Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.9 LAccepted-AOC HOUSE NO 22 BHAGADUTTAPUR BELTOLA RUKMINIGAON ROAD GUWAHATI 781028 | KAMRUP METRO | ASSAM | 781028 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹10.4 L+₹44,150 (4.42%)Rejected-AOC H M APARTMENT 4C S J ROAD ATHGAON GUWAHATI 781001 | GUWAHATI | KAMRUP METRO | ASSAM | 781001 | L2 | Rejected-AOC Not being L1 bidder | |
| 3 | L3₹10.5 L+₹55,400 (5.55%)Rejected-AOC | L3 | Rejected-AOC Not being L1 bidder | |
| 4 | L3₹10.5 L+₹55,400 (5.55%)Rejected-AOC C O GP WORLD PATHARQUARY PO UDAYAN VIHAR PS NOONMATI GUWAHATI 781177 ASSAM | 781177 | L3 | Rejected-AOC Not being L1 bidder | |
| 5 | L4₹10.8 L+₹78,100 (7.82%)Rejected-AOC | L4 | Rejected-AOC Not being L1 bidder |
Tender Value
Refer Docs
EMD Value
₹19,800
Closing Date
22 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) AF Digaru
AGE (I) AF Digaru PO Digaru Dist Kamrup Assam 782401
REPAIR / MAINT OF METERING EQUIPMENT, CHANGEOVER SWITCHES, DISPLAY SENSORS AND OTHER MISC WORKS AT AF STN DIGARU.
2022_MES_549657_1
8590/E8 of 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Digaru
Please refer Tender Documents.
5 documents required · 5 mandatory
₹500
Yes
AGE (I) AF Digaru
₹19,800
Yes
3 Nov 2022
3 Sept 2022
24 Sept 2022
3 Sept 2022
22 Sept 2022
17 Sept 2022
Amount
Taking down old unservicable rolling shutter motor of input power 1013 watt and rated load of 1000 kg from existing postion, carring out major/minor repair like replacement of u/s bearing, break ,cap, limit swich, gear box, driver gear including rewinding of motor and installing testing and commissioning the same at original position complete all as specified and directed by Engr-in-Charge. Make of motor:- Jielong
M & L for repairing/servicing of electrically operated shutter operating mechanism at parking/storage areas of TP complex complete for both electrical as well as manual operation of the shutters, by checking/repairing of all the parts/systems, cleaning and tightening of all contacts & electrical connections, oiling/lubrication of the gears, bearing & chains etc, checking and properly tightening of all the hardwares, replacing worn out / rusted nuts/bolts/washers etc with new one, checking and setting the mountings for proper alignment and for smooth/trouble free opening/closing of the shutters, checking insulation value of the motor and testing the sysytem for automatic (electric motor mode) and manual operation for trouble free opening and closing of the shutters complete all as specified and directed by Engr-in-Charge.
Maintenance of existing APFC panel and cleaning of dust inside the cabniet with blower,cleaning of moving parts/contacts from CT cleaner,tightening of loose parts/electrical wires,cleaning of contactors,relays and capacitors junction points,servicing/oiling to cooling fan,complete testing of APFC relay with necessary setting with CTs/load adjustments to match with APFC load management system complete with replacement of worn out u/s components/ burnt wire thimbles/lugs complete tested of cap 300 and 375 KVAR complete all as specified and directed by Engr-in-Charge. NOTE : - (i) Rate of minor parts/components for replacement shall be included in the unit rate quoted. (ii) APFC Panel should be attended throughly and servicing shall be done to the full satisfaction of the Engr-in-Charge.The payment shall be made after complete testing of the AFPC panel. (iii) Replacement of small nuts/screws,burnt copper wires/lugs or thimbles/cleaning materials or CTC shall not ce paid separately,the cost of these are deemed to include the schedule item rate. (iv) The parts should be of the same make and capacity of existing one which is required to be replaced.
Servicing of ACBs by taking out Air circuit breakers of capacity 1250 to 1600 Amps from LT panels cleaning all parts internally and externally checking of the proper tension of the springs mechanical mechanism,tightening of connection of moving,fixed contact,floatin contacts,servicing of motor,and charging system lubricating the operating/spring charging/tripping mechanism,cleaning contacts with fine emery paper and CTC and re-fixing it on its original position and testing including testing of control wiring of the respective ACBs complete all as directed by Engr-in-Charge. Note:- Rate is deemed to include minor items ie,jelly,grease,s/c copper cable upto 1.5 sqmm,screws & locking system.
All as per above item No 4.00 but of capacity 800 Amps
S & F in replacement of 11 KV panel indicating lamp fitting LED type suitable for 110 volt/230 volt AC complete with base complete all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of 3 phase multifuction digital meter compatible to measure current,voltage,power factor & frequency with 3 lines LCD display in 96 x 96 sqmm flush mounted case,accuracy class 1.0 for panel complete all as specified and directed.
Disconnecting and taking out existing HT 11 KV VCBs, of any make from housing and cleaning ,rubbing and overhauling the mechanical parts and servicing of 11 KV indoor VCB,checking of quality of vaccum interrupter,insulation resistances,static contact resistance,testing (IR value,Ratio test,Polarity test) and connection verification of 11 KV current transformer (set of three) by primary injection kit,and testing and calibration of relay (set of two over current and one earth fault) by secondary injection kit including all other functional tests of VCB,C&R panel and CTs,PTs complete all as specified and directed by Engr-in-Charge.
Taking out unservicable VCB breaker incoming and outgoing from VCB of cap 650 Amp,cleaning contacts with fine emery paper and applying petroleum jelly on the contacts,refixing at original position and testing for proper working including replacement of heating contact and insulation materials and refixing the same at existing position complete all as specified and directed.
Repair to battery bank charging panel of VCB 220 volts input and 24 volt output with replacement of burnt electric circuit and transformer complete all as specified and directed.
M&L for replacement of the following items from the panel board with replacing the u/s including disconnecting/connecting all the cable/bus bars connections for input and out supply with necessary jointing materials complete all as specified and directed by Engr-in-Charge. Note : The make should be of the same size as of existing MCCB to match with existing holes/surfaces.
Supply and fix in replacement MCCB 250 Amps,3 pole 36 KA breaking capacity,adjustable thermal & adjustable magnetic setting.
Supply and fix in replacement MCCB 100Amps, 4 pole 36 KA breaking capacity.
Supply and fix in replacement MCCB 63 Amps, 3 pole , 25 KA breaking capacity
Supply and fix in replacement MCCB 125 Amps TP 25 KA 415 volts and making all connections complete all as directed.
Supply and fix in replacement MCCB 200 Amps,4 pole 25 KA breaking capacity,adjustable thermal & adjustable magnetic setting.
Supply and fix in replacement MCCB 160 Amps,4 pole 25 KA breaking capacity,adjustable thermal & adjustable magnetic setting.
Earthing complete with GI earth plate electrode of size 60cmx60cmx6mm buried directly in ground vertically at a depth not less than 2.25 m below normal ground level with top edge of earth plate at a depth not less than 1.5 mm below ground level surrounded from all sides by 15 cm thick layers of charcoal dust and common salt filled in alternate layers etc and connected to and including 32x6 mm GI strip upto 7.5 mtr by means of bolts,nuts,check nuts and washers made of galvanised iron and protected by light grade 40mm dia GI pipe connected to main control board and GI pipe medium grade 15 mm bore for watering and including funnel,wire mesh charcoal salt etc RCC pit cover flush to earth pit 50 mm thick reinforced with 8 mm TMT bar 100 mm C/C and PCC chamber pit with PCC (1:3:6) type C1(using 20 mm graded stone aggregate) including exacavation and earthwork disposal of surplus soil to a distance not exceeding 50 m and testing after completion all as specified and shown on electrical plate No 3 of SSR Part-I complete all as specified and directed by Engr-in-Charge.
Repair to DG set synchronization control panel of 2x500 KVA DG set installed at TP area by rectifying the defects and checking all the parameters like auto mains failure,auto DG on off,feed back control in DG, DG automation and mainly parallel DG operation to be working satisfactorily after rectifying the defects to the full satisfaction of Engr-in-Charge. Note: Rates of spare parts reqd for the above work shall be included in the unit quoted rate.
M&L for replacement of old unservicable manual changeover switch current rating 250 Amps 415V,AC,4P conforms to IEC 60947-3 with terminal shrouds,source separator and phase barrier suitable for horizontal as well as vertical mounting and to meet the existing unservicable change overswitch i.e to be replaced complete all as specified and directed by Engr-in-Charge.
Supply and laying cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured,electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 120 sqmmx 3.5 core and taking out old unservicable cable of same size complete all as specified and directed by Engr-in-Charge.
M& L for replacement of old unservicable LT panel and supplying,installation ,commissioning and testing of factory made type dust and vermin proof,totally enclosed control panel indoor type CPRI approved fully comparted type,fabricated out of 3.15mm thick CRCA sheet,duly painted with epoxy powder coating with 10 tank process,with IP-65 protection complete,with provn of front double door shutter with locking arrangement mounted on MS angle iron frame of 50x50x5mm and legs grouted on PCC foundation 30 cm below the ground and 20 cm above thye ground,duly powder coated paint over one coat of red oxide primer complete all as directed comprising the following:- i) Copper Bus bar TPN 750 Amps of suitable length and cross section covered with coloured heat shrinkable anti track insulation tape of make Denson/M-seal oe equivalent of finished thickness not more than 1 mm and fixed on epoxy base post insulator of both dia and height not less than 40mm - 01 set ii) MCCB 4 pole 630 Amp, Ics 50 KA,415 V,50 Hz,with adjustable thermal and fixed magnetic release-01 No (incomer) iii) MCCB 4 pole 400 Amp, Ics 36 KA,415 V,50 Hz,with adjustable thermal and fixed magnetic release-02 No (Outgoing) iii) Indicator lamp RYB-01 Set iv) Multifunction meter digital compatible to measure voltage,current,PF,frequency with 3 lines display LCD in 96x96 sqmm flush mounted case,accuracy class 1.0-01 No. v) Control wiring with suitable size copper conductor stranded wire/cable. vi) Danger notice plate riveted on the outer body 440 volts.
M/S. SUBHAS CONSTRUCTION CO.
SANJIB DAS
M/s Dhruv Enterprises
M/s Capital Traders
M/S TRADE CENTRE
M/S Vimal Enterprise
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .