthetic look of the insulation over the joints and corner as per service recommendation and suitable for Class-B upto 11KV with HT trolley movement all as specified and directed by Engineer-in-Charge.
Supply only CRC-2-26 power spray in 400ml bottles complete all as specified and directed by Engineer-in-Charge.
Supply only HT insect killer power spray in 450ml bottles complete all as specified and directed by Engineer-in-Charge.
M & L for taking out old defective 11 HT switch gear complete disconnecting HT elect supply including replacement of old type breaker system with supply, install testing and commissioning HT 11/12 KV 3 phase 50 cycles of make: ABB/ SCHNEIDER/ CG, totally enclosed metal clad with drawable type vacuum switch gear AIS UNIVAC panel stand alone type having rupture capacity 350 MVA as per ISO 9001 and IS 14001 certification and as per IEC 62271-200 & IS 3427-1997 with short circuit rating 18.4 KA for 3 sec having CT primary current 200 Amps, busbar current 1250 Amps horizontal isolation horizontal draw out type vacuum circuit breaker with copper bus bar of suitable rating floor mounting trolley mounted complete with following: (a) Mannually operated spring charged trip free-type incorporating mechanical operated all as specified and directed.
M & L including filling of SF6 gas in 132 KV circuit breaker upto level as per manufacturer's instructions and testing complete all as specified.
S & F in replacment maintenance free battery, 12 Volt, 150 AH lead acid type suitable for inverter purpose complete all as specified and as directed. Make of battery: Exide/Luminous/Amron/Tata/Amco
Replacement of burnt parts / electronic spares of booster battery charger complete all as specified and directed by Engineer-in-Charge. (Any electronic part replaced shall be measured and paid for separately under respective items of this schedule)
Supply only transformer buck boost with auto cut off function.
Supply only PCB for boost battery charger.
Supply only wiring kit for boost battery charger.
Supply only voltmeter for boost battery charger.
Supply only ammeter for boost battery charger.
Supply only O/C relay for boost battery charger.
S & F in replacment maintenance free battery, 2 Volt, 40 AH lead acid type suitable for inverter purpose complete all as specified and as directed. Make of battery: Exide/Luminous/Amron/Tata/Amco
S&F in replacement 24 Volt pure sine wave inverter of 2 kVA DIP switch, auto mode 50 HZ, 6 stage charger for large battery life, input voltage 100 to 280 V, low cut recovery input voltage 90 V, high cut input voltage 280V, recharge time max 8 hrs, for 2 battery system, battery boost system, battery charging current 15A, compatible for sealed maintenance free lead acid tubular battery protection against high and low voltage overload, with onsite 36 months warranty complete all as specified. (Make- Microtek/Luminous/Sukam)
Supply only digital inverse current protection / control relay suitable to work on 24V/12V DC supply as per sample of HT panel of 800/630 Amp, 11 KV rating VCB of make ABB/CG/Siemens.
S&F in replacement control panel relay of power transformer.
M & L in replacement of Flag coil for RASVP relay type ICM21P A : 0.5-2.0 at 220V DC supply complete all as specified and directed by Engineer-in-Charge.
Supply only fixed contact assembly as per sample for ABB/CG/Siemens VCB make HT panel of 1200/800/630 Amps 11KV rating.
S & F 11KV potential transformer PT ratio 11000/110V accuracy class 0.5, 50 VA, indoor type, epoxy resin cast, strut type single stage suitable for power measurement current monitoring and relay protection in power system with rated frequency 50 Hz and rated voltage 10 kV all as specified and directed.
S & F in replacement of HT feeder pillar box factory made cubical type dust and vermin proof, outdoor type, both side opening of size 110 x 100 x 60cm of CRCA sheet 3 mm thick powder coated, machine pressed front opening in two halves with rubber gasket/bedding, locking arrangement with sliding bolt including aluminium bus bar of size 50 x 10 mm and 80 cm long 3 strips mounted on HT insulators. Each strip should be mounted minimum two insulator and nut bolt, panel shall be mounted on angle iron frame including heat shrinkable sleeve and legs made from angle iron of size 50 x 50 x 6 mm and legs 40 cm long duly spray painted internally and externally with two coats of synthethetic enamel paint over a coat of red oxide primer and including grouted in PCC (1:2:4) type B-1 (using 20mm graded stone aggregate) complete incoming/outgoing cable and earth work such as excavation and removal of surplus soil etc.
PREM ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .