Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC LINE PAR NAI BASTI OSARH ROAD FARIDPUR DISTT BAREILLY PIN 243503 | FARIDPUR | BAREILLY | BAREILLY | 243503 | L1 | Accepted-AOC being L1 | |
| 2 | L2₹21.9 L+₹6.2 L (39.8%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹22.4 L+₹6.8 L (43.2%)Rejected-Finance GATE NO 1 RAKHAIJUNGLE KHARAGPUR DISTT PASCHIM MIDNIPUR WEST BENGAL PIN 721303 | KHARAGPUR | PASCHIM MIDNIPUR | WEST BENGAL | 721303 | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹23.2 L+₹7.6 L (48.6%)Rejected-Finance VILL KADUA PO HARIATARA DISTT PASCHIM MEDINIPUR WB PIN 721304 | HARIATARA | PASCHIM MEDINIPUR | WEST BENGAL | 721304 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹23.6 L+₹7.9 L (50.6%)Rejected-Finance KHEMASULI P S KHARAGPUR LOCAL DIST PASCHIM MEDINIPUR WEST BENGAL | KHARAGPUR | PASCHIM MEDINIPUR | WEST BENGAL | L5 | Rejected-Finance Not being L1 |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
16 Dec 2020, 6:00 pmClosed
GE (AF) Kalaikunda
GE (AF) Kalaikunda
REPAIR AND MAINTENANCE TO STAND BY DG SET AT AIR FORCE STATION KALAIKUNDA AND DDK RANGE UNDER GE (AF) KALAIKUNDA
2020_MES_396549_1
8607/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (AF) Kalaikunda
AS PER NIT
6 documents required · 6 mandatory
₹500
Yes
GE (AF) Kalaikunda
₹40,000
Yes
22 Mar 2021
19 Nov 2020
18 Dec 2020
19 Nov 2020
16 Dec 2020
4 Dec 2020
20 Nov 2020 - 21 Nov 2020
Amount
Comprehensive maintenance for the following DG sets installed at various location by cleaning, Oiling,Greasing, topping, calibration, repairs to diesel engine and including replacement of spares parts like clamps, V- Belt of any size,pipe with fittings, check the level of coolant in radiator, repairs to leakage in radiator etc. Gaskets & Oil seals, servicing of the Water Pump, calibration of fuel injection pump,repairs of Self Starter, Alternator, Auto Voltage Regulator, Battery maintenance by topping up of electrolite solution, rectification of engine oil leakage and topping up of engine oil, replacement of unserviceable oil level tube provided on the fuel tank for checking of oil level (The same is to be calibrated and level marked on the tank), repair of wiring of control panel of DG set by replacement with suiatable size of copper wire including Repair/Replacement off toggle switch etc & connected accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified
a) 320/400 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
b) 250 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
c) 200 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
d) 160 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
e) 125 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
f) 100 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
g) 82.5 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
h) 63 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
i) 50 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
j) 40 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
l) 30 KVA DG of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
m) 20 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
Supply and filling in replacement of Engine oil 20W 40 to top up/ refilling of all DG set as per the direction of Engineer-in-charge.(Make Gulf/Castrol/Volvalin as per OEM specification
Supply only of Premix Coolent of radiater water for carrying out 'B' check maintenance under SL No-1 above.Make Bharat/Greaves or Equivalent
Supply only of Lub Oil filter element with 'O' ring, of make Kirloskar/Kirloskar Green/ BOSCH / Greaves as per OEM specification for carrying out 'B' check maintenance for the DG set of various capacities and make as indicated below:-
a)320/400 KVA DG Set at Power House,Base Ops,33 KV MRS, I-Lab, RSAF Airmen billet and Visiting Sqn of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
b) 250 KVA DG set at WSA./DWR/DDK Range of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
c) 200 KVA DG set at MAFI PS-II of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
d) 160 KVA DG set at ATC and Base Ops. ofMake : Greaves /Kirloskar Green/ Kriloskar Bliss
e) 125 KVA DG set at 4AFH, GCA power house,ATC,Auditorium& Power House ofMake : Greaves /Kirloskar Green/ Kriloskar Bliss
f) 100 KVA DG set at WSA(PH-12) of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
g) 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
h) 63 KVA DG set at BSO Yard of Make : Ashok Leyland./ Greaves /Kirloskar Green/ Kriloskar Bliss
i) 50 KVA DG Set at Transmitter Bldg of Make: Leyland/Cummins./ Greaves /Kirloskar Green/ Kriloskar Bliss
j) 40 KVA DG Set at P.H. No-12(CWE Office) and DDK Range of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
k) 30 KVA DG Set at CADF of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
l) 20 KVA DG Set at 17 End arrester barrier,DDK Range of Make: Kirloskar/Kirloskar Bliss/Kirloskar Green
Supply only of Fuel filter element with 'O' ring,of make Kirloskar/Kirloskar Green/BOSCH/Greaves as per OEM specification for carrying out 'B' check maintenance for the DG set of various capacities as indicated below:-
a)320/400 KVA DG Set at Power House,Base Ops,33 KV MRS, I-Lab, RSAF Airmen billet and Visiting Sqn of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
b) 250 KVA DG set at WSA. of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
c) 200 KVA DG set at MAFI PS-II of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
d) 160 KVA DG set at ATC and Base Ops. of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
e) 125 KVA DG set at 4AFH, GCA power house,ATC,Auditorium& Power House of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
f) 100 KVA DG set at WSA(PH-12) of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
g) 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
h) 63 KVA DG set at BSO Yard of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
i) 50 KVA DG Set at Transmitter Bldg of Make: Leyland/Cummins./ Greaves /Kirloskar Green/ Kriloskar Bliss
j) 40 KVA DG Set at P.H. No-12(CWE Office), DDK Range of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
k) 30 KVA DG Set at CADF of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
l) 20 KVA DG Set at 17 End arrester barrier,DDK Range of Make: Kirloskar/Kirloskar Bliss/Kirloskar Green
Supply only of Air filter element and Vaccutator Valve for air cleaner, of make Kirloskar/Kirloskar Green/BOSCH/Greaves as per OEM specification for carrying out 'B' check maintenance for the DG set of various capacities as indicated below:-
a)320/400 KVA DG Set at Power House,Base Ops,33 KV MRS, I-Lab, RSAF Airmen billet and Visiting Sqn of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
b) 250 KVA DG set at WSA. of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
c) 200 KVA DG set at MAFI PS-II of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
d) 160 KVA DG set at ATC and Base Ops. of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
e) 125 KVA DG set at 4AFH, GCA power house,ATC,Auditorium& Power House of Make : Kirloskar Bliss/Kirloskar Green.
f) 100 KVA DG set at WSA(PH-12) of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
g) 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
h) 63 KVA DG set at BSO Yard of Make : Ashok Leyland/Greaves /Kirloskar Green/ Kriloskar Bliss
i) 50 KVA DG Set at Transmitter Bldg of Make: Leyland/Cummins.
j) 40 KVA DG Set at P.H. No-12(CWE Office), DDK Range of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
k) 30 KVA DG Set at CADF of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
l) 20 KVA DG Set at 17 End arrester barrier,DDK Range of Make: Kirloskar/Kirloskar Bliss/Kirloskar Green
Takingdownt worn out and Replacement of Fan Belt for dynamo of Make: Kirloskar /Fenne /Dunlop/ Kirloskar green as per OEM specification for the following DG Sets:-
a)320 /400 KVA DG Set at Power House,33 KV MRS, I-Lab, RSAF Airmen billet, Base Ops and Visiting Sqn ofMake : Greaves /Kirloskar Green/ Kriloskar Bliss
b) 250 KVA DG set at WSA. of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
c) 200 KVA DG set at MAFI PS-II of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
d) 160 KVA DG set at ATC and Base Ops. Of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
e) 125 KVA DG set at 4AFH, GCA power house,ATC,Auditorium& Power House of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
f) 100 KVA DG set at WSA(PH-12) of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
g) 82.5 KVA DG Set at 771 SU, HQ Signal Centre and 18 Sqn Hanger of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
h) 63 KVA DG set at BSO Yard of Make : Ashok Leyland/ Greaves /Kirloskar Green/ Kriloskar Bliss
i) 50 KVA DG Set at Transmitter Bldg of Make: Leyland/Cummins/ Greaves /Kirloskar Green/ Kriloskar Bliss
j) 40 KVA DG Set at P.H. No-12(CWE Office), DDK Range of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
k) 30 KVA DG Set at CADF of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
l) 20 KVA DG Set at 17 End arrester barrier,DDK Range of Make: Kirloskar/Kirloskar Bliss/Kirloskar Green
Taking down and replacement of Radiator Fan Belt of Make Kirloskar/Kirloskar Green as per OEM specification of the following DG set
a) 400 KVA DG set at Visiting Sqn of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
b) 125 KVA DG set at GCA power House of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
c) 160 KVA DG set at Base Ops of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
d) 250 KVA DG Set at WSA of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
e) 82.5 KVA DG Set at HQ signal Section of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
f) 50 KVA DG Set at Transmitter of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
(g) 40 KVA DG Set at DDK Range and CWE Office Make : Greaves /Kirloskar Green/ Kriloskar Bliss
(h) 20 KVA DG Set at 17 End arrester barrier,DDK Range of Make: Kirloskar/Kirloskar Bliss/Kirloskar Green
Taking out Water Pump Including replacement of complete assembly as Gasket, Bearing,Hose pipe, rubber seal & clamp of make Kirloskar/Kirloskar Green/BOSCH/Greaves as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified for the following DG Sets:-
a)400 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
b) 250 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
c) 200 KVA DG MAFI PS-II of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
d) 160 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
e) 100 KVA DG of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
f) 82.5 KVA DG Set Make : Greaves /Kirloskar Green/ Kriloskar Bliss
g) 63 KVA DG set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
h) 50 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
j) 40 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
k) 30 KVA DG Set of Make : Greaves /Kirloskar Green/ Kriloskar Bliss
Taking down and replacement of shut down valve for the DG set of capacity 50 KVA as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE Make of DG Set : Leyland/Cummins/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking down and replacement of shut down valve as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GEfor the DG set of capacity 400 KVA Make of DG Set :: Greaves /Kirloskar Green/ Kriloskar Bliss
Taking down and replacement of shut down valve as per OEM specification of make for the DG set of capacity 200/250 KVA Make of DG Set :Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Taking out and repalcement of oil presure meter as per OEM specification for 63 KVA DG set Make: kirloskar/Ashok Leyland/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Takingout and repalcement of oil presure meter as per OEM specification for 125 KVA DG set Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Takingout and repalcement of oil presure meter as per OEM specification for 160 KVA DG set Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Takingout and repalcement of oil presure meter as per OEM specification for 82.5 KVA DG set Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Taking down and replacement of Water temperature meter as per OEM specification for 40 KVA DG Set .Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Taking down and replacement of Water temperature meter as per OEM specification for 125/250 KVA DG Set .Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of solenoid switch, pinion, Auxiluary coil, carbon brush as per OEM specification for the DG set of capacity 20 KVA Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Takingout burnt/unservieable self starter and refixing after necessary repair including replacement of solenoid switch, pinion, Auxiluary coil, carbon brush as per OEM specification for the DG set of capacity 30 KVA Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable self starter and refixing after necessary repair including replacement of solenoid switch, pinion, Auxiluary coil, carbon brush for the DG set of capacity 63/82.5 KVA Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable self starter and refixing after necessary repair including replacement of solenoid switch, pinion, Auxiluary coil, carbon brush as per OEM specification for the DG set of capacity 160 KVA Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable self starter and refixing after necessary repair including replacement of solenoid switch, pinion, Auxiluary coil, carbon brush as per OEM specification for the DG set of capacity 250 KVA Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable self starter and refixing after necessary repair including replacement of solenoid switch, pinion, Auxiluary coil, carbon brush as per OEM specification for the DG set of capacity 400 KVA. Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 400 KVA. Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 250 KVA. Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 160 KVA. Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable alternator assembly and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 125 KVA. Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable alternator assembly and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 82.5 KVA. Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable alternator assembly and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 20 KVA.Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out burnt/unservieable Dynamo and refixing after necessary repair including replacement Main coil, axuilary coil and carbon brush as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 50 KVA.Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Taking out and replacement of complete self starter of Make AUTOLEK or as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE the DG set of Various capacity as mentioned below:-
a) 63 KVA DG Set of Make: Ashok Leyland./kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
b) 400 KVA DG Set MMake: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss/Kirloskar Green/ Kriloskar Bliss
c) 250 KVA DG Set Make: Greaves
(d) 160 KVA DG Set Kirloskar
M&L for fixing of Door Hinges as per OEM specification for the DG Set of various capacity through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE Make: Kirloskar/Kirloskar Green/Greaves
M&L for fixing the asbestos rope on silencer as per OEM specification of DG set of various capacity including cladding with asbestos powder over wire mesh. through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for cleaning of the fuel tank by vacating the tank, replacement of fuel level indicator and spray painting of tank by scraping the existing paint using enamel paint of two coat as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set varying from 20-125 KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
Maintenance and servicing of alternator by removing of dust and moisture from field coil and armature coil by blowing the hot air for the various capacity of DG set varying from 125-400KVA through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Replacement of Voltage regulator Device (AVR) as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 20 to 50 KVA of Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Replacement of Voltage regulator Device (AVR) as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 63 to 100 KVA of Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Replacement of Voltage regulator Device (AVR) as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 125 to 250 KVA of Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L for Replacement of Voltage regulator Device (AVR) as per OEM specification through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE for the DG set of capacity 315 to 400 KVA of Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L earthing complete with copper earth plate electrode 600mm x 600mm x 3 mm thick burried directly in ground (Earth pit not less than 3 m deep below ground level) with top edge of the plate not less than 2.2 m below ground level connected to copper strip 20 x 3 mm as earth lead by brass nut bolts washer including brazing the copper strip with copper plate as shown in electrical plate No 3 connected to earth test point including necessary excavation any type of soil, filling charcoal and salt around the plate in layers , filling the pit with agriculture soil free from stones, to be bring from out side defence land, construction of PCC earth pit chamber, RCC chamber cover plate, wire mess, funnel, test point, 40 mm dia GI protection pipe light grade and 32 mm GI peforated pipe for watering etc complete and testing on completion. The electrode and lead shall be of copper all as specified and directed by Engr-in-charge (Copper strip upto 7.5 RM will be included in the item rate and copper strip beyond 7.5 RM will be measured seperately. (NOTE: 1. The unit rate includes for protection GI pipe and watering pipe of 40 mm bore including excavation for earth pit in any type of soil/ disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to achieve desired result as the soil resistiviy is very high are deemed to be included in the unit rate.. 3.The cost of Copper strip of size 20X3 mm from top of earth plate upto 7.5 meter above ground level is deemed to be included in the unit rate of above item.and copper strip beyond 7.5 RM will be measured seperately. 4. All the joints in copper strip and connection with Earth Plate to be welded through brazing and in addition by proving brass nut bolt and washer are deemed to be included in the unit rate. 5. Cost of brazing / welding and nut bolts are deemed to be included in the unit rate.6. Cost includes removal of excavated soil upto a distance of 100 mtrs.
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 82.5 KVA DG set by taking shut down from Main Power House , including replacement of accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed. : (Note : Supply only accessories will be measured and paid separately):--
(a) Supply only Digital Amp meter as per OEM specification of range 0-30 Amp
(b) Supply only Digital Voltmeteras per OEM specification of range 0-30 Volt
(c ) Supply only Digital frequency meter as per OEM specification of range 48-52 HZ
(d) Supply only Indicator lamp of R-Y-B Phase as per OEM specification
(e) Supply only 160A HRC fuse Make: L&T/SIEMENS or Equivalent /(AS per sample)
Repair/Servicing of AMF Panel and ATS and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 400 KVA DG set by Taking shut down from Main Power House , including replacement of accessories through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE, complete all as specified and as directed.: (Note : Supply only accessories will be measured and paid separately):--
(a) Supply only Auto transfer as per OEM specification switch suitable 400 KVA
(a) Supply only Digital Amp meter of range 0-30 Amp as per OEM specification
(b) Supply only Digital Voltmeter of range 0-30 Volt as per OEM specification
(c ) Supply only Digital frequency meter of range 48-52 HZ as per OEM specification
(d) Supply only Indicator lamp of R-Y-B Phase.as per OEM specification
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 125/250 KVA DG set by Taking shut down from Main Power House , including replacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
a) Supply only Panel battery charger of rating: Input 220 V Ac 50 Hz,Output 24 /12V 10 A Dc as per OEM specification of Make: NHP or Equivalent
(b) Supply only Digital Amp Meter as per OEM specification Make: L&T or Equivalent
(c) Supply only 3- phase, 415 V, 45-65 Hz Multi function Meter as per OEM specification of Make -L&T or Equivalent
(d)Takingout/servicing and refixing of power contactor 4 pole 250 to325 Amps through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE,
(e) Supply Only Digital Voltmeter of make as per OEM specification L&T or Equivalent
(f) Supply Only AMF Controller as per OEM specification Make: Kirloskar/Procom or Eqv.
(g) Supply only 225A HRC fuse as per OEM specification Make: L&T/SIEMENS or Equivalent /(AS per sample)
(j) Supply only Start & Stop Relay 30Amps,24 Volt as per OEM specification
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 63 KVA DG set by Taking shut down from Main Power House , including eplacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
(a) Supply only 63 A 4- pole contactor as per OEM specification of make: L&T, Model MCX 12 or Equivalent
(b) Supply only 63 A HRC fuse as per OEM specification Make: L&T/SIEMENS or Equivalent /(AS per sample)
(c) Supply only AMF Controller as per OEM specification Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
(d) Supply only battery charger of rating 12/24 V 10 A as per OEM specification Make: kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
(e)Supply only Digital Amp Meter as per OEM specification Make of DG set : kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
(f) Supply only Digital Voltmeter rating 0-30V DC as per OEM specification Make of DG set : kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Blisst
(j) Supply only Start & Stop Relay 30Amps,12 Volt
Repair/Servicing of AMF Panel and rewiring of the defected wiring connection of AMF panel by proper connection using thimble for 20 KVA DG set by Taking shut down from Main Power House, including replacement of accessories : (Note : Supply only accessories will be measured and paid separately):--
(a) Supply only Digital Amp Meter as per OEM specification of Make of DG set : kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
(b) Air break power contactor, 240 volt, AC-I 40 amps, Make -L&T, Model No- MNX 40
(c )Supply only Oil level indicator meter as per OEM specification Make- Kirloskar or Equivalent
(d ) Supply only Push switch Start, Stop & Reset as per OEM specification Make- L&T Or Equivalent
(e) Supply only Battery charger of rating 12/24 Volt 10 A rating of s per OEM specification Make NHP or Equivalent
(f) Supply only R-Y-B phase indicator as per OEM specification Make L&T or Equivalent
(h) Supply only Start & Stop Relay 30Amps,12 Volt as per OEM specification Make of DG set : kirloskar/Bosch/Greaves /Kirloskar Green/ Kriloskar Bliss
M&L For replacement of AMF controller unit for the DG Set of capacity 400 KVA as per OEM specification of Make: Kirlosar/Procom/ or Eqv.
M&L For replacement of AMF controller unit for the DG Set of capacity 160 KVA as per OEM specification of Make: Kirlosar/Procom/ or Eqv.
M&L For replacement of AMF controller unit for the DG Set of capacity 63/82.5 KVA as per OEM specification of Make: Kirlosar/Procom/ or Eqv.
M&L For replacement of AMF controller unit for the DG Set of capacity 125 KVA as per OEM specification of Make: Kirlosar/Procom/ or Eqv.
M&l for taking out and replacement of Indicator lamp for R-Y-B phase. Make L&T Or Equivalent
M&L for Taking down and replacement and connection of Panel battery Charger of rating : Input 240V, 50 HZ and Output 12V, 5 A as per OEM specification. Make- NHP or Equivalent
S&F and testing for fixing of 150AH,12 Volt lead acid battery as per OEM specification of Make: Exide New Express or equivelet.
S&F and testing of 180AH,12 Volt lead acid battery as per OEM specification of Make: Exide New Express or equivelet.
M&L for taking down complete engine and overhauling fully DG set and remove spare parts i.e. exhaust manifold assembly, water pump assembly,Radiator assembly, hose pipe for radiator and water pump,fan belt, dynamo belt , electric connection ,drain out old engine oil and replacement of unserviceable piston head assembly (06 Nos),cylinder head repair, liner, ring,gasket alongwith all accessories of DG set of Capacity 100 KVA and refixing the all parts after repair testing for DG set and running condition through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE (Note : Supply only accessories will be measured and paid separately):--
(a) Supply only Piston & Piston ring assembly (As per sample) or as per OEM specification
(b) Supply only Cylinder liner as per OEM specification
(c) Supply only CR bearing with cover (As per sample) or as per OEM specification
(d) Supply only Connecting Rod (As per sample or as per OEM specification
(e) Supply only Oil Cooler cartridge 10 plates along with gasket (As per sample) or as per OEM specification
(f) Supply only Engine Head Gasket (As per sample) or as per OEM specification
(g) Supply only Head servicing and testing valve and steel polishing as per OEM specification
M&L for taking down complete engine and overhauling fully DG set and remove spare parts i.e. exhaust manifold assembly, water pump assembly,Radiator assembly, hose pipe for radiator and water pump,fan belt, dynamo belt , electric connection ,drain out old engine oil and replacement of unserviceable piston head assembly (06 Nos),cylinder head repair, liner, ring,gasket alongwith all accessories of DG set of Capacity 30 KVA and refixing the all parts after repair testing for DG set and running condition through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE (Note : Supply only accessories will be measured and paid separately):--
(a) Supply only Piston & Piston ring assembly as per OEM specification
(b) Supply only Cylinder liner as per OEM specification
(c) Supply only CR bearing with cover as per OEM specification
(d) Supply only Connecting Rod as per OEM specification
(e) Supply only Engine Head Gasket (As per sample) or as per OEM specification
(f) Supply only Head servicing and testing valve and steel polishing as per OEM specification
(g) Supply only Crank shaft ball bearing (As per sample)or as per OEM specification
(h) Supply only fly wheel ring (AS per sample) or as per OEM specification
Dismantling self stratrer, DG set of capacity 400/250/125 /30 KVA, removing of Fly wheel from fly wheel assembly, and refixing after necessary repair including replacement of solenoid switch, gear assembly etc for the refixing the all parts after repair testing for DG set and running condition through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE(Note : Supply only accessories will be measured and paid separately):--
(a) Supply of fly wheel accessories as per OEM specification
M&L for filling of Distilled Water for Batttery as per OEM specification
Repair/Serviceing of External battery charger for DG set of 12/24 Volt 0 to 40 A capacity of any make through Authorised Original Equipment Manufacturer's Service Centre Engineers or through OEM Certified Agencies as approved by GE
I.S.ENTERPRISE
SUMAN CONSTRUCTION
Neha Enterprise
Guru Charan Mahata
Kalpana Traders
M/s Santosh Industrial Corporation
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .